HomeMy WebLinkAboutDESIGN PRESSURE CALCULATIONSSGANNEU By ENGINEERING & TESTING INC. Q —1 ^"twk/ RECEIVED Phone: (866) 781.-6889•Fas: (866) 784-8550 www.florid.aengineering,indtesting.com 250 S.W. 131h Avenue APR 2 0 2018 Pompano Beach, FL 33069 DATE: 4/17/18 sT. Lucie CLIENT: ADDRESS: 3921 S. PROJECT: ADDRESS: Residence 7e Drive Fort Pi #: 18-1506 FL 34982 I 2017 FBC/ASCE-7 DESIGN PRESSURE CALCULATIONS Proiect Information: Mean Roof Height = 20' Exposure: D Basic/Ultimate Wind Speed: Vi1t=170 mph Length = 25' Categol y: II Nominal Wind Speed: Vasd=V„lt*40.6 Width = 25' Slope. ! 6/12 (asd = allowable strength design) Parapet Wall: N/A Residential KZ = 1.08, Kzt = 1.0, Kd = 0.85 Note: The most conservative dimensions were utilized.f or the design calculations below. Design Calculations: Velocity Pressure: q = 0.00256*K,LKdV2 Velocity Pressure („ lt): q=0.00256Q.08)(1.0)(0.85)(170)2] = 67.92 psf Velocity Pressure (asd): q=0.00256(i .08)(1.0)(0.85)(170*�0.6)2] = 40.75 psf Width of Pressure Coefficient: 0.h(25') = 2.5' 0.4(20') = 8.0' } use: 3'0" Effective Wind Area: <10f 2 For hip roofs with a roof slope of 25 degrees or less, zone three (3) shall be treated as zone two (2). External Pressure Coefficient: Internal Pressure Coefficient: ! 1) GCP1 = -0.9 1) GCP; = 0.18 2) GCP2 = -1.7 3) GCP3 = -2.6 I v�Q v Qrcalitr�';;M�\�A�/.gssrcrance ` Page 2, 4/17/18, Job Order All Area Roofing FLO A Kline Residence - Sloped Tile Roof Deck! 2508 Harbour Cove Drive; Fort Pierce, FL: i N ) Design Pressures Based on Vasd: 1) Field Pt = 40.75 * [(-0.9) — (0.18)] = -44.0 psf 2) Perimeter P2 = 40.75*[(-1.7) — (0.18)] = -76.6 psf 3) Corners P3 = 40.75*[(-2.6) — (0.18)] = -113.3 psf Per Tile System: Moment Based Aerodynamic Multiplier: 0.205 ft3 Restoring moment due to gravity: Deck Application - Table 2 = 6.54 ft-lbf (Table 23 Attachment resistance expressed as a moment: Mf = 40.4 ft-lbf 3M 2-Component Foam Roof Tile Adhesive AH-160 Set (Table 6, Single Medium Paddy 24g) 1) Field : Mr, = ( 44.0*0.205) — 6.54 ft. lb = 2.5 ft. lb. < 40.4 ft. lb = PASS 2) Perimeter: Mr2 = ( 76.6*0.205) — 6.54 ft. lb = 9.2 ft. lb. < 40.4 ft. lb = PASS 3) Corners : Mr3 = (113.3*0.205) — 6.54 ft. lb = 16.7 ft. lb. < 40.4 ft. lb = PASS System is acceptable as approved with single medium paddy (24g) placement of the 3M 2-Component Foam Roof Tile Adhesive AH-160 based on the requirements of NOA # 16-0112.07. Notes: Corners and perimeter area dimension shall not be less than a = 3'0" Contractor to verify that the fastening patterns meet manufacturer's requirements for issuance of a warranty (as applicable). All work shall be in compliance with the local building code product control notice of acceptance and manufacturer specifications and Florida Building Code 2017 Edition. Wind load calculations based on ASCE-7, 2017 FBC, and information provided by client. Client is responsible for verifying existing/proposed conditions/decks as it pertains to the above provided product approval. I All work shall be inspected by our field engineer (or authorized representative) or a building department inspector to verify com iance with specifications.AN Sincerely, Mark A. Mesiano? STATE of Florida Engineerin'�� " • ` . Florida Reg. No. 48Y(22 Certificate of AuthorizaNR'�\��