Loading...
HomeMy WebLinkAboutDESIGN PRESSURE CALCULATIONSDATE: 4/18/18 CLIENT: Tradewinds ADDRESS: PO Box 132( PROJECT: Starshine Pr ADDRESS: 373 NE Bra( SCANNED RECEIVED APR 2 0 018 ST. WOP cownty, Permitting ofing, Inc. Fort I erties Flat n Road I Port c 2017 FBC/ASCE-7 DESIGN Project Information: Height = 12' Exposure: C Length = 17' Category: H Width = 11' Slope: < 7° Parapet Wall: N/A Residential Design Calculations: Velocity Pressure: q = 0.00256*KZKZt] Velocity Pressure („ lt): q=0.00256(0.8' Velocity Pressure (.d): q=0.00256(0.8 ENGINEERING & TESTING, INC. Phone: (866) 781-6889 •Fai.: (866) 784-8550 www.tlo ridaengineeringandtesting.com 250 S.W.13"' Avenue Pompano Beach, FL 33069 #: 18-1629 Deck SSURE CALCULATIONS Basic/Ultimate Wind Speed: V„It=170 mph Nominal Wind Speed: V.d=Vwt*q0.6 (asd = allowable strength design) KZ = 0.85, Kzt =1.0, Kd = 0.85 1.0)(0.85)(170)2 = 53.45 psf ;1.0)(0.85)(170*40.6)2 = 32.07 psf Width of Pressure Coefficient: 0.1(1 F) = 1.1' 0.4(�12') = 4.8' } use: 3'0' Effective Wind Area: <10ft2 For parapet height three feet (T) or arger, zone three (3) shall be treated as zone two (2). External Pressure Coefficient: Internal Pressure Coefficient: 1) GCP1 = -1.0 1) GCP; = 0.18 2) GCP2 = -1.8 3) GCP3 = -2.8 Loge 'DNA v�Q v �\'��� .flsmcrdnee Page 2, 4/18/18, Job Order #1'. �.,'` i29 Tradewinds Roofing, Inc. Starshine Properties Flat Wood Non -Insulated Deck 373 NE Bracken Road; Port Saint Lucie, FL: Design Pressures Based on Vasd: 1) Field P1 = 32.07*1(-1.0) — (0.18)] _ -37.8 psf 2) Perimeter P2 = 32.07*[(-1.8) — (0.18)] _ -63.5 psf 3) Corners P3 = 32.07*�(-2.8) — (0.18)] _ -95.6 psf Attachment Requirements Per RAS-117: FLO A Based on the requirements of Florida Product Spproval # FL1046-R8, Appendix 1, Page 6 of 22, System No. W-11, with a maximum Design pressure of-52.5psf; the following are our recommended fastening patterns to attach the proposed two plies of PermaPly 28 or Ventsulation base sheet to the minimum 19/32" plywood deck utilizing approved 11 ga. annular ring shank nails and 32ga., 1-5/8" diameter tin caps: Field: 9" o.c. @ 4" laps and 2 Perimeter: 9" o.c. @ 4" laps and 3 Corners: 9" o.c. @ 4" laps and 4 Notes: Corners and perimeter area rows 12" o.c. rows 9" o.c. rows 9" o.c. shall not be less than a = 3'0" Contractor to verify that the fastening patterns meet manufacturer's requirements for issuance of a arranty (as applicable). All work shall be in compli ce with the local building code product control notice of acceptance and manufacturer specifications and Florida Building Code 2017 Edition. Wind load calculations based on ASCE-7, 2017 FBC and information provided by client. Client 11 responsible for verifying existing/proposed conditions/decks as it pertains to the above provided product approval. All work shall be representative) or a with specifications. ielIed by our field engineer (or authorized ing department inspector to verify compliance \; \%%11111 I/11i,Z N K A Sincerely,,y c�cFy r` Cq �WC ° 0 o Mark A. Mesian'`. p� e Florida Engineerin,sIt g, Ino.� e� Florida Reg. No. 48Y(d2s,QONGMe"a� 0%% Certificate of Authorization RU. 6923