HomeMy WebLinkAboutPRODUCT APPROVAL ROOFING UNDERLAYMENTSFlorida Building Code Online SGANNEU Page 1 of 2
IP BY
71
BCtS Home ;Log In User Regis[ratlon i Hot Topics i Submit Surcharge I Stats & Facts i Publications i FBC Staff i. BCIS Site Map Links i Search
Flanda
°' ra Product
FUSER: Pub
Product Approval Menu > Product or Appijcation Sean
FL
Application Type
Code Version
Application Status
Comments
Archived
Approval
Ilc User
Product Manufacturer
Address/Phone/Email
Authorized Signature
Technical Representative
Address/Phone/Email
Quality Assurance Representative
Address/Phone/Email
Category
Subcategory
Compliance Method
> Application Detail
FL2569-R14
Revision
2017
Approved
Soprema, Inc. (Canada)
1640 rue Haggarty
Drummondville, NON -US 00000
(819)478-2400
memathieu@soprema. ca
Marc -Etienne Mathieu
memathieu@soprema.ca
Marc -Etienne Mathieu
1688 Jean-Berchmans-Michaud
Drummondville, NON -US 00000
(819) 478-2400 Ext3327
memathieu@soprema.ca
lean -Francois Cote, Ph.D.
1640 rue Haggarty
Drummondville
(888)811-3145
jfcote@soprema.ca
Roofing
Underlayments
RECEIVED
APR 20 2018
ST. Lucie County, Permitting
Evaluation Report from a Florida Registered Architect or a Licensed
Florida Professional Engineer
[ � Evaluation Report - Hardcopy Received
Florida Engineer or Architect Name who developed Robert 1. M. Nleminen
the Evaluation Report
Florida License
PE-59166
I
Quality Assurance Entity
UL LLC
Quality Assurance Contract Expiration Date
07/18/2020
Validated By I
John W. Knezevich, PE
'✓i Validation Checklist - Hardcopy Received
I
i
Certificate of Independence
I
Referenced Standard and Year (of Standard)
FL2569 R14 COI 2018 01 COI NIEMINEN_pdf
Standard
Year
ASTM D1970
2015
ASTM D4798
2011
ASTM D6163
2008
FM 4474
2011
FRSA/TRI April 2012 (04-12)
2012
UL1897
2012
httn://www.floridabuildin..org/pr/pr app dtl.aspx?param=wGEVXQwtDgsKQFEncicB10... 4/20/2018
Florida Building Code Online
i
Equivalence of Product Standards
Certified By
Sections from the Code
Product Approval Method
Date Submitted
Date Validated
Date Pending FBC Approval
Date Approved
Summary of Products
Method 1 Option D
02/12/2018
02/14/2018
02/17/2018
04/10/2018
Page 2 of 2
FL #
Model, Number or
Description
Name
2569.1
Soprema Roof
Self adhering roof underlayments
Underlayments
Limits of Use
Installation Instructions
Approved for use in HVHZ: No
FL2569 R14 IT-2018 02 FINAL ER SOPREMA CA UNDERLAYMEN] !j FL2,569-
R34 pdf
Approved for use outside HVHZ: Yes
Impact Resistant: N/A
Verified By: Robert Nieminen, P.E. PE-59166
Design Pressure: +N/A/-150
Created by Independent Third Party: Yes
Other: 1.) Refer to ER Section 5 for
Limits of Use. 2.) The design pressure
Evaluation Reports
FL2569 R14 AE 2018 02 FINAL ER SOPREMA CA UNDERLAYMENTS FL25A9
R14.pdf
noted herein pertains to underlayment
systems used beneath adhesive -set the
Created by Independent Third Party: Yes
systems. Refer to ER Section 5.6.4 for
details,
Back Next
Co tact Us : � 2601 Blair Stone Road Tallahassee FL 32399 Phone: 850-487-1824
The State of Florida is an AA/EEO employer. Convriobt 2007-2013 State of Florida.:: Privacy Statement:: Accessibility Statement.: Refund Statement
Under Florida law, email addresses are public records. If you do not want your e-mail address released In response to a public -records request, do not send
electronic mail to this entity. Instead, contact the office by phone or by traditional mall. If you have any questions, please contact 850.487.1395. 'Pursuant to
Section 455.275(1), Florida Statutes, effective October 1, 2012, licensees licensed under Chapter 455, F.S. must provide the Department with an email address if
they have one. The emails provided may be used for official communication with the licensee. However email addresses are public record. If you do not wish to
supply a personal address, please provide the Depa entwith an email address which can be made available to the public. To determine if you are a licensee under
Chapter 455, F.S., please click here .
Product Approval Accepts:
U 07ci
Credit Card
Safe
i
i
httt)://www.floridabuildin..orc/Dr/pr app idtl.aspx?param=wGEVXQwtDgsKQFEnckB 10... 4/20/2018
ENGINEER EVALUATE
Soprema, Inc.
1640 rue Haggerty
Drummondville, QuebecJ2C5P8 Canada
(819)478-2400
NEMO ! etc.
Certificate ofAuthorization #32455
353 Christian Street, Unit #13
Oxford, CT 06478
(203)262-9245
TEST CONSULT CERTIFY
Evaluation Report S18010.06.09-1112
FL2569-R14
Date of Issuance: 06/15/2009
Revision 12: 02/12/2018
SCOPE:
This Evaluation Report is issued under Rule 61G20-3 and the applicable rules and regulations governing the use of
construction materials in the State of Florida. The documentation submitted has been reviewed by Robert Nieminen,
P.E. for use of the product under the Florida B ilding Code and Florida Building Code, Residential Volume. The
products described herein have been evaluated I
for compliance with the 6th Edition (2017) Florida Building Code
sections noted herein.
DESCRIPTION: Soprema Roof Underlayments
LABELING: Labeling shall be in accordance with the requirements of the Accredited Quality Assurance Agency noted
herein.
CONTINUED COMPLIANCE: This Evaluation Report is valid until such time as the named product(s) changes, the referenced
Quality Assurance documentation changes, or provisions of the Code that relate to the product change. Acceptance of
this Evaluation Report by the named client constitutes agreement to notify Robert Nieminen, P.E. of any changes to
the product(s), the Quality Assurance or the production facility iocation(s). NEMO Ietc. requires a complete review of
this Evaluation Report relative to updated Code requirements with each Code Cycle.
ADVERTISEMENT: The Evaluation Report number preceded by the words "NEMO Ietc. Evaluated" may be displayed in
advertising literature. If any portion of the Evaluation Report is displayed, then it shall be done in its entirety.
INSPECTION: Upon request, a copy of this entire Evaluation Report shall be provided to the user by the manufacturer or
its distributors and shall be available for inspection at the job site at the request of the Building Official.
This Evaluation Report consists of pages 1 through
Prepared by:
�-ram ccia-:c.mc,..-..._�-,c-^.-•..,:-_
Robert J.M. Nieminen, P.E.
Florida Registration No. 59166, Florida DCA ANE1983
p'•._,� :: ?-� The facsimile seal appearing was authorized by Robert
�, S, c.• c Nieminen, P.E. on 02/12/2018. This does not serve as an
elearonically signed document
CERTIFICATION OF INDEPENDENCE:
1. NEMO ETC, LLC does not have, nor does it intend to acquire or will it acquire, a financial interest in any company manufacturing or
distributing products it evaluates.
2. NEMO ETC, LLC is not owned, operated or controlled by any company manufacturing or distributing products it evaluates.
3. Robert Nieminen, P.E. does not have nor will acquire, a financial interest in any company manufacturing or distributing products for
which the evaluation reports are being issued.
4. Robert Nieminen, P.E. does not have, nor will acquire, a financial interest in any other entity involved in the approval process of the
product.
5. This is a building code evaluation. Neither NEW Ietc. nor Robert Nieminen, P.E. are, in any way, the Designer of Record for any
project on which this Evaluation Report, or previous versions thereof, is/was used for permitting or design guidance unless retained
specifically for that purpose.
C�
MEMO etC.
ROOFING COMPONENT EVALUATION:
Product Category: Roofing
Sub -Category: Underlayment
Compliance Statement: Roof Underlaymeni , as produced by Soprema, have demonstrated compliance with the
following sections of the 6th Edition (2017) Florida Building Code through testing in accordance with the following
Standards. Compliance is subject to the Installation Requirements and Limitations / Conditions of Use set forth
herein.
Section
Pro e
Standard
Year
1504.3.1
I
Wind Resistance
FM 4474
2011
1504.3.1
Wind Uplift
UL 1897
2012
1507.2.4 / 1507.1.1, 1507.2.9.2
Physical Prope�ties
ASTM D1970
2015
1507.3.3
Physical Properties
FRSA/TRI April 2012
2012
FRSA/TRI April 2012 (04-12)
Physical Properties
ASTM D6163
2008
TAS 110
Accelerated Weathering
ASTM D4798
2011
Enti
Examination
Reference
Date
ERD (TST6049)
ASTM D1970%TAS 110
2968.05.04-2
05/14/2004
ERD (TST6049)
Physical Properties
2757.02.05
02/03/2005
ERD (TST6049)
ASTM D1970 % TAS 110
2974.03.05-2
05/17/2005
ERD (TST6049)
Wind Resistance
2778.07.05
07/15/2005
ERD (TST6049)
Wind Resistance
2779.11.05-131
04/18/2007
ERD (TST6049)
TAS 103 /TAS 110
57120.11.07-2
11/02/2007
ERD (TST6049)
ASTM D1970%TAS 110
S13190.02.09-111
04/01/2010
ERD (TST6049)
ASTM D19701/TAS 110
531370.03.10-1-R1
04/07/2010
ERD (TST6049)
Physical Properties / Tensile Adhesion
S11150.05.10-R1
09/09/2010
ERD (TST6049)
Physical Properties / Tensile Adhesion
S11150.05.09-R2
10/05/2010
ERD (TST6049)
ASTM D1970
S37210.11.11
11/09/2011
ERD (TST6049)
ASTM D1970I
S40540.02.13-1
02/19/2013
ERD (TST6049)
Physical Properties / Tensile Adhesion
S43530.02.14-1
02/21/2014
ERD (TST6049)
Physical Properties / Tensile Adhesion
SOPC-SC7645.02.15
02/13/2015
ERD (TST6049)
Accelerated
SOPC-SC8520.14
04/17/2015
ERD (TST6049)
(Weathering
Wind Resistance
SOPC-SC14045.05.17-RI
06/07/2017
M-D (CER1592)
HVHZ Compliance
15-0508.04
09/24/2015
ICC-ES (EVL2396)
2015 IBC Compliance
ESR-1524
03/01/2017
PRI (TST5878)
Physical Properties
SOP-064-02-01
12/03/2013
Soprema, Inc. (PDM3511)
EquivalencylDeclaration
SA SMOOTH PLY 40
06/29/2015
UL, LLC (QUA9625)
Quality Control
Service Confirmation
Exp.07/18/2020
1411 ' n u p" �,'. -� gp
77
��
4.1 Lastobond TU HT is a self -adhering,; non -woven polyester fabric surfaced, SBS modified bitumen roof
underlayment; meets ASTM D1970 and FRSA/TRI April 2012 (04-12).
4.2 Lastobond Shield is a self -adhering, woven polyethylene surfaced, SBS modified bitumen roof underlayment
available in two widths; 36 and 45 inch; i eets ASTM D1970.
4.3 RESISTO SA SMOOTH PLY 40 is a self -adhering, woven polyethylene surfaced, SBS modified bitumen roof
underlayment; available in 3.3 ft x 65 ft rolls; meets ASTM D1970.
4.4 Lastobond Shield HT is a self -adhering, woven polyethylene surfaced, high temperature, SBS modified bitumen roof
underlayment; meets ASTM D1970.
NEMO ETC, LLC i Evaluation Report 518010.06.09-R12
Certificate of Authorization #32455 6' EDITION (2017) FBC NON: HVHZ EVALUATION FL2569-1114
Soprema Roof Underlayments Revision 12: 02/12/2018
Page 2 of 8
I
4.5 Lastobond Pro HT-N is a self -adhering, woven polyethylene surfaced, SBS modified bitumen roof underlayment
available in two widths; 36 and 45 inch; meets ASTM D1970.
4.6 Lastobond Pro HT-S is a self -adhering, woven polyethylene surfaced, high temperature, SBS modified bitumen roof
underlayment; meets ASTM D1970.
4.7 EnviroShield is a self -adhering, woven po yethylene surfaced, high temperature, SBS modified bitumen roof
underlayment; meets ASTM D1970.
4.8 Lastobond 195 is a'self-adhering, glass -mat reinforced, sand -surfaced, SBS modified bitumen roof underlayment;
meets ASTM D1970.
4.9 Lastobond Eaves Protection Sheet is a self -adhering, glass -mat reinforced, sand -surfaced, SBS modified bitumen
roof underlayment; meets ASTM D1970.
4.10 Lastobond Eco is a self -adhering, glass -mat reinforced, sand -surfaced, SBS modified bitumen roof underlayment;
meets ASTM D1970.
4.11 Lastobond Smooth Seal HT is a self -adhering, glass -mat reinforced, film -surfaced, SBS modified bitumen roof
underlayment; meets ASTM D1970.
4.12 RESISTO LB1236 is a self -adhering, glass -mat reinforced, sand -surfaced, SBS modified bitumen roof underlayment,
with a 36-inch sheet width; meets ASTM D1970.
4.13 PrimeSource Grip -Rite Eave & Valley Protector is a self -adhering, glass -mat reinforced, sand -surfaced, SBS
modified bitumen roof underlayment, with a 36-inch sheet width; meets ASTM D1970.
4.14 RESISTO LB1244 is a self -adhering, glass-m�t reinforced, sand -surfaced, SBS modified bitumen roof underlayment,
with a 44-inch sheet width; meets ASTM D1970.
4.15 Colphene FR GR is a self -adhering, fiberglass reinforced, granule -surfaced, SBS modified bitumen roof
underlayment; meets ASTM D1970 and FRSA/TRI April 2012 (04-12).
5.1 This is a building code evaluation. Neither MEMO ETC, LLC nor Robert Nieminen, P.E. are, in any way, the Designer
of Record for any project on which this Evaluation Report, or previous versions thereof, is/was used for permitting
or design guidance unless retained specifici�lly for that purpose.
5.2 This Evaluation Report is not for use in FBC HVHZ jurisdictions.
5.3 Fire Classification is not part of this report; refer to current Approved Roofing Materials Directory for fire ratings of
this product.
5.4 Soprema Roof Underlayments may be used with any prepared roof cover where the product is specifically
referenced within FBC approval documents. If not listed, a request may be made to the Authority Having
Jurisdiction for approval based on this evaluation combined with supporting data for the prepared roof covering.
5.5 Allowable Roof Covers:
Wood or Slate or
Asphalt Nail -On Foam -On Composite
Underlayment Shingles Tile Tile Metal Shakes& Composite
Slate
Shingles
Lastobond TU HT Yes , Yes Yes Yes - Yes Yes
See '5.5 1
Lastobond Shield / Pro HT-N
RESISTO SA SMOOTH PLY 40 Yes No No No ,a . Yes. Yes
Lastobond Shield HT/ Pro HT-S Ye ~No No'.Yes - Yes, Yes
EnviroShield Yes , , No, _' No, Yes Yes
I
NEIMO ETC, LLC Evaluation Report 518010.06.09-R12
Certificate of Authorisation #32455 6' EDITION (2017) FBC NON-HVHZ EVALUATION FL2569-R14
Soprema Roof Underlayments Revision 12: 02/12/201.8
Page 3 of 8
Underlayment
Lastobond Eaves Protection Sheet /
Lastobond 195
Lastobond ECO / RESISTO LB1236,
Grip -Rite Eave & Valley Protector /
RESISTO LB1244
Lastobond Smooth Seal HT
Colphene FR GR
5.5.1 "Foam -On Tile" is limited to use of
Wood or
Slate or
Asphalt
Nail -On
Foam -On
Metal
Composite
Composite
Shingles
Tile
Tile
Shakes &
Slate
Shingles
Ye
;No ".
No
No
Yes
Yes.
f
'Yes
YeJ
No ... -
No
No
Yes .
No
'No
Yes'
Yes .:
Yes..
Yes --Yes
'Yes
No
Yes
;Yes
Sep,5.5 1
ollowine Approved tile adhesives / underlayment combinations.
71'q
Adhesive
Florida
Product Approval
Underlayments "
Dow TileBond'"
I FL22525
Lastobond TU HT
ICP Adhesives PolysetO AH-160
I FL6332
Lastobond TU HT or Colphene FR GR
5.6 Allowable Substrates:
5.6.1 Direct -Bond to Deck:
Lastobond Shield, Lastobond Pro HT-N RESISTO SA SMOOTH PLY 40, Lastobond Shield HT, Lastobond Pro HT-S,
EnviroShield, Lastobond TU HT, Lasto and Eaves Protection Sheet, Lastobond 195, Lastobond ECO, RESISTO
LB1236, Grip -Rite Eave & Valley Prote tor, RESISTO LB1244 or Lastobond Smooth Seal HT applied to:
➢ Plywood; ASTM D41 primed plyw000d; OSB; ASTM D41 primed OSB; Southern Yellow Pine; ASTM D41 primed
Southern Yellow Pine; ASTM D41 plrimed structural concrete.
Colphene FR GR applied to:
➢ Plywood; ASTM D41 primed plywood; ASTM D41 primed structural concrete.
N ote:
➢ While not required over plywood, OSB or Southern Yellow Pine substrates, Soprema recommends priming
with Elastocol Stick or Elastocol 600c if the final roof cover is not slated for installation within 24 hours.
➢ Soprema requires tongue -and -groove board decking be covered with plywood or OSB prior to installation of
the self -adhering underlayment.
5.6.2 Bond -to -Insulation:
Lastobond Shield, Lastobond Pro HT-N, RESISTO SA SMOOTH PLY 40, Lastobond Shield HT, Lastobond Pro HT-S,
EnviroShield, Lastobond TU HT, Lastobond Eaves Protection Sheet, Lastobond 195, Lastobond ECO, RESISTO
LB1236, Grip -Rite Eave & Valley Protector, RESISTO LB1244, Lastobond Smooth Seal HT or Colphene FR GR
applied to:
➢ Dens Deck Prime; SECU ROCK Gypsum -Fiber Roof Board.
For installation under mechanically attached prepared roof coverings, insulation shall be attached per minimum
requirements of the prepared roof covering manufacturer's Product Approval. For installations under foam -on
the systems (Lastobond TU HT only); insulation attachment shall be designed by a qualified design professional
and installed based on testing of the Iinsulation/underlayment system in accordance with FM 4474, Appendix D,
Testing Application Standard TAS 114, Appendix J or UL1807.
I
1 Refer to Tile Manufacturer's orAdhesive Manufacturer's Florida Product Approval for Overturning Moment Resistance Performance.
hIEMd ETC, LLC i Evaluation Report S18010.06.09-1112
Certificate of Authorization #32455 6- EDITION (2017) FBC NON-HVHZ EVALUATION FL2569-1114
Soprema Roof Underlayments Revision 12: 02/12/2018
Page 4 of 8
5.6.3
(104
N EMO 9 etc.
Lastobond Shield, Lastobond Pro HT-N, R' SISTO SA SMOOTH PLY 40, Lastobond Shield HT, Lastobond Pro HT-S,
EnviroShield, Lastobond TU HT, Lastobond Eaves Protection Sheet, Lastobond 195, Lastobond ECO, RESISTO
LB1236, Grip -Rite Eave & Valley Protectlor, RESISTO LB1244, Lastobond Smooth Seal HT or Colphene FR GR
applied to:
➢ ASTM D226, Type I or II felt; Sopra-G; Modified Sopra-G.
For installations under mechanically attac ed prepared roof coverings, base layer shall be attached per minimum
codified requirements. For installations under foam -on the systems (Lastobond TU HT only), base layer shall be
attached in accordance with FRSA/TRI April 2012 (04-12).
5.6.4 Wind Resistance for Underlayment Syster,ns in Foam -On Tile Applications: FRSA/TRI April 2012 (04-12) does not
address wind uplift resistance of all lunderlayment systems beneath foam -on the systems, where the
underlayment forms part of the load -pate. The following wind uplift limitations apply to underlayment systems
that are not addressed in FRSA/TRI April 2012 (04-12) and are used in foam -on tile applications. Maximum
Design Pressure is the result of testing for wind load resistance based on allowable wind loads, and reflects the
ultimate passing pressure divided by 2 (Ithe 2 to 1 margin of safety per FBC 1504.9 has already been applied).
Refer to FRSA/TRI April 2012 (04-12) or FBC 1609 for determination of design wind pressures.
#1 Maximum Design Pressure =-45.0 psf:
Deck: Min. 15/32-inch plywbod to meet project requirements to satisfaction of Authority Having
Jurisdiction.
Primer: (Optional) Elastocol Stick, Elastocol 600c or RESISTO EXTERIOR PRIMER
Underlayment: Lastobond TU HT or Colphene FR GR, self -adhered.
#2 Maximum Design Pressure = -67.5 psf:
Deck: Structural concrete L meet project requirements to satisfaction of Authority Having
Jurisdiction.
Primer: Elastocol600c
Underlayment: Lastobond TU HT or C Iphene FR GR, self -adhered.
#3 Maximum Design Pressure = -150.0 psf:
Deck: Min. 15/32-inch APA-rated BCX plywood (may be installed C-side up) to meet project
requirements to satisfaction of Authority Having Jurisdiction.
Deck Preparation: Plywood shall be thoroughly cleaned to remove dust and debris that may inhibit adhesion. All
sheathing fasteners shall be driven flush with the surface. All sharp splinters and wood
projections shall be removed sanded.
Primer: (Optional) RESISTO EXTERIOR PRIMER
Underlayment: Lastobond TU HT, self -adhered, shall be thoroughly roll using hand roller and/or weighted
roller to ensure there are no voids, and ensure there are no voids/bridging at side and end -
laps.
#4 Maximum Design Pressure =-60.0 psf:
Deck: Min. 19/32-inch plywood to meet project requirements to satisfaction of Authority Having
Jurisdiction.
Base Sheet: Sopra-G or Modified Sopra-G mechanically attached with nails (FBC 1517.5.1) and tin caps (FBC
1517.5.2) spaced 6-inch o.c. at the 4-inch laps and 6-inch o.c. in three (3), equally spaced rows
in the center of the sheet.
Underlayment: Lastobond TU HT or Colphene FR GR, self -adhered
5.6.4.1 All other direct -deck, adhered Soprema underlayment systems beneath foam -on tile systems carry a Maximum
Design Pressure of-45 psf.
i
MEMO ETC, LLC Evaluation Report 518010.06.09-1112
Certificate of Authorization #32455 6'" EDITION (2017) FBC PION-HVHZ EVALUATION FL2569-1114
Soprema Roof Underlayments Revision 12: 02/12/2018
Page 5 of 8
5.6.4.2 For mechanically attached Base Sheet, 1
exceed that required under FRSA/TRI Api
Alternatively, the maximum design press
pressure determined in accordance witl
density designed by a qualified design
methods are ANSI/SPRI WD1, FM Loss F
Assemblies marked with an asterisk* ca
Data Sheet 1-29 (January 2016) for Zone
5.7 Exposure Limitations:
Lastobond Eaves Protection Sheet, Lastc
Grip -Rite Eave & Valley Protector or R
installation.
5.8
i
I
I
Ie maximum design pressure for the selected assembly shall meet or
12012 (04-12), Appendix A, Table 1A.
are for the selected assembly shall meet or exceed the Zone 1 design
FBC 1609. In this case, Zones 2 and 3 shall employ an attachment
rofessional to resist the elevated pressure criteria. Commonly used
evention Data Sheet 1-29 and Roofing Application Standard RAS 117.
ry the limitations set forth in Section 2.2.10.1 of FM Loss Prevention
Y3 enhancements.
195,Lastobond Eco, Lastobond Smooth Seal HT, RESISTO LB1236,
I LB1244 shall not be left exposed for longer than 30-days after
Lastobond Shield, Lastobond Pro HT-N, ESISTO SA SMOOTH PLY 40, Lastobond Shield HT or Lastobond Pro HT-
S, EnviroShield shall not be left exposed for longer than 90-days after installation.
Lastobond TU HT or Colphene FR GR shall not be left exposed for longer than 180-days after installation.
When loading roof tiles on the underla Iment in direct -deck tile assemblies, the maximum roof slope shall be as
fn[IMAM Thpcp clnna limitations can only be exceeded by usine battens during loading of the roof tiles.
L
N.7.i�!?.R..°�FM�?"�-��e?+ t ,
Maximum
Underlayment
Tile Profile
Staging Method
Slope
I
Flat
Max. 10-tile stack
6:12
Lugged
Max. 10-tile stack
5:12
i
Max. 10-tile stack (bottom 2-tile stack
shall be inverted, followed by 8 tiles high
6:12
on slope, as shown below)
`'
Lastobond TU HT
p
Lugged
Flat
Max. 10-tile stack
5:12
Colphene FR GR
Lugged
I Max. 10-tile stack
6:12
MEMO ETC, LLC
Certificate of Authorization #32455
I
I
I
I.
i
i
6" EDIT�ON (2017) FBC NON-HVHZ EVALUATION
Soprema Roof Underlayments
i
I
Evaluation Report S18010.06.09-1112
FL2559-R14
Revision 12: 02/12/2018
Page 6 of 8
NEMOlet!
6.1 Soprema Roof Underlayments shall be in in accordance with Soprema published installation requirements
subject to the Limitations set forth in Section 5 herein and the specifics noted below.
6.2 Re -fasten any loose decking panels, andl check for protruding nail heads. Sweep the substrate thoroughly to
remove any dust and debris prior to application, and prime the substrate with Elastocol Stick, Elastocol 600c or
RESISTO EXTERIOR PRIMER (if applicable).1
6.3 Lastobond TU HT, Lastobond Shield,.. Lastobond Pro HT-N. RESISTO SA.SMOOTH PLY 40, Lastobond Shield HT,
Lastobond Pro HT-S, EnviroShield, Lastobi nd Eaves Protection Sheet, Lastobond 195; Lastobond Eco, Lastobond
Smooth Seal 1iT, RESISTO 1131235, Grip -Rite Eave & Valley,Protector, RESISTO.LR1244 or Colphene FIR GR,
6.3.1 Shall be installed in compliance with the requirements for ASTM D1970 underlayment in FBC Table 1507.1.1 for
the type of prepared roof covering to be installed.
6.3.2 Non -Tile Applications:
While priming is optional, Soprema reco mends priming with Elastocol Stick, Elastocol 600c or RESISTO EXTERIOR
PRIMER if the final roof cover is not slated for installation within 24 hours.
Apply sheet parallel to the roof edge. R II out approximately 10 ft of membrane and peel back the first 3 ft of
release film.
Adhere the exposed part to the substrate and unroll the remaining membrane as far as possible.
6.3.3
Once the entire length of membrane is in place, peel -off the release film diagonally while holding the membrane .
tight. Firmly roll the membrane into place to achieve a bond.
Horizontal seams should be minimum 3-inches, configured to shed water. Vertical seams should be 6-inches and
staggered not less than, 2-ft from vertical seams in the course below. All over -granule end -laps shall be sealed
using either heat -welding or hot air weldinng techniques.
When installing at slopes above 8:12, Soprema prema recommends back -nailing in the overlap area at the top of the
sheet at 12-inch o.c.
For Valleys and Ridges: Cut underlayment into 4 to 6 foot lengths. Peel the release paper and center sheet over
valley or ridge. Drape and press sheet into place, working from the center of the valley or ridge in each direction.
For valleys, apply the sheet starting at the lowest point and work upward.
Reference is made to FRSA/TRI April 2012 (04-12) Installation Manual and Table 1 herein, using the instructions
noted above as a guideline.
For foam -on tile applications, reference'is made to Section 5.6.4 herein for wind resistance limitations that fall
outside the scope of FRSA/TRI April 2012 (04-12).
Tile shall be loaded and staged in a manner that prevents tile slippage and/or damage to the underlayment. See
Table 2 herein, and Soprema published requirements for tile staging.
As required by the B
this product.
Official or Authority Having Jurisdiction in order to properly evaluate the installation of
NEViO ETC, LLC Evaluation Report S18010.06.09-1112
Certificate of Authorization #32455 6' EDITIOPl (2017) FBC NON-HVHZ EVALUATION FL2569-1114
Soprema Roof Underlayments Revision 12: 02/12/2018
1 Page 7 of 8
4
Contact the noted QA agency for information on product locations covered for F.A.C. 61G20-3 QA requirements.
The following plants have qualified products under their respective physical properties specifications.
Plant
Specification
Product(s)
Lastobond Shield, RESISTO SA SMOOTH PLY 40, Lastobond Shield HT,
Drummondville,
Lastobond Pro HT-N, Lastobond Pro HT-S, EnviroShield, Lastobond 195,
QC (Canada)
ASTM D1970
Lastobond Eaves Protection Sheet, Lastobond Eco, Lastobond Smooth
Seal HT, RESISTO LB1236, PrimeSource Grip -Rite Eave & Valley
Protector, RESISTO LB1244
ASTM D1970 & FRSA/TRI 041,12
Colphene FR GR
Lastobond 195, Lastobond Eaves Protection Sheet, Lastobond Eco,
Wadsworth, OH
ASTM D1970
Lastobond Smooth Seal HT, RESISTO LB1236, PrimeSource Grip -Rite
Eave & Valley Protector, RESISTO LB1244
ASTM D1970 & FRSA/TRl 04,L12
Lastobond TU HT; Colphene FR GR
Lastobond 195, Lastobond Eaves Protection Sheet, Lastobond Eco,
Gulfport, MS
ASTM D1970
Lastobond Smooth Seal HT, RESISTO LB1236, PrimeSource Grip -Rite
Eave & Valley Protector, RESISTO LB1244
UL, LLC—QUA9625; (314) 578-3406; k.chancellor@us.ul.com
NEMO ETC, LLC
Certificate of Authorization #32455
OF EVALUATION REPORT -
I
6' EDITION (2017) FBC NON-HVHZ EVALUATION
iSoprema Roof Underlayments
Evaluation Report S18010.06.09-R12
FL2569-R14
Revision 12:02112/2018
Page 8 of 8