HomeMy WebLinkAboutNOAC u RECEMD EXTERIOR RESEARCH & DESIGN, LLC. J U N 15 018 Certificate of Authorization #9503 \,JTRINI-ff IERD 353 CHRISTIAN STREET Si-. Lucie County, Permitting OXFORD, CT 06478 E�6 �Nu (203) 262-9245 VALUATION REPORT ICP Adhesives and Sealants, Inc. Evaluation Report 02768.02.06-116 12505 NW 44th Street ��� Q 'fP,ce0 FL6276-R6 Coral Springs, FL 33065 Date of Issuance: 03/21/2006 (888) 774-1419 Revision 6:10/12/2017 SCOPE: This Evaluation Report is issued under Rule 61G20-3 and the applicable rules and regulations governing the use of construction materials in the State of Florida. The docume tation submitted has been reviewed by Robert Nieminen, P.E. for use of the product under the Florida Building Cod . The products described herein have been evaluated for compliance with the 61h Edition (2017) Florida Building Coclle sections noted herein. DESCRIPTION: ICP Adhesives Polyset° RTA-1 LABELING: Labeling shall be in accordance with the requirements the Accredited Quality Assurance Agency noted herein. CONTINUED COMPLIANCE: This Evaluation Report is valid until such time as the named product(s) changes, the referenced Quality Assurance documentation changes, or provisions o the Code that relate to the product change. Acceptance of this Evaluation Report by the named client constitutes agreement to notify Robert Nieminen, P.E. if the product changes or the referenced Quality Assurance documentation changes. Trinity) ERD requires a complete review of this Evaluation Report relative to updated Code requirements . vith each Code Cycle. ADVERTISEMENT: The Evaluation Report number preceded by the words "Trinity I ERD Evaluated" may be displayed in advertising literature. If any portion of the Evaluation Report is displayed, then it shall be done in its entirety. INSPECTION: Upon request, a copy of this entire EvaluationJReport shall be provided to the user by the manufacturer or its distributors and shall be available for inspection at the job site at the request of the Building Official. This Evaluation Report consists of pages 1 through 8. Prepared by: Robert J.M. Nieminen, P.E. Florida Registration No. 59166, Florida DCA ANE1983 CERTIFICATION OF INDEPENDENCE: 1. Exterior Research & Design, LLC. d/b/a Trinity I ERD does not in any company manufacturing or distributing products it eval 2. Exterior Research & Design, LLC. d/b/a Trinity I ERD is n distributing products it evaluates. 3. Robert Nieminen, P.E. does not have nor will acquire, a finan which the evaluation reports are being issued. 4. Robert Nieminen, P.E. does not have, nor will acquire, a fina product. 5. This is a building code evaluation. Neither Trinityl ERD nor project on which this Evaluation Report, or previous versions specifically for that purpose. The facsimile seal appearing was authorized by Robert Nieminen, P.E. on 10/12/2017. This does not serve as an electronically signed document. nor does it intend to acquire or will it acquire, a financial interest of owned, operated or controlled by any company manufacturing or cial interest in any company manufacturing or distributing products for ncial interest in any other entity involved in the approval process of the Robert Nieminen, P.E. are, in any way, the Designer of Record for any thereof, is/was used for permitting or design guidance unless retained FILE Copy f \I I KINIlYIfRD � v ROOFING COMPONENT EVALUATION: 1. SCOPE: Product Category: Roofing Sub -Category: Roof Tile Adhesive Compliance Statement: ICP Adhesives Polyset® RTA-1, as produced by ICP Adhesives and Sealants, Inc., has demonstrated compliance with the 6th Edition (2017) Florida Building Code through testing in accordance with the Standards set forth herein. Compliance is subject to the Installation Requirements and Limitations / Conditions of Use set forth herein. 2. STANDARDS: Sections Property Standard Year 1504.2.1.1 Overturning resistance SSTD 11 1997 3. REFERENCES: Entity Examination Reference Date ERD (TST6049) Static Uplift —SSTD 11 E42730.08.13 08/23/2013 ERD (TST6049) Static Uplift —SSTD 11 ECM-SC6795.12.14-2 02/27/2015 Miami -Dade (CER 1592) HVHZ compliance • 16-0315.03 04/07/2016 PRI (TST5878) Static Uplift —SSTD 11 PFI-006-02-01 05/09/2005 PRI (TST5878) Static Uplift —SSTD 11 PFI-008-02-03 12/14/2005 PRI (TST5878) Static Uplift —SSTD 11 PFI-008-02-04 12/14/2005 PRI (TST5878) Static Uplift —SSTD 11 FOP-009-02-02 Rev1 03/24/2015 PRI (TST5878) Static Uplift —SSTD 11 FOP-009-02-01 Rev1 03/24/2015 PRI (TST5878) Static Uplift —SSTD 11 FOP-009-02-03 Rev1 03/25/2015 PRI (TST5878) Static Uplift —SSTD 11 FOP-009-02-04 Rev1 03/25/2015 PRI (TST5878) Static Uplift —SSTD 11 FOP-009-02-05 Rev2 06/01/2015 UL, LLC. (QUA9625) Quality Assurance Service Confirmation Exp. 06/05/2018 4. PRODUCT DESCRIPTION: 4.1 ICP Adhesives Polyset® RTA-1 is a single component polyurethane foam roof tile adhesive distributed in factory, pre -mixed canisters. S. LIMITATIONS: 5.1 This is a building code evaluation. Neither TrinityJERD nor Robert Nieminen, P.E. are, in any way, the Designer of Record for any project on which this Evaluation Report, or previous versions thereof, is/was used for permitting or design guidance unless retained specifically for that purpose. 5.2 This Evaluation Report is not for use in FBC HVHZ jurisdictions. 5.3 Fire classification is not part of this evaluation. Refer to a current Roofing Materials Directory for fire ratings of this product and FBC 1505.2. 5.4 ICP Adhesives Polyset® RTA-1 can be used with flat, low and high profile tiles or any rigid, discontinuous roof assembly having a current Florida Statewide Product Approval or approved on a local -level by the Authority Having Jurisdiction. 5.5 Minimum underlayment shall be per FRSA/TRI April 2012 (04-12) or having a current Florida Statewide Product Approval or approved on a local -level by the Authority Having Jurisdiction for use with ICP Adhesives Polyset® RTA-1. Exterior Research and Design, I.I.C. Evaluation Report 02768.02.06-R6 Certificate ofAuthori:ation #9503 6T" EDITION (2017) FBC NON-HVHZ EVALUATION FL6276-116 ICP Adhesives Polyset® RTA-1; (888) 774-2419 Revision 6: 10/12/2017 Page 2 of 8 5.6 Field tiles, meeting the limitations of FBC 16( projects having an Aerodynamic Uplift Moment 2A and 2B of FRSA/TRI April 2012 (04-12), not values. Refer to Section 10 and ICP Adhesiv( Adhesive Paddy Placement details. `J TRINITY I ERD 19.5.3, using ICP Adhesives Polyset® RTA-1 are limited to Ma), determined in accordance with FBC 1609.5.3 or Tables greater than the following Allowable Overturning Moment s and Sealants, Inc. published installation instructions for TABLE 1: FIELD TILES IN ICP­.-A DHESIVES POLYSET® RTA-1 ALLOWABLE OVERTURNING MI MENT PERFORMANCE DATA ` 4 To 1 MARGIN 0S' AF.TYALREADYAPPLIED Tile (FBC 1609.5.3) Adhesivo Paddy Placement Allowable Overturning Type Profile Placement Contact Area Moment (ft-lbf) Interdependent, Cross Bond Tile Application: On Underlayment: One (1) -5-inch long x -9 g am oblong shaped bead on underlayment at strengthening rib closest to I. nderlock side starting -4-inch below the the course line working up towards the ridge, ontinuing 1-inch above the tile course Tile Underside: 2 3r -', ISOnerete VF.latf ;` line and place the tile. 8 to 10 in Tile Head Lap: 51.8 y, ^ 1-inc the At'Tile Headlap: Continue on top of the exposed portion of underlayment- 10 in bead and onto the head of the lower course title and carry the adhesive bead minimum 4.5-inches horizontally across the h2ad of the lower course tile. See Section 10, Placement Detail #1. Interdependent, Cross Bond Tile Application: On Underlayment: One (1) -5-inch long x -9 gram oblong shaped bead on underlayment at strengthening rib closest to ttnderlock side starting -4-inch below the tile course line working up towards the ridge, continuing 1-inch above the tile course Tile Underside: 6 to 8 in 2 Concrete Medium line and place the tile. Tile Head Lap: 44.0 At Tile Headlap: Continue on top of the -1-in h exposed portion of the underlayment- 10 in bead and onto the head of the lower course t le and carry the adhesive bead minimum 4.5-inches horizontally across the h ad of the lower course tile. See Section 10, Placement Detail #2. Interdependent, Cross Bond Tile Application: On Underlayment: Two (2) -6-inch long x -12 gram oblong shaped beads on Concrete High underlayment, side -by -side, where the pan p rtion of the tile is to be located starting 36.2 -5-inch below the tile course line working up towards the ridge, continuing 1-inch Tile Underside: above the tile course line and place the tile. At Tile Headlap: Continue on top of the -1-inch exposed portion of the underlayment- 12 to 16 in' Tile Head Lap: beads and onto the head of the lower course ile and carry the adhesive bead 18 in' Clay High minimum 10-inches horizontally, or the entir width of the file, across the head of the 33.5 lower course tile. See Section 10, Placement Detail #3. Pan Tile to Underlayment: Two (2) ^7-inch long x -6 gram oblong shaped beads on underlayment, side -by -side, where the center of the pan tile contacts the deck starting ^2 to 3-inches from the eave end of the pan tile. Tile Underside: Cap Tile to Pan Tile: One (1) -7-inch long x-61gram oblong shaped bead at each long 35 to 40 in Clay Ca & Pan p (Barrel) edge of the cap tile, % to 1-inch from each edge, starting -2 to 3-inches from the eave Long Edge of 162.2 end working towards the ridge. Turn cap tile over and install onto pan, butting the Cap Tile: second course pan tile eave end on underlay ent, side -by -side, where the center of 20 to 25 in the pan tile contacts the deck starting "2 to inches from the eave end of the pan tile. See Section 10, Placement Detail #4. 5.6.1 Data in Table 1 relates to installation over a '3 2012 (04-12). Alternate underlayment systei Approval and/or approved on a local -level by Adhesives Polyset0'RTA-1. Exterior Research and Design, I.I.C. ' Certificate ofAutharization #9503 6TH EDITION (2017) FBC I ICP Adhesives Polyset® 0' underlayment system, as detailed in the FRSA/TRI April include those having a current Florida Statewide Product ! Authority Having Jurisdiction specifically for use with ICP Evaluation Report 02768.02.06-116 HZ EVALUATION FL6276-116 (888) 774-1419 Revision 6:10/12/2017 Page 3 of 8 F)o \I I KINITiIERD 5.6.2 Tile roof systems using tile types or profiles other than those listed above acquiring acceptance for use with ICP Adhesives Polyset® RTA-1 shall be tested in accordance with SSTD 11 or Testing Application Standard TAS 101. For the interdependent multi -paddy method, an additional 2-to-1 margin of safety above that specified in SSTD 11 or Testing Application Standard TAS 101 shall be applied in determining the 'allowable overturning moment'. 5.7 Hip and ridge tiles using ICP Adhesives Polyset® RTA-1 are limited to projects having hip/ridge design pressure requirements, determined in accordance with Table 1A of FRSA/TRI April 2012 (04-12), not greater than the following values. Refer to ICP Adhesives and Sealants, Inc. published installation instructions for Adhesive Paddy Placement details. TABLE 2. Hlf?.&RIDGE TILES IN„ICP ADHESIVES POLYSET®:RTA 1 °. k •ALLOWABLE U0LIFY1,kESIsTANCE,Pi2kFORPAAhCE DATA 2 TO 1 MARGIN'OFSAFEI YALREADYAPPLIED FOR INDEPENDENT PLACEMENT r IJ 4 T01 MARGIN4FSAFETYAIREADYAPPLIED FOR INTERDEPENDENT PLACEMENT Allowable Tile Substrate Attachment Method Design Pressure (psf) Clay or Interdependent: Head: One (1) #10 x 2%" screw; Concrete 2x PT ridge board Overlap: 1x6-inch x —10.5 gram 186.5 See Section 10, Placement Detail #5 r. Hip &Ridge Channel Metal (FB7 FL5374 Independent: Tile -to -metal, centered along tile: 3x6- �omerete *r r.�gwrp .galv�gnizeed only yy �; JJ inch x —30 gram, starting 3-inch from the tile head. 122.6 See Section 10, Placement Detail #6 Hip & Ridge Channel Metal (FBC FL5374): Independent: Tile -to -metal, centered along tile: 3x6- Clay galvanized only inch x ^30 gram, starting 4-inch from the tile head. 251.2 See Section 10, Placement Detail #6 Trim Lock (FBC FL5394): aluminum Interdependent: Clay or or On Trim -Lock'"' metal: One (1) ^7-inch long x —10 gram 93 Concrete Trim Lock'"" Plus (FBC FL5394): aluminum, oblong shaped paddy centered on metal. galvanized, Galvalume® or stainless steel At Tile Headlap: One (1) ^7-inch long x —10 gram oblong shaped bead at tile headlap. Clay or Trim Locklm (FBC FL5394): galvanized, Concrete Galvalume® or stainless steel See Section 10, Placement Detail W. 110 6. INSTALLATION: 6.1 ICP Adhesives Polyset® RTA-1 and the tile roof assembly shall be installed in accordance with FRSA/TRI April 2012 (04-12) and ICP Adhesives and Sealants, Inc. published installation instructions, subject to the limitations outlined in Section 5. 6.2 Hip and ridge boards or hip/ridge metal shall be installed in accordance with the FRSA/TRI April 2012 (04- 12). Proprietary hip and ridge metal shall be installed in accordance with the manufacturer's Florida Product Approval. 6.3 Installation shall be performed by applicators that hold a valid Qualified Applicator Card presented by ICP Adhesives and Sealants, Inc. 6.4 All tiles must be set in adhesive prior to tack free time (approximately 2 to 3 minutes). 7. BUILDING PERMIT REQUIREMENTS: As required by the Building Official or Authority Having Jurisdiction in order to properly evaluate the installation of this product. Exterior Research and Design, I.I.C. Evaluation Report 02768.02.06-116 Certificate of Authorization #9503 6EDITION (2017) FBC NON-HVHZ EVALUATION F1.6276-116 ICP Adhesives Polyset® RTA-1; (888) 774-1419 Revision 6: 10/12/2017 Page 4 of 8 H. MANUFACTURING PLANTS: Norton, OH 9. QUALITY ASSURANCE ENTITY: UL, LLC.—QUA9625; (847) 664-3623; LeAnna.Gr 10. PADDY PLACEMENT DETAILS (FROM ICP ADHESIVES AND 10.1 Detail #1: Flat Profile Tile: EaveooLrse Exterior Research and Design, I.I.C. Certificate of Authorization #9503 k INC. PUBLISHED LITERATURE): ,acted to paddy math fie start ovedock side `pac* at lie a xime line. Start Ltij Iiodca paddy amrowrmtely 1" abawe file e EDITION (2017) FBC �ON-HVHZ EVALUATION ICP Adhesives Polyset RTA-1; (888) 774-1419 \I TRINI7YJ ERD Evaluation Report 02768.02.06-116 FL6276-R6 Revision 6:10/12/2017 Page S of 8 TRINITY JERD 10.2 Detail #2: Low/Medium Profile Tile: 10.3 Detail #3: High Profile Tile: Exterior Research and Design, I.I.C. Evaluation Report 02768.02.06-116 Certiftate of Authorization #9503 6T" EDITION (2017) FBC NON-HVHZ EVALUATION FL6276-116 ICP Adhesives Polyset® RTA-1; (888) 774-1419 Revision 6:10/12/2017 Page 6 of 8 10.4 Detail #4: Two Piece Barrel (Cap & Pan) Tile: \ �+}l3 e�1 \I TRINITY ERD 10.5 Detail #5: Hip and Ridge (interdependent with screw): Adhere•starter• tile•withra? r'-x•7" Paddy,•placed-3"� downmcorri-hed& ofitile�j . Exterior Research and Design, U.C. Certificate of Authorization #9503 6' EDITION (2017) FBC P ICP Adhesives Polyset® 7,Fuc g 1"•)(;V'•8ead-of'ICP+ •Adliesiies, • P,.olyiset`RTA-lrrpof• ii1e•adhesiver•4 Code:Approy' .. -Fastener: Evaluation Report 02768.02.06-116 'HZ EVALUATION FL6276-116 (888) 774-1419 Revision 6:10/12/2017 Page 7 of 8 �l TRINITY I ERD 10.6 Detail #6: Hip and Ridge (independent placement): :_r 1 ,.�.' 3" x 6" Paddy 10.7 Detail #7: Hip and Ridi:e (interdependent placement): - END OF EVALUATION REPORT - Exterior Research and Design, I.I.C. Evaluation Report 02768.02.06-R6 Certificate ofAuthoriration #9503 6EDITION (2017) FBC NON-HVHZ EVALUATION FL6276-R6 ICP Adhesives Polyset® RTA-1; (888) 774-1419 Revision 6:10/12/2017 Page 8 of 8