Loading...
HomeMy WebLinkAboutPRODUCT APPROVAL METAL ROOFRECEI .Ipr;YY JM-V �. rr - MH APR 18 2018 BCIS Home i Log In j User RegistraI Submit S ha is & F P blications FBC Staff I BCIS Site Map Links ! Search . Lucieou`ny,ermiitg i Product Approval USER: Public User Product Approval Menu > Product or Application Search > Application List > Application Detail ST. LUCIE COUNTY BUILDING DIVISION REVIEWED FOR COMPLIAI�I4 FL # FL17022-R7 REVIEW D BY Application Type Revision DATE Code Version 2017 'PLANS AND PERM T MUST BE KEPT ON JOB Application Status Approved SITE OR NO INSPECTION(S) WILL BE MADE Comments 08/18/2017v. date reapply 08/21/17 Archived J Product Manufacturer Extreme Metal Fabricators, LLC Address/Phone/Email 2160 SW Poma Drive Palm City, FL 34990 (772) 872-8634 Flvalidation@yahoo.com Authorized Signature Richard McKuhen Flvalidation@yahoo.com Technical Representative Richard McKuhen Address/Phone/Email 2160 SW Poma Drive Palm City, FL 34990 (.772)872-8034 richard@emfab.net Quality Assurance Representative Address/Phone/Email F- E PLANS AND ALL PROPOSED WORK E SUBJECT TO ANY CORRECTIONS REQUIRED BY FIELD INSPECTORS THAT Category Roofing BE BE NECESSARY IN ORDER TO Subcategory Metal Roofing MIPLY WITH ALL APPLICABLE CODES. Compliance Method Evaluation Report from a Florida Registered Architect or a Licensed Florida Professional Engineer 17 Evaluation Report - Hardcopy Received Florida Engineer or Architect Name who developed LOCKE BOWDEN the Evaluation Report Florida License PE-49704 Quality Assurance Entity Keystone Certifications, Inc. Quality Assurance Contract Expiration Date 04/22/2024 Validated By Zachary R. Priest, P.E. 0 Validation Checklist - Hardcopy Received Certificate of Independence FL17022 R7 COI FL 17022.1 5 V CRIMP ssr.Ddf Referenced Standard and Year (of Standard) Standard TAS 125 UL 1897 UL 580 Equivalence of Product Standards Certified By Sections from the Code Year 2003 2012 2006 COPY �°" ARE THE RESPONSIBIILITY LED FASTENERS OR O THEENTS FILE CO - NTRACTOR OR RECORD Product Approval Method Date Submitted Date Validated Date Pending FBC Approval Date Approved Method 1 Option D 08/18/2017 O8/25/2017 08/28/2017 10/10/2017 FL # Model, Number or Name Description 17022.1 1 - "5V Crimp" (R6) 26 Gauge steel, 3/8" rib height, 24" wide lapped roof panel mechanically attached to 15/32" plywood or Wood Deck with fasteners Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes ImpactResistant: No Design Pressure: +N/A/ -Table A Other: Refer to evaluation report for conditions. Install the assembly in compliance with the Installation method listed In this report and applicable code sections of FBC. Refer to manufacturer's installation instructions. Installation Instructions FL17022 R7 II FL 17022.1 5 V CRIMP ssr.odf Verified By: Locke Bowden, P.E. 49704 Created by Independent Third Party: Yes Evaluation Reports FL17022 R7 AE_ FL 17022.1 5 V CRIMP ssr.odf Created by Independent Third Party: Yes 17022.2 2 - "5V Crimp" (R6) 0.032" Aluminum, 3/8" Rib height, 21" wide lapped roof panel, mechanically attached to 15/32" plywood or Wood Deck with exposed fasteners Limits of Use Installation Instructions Approved for use in HVHZ: No FL17022 R7 II FL 17022.2 5 V CRIMP 0.032 ALUM ssr.pdf Verified By: Locke Bowden, P.E. 49704 Approved for use outside HVHZ: Yes Impact Resistant: No Created by Independent Third Party: Yes Design Pressure: +N/A/ -Table A Evaluation Reports Other: Refer to evaluation report for conditions.Install the FL17022 R7 AE FL 17022.2 5 V CRIMP 0.032 assembly in compliance with the installation method listed in ALUM ssr.odf this report and applicable code sections of FBC. Refer to Created by Independent Third Party: Yes manufacturer's installation instructions. 17022.3 13 - "1.5" Mechanical Seam" (115) Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ.: Yes Impact Resistant: No Design Pressure: +N/A/ -Table A Other: Refer to evaluation report for conditions and limitations of use. Install the assembly in compliance with the installation method listed in this report and applicable code sections of FBC. Refer to manufacturer's installation instructions. 17022.4 14 - "1.5" 'Mechanical Seam" (115) Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: No Design Pressure: +N/A/ -Table A Other: Refer to evaluation report for conditions and limitations of use. Install the assembly in compliance with the installation method listed in this report and applicable code sections of FBC. Refer to manufacturer's installation instructions. 17022.5 15 - "1 in. Nail Strip" (115) Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: No Design Pressure: +N/A/ -Table A Other: Refer to evaluation report for conditions and limitations of use. Install the assembly In compliance with 1.5" rib height, 16" wide, 24 gauge steel, standing seam roof panel mechanically attached to 15/32" plywood or wood deck with clips and fasteners. Installation Instructions FL17022 R7 II FL 17022.3 1.5 MECHANICAL seam 24ga ssr.odf Verified By: Locke Bowden, P.E. 49704 Created by Independent Third Party: Yes Evaluation Reports FL17022 R7 AE FL 17022.3 1.5 MECHANICAL ;earn 240a ssr.odf Created by Independent Third Party: Yes 1.5" rib height, 16" wide, 0.032" aluminum, standing seam roof panel mechanically attached to 15/32" plywood or Wood Deck with clips and fasteners. Installation Instructions FL17022 R7 II FL 17022.4 MECHANCIAL SEAM ALUMINUM ssr.odf Verified By: Locke Bowden, P.E. 49704 Created by Independent Third Party: Yes Evaluation Reports FL17022 R7 AE FL 17022.4 MECHANCIAL_SEAM kLUMINUM ssr.odf Created by Independent Third Party: Yes 1" rib height, 16" wide, 26 gauge steel, standing seam roof panel mechanically attached to 15/32" plywood or wood deck with fasteners. Installation Instructions FL17022 R7 II FL 17022.5 1.0 NAILSTRIP ssr.odf Verified By: Locke Bowden, P.E. 49704 Created by Independent Third Party: Yes Evaluation Reports FL17022 R7 AE FL 17022.5_1.0 NAILSTRI_P_ ssr.pdf Created by Independent Third Party: Yes the installation method listed in this report and applicable code sections of FBC. Refer to manufacturer's installation instructions. 17022.6 16 - "1 in. Nail Strip" (115) Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: No Design Pressure: +N/A/ -Table A Other: Refer to evaluation report for conditions and limitations of use. Install the assembly in compliance with the installation method listed in this report and applicable code sections of FBC. Refer to manufacturer's installation instructions. 17022.7 17 - "1.5 In. Nail Strip" (115) Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: No Design Pressure: +N/A/ -Table A Other: Refer to evaluation report for conditions and limitations of use. Install the assembly in compliance with the installation method listed in this -report and applicable code sections of FBC. Refer to manufacturer's installation instructions. 17022.8 18 - "EMAX Rib" (R5) Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ': Yes Impact Resistant: No Design Pressure: +N/A/ -Table A Other: Refer to evaluation report for conditions and limitations of use. Install the assembly in compliance with the installation method listed in this report and applicable code sections of FBC. Refer to manufacturer's installation instructions. 17022.9 19 - " PBR MAX" (R5) Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: No Design Pressure: +N/A/ -Table A Other: Refer to evaluation report for conditions and limitations of use. Install the assembly in compliance with the installation method listed in this report and applicable code sections of FBC. Refer to manufacturer's installation Instructions. 1" rib height, 16" wide, 0.032" aluminum, standing seam roof panel mechanically attached to attached to 15/32" plywood or Wood Deck with fasteners, Installation Instructions FL17022 R7 II FL 17022.6 1.0 NAIL STRIP 0.032 ALUM ssr.Ddf Verified By: Locke Bowden, P.E. 49704 Created by Independent Third Party: Yes Evaluation Reports 1`1_17022 R7 AE FL 17022.6 1.0 NAIL STRIP 0.032 ALUM ssr.pdf Created by Independent Third Party: Yes 1.5" rib height, 19" wide, 26 gauge steel, standing seam roof panel mechanically attached to 15/32" plywood or wood deck with fasteners. Installation Instructions FL17022 R7 II FL 17022.7 1.5 Nail Strio 26GA ssr.odf Verified By: Locke Bowden, P.E. 49704 Created by Independent Third Party: Yes Evaluation Reports FL17022 R7 AE FL 17022.7 1.5 Nail Strip 26GA ssr.Ddf Created by Independent Third Party: Yes 29 gauge steel, lapped roof panel mechanically attached to 15/32" plywood or wood deck with exposed fasteners. Installation Instructions FL17022 R7 II FL 177022.8 EMAX Rib ssr,odf Verified By: Locke Bowden, P.E. 49704 Created by Independent Third Party: Yes Evaluation Reports FL17022 R7 AE FL 177022.8 EMAX Rib ssr.Ddf Created by Independent Third Party: Yes 26 gauge steel, lapped roof panel mechanically attached to 15/32" plywood or wood deck with exposed fasteners. Installation Instructions FL17022 R7 II FL 17022.9 PBR RIB ssr.Ddf Verified By: Locke Bowden, P.E. 49704 Created by Independent Third Party: Yes Evaluation Reports FL17022 R7 AE FL 17022.9 PBR RIB ssr.Ddf Created by Independent Third Party: Yes Bock Next Contact Us :: 2601 Blair Stone Road. Tallahassee FL 32399 Phone: 850-487-1824 The State of Florida Is an AA/EEO employer. Copyright 2007-2013 State of Florida, :: Privacy Statement :: Accessibility Statement :: Refund Statement Under Florida law, email addresses are public records. If you do not want your e-mail address released In response to a public -records request, do not send electronic mail to this entity. Instead, contact the office by phone or by traditional mail. If you have any questions, please contact 850.487.1395. -Pursuant to Section 455.275 (1), Florida Statutes, effective October 1, 2012, licensees licensed under Chapter 455, F.S. must provide the Department with an email address If they have one. The emails provided may be used for,offlcial communication with the licensee. However email addresses are public record. If you do not wish to supply a personal address, please provide the Department with an email address which can be made available to the public. To determine if you are a licensee under Chapter 455, F.S., please click bere . Product Approval Accepts: ®® ® r�- Credit Card Safe Palm City, FL 34990 Compliant with Florida Building Code 2017 (6t' ed.) Compliant with Florida Product Approval Rule # 61G20-3 Compliant: Keystone Certifications Product: 5 V Crimp 26GA Steel Roof Panel FBC Sec.1507.4.2 Yield strength: 50 ksi min.; Attached to min.15/32" plywood or Wood Deck w/ min. 0.42 specific gravity with screws. 24" Coverage Rib Height 3/8" Corrosion Resistant Compliant: FBC Sec.1507.4.3 Fastener 1(Method 1 Attachment): #9 x 1-1/2" Hex -Washer Head wood screw* to penetrate 3/16" min. thru deck or 5/8" embedment into wood plank. (*or sufficient length to meet requirements) Fastener 2 (Method 2,3, & 4 Attachment): #10 x 1-1/2" Hex -Washer Head wood screw* to -penetrate 3/16' min-. thru- deck or-5/8'embed ment-into-wood plank. -(*or sufficient length to meet requirements) Underlayment: To be compliant with FBC Sec. Chart 1507.1.1 Slope: Shall be in compliance with FBC Sec.1507. See Fastener attachment specifications above Install Details: Table A Allowable Loads METHOD 1 METHOD 2 METHOD 3 METHOD 4 DESIGN PRESSURE* -86 PSF -93.5 PSF -201 PSF -228 PSF ROW SPACING 16" ox. 16" o.c. 8" O.C. 6" o.c. FASTENER SPACING (ALONG Panel width) 12" o.c. 12" ox. 12" o.c. 12" o.c. FASTENER SIZE 1 #9 #10 #10 #10 Reference Data: ARCHITECTURAL TESTING, INC. TST ID#: 1527 UL 580-06 & 1897-041 Test Report CC5893.01-450-18 05/02/14 Test Report F3366.01-450-18 12/18/15 TAS 125-03 Test Report D05893.02-450-18 07/22/14 *EQUIVALENCY-UL 1897-04 is equivalent to test standard UL 1897-1? *Design pressure margin of safety 2:1 ..11 inn►... `tip-�`tC,�• L'Q`,����/r Locke Bowden, P.E. does not have, not will acquire a financial in lq a �cq •, ` 4 m.%facturing or distributing products under this evaluation. :� �•y • ` 'Z Locke Bowden, P.E. is not owned, operated, or controlled by al2y comparNo nibiliatturer, or distributing products under this report. • l Jam•-/� � ;. e ���� S r Tc : �4 V-1;7/7 ' FL17022.1 5V G' p (26GA Steel), 24" Wide Roof PI Details Limitations: 1. Und.,rlayment to be compliance with current FloridaBuilding Code (FBC)2017 6th ed. 2. Minimum slope to be compliant with Florida Building Code 2017 6th ed., and per with Manufacturer's installation reference. 3. Products are compliant for State of Florida product approval per Rule 61 G20-3. Compliance Method: 1-D 4. Engineering analysis for "project specific approval by local authorities w/jurisdiction is allowed by other registered engineers. 5. Fire classification is not part of this acceptance. Shear diaphragm values are outside this report. 6. Support framing in compliance w/FBC 2017 6th ed., Chapter 22 for Steel, Chapter 23 for Wood and Chapter 16 for Structural Loading. 7. This report does not imply warranty, installation, recommended product use outside of this report. Fasteners - #9 x 1-1/2" Min. or #10 x 1-1/2" Min. perTab/e A" for Row Spacing and Design Pressures Hex Washer Head Wood Screws 5-V Crimp Roof Panel — Deck: -15/32" or greater Plywood, or -Vftd.plank. - - -- - - - - - - - 14" OPTIONAL STRIATIONS Panel Profile Nominal12" Nominal12" O.C. O.C. Fasten E9 X 1-1/2" Min. or' #10 X 1-1/2" Min. per -fable "A" Hex Washer Head Screw Spaced 12" o.c. across the Panel VVdth Panel Refer to Table "A" for Spacing Along Panel Overlap Length Deck-15/32" or greater Plywood, or - Wood plank