HomeMy WebLinkAboutENERGY EFFICIENCY CODESGANNFL
R
V
FORM R405-2017 �'
EISERG 'P�ERAORMANCE LEVEL (EPL)
DISPLAY CARD
ESTIMATED ENERGY PERFORMANCE INDEX* = 72
The lower the EnergyPerformance Index, the more efficient the home.
210 N BROCKSMITHI� ROAD, FORT PIERCE, FL,
I
1. New construction or existing New (From Plans) i 9. Wall Types Insulation
2. Single family or multiple family Single-family a. Frame - Wood, Exterior R=19.0
I b. N/A R=
3. Number of units, if multiple family 1 c N/A R-
4. Number of Bedrooms 1
5. Is this a worst case? No
6. Conditioned floor area (ftz) 960
7. Windows*"
Description
a. U-Factor:
Sgl, U=0.65
SHGC:
SHGC=0.25
b. U-Factor:
Sgl, U=0.70
SHGC:
SHGC=0.30
c. U-Factor.
N/A
SHGC:
d. U-Factor:
N/A
SHGC:
Area Weighted Average Overhang Depth:
Area Weighted Average SHGC:
8. Floor Types
Insulation
a. Slab -On -Grade Edge Insulation
R=0.0
b. N/A
R=
c. N/A
R=
Area
70.00 ftz
48.00 ftz
ftz
ftz
1.500 ft.
0.270
Area
960.00 ftz
ftz
ftz
d. N/A
10. Ceiling Types
a. Roof Deck (Unvented)
b. NIA
c. N/A
11. Ducts
12. Cooling systems
a. Central Unit
b. Central Unit
13. Heating systems
a. Electric Heat Pump
b. Electric Heat Pump
14. Hot water systems
a. Electric
b. Conservation features
None
15. Credits
I .certify that this home has complied with the Florida Energy Efficiency Code for Building
Construction through the above energy saving features which will be installed (or exceeded)
in this home before final inspection. Otherwise, a new EPL Display Card will be completed
based on installed Code compliant features.
Builder Signature:
Address of New Home:
Date:
City/FL Zip:
R=
Insulation
R=20.0
R=
R=
Area
1536.00 ftz
ftz
ftz
ftz
Area
960.00 ftz
ftz
ftz
R ftz
kBtu/hr Efficiency
10.9 SEER:19.00
9.0 SEER:19.00
kBtu/hr Efficiency
17.0 HSPF:9.00
17.0 HSPF:9.00
Cap: 40 gallons
EF: 0.98
None
*Note: This is not a Building Energy Rating. If your Index is below 70, your home may qualify for energy efficient
mortgage (EEM) incentives if you obtain a Florida EnergyGauge Rating. Email EnergyGauge tech support at
techsupport@energygauge.com or see the EnergyGauge web site at energygauge.com for information and a list of
certified Raters. For information about the Florida' Building Code, Energy Conservation, contact the Florida Building
Commission's support staff.
**Label required by Section R303.1.3 of the Florida Building Code, Energy Conservation, if not DEFAULT.
5/16/2018 3:22 PM EnergyGauge® USA - FlaRes2017 - Section R405.4.1 Compliant Software Page 1 of 1
2017 - AIR BARRIER AND INSULATION INSPECTION COMPONENT CRITERIA
TABLE 402.4.1.1
AIR BARRIER AND INSULATION INSPECTION COMPONENT CRITERIA
Project Name: PREVO GUEST HOUSE Builder Name:
Street: 210 N BROCKSMITH ROAD Permit Office: ST LUCIE COUNTY
City, State, Zip: FORT PIERCE, FL, Permit Number:
Owner: Jurisdiction: ST LUCIE COUNTY
Design Location: FL, Fort Pierce
COMPONENT
AIR BARRIER CRITERIA
INSULATION INSTALLATION CRITERIA
General
A continuous air barrier shall be installed in the building envelope.
Air -permeable insulation shall
requirements
The exterior thermal envelope contains a continuous air barrier.
Breaks or joints in the air barrier shall be sealed.
not be used as a sealing material.
Ceiling/attic
The air barrier in any dropped ceiling/soffit shall be aligned with the
The insulation in an dropped ceilin /soffit
g
insulation and any gaps in the air barrier shall be sealed.
Access openings, drop down stairs or knee wall doors to
shall be aligned with the air barrier.
unconditioned attic spaces.shall be sealed.
Walls
The junction of the foundation and sill plate shall be sealed.
Cavities within corners and headers of frame walls shall
The junction of the top plate and the top of exterior walls shall be sealed.
be insulated by completely filling the cavity with a
Knee walls shall be sealed.
material having a thermal resistance of R-3 per inch
minimum.
Exterior thermal envelope insulation for framed walls
shall be installed in substantial contact and continuous
alignment with the air barrier.
Windows, skylights
The space between window/doorjambs and framing, and
and doors
skylights and framing shall be sealed.
Rim joists
Rim joists shall include the air barrier.
Rim joists shall be insulated.
Floors
The air barrier shall be installed at any exposed, edge of insulation.
Floor framing cavity insulation shall be installed to
(including
maintain permanent contact with the underside of
above -garage
subfloor decking, or floor framing cavity insulation shall
and cantilevered floors)
be permitted to be in contact with the op side of
sheathing, or continuous insulation installed on the
underside of floor framing and extends from the bottom
to the top of all perimeter floor framing members.
Crawl space walls
Exposed earth in unvented crawl spaces shall be covered with a
Where provided instead of floor insulation, insulation
Class I vapor retarder with overlapping joints taped.
shall be permanently attached to the crawispace walls.
Shafts, penetrations
Duct shafts, utility penetrations, and flue shafts opening to exterior
or unconditioned s ace shall be sealed. .
Batts in narrow cavities shall be cut to fit, or narrow
Narrow cavities
cavities shall be filled by insulation that on installation
readily conforms to the available cavity spaces.
Garage separation
Air sealing shall be provided between the garage and conditioned spaces.
r
Recessed lighting
Recessed light fixtures installed in the building thermal envelope shall
Recessed light fixtures installed in the building
be sealed to the drywall.
thermal envelope shall be air tight and IC rated.
Plumbing and wiring
Batt insulation shall be cut neatly to fit around wiring and
plumbing in exterior walls, or insulation that on
installation readily conforms to available space shall
extend behind Pioing and wiring,
Shower/tub
The air barrier installed at exterior walls adjacent to showers and
Exterior walls adjacent to showers and tubs shall be
on exterior wall
tubs shall separate them from the showers and tubs.
insulated.
Electrical/phone box on
The air barrier shall be installed behind electrical or communication
exterior walls
boxes or air -sealed boxes shall be installed.
HVAC register boots
HVAC register boots that penetrate building thermal envelope shall be
sealed to the sub -floor or drywall.
Concealed
When required to be sealed, concealed fire sprinklers shall only be sealed
sprinklers
in a manner that is recommended by the manufacturer. Caulking or other
adhesive sealants shall not be used to fill voids between fire sprinkler
cover plates and Walls or ceilings.
a. lie ILIvu, II IOrJGGUUII UI ivy wdus snap ue In accoruance wan me;prowsions or icu-4uu. .,
5/16/2018'3:22 PM EnergyGaugeO USA - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 1 of 1
4.
FORM R405-2017
FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION
Florida Department of Business and Professional Regulation - Residential Performance Method
Project Name: PREVO GUEST HOUSE
Builder Name:
Street: 210 N BROCKSMITH ROAD
Permit Office: ST LUCIE COUNTY
City, State, Zip: FORT PIERCE, FL,
Permit Number:
Owner:
Jurisdiction: ST LUCIE COUNTY
Design Location: FL, Fort Pierce
County:: St. Lucie (Florida Climate Zone 2 )
1. New construction or existing New (From Plans)
9. Wall Types (1536.0 sqft.)
Insulation Area
2. Single family or multiple family Single-family
a. Frame - Wood, Exterior
R=19.0 1536.00 f?
3. Number of units, if multiple family 1
b. N/A
R= ft2
c. N/A
R= f124.
Number of Bedrooms 1
d. N/A
R= ft'
5. Is this a worst case? No
10. Ceiling Types (960.0 sgft.)
Insulation Area
6. Conditioned floor area above grade (W) 960
a. Roof Deck (Unvented)
b. N/A
R=20.0 960.00 f12
R= ff'
Conditioned floor area below grade (f?) 0
c. N/A
R= ft2
7. Windows(118.0 sgft.) Description Area
11. Ducts
R f12
a. U-Factor: Sgl, U=0.65 70.00 ft2
SHGC: SHGC=0.25
b. U-Factor: SgI, U=0.70 48.00 ft2
12. Cooling systems
kBtu/hr Efficiency
SHGC: SHGC=0.30
a. Central Unit
10.9 SEER:19.00
c. U-Factor: N/A f12
b. Central Unit
9.0 SEER:19.00
SHGC:
d. U-Factor: N/A ft2
13. Heating systems
kBtu/hr Efficiency
SHGC: I
a. Electric Heat Pump
17.0 HSPF:9.00
b. Electric Heat Pump
17.0 HSPF:9.00
Area Weighted Average Overhang Depth: 1.500 ft.
Area Weighted Average SHGC: 0.270
14. Hot water systems
8. Floor Types (960.0 sgft.) Insulation Area
a. Electric
Cap: 40 gallons
a. Slab -On -Grade Edge Insulation R=0.0 960.00 ft'
b. Conservation features
EF: 0.980
b. N/A R= ft2
None
c. N/A R= ft2
15. Credits
None
Glass/Floor Area: 0.123 Total Proposed Modified Loads: 28.29
PASS
S
Total Baseline Loads: 39.56
I hereby certify that the plans and specifications covered by
Review of the plans and
this calculation are in compliance with the Florida Energy
specifications covered by this
Code.
calculation indicates compliance
A.
co.�,'%''� -��o� A+
with the Florida Energy Code.
PREPD BY:
Before
e construction is completed
DATE:
this building will be inspected for
compliance with Section 553.908
I hereby certify that this building, as designed, is in compliance
Florida Statutes.
1� «
with the Florida Energy Code.
C0D WE
OWNER/AGENT'
BUILDING OFFICIAL:
DATE:
DATE:
- Compliance requires certification by the air handler unit manufacturer that the air handler enclosure qualifies as
certified factory -sealed in accordance with R403.3.2.1.
- Compliance requires an Air Barrier and Insulation Inspection Checklist in accordance with R402.4.1.1 and this project requires
an envelope leakage test report with envelope leakage no greater than 7.00 ACH50 (11402.4.1.2).
5/16/2018 3:22 PM EnergyGauge® USA - FlaRes2017 Section R405.4.1 Compliant Software Page 1 of 5
FORM R405-2017
PROJECT
Title: PREVO GUEST HOUSE Bedrooms: 1
Address Type:
Street Address
Building Type: User
Conditioned Area: 960
Lot #
Owner Name:
Total Stories: 1
Block/Subdivision:
# of Units: 1
Worst Case: No
PlatBook:
Builder Name:
Rotate Angle: 0
Street:
210 N BROCKSMITH R
Permit Office: ST LUCIE COUNTY
Cross Ventilation: No
County:
St. Lucie
Jurisdiction: ST LUCIE COUNTY
Whole House Fan: No
City, State, Zip:
FORT PIERCE,
Family Type: Single-family
FL.
New/Existing: New (From Plans)
Comment:
CLIMATE
/
Design Temp
Int Design Temp Heating
Design Daily Temp
V Design Location
TMY Site 97.5 % 2.5 %
Winter
Summer Degree Days Moisture
Range
FL, Fort Pierce FL VERO BEACH_MUNI , 39 90
70
75 299
62
Low
BL06KS
Number Name
Area Volume
1 .MINISPLIT 1
648 8876
2 MINISPLIT 2
312 3120
SPACES
Number Name
Area Volume Kitchen Occupants
Bedrooms
InfilID Finished Cooled
Heated
1 KITCHEN
180 2520 Yes 0
1 Yes
Yes
Yes
2 UTILITY
49 490 No 0
1 Yes
Yes
Yes
3 GREAT ROOM
419 5866 No 0
1 Yes
Yes
Yes
4 TOILET
24 240 No I 0
1 Yes
Yes
Yes
5 CLST
18 180 No 0
1 No
Yes
Yes
6 BEDROOM
169 1690 No 0
1
1 Yes
Yes
Yes
7 BATH
101 1010 No 0
1 Yes
Yes
Yes
FLOORS �
# Floor Type
Space Perimeter PerimeteriR-Value
Area
Joist R-Value
Tile Wood
Carpet
1 Slab -On -Grade Edge Insulation
KITCHEN 27 ft 0 i
180 ft2
___-
1 0
0
2 Slab -On -Grade Edge Insulation
UTILITY 14 ft 0'
49 ft2
___
1 0
0
3 Slab -On -Grade Edge Insulation
GREAT ROOM 37 ft 0
419 ft2
_---
1 0
0
4 Slab -On -Grade Edge Insulation
TOILET 6 ft 0
24 ft2
1 0
0
5 Slab -On -Grade Edge Insulation
CLST 1 ft 0
18 ft2
----
1 0
0
6 Slab -On -Grade Edge Insulation
BEDROOM 26 ft 0
169 ft2
____
1 0
0
7Slab-On-Grade Edge Insulation
BATH 18 ft 0
101 ft2
___-
1 0
0
5/16/2018 3:22 PM EnergyGaugeO USA - FlaRes2017 Section R405.4.1 Compliant Software Page 2 of 5
FORM R405-2017
ROOF
/
Roof
Gable
Roof
Solar SA
Emitt
Emitt
Deck
Pitch
V
#
Type Materials Area
Area
Color
Absor. Tested
Tested
Insul.
(deg)
1
Gable or Shed Composition shingles 1154 ft2
320 ftz
Medium
0.6
No
0.9
No
20
33.7
AtTIC
#
Type
Ventilation
Vent Ratio (1 in) Area
RBS
IRCC
1
Full attic
Unvented
0
960 ft2
N
N
CEILING
#
Ceiling Type
Space
R-Value
Ins Type
Area
Framing Frac Truss Type
1
Under Attic (Unvented)
KITCHEN
20
Blown
180 ft2
0.1
Wood
2
Under Attic (Unvented)
UTILITY
20
Blown
49 ft2
0.1
Wood
3
Under Attic (Unvented)
GREAT ROOM
20
Blown
419 ft2
0.1
Wood
4
Under Attic (Unvented)
TOILET
20
Blown
24 ft2
0.1
Wood
5
Under Attic (Unvented)
CLST
20
Blown
18 ft2
0.1
Wood
6
Under Attic (Unvented)
BEDROOM
20
Blown
169 ft2
0.1
Wood
7
Under Attic (Unvented)
BATH
20
Blown
101ft2
0.1
Wood
WALLS
Adjacent
Space
Cavity Width Height
Sheathing Framing
Solar
Below
0
- 1
S
Exterior Frame - Wood
KITCHEN
19 15
0 14
0
210.0 ft2
0
0
0.6
0
_ 2
W
Exterior Frame - Wood
KITCHEN
19 12
0 14
0
168.0 ft2
0
0
0.6
0
3
N
Exterior Frame- Wood
UTILITY
19 7
0 10
0
70.0 ft2
0
0
0.6
0
_ 4
W
Exterior Frame - Wood
UTILITY
19 7
0 10
0
70.0 ft2
0
0
0.6
0
_ 5
N
Exterior Frame - Wood
GREAT ROO
19 20
0 14
0
280.0 ft2
0
0
0.6
0
6
S
Exterior Frame - Wood
GREAT ROO
19 12
0 14
0
168.0 ft2
0
0
0.6
0
_ 7
W
Exterior Frame - Wood
GREAT ROO
19 5
0 14
0
70.0 f12
0
0
0.6
0
_ 8
E
Exterior Frame - Wood
TOILET
19 6
0 10
0
60.0 ft2
0
0
0.6
0
9
E
Exterior Frame - Wood
BEDROOM
19 13
0 10
0
130.0 ft2
0
0
0.6
0
_ 10
S
Exterior Frame - Wood
BEDROOM
19 13
0 10
0
130.0 ft2
0
0
0.6
0
_ 11
N
Exterior Frame - Wood
BATH
19 13
0 10
0
130.0 ft2
0
0
0.6
0
_ 12
E
Exterior Frame - Wood
BATH
19 5
0 10
0
50.0 ft2
0
0
0.6
0
DOORS
#
Ornt Door Type
Space
Storms
U-Value Width
Height
Area
Ft
In
Ft In
1
W Insulated
GREAT ROO
None
.39
3
8
24 ft2
6/16/2018 3:22 PM EnergyGaugeO USA - FlaRes2017 Section R405.4.1 Compliant Software Page 3 of 5
FORM R405-2017
WINDOWS
Orientation shown is the entered, Proposed orientation.
/
Wall
Overhang
V/ #
Ornt ID Frame Panes
NFRC
U-Factor SHGC Imp Area Depth Separation
Int Shade
Screening
1
S 1 Metal Low-E Single
Yes
0.65 0.25 N 12.0 ft2 1 ft 6 in 1 ft 4 in
None
None
2
W 2 Metal Low-E Single
Yes
0.65 0.25 N 18.0 ft2 1 ft 6 in 1 ft 4 in
None
None
3
S 6 Metal Low-E Single
Yes
0.7 0.3 N 48.0 ft2 1 ft 6 in 1 ft 4 in
None
None
4
W 7 Metal Low-E Single
Yes
0.65 0.25 N 18.0 ft2 1 ft 6 in 1 ft 4 In
None
None
5
S 10 Metal Low-E Single
Yes
0.65 0.25 N 18.0 ft2 1 ft 6 in 1 ft 4 in
None
None
6
E 12 Metal Low-E Single
Yes
0.65 0.25 N 4.0 ft2 1 ft 6 in 1 ft 4 in
None
None
INFILTRATION
# Scope
Method
SLA
CFM 50 ELA EgLA ACH ACH 50
1 Wholehouse Proposed ACH(50)
.000556
1399.5 76.83 144.49 .4057
7
HEATING SYSTEM
#
System Type
Subtype
Efficiency Capacity
Block
Ducts
1
Electric Heat Pump/
Split
HSPF:9 17 kBtu/hr
1
Ductless
2
Electric Heat Pump/
Split
HSPF:9 17 kBtu/hr
2
Ductless
COOLING SYSTEM
#
System Type
Subtype
Efficiency Capacity Air Flow
SHR Block
Ducts
1
Central Unit/
Split
SEER: 19 10.9 kBtu/hr 327 cfm
0.8 1
Ductless
2
Central Unit/
Split
SEER: 19 9 kBtu/hr 270 cfm
0.8 2
Ductless
HOT WATER SYSTEM
#
System Type SubType
Location
EF Cap Use SetPnt
Conservation
1
Electric None
UTILITY
0.98 40 gal 60.9 gal 120 deg
None
SOLAR HOT WATER SYSTEM
FSEC
Collector
Storage
Cert # Company Name
System Model # Collector Model # Area
Volume
FEF
None None
ft2
5116/2018 3:22 PM EnergyGauge® USA - FlaRes2017 Section R405.4.1 Compliant Software Page 4 of 5
FORM R405
TEMPERATURES
Programable Thermostat: N
Ceiling Fans:
Cooling Jan
VentinJan
Feb
Feb
Mar
?CMar
Apr
Apr
May 1
May
X Jun
Jun
Jul
Jul
Aug
Aug
Se
Sep
Oct
OctX
Nov
Nov
Dec
Dec
Jun
[ Jul
[ Aug
Sep
Thermostat Schedule:
HERS 2006 Reference
Hours
Schedule Type
1
2
3
4
5
6
7
8
9
10
11
12
Cooling (WD)
AM
78
78
78
78
78
78
78
78
80
80
80
80
PM
80
80
80
80
78
78
78
78
78
78
78
78
Cooling (WEH)
AM
PM
78
80
78
80
78
80
78
80
78
78
78
78
78
78
80
80
80
80
78
78
78
78
78
78
Heating (WD)
AM
PM
65
68
65
68
65
68
65
68
65
68
65
68
65
68
68
68
68
68
68
68
68
68
68
68
Heating (WEH)
AM
65
65
65
65
65
65
65
68
68
68
68
68
PM
68
68
68
68
68
68
68
68
68
68
68
68
I
5/16/2018 3:22 PM EnergyGauge® USA - FlaRes2017 Section R405.4.1 Compliant Software