4 -+- wrightsoft° Project Summary MINISPLIT 1 QUICK CALCS, INC. 1 317 ST LUCIE LANE, FORT PIERCE, FL 34946 Phone: 772-466-6799 Fax 772466-6796 Email: QUICKCALCS aQAOL.COM I For: PREVO GUEST HOUSE 210 N BROCKSMITH ROAD, FORT PIERCE, FL Notes: I Design Information Weathelr: Fort Pierce, FL, US Job: Date: May 16, 2018 By: Winter Design Conditions Summer Design Conditions Outside db 42 OF Outside db 90 OF Inside db 70 °F Inside db 75 OF Design TD 28 'OF Design TD 15 OF Daily range M Relative humidity 50 % Moisture difference 61 gr/lb Heating Summary Sensible Cooling Equipment Load Sizing Structure 9167 Btuh Structure 6753 Btuh Ducts 1198 Btuh Ducts 1760 Btuh Central vent (0 cfm) 0 Btuh Central vent (0 cfm) 0 Btuh Humidification 0 Btuh . Blower 0 Btuh Piping 0 Btuh Equipment load 10365 Btuh Use manufacturer's data n Rate/swing multiplier 0.95 Infiltration Equipment sensible load 8087 Btuh Method Simplified Latent Cooling Equipment Load Sizing Construction quality I Average Fireplaces 0 Structure 1296 Btuh Ducts 457 Btuh Heating Cooling Central vent (0 cfm) 0 Btuh Area (ft2) 648 648 Equipment latent load 1753 Btuh Volume (ft3) 8876 8876 Air changes/hour 0.41 0.21 Equipment total load 9840 Btuh Equiv. AVF (cfm) 61 1 31 I Req. total capacity at 0.70 SHR 1.0 ton Heating Equipment Summary Cooling Equipment Summary Make DAIKIN AC Make DAIKIN AC Trade DAIKIN Trade DAIKIN Model RX12NMVJU Cond RX12NMVJU AHRI ref 8064266 Coil FTX12NMVJU AHRI ref 8064266 Efficiency 9 HSPF Efficiency 12.5 EER, 19 SEER Heating input Sensible cooling 7630 Btuh Heating output 8100 Btuh @ 47°F Latent cooling 3270 Btuh Temperature rise 18' OF Total cooling 10900 Btuh Actual air flow 400 cfm Actual air flow 400 cfm Air flow factor 0.039 i cfm/Btuh Air flow factor 0.047 cfm/Btuh Static pressure 0. in H2O Static pressure 0 in H2O Space thermostat Load sensible heat ratio 0.83 Capacity balance point = 45 OF Backup: Input = 3 kW, Output = 10083 Btuh, 100 AFUE Calculations approved byACCA to meet aI ;Tet enIF M ual 8t . y wrightsoft, i 2018-May-1615:21:27 �-- Right -Suite® Universal 2017 17.0.08 RSU08101 Page 1 '4CC�4' E:\Documnets\Wrightsoft HVAC\PREVO GUEST HOUSE.rup Calc - MJ8 Front Door faces: W ec ProIjt Summary Job: wrightaoft° Date: May 16, 2018 MINISPLIT 2 By: QUICK CALCS, INC. 317 ST LUCIE LANE, FORT PIERCE, FL 34946 Phone: 772-466-6799 Fax 772.466.6796 Email: QUICKCALCS ,AOL.COM Proje,ct Informiation I For. PREVO GUEST HOUSE 210 N BROCKSMITH ROAD, FORT PIERCE, FL Notes: i Design • • Weather: Fort Pierce, FL, US Winter Design Conditions Summer Design Conditions Outside db 42 OF Outside db 90 OF Inside db 70 OF Inside db 75 OF Design TD 28 °F Design TD 15 OF Daily range M Relative humidity 50 % Moisture difference 61 gr/lb Heating Summary Sensible Cooling Equipment Load Sizing Structure 4392 Btuh Structure 4916 Btuh Ducts 710 Btuh Ducts 1098 Btuh Central vent (0 cfm) 0 Btuh Central vent (0 cfm) 0 Btuh Humidification 0 Btuh Blower 0 Btuh Piping 0 Btuh Equipment load 5103 Btuh Use manufacturer's data n Rate/swing multiplier 0.95 Infiltration Equipment sensible load 5713 Btuh Method Simplified Latent Cooling Equipment Load Sizing Construction quality Average Fireplaces 0 Structure 625 Btuh Ducts 290 Btuh Area (ft2) Heatingg Coolingg 312 ' 312 Central vent (0 cfm) Equipment latent load 0 916 Btuh Btuh Volume (W) 3120 3120 Air changes/hour 0.56 0.29 Equipment total load 6629 Btuh Equiv. AVF (cfm) 29 15 Req. total capacity at 0.70 SHR 0.7 ton Heating Equipment Summary) Cooling Equipment Summary Make DAIKIN AC Make DAIKIN AC Trade DAIKIN Trade DAIKIN Model RX09NMVJU Cond RX09NMVJU AHRI ref 8064265 Coil FTX09NMVJU AHRI ref 8064265 Efficiency 9 HSPF Efficiency 12.5 EER, 19 SEER Heating input I Sensible cooling 6300 Btuh Heating output 10000 Btuh @ 470F Latent cooling 2700 Btuh Temperature rise 30 OF Total cooling 9000 Btuh Actual air flow 300 cfm Actual air flow 300 cfm Air flow factor 0.059 cfm/Btuh Air flow factor 0.050 cfm/Btuh Static pressure 0 in H2O Static pressure 0 in H2O Space thermostat Load sensible heat ratio 0.87 Capacity balance point = 27 OF Backup: Input = 1 kW, Output = 4698 Btuh, 100 AFUE Calculations approved byACCA to meet all requirements of Manual J 8th Ed. c - - wrightsoft- 2018-May-1616:21:27 g. Rlght-Sulte® Universal 2017 17408 RSU08101 Page 2 '4CCA E:1DocumnetslWrightsoft HVACIPREVO GUEST HOUSE.rup Calc = M.18 Front Door faces: W wrightsoft' Right-M Worksheet MINISPLIT 1, QUICK CALCS, INC. 317 ST LUCIE LANE, FORT PIERCE, FL 34946 Phone: 772-466-6799 Fax 772-466-6796 Email: QUICKCALCS@AOL.COM Job: Date: May 16, 2018 By: 1 Room name MINISPLKT 1 KITCHEN 2 3 Exposed wall Room height 78.0 ft 13.7 ft 27.0 ft 14.0 ft heat/cool 4 5 Room dimensions Room area 648.0 ft' 12.0 x 15.0 ft 180.0 ft' Ty Construction U-value Or HTM Area (ft') Load Area (ft2) Load number (Btuh/ft'L°F) (Btuh/ft') or perimeter (ft) (Btuh) or perimeter (ft) (Btuh) Heat Cool Gross N/P/S Heat Cool Gross N/P/S Heat Cool 6 : W Val t—G 12E-0sw 12E-0sw 2 glazing, clr low-e 0.068 0.068 0.650 n a a 1.90 0.00 0.00 1.118 0.00 0.00 350 0 0 350 0 0 666 0 0 414 0 0 0 0 0 0 0 0 0 0 0 0 0 0 11 12E-Osw 2 glazing, clr low-e 0.068 0.650 s s 1.96 18.20 1.18 14.99 378 12 318 12 605 218 376 180 210 12 198 12 377 218 234 180 2 glazing, cir low-e 2 glazing, clr low-e 12E-0sw 0.650 0,650 0.068 s s w 0.06 18.20 1.90 0.00 14,99 1.18 0 48 308 0 48 248 0 874 472 0 720 293 0 0 168 0 0 150 0 0 286 0 0 177 2 glazing, clr low-e 11DO 0.650 0.390 w w 18.26 10.92 33.77 10.34 36 24 0 24 655 262 1216 248 18 0 0 0 328 0 608 0 C 16A-Wad 0.032 - 0.90 2.24 648 648 581 1452 180 180 161 403 F 22Atvh 1.358 - 38.02 0.00 I I I i 648 78 2966 0 180 27 1027 0 6 c)AEID excursion 343 233 Envelope loss/gain 7300 5241 2397 1836 12 a) Infiltration 1867 611 681 187 b) Room ventilation 0 0 0 0 13 Internal gains: Occupants @ 230 0 0 0 0 Appllances/other 1000 1000 Subtotal (lines 6 to 13) 9167 6753 3078 3022 Less external load 0 0 0 0 14 Less transfer Redistribution Subtotal 0 0 9167 0 0 6763 0 0 3078 0 0 3022 15 Duct loads 13% 26% 1198 1760 130/0 26% 402 788 Total room load Air required (cfm) 1 10365 1400 8512 400 1 1 3480 134 3810 179 Calculations approved bvACCA to meet all requirements of Manual J 8th Ed. A&k -pp- wriyhtsoft" Right-Sulte® Universal 2017 17.0.08 RSU08101 2018•May-May1 Page 1 EADocumnetslWrightsoft HVACIPREVO GUEST HOUSE.rup , Cafe = MJ8 Front Door faces: W 9 -�- wrightsoft° Right-M Worksheet Job: MINISPLIT 11 Date: May 16, 2018 QUICK CALCS, INC. y 317 ST LUCIE LANE, FORT PIERCE, FL 34946 Phone: 772466-6799 Fax 772466-6796 Email: QUICKCALCS@AOL.COM 1 Room name UTILITY GREAT ROOM 2 Exposed wall 14.0 ft 37.0 ft 3 Room height 10.0 ft heat/cool 14.0 ft heat/cool 4 5 Room dimensions Room area 7.0 x 7.0 ft 49.0 ft2 1.0 x 419.0 ft 419.0 ft2 Ty Construction U-value Or HTM Area (ft') Load Area (ft2) Load number (Btuh/f?-°F) (Btuh/ft2) or perimeter (ft) (Btuh) or perimeter (ft) (Btuh) Heat Cool Gross N/P/S Heat Cool Gross WP/S Heat Cool 6 W 1�/ 1---G 12E-Osw 12E-Osw 2 glazing, clr low-e 0.068 0.068 0.650 n a a 1.90 0.00 0.00 1.18 0.00 0.00 70 0 0 70 0 0 133 0 0 83 0 0 280 0 0 280 0 0 633 0 0 331 0 0 VVVVV�����JJJJJ G 11 12E-Osw 2 glazing, clr low-e 0.068 0.650 s s 1.90 18.20 1.18 14.99 0 0 0 0 0 0 0 0 168 0 120 0 228 0 142 0 2 glazing, clr low-e 2 glazing, clr low-e 12E-Osw 0.650 0.650 0.068 s s w 0.00 18.20 1.90 0.00 14.99 1.18 0 0 70 0 0 70 0 0 133 0 0 83 0 48 70 0 48 28 0 874 53 0 720 33 Vl/ IL_.Cp 2 glazing, clr low-e 11D0 0.650 0.390 w w 18.20 10.92 33.77 10.34 0 0 0 0 0 0 0 0 18 24 0 24 328 262 608 248 C F 16A-30ad 22Artph 0.032 1.358 - - 0.90 38.02 i I I . i I I I 1 I I Z24 0.00 49 49 49 14 44 532 110 0 419 419 419 37 375 1407 939 0 6 c)AED excursion 0 109 Envelope loss/gain 843 275 4061 3130 12 a) Infiltration 252 69 934 256 b) Room ventilation 0 0 0 0 13 Internal gains: Occupants @ 230 0 0 0 0 Appllances/other 0 0 Subtotal (lines 6 to 13) 1095 345 4994 3386 Less wdemal load 0 0 0 0 14 Less transfer Redistribution Subtotal 0 0 1095 0 0 345 0 0 4994 0 0 3386 15 Duct loads 130/0 26% 143 90 130/0 26% 652 882 Total room load Air required (cfm) 1238 48 434 20 5647 218 4268 201 Calculations approved WACCA to meet all requirements of Manual J 8th Ed. AAA � wrightsoft' Right -Suite® Universal 2017 17.0.08 RSU08101 2018-May-16 1 Page 2 E:\Documnets\Wrightsoft HVAC\PREVO GUEST HOUSE.rupl Cale = MJ8 Front Door faces: W 9 - - wrightsofts Flight-M Worksheet Job: MINISPLIT 2' Date: May 16, 2018 QUICK CAL.CS, INC. By. 317 ST LUCIE LANE, FORT PIERCE, FL 34946 Phone: 772-466.6799 Fax 772-466.6796 Em311: QUICKCALCS@,AOL,COM 1 Room name MINISPLIT 2 TOILET 2 3 Exposed wall Room height 50.0 ft 10.0 ft 6.0 ft 10.0 ft heaticool 4 5 Room dimensions Room area 312.0 f12 6.0 x 4.0 ft 24.0 ft2 Ty Construction U-value Or H7M Area (fe) Load Area (ft') Load number (Btuh/ft2 °F) (Btuh/ftz) or perimeter (ft) (Btuh) or perimeter (ft) (Btuh) Heat Cool Gross Ni Heat Cool Gross N/P/S Heat Cool 6 W V}/ �-G 12E-0sw 12E-0sw 2 glazing, clr low-e 0.068 0.068 0.650 n a a 1.90 1.90 18.20 1.18 1.18 33.77 130 240 4 130 236 0 248 449 73 154 279 135 0 60 0 0 60 0 0 114 0 0 71 0 11 12E-0sw 2 glazing, clr low-e 0.068 0.650 s s 1.90 0.00 - 1.18 0.00 130 0 112 0 213 0 133 0 0 0 0 0 0 0 0 0 2 glazing, clr low-e 2 glazing, clr low-e 12E-0sw 0.650 0.650 0.068 s s w 18.20 0.00 0.00 14.99 0.00 0.00 18 0 0 18 0 0 328 0 0 270 0 0 0 0 0 0 0 0 0 0 0 0 0 0 V�/ 2 glazing, clr low-e 11D0 0.650 0.390 w w 0.00 0.00 0.00 0.00 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 LG DD C 16A-30ad 0.032 - 0.90 2.24 312 312 280 699 24 24 22 54 F 22A-tph 1.358 - 38.02 i I i i i i 0.00 312 50 1901 0 24 6 228 0 6 c)AED excursion 0 -1 Errmlope loss/gain 3491 1669 364 124 12 a) Infiltration 901 247 108 30 b) Room ventilation 0 0 0 0 13 Internal gains: Occupants @ 230 0 0 0 0 Appliances/other 3000 750 Subtotal (lines 6 to 13) 4392 4916 472 903 Less odemal load 0 0 0 0 14 Less transfer Redistribution Subtotal 0 0 4392 0 0 4916 0 2 474 0 4 907 15 Duct loads 160/6 22% 710 1098 16% 221/6 77 203 Total room load Air required (cfm) 5103 300 6014 300 550 32 1110 55 Calculations approved WACCA to meet all requirements of Manual J 8th Ed. c 4j4- wrightsoft- RI ht S 2018-May-1615:21:27 Ite®U I 12017 g - u n versa I7.0.08 RSU08101 Page 3 E:\Documnets\Wdghtsoft HVAC\PREVO GUEST HOUSE.rup Calc = MJ8 Front Door faces: W - wrightsoft• Right-JO Worksheet Job: MINISPLIT 2 Date: May 16, 2018 By: QUICK CALCS', INC. 317 ST LUCIE LANE, FORT PIERCE, FL 34946 Phone: 772-466-6799 Fax 772.466.6796 Email: QUICKCALCS@AOL.COM 1 Room name CLST BEDROOM 2 Exposed wall 0 ft 26.0 ft 3 Room height 10.0 ft heat/cool 10.0 ft heat/cool 4 5 Room dimensions Room area 2.0 x 9.0 ft 18.0 ft' 13.0 x 13.0 ft 169.0 fN Ty Construction U-value Or HTM Area (ft2) Load Area number (Btuh/ftkoF) (Btuh/ft') or perimeter (ft) (Btuh) or perimeter (ft) (Bttuh) Heat Cool Gross NIP/S Heat Cool Gross N/P/S Heat Cool 6 W Val �--G 12E-0sw 12E-0sw 2 glazing, clr low-e 0.068 0.068 0.650 n a a 1.90 1.90 18.20 1.18 1.18 33.77 0 0 0 0 0 0 0 0 0 0 0 0 0 130 0 0 130 0 0 248 0 0 154 0 V,V 11 12E-0sw 2 glazing, clr low-e 0.50 0.6650 s s 1.0 0.000 . 0 0.0000 0 0 0 0 0 0 0 0 130 0 11 0 0 213 0 133 0 2 glazing, cir low-e 2 glazing, clr low-e 12E-0sw 0.650 0.650 0.068 s s w 18.20 0.00 0.00 14.99 0.00 0.00 0 0 0 0 0 0 0 0 0 0 0 0 18 0 0 18 0 0 328 0 0 270 0 0 W 2 glazing, cir low-e 11D0 0.650 0.390 w w 0.00 0.00 0.00 0.00 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 LI--_G C 16A-00ad 0.032 - 0.90 2.24 18 18 16 40 169 169 151 379 F 22A-tph 1.358 - 38.02 I i I I i 1 I 0.00 18 0 0 0 169 26 989 0 6 c)AED excursion 0 -3 Envelope loss/gain 16 40 1928 932 12 a) Infiltration 0 0 469 128 b) Room ventilation 0 0 0 0 13 Internal gains: Occupants @ 2301 0 0 0 0 Appliances/other 0 1500 Subtotal (lines 6 to 13) 16 40 2397 2560 Less external load 0 0 0 0 14 Less transfer Redistribution Subtotal 0 -16 0 0 -40 0 0 7 2404 0 18 2578 15 Duct loads 16% 22% 0 0 160/0 22°/u 389 576 Total room load Air required (cfm) 0 0 0 0 2793 164 3154 157 Calculations approved bIACCA to meet all requirements of Manual J 8th Ed. wrightsoft- 2018-May-16 15:21:27 .�A Right -Suite® Universal 20' 1 17.0.08 RSU08101 Page 4 EADocumnetslWrightsoft WACIPREVO GUEST HOUSE.rup Cal. = MJ8 Front Door faces: W - wrightsoft® Right-JO Worksheet Job: MINISPLIT 2 Date: May 16, 2018 QUICK CALCS; INC. By: 317 ST LUCIE LANE, FORT PIERCE, FL 34946 Phone: 772-466.6799 Fax 772466-6796 Email: QUICKCALCS@AOL.COM 1 Room name BATH 2 Exposed wall 18.0 ft 3 Room height 10.0 ft heat/cool 4 5 Room dimensions Room area 1.0 x 101.0 ft 101.0 ft' Ty Construction U-value Or �H7M Area (ft") Load Area - Load number (Btuh/ftMF) (Btuh/ft2) or perimeter (ft) (Btuh) or perimeter Heat Cool Gross N/P/S Heat Cool Gross N/P/S Heat Cool 6 W W L—G 12E-0sw 12E-0sw 2 glazing, clr low-e 0.068 0.068 0.650 n a a 1.90 1.90 18.20 1.18 1.18 33.77 130 50 4 130 46 0 248 88 73 154 64 135 11 2 glaz(ng, clr low-e 2 glazing, 0.650 0.650 s s 1.90 0.00 1.00 0.00 0 0 0 0 0 0 0 0 2 glazing, cir low-e 2 glazing, clr low-e 12E-Qsw 0.650 0.650 0.068 s s w 18.20 0.00 0.00 14.99 0.00 0.00 0 0 0 0 0 0 0 0 0 0 0 0 V�J E�--(D 2 glazing, clr low-e 11DO 16A-30ad 0.650 0.390 0.032 w w - 0.00 0.00 0.90 0.00 0.00 2.24 0 0 101 0 0 101 0 0 90 0 0 226 C F 22A-tph 1.358 - 38.02 I I I I I i I I I 1 1 I 0.00 101 18 684 0 6 c)AED w cursion 4 Envelope loss/gain 1183 574 12 a) Infiltration 324 89 b) Room ventilation 0 0 13 Internal gains: Occupants @ 230, 0 0 Appliances/other 750 Subtotal (lines 6 to 13) 1507 1412 Less external load 0 0 Less transfer 0 0 Redistribution 7 18 14 Subtotal 1515 1431 15 Duct loads 160/0 22% 245 320 Total room load 1759 1750 T Air required (cfm) 103 87 I c -�- wrilghtsoft- Right-Sulte® Universal 2017 17.0.08 RSU06101 2018-May-16 15:21:27 . C a EADocumnets\Wrightsoft HVAC\PREVO GUEST HOUSE.mp Cale = MJ8 Front Door faces: W Page 5