HomeMy WebLinkAboutENGINEERING & TESTINGSCANNED By DATE: 4/18/18 CLIENT: ADDRESS PROJECT ADDRESS ENGINEERING & TESTING, INC. Phone: (866) 781-6889 o ai: (866) 784-8550 m,ww.tloridaengineeringandtesting.com 250 S.W.13`" Avenue Pompano Beach, FL 33669 JOB ORDER #: 18-1630 2017 FBC/ASCE-7 DESIGN PRESSURE CALCULATIONS Proiect Information: Height = 12' Exposure: C I Basic/Ultimate Wind Speed: V„it=170 mph Length = 46' Category: 1I I Nominal Wind Speed: V.d=Vint*�0.6 Width = 29' Slope: < 7° j (asd = allowable strength design) Parapet Wall: N/A Residential KZ = 0.85, Kzt = 1.0, Kd = 0.85 RECEIVED I Design Calculations: APR 20 2018 Velocity Pressure: q = 0.00256*K KZtKdV2 I ST. Lucie county, Permitting 1 P —0 00250 6 85 1 0 0 85 170 2= 53 45 f Ve ocrty ressure („ it). q— . ( . )(. I)( . )( ) . ps Velocity Pressure (.d): q=0.00256(0.85)(1.0)(0.85)(170*�0.6)2 = 32.07 psf I Width of Pressure Coefficient: 0.1(29) j = 2.9' 0.4(12') = 4.8' } use: 3'0" Effective Wind Area: <1 Oft2 j l For parapet height three feet (3') or larger,lzone three (3) shall be treated as zone two (2). External Pressure Coefficient: 1) GCP1 = -1.0 2) GCP2 = -1.8 3) GCP3 = -2.8 Internal Pressure Coefficient: 1) GCPi = 0.18 j Qriatitr/ ��\�� ✓lssrirance Page 2, 4/18/18, Job Order #L- -'�30 Tradewinds Roofing, Inc. Judy Stapleton Residence Flat Wood Non -Insulated Deck 1806 Linwood Avenue; Fort Pierce, FL: Design Pressures Based on Vsd: 1) Field P1 = 32.07*[(1.0) — (0.18)] = -37.8 psf 2) Perimeter P2 = 32.07*[(-1.8) — (0.18)] = -63.5 psf 3) Corners P3 = 32.07*[(-2.8) — (0.18)] = -95.6 psf Attachment Requirements Per RAS-117: Based on the requirements of Florida Product �pproval # FL1046-R8, Appendix 1, Page 6 of 22, System No. W-11, with a maximum design pressure of-52.5psf, the following are our recommended fastening patterns to attach the proposed two plies of PermaPly 28 or Ventsulation base sheet to the minimum 19/32I' plywood deck utilizing approved 11 ga. annular ring shank nails and 32ga., 1-5/8" diameter tin caps: Field: 9" o.c. @ 4" laps and 2 staggered rows 12" o.c. Perimeter: 9" o.c. @ 4" laps and 3 staggerel rows 9" o.c. Corners: 9" o.c. @ 4" laps and 4 staggered rows 9" o.c. Notes: Corners and perimeter area dimension shall not be less than a = TO" Contractor to verify that the fastening patterns meet manufacturer's requirements for issuance of a warranty (as applicable). All work shall be in compliance with the local building code product control notice of acceptance and manufacturer specifications and Florida Building Code 2017 Edition. Wind load calculations based on ASCE-7, 2017 FBC and information provided by client. Client is! responsible for verifying existing/proposed conditions/decks as it pertains to the above provided product approval. All work shall be inspected by our field engineer (or authorized representative) or a building l department inspector to verify compliance with specifications. M i 1 Y 66�®/�i NON Sincerely, ��'•, o /Vo , msryy � 9 1 Mark A. Mesiano, Florida Engineering Florida Reg. No. 48202�Z// L & Certificate of Authorization M.16 3