Loading...
HomeMy WebLinkAboutENERGY EFFICIENCY CODESGANNFL R V FORM R405-2017 �' EISERG 'P�ERAORMANCE LEVEL (EPL) DISPLAY CARD ESTIMATED ENERGY PERFORMANCE INDEX* = 72 The lower the EnergyPerformance Index, the more efficient the home. 210 N BROCKSMITHI� ROAD, FORT PIERCE, FL, I 1. New construction or existing New (From Plans) i 9. Wall Types Insulation 2. Single family or multiple family Single-family a. Frame - Wood, Exterior R=19.0 I b. N/A R= 3. Number of units, if multiple family 1 c N/A R- 4. Number of Bedrooms 1 5. Is this a worst case? No 6. Conditioned floor area (ftz) 960 7. Windows*" Description a. U-Factor: Sgl, U=0.65 SHGC: SHGC=0.25 b. U-Factor: Sgl, U=0.70 SHGC: SHGC=0.30 c. U-Factor. N/A SHGC: d. U-Factor: N/A SHGC: Area Weighted Average Overhang Depth: Area Weighted Average SHGC: 8. Floor Types Insulation a. Slab -On -Grade Edge Insulation R=0.0 b. N/A R= c. N/A R= Area 70.00 ftz 48.00 ftz ftz ftz 1.500 ft. 0.270 Area 960.00 ftz ftz ftz d. N/A 10. Ceiling Types a. Roof Deck (Unvented) b. NIA c. N/A 11. Ducts 12. Cooling systems a. Central Unit b. Central Unit 13. Heating systems a. Electric Heat Pump b. Electric Heat Pump 14. Hot water systems a. Electric b. Conservation features None 15. Credits I .certify that this home has complied with the Florida Energy Efficiency Code for Building Construction through the above energy saving features which will be installed (or exceeded) in this home before final inspection. Otherwise, a new EPL Display Card will be completed based on installed Code compliant features. Builder Signature: Address of New Home: Date: City/FL Zip: R= Insulation R=20.0 R= R= Area 1536.00 ftz ftz ftz ftz Area 960.00 ftz ftz ftz R ftz kBtu/hr Efficiency 10.9 SEER:19.00 9.0 SEER:19.00 kBtu/hr Efficiency 17.0 HSPF:9.00 17.0 HSPF:9.00 Cap: 40 gallons EF: 0.98 None *Note: This is not a Building Energy Rating. If your Index is below 70, your home may qualify for energy efficient mortgage (EEM) incentives if you obtain a Florida EnergyGauge Rating. Email EnergyGauge tech support at techsupport@energygauge.com or see the EnergyGauge web site at energygauge.com for information and a list of certified Raters. For information about the Florida' Building Code, Energy Conservation, contact the Florida Building Commission's support staff. **Label required by Section R303.1.3 of the Florida Building Code, Energy Conservation, if not DEFAULT. 5/16/2018 3:22 PM EnergyGauge® USA - FlaRes2017 - Section R405.4.1 Compliant Software Page 1 of 1 2017 - AIR BARRIER AND INSULATION INSPECTION COMPONENT CRITERIA TABLE 402.4.1.1 AIR BARRIER AND INSULATION INSPECTION COMPONENT CRITERIA Project Name: PREVO GUEST HOUSE Builder Name: Street: 210 N BROCKSMITH ROAD Permit Office: ST LUCIE COUNTY City, State, Zip: FORT PIERCE, FL, Permit Number: Owner: Jurisdiction: ST LUCIE COUNTY Design Location: FL, Fort Pierce COMPONENT AIR BARRIER CRITERIA INSULATION INSTALLATION CRITERIA General A continuous air barrier shall be installed in the building envelope. Air -permeable insulation shall requirements The exterior thermal envelope contains a continuous air barrier. Breaks or joints in the air barrier shall be sealed. not be used as a sealing material. Ceiling/attic The air barrier in any dropped ceiling/soffit shall be aligned with the The insulation in an dropped ceilin /soffit g insulation and any gaps in the air barrier shall be sealed. Access openings, drop down stairs or knee wall doors to shall be aligned with the air barrier. unconditioned attic spaces.shall be sealed. Walls The junction of the foundation and sill plate shall be sealed. Cavities within corners and headers of frame walls shall The junction of the top plate and the top of exterior walls shall be sealed. be insulated by completely filling the cavity with a Knee walls shall be sealed. material having a thermal resistance of R-3 per inch minimum. Exterior thermal envelope insulation for framed walls shall be installed in substantial contact and continuous alignment with the air barrier. Windows, skylights The space between window/doorjambs and framing, and and doors skylights and framing shall be sealed. Rim joists Rim joists shall include the air barrier. Rim joists shall be insulated. Floors The air barrier shall be installed at any exposed, edge of insulation. Floor framing cavity insulation shall be installed to (including maintain permanent contact with the underside of above -garage subfloor decking, or floor framing cavity insulation shall and cantilevered floors) be permitted to be in contact with the op side of sheathing, or continuous insulation installed on the underside of floor framing and extends from the bottom to the top of all perimeter floor framing members. Crawl space walls Exposed earth in unvented crawl spaces shall be covered with a Where provided instead of floor insulation, insulation Class I vapor retarder with overlapping joints taped. shall be permanently attached to the crawispace walls. Shafts, penetrations Duct shafts, utility penetrations, and flue shafts opening to exterior or unconditioned s ace shall be sealed. . Batts in narrow cavities shall be cut to fit, or narrow Narrow cavities cavities shall be filled by insulation that on installation readily conforms to the available cavity spaces. Garage separation Air sealing shall be provided between the garage and conditioned spaces. r Recessed lighting Recessed light fixtures installed in the building thermal envelope shall Recessed light fixtures installed in the building be sealed to the drywall. thermal envelope shall be air tight and IC rated. Plumbing and wiring Batt insulation shall be cut neatly to fit around wiring and plumbing in exterior walls, or insulation that on installation readily conforms to available space shall extend behind Pioing and wiring, Shower/tub The air barrier installed at exterior walls adjacent to showers and Exterior walls adjacent to showers and tubs shall be on exterior wall tubs shall separate them from the showers and tubs. insulated. Electrical/phone box on The air barrier shall be installed behind electrical or communication exterior walls boxes or air -sealed boxes shall be installed. HVAC register boots HVAC register boots that penetrate building thermal envelope shall be sealed to the sub -floor or drywall. Concealed When required to be sealed, concealed fire sprinklers shall only be sealed sprinklers in a manner that is recommended by the manufacturer. Caulking or other adhesive sealants shall not be used to fill voids between fire sprinkler cover plates and Walls or ceilings. a. lie ILIvu, II IOrJGGUUII UI ivy wdus snap ue In accoruance wan me;prowsions or icu-4uu. ., 5/16/2018'3:22 PM EnergyGaugeO USA - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 1 of 1 4. FORM R405-2017 FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION Florida Department of Business and Professional Regulation - Residential Performance Method Project Name: PREVO GUEST HOUSE Builder Name: Street: 210 N BROCKSMITH ROAD Permit Office: ST LUCIE COUNTY City, State, Zip: FORT PIERCE, FL, Permit Number: Owner: Jurisdiction: ST LUCIE COUNTY Design Location: FL, Fort Pierce County:: St. Lucie (Florida Climate Zone 2 ) 1. New construction or existing New (From Plans) 9. Wall Types (1536.0 sqft.) Insulation Area 2. Single family or multiple family Single-family a. Frame - Wood, Exterior R=19.0 1536.00 f? 3. Number of units, if multiple family 1 b. N/A R= ft2 c. N/A R= f124. Number of Bedrooms 1 d. N/A R= ft' 5. Is this a worst case? No 10. Ceiling Types (960.0 sgft.) Insulation Area 6. Conditioned floor area above grade (W) 960 a. Roof Deck (Unvented) b. N/A R=20.0 960.00 f12 R= ff' Conditioned floor area below grade (f?) 0 c. N/A R= ft2 7. Windows(118.0 sgft.) Description Area 11. Ducts R f12 a. U-Factor: Sgl, U=0.65 70.00 ft2 SHGC: SHGC=0.25 b. U-Factor: SgI, U=0.70 48.00 ft2 12. Cooling systems kBtu/hr Efficiency SHGC: SHGC=0.30 a. Central Unit 10.9 SEER:19.00 c. U-Factor: N/A f12 b. Central Unit 9.0 SEER:19.00 SHGC: d. U-Factor: N/A ft2 13. Heating systems kBtu/hr Efficiency SHGC: I a. Electric Heat Pump 17.0 HSPF:9.00 b. Electric Heat Pump 17.0 HSPF:9.00 Area Weighted Average Overhang Depth: 1.500 ft. Area Weighted Average SHGC: 0.270 14. Hot water systems 8. Floor Types (960.0 sgft.) Insulation Area a. Electric Cap: 40 gallons a. Slab -On -Grade Edge Insulation R=0.0 960.00 ft' b. Conservation features EF: 0.980 b. N/A R= ft2 None c. N/A R= ft2 15. Credits None Glass/Floor Area: 0.123 Total Proposed Modified Loads: 28.29 PASS S Total Baseline Loads: 39.56 I hereby certify that the plans and specifications covered by Review of the plans and this calculation are in compliance with the Florida Energy specifications covered by this Code. calculation indicates compliance A. co.�,'%''� -��o� A+ with the Florida Energy Code. PREPD BY: Before e construction is completed DATE: this building will be inspected for compliance with Section 553.908 I hereby certify that this building, as designed, is in compliance Florida Statutes. 1� « with the Florida Energy Code. C0D WE OWNER/AGENT' BUILDING OFFICIAL: DATE: DATE: - Compliance requires certification by the air handler unit manufacturer that the air handler enclosure qualifies as certified factory -sealed in accordance with R403.3.2.1. - Compliance requires an Air Barrier and Insulation Inspection Checklist in accordance with R402.4.1.1 and this project requires an envelope leakage test report with envelope leakage no greater than 7.00 ACH50 (11402.4.1.2). 5/16/2018 3:22 PM EnergyGauge® USA - FlaRes2017 Section R405.4.1 Compliant Software Page 1 of 5 FORM R405-2017 PROJECT Title: PREVO GUEST HOUSE Bedrooms: 1 Address Type: Street Address Building Type: User Conditioned Area: 960 Lot # Owner Name: Total Stories: 1 Block/Subdivision: # of Units: 1 Worst Case: No PlatBook: Builder Name: Rotate Angle: 0 Street: 210 N BROCKSMITH R Permit Office: ST LUCIE COUNTY Cross Ventilation: No County: St. Lucie Jurisdiction: ST LUCIE COUNTY Whole House Fan: No City, State, Zip: FORT PIERCE, Family Type: Single-family FL. New/Existing: New (From Plans) Comment: CLIMATE / Design Temp Int Design Temp Heating Design Daily Temp V Design Location TMY Site 97.5 % 2.5 % Winter Summer Degree Days Moisture Range FL, Fort Pierce FL VERO BEACH_MUNI , 39 90 70 75 299 62 Low BL06KS Number Name Area Volume 1 .MINISPLIT 1 648 8876 2 MINISPLIT 2 312 3120 SPACES Number Name Area Volume Kitchen Occupants Bedrooms InfilID Finished Cooled Heated 1 KITCHEN 180 2520 Yes 0 1 Yes Yes Yes 2 UTILITY 49 490 No 0 1 Yes Yes Yes 3 GREAT ROOM 419 5866 No 0 1 Yes Yes Yes 4 TOILET 24 240 No I 0 1 Yes Yes Yes 5 CLST 18 180 No 0 1 No Yes Yes 6 BEDROOM 169 1690 No 0 1 1 Yes Yes Yes 7 BATH 101 1010 No 0 1 Yes Yes Yes FLOORS � # Floor Type Space Perimeter PerimeteriR-Value Area Joist R-Value Tile Wood Carpet 1 Slab -On -Grade Edge Insulation KITCHEN 27 ft 0 i 180 ft2 ___- 1 0 0 2 Slab -On -Grade Edge Insulation UTILITY 14 ft 0' 49 ft2 ___ 1 0 0 3 Slab -On -Grade Edge Insulation GREAT ROOM 37 ft 0 419 ft2 _--- 1 0 0 4 Slab -On -Grade Edge Insulation TOILET 6 ft 0 24 ft2 1 0 0 5 Slab -On -Grade Edge Insulation CLST 1 ft 0 18 ft2 ---- 1 0 0 6 Slab -On -Grade Edge Insulation BEDROOM 26 ft 0 169 ft2 ____ 1 0 0 7Slab-On-Grade Edge Insulation BATH 18 ft 0 101 ft2 ___- 1 0 0 5/16/2018 3:22 PM EnergyGaugeO USA - FlaRes2017 Section R405.4.1 Compliant Software Page 2 of 5 FORM R405-2017 ROOF / Roof Gable Roof Solar SA Emitt Emitt Deck Pitch V # Type Materials Area Area Color Absor. Tested Tested Insul. (deg) 1 Gable or Shed Composition shingles 1154 ft2 320 ftz Medium 0.6 No 0.9 No 20 33.7 AtTIC # Type Ventilation Vent Ratio (1 in) Area RBS IRCC 1 Full attic Unvented 0 960 ft2 N N CEILING # Ceiling Type Space R-Value Ins Type Area Framing Frac Truss Type 1 Under Attic (Unvented) KITCHEN 20 Blown 180 ft2 0.1 Wood 2 Under Attic (Unvented) UTILITY 20 Blown 49 ft2 0.1 Wood 3 Under Attic (Unvented) GREAT ROOM 20 Blown 419 ft2 0.1 Wood 4 Under Attic (Unvented) TOILET 20 Blown 24 ft2 0.1 Wood 5 Under Attic (Unvented) CLST 20 Blown 18 ft2 0.1 Wood 6 Under Attic (Unvented) BEDROOM 20 Blown 169 ft2 0.1 Wood 7 Under Attic (Unvented) BATH 20 Blown 101ft2 0.1 Wood WALLS Adjacent Space Cavity Width Height Sheathing Framing Solar Below 0 - 1 S Exterior Frame - Wood KITCHEN 19 15 0 14 0 210.0 ft2 0 0 0.6 0 _ 2 W Exterior Frame - Wood KITCHEN 19 12 0 14 0 168.0 ft2 0 0 0.6 0 3 N Exterior Frame- Wood UTILITY 19 7 0 10 0 70.0 ft2 0 0 0.6 0 _ 4 W Exterior Frame - Wood UTILITY 19 7 0 10 0 70.0 ft2 0 0 0.6 0 _ 5 N Exterior Frame - Wood GREAT ROO 19 20 0 14 0 280.0 ft2 0 0 0.6 0 6 S Exterior Frame - Wood GREAT ROO 19 12 0 14 0 168.0 ft2 0 0 0.6 0 _ 7 W Exterior Frame - Wood GREAT ROO 19 5 0 14 0 70.0 f12 0 0 0.6 0 _ 8 E Exterior Frame - Wood TOILET 19 6 0 10 0 60.0 ft2 0 0 0.6 0 9 E Exterior Frame - Wood BEDROOM 19 13 0 10 0 130.0 ft2 0 0 0.6 0 _ 10 S Exterior Frame - Wood BEDROOM 19 13 0 10 0 130.0 ft2 0 0 0.6 0 _ 11 N Exterior Frame - Wood BATH 19 13 0 10 0 130.0 ft2 0 0 0.6 0 _ 12 E Exterior Frame - Wood BATH 19 5 0 10 0 50.0 ft2 0 0 0.6 0 DOORS # Ornt Door Type Space Storms U-Value Width Height Area Ft In Ft In 1 W Insulated GREAT ROO None .39 3 8 24 ft2 6/16/2018 3:22 PM EnergyGaugeO USA - FlaRes2017 Section R405.4.1 Compliant Software Page 3 of 5 FORM R405-2017 WINDOWS Orientation shown is the entered, Proposed orientation. / Wall Overhang V/ # Ornt ID Frame Panes NFRC U-Factor SHGC Imp Area Depth Separation Int Shade Screening 1 S 1 Metal Low-E Single Yes 0.65 0.25 N 12.0 ft2 1 ft 6 in 1 ft 4 in None None 2 W 2 Metal Low-E Single Yes 0.65 0.25 N 18.0 ft2 1 ft 6 in 1 ft 4 in None None 3 S 6 Metal Low-E Single Yes 0.7 0.3 N 48.0 ft2 1 ft 6 in 1 ft 4 in None None 4 W 7 Metal Low-E Single Yes 0.65 0.25 N 18.0 ft2 1 ft 6 in 1 ft 4 In None None 5 S 10 Metal Low-E Single Yes 0.65 0.25 N 18.0 ft2 1 ft 6 in 1 ft 4 in None None 6 E 12 Metal Low-E Single Yes 0.65 0.25 N 4.0 ft2 1 ft 6 in 1 ft 4 in None None INFILTRATION # Scope Method SLA CFM 50 ELA EgLA ACH ACH 50 1 Wholehouse Proposed ACH(50) .000556 1399.5 76.83 144.49 .4057 7 HEATING SYSTEM # System Type Subtype Efficiency Capacity Block Ducts 1 Electric Heat Pump/ Split HSPF:9 17 kBtu/hr 1 Ductless 2 Electric Heat Pump/ Split HSPF:9 17 kBtu/hr 2 Ductless COOLING SYSTEM # System Type Subtype Efficiency Capacity Air Flow SHR Block Ducts 1 Central Unit/ Split SEER: 19 10.9 kBtu/hr 327 cfm 0.8 1 Ductless 2 Central Unit/ Split SEER: 19 9 kBtu/hr 270 cfm 0.8 2 Ductless HOT WATER SYSTEM # System Type SubType Location EF Cap Use SetPnt Conservation 1 Electric None UTILITY 0.98 40 gal 60.9 gal 120 deg None SOLAR HOT WATER SYSTEM FSEC Collector Storage Cert # Company Name System Model # Collector Model # Area Volume FEF None None ft2 5116/2018 3:22 PM EnergyGauge® USA - FlaRes2017 Section R405.4.1 Compliant Software Page 4 of 5 FORM R405 TEMPERATURES Programable Thermostat: N Ceiling Fans: Cooling Jan VentinJan Feb Feb Mar ?CMar Apr Apr May 1 May X Jun Jun Jul Jul Aug Aug Se Sep Oct OctX Nov Nov Dec Dec Jun [ Jul [ Aug Sep Thermostat Schedule: HERS 2006 Reference Hours Schedule Type 1 2 3 4 5 6 7 8 9 10 11 12 Cooling (WD) AM 78 78 78 78 78 78 78 78 80 80 80 80 PM 80 80 80 80 78 78 78 78 78 78 78 78 Cooling (WEH) AM PM 78 80 78 80 78 80 78 80 78 78 78 78 78 78 80 80 80 80 78 78 78 78 78 78 Heating (WD) AM PM 65 68 65 68 65 68 65 68 65 68 65 68 65 68 68 68 68 68 68 68 68 68 68 68 Heating (WEH) AM 65 65 65 65 65 65 65 68 68 68 68 68 PM 68 68 68 68 68 68 68 68 68 68 68 68 I 5/16/2018 3:22 PM EnergyGauge® USA - FlaRes2017 Section R405.4.1 Compliant Software Page 5of5