Loading...
HomeMy WebLinkAboutREVISION 10-8-18FILE COPY OFFICE USP ONLY: DATE FILED: 14)E. - V5 PERMIT # I90 Ugh 4::' o REVISION FEE: .-75 100 SCANNED RECEIPT # PLANNING & DEVELOPMENT SERVICES BUILDING & CODE REGULATION DIVISION 2300 VIRGINIA AVENUE FORT PIERCE, FL 34982.5652 (772)462.1553 APPLICATION FOR BUILDING PERMIT REVISIONS PROJECT INFORMATION LOCATION/SITE ADDRESS: „SUM 5•c3a$rAft pr . DETAILED DESCRIPTION OF PROJECT REVISIONS: p� Ip Tc>N\ CONTRACTOR INFORMATION: STATE of FL REG./CERT. #: ST. LUCIE CO CERT. #: BUSINESS NAME: QUALIFIERS NAN ADDRESS: Qyc CITY: 0 S�-- PHONE(DAYTIME): 771 - aNS •o'a`b rx OWNER/BUILDER INFORMATION: NAME: _ ADDRESS: CITY: PHONE (DAYTIME: STATE: ARCHITECT/ENGINEER INFORMATION: NAME: ADDRESS: CITY: PHONE (DAYTIME): SLCCC: 9123109 R@vised 06130117 STATE: FAX. — &VV,A" 1 FAX: FAX: REVISION QS1PYD P4.(9 �VKO� I,C4A,-. ZIP: ZIP: GENERAL NOTES PLANS AND ENGINEERING BY IN PAUL WELCH, INC. 1984 SW BILTMORE STREET # 114 PORT SAINT LUCIE, FLORIDA 34984 PHONE: (772) 785-9888 FAX : (772) 785-9933 FILE COPY REVISION planning & Development Services. Department ® Building & Code Regulations Division 2300 Virginia Avenue, Fort Pierce, FL 34982 - (772) 462-1553 Certification for Design Load Compliance ST. LUCIE COUNTY BUILDING DIVISION Project Name: REYES RESIDENCE RED EWED -FOR COMP REVIEWED B Project Address: 56045EAGRAPE DR. DATE PLA S AN PERM UST BE KEPT ON JGB Permit#: Occupancy Type: R ConstructI&JTfpQR NO INSPECTION(S) WILL BE MADE INSTRUCTIONS FOR USE: • This certification must be completed, signed, and sealed by the design professional of record. • Submit (2) copies for residential, (3) copies for commercial with all permit applications involving the following: THESE PLANS AND ALL PROPOSED WORK o New Residences (single or multi -family) o Residential Addition ARE SUBJECT TO ANY CORRECTIONS REQUIRED BY FIELD INSPECTORS THAT o Any accessory structure requiring a building permit MAY BE NECESSARY IN ORDER TO o Any non-residential structure. WMj Q 4k� APPLICABLE CODES. • Note: Form not required for interior renovations provided that no exterior structural eleme - certain minor building permits at the discretion of the local building official. Contact the # above for questions, U„tN'f 5 DESIGN PARAMETERS AND ASSUMPTIONS USED, (complete all that cooly)1. 2. DESIGN CODE: Florida Building Designed as (check one): Code Enclosed Edition -Partially llEnclosed lements uOpe ASC`oM with 7 hVto �Pespo`1�1811� Art 3. Risk Category: _1 X II_III IV Exposure Category: _B X C D QREjfu1�jQf.��jQ1`tq,�F RAC u 4. Design Wind Velocity 165 mph 128 ASD N/A LRFD End Zone Width: 5 ft ,e S. Mean Roof Height: 11.5 ft Roof Pitch: 6 :12 Parapet: N/A ft 6. Components & Cladding Design Pressures Used: (PSF, based on 10sgft @ 15'MRH, clearly label on all plan openings): 20.6 20.6 20.6 35.8 35.8 27.2 Zone 1: -32.7 Zone 2: Zone 3: Zone 4: Zone 5: Garage: _35.4 -57.0 -84.2 -38.8 -07.9 7. Design Loads: Floor: 40 PSF Roof/Dead: 5 PSF Roof/Live: 20 Balcony:. N/A PSF Dock: N/A PSFDeck: N/A PSFStairs: N/A PSF Fence: N/A PSF Railings: N/A PLF/CONCENTRATED 8. Were Shear Walls Considered For Si:ructure? X Yes _Not Applicable Explain Why Not: 9. Is A Continuous Load Path Provided? X Yes -Not Applicable Explain Why Not: 10. Design Soil Bearing Pressure: 2000 PSF Soil Test Reports Submitted? _Yes DESIGN PROFESSIONAL CERTIFICATION STATEMENT: I certify that, to the best of my knowledge and belief, the attached plans & specifications have been designed to comply with the applicable structural portions of the building codes currently adopted and enforced by St. Lucie County. I also certify that structural elements depicted on these plans provide adequate resistance to the design forces specified: 29945 / 5115 Paul Welch P.E. Print Name Cent # & Co. Cart Auth. Paul Welch Inc. ON PLAN 2/19/2018 Signature, Date, and Seal 1984 S.W. Biltmore St. Suite #114 Pc,y Company Name &Address SLCCDV Form # 020-12 Revised 3/15/12 (JS) - _- - FPL SERVICE CONFIRA r I �^ I�(IQQ Tu op pFp�y GARAGE LEFT I\01 4r111 I ;1ATION OF PORT ST LGIE PROPER101I EGENCE EC WRITTEN DIMENSIONS OVER SCALED DIMENSIONS. CONTRACTOR SHALL VERIFY ALL DIMENSIONS. DATE Smalliwrazd Av'q.. Ilk Howard Si ) W ( - a PIP !. 11 to i ' re � ,.. 11013l .01 Iirds#E el `�kzr?r�lnnalx S1 _& v ,U 40 n ib` yt"aF Bari m1N SI Bartow at r CONSTRUCTION BY PORT ST LUCIE PROPERTIES 2401 SW MONTEREY LANE, PORT ST LUCIE, FLORIDA, 34953 MODEL: (772) 336-0050 CONSTRUCTION OFFICE: (772) 249-0089 WWW. PSL PROPERTIESINC. COM ST LUCIE COUNTY, FLORIDA OWNERS NAME BUILDING PERMIT NUMBER: PRODUCT OPENING DESIGN PRESSURES WINDOWS SEE ELEVATIONS WINDOWS N/A MULLIONS N/A BLOCK GLASS N/A SKYLIGHTS N/A SLIDING GLASS DOORS N/A SWING TYPE DOORS SEE ELEVATIONS FRENCH DOORS SEE ELEVATIONS GARAGE DOORS SEE ELEVATIONS HURRICANE PROTECTION N/A ROOF VENTILATION N/A REYES PRODUCT RATED MANUFACTURER DESIGN PRESSURES + / - 55.0 MI WINDOWS & DOORS ` N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A - + 49.2 /- 50.0 THERMA-TRU + / - 50.0 THERMA-TRU + / - 37.0 CLOPAY N/A N/A N/A N/A LLAL1:- 60A� J ROOFING MATERIALS -- MIZ F` r 1 Qgj, ; p jr C20P? I HAVE REVIEWED THE ABOVE COMPONENTS AND CLADDING, AND HAVE APPROVED THEIR USE STRUCTURE TO PROVIDE ADEQUATE TO THE WIND LOADS AND FORCES SPECIFIED BY CURRE NAME: PAUL WELCH, P.E. SIGNATURE: ON PLA DESIGN PROFESSIONAL : PAUL WELCH, INC. CERTIFICATION NO.29945 PROJECT PROPOSED NEW RESIDENCE FOR: REYES 5604 SEAGRAPE DRIVE FORT PIERCE, FLORIDA 34982 MODEL CAYMAN VICINITY MAP SCANN 8Y �' f AM'i6�i�t111fi' ONTENTS data @201 A100 - COVER SHEET All01 - PROPOSED FLOOR PLAN, TYPICAL WALL SECTION, & SOFFIT,DETAIL A102-PROPOSED ELEVATIONS A103 - PROPOSED ELECTRICAL PLAN, LOAD CALCS, AND SYMBOL LEGEND. A104 - PROPOSED FOUNDATION PLAN A105 - PROPOSED BLOCKAND TIE -BEAM PLAN, AND LINTEL SCHEDULE A106 - PROPOSED HVAC PLAN, AC NOTES, AND PLUMBING RISER. A107 - PROPOSED TRUSS PLAN AND CONNECTOR SCHEDULE A108 - PROPOSED CONSTRUCTION DETAILS PORCH COLUMN DETAIL INTERIOR NON -BEARING WALL DETAIL BLOCK TRANSITION DETAIL GARAGE DOOR ATTACHMENT DETAIL ROOF SHEATHING NAILING ZONE DETAIL INTERIOR STEP DOWN BEARING WALL,DETAIL A109 - PROPOSED CONSTRUCTION DETAILS FENESTRATION DETAILS PLANNING & DEVELOPMENT SERVICES DEPARTMENT BUILDING & REGULATIONS DIVISION PRODUCT REVIEW AFFIDAVIT APPLICANT: MODEL NUMBER PRODUCT APPROVAL NUMBER GLASS TYPE METHOD OF ATTACHMENT 185 SH FL # 17499.1 IMPACT 3/16" X 1-1/4" MIN. EMBED TAPCONS AT2"/11"O.C. N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A SMOOTH STAR FL # 7640.2 IMPACT S/L 1/4" X 1-1/4" MIN. EMBED TAPCONS AT 6" / 13.75" O.C. SMOOTH STAR FL # 7640.4 IMPACT 1/4" X 1-114" MIN. EMBED TAPCONS AT 6'/13.75"OC 29W6-10 FL # 567$.29 N/A 5/16" X 1-5/8" MIN. EMBED LAG SCREWS ONE PER BRACKET N/A N/A N/A N/A N/A N/A N/A N/A-� PANEL FASTENER: #9 -15 X 1 Y2" WOODGRIP WITH SEALING WASHER IN THE RIB OF THE PANEL,'/a" MINIMUM PENETRATION THROUGH THE PLYWOOD. ALL FASTENERS TO BE CORROSION RESISTANT. FASTENERS SHALL BE INSTALLED AT 12" PARALLEL TO ROOF SLOPE AND 12" O.C. PERPENDICULAR TO ROOF SLOPE. V 5 I L I N/A THIS - �-1-- --•..,q CODE PROVISIONS. ENGINEER PAUL WELCH INC. PAUL WELCH P.E. REG. # 29945 PORT SAINT LUCIE, FL 34984 PHONE :(772) 785-9888 FAX: (772) 785-9933 Oc i 0 4 201 EMAIL: PWELCHINC@AOL.COM 1)THE CONTRACTOR, SUBCONTRACTOR, SUPPLIER, ECT. SHALL VERIFY ALL DIMENSIONS, CONDITIONS AT JOB SITE, PLANS, SPECIFICATIONS, ECT. 2) STRUCTURAL FEATURES NOT DETAILED ON THESE PLANS WILL BE ADDRESSED BY THE ENGINEER AS CONSTRUCTION PROGRESSES. 3)ALL WRITTEN DIMENSIONS ON THESE DRAWINGS TAKE PRECEDENCE OVER SCALED DIMENSIONS. 4) ALL CONSTRUCTION MUST COMPLY WITH THE FLORIDA BUILDING CODE (FBC) 2017, FBC 2017 RESIDENTIAL, FBC 2017 PLUMBING CODE, FBC 2017 MECHANICAL CODE, FBC 2017 ENERGY CONSERVATION, AND THE NEC (NFPA 70) 2014 EDITION. 5) RESIDENCE LOCATED IN NEGLIGIBLE WEATHERING AREA, AND IN VERY HEAVY TERMITE INFESTATION AREA PER FRO 301. ADDITIONAL NOTES 1) INTERIOR TO BE %" DRYWALL FINISH. 2) ALL INTERIOR GYPSUM BOARD TO BE MIN. Y" THICK WITH (13 GAGE, 1 3/8" LONG, 19/64" HEAD; 0.098" DIAMETER, 1 ''/," LONG, ANNULAR -RINGED; 5D COOLER NAIL, 0.086" DIAMETER, 1 5/8" LONG, 5/64" HEAD; OR GYPSUM BOARD NAIL, 0,086" DIAMETER, 1 5/8" LONG, 9/32" HEAD) SPACED AT 7" O.C. FOR NAILS AND 12" O.C. FOR SCREWS. 3) WALLS AT SHOWER TO BE TILE. PROVIDE CEMENT, FIBER -CEMENT OR GLASS MAT GYPSUM BACKERS IN COMPLIANCE WITH ASTM C 1288, C 1325, C 1178, OR C 1278 AND INSTALLED IN ACCORDANCE WITH MANUFACTURERS' RECOMM EN CATIONS AS BACKERS FOR WALLTILE IN TUB AND SHOWER AREAS AND WALL PANELS IN SHOWER AREAS. (PER FRC 702.4.1 & FRC 702.4.2). 4) WALLAND CEILING FINISHES SHALL HAVE A SMOKE -DEVELOPED INDEX OF NOT GREATER THAN 450. 5) WALLAND CEILING FINISHES SHALL HAVE A FLAME SPREAD CLASSIFICATION OF NOT GREATER THAN 200. 6)ALL EXPOSED INSULATION MATERIALS INSTALLED ON ATTIC FLOORS SHALL HAVE A CRITICAL RADIANT FLUX NOT LESS THAN 0.12 WATT PER SQUARE CENTIMETER. EXPOSED FOAM PLASTIC INSULATION MATERIALS EXPOSED TO THE UNDERSIDE OF THE ROOF DECK OR ON THE ATTIC WALLS SHALL COMPLY WITH SECTION FRC316. 7) PER FRC 702.2.1 ALL GYPSUM BOARD MATERIALS AND ACCESSORIES SHALL CONFORM TO ASTM C 36, C 79, C 475, C 514, C 630, C 931, C 960, C 1002, C 1047, C 1177, C 1178, C 1278, C 1395, C 1396 OR C 1658 AND SHALL BE INSTALLED IN ACCORDANCE WITH THE PROVISIONS OF FRC, AND ADHESIVES FOR THE INSTALLATION OF GYPSUM BOARD SHALL CONFORM TO ASTM C 557 8) INSULATION MATERIALS, INCLUDING FACINGS, SUCH AS VAPOR RETARDERS OR VAPOR PERMEABLE MEMBRANES INSTALLED WITHIN FLOOR -CEILING ASSEMBLIES, ROOF -CEILING ASSEMBLIES, WALL ASSEMBLIES, CRAWL SPACES AND ATTICS SHALL HAVE A FLAME SPREAD INDEX NOT TO EXCEED 25 WITH AN ACCOMPANYING SMOKE -DEVELOPED INDEX NOT TO EXCEED 450 WHEN TESTED IN ACCORDANCE WITH ASTM E 84 OR ILL 723. STRUCTURAL NOTES 1) DESIGN LOADS IN ACCORDANCE WITH ASCE7-10. 2) SOIL BEARING CAPACITY: 2000 PSF (MIN.). 3) ALL STRUCTURAL CONCRETE IN BEAMS, LINTELS, VERTICAL CELLS, AND COLUMNS SHALL HAVE A MINIMUM COMPRESSIVE STRENGTH OF 3000 PSI COMPRESSIVE STRENGTH AT 28 DAYS. 4) SLAB / FOOTINGS TO BE CONCRETE WITH A MINIMUM 2500 PSI COMPRESSIVE STRENGTH AT 28 DAYS. SEE PLAN FOR SIZES & STEEL REQUIREMENTS, 5) MINIMUM CONCRETE PROTECTION FOR REINFORCING BARS: FOOTINGS: YBEAMS: 1 'W'SUSPENDED SLABS: 1 W' 6) LAP ALL REINFORCING STEEL MINIMUM OF 48 BAR DIAMETERS EXCEPT AS NOTED GRADE 60 STEEL MINIMUM IN BEAMS AND COLUMNS, 7) ALL LUMBER IN CONTACT WITH CONCRETE OR MASONRY SHALL BE PRESSURE TREATED. 8) SPLITING OR CRACKING OF STRUCTURAL COMPONENTS DUE TO INSTALATION OF HARDWARE IS NOT PERMITED. 9) UNLESS OTHERWISE NOTED, THE INSTALLATION OF SPECIFIED HARDWARE SHALL CONFORM TO THE MANUFACTURES INSTRUCTIONS AND STANDARD PRACTICES 10) UNLESS OTHERWISE NOTED, FOR EXTERIOR WALLS, EXTERIOR PLYWOOD SHEATHINGAND INTERIOR DRYWALL IS TO BE NAILED WITH 10d OR BETTER NAILS 6" O.C. EDGES, AND 6" O.C. FIELD, OR SCREWED WITH DRYWALL SCREWS 1.5" LONG AND 0.131 DIA. 11) LINTELS SHALL HAVE A MINIMUM 4" BEARING EXCEPT RECESSED LINTELS SHALL HAVE 8" BEARING, 12) PROVIDE # 5 CORNER BARS W/ 30" MIN. LAP SPLICE FOR BOND BEAM. 13) EXTERIOR FRAME WALLS TO BE STUCCO OVER WIRELATH WITH 11 GA. 2" LONG NAILS WITH 3/8" 0 HEAD @ 6" O.C. OVER (2) LAYERS OF (15# FELT OR TYVAK BUILDING WRAP) OVER 19/32" CDX PLYWOOD WITH 10D NAILS TO STUDS @ 6" O.C. PERIMETER AND FIELD. 14) BEARING POINTS OF TRUSSES SHALL HAVE VERTICAL STUDS IN A NUMBER EQUAL TO THE NUMBER OF PLIES OF THE BEARING MEMBER WHEN THE BEARING MEMBER IS (2) OR MORE PLIES UNLESS NOTED. ENERGY CONSERVATION NOTES 1) RESIDENCE SHALL BE IN ACCORDANCE WITH FLORIDA BUILDING CODE 2017 ENERGY CONSERVATION RESIDENTIAL. 2) ATTIC ACCESS DOORS OR HATCHES FROM CONDITIOND SPACES TO UNCONDITIONED SPACES SHALL BE WEATHERSTRIPPED AND INSULATED TOALEVEL EQUIVALENT TO THE INSULATION ON THE SURROUNDING SURFACES, A WOOD FRAMED OR EQUIVALENT BAFFLE OR RETAINER IS REQUIRED TO BE PROVIDED WHEN LOOSE FILL IS INSTALLED, TO PREVENT LOOSE FILL FROM SPILLING INTO THE LIVING SPACE. 3) THE BUILDING THERMAL ENVELOPE SHALL BE CONSTRUCTED TO LIMITAIR LEAKAGE IN ACCORDANCE WITH THE REQUIREMENTS R402.4.1 THROUGH R402.4.4. 4) WINDOWS, SKYLIGHTS, AND SLIDING GLASS DOORS SHALL HAVE AN AIR INFILTRATION RATE OF NO MORE THAN 0.3 CFM PER SQUARE FT, AND SWINGING DOORS NO MORE THAN 0.5 CFM PER SQUARE FT AND MUST BE TESTED LISTED AND LABELED IN ACCORDANCE WITH R402.4.3. 5) CONTRACTOR SHALL PROVIDE ENERGY PERFORMANCE LEVEL (EPL) DISPLAY CARD IN ACCORDANCE WITH FBC 2014 ENERGY CONSERVATION R401.3. ELECTRICAL NOTES 1) ALL ELECTRICAL WORK SHAL BE IN ACCORDANCE WITH FHE NEC (NFPA 70) 2014 EDITION. 2) A MINIMUM OF 75% OF THE LAMPS IN PERMANENTLY INSTALLED LIGHTING FIXTURES SHALL BE HIGH-EFFACY LAMPS OR MINIMUM OF 75% OF THE PERMANENTLY INSTALLED LIGHTING FIXTURES SHALL CONTAIN ONLY HIGH-EFFACY LAMPS. (LOW VOLTAGE LIGHTING SHALL NOT BE REQUIRED TO BE HIGH-EFFACY LAMPS) 3) RECESSED LIGHTING SHALL BE SEALED TO LIMIT AIR LEAKAGE BETWEEN CONDITIONED AND UNCONDITIONED SPACES, 4) SMOKE DETECTORS TO BE 110V W/ BATTERY BACK UP -ARC FAULT CIRCUIT 5) SMOKE DETECTORS TO BE INTERCONNECTED SO THAT ONE SMOKE DETECTOR ACTIVATES ALL SMOKE DETECTORS IN THE RESIDENCE 6) PROVIDE BRANCH CIRCUITARC-FAULT PROTECTION FOR ALL CIRCUITS SERVING: FAMILY ROOMS, DINING ROOMS, LIVING ROOMS, PARLORS, LIBRARIES, DENS, BEDROOMS, SUNROOMS, RECREATION ROOMS, CLOSETS, HALLWAYS, OR SIMILAR ROOMS PER FBC AND NEC REQUIREMENTS. 7) PROVIDE GROUND -FAULT CIRCUIT INTERRUPTER PROTECTION FOR ALL 125-VOLT, SINGLE-PHASE 15 AND 20 AMP CIRCUITS SREVING: BATHROOMS, GARAGES, KITCHENS, ACCESORY BUILDINGS, OUTDOORS, OR WITHIN 72" OF EDGE OF ANY SINK. 8) CARBON MENOXIDE DETECTORS TO BE INSTALLED WITHIN W' OF ALL BEDROOMS. 9) EXHAUST FANS TO BE VENTED THRU ROOF OR SOFFIT. 10) PROVIDE TAMPER RESISTANT RECPTICLES PER NEC REQUIREMENTS. PORT ST LUCIE PROPERTIES 2401 S1t( MONTEREY LANE, PORT ST LUCIE, FLORIDA, 34953 WWW.PSLPROPERTIESINC.COM N 16'-0" ■ ■ -- ■ TRUSSED ROOF PORCH 8'1 FLAT CEILING - - SCREEN ENCLOSED, CONTRACTOR TO LOCATE SCREEN DOOR " I ; I I I 3112 STEP SH-25 / EGRE`:S 60681 TEMP. /.SGD ■ ■ ■ ■ ■ ■ ■ — ■ ■ ■ NJ imir ■ TILED SHOWER 10'-9'/:' LRI.F. 2 -- - - - - -- V DW 11'-10 U 3-1/2"STEP ' \' LL M 11,_7„ i Li p we I g s ORE CEILINGFRo 8'-0"TO9'-4" — _ — — — KITCHEN— — 3 o ° " BEDROOM # 3 U = 6-1,/." O - - — — — — — _ - — w — o 8'-0"FLAT CEILING Z ,n ■ O co o O OO o DRAWER BATH w "z Y W STACK DINING Q J M I O Q '_61 e m w _ W cwi I 'T WALLCABINETS m � m ti a ih ®` -I N W S LL 36" HIGH 5-1/2" WALL " LL 2668 •" f.. o O COUNTER WASHER DRYER W/ VTR Y 4 Q "� i. t7 OCATION LOCATION 4'-BY4"Lu M T-11/4" LL ■■ `o� M-1 DOBEN'-1I1. II II n TILIT5YC6iL" OSE�TW WARr — — — 5068 BF 34-1/2" KNEE WALL R -RO5D06&8S/HBEIFLOFM HCIII o GREATROOMNON-BRG—m ea•FLAATELINIi CLOSET — — — — — 9-4" FLAT CEILING HEADER/CAMBER ------ 51 L�oN + NON ERG WALL � - w 2 N q I I T-9" 1'-8 a" I x� I a z ■ -1n 1 e a i 1 fh I M fM Z_ c I iy 3r.5n WH WH w/ DRIP PAN r 5'-1'/a" 6'-6Y2" o O & DRAIN LINE - 3-1/2" STEP EO M lIfo " PROTECTI N POST CC 1 c 3'-11 y" = " SLOPE CEILING FROM 8'-0" O 9'-4" x \ WC BATH ■ OD z n 2" CURB i� FPL METER 2" URB BoTToM cI IORD BEARING BEYOND WALL ; NON sevQ D WALL AHu Lou rE0 w nrrlc -H FOYER a� BEARING WALL-' F w/ DRIP PA 11 &DRAIN LINE A > ' N 19'-4Y,," b E 150AMP rn , UTILITY PAD ELECT. PANEL -- N TUB /SHOWER W INSULATE WALL W/ R-11 FIG BATT 3068 / 14"TEMP. SL w A/C COND. ■ ■ ■ ■ ■ ■P NJ LL Is ■ ■ W L ' .....--::. . - _. -._..- _....... ■ i 3 l2"STEP h W O OIRDER BY TRUSS CO. SH-35 /COI It Q CD i� , F : MAIN EGRESS DOOR iv BEDROOM #2 �t 8'-0"FLATCEILING ■ 71'-10" o GARAGE ■ ■ N LL N 8 N F(LAT A.F.F.) !LING o COVERED ENTRY / FRONT PORCH sH-25 / EGRESS/ COL. O = I 3'-6° iD it 9'-4" FLAT CEILING w o ----------- --------------------------------- a Eo I ■ a. --- -- -- ------- ---- ■ w , _ _ _ _ PRECAST UN—Til`- r IA 101 W -- - ------------------ 12' X 12" CMU COL MN 50 a (3 LOCATIONS) wo N HOSE BIBB Q ?E I fV� ■ a0 ' ■ 4'-0" OCCUPIED CUBIC FOOTAGE = 14882.95 CALCULATE ATTIC VENTILATION CEILING = 2020 SQUARE FEET 2020 1300 = 6.7333 REQUIRED VENTILATION 192.0 LINEAR FEET OF W X 22"VENTS @ 48" O.C. = 44.0 SQ. FT. 12 = 22.0 SQUARE FEET AVAILABLE FOR CROSS VENTILATION. 22.0 SQUARE FEET> 6.7 SQUARE FEET: SOFFIT VENTILATION OK PROVIDE 6"X 22" SOFFIT VENTS 0 48" ON CENTER REQUIRED VENTING IN THE UPPER PORTION OF THE ATTIC- 40 - 50 % OF REQUIRED VENTING AS PER FRC 806.2 EX #2 6.733 X 40% = 2.693 SQ. FT. OF RIDGE VENT 6.733 X 50% = 3.367 SQ. FT. OF RIDGE VENT RIDGE VENT 18 LINEAR FEET OF 2" VENT = 3.0 SQUARE FEET OF RIDGE VENT PROVIDE 18 LF OF RIDGE VENT 12 �6 2" X 6" PRIMED & PAINTED IRIS SPRUCE 12 O. . o 6" X 22" VENTS AT 4'-0" O.C. - STUCCO OVER WIRE LATH w/ 11ga. 2" NAILS WITH 3/8" FFIT DET IL HEAD DIA. AT 6" O.C. OVER :ALE 3/8" RIB LATH @ 6" O.C. WITH (2 LAYERSOF 15 # FELT OVER EACH FRAMING MEMBER) 1 PRE-ENGINEERED ROOF TRUSSES @ 24" O.C. COVERED BY 19/32" 4 PLY COX PLYWOOD (SEE NAILING DETAIL) HETA20 HURRICANE ANCHORS EMBEDDED 4" INTO BEAM FOR TRUSSES 12 NN .SCHEDULE) 61 Y0 �4!5V Mg � OVER 30 It ROOFING FELT R-30 TYPICAL CEILING INSULATION CONT. GALV. MTL DRIP OVER (PT)1X2 - -- --- 8°. �1/2" DRYWALL @ CEILING (TYPICAL) 8" X 8" X 16" BEAM BILK. 2" X 6" PRE -PRIMED 112" D.H./ (1) # 5 BAR IN 3000 PSI SPRUCE FASCIACONCRETE FILLED CELL VENTED 8" PRECAST LINTELS STUCCO SOFFIT W/( # 5 BAR FOR ALL O (SEE DETAIL) DOOR AND WINDOW OPENINGS LL & FILLED W/ 3000 PSI CONCRETE p STUCCO FINISH W 1"X 2" P.T. FURRING STRIPS - 0 @ 16" O.C. WITH FI-FOIL z VERTICAL REBAR TIED TO DOWEL INSULATION L` & RUNNING INTO BEAM BLOCK o IN 3000 PSI CONC. 1/2" DRYWALL x (TYPICAL) ILL. VERTICAL DOWELS W/ 30" LAP SPLICE 8" CONCRETE BLOCKS FROM FOOTER WOOD BASE BOARDS (SEE FOUNDATION PLAN FOR SIZE & SPACING ) 8° 4" CONC. SLAB (MIN. 2500 PSI) -0" TOP OF SLAB w/ 6 X 6 10/10 WWM OR FIBERMESH I GRADE TYPICAL WALL SECTION (CONCRETE BLOCK I LINTEL U-BLOCK CONSTRUCTION) NO SCALE ROOD CONCERT DRAWING SCALE : 3116" = V-0" " W y co 2 NINE a M O J Q Z NLLJ W w o ILL! UJIH F- � w _ O W O W � Ja•I L T � u) O � eg 0 " ° cz n. O L PROPOSED REYESRESIDENCE 5604 SEAGRAPE DRIVE FORT PIERCE FLORIDA 34982 PLAN INFORMATION, A SINGLE FAMILY RESIDENCE MODEL CAYMAN GARAGE SIDE LEFT ELECTRICAL SERVICE EXPOSURE 160-C PLAN DIMENSIONS 58'-0"X 38'-O" AREA TABULATIONS LIVINGAREA 1376.0 SQ. FT. GARAGE 420.0 SQ. FT. ENTRY 96.0 SQ. FT. BACK PORCH 128.0 SQ. FT. TOTAL FOOTPRINT 2020.0 SQ, FT. .COPYRIGHT REMAINS THE PROPERTY OF.PORTST LUCIE PROPERTIES INC. WRITTEN DIMENSIONS TAKE PRECEDENCE OVER SCALED DIMENSIONS,CONTRACTOR SHALL VERIFY ALL DIMENSIONS ON SITE. SHEET INDEX A100 - COVER SHEET A101 --FLOOR PLAN A102 - ELEVATIONS A103 - ELECTRICAL PLAN A104 - FOUNDATION PLAN A105 - BLOCK PLAN A106- HVAC PLAN A107 - TRUSS PLAN A108- DETAILS A109 - DETAILS SHEET INFORMATION DATE JANUARY 29, 2018 DRAWN BILL SCHROEDER REVIEWED SCALE 114" = 1'-0" REVISIONS ENGINEER OF RECORD PAUL WELCH INC. PAUL WELCH P.E. REG. # 29945 1984 SW BILTMORE STREET PORT SAINT LUCIE, FL 34984 PHONE: (772) 785-9888 FAX: (772) 785-9933 EMAIL: PWELCHINC@AOL.COM SHEET Al 01 BEARING HT. 9'-4" (ENTRY) BEARING HT 8'-0" zL OPENING LD. A FINISHED FLOOR 0'-0" 0'I F SCALE: 1/4" = l'-0" 77777 OPENING LD. NT ELEVATION_ B oPENCNG LD. NOTE: 41 31 SAND FLOAT FINISH 12" X 12" ON ALL STUCCO BANDS & CCOLUMN RETURNS SUCH AS WINDOWS, (TYPICCAA L (3) PLACES) 5, DELIGHT DOORS, GARAGE DOORS, 1 I AND ENTRY CALCULATE ATTIC VENTILATION CEILING = 2020 SQUARE FEET 2020 / 300 = 6.7333 REQUIRED VENTILATION 192.0 LINEAR FEET OF 6" X 22" VENTS @ 48" O.C. = 44.0 SQ, FT. / 2 = 22.0 SQUARE FEET AVAILABLE FOR CROSS VENTILATION. 22.0 SQUARE FEET> 6.7 SQUARE FEET: SOFFIT VENTILATION OK PROVIDE 6"X 22" SOFFIT VENTS (a), 48" ON CENTER REQUIRED VENTING IN THE UPPER PORTION OF THE ATTIC 40 - 50 % OF REQUIRED VENTING AS PER FRC 806.2 EX #2 6.733 X 40% = 2.693 SO. FT. OF RIDGE VENT 6.733 X 50% = 3.367 SQ. FT. OF RIDGE VENT RIDGE VENT 18 LINEAR FEET OF 2" VENT = 3.0 SQUARE FEET OF RIDGE VENT PROVIDE 18 LF OF RIDGE VENT BEARING HT 8'-0" FINISHED FLOOR 0'-0" (;1 18 LF RIDGEVENT -- �. BEARING HT 8'-0" FINISHED FLOOR 0'-0" OPEND 3I 12 6 OPENING I.D. E z w A SCALE: 1/4" = l'-O" BEARING HT 9'-4" BEARING HT 8'-0" FINISHED FLOOR 0'-0" SCALE: 1/4" = l'-O" _ FINISHED FLOOR 0_0" OPENING I.D. F _21 18' L.F. APPLIED DESIGN PRESSURES (PSF) MARK I E ZONE 4 ZONE 5 (+) H (+) H 1 10 35.8 -38.8 35.8 -47.9 2 15 35.7 -38.7 35.7 -47.7 3 1 20 35.6 -38.6 35.6 -47.5 4 25 35.5 -38.5 35.5 -47.3 5 30 35.4 -38.4 35.4 -47.1 6 35 35.3 -38.3 35.3 -47.0 7 110 1N/A N/A 1 2.7.2 -35.4 OPENING I.D. OPENH G I.D. 31 31 I u 14416 BEARING HT SCREEN NOT SHOWN " FINISHED FLOOR 0'-0"_ Tu M � Z ou Z U i Q Z !!ww Y+ W �0W � LL rw W 0uia W �a U) U) a. 4. O H O CV O a PROJECT'' PROPOSED REYES RESIDENCE 5604 SEAGRAPE DRIVE FORT PIERCE FLORIDA 34982 A SINGLE FAMILY RESIDENCE MODEL CAY GARAGE SIDE I ELECTRICAL SERVICE EXPOSURE 1 PLAN DIMENSIONS 58'-0"X3 AREA TABULATIONS LIVING AREA 1376.0 SQ GARAGE 420.0 SQ ENTRY 96.0 SQ BACK PORCH 128.0 SQ TOTAL FOOTPRINT 2020.0 SQ. COPYRIGHT REMAINS THE PROPERTY OF PORT ST LUCIE PROPERTIES INC. WRITTEN DIMENSIONS TAKE PRECEDENCE OVER SCALED DIMENSIONS,CONTRACTOR SHALL VERIFY ALL DIMENSIONS ON SITE. SHEETINDEX A100 - COVER SHEET A101 - FLOOR PLAN A102 -ELEVATIONS A103 - ELECTRICAL PLAN Al04- FOUNDATION PLAN A105 - BLOCK PLAN A106 - HVAC PLAN A107 - TRUSS PLAN A108 - DETAILS A109 - DETAILS DATE SEPTEMBER 25, 2 DRAWN BILL SCHROEL REVIEWED SCALE 114" _ REVISIONS ENGINEER OF RECORD PAUL WELCH INC. PAUL WELCH P.E. REG. # 29945 1984 SW BILTMORE STREET PORT SAINT LUCIE, FL 34984 PHONE: (772) 785-9888 FAX: (772) 785-9933 EMAIL: PWELCHINC@AOL.COM OCT 0 4 2018 SHEET A102