HomeMy WebLinkAboutPRODUCT APPROVAL ROOFING UNDERLAYMENTSFlorida Building Code Online
Page 1 of 2
PANNE
N Dist
) y"h11i 1'[ -t- '.± of i .11 A .. °i-111 L.Nmpp pq
fib..:-......__,_,.._.a_.�.-,..-^—
BCIS Home i Log In User Registration
Florida
Product Approval
USER: Public User
Product Approval Menu >
FL #
Application Type
Code Version
Application Status
Comments
Archlved
Product Manufacturer
Address/Phone/Email
Authorized Signature
Technical Representative
Address/Phone/Email
Quality Assurance Representative
Address/Phone/Email
Category
Subcategory
Compliance Method
s
Hot Topics ! Submit Surcharge i Stats & Facts i Publications I FBC Staff BCIS Site Map 1 Unks I Search i
Florida Engineer or Architect Name wl
the Evaluation Report
Florida License
Quality Assurance Entity
Quality Assurance Contract Expiration
Validated By
Certificate of Independence
Referenced Standard and Year (of
> Application List > Application Detail
FL2569-R14
Revision
2017
Approved
Soprema, Inc. (Canada)
1640 rue Haggarty
Drummondville, NON -US 00000
(819) 478-2400
memathieu@sop rema. ca
Marc -Etienne Mathieu
memathieu@soprema.ca
Marc -Etienne Mathieu
1688 Jean-Berchmans-Michaud
Drummondville, NON -US 00000
(819) 478-2400 Ext3327
memathieu@soprema.ca
Jean -Francois Cote, Ph.D.
1640 rue Haggarty
Drummondville
(888) 811-3145
jfcote@soprema.ca
Roofing
Underlayments
RECEIVED
APR 2 0 2018
ST. Lucie County, Permitting
Evaluation Report from a Florida Registered Architect or a Licensed
Florida Professional Engineer
1 1 Evaluation Report - Hardcopy Received
developed Robert J. M. Nieminen
PE-59166
UL LLC
07/18/2020
John W. Knezevich, PE
ki Validation Checklist - Hardcopy Received
FL2569 R14 COI 2018 O1 COI N.I._EMINEN pdf
Standard
Year
ASTM D1970
2015
ASTM D4798
2011
ASTM D6163
2008
FM 4474
2U11
FRSA/TRI April 2012 (04-12)
2012
UL1897
2012
httD://www..floridabuildin..org/Dr/pr app
aspx?param=wGEVXQwtDgsKQFEnckB 10... 4/20/2018
Florida Building Code Online
Page 2 of 2
Equivalence of Product
Certified By
Sections from the Code
Product Approval Method
Date Submitted
Date Validated
Date Pending FBC Approval
Date Approved
Summary of Products
Method 1 Option D
02/12/2018
02/14/2018
02/17/2018
04/10/2018
FL #
Model, Plumber Jr
Description
Name
2569.1
Soprema Roof
Self adhering roof underlayments
Underlayments
Limits of Use
Approved for use in HVHZ:No
Installation Instructions
FL2569 R14 II 2018 02 FINAL ER SOPREMA CA UNDERLAYMENTS FL2569-
Approved for use outside HVH : Yes
R14pdf
Impact Resistant: N/A
Verified By: Robert Nieminen, P.E. PE-59166
Design Pressure: +N/A/-150
Created by Independent Third Party: Yes
Other: 1.) Refer to ER Section 5 or
Limits of Use. 2.) The design pressure
Evaluation Reports
FL2569 R14 AE 2018 02 FINAL ER SOPREMA CA UNDERLAYMEf�S FL2569_
Rp14.f
noted herein pertains to underlay ent
systems used beneath adhesive -se tile
Created by Independent Third Party: Yes
systems. Refer to ER Section 5.6.4 for
details.
Back N—
Co ta8t Us :: 2601 Blair Stone Road Tallahassee FL 32399 Phone: 850-487-1824
The State of Florida is an AA/EEO employ r. copyr]oht 2007-2013 State of Florida.:: Privacy Statement :: Accessibility Statement :: Refund Statement
Under Florida law, email addresses are pub] c records. If you do not want your e-mail address released in response to a public -records request, do not send
electronic mail to this entity. Instead, cantac the office by phone or by traditional mall. If you have any questions, please contact 850.487.1395. 'Pursuant to
Section 455.275(1), Florida Statutes, effective ctober 1, 2012, licensees licensed under. Chapter 455, F.S. must provide the Department with an email address if
they have one. The emalls provided may be used for official communication with the licensee. However email addresses are public record. If you do not wish to
supply a personal address, please provide the De artment with an email address which can be made available to the public. To determine if you are a licensee under
Chapter 455, F.S., please click here .
Product Approval Accepts:
tom' Ej
Credit Card
Safe
httn://www.floridabuildin..ora/pr/pr app dt .aspx?param=wGEVXQwd)gsKQFEnckB 10... 4/20/2018
ENGINEER EVALUATE
Soprema, Inc.
1640 rue Haggerty
Drummondville, QuebecJ2C5P8 Canada
(819) 478-2400
NEMO etc.
Certificate of Authorization N32455
353 Christian Street, Unit #13
Oxford, CT 06478
(203)262-9245
TEST CONSULT CERTIFY
Evaluation Report S18010.06.09-1112
FL2569-R14
Date of Issuance: 06/15/2009
Revision 12: 02/12/2018
SCOPE:
This Evaluation Report is issued under Rul 61G20-3 and the applicable rules and regulations governing the use of
construction materials in the State of Florid . The documentation submitted has been reviewed by Robert Nieminen,
P.E. for use of the product under the Flor da Building Code and Florida Building Code, Residential Volume. The
products described herein have been eval ated for compliance with the eh Edition (2017) Florida Building Code
sections noted herein.
DESCRIPTION: Soprema Roof
LABELING: Labeling shall be in accordance v
herein.
CONTINUED COMPLIANCE: This Evaluation Repo
Quality Assurance documentation changes, c
this Evaluation Report by the named client
the product(s), the Quality Assurance or the
this Evaluation Report relative to updated Cc
ADVERTISEMENT: The Evaluation Report nurn
advertising literature. If any portion of the E
INSPECTION: Upon request, a copy of this enti
its distributors and shall be available for insp
This Evaluation Report consists of pages 1
Prepared by:
the requirements of the Accredited Quality Assurance Agency noted
is valid until such time as the named product(s) changes, the referenced
provisions of the Code that relate to the product change. Acceptance of
institutes agreement to notify Robert Nieminen, P.E. of any changes to
roduction facility location(s). NEMOletc. requires a complete review of
e requirements with each Code Cycle.
it preceded by the words "NEMOJetc. Evaluated" may be displayed in
luation Report is displayed, then it shall be done in its entirety.
Evaluation Report shall be provided to the user by the manufacturer or
atlon at the job site at the request of the Building Official.
Robert J.M. Nieminen, P.E.
Florida Registration No. 59166, Florida DCA ANE1983
CERTIFICATION OF INDEPENDENCE:
1. NEMO ETC, LLC does not have, nor does it intend
distributing products it evaluates.
2. NEMO ETC, LLC is not owned, operated or controllel
3. Robert Nieminen, P.E. does not have nor will acquit
which the evaluation reports are being issued.
4. Robert Nieminen, P.E. does not have, nor will acqui
product.
5. This is a building code evaluation. Neither NEW
project on which this Evaluation Report, or previou
specifically for that purpose.
8.
.�QS <-'V
•.,fig
The facsimile seal appearing was authorized by Robert
, , a ��^. ,.:;:•
Nieminen, P.E. on 02/12/2018. This does not serve as an
electronically signed document
acquire or will it acquire, a financial interest in any company manufacturing or
by any company manufacturing or distributing products it evaluates.
e, a financial interest in any company manufacturing or distributing products for
e, a financial interest in any other entity involved in the approval process of the
etc. nor Robert Nieminen, P.E. are, in any way, the Designer of Record for any
versions thereof, is/was used for permitting or design guidance unless retained
ROOFING COMPONENT EVALUATION:
Product Category: Roofin
Sub -Category: Under
Compliance Statement: Roof Unde
following sections of the eth Edition
Standards. Compliance is subject t
herein.
ayments, as produced by Soprema, have demonstrated compliance with the
!017) Florida Building Code through testing in accordance with the following
the Installation Requirements and Limitations / Conditions of Use set forth
Section
1504.3.1
1504.3.1
1507.2.4 / 1507.1.1, 1507.2.9.2
1507.3.3
FRSA/TRI April 2012 (04-12).
TAS 110
Pro a
Wind esistance
Wind plift
Physic I Properties
Physic I Properties
Physical Properties
Accele ted Weathering
Standard
FM 4474
UL 1897
ASTM D1970
FRSA/TRI April 2012
ASTM D6163
ASTM D4798
Year
2011
2012
2015
2012
2008
2011
Enti
Exami ation
Reference
Date
ERD (TST6049)
ASTM C{1970 /TAS 110
2969.05.04-2
05/14/2004
ERD (TST6049)
Physics Properties
2757.02.05
02/03/2005
ERD (TST6049)
ASTM D1970 /TAS 110
2974.03.05-2
05/17/2005
ERD (TST6049)
Wind Resistance
2778.07.05
07/15/2005
ERD (TST6049)
Wind R sistance
2779.11.05-111
04/18/2007
ERD (TST6049)
TAS 103 /TAS 110
57120,11.07-2
11/02/2007
ERD (TST6049)
ASTM D 970 / TAS 110
513190.02.09-111
04/01/2010
ERD (TST6049)
ASTM D 970 / TAS 110
531370.03.10-1-R1
04/07/2010
ERD (TST6049)
Physical Properties / Tensile Adhesion
511150.05.10-R1
09/09/2010
ERD (TST6049)
Physical Properties / Tensile Adhesion
511150.05.09-R2
10/05/2010
ERD (TST6049)
ASTM D 970
537210.11.11
11/09/2011
ERD (TST6049)
ASTM D 970
540540.02.13-1
02/19/2013
ERD (TST6049)
Physical Properties / Tensile Adhesion
543530.02.14-1
02/21/2014
ERD (TST6049)
Physical / Tensile Adhesion
SOPC-SC7645.02.15
02/13/2015
ERD (TST6049)
(properties
Accelerated Weathering
SOPC-SC8520.14
04/17/2015
ERD (TST6049)
Wind Resistance
SOPC-SC14045.05.17-RI
06/07/2017
M-D (CER1592)
HVHZ Compliance
15-0508.04
09/24/2015
ICC-ES (EVL2396)
2015 IBC Compliance
ESR-1524
03/01/2017
PRI (TST5878)
Physical roperties
SOP-064-02-01
12/03/2013
Soprema, Inc. (PDM3511)
Equivalency Declaration
SA SMOOTH PLY 40
06/29/2015
UL, LLC (QUA9625)
Quality �ntrol
Service Confirmation
Exp. 07/18/2020
4.1 Lastobond TU HT. is a self-adheri g, non -woven polyester fabric surfaced, SBS modified bitumen roof
underlayment; meets ASTM D1970 and FRSA/TRI April 2012 (04-12).
4.2 Lastobond Shield is a self -adhering, oven polyethylene surfaced, SBS modified bitumen roof underlayment
available in two widths; 36 and 45 inch;l meets ASTM D1970.
4.3 RESISTO SA SMOOTH PLY 40 is a self -adhering, woven polyethylene surfaced, SBS modified bitumen roof
underlayment; available in 3.3 ft x 65 ftirolls; meets ASTM D1970.
4.4 Lastobond Shield HT is a self -adhering, I oven polyethylene surfaced, high temperature, SBS modified bitumen roof
underlayment; meets ASTM D1970.
NEiml;o ETC, Lt_C Evaluation Report S18010.06.09-1112
Certificate of Authorization fi32455 5H EDIT ON (2017) FBC NON-HVHZ EVALUA710N FL2569-R14
Soprema Roof Underlayments Revision 12: 02/12/2018
Page 2 of 8
4.5 Lastobond Pro HT-N is a self-adhe
available in two widths; 36 and 45 it
4.6 Lastobond Pro HT-S is a self-adherii
underlayment; meets ASTM D1970.
4.7 EnviroShield is a self -adhering, w
underlayment; meets ASTM D1970.
4.8 Lastobond 195 is a self -adhering,
meets ASTM D1970.
ONNEMOJeM
g, woven polyethylene surfaced, SBS modified bitumen roof underlayment
; meets ASTM D1970.
woven polyethylene surfaced, high temperature, SBS modified bitumen roof
polyethylene surfaced, high temperature, SBS modified bitumen roof
reinforced, sand -surfaced, SBS modified bitumen roof underlayment;
4.9 Lastobond Eaves Protection Sheet is a self -adhering, glass -mat reinforced, sand -surfaced, SBS modified bitumen
roof underlayment; meets ASTM D1970.
4.10 Lastobond Eco is a self -adhering, gl
meets ASTM D1970.
4.11 Lastobond Smooth Seal HT is a sE
underlayment; meets ASTM D1970.
4.12 RESISTO LB1236 is a self -adhering, €
with a 36-inch sheet width; meets A:
4.13 PrimeSource Grip -Rite Eave & Va
modified bitumen roof underlaymen
4.14 RESISTO LB1244 is a self -adhering, €
with a 44-inch sheet width; meets A;
reinforced, sand -surfaced, SBS modified bitumen roof underlayment;
hering, glass -mat reinforced, film -surfaced, SBS modified bitumen roof
-mat reinforced, sand -surfaced, SBS modified bitumen roof underlayment,
D1970.
=y Protector is a self -adhering, glass -mat reinforced, sand -surfaced, SBS
with a 36-inch sheet width; meets ASTM D1970.
ss-mat reinforced, sand -surfaced, SBS modified bitumen roof underlayment,
M D1970.
4.15 Colphene FR GR is a self -adhering, fiberglass reinforced, granule -surfaced, SBS modified bitumen roof
underlayment; meets ASTM D1970 a d FRSA/TRI April 2012 (04-12).
5.1 This is a building code evaluation. Nether NEMO ETC, LLC nor Robert Nieminen, P.E. are, in any way, the Designer
of Record for any project on which th s Evaluation Report, or previous versions thereof, is/was used for permitting
or design guidance unless retained sp cifically for that purpose.
5.2 This Evaluation Report is not.for use in FBC HVHZ jurisdictions.
5.3 Fire Classification is not part of this report; refer to current Approved Roofing Materials Directory for fire ratings of
this product.
5.4 Soprema Roof Underlayments may The used with any prepared roof cover where the product is specifically
referenced within FBC approval doc ments. If not listed, a request may be made to the Authority Having
Jurisdiction for approval based on this valuation combined with supporting data for the prepared roof covering.
5.5 Allowable Roof Covers:
Wood or
Slate or
Undeelayment
sphalt
Nail -On
Foam -On
Metal.
Composite
Composite
S
ingles
Tile
Tile
Shakes&
Shingles
Slate
Lastobond TU HT
I
Yes,;
Yes
Yes
Yes
Yes
-Yes
„
fff
See'S.5 1
Lastobond Shield /Pro HT-N /
#Yes
No
No
No
Yes
Yes
RESISTO SA SMOOTH PLY 40
j
Lastobond Shield HT / Pro HT-S
Yes '=
No
No
Yes
EnviroShield
Yes
No;
No_
= Yes ."'
Yes
Yes
NEVIO ETC, LLC
Certificate of Authorization #32455
6' EDIT ON (2017) FBC NON-HVHZ EVALUATION
Soprema Roof Underlayments
Evaluation Report 518010.06.09-R12
F12569-1114
Revision 12:02/12/2018
Page 3 of 8
Wood or
Slate of
Underlayment
Asphalt
Nail -On
Foam -On
Metal
Composite
Composite
Shingles
Tile
Tile
Shakes &
Slate
Shingles
Lastobond Eaves Protection Sheet /
No
_ No
No . -•
Yes
Yes:'
Lastobond 195
Lastobond ECO / RESISTO LB1236,
Grip -Rite Eave &Valley Protector /
Yes
== No
No
No,
`Yes
Yes ,
RESISTO LB1244
=
Lastobond Smooth Seal HT
"Yes :
No
No _
= Yes
Yes
Yes_
Colphene FR GR
Yes :''
Yes
Yes
'. See 5.51
No
Yes
Yes
5.5.1 ".Foam -On Tile" is limited to use of
ng Approved tile adhesives / underlayment combinations.
Adhesive
lorlda Product Approval
Underlayments
DowTileBond`"
FL22525
Lastobond TU HT
ICP Adhesives Polyset" AH-160
FL6332
Lastobond TU HT or Colphene FR GR
5.6 Allowable Substrates:
5.6.1 Direct -Bond to Deck:
Lastobond Shield, Lastobond Pro
EnviroShield, Lastobond TU HT, I
LB1236, Grip -Rite Eave & Valley P
➢ Plywood; ASTM D41 primed p
Southern Yellow Pine; ASTM C
Colphene FR GR applied to:
➢ Plywood; ASTM D41 primed p
Note:
➢ While not required over plyA
with Elastocol Stick or Elastoo
➢ Soprema requires tongue-anc
the self -adhering underlaymei
5.6.2 Bond -to -Insulation:
Lastobond Shield, Lastobond Pro
EnviroShield, Lastobond TU HT,
LB1236, Grip -Rite Eave & Valley
applied to:
➢ Dens Deck Prime; SECUROCK 1
For installation under mechanical
requirements of the prepared roc
tile systems (Lastobond TU HT oT
and installed based on testing of
Testing Application Standard TAS
2 Refer to Tile Manufacturer's orAdhesive Ma
MEMO ETC, LLC
Certificate of Autharizatton ##32455 67"
-N, RESISTO SA SMOOTH PLY 40, Lastobond Shield HT, Lastobond Pro HT-S,
;tobond Eaves Protection Sheet, Lastobond 195, Lastobond ECO, RESISTO
Lector, RESISTO LB1244 or Lastobond Smooth Seal HT applied to:
vood; OSB; ASTM D41 primed OSB; Southern Yellow Pine; ASTM D41 primed
. primed structural concrete.
ASTM D41 primed structural concrete.
A, OSB or Southern Yellow Pine substrates, Soprema recommends priming
600c if the final roof cover is not slated for installation within 24 hours.
;roove board decking be covered with plywood or OSB prior to installation of
-N, RESISTO SA SMOOTH PLY 40, Lastobond Shield HT, Lastobond Pro HT-S,
tobond Eaves Protection Sheet, Lastobond 195, Lastobond ECO, RESISTO
otector, RESISTO LB1244, Lastobond Smooth Seal HT or Colphene FR GR
rpsum-Fiber Roof Board.
attached prepared roof coverings, insulation shall be attached per minimum
covering manufacturer's Product Approval. For installations under foam -on
r), insulation attachment shall be designed by a qualified design professional
e insulation/underlayment system in accordance with FM 4474, Appendix D,
14, Appendix or UL1807.
Florida Product ApprovalforOverturning Moment Resistance Performance.
Evaluation Report S18010.06.09-R12
ON (2017) FBC NON-HVHZ EVALUATION FL2569-R14
Soprema Roof Underlayments Revision 12: 02/12/2019
Page 4 of 8
5.6.3
5.6.4
#1
#2
a' MEMO6etC.
Lastobond Shield, Lastobond Pro HT-N, RESISTO SA SMOOTH PLY 40, Lastobond Shield HT, Lastobond Pro HT-S,
EnviroShield, Lastobond TU HT, Lastobond Eaves Protection Sheet, Lastobond 195, Lastobond ECO, RESISTO
LB1236, Grip -Rite Eave & Valle Protector, RESISTO LB1244, Lastobond Smooth Seal HT or Colphene FR GR
applied to:
➢ ASTM D226, Type I or II felt; opra-G; Modified Sopra-G.
For installations under mechanicAlly attached prepared roof coverings, base layer shall be attached per minimum
codified requirements. For instatrffl
tions under foam -on the systems (Lastobond TU HT only), base layer shall be
attached in accordance with FRS April 2012 (04-12).
address wind uplift resistance
underlayment forms part of the
that are not addressed in FRSA,
Design Pressure is the result of I
ultimate passing pressure divide
Refer to FRSA/TRI April 2012 (04
maximum ueslgn rressure=-45
Deck:
Min.15/32-ini
Jurisdiction.
Primer:
(Optional) Elas
Underlayment:
Lastobond TU
Maximum Design Pressure = -67.
Deck:
Structural cor
Jurisdiction.
Primer:
Elastocol600c
Underlayment:
Lastobond TU
t_Svstems in Foam -On Tile Applications: FRSA/TRI April 2012 (04-12) does not
of all underlayment systems beneath foam -on tile systems, where the
iad-path. The following wind uplift limitations apply to underlayment systems
PRI April 2012 (04-12) and are used in foam -on tile applications. Maximum
sting for wind load resistance based on allowable wind loads, and reflects the
by 2 (the 2 to 1 margin of safety per FBC 1504.9 has already been applied).
.2) or FBC 1609 for determination of design wind pressures.
plywood to meet project requirements to satisfaction of Authority Having
col Stick, Elastocol 600c or RESISTO EXTERIOR PRIMER
or Colphene FR GR, self -adhered.
to meet project requirements to satisfaction of Authority Having
or Colphene FR GR, self -adhered.
#3 Maximum Design Pressure=-150.0 sf:
Deck: Min. 15/32-in h APA-rated BCX plywood (may be installed C-side up) to meet project
requirements to satisfaction of Authority Having Jurisdiction.
Deck Preparation: Plywood shall ae thoroughly cleaned to remove dust and debris that may inhibit adhesion. All
sheathing fasteners shall be driven flush with the surface. All sharp splinters and wood
projections shall be removed/sanded.
Primer: (Optional) RESISTO EXTERIOR PRIMER
Underlayment: Lastobond TU HT, self -adhered, shall be thoroughly roll using hand roller and/or weighted
roller to ensure there are no voids, and ensure there are no voids/bridging at side and end -
laps.
#4 Maximum Design Pressure=-60
Deck: Min.19/32-in
Jurisdiction.
Base Sheet: Sopra-G or MI
1517.5.2) spas
in the center
Underlayment: Lastobond TU
5.6.4.1 All other direct -deck, adhered S
Design Pressure of-45 psf.
plywood to meet project requirements to satisfaction of Authority Having
lifted Sopra-G mechanically attached with nails (FBC 1517.5.1) and tin caps (FBC
d 6-inch o.c. at the 4-inch laps and 6-inch o.c. in three (3), equally spaced rows
the sheet.
T or Colphene FR GR, self -adhered
lrema underlayment systems beneath foam -on tile systems carry a Maximum
NEMO ETC, LLC Evaluation Report 518010.06.09-1112
Certificate of Authorization #32455 6M EDITION (2017) FBC NORM-HVHZ EVALUATION FL2569-R14
soprema Roof Underlayments Revision 12: 02/12/2018
Page 5 of 8
5.6.4.2
5.7
5.8
l
(4NEIVIO I etc.
For mechanically attached Base heet, the maximum design pressure for the selected assembly shall meet or
exceed that required under FRSA TRI April 2012 (04-12), Appendix A, Table 1A.
Alternatively, the maximum desi n pressure for the selected assembly shall meet or exceed the Zone 1 design
pressure determined in accords ce with FBC 1609. In this case, Zones 2 and 3 shall employ an attachment
density designed by a qualified design professional to resist the elevated pressure criteria. Commonly used
methods are ANSI/SPRI WD1, FIV Loss Prevention Data Sheet 1-29 and Roofing Application Standard RAS 117.
Assemblies marked with an aste isk* carry the limitations set forth in Section 2.2.10.1 of FM Loss Prevention
Data Sheet 1-29 (January 2016) for Zone 2/3 enhancements.
Exposure Limitations:
Lastobond Eaves Protection Sheet, Lastobond 195,Lastobond Eco, Lastobond Smooth Seal HT, RESISTO LB1236,
Grip -Rite Eave & Valley Protect r or RESISTO LB1244 shall not be left exposed for longer than 30-days after
installation.
Lastobond Shield, Lastobond Pro HT-N, RESISTO SA SMOOTH PLY 40, Lastobond Shield HT or Lastobond Pro HT-
S, EnviroShield shall not be left a posed for longer than 90-days after installation.
Lastobond TU HT or Colphene FR GR shall not be left exposed for longer than 180-days after installation.
When loading roof tiles on the uiderlayment in direct -deck tile assemblies, the maximum roof slope shall be as
follows. These slope limitations an only be exceeded by using battens during loading of the roof tiles.
t?WP' m
Maximum
Underlayment
Tile Profile
Staging Method
Slope
Flat
Max. 10-tile stack
6:12
Lugged
Max. 10-tile stack
5:12
Max. 10-tile stack (bottom 2-tile stack
shall be inverted, followed by 8 tiles high
6:12
on slope, as shown below)--
Lastobond TU HT
Lugged.:
...
4
Flat
Max. 10-tile stack
5:12
Colphene FR GR
Lugged
Max. 10-tile stack
6:12
NEMO ETC, LLC Evaluation Report S18010.06.09-1112
Certificate oJAat6orization #32455 6 EDITION' (2017) FBC NON-HVHZ EVALUATION FL2569-R14
Soprema Roof Underlayments Revision 12: 02/12/2018
Page 6 of 8
i
6.1
6.2
6.3
6.3.1
6.3.2
6.3.3
Soprema Roof Underlayments sh II be installed in accordance with Soprema published installation requirements
subject to the Limitations set forthl in Section 5 herein and the specifics noted below.
Re -fasten any loose decking pa
remove any dust and debris prii
RESISTO EXTERIOR PRIMER (ifap
Is, and check for protruding nail heads. Sweep the substrate thoroughly to
to application, and prime the substrate with Elastocol Stick, Elastocol 600c or
Lastobond TU HT, LastobondShi Id, Lastobond Pro HT-N,' RESISTO SA SMOOTH PLY 40, Lastobond Shield .HT,
Lastobond Pro HT'-S. EnviwShield Lastobond Eaves.. Protection Sheet, Lastobond 195, Lastobond Eco, Lastobond
Smooth Seal HT, RESISTO LB1236 Grip-Rite;Eave & Valley Protector, RESISTO.LB1244 or Colphene FIR GR-
Shall be installed in compliance With the requirements for ASTM D1970 underlayment in FBC Table 1507.1.1 for
the type of prepared roof coverin to be installed.
Non Tile Applications:
While priming. is optional, Soprerrja recommends priming with Elastocol Stick, Elastocol 600c or RESISTO EXTERIOR
PRIMER if the final roof cover is nQt slated for installation within 24 hours.
Apply sheet parallel to the roof �dge. Roll out approximately 10 ft of membrane and peel back the first 3 ft of
release film.
Adhere the exposed part to the substrate and unroll the remaining membrane as far as possible.
Once the entire length of membrane is in place, peel -off the release film diagonally while holding the membrane
tight. Firmly roll the membrane into place to achieve a bond.
Horizontal seams should be minimum 3-inches, configured to shed water. Vertical seams should be 6-inches and
staggered not less than; 2-ft froth vertical seams in the course below. All over -granule end -laps shall be sealed
using either heat -welding or hot ;ir welding techniques.
When installing at slopes above 8:12, Soprema recommends back -nailing in the overlap area at the top of the
sheet at 12-inch o.c.
For Valleys and Ridges: Cut and rlayment into 4 to 6 foot lengths. Peel the release paper and center sheet over
valley or ridge. Drape and press heet into place, working from the center of the valley or ridge in each direction.
For valleys, apply the sheet start! g at the lowest point and work upward.
Tile Applications Lastobond TU T or Co! hene FR GR only):
Reference is made to FRSA/TRI pril 2012 (04-12) Installation Manual and Table 1 herein, using the instructions
noted above as a guideline.
For foam -on the applications, r ference is made to Section 5.6.4 herein for wind resistance limitations that fall
outside the scope of FRSA/TRI A ril 2012 (04-12).
Tile shall be loaded and staged 1 a manner that prevents tile slippage and/or damage to the underlayment. See
Table 2 herein, and Soprema published requirements for tile staging.
As required by the B
this product.
MEMO ETC, LLC
Certificate of Authorization #32455
Offi l
or Authority Having Jurisdiction in order to properly evaluate the installation of
Evaluation Report 518010.06.09•1112
5 ' EDITION (2017) FBC NON-HVHZ EVALUATION FL2569-1114
Soprema Roof Underlayments Revision 12: 02/12/2018
Page 7 of 8
Contact the noted QA agency for
The following plants have qualified
ation on product locations covered for F.A.C. 61G20-3 QA requirements.
:ts under their respective physical properties specifications.
Plant
Specifica ion
Products)
Lastobond Shield, RESISTO SA SMOOTH PLY 40, Lastobond Shield HT,
Drummondville,
Lastobond Pro HT-N, Lastobond Pro HT-S, EnviroShield, Lastobond 195,
QC (Canada)
ASTM D1970
Lastobond Eaves Protection Sheet, Lastobond Eco, Lastobond Smooth
Seal HT, RESISTO LB1236, PrimeSource Grip -Rite Eave & Valley
Protector, RESISTO LB1244
ASTM D1970 04-12
Colphene FR GR
7/T-Rl
Lastobond 195, Lastobond Eaves Protection Sheet, Lastobond Eco,
Wadsworth, OH
ASTM D1970
Lastobond Smooth Seal HT, RESISTO LB1236, PrimeSource Grip -Rite
Eave & Valley Protector, RESISTO LB1244
ASTM D1970 & FRS, /TRI 04-12
LastobondTU HT; Colphene FR GR
Lastobond 195, Lastobond Eaves Protection Sheet, Lastobond Eco,
Gulfport, MS
ASTM D1970
Lastobond Smooth Seal HT, RESISTO LB1236, PrimeSource Grip -Rite
Eave & Valley Protector, RESISTO LB1244