Loading...
HomeMy WebLinkAboutGUESS HOUSE PLANSH 112 24 5'-6" / �'P logo PKT DRo , I � / / I c o � I, // BATH `o o r # G I N 2(011 SD # 2880 2880 HC DR } HC OR I � w 'I I� RIDGE `VAUL" i� # I� I II I GREATIROOM �I I I 6-0" I WKJv TILIT' or -' a \ I SH 2 ?080 SH : 'RQLS DRI THRSHL I 8'-7" 3'-5" T-5" PORCH ------------------- 6-0" 12'-0" 24'-0" FLOOR & ELECTRICAL 1/4 =1-0 SIP 2" VTR 2 �A2.00� PLAN SANITARY RISER DIAGRAM I I I -2 112" VTR I I 2 FOUNDATION PLAN 1 /4" = 1'-0" I PRODUCT OPENING PRODUCT MANUFACTURER MODEL# APPROVAE# GLASS ATTACHMENTMETHOD DESIGN DESIGN TYPE PRESSURES PRESSURES (WORST CASE) MNDOWS ZONE 4-33,89 `60 RLVERLINE V1 SEI#IFS/70 F1,#i.. IMPACE #10 PANHEADS@ 6" MAX. O.G., 3" MAX, ON CORNERS,. ZONE 5:41.1.:4 . RUILDING SERIES 21,27 14911..5. 1.5"MRN. ENIIIEDNEFNT AND .75" DISTANCE TO EDG£.. PRODUCTS CORP. DOOR. ZONE 4-33..88 -70 MASONITE OPAQUE DOUBLE F4N'. IMPACT #10 WOOD SCREWS @ 5" MAX, O,C., G" ON CORNERS, ZONE S -42,14 INTERNATIONAL. DOOR 22513.5. 1•1/2." N1IM EMBEDMENT, %" DISTANCE TO EDGE" 6- &3" CLUSTERS DOOR ZONE 4'-33.94 -65 ANDERSON CORP. E�SERIES rjUDING FW IMPACT #14: WOOD SCREWS w 12J MAX, Oa C,, 6- ON CORNERS, ZONE S-4I,14 9,STATIONARY 2147E Ir AT SI U, TO ACHIEVE 2.I/r PAIN, EiUIEDNIENT AND PATIO DOOR DISTANCE TO EDGE k0of ZONE 1. - 2904 N/A GAF ROOFING ASPHALT SHINGLES FW i4/A. 14) NAILS PER SHINGLE ._.... ZONE 2.- 48,40 10124A ZONE 3- 72.,60 ME `,LA( LIFRF N I'' PftCIVIC>€DON 1 TO NDICA I E OL,F RE`.+IFA, ARC APPROVAL FOP, USE OF PPCDUI IS 3 s5T`� I�OR THS STRUICTURL, rME ACCEPTANCE OFTPI[5@ PR0DUCT5 ^.UG NIETFAQD@ OF ATT+a,.? M, , IT ARF ?AS,',C .'`: MRfl Y UPON TEuT DATA FhT' t]'..I?,." T,.G +alltlli,:fht"7•tPER "V. 4,tiN CQfi?i ! J IT ixb?•I"d E?JCx;NFGii S C,RI I I1 CA n OISANLt UVIPUlI-NOLVA'3'RAN A Y OR COARARTF ^4YTHIS . 0FRCF FOR7H.TF N1,00 01, TRUSS 0 OtAIRING POI TfSS TRUSS ACTUAL UPLIFT (GROUPEDO WORST CASE99 SIMPSON CONINEC€q(S) CO.NNECT09,1) mFL}FgQESWN E' A-S EA EACH 6081# (1) MTS 16 1000# 14-1 X14/2' SGEA1. 4r O,C; 2034 (1) MTS 16 1000 14-1 �1a1 j2" SGEEI EACH I 10 (1) WITS 16 100 14-1 1L1-1/r TRUSS INFORMATION A Ll`S, I-RONd MAN UFACT LIRE W5 t HCX0 {`siiAV;jNGS. SOUTHERN TRUSS, JOB aia6-5594I`1A ED � 2-2111 1' AI... (.A05 R F P R F SFNT W,,". RST CAf L0AI 4EJG FOIR v5RD, PF D CAI FGORI -Sz FF'MAN UFAL I GIRER`7 ABUSE 1.AYOU I FOR FRO/ 55 ID AND 5TRAPRPAG PT_r>r1 EMIT TABLE R301.20) CLIMATIC AND GEOGRAPHIC DESIGN CRITERIA GROUND SNOW LOAD WIND DESIGN SEISMIC DESIGN CATEGORY! 3UBJECTTO DAMAGE FROM WINTER DESIGN TEMPO ICE BARRIER UNDERLAYMENT REQUIREDh FLOOD HAZARDS9 AIR FREEZING INDEX MEAN ANNUAL TEMPI Speedo (mph) Topographic effectsk Westheringa Frost line depthb Termite° NA See Fig. r301.2(4) NA Negligible I NA Very Heavy NA NA NA CERTIFICATION FOR DESIGN LOAD COMPLIANCE 1. DESIGN CODE: FLORIDA RESIDENTIAL CODE 2017 EDITION USING ASCE 7-10 2. STRUCTURAL DESIGN: ENCLOSED 3. RISK CATEGORY: 11 EXPOSURE CATEGORY: C 4. DESIGN WIND VELOCITY: 160 MPH 6. MEAN ROOF HEIGHT: 12'-8" ROOF PITCH: 8:12 6. COMPONENTS & CLADDING DESIGN PRESSURE: PSF, BASED ON ACTUAL SQ. FT. @ 30' MRH (WORST CASE) ZONE 1: -26.62 ZONE 2: -32.67 ZONE 3: -36.3 ZONE 4: -33.88 ZONE 5: -41.14 GARAGE: NIA 7. DESIGN LOADS: FLOOR 75 PSF ROOF/ DEAD: 15 PSF ROOF/ LIVE: 30 PSF 8. WERE SHEAR WALLS CONSIDERED FOR STRUCTURE? YES 9. IS A CONTINUOUS LOAD PATH PROVIDED? YES 10. DESIGN SOIL BEARING PRESSURE: 2000 PSF DRYWALL NOTES DRYWALL SHALL CONFORM WITH SECTION R702.3.1 OF THE FLORIDA BUILDING r-ODE (RESIDENTIAL). CERAMIC TILE IN TUB/ SHOWER COMPARTMENTS SHALL CONFORM WITH SECTION R702.4 OF THE FLORIDA BUILDING CODE (RESIDENTIAL). WALL AND CEILING FINISHES SHALL HAVE A FLAME SPREAD CLASSIFICATION OF NOT GREATER THAN 200 AND A SMOKE -DEVELOPED INDEX OF NOT GREATER THAN 450. ATTIC INSULATION SHALL HAVE A CRITICAL RADIANT FLUX NOT LESS THAN 0.12 WATT PER SQUARE CENTIMETER WITH A FLAME SPREAD NOT EXCEEDING 25 WITH AN ACCOMPANYING SMOKE -DEVELOPED INDEX NOT EXCEEDING 450. FOAM BLOCK INSULATION SHALL HAVE A FLAME SPREAD OF NOT MORE THAN 75 AND SMOKE -DEVELOPED INDEX OF NOT MORE THAN 450. STRUCTURAL NOTES 1. STRUCTURAL LUMBER TO BE HEM -FIR #2 GRADE OR BETTER W/ 1000 PSI MIN. FIBER STRESS VALUE 2. CONCRETE SLABS AND FOOTINGS TO BE 2500 PSI MIN 3. REINFORCING STEEL SHALL BE GRADE 60 OR BETTER W/ 30" MIN. LAP 4. CONCRETE COVER OVER REINFORCING STEEL: A. FOOTINGS: 3" B. BEAMS: 11/2" C. COLUMNS: 11/2" 5. FILL (SOIL) SHALL BE PLACED IN LIFTS NOT TO EXCEED 12" AND COMPACTED TO A MINIMUM OF 95% MODIFIED PROCTOR DENSITY 6. ALL COMPONENTS OF THIS STRUCTURE HAVE BEEN DESIGNED AND SELECTED TO WITHSTAND FORCES PER THE FLORIDA BUILDING CODE 2017 EDITION 7. DOOR & WINDOW ASSEMBLY COMPNENTS TO BE CERTIFIED BY MANUFACTURER FOR WIND FORCES PER THE FLORIDA BUILDING CODE 2017 EDITION PER WIND LOAD COMPLIANCE DESIGN PRESSURES 8. PRECAST/ PRESTRESSED CONCRETE LINTELS TO HAVE 6" MINIMUM BEARING. REFER TO LINTEL SCHEDULE FOR ADDITIONAL INFORMATION. 8. FOR METHOD OF ATTACHMENT OF DOORS & WINDOWS, REFER TO ATTACHED PRODUCT REVIEW AFFIDAVIT NOTE: ALL SIMPSON STRONT-TIE PRODUCTS IN CONTACT WITH TREATED LUMBER SHALL HAVE A MINIMUM Z-MAX COATING OR BETTER o(aANPIL BY G+ I I trio i°(ju fl4v ST, LUCIE COUNTY BUI REVIEWED FOR COMPL -W ARCHITECT Architectonic Inc 806 DELAWARE AVENUE FORT PIERCE, FLORIDA 34950 T: 772 460 7751 F: 772 460 4244 W W W.ARCHITECTONICINC.COM STATE REG # AA26003348 COPYRIGHT 2017 PROJECT GUEST HOUSE ST. LUCIE COUNTY. FL CLIENT PREVO DIVISION! CONSULTANTS PLANS ,(N`D PERWMUST BE KEPT 0 SITE OR NO INS ECTION(S) WILL BE FILE CO ELECTRICAL LEGEND "EP" SINGLE POLE SWITCH O 120/240V1 PH, DUPLEX CONVENIENCE OUTLET 200A MAIN BR. DUPLEX OUTLET W/ GROUND FAULT PROTECTION MOTOR OUTLET E UNDERGROUND ELECT. SERVICE: TKv WALL MOUNT LIGHT FIXTURE 3# 3/0 THWN CU. IN 2" CONDUIT 0- CEILING MOUNT LIGHT FIXTURE � CABLE TELEVISION OUTLET E #4 CU. GROUND TIED TO BLDG. STEEL, CWB & DRIVEN GROUND ROD SD SMOKE DETECTOR/ CARBON MONOXIDE ❑ J.B. FOR FAN/ LIGHT COMBO NOTE: ALL ELECTRICAL TO BE TIED TO EXISTING SERVICE AND PROVIDE ARCH FAULT& TAMPER PROOF RECEPTACLES ELECTRICAL RISER DIAGRAM THROUGHOUT COPPER SERVICE DOOR & WINDOW BUCK FASTENING DOOR AND WINDOW BUCKS SHALL BE ATTACHED WITH CASE HARD NAILS @ 12" O.C., WITH THE DOORS AND WINDOWS FASTENED W/ TAPCONS PER THE PRODUCT REVIEW AFFIDAVIT WITH A MINIMUM OF 1 114" EMBEDMENT INTO CONCRETE (THROUGH RAME). BUCK SHALL EXTEND BEYOND THE INTERIOR FACE OF THE FRAME PER 2017 FLORIDA BUILDING CODE W/ AMENDMENTS. I REGISTRATION MICHAEL J. SEAL, AIA AR96898 REVISIONS NO. DATE KEY PLAN SHEET TITLE / SHEET NUMBER PLANS & NOTES A1.00 PROJECT NUMBER R17122 DATE 04/10/2018 TOP 10' -0"9F BEAM TOP OF SLAB 0" 1 REAR ELEVATIO 1 /4 - 1 -011 _T10'OP-0" OF BEAN v TOP_OFSLAB v 0" FRONT ELEVATIO IL 1/4" = 1'-0" (-h TOP OF BEAM 10'-0-0" ml N TOP OF SLAB 0" ———--—————————— — — — — —— — — — LEFT SIDE ELEVATION 1/4" = 1'-0" TOP OF BEAM 10'-0" 0 weTOP OF SLAB 0" RIGHT SIDE ELEVATION `t % 1 /4" = l'-0" r \ MAXIMUM HEADER SPAN T-0" 6'-0" 9'-0" 12'-0" 16-0" 18'-0" WALL HEIGHT ISTUD SPACING 1 1 1 1 1 2 1 2 2 2 1 # OF HEADER STUDS SUPPORTING END OF HEADER 10'-0" OR LESS 16" O.C. 1 2 1 2 1 3 1 3 3 3 1 # OF FULL HEIGHT STUD @ EACH END OF HEADER 10"-0" OR MORE 16" O.C. 1 2 1 2 1 3 1 3 4 4 ROOF TRUSSES I I I I 1 l i-� POINT BEARIN 8 -- J J 1/2" - 1'-0" DOUBLE TOP PLATE CRIPPLE STUDS (NOT REQUIRED FOR 8'-0" HIGH WALL) HEADER (DOUBLE 2"X12" W/ 1/2" PLYWOOD SPACER, GLUED AND NAILED W/ 16d NAILS @ 8" O.C. STAGGERED BOTH SIDES) iTRAP EACH STUD AS REQUIRED W/ iMPSON LSTA 18 OR MTS 18 W/ (14) 10d JAILS 1EADER STUDS ULL HEIGHT STUDS DOTE: SIMPSON 18" FLAT STRAP MAY ZEPLACE MTS 16 OR EQUAL AT HEADER )NLY iTRAP EACH STUD AS REQUIRED W/ iMPSON SP4 OR SP6 W/ (6) 10d NAILS FIBERGLASS SHINGLES ON 30# FELT OVER 518" CDX PLYWOOD SHEATHING NAILED PER ROOF SHEATHING NAILING ZONE DETAIL PRE-ENGINEERED TRUSSES @ 24" O.C. SPRAY INSULATION _ SIMPSON MTS 16 W/ (14) 10d NAILS PER STRAPPING SCHEDULE DBL 2"X6" TOP PLATE 2"x4" SUB -FASCIA DRIP EDGE Vx6" FASCIA HARDIE SOFFIT HARDI PLANK LAP SIDING ON HOUSEWRAP OVER 1/2" CDX PLYWOOD W/ 8d NAILS @ 4" O.C. PERIMETER & 8" O.C. FIELD 2"X6" STUDS @ 16" O.C. NOTE: PROVIDE SIMPSON SP6 @ TOP AND BOTTOM PLATES EVERY OTHER STUD W/ (6) 10d NAILS R-19 SPRAY INSULATION 2"X6" BOTTOM PLATE W/ 1/2" DIA. A.B. @ 24" O.C. W/ 2"x2"xl/8" WASHERS REFER TO FOUNDATION PLAN FOR SIZES AND P.T. BOTTOM PLATE G HEADER CONNECTION DETAIL NOTE: FOR ADDITIONAL INFORMAITON REFER TO TYPICAL WALL SECTION 5 GABLE END DETAIL1 2"x4" LATERAL BRACING - FIRST 1/2" GYP. BOARD CEILING 1/2" GYP. BOARD WOOD BASE C'- III— °- - •. :. -- •' I —III) 11 II - III I - FOUR TRUSSES TYPICAL WALL SECTION (FRAME) RIDGE & V-0" E .07 _ SIDE OF RIDGE 3/4" = 1'-0" TOP & BOTTOM CHORD 2"x4" "X" BRACING FIRST FOUR TRUSSES @ RIDGE & 6-0" O.C. EA. SIDE SIMPSON MTS 16 W/ (14) OF RIDGE 10d NAILS PER STRAPPING SCHEDULE LAP SIDING ON HOUSEWRAP OVER DBL 2"X6" TOP PLATE- 5/8" CDX PLYWOOD SHEATHING W/ 8d 2"x4" SUB -FASCIA NAILS @ 4" O.C. PER. & 6" O.C. FIELD 2"x4" CONTINUOUS NAILER DBL 2"x6" TOP PLATE SIMPSON MTS16 W/ (14) 10d NAILS @ 32" O.C. P-2 P_3 P-1 RIDGE P-2 P-1 P-2 P-2 RIDGE C� P-3 P-1 �\P-2 N N JP p-1 a a P-1 P-2 P-3 GABLE P-3 ROOF SHEATHING NAILING ZONE INFORMATION P-3 P-3 ZONE 1: REMAINING AREA W/ 8d RING SHANK @ 6" O.C. PERIMETER & 6" O.C. FIELD ZONE 2: 4' LENTH W/ 8d RING SHANK @ 4" O.C. PERIMETER & 6" O.C. FIELD ZONE 3: 5'X5' @ HIP AND 5' LENGTH @ GABLE ENDS W/ 8d RING SHANK @ 4" O.C. PERIMETER & 4" O.C. FIELD NOTES 19/32" CDX PLYWOOD SHEATHING 25'-0" OR GREATER MEAN ROOF HEIGHT SHALL HAVE 10d RINGSHANK NAILS UNDERLAYMENT FELT SHALL BE 30# FELT COMPLYING W/ ASTM D226 ASPHALT SHINGLES SHALL COMPLY WITH ASTM D3161 CLASS F, ASTM D7158 CLASS H OR TAS.107 AND SHALL HAVE FACTORY APPLIED SELF SEAL STRIPS OR BE INTERLOCKING 1 "4" T&G CEDAR CEILING HARDIE SOFFIT SIMPSON AC6 POST CAP & (2) LSTA 18 FLAT STRAPS NAILED PER MANUFACTURERS REQ'MTS.- P.T. 6"x6" POST SIMPSON POST BASE ABU66 W/ (12) 10d NAILS & 5/8"DIA A.B. REFER TO FOUNDATION PLAN FOR SIZES AND REINFORCING- TYPICAL WOOD POST COLUMN DETAIL 3/4" = V-0" ARCHITECT Architectonic Inc 806 DELAWARE AVENUE FORT PIERCE, FLORIDA 34950 T: 772 460 7751 F: 772 460 4244 W W W.ARCHITECTONICINC.COM STATE REG # AA26003348 COPYRIGHT 2017 PROJECT GUEST HOUSE ST. LUCIE COUNTY, FL CLIENT PREVO CONSULTANTS REGISTRATION OF FLO/�� � • oy E� AL 9 TEREO MICHAEL J. SEAL, AIA AR96898 REVISIONS NO. DATE REVISION KEY PLAN SHEET TITLE / SHEET NUMBER ELEVATIONS & DETAILS A2.00 PROJECT NUMBER R17122 DATE 04/10/2018