Loading...
HomeMy WebLinkAboutPLOT PLAN WITH ROOF PLANP-01 PV WATTS DS-01 DATA SHEET DS-02 DATA SHEET DS-03 DATA SHEET DS-04 DATA SHEET DS-05 DATA SHEET -- --- —DS=06 - DATA SHEET PROJECT DESCRIPTION: 18 x 295 HANWHA Q.PEAK BLK-G4.1 295 (295W) MODULES ROOF MOUNTED SOLAR PHOTOVOLTAIC MODULES 4- SYSTEM SIZE: 5.31 kW DC STC ARRAY AREA #1: 323.64 SQ FT. y EQUIPMENT SUMMARY 18 HANWHA Q.PEAK BLK-G4.1 295 (295" MODULES 01 SOLAREDGE SE5000H-US INVERTER 18 SOLAREDGE POWER P320 OPTIMIZERS SHEET INDEX A-00 PLOT PLAN & VICINITY MAP A-01 SYMBOLS & SYSTEM DESCRIPTION S-01 ROOF PLAN & MODULES S-02 STRUCTURAL ATTACHMENT DETAILS E-01 ELECTRICAL LINE DIAGRAM E-02 WIRING CALCULATIONS E-03 SYSTEM LABELING /l I / - - o- -- / / GOVERNING CODES: FLORIDA ELECTRIC CODE, 6TH EDITION 2017 EDITION (FEC) FLORIDA RESIDENTIAL CODE, 6TH EDITION 2017 (FRC) FLORIDA PLUMBING CODE, 6TH EDITION 2017 (FPC) FLORIDA BUILDING CODE, 6TH EDITION 2017 EDITION (FBC) FLORIDA MECHANICAL CODE, 6TH EDITION 2017 (FMC) ARTICLE 690, NEC 2014 CODE BOOK ♦ sb j 1-STORY / HOUSE % 4� ♦ ST,LUCIE COUNTY ` PLAN REVIEW / / 55 -6" DATIE: `�iW ♦ Ei ` N DAIT:- `�� 110' B• DATE:r— N w s s owl P e Q�i mom / EXISTING DRIVEWAY / 30'-10" 1 PLOT PLAN WITH ROOF PLAN A-00 SCALE: 1/32" = V-0" (E) MAIN DISTRIBUTION PANEL ROOF #1 (18) HANWHA Q.PEAK BLK-G4.1 295 (295" MODULES 2 1HOUSEPHOTO A-00 PROJECT SITE — V H.Y , x I Q- G:' PROJECT SITES .; `SCALE: NTS 0 . A a r; Lakewood 1 ;-Park L . �s ,ay r' '' f{esSure Coast' ,, =At7pari and ' t . oslna,,S parR; 9_501,Poinciana.Cou& . i + s 11y• :. i t �' -FoilReic Nonh v 4 . i - �§„ �•.,L Anglevillas N' * ,I1 COPYRIGHTED BY CASTILLO 3 VICINITY MAP ENGINEERING SERVICES, LLC A-00 SCALE: NTS Engineering ``a DESIGNED TO PERMIT.' CASTILLO ENGINEERING SERVICES, LLC COA828345 2381 CREST RIDGE COURT SANFORD, FL32771 TEL'' 407.474.9181ERMOCRATES E CASTILLO- FL PE 52590 REVISIONS DESCRIPTION DATE REV PROJECT DEVELOPER APR 1„6 2018 0. 2 90 ST OF .XORIIV '•� �� N W ��% %`, U Z U M W ¢ LL � W VU Z a� J 0) 0 LL 2 SHEET NAME PLOT PLAN & VICINITY MAP SHEET SIZE ANSI B 11" X 17" SHEET NUMBER A-00 Castillo Enginring kw ee DESIGNED TO PERMIT. CASTILLO ENGINEERING SERCQA00E2MS LLC 2381 CREST RIDGE COURT SANFORD, FL 32771 TEL: 407-47"181ERMOCRATES E CASTILLO- FL PE 57590 Symbols: Sheet where Section .............. x section is located x-xx Detail ID Letter P—XSystem Elevation ...........Sheet where section is located Abbreviations: AC Alternating Current APPROX Approximate AWG American Wire Gauge — DescriptionREVISIONS DATE REV Detail ................ x Detail ID Letter x-xx Sheet where section is located Detail ID Letter Detail ................ x Area to be enlarged (Enlarged Plan) x sheet where section is located Keyed Notes.......... O Keyed note designation on applicable sheet Ground Terminal ..... � CB Combiner Box DC Direct Current DCD Direct Current Disconnect DISC Disconnect (E) Existing EL Elevation EQ Equal This system is a grid -tied, PV system, with PV generation consisting of 18 HANWHA Q.PEAK BLK-G4.1 295 (295" MODULES PV modules with a combined STC rated do output power of 5,310W. The modules are connected into 1 SOLAREDGE SE5000H-US INVERTER. The inverter has electronic maximum power point tracking to maximize energy captured b the PV modules. The inverter also has an internal round gY P Y g fault detection and interruption device that is set to disconnect the array in the event that a ground fault that exceeds one ampere should occur. The inverter has DC and AC disconnect integrated system and labels are provided as required by the Nationali���r,l� Electric Code rCRIPTION PROJECT DEVELOPER e,.� .CAST/� � �..• - - -- -- --- - ---- —JB—_---_ Junction Box R\t Modules • 5 0 ' Grounding Point/rod.... .,L Solar Panel ......... or 00 odulewithSource Circuit number Combiner Box .......... Cg MCB Main Combiner Box MFR Manufacturer MIN Minimum MISC Miscellaneous (N) New --- — _ — Junction Point of - Inverter Box Utility O Centralized AC to -♦ Connection DC Inverter utility Meter - - -- - - - - - A OF •'•:c P ��� as S'•''""�• N �` �, /p E - - PROJ �B► DC Disconnect .......... DCD Main Distribution MDP Panel """"""""""" Fuse ...................... —.�,— OvercurrentBreaker.. Inverter .................... - OCPD OverCurrent Protection Device POCC Point Of Common Coupling PV Photovoltaic SF Squarefoot/feet STC Standard Test Conditions TBD To Be Determined TYP Typical VIF verify In Field WP Weather Proof Figure 1: PV System Block Diagram When the sun is shining, power from the PV array is fed into the inverter, where it is converted from DC to AC. The inverter output is then used to contribute to the power requirements of the occupancy. If PV power meets the requirements of the p q p Y• p q loads of the occupancy, any remaining PV power is sold back to the utility. When utility power is available, but PV-power is not available, building loads are supplied by the utility. The inverter meets the requirements of IEEE 1547 and UL 1741. This means that if it detects a loss of utility power, it will automatically disconnect from the utility. When utility voltage is restored, the inverter automatically reconnects to the utility grid after verifying utility voltage and frequency stability. W V Z U � w ¢ M ¢ u C) w W U W Z W O W a- a LU b CD O _ Transformer ............. On a day with average Florida sunshine, this system outputs 20.8 kWh per day on site. SHEET NAME SYMBOLS & SYSTEM DESCRIPTION SHEET SIZE ANSI B X 17EE Automatic ............... j ATS ; Transfer Switch COPYRIGHTED BY CASTILLO ENGINEERING SERVICES, LLC SHHEET NUMBER SHEET A-Q 1 MODULE TYPE, DIMENSIONS & WEIGHT NUMBER OF MODULES =18 MODULES MODULE TYPE = HANWHA Q.PEAK BLK-G4.1 295 (295W) MODULES MODULE WEIGHT = 41.45 LBS / 18.8 KG. MODULE DIMENSIONS = 65.7"x 39.4" = 17.98 SF UNIT WEIGHT OF ARRAY = 2.31 PSF I. -- CALC'S (ROOF #1) ARRAY AREA = 323.64 SQ. FT. ROOF FACE AREA = 1030.68 SQ. FT. 323.64 / 1030.68 = 31.40% OF ROOF FACE AREA COVERED BY ARRAY DESCRIPTION (ROOF #1) ROOF TYPE - BARREL TILE ROOF ROOF TILT - 22.6° ROOF AZIMUTH -180° TRUSSES SIZE - 2"x4" @ 24" O.C. (18) HANWHA Q.PEAK BLK-G4.1 295 (295W) MODULES (N) (18) SOLAREDGE POWER P320 OPTIMIZERS (38) PV ATTACHMENT @ 48" O.C. MAX (N) UNIRAC STANDARD RAIL WIND ZONE 1 (TYP.) WIND ZONE 2 (TYP.) ROOF PLAN & MODULES SCALE: 3/32" = V-0" 631.011 COPYRIGHTED BY CASTILLO ENGINEERING SERVICES, LLC GENERAL INSTALLATION PLAN NOTES: 1) DRAWINGS SHOWN MAY NOT REFLECT FIELD CONDITIONS. CONTRACTOR TO FIELD VERIFY CONDITIONS PRIOR TO INSTALLATION. 2) CONTRACTOR MAY LOCATE PV MODULES TO DIFFERENT LOCATION THAN SHOWN, BUT SHALL NOT PLACE PV MODULES IN WIND ZONE &UNLESS NOTED OTHERWISE IN NOTE 3 BELOW. 3) ROOF ATTACHMENTS SHALL BE INSTALLED AS SHOWN IN SHEET S-02 AND AS FOLLOWS FOR EACH WIND ZONE: WIND ZONE 1: 4-0" O.C. WIND ZONE 2: 2'-0" O.C. WIND ZONE 3: NOT ALLOWED. SEE SHEET S-02 FOR SUPPORTING CALCULATIONS. 4) EXISTING RESIDENTIAL BUILDING IS ASSUMED TO BE BARREL TILE ROOF WITH MEAN ROOF HEIGHT LESS THAN 30 FT AND SYP 2X4 WOOD ROOF TRUSSES SPACED 24" O.C. EXISTING ROOF SLOPE FOR SOLAR SYSTEM RETROFIT IS ASSUMED TO BE BETWEEN 7 TO 27 DEGREES. CONTRACTOR TO FIELD VERIFY AND SHALL REPORT TO THE ENGINEER IF ANY DISCREPANCIES EXIST BETWEEN PLANS AND IN FIELD CONDITIONS. z (N) JUNCTION BOX (TYP.) ry U- 3/4" PVC CONDUIT RUN (E) UTILITY METER (E) MAIN DISTRIBUTION PANEL (N) AC DISCONNECT (N) PV METER (IF REQUIRED) (N) SOLAREDGE SE5000H-US INVERTER LEGEND e ; 39.411 v -o r �sB< ti Lo co HANWHA Q.PEAK BLK-G4.1 295 (295W) MODULES JB - JUNCTION BOX INv -INVERTER DC - INTEGRATED DC DISCONNECT sLD - SOLAR LOAD CENTER PM -PRODUCTION METER MDP - MAIN DISTRIBUTION PANEL O ❑ -VENT, ATTIC FAN (ROOF OBSTRUCTION) O - ROOF ATTACHMENT — — -RAFTERS - CONDUIT CB - COMBINER BOX Lngineerl.ng w, DESIGNED TO PERMIT-' CASTILLO ENGINEERING SERVICES, LLC COA C 28345 2381 CREST RIDGE COURT SANFORD, FL 32771 TEL' 407d/4-9181ERMOCRATES E CASTILLO - FL PE 5259D REVISIONS DESCRIPTION DATE REV PROJECT DEVELOPER APR 161016 .1111111112- 11/111111111�`,,` W 0 Lf) W V M Q Ii U) U W W KU C °- a —� G)O 0 LI_ SHEET NAME ROOF PLAN & MODULES SHEET SIZE ANSI B 11" X 17" SHEET NUMBER S-01 I COPYRIGHTED BY CASTILLO ENGINEERING SERVICES, LLC TILES AFFECTED WITH APPROVED ITEN TO TORQUE PER UF. INSTRUCTIONS ALUMINUM L-FOOT TYP SlQ END -CLAMP W/a" - 20 HEX CAP ST STL BOLT AND ST STL SERRATED FLANGE -NUT TYP. L°lo�D� b END -CLAMP SIZE VARIES. 15 EACH STANDOFF PCM OMOUNTATTACHEMENT APPLY A GENEROUS AMOUNT OF GEOCEL a" -16 HEX CAP ST STL BOLT i 3300 PREFESSIONAL GRADE AND ST STL SERRATED POLYURETHANE SEALANT OR FLANGE -NUT TYP. - APPROVED SIMILAR FOR WATER TIGHT SEAL AS REQUIRED ' PHOTOVOLTAIC -� = MODULE TYP. / C - _ FLAT OR BARREL PCM SOLAR J %� TILES TYP. _ SO RAIL TYP. _ (6) 1/4"X1-1/2" ST STL -- - - - - - WOOD SCREWS WOOD PCM OMOUNT - - - SHEATHING STAND OFF ASSY TYPICAL PV SOLAR RAIL END CONNECTION DETAIL SCALE: 1"=1'-0" PCM SD RAIL TYP PHOTOVOLTAIC MODULE TYP. ALUM L-FOOT TYP EACH STANDOFF e -16 HEX CAP ST STL BOLT AND ST STL SERRATED FLANGE-NUTTYP. PCM OMOUNT STANDOFF ASSY �, JC APPLY A GENEROUS AMOUNT OF / GEOCEL 3300 PREFESSIONAL GRADE POLYURETHANE SEALANT OR APPROVED SIMILAR FOR WATER TIGHT SEAL AS REQUIRED WOOD SHEATHING CENTER -CLAMP WITH a" - 20 HEX CAP ST STL BOLT AND (1) ST STL SERRATED FLANGE NUT TYP. FLAT OR BARREL ROOF (6) 1/4°X7-1/2" ST STL TILES TYP. WOOD SCREWS TYPICAL PV SOLAR RAIL MID CONNECTION DETAIL SCALE: 1" = 1'-0" ATTACHMENT DETAIL (ENLARGED VIEW) SCALE: 1" = 1'-0" TECHNICAL' '` � it A13 00 GRADE POLYURETHANE SEALANT t. PRODUCT NAME aratlo:Gw gaCe eautstercy 3300e RTfamard ' Grade PoWethaim SeraL=m Pflnw. Not regrmed an rrost 2 khUF� Gattisre Surfaces Paekag,,X; 10.1 it o c2dridi ABhsbress Uritd X' The sl,urrin•YAIDams Company Y lonc=o 7�torne. ('Gaxel Prad x:ls Gm45y • �' alartnuay, n gbbk and rachvrod an Cleveland, OH 44115 Phara(80�& -7615 AaPTeafwn SLy,dadc Meets Far 37g-70P7 ASTA1C920 T1PaS Grade Nta CLw 25. Use Nf, A M G, a"d 0; fleets A. —.4e.eUSAcorn a(l,'TT-S-ITYJOC, Palatal Sp 3. PRODUCT DESCRIPTION: '� c�:L CfassM1 Mrx�ts �aa��a..,,-. Prakzl 15—Elora •With toads e, _W.W. rardfiuo • MOMASTN C 820 •fktba • Mw'u,el cn,kd,age • I}knorp5y oYtzim m m¢! wla:es • CmU,k. roc TDI(to a dk--yamia L b"dat,-... • Do teat appy over Carry a cantamineted soBces ' Oa ret apply to at5sofpttYe surBces to eB•adichaz it—Itc Price bstirg fa dismiondian or Stzkimg 6asndg, skygidhii roolrp seams AdMrn Ta Masorvy, ceramics. wood. roe" Pra'eOUao. t m ,bat steel KYrur 500'. a:un m• a5plaft in Pants and rats shingles, bu2dng page. BUR, Corexere. Tel � foog'ass, and otheaommon Balding substraes d' 1 h° r,w..o.�.su.ae am,..mseaw'eew, u•wnsime"°cmaee"s.. '011+ Trecwm�in•sm.ame.m.algal..�sn..emmrerin'..nown.•o. core . such ea s eta sealant Kyra � a a ,ry�eel,m6.myX d rvkaa trc. adhrsiaT sMt1a be teged m ®tlI Uitluad Sa,bstrme prig ti phlli{ing. b VAPOR/PARfICULATERESPIRATOR lallue, and az lour site rangy. tee test ton, apply sealant head MAY BE EFFECTIVE. Folo, direefore for resphata,se. Weer me rophatorfa vdl eIIlher replace the proluct a1 no ard Slow oneend oorlhe to— ed p egsW. Then the "teals t6ne until a1 vapors are 0 . Cost a refund the nr4nal purd prcela tlmt podio,dgodua U,al st1e0gm' tlYou nave an aaalhsg probktts during use, LEAVE THE talc to Perfamin accordance with Joid""C*` g: Joint depN should nit AREA and of freshaclt pprrooblemslafminaimp en Utis liratedtvanarty. tabu a asB exceed 5/8'. An opal ce062ckerrod later. IMIA[IIWTELYcan. doctor. If rel essodatedwlihubo•arenct shodd!»used to eanba loiht tleplh. avat�!e gatemagervy rfredkal kx,udcd.THIS LIMITED In stmlbw Ian's. a horhd treaker tape should bar insBled to oeatmod. Hare the label vidh you. Ad=te WARRANTY IS IN UEU OF ALL OTHER pmvad m,aapD'nt contact Yaagatlal Tavluirad when ear,dkg a abrodng thedrimifA,.11 WARRANTIES EXPRESS OR IMPLIED, INCLUDNO LWiga8cfc88195 adeQa ._e W rftian pond be Provided t4ERCHAMABILITY H HARE Tack Ffw..3 hours ; � a pVoved pankWatapbata ALL DISCLAIMED AND/0.9 . Ctae;1 day pphoved). Fellow respirator mendacte""s 7 actions for respbatdr UNITED IN DU ON TO THE EXTENT PERMITTED BYLAW WE tiewco lamp rah ro: -21PF to 150'F(-2D'Cto 66'L7 use. IRRIATES SIGN AND EYES. Avoid ContecttWheyosandskin. Incasud SHALL NOT BE LIABLE FOR INDIRECT.SPECIAL INCIDFMAL AppBcatbn Ttm+pmnhau �epntad, 0hah invrxdlatay vnlh OR CONSEDUENTIAL DAMAGES -20'Fto150•F(-29"Cto66' Q Application end T°ollnT. AAPty M14 Plentydvraofor l5 frinutp andcaladocto-Irnot evagaHe got IUxLUDWG LO57PROFRS57 FROMANVCfdISEWHATSOEVFR tonvenDonalpWNing equyment FRB Mir, frorn the back to 9..y ri,ed�IhEetrnalt. In cased silo anlaci vrasn NapgMry vim seep ANDSUCHDAIAAGESARE EXPRESSLY EXCLUDED. Some pre-d"ids and air packets. N Ptcatrah lempeaaae is helorP40' F (5' C), ad "*Stec Clothes enru num, b a s� shoes be rennand aId Immae e= slates do net allow me exci soon a Ikntation d IncidemN a pleaadklnsslhould tataken io stooge the subauel s are carrgYetely W and Keep container dosed wha, not lo Ise. Reacts wtlh valet h cksetl eanlamer to rat damages a bent long an rm ,ad vruranty Bst . co the Imd hae.lmmodmld tte �' °° °P lice, Ladirlglsreaxnrtm to ensure firm. prad� pressure which nay"use conra'ns m �. Do not tar>sfer above fimitaBn a exeLslon may -1-PPIY to you, This fmited fu0 contact with the rat sides eantu,s to e0,a acontaners la scot age. ty gives Yraron you specific legal Claming: R—. 3300 Scalain Imm Fuss Aid: In case deye canted. 0uah eeqM' nth cage enramte of orator. rghts,aidyou my a;= trm other nnhts wlieh vary from dale to gun aW toes before It cores. This be done by sanpag and rse of "'� Get modxal aner,gan If inlBtlon state. SoweriSsuahaz Xyld. RED. mamdaaaer's ins7lono s for safe PesNCs. dswdbwed, call Pagan CAantrd Crnter,h enhnyerry 7. MAINTENANCE use. Cured mataials may be m Wed mom, a Plrysiciancsr,uneiatYY1 DELAYED EFFECTS FROtA L0.`IG If sealant is danagcd and the bond s Inre by 11 web sharp teal. a S°"dPg. TERM OVEREXPOSURE. Abrading a M out ale t�raged area d nrau0c No s M e0eae Ste' end Matte: Unopenetl sand�,g of the dry Ibr, may mlease aysiatino s5^a "fish has Deep ahem the bond has Dcpynr rerco a the soalanL dean and should prdeaed Dan near. moisture. and dined gun. Do nit tommolo,gdumeqeaMpnc urea, long tens expcsura. p!ePon the(otnti.—Clance with the Instructions under open containers unto a➢ pnXwiotoy Iw beg, Wanhi_W TNs ending eardaU,s 'Sieface, Preparation.' ad reca ik. wed comMe[ed. tlalerloluipn Var, ehemip6 lmown to Ina state 0, Cdfamla to Cause carcaaM bitn 8. TECHTE� total When stared at 775 F (25' C). tlafocts or othu reproductive mum 00 s ACES: Carbons: CONTAINS NOT TAKE INTEpLY. K ''OUT OF reAr�nbdrvea throughpm ma US ALIPHATIC POLYISOCYANATE HEXAMCIPLENE DnSOCYANATE. Tfr PEACH OF CKUFEt3 araavaiWHaroprovMeteclorral ass5tance. Genoa l'mduda AROMATIC POLVISOCVANATE Graup's bh-thouca teamlrai uaff POLYMMiff-ENEPCLYPHENYL B. AVAMNIL.RY AND LOSE and laboratory facilities are LSOCYANATE k1ETHYLENEDFtPcNYL Available from rarios Imnber ydrJs, eaapped to mspond to pCdSc CRYSTALLINE CRYSTAE SILICA VAPOR HARMFUL MF off ha,mbi hardware stores, bare dmtera, censtnuti.. material and krdamal requests folhd inlormatlon and/brappbartitostestng. vapor of sahentsand-may tes DO NOT USE IF YOU [LAVE CHRONIC dsbibulos. Cost a,d further (LONG-TERkq WNG ORBREATHING PROBLEMS, OR IF YOU HAVE EVER tachr �� are.ndbtllo from you, k>ral ceoaa Proaaescroap 0110SIT"A con Nemfsm. �nwy. HAD A REACTION TO ISOCYAHATES. representaby—ftanaoaffice. joint i.Uk Fee hl ' X V r 24.1 USE 04LYWITH ADEQUATE VENTILATION, A POSITIVE PFESEURE 0- LIMITED WARRAYTY: V4' i8L 1,rT 1d4 AIR SUPPLIED RESPLRATOR Wrosll tlw1,er applied aecefduh9 to local x3'8• appto stfOULD BE WORN 70 dooellors this produce tau to 12-x1R' &a pi AN RE.IF UNAVAILABLE. AN A peHerm in aocadanee Mth a 3M'x Ira• 4.0 PP ROVED Re PROPERLY FITTED APPROVED NIOSN pe.M6sw alarmure, upon satisfactory oyvklercnd product Fa'adaltiorwlP'oducrA+fammtm'L as,br Utne aaexret h;,aea»rr loch -'slot" .GmaeWSA c9nx �V.O rwlnw1.up,1a 59'-r__ Sh�' w'�vx.�Om¢M1RM��Om�alaieOJ 130 150 130 3.bU b i Am" - ns.° ISO 140 �a _ m 160 Rates: 150 .. 1. Valises are thilai a design 3•secohtd Cast � 170 wind speeds In miles per hour (L✓s) at 33 ._._-._ ._;T J ft (10,) above ground for Esposwe t cat- rLm + egory. 2.: Linear Interpolation botween contours ---, (— ,IkvkM, j 160 Is permitted. 3. Islands and coastal areas outside the _Poor lost contour shall use the last wind speed 170 centOor of the coastal area. -� 4. Mountainous terrain, gorges, ocean Promontories, and special wind rcpms oft 160 shall be examined for unusual wind cord!- 180\ S. idnd speeds correspond to approximately ri a a 7% Probability of exceedance in 50 years (Annual ticteedance Probability=.O.E0143, MRI c 700 years). O Pr O FIGURE 1S09A(1) )R RISK-CA'.E16flRY-11_HUI VINGS AND OTHER STRUCTURES Wind'Speed Ult(rilph) Z60 Risk Category II Wind'Speed ASD (mph) mom Exposure Category 0 Mean Roof Height (ft) 111111101111111 Roof Slope (degrees) 111111IM1111111 Module Area (sq ft) 111111101111111 1Kzt 1 - Height Adjustment Factor, A 1 Roof Zone Pnet (30) 1 16 -27 2 16 -44.6 3 16 -67 P_net=K,1K�_zt P_(net,(30))' Roof Zone Pnet 1 16 -2r7 2 16 3. 16 67 cul 22.6. Maximum Uplift per *fastener'Wind Zone 1 297 0' PerPCMTest.report 352 * Roof atta6hements,at4' O/C w 2 rails Maximum Upliftper Wind Zone 2 245.3. —*fastener Per PCM Test report 352 *Roof attachements at 2' O/C w 2 rails Maximum Uplift per *fastener Wind Zone 3 368.5 Per PCM Test report 352 Engineering t°n' DESIGNED TO PERMIT" CASTILLO ENGINEERING SERVICES, LLC COAS28W 2381 CREST RIDGE COURT SANFORD,FL32771 TEL' 407-474-918JERMOCRATES E. CASTILLO - FL PE M90 REVISIONS DESCRIPTION DATE REV PROJECT DEVELOPER APR vo�toi a �tit�o CASTj��°1°°°� u �1 0 590 S ATE OF :� S/O N A PROJECT W U LO Z U M W QLL � U W W z0 IZ ` U') W J 0)O O LL 2 SHEET NAME STRUCTURAL ATTACHMENT DETAILS SHEET SIZE ANSI B 11" X 17" SHEET NUMBER S-D2 *Not allowed (2) #10 AWG USE-2/PV WIRE + Red (2) #10 AWG USE-2/PV WIRE -Black EGC #10 THWN-2 IN 3/4" PVC CONDUIT RUN JUNCTION BOX 600 V, NEMA 3 ULLISTED ---- ------------ ----- (N) INVERTER: #1 SE 5000H-US OUTPUT: 240 VAC, 21A 99% CEC WEIGHTED EFFICIENCY NEMA 3R, UL LISTED, INTERNAL GFDI WITH INTEGRATED DC DISCONNECT �mmmmw_= I I I I I I I I I I L--- -- — I I I I I I I --------- ----- --- (2) #10 AWG THWN-2 + Red (2) #10 AWG THWN-2 - Black EGC #8 THWN-2 USE METAL RACEWAYS FOR ANY DC CIRCUITS ENTERING BUILDING PRIOR TO INVERTER DC DISCONNECTING MEANS PER 690.31 J ELECTRICAL LINE DIAGRAM E-W SCALE: NTS SOLAR ARRAY (5.31 KW -DC STC) TOTAL :I ---- ---- ---- 18 HANWHA Q.PEAK BLK-G4.1 295 (295W) MODULES (1) STRING OF 10 MODULES CONNECTED TO MPPT #1 (1) STRING OF 08 MODULES CONNECTED TO MPPT #2 NOTE: 1. SUBJECT PV SYSTEMS HAS BEEN DESIGNED TO MEET THE - --- ---- ---- REQUIREMENTS OF THE NEC 2014, AND THOSE SET FORTH BY THE FLORIDA SOLAR ENERGY CENTER CERTIFICATION, INCLUDING MAXIMUM NUMBER OF MODULE STRINGS, MAXIMUM NUMBER OF P320 OPTIMIZERS MODULES PER STRING, MAXIMUM OUTPUT, MODULE MANUFACTURER AND MODEL NUMBER, INVERTER MANUFACTURER PV MODULE AND MODEL NUMBER, AS APPLICABLE. 2. RAPID SHUT DOWN BOX IS A COMBINER BOX WITH GROUND FAULT PROTECTION AS PER NEC 690.5, ARC FAULT PROTECTION AS PER NEC 690.11, RAPID SHUT DOWN PROTECTION AS PER NEC 690.12, AND MANUAL DISCONNECT AS PER NEC - 690.17. INTERCONNECTION 120% RULE - NEC 705.12(D)(2)(3)(b) UTILITY FEED + SOLAR BACKFEED 200.0 A + 30A = 230A BUSS RATING x 120% 200.0 A x 120OW 240A TO UTILITY GRID (N) PV METER (SMUD/GRIDLEY ONLY) (IF REQUIRED) (N) AC DISCONNECT: 240V, 60AMP, NON -FUSED NEMA 3R, UL LISTED (IF REQUIRED) (3) #10 AWG THWN-2 (1) #8 AWG THWN-2 GND IN 3/4" PVC CONDUIT RUN PROVIDE GROUNDING ELECTRODE CONDUCTOR FROM THE INVERTER TO AN EXISTING SERVICE GROUNDING ELECTRODE PER 690.47(B) - -I L2 I L1 I L2 30A/2P I L1 I L2 ' N L1 L2 N BI-DIRECTIONAL UTILITY METER a, 1-PHASE, 240V (E) MAIN DISTRIBUTION PANEL, 200A RATED, 240V. (E) MAIN LUG ONLY BREAKER 240V, 200A/2P EXISTING GROUNDING ELECTRODE SYSTEM COPYRIGHTED BY CASTILLO ENGINEERING SERVICES, LLC Engineering l�r� DESIGNED TO PERMIT- CASTILLO ENGINEERING SERVICES, LLC c°As2&US 2381 CREST RIDGE COURT SANFORD, FL 32771 TEL 40747"181ERMOCRATES E. CASTILLO- FL PE S2580 REVISIONS DESCRIPTION DATE REV PROJECT DEVELOPER APR 16 2018 %% ♦ � ''psi � ..� S ' -- -52 9.0—•-,— TE OF •��; ' E T LA � ♦♦ soil is aal►.°°°° W U u') W U M 0 J LL Z L U I.LI LLI Z U a.0 a Lu L0Ix -� rn O O LL SHEET NAME ELECTRICAL LINE DIAGRAM SHEET SIZE ANSI B 11"X 17" SHEET NUMBER E-01 - IDC CONDUCTOR AMPACITY CALCULATIONS: Castillo ARRAY TO JUNCTION BOX (INV #1): AC CONDUCTOR AMPACITY CALCULATIONS Engineering EXPECTED WIRE TEMP (In Celsius) 337 TEMP. CORRECTION PER TABLE (310.16) 0.94 NO. OF CURRENT CARRYING CONDUCTORS 4 CONDUIT FILL CORRECTION PER NEC 310.15(B)(2)(a) 0.80 CIRCUIT CONDUCTOR SIZE 10 AWG CIRCUIT CONDUCTOR AMPACITY 35A REQUIRED CIRCUIT CONDUCTOR AMPAC17Y PER NEC 690.8(A&B) 1.25 X 1.25 X Isc 15.16A DERATED AMPACITY OF CIRCUIT CONDUCTOR PER NEC TABLE 310.16 TEMP. CORRECTION PER TABLE (310.16) X 26.32A CONDUIT FILL CORRECTION PER NEC 310.15(B)(2)(a) X CIRCUIT CONDUCTOR AMPACITY Result should be greater than (15.16A) otherwise less the entry for circuit conductor size and ampacity DC CONDUCTOR AMPACITY CALCULATIONS: FROM JUNCTION BOX TO INVERTER (INV #1) -AMBIENT TEMPERATURE ADJUSTMENT _FOR EXPOSED CONDUIT PER NEC 310.15(B)(2)(c) - - - - - - +� - - - - EXPECTED WIRE TEMP (In Celsius) 33'+2Z = 55° TEMP. CORRECTION PER TABLE (310.16) 0.67 NO. OF CURRENT CARRYING CONDUCTORS 4 CONDUIT FILL CORRECTION PER NEC 310.15(B)(2)(a) 0.80 CIRCUIT CONDUCTOR SIZE 10 AWG CIRCUIT CONDUCTOR AMPACITY 35A REQUIRED CIRCUIT CONDUCTOR AMPACITY PER NEC 690.8(A&B) 1.25 X 1.25 X Isc 15.16A DERATED AMPACITY OF CIRCUIT CONDUCTOR PER NEC TABLE 310.16 TEMP. CORRECTION PER TABLE (310.16) X 18.76A CONDUIT FILL CORRECTION PER NEC 310.15(B)(2)(a) X CIRCUIT CONDUCTOR AMPACITY Result should be greater than (15.16A) otherwise less the entry for circuit conductor size and ampacity No. OF INVERTER 1 EXPECTED WIRE TEMP (In Celsius) 33' TEMP. CORRECTION PER TABLE (310.16) 0.94 NO. OF CURRENT CARRYING CONDUCTORS 3 CONDUIT FILL CORRECTION PER NEC 310.15(B)(2)(a) 1 91 CIRCUIT CONDUCTOR SIZE 10 AWG CIRCUIT CONDUCTOR AMPACITY 35A INVERTER OUTPUT CONDUCTORS REQUIRED CIRCUIT CONDUCTOR AMPACITY PER NEC 690.8(B) 1.25 X MAX INVERTER OUTPUT CURRENT 26.25A DERATED AMPACITY OF CIRCUIT CONDUCTOR PER NEC TABLE 310.16 TEMP. CORRECTION PER TABLE (310.16) X 32.9A CONDUIT FILL CORRECTION PER NEC 310.15(B)(2)(a) X CIRCUIT CONDUCTOR AMPACITY Result should be greater than (26.25A) otherwise less the entry for circuit conductor size and ampacity DC PHOTOVOLTAIC POWER SOURCE TO BE INSTALLED AT INVERTER #1 PER NEC 690.53 & 690.54 OPERATING CURRENT 13.97A OPERATING VOLTAGE 380V SHORT CIRCUIT CURRENT 15A MAXIMUM SYSTEM VOLTAGE 480V SOLAR MODULE SPECIFICATIONS MANUFACTURER HANWHA MODEL # Q.PEAK BLK-G4.1 295 PMAX 295W VMP 32.19V IMP 9.17A VOC 39.48V ISC 9.70A MODULE DIMENSION 65.7"L x 39.4"W x 1.26"D (In Inch) INVERTER #1 SPECIFICATIONS MANUFACTURER SOLAREDGE INVERTER MODEL # SE 5000A-US NOMINAL AC POWER 5.0 KW NOMINAL OUTPUT VOLTAGE 240V NOMINAL OUTPUT CURRENT - - - --21A--- DESIGNED TO PERMM' CASTILLO ENGINEERING SERVICES, LLC COA02SMS 2381 CREST RIDGE COURT SANFORD, FL 32771 TEL 4074749181ERNIOCRATES E CASTILLO -FL PE 52590 REVISIONS DESCRIPTION DATE REV PROJECT DEVELOPER y® EN1 1 1) &V o® %611 S1111 11f Qns th N 525 0 e S E OF PERCENT OF VALUES NUMBER OF CURRENT CARRYING CONDUCTORS IN EMT A` 1 ��S '•.. ,_ C? % • • • 0.80 4-6 PR 11e�eeeei�°� a 0.70 7-9 0.50 10-20 ELECTRICAL NOTES 1.) ALL EQUIPMENT TO BE LISTED BY UL OR OTHER NRTL, AND LABELED FOR ITS APPLICATION. AMBIENT TEMPERATURE SPECS RECORD LOW TEMP 0• AMBIENT TEMP (HIGH TEMP 2%) 33° CONDUIT HEIGHT 0.5" ROOF TOP TEMP 55• CONDUCTOR TEMPERATURE RATE 92• MODULE TEMPERATURE COEFFICIENT OF Voc -0.280/DPC W U r0) W U M QLL LLI U W W ZU rn aLLI W 2.) ALL CONDUCTORS SHALL BE COPPER, RATED FOR 600 V AND 90 p (- DEGREE C WET ENVIRONMENT. J 3.) WIRING, CONDUIT, AND RACEWAYS MOUNTED ON ROOFTOPS SHALL O O BE ROUTED DIRECTLY TO, AND LOCATED AS CLOSE AS POSSIBLE TO I ERMOCRATES CASTILLO PE# 52590 AN ENGINEER = THE NEAREST RIDGE, HIP, OR VALLEY. 4.) WORKING CLEARANCES AROUND ALL NEW AND EXISTING LICENSED PURSUANT TO CHAPTER 471, CERTIFY ELECTRICAL EQUIPMENT SHALL COMPLY WITH NEC 110.26. THAT THE PV ELECTRICAL SYSTEM AND 5.) DRAWINGS INDICATE THE GENERAL ARRANGEMENT OF SYSTEMS. ELECTRICAL COMPONENTS ARE DESIGNED AND APPROVED USING THE STANDARDS CONTAINED IN SHEET NAME CONTRACTOR SHALL FURNISH ALL NECESSARY OUTLETS, SUPPORTS, FITTINGS AND ACESSORIES TO FULFILL APPLICABLE THE MOST RECENT VERSION OF THE FLORIDA WIRING CODES AND STANDARDS. BUILDING CODE. FBC 107. CALCULATIONS 6.) JUNCTION BOXES PANEL BOARDS, RACEWAYS, AND CONDUITS ARE SIZED IN COMPLIANCE WITH NEC 408. 7.) ALL WIRE TERMINATIONS SHALL BE APPROPRIATELY LABELED AND SHEET SIZE READILY VISIBLE. ANSI B 8.) MODULE GROUNDING CLIPS TO BE INSTALLED BETWEEN MODULE FRAME AND MODULE SUPPORT RAIL, PER THE GROUNDING CLIP 11 " X 17" 9.) MODULE SUPPORTIRAIL TO BE BONDED TO CONTINUOUS COPPER COPYRIGHTED BY CASTILLO SHEET NUMBER G.E.C. VIA WEEB LUG OR ILSCO GBL-4DBT LAY -IN LUG. ENGINEERING SERVICES, LLC E-02 ELECTRIC SHOCK HAZARD THE DC CONDUCTORS OF THIS PHOTOVOLTAIC SYSTEM ARE UNGROUNDED AND MAY BE ENERGIZED LABEL LOCATION: DC DISCONNECT, INVERTER (PER CODE: NEC 690.35(F)) [To be used when inverter is ungrounded] ELECTRIC SHOCK HAZARD DO NOT TOUCH TERMINALS TERMINALS ON BOTH LINE AND LOAD SIDES MAY BE ENERGIZED IN THE OPEN POSITION DC VOLTAGE IS ALWAYS PRESENT WHEN SOLAR MODULES ARE EXPOSED TO SUNLIGHT LABEL LOCATION: AC DISCONNECT, POINT OF INTERCONNECTION (PER CODE: NEC 690.17(E)) ELECTRIC SHOCK HAZARD DO NOT TOUCH TERMINALS TERMINALS ON BOTH LINE AND LOAD SIDES MAY BE ENERGIZED IN THE OPEN POSITION LABEL LOCATION: AC DISCONNECT, POINT OF INTERCONNECTION PER CODE: NEC 690.17(E), CB LABEL LOCATION: AC DISCONNECT, POINT OF INTERCONNECTION (PER CODE: NEC690.54) LABEL LOCATION: POINT OF INTERCONNECTION (PER CODE: NEC 705.12(D)(7)) [Not required if panelboard is rated not less than sum of ampere ratings of all overcunent devices supplying it] LABEL LOCATION: AC DISCONNECT, DC DISCONNECT, POINT OF INTERCONNECTION (PER CODE: NEC690.56(C)) LABEL LOCATION: MARKINGS PLACED ON ALL INTERIOR AND EXTERIOR DC CONDUIT, RACEWAYS, ENCLOSURES, AND CABLE ASSEMBLIES AT LEAST EVERY 10 FT, AT TURNS AND ABOVE/BELOW PENETRATIONS AND ALL COMBINERMUCTION BOXES. (PER CODE: IFC605.11.1.4) LABEL LOCATION: INVERTER, JUNCTION BOXES (ROOF), AC DISCONNECT (PER CODE: NEC690.13.G.3 & NEC 690.13.G.4) LABEL LOCATION: CONDUIT, COMBINER BOX (PER CODE: NEC690.31(G)(3)(4) & NEC 690.13(G)(4) LABEL LOCATION: POINT OF INTERCONNECTION (PER CODE: NEC 705.12(D)(4)) LABEL LOCATION: POINT OF INTERCONNECTION (PER CODE: NEC690.15, 690.13(B)) ADHESIVE FASTENED SIGNS: • THE LABEL SHALL BE SUITABLE FOR THE ENVIRONMENT WHERE IT IS INSTALLED. • WHERE REQUIRED ELSEWHERE IN THIS CODE, ALL FIELD APPLIED LABELS, WARNINGS, AND MARKINGS SHOULD COMPLY WITH ANSI Z535A [NEC 110.21(B) FIELD MARKING]. • ADHESIVE FASTENED SIGNS MAY BE ACCEPTABLE IF PROPERLY ADHERED. VINYL SIGNS SHALL BE WEATHER RESISTANT [IFC 605.11.1.3] LABEL LOCATION: DISCONNECT, POINT OF INTERCONNECTION (PER CODE: NEC690.13(B)) INVERTER #1 LABEL LOCATION: DC DISCONNECT, INVERTER (PER CODE: NEC690.53) Label for solar disconnect label size 4" x 2" CAUTION: POWER TO THIS BUILDING IS ALSO SUPPLIED FROM THE FOLLOWING SOURCES WITH DISCONNECTS LOCATED AS SHOWN AT:® METER AND MAIN DISTRIBUTION PANEL AC DISCONNECT PV METER INVERTERS MARKING CONTENT AND FORMAT • RED BACKGROUND • WHITE LETTERING • MINIMUM 3/8" LETTER HEIGHT • ALL CAPITAL LETTERS • ARIAL OR SIMILAR FONT, NON -BOLD • REFLECTIVE WEATHER RESISTANT MATERIAL SUITABLE FOR THE ENVIRONMENT (DURABLE ADHESIVE MATERIALS MUST MEET THIS REQUIREMENT) COPYRIGHTED BY CASTILLO ENGINEERING SERVICES, LLC � ngineering v DESIGNED TO PEEMIT- CASTILLO ENGINEERING SERVICES, LLC COA#28345 2361 CREST RIDGE COURT SANFORD,FL32771 TEL 407474.9181ERMOCRATES E CASTILLO -FL PE S2590 REVISIONS DESCRIPTION DATE I REV PROJECT DEVELOPER APR 16 lute GEN• No 0 �C/ 5 AT O F • O R 1vP:r��=;� W U Ln W U M 0 Q —1 _ Z LL, W Z U LLI a IL Lo C3)O O LL =SHEENA SHEET SIZE ANSI B 11" X 17" SHEET NUMBER E-03 4/16/2018 PVWatts Calculator ;..NREL �-y ;RESULTS i 7,592kWh/Year* calculated UY�WYJa45�ol .de ! predictions inherent System output may range from 7,174 to 7,957kbyh per year near this location. i coon/ assnnaaom and uruertalnues and do not reflect variations 1 between Pv technologies nor silo spedlic chara[haissia except as represented by Month Solar Radiation AC Energy j Energy Value ! PVWads@ Inputs. For example, PV modules i i (kWh) ($) } th better performance are not differentiated vriWn PVW=(t hom lesser ( kWh m2 / day) } performing modules Bath NREL and private ! January 4.47 60 } companies provide more sophisticated PV 577 ' modelug tools (such as the System Aid+7<or Model at http://sam.nrd.gw) that allow for } February 4.92 575 60 mare precise and complex modefng of PV ' ry50ems i March 5.54 700 73 The expected range is based on 30 years of ! actual vreatW data at the gis n location and is intended to provide an indiation of ; April 5.80 703 f 73 the variation you might see. For more I i information, please refer to this NREL report ! , May 5.58 703 73 1 Th. Error Report t i June 5.26 630 66 i D.dalmer. The P'^Wa°s° Model (-Modem) July 5.54 684 71 is provided by the National Renewable EpprtJy Laboratory (°NREL), which is 1 operated by the Alliance for Sustainable } August 5.53 683 71 Energy, LLC (°Alliance') for the U.S. f Energy C and maybe Op ' September 5.28 632 66 used rtmentt p The names DOWN11 /ALLIANCE shaft not I October 4.93 614 k 64 be used In any representation advertising publicity or other manna whatsoever to endorse or promote any erdAy that adopt, or ( November 4.47 550 57 uses the Model. DOE/NREL/ALLDWCE shall i not provide ( -December 4.19 642 56 i any support, consulting, training or ' } _assistanceofam/Idndwthregardtotheuse_ of the Mom or any updates, revisions, err i Annual — -5.13 - — - 7,593 $ 790 i new versions of the Model. YOU AGREE TO INDEMNIFY t DOE/NREL/ALLIANCE, AND ITS AFFILIATES, E OFFICERS, AUNTS, AND EMPLOYEES ; Location and Station'Identification i AG4N5T ANY CLAIM OR DEMAND, AGAINST INCLUDING REASONABLE ATTORNEYS i1 ! RELATEOPTION To YOUR USE, Requested Location 9501 Poinciana Ct Fort Pierce, FL 34951 USA FOR AN, OR ADOPTION OF THE MODEL FOR ANY OR A j q ; PURPOSE WHATSOEVER. THE MODEL IS ` PROVIDED BY DOEINRWALLUWCE -AS Is' Weather Data Source (TMY2) WEST PALM BEACH, FL 59 mi AND ANY E%PRESS OR IMPLIED WARRANTIES, INCLUDING BUT NOT LIMITED TO THE IMPLIED WARRANTIES OF } Latitude 26.68o N MERCHAMABILITY AND FITNESS FOR A 1 i PARTICULARPURPOSE ARE EXPRESSLY I Longitude 80.1• W DISCLAIMED.. IN NO EVENT SHALL ; 9 DOE/NREL/ALLIANCE BE LIABLE FOR ANY } SPECIAL, INDIRECT ORA CONSEQUENTIAL 1 PV System $ ecifications y Residential I DAMAGES OR ANY DAMAGES WHATSOEVER, INCLUDING BUT NOT LIMITED 7O CLAIMS � -P { i ASSOCIATED WITH THE LOW OF DATA OR PROFns, WHICH MAY RESULT FROM ANY DC System Size 5.31 kW } } ACTION IN CONTRACT, NEGLIGENCE OR f OTHER TORTIOUS CLAIMCM THATARISES OUT } Module Type Standard OF OR IN CONNECTION WnH THE USE OR I PERFORMANCE OF THE MODEL. Array Type Fixed (open rack) } The energy output range Is based on i ! analysis of 30 years of historical ova dre data for nearby , and Is intended to provide A Array 1111 22.6° i an indication M the possible inleranwal ! variability In generation for a R-d (open Arra Azimuth 180• rack) PV system at this motion. Y a System Losses 14% i Inverter Efficiency 96% i DC to AC Size Ratio 1.1 Economics S Average Cost of Electricity Purchased 0.10 S1kWh E from Utility----- ---- -- ------- Performance Metrics � } s 1 Capacity Factor 16.3% http://pvwatts.nrel.gov/pvwatts.php W Castillo Engineering DESIGNED TO PERMIT!' CASTILLO ENGINEERING SERVICES, LLC COA M 28345 2381 CREST RIDGE COURT SANFORD,FL32771 TEL' 407-474-91BIERMOCRATES E. CASTILL.O -FL PE SMO REVISIONS — DESCRIPTION DATE REV PROJECT DEVELOPER APR 16 oe� old ono O 90 —N _ -2 ST E OF id���` g�s�ddlogoLLJ r Z UM W LL /� VJ w U LLI �U Ow � c J 110 (3) 0 0 SHEET NAME PV WATTS SHEET SIZE ANSI B 11" X 17" SHEET NUMBER P-01 With its top performance and completely black design the new QYEAK BLK-134.1 is the ideal solution for all residential rooftop applications -thanks-to its innovative cell technology UNTUIIJI. The world -record cell design was developed to achieve the best performance -under real-condi--- - - tions - even with low radiation intensity and on clear, hot summer days. LOW, ELECTRICITY GENERATION COSTS G Higher yield per surface area and lower BOS costs thanks to higher power classes and an efficiency rate of up to 18.3%. INNOVATIVE ALL-WEATHER TECHNOLOGY Optimal yields, whatever the weather with excellent low -light and temperature behavior. ENDURING HIGH. PERFORMANCE Long-term yield security with Anti-PID Technology', Hot -Spot -Protect and Traceable Quality Tra.QTM. EXTREME WEATHER RATING High-tech aluminum alloy frame, certified for high snow (5400Pa) and wind loads (4000Pa) regarding IEC. MAXIMUM COST REDUCTIONS Up to 10% lower logistics costs due to higher module capacity per box. O A RELIABLE INVESTMENT Inclusive 12-year product warranty and 25-year linear performance guarantee2. THE IDEAL -SOLUTION FOR: Rooftop arrays on -, residential buildings ocaLs '. nsos¢uam " . TOP MKHD PV i �. 2016, ` Ph Mn OuaNty Tested '00alls +.y,rama Best polyarItallim °i�06iOoi Sal rmadule 2014 ID; 40032587 . - - -- - I APT test conditions: Cells at -1500V against grounded, with conductive me- tal foil covered module surface, 25•C, 168h 2 See data sheet on rear for further information. Engineered in Germany QCRLS SPECIFICATIONMECHANICAL Formal 65.7 in x 39.4 in x 1.26 in (including frame) (1670 mm x 1000 mm x 32 mm) Weight 41.451bs(18.8kg) Froth Cover 0.13in (3.2mm) thermally pre -stressed glass with anti -reflection technology Back Cdver Composite film Frame Black anodized aluminum Cell 6 x 10 monocrystalline Q.ANTUM solar cells ltinction tiax 2.60-3.03 in x 4.37-3.54in x 0.59-0.75 in (66.77 mm x 111-90mm x 15-19mm), Protection class IP67, with bypass diodes Cable 4mm2 Solar cable; (+) a39.37in (1000mm), (-) a39.37in (1000mm) Am- 0f1P1 Connector Multi -Contact MC4 or MC4 intermateable, IP68 t----I �-• a�-waei T-Oi .POWER CLASS _ .. ' '. _ 290 . 295 300 MINIMUM PERFORMANCE AT STANDARD TEST CONDITIONS, STC' (POWER TOLERANCE +SW/ -OW) Power at MPP2 P,oe 1W] 290 I 295 300 Short Circuit.Currihe I [A] _ 9.63 9.70 9.77 Open Circuit Vc ltage• " . -- V� . , . M 39.19 - ", I 39.48 39.76 E - .E Content at MPP• Im [A] 9.07 1 9.17 9.26 voitageat"MPP• v_ M 31.96 1 32.19 32.41 Efrc]ency2 n [�k] . 217.4 i a17.7 - 218.0 MINIMUM PERFORMANCE AT NORMAL OPERATING CONDITIONS, NBC' Power at MPP' P" [W] 214.4 218.1 221.8 e Short_ CircuitCurreht• lu [A] 7.77 7.82 7.88 -E-Open.Circuit Voltage* - - - - - _ _ Vm [Y] - 36.65- - - - - _ 36.92 -" - " - .37.19' .2: Current at MPP• I- EA] 7.12 - - - -720- - - -- -- - _ _ _ _ 7.27 _ Voltage at MPP' V_ IV] 30.12 30.30 30.49 s1000W/m'. 250C=spectrum AM 1.5G 'Measurement tolerances STC t3%; NOC x5% 3800W/m'. NOCT, spectrum AM 1.5G -typical values, actual values may differ Q CELLS PERFORMANCE WARRANTY - - - _ - • . - _ PERFORMANCE AT LOW IRRADIANCE - At least 98%of nominal power during first year. X s'0 --� -----I -------------- i Thereafter max. 0.6%degradation per year. e -- ----------------------- At least 92.6% of nominal power up to 10 years. �------------------ At (east 83.6% of nominal power up to 25 years. m W I g All data within measurement tolerances. ? so--�---- r----y-----i-----� Full warranties in accordance with the warranty I I I 1 terms of the Q CELLS sales organisation of your m respective country. m coo .00 am ® ,mo h LL IRRADIANCE[WAa•1 Is ro 1° A Typical module performance under low irradiance conditions in .roOv. °,,n,., 'e.,,e9. •..caw 'n°As comparison to STC conditions (25°C. 1000W/m2). TEMPERATURE COEFFICIENTS - Temperature coefficient of 1. a (%/Kl +0.04 Temperature. Coefficient of Ym P [%/K] -0.28 Temperature Coefficient of P,D, Y [%/K] -0.39 Normal Operating Cell Temperature NOCT - [°FI 113 m5.4 (45 m3 °C) PROPERTIESr DESIGN Maxlmom.Spstem Voltage V_ M 1000 (IEC) / 1000 (UL) SafoO Class II Maximum Series Fuse Rating [A DC] 20 rare Rating C (IEC) ! TYPE 1 (UL) Oaslgnload, push(UL)I (Ibs/ft2] 75(3600Pa) Permittedmodul6temperature-40°Fupto+185°F can continuotis duty (-40 °C up to +85'C) Desigri lead, pull (ULP [Ibs/IN] 55.6 (2666 Pa) 2 see installation manual QUALIFICATIONS 1 CERTIFICATES PACKAGING INFORMATION UL 1703; VDE Quality Tested; CE-compliant; Number of Modules per Pallet 32 IEC 61215 (Ed.2h IEC 61730 (Ed.]) application class A Humberof Pallets per 53' Container 30 C ♦ C Ae Numbei Df Pallets per 40' Container 26 EVE C O US Pailet0imensicns (L x W'x H) 68.7 in x 45.3 in x 46.1 in w- (1745mm x 1150mm x 1170mm) Pallet Weight 1435lbs (651 kg) NOTE: Installation instructions must be followed. See the installation and operating manual or contact our technical service department for further information on approved installation and use of this product. Hanwha QCELLS America Inc. 300 Spectrum Center Drive, Suite 1250, Irvine, CA 92618, USA I TEL+1 949 748 59 96 1 EMAIL inquiryOus.q-cells.com I WED www.q-cells.us r.ngineering v DESIGNED TO PERMIT. CASTILLO ENGINEERING SERVICES, LLC COA028345 2381 CREST RIDGE COURT SANFORD, FL 32771 TEL: 407-474-9181ERMOGRATES E CASTILLO -FL PE 62590 REVISIONS DESCRIPTION DATE REV PROJECT DEVELOPER APR \" 'Y el I OV 0 2 9 STA: OF o •••• ,c O p ; �Zto ; PR Jeq 6I a p0000 W � Z 0M W 0 Z LL Q LU U U Z IS') O � 0 SHEET NAME DATA SHEET SHEET SIZE ANSI B 11" X 17" SHEET NUMBER DS-01 solar-. -. Single Phase Inverters for North America SE3000H-US/SE3800H-US/SE5000H-U SE6000H-US / SE760OH-US / SE1000OH-US 0 solar� =­ _V-D— _7 00 f 00timized instql'iaiildir'iWith'AD-Wave technology w, Speci c; fi 'illy.designed to work iMth'poWer optimizers -kkord-breaking efficiency n!"fixed voltage inverter for longer strings w 'Integrated. arc fault protection and rapid shutdown for NEC 2014 and 2017, per article 690,.11 and 690.12 UL . 1,741 SA certified, fied, for . CPUC-RuIe 21 grid compliance W Extremely small - High reliability Without any electrolytic capacitors - Built-in module -level monitoring — Outdoor and indoor installation wave Optional: Revenue grade data, ANSI C12.20 Class 0.5 (0.5% accuracy) USA-CANADA-GERMANY-UK-ITALY-THE r4ETHERLANDS-JAPAN-CHINA-AUSTRALIA-ISRAEL-FRANCE-BELGIUM-TURKEY-INDIA-BULGARIA-ROMANIA-HUNGARY-SWEDEN- www.solaredge.us SOUTH AFRICA-POLAND-CZECH REPUBLIC Sola r =Ig Single Phase Inverters for North America SE3000H-US I SE380OH-US SE5000H-US SE6000H-US/ SE760OH-US SE1000OH-US SE3000H-US I SE380OH-US SESOOOH-US SE6000H-US SE7600H US SE10000H-US OUTPUT Rated AC Power Output 3000 3500 5000 6000 Max. AC Power Output 3000 3800 5000 i666 .... 10000 VA ACOutput Voltage Min.-Nom.- ....... ...... Vac 2154) .... ...... ............... AC Frequency (Nominal) .................... .................... .................... 59:3.:6 ....... ....... -60.54) .............. .................... .... z ..... maximum Continuous Output 12.5 .............. * ............... 16 21 ...... ­ 25 ......... ...... 32 ......... ......... 42 ... ...... A .... I ................. ........... I ........ .................... .................... .... I ............... .................... .... ...................... Utility Monitoring, Islanding ............................................................... ......................................... .................... ..... Yes Protection, Country Configurable INPUT ..Maximum DC Power ................. ....... 4q5p ....... I ....... 590�0 ...... 11 .......7750 9300.......11800...... I ...... 1550 ....... .... w ..... Transformer -less, Ungrounded ...... ................... ......... ................. .......Yes .................................... ....................... ... ..Maximum Input Voltage ......................................... . .... !§q Vdc .............. .�....I- ................................. Nominal DC Input Voltage 380 400 Vdc ........ ....... I ........ ........ ........ i6.5 2 ...... ........ 27 ... * ' ..Maximum .... ....... ........ .................... .......... ...... ............ ... .......... ........I .................... ...... Xii Circuit Current . . . . . . . . . . . . . . . . . . . . . . . . . ........ ......_. .-...... ................... ....... ............ Adc ........................................... y...................................................... PolarityReverse Protection Yes Ground -Fault jsRlatDetection 600koSensitv�........M....... .......... ...M........'m'.......................a......... :- Maximum InKenerEffi3Oen99:2 ............................o.. Maximum ............ ....... ............. _f�yqight d Efficiency 99 ............................................ ...... ...... I .......... a..a. .......................... a ........ ... Nighttime Power Consumption I < 2.5 ADDITIONAL FEATURES RS485, Ethernet, ZigBee (optional), Cellular (optional) Interfaces......................... * .. ..... .......... ­* ... ­ ........ ' .......... ......... ........... .Rev.enuq.G.ra.d.eD.a.t.a.,.A,NS.I.Cl.2..20 .. .......... .............................................. C.Ption.a.11? .................................................. I ...... ........... ................ . . 'Shutdown' . . NEC 2 . 014 .. and 2017690.12 Automatic Rapid Shutdown upon AC Grid Disconnect STANDARD COMPLIANCE 07 .W�ty ............................. .................. ........... Grid Connection Standards IEEE1547, Rule 21, Rule 14 ......... ............................... ........................................................................ - missions FCC Part 15 Class B I Ran e ........... ................. DC Input Conduit Size / # of Strings / AWG Range ... .................................... Dimensions with Safety Switch (HxWxD) ........................................ Weight with Safety Switch ........... Noise co(;h�j ... * ........ * ....... * ....... .......... .Operating Temperature Range.. .. Protection Ra ng� ................... ... ­j�...... to For other regional settings please contact Solar Revenue grade inverter P/N; SEu H-USOOON P to For power de -rating Information refer to: https 01 -40 version P/N: SEI H-USOOONNU4 0 L Irs- 3/4" minimum / 20-4 AWG ........................................................................................................ ............................... 3/4" minimum 3/4" minimum / 1-2 strings / 14-6 AWG 1-3 strings 14 6 AWG ........... .................................................................................................. ..................... 21.3 x 14.6 x 17.7 x 14.6 x 6.8 450 x 370 x 174 7.3 / 540 x 370 in / mm ......................................... ..................................... 22/10 26.2 / 11.? ... ....... .... .. lb/k .... 'K.. ............ ....... ......... .................... < ig < 50" dBA ........... .. .................................................. ......................................... Convection ........... .......................I........ ................................I........ -13to+140/-25tc)+6o("(-40*F/-4o'CO ppqn) ..................................... ............... ............. ........................ ...... .......................................... � Ei�� iI ........ wi h Sa Vswitch)......... ............................... .... ........... Mile support C2 liw mlaredge.mm/sites/default/files/se-tempemtum-demdng-note-na.pdf engineering w-, DESIGNED TO PERMIT- CASTILLO ENGINEERING SERVICES, LLC COA#28345 2381 CREST RIDGE COURT SANFORD, FL32771 TEL"407-474-9181ERMOCRATES I- CASTILLO - FL PE 52590 REVISIONS DESCRIPTION DATE REV F PROJECT DEVELOPER ,jp ®I loll %% 4, G N 25 0 a S E O\ T ..OR\ P 0 SHEET NAME DATA SHEET SHEET SIZE ANSI B 11" X 17" SHEET NUMBER DS-02 solar=@a SolarEdge Power Optimizer Module Add -On For North America P300 / P320 / P400 / P405 solar=@@SolarEdge Power Optimizer Module Add -On for North America P300 / P320 / P400 / P405 0300 P320 P400 P405 (for60-cell modules) (for high -power (for 72&96-cep (for thin film 60-cell modules), modules) I modules) Rated Input DC Power1�1 3400 I 405 3.....00 20 ? W Absolute Maximum Input Voltage ................................... ........ 48 80 125 ( Vdc (Voc at lowest tem erature MPPT Operating Range 8 - 48 8 - 80 I 12:5 -105 .. Vdc Maximum Short Circuit en Currt (Isc) ..... .... _... 30 11 10 ............................................. Adc Maximum DC Input Current.......................12:5..................... . A7� 5..............................Adc..... MaximumEfficiencY........................................................................... ......................... .......... 99:5............................................................ %...... Weighted Efficiency 98.8 % OvervoltaRe Cateeory ..................................................................................I........ 1 II OUTPUT DURING OPERATION (POWER OPTIMIZER CONNECTED TO OPERATING SOLAREDGE INVERTER) - .. Maximum Output Current ............................... lr'................. ....Adc..... ........... .......... ............................I Maximum Output Voltage Maximum i 60 i 85 � Vdc -OUTPUT DURING-STAND&Y(POWER OPTIMIZER DISCONNECTED FROM SOLAREDGE INVERTER OR SOLAREDGE INVERTER OFF) �• _ Safety Output Voltage per Power - -- - - - - - - 1 Vdc- m m_ Optimizer STANDARD COMPLIANCE EMC...................................................................FCC Part15 Class B, IEC61000:6-2, IEC61000-6-3 ................... ! AN............ ................... ....... .................................... IEC62109-1(clal safety), UL1741................................... f.............. o Yes I NSTALLATI0N :SPECIFICATIONS Maximum Allowed System Voltage 1000 Compatible inverters .... All SolarEdge Single Phase and Three Phase inverters . Dimensions (W x L x H) 128 x 152 x 27 5 / 128 x 152 x 35 / I 12*'8' x 48 / Sx597x108 Sx597x137 Sx5.97x1.89 Weight (Including cables) 770 / 1 7 930 / 2 05............... 930 / 205........ Input Connector........................................................................MC4 Compatible........... Out utWireT a Connector ......P............Y.P..�..........................................................Double Output Wire Length ........................................... Insulated; MC4 Compatible...... 0:95 3:C....................... �.......................1:? 39.......... ............. Operating Temperature Range . 40 -+85 / :40 -+185............................................ Protection Rating........................................................................IP68 ...................... / NEMA6P ................................................. Relative Hum(di 0 -1.00 I'I Rated STC power of the module. Module of up to.5% power tolerance allowed. PV SYSTEM DESIGN USING SINGLE PHASE THREE PHASE 208V THREE PHASE 480V A SOLAREDGE INVERTER I2j Minimum String Length (Power Optimizers) .. Maximum String Length (Power Optimizers) Maximum Power per String., Parallel Strings of Different Lengths or Orientations .............................................. .. PI It is not allowed to mix P405 with P300/P400/P600/P700 in one string. USA - GERMANY - ITALY - FRANCE - JAPAN - CHINA - ISRAEL - AUSTRALIA www.solaredge.us 8 ..................I.................1 ...................................................... 25 25 50 ............................................................................................................ 5250 I ...... 6000 ............................. 12750.................... W...... Yes Engineering %SovI DESIGNED TO PERMIT+' CASTILLO ENGINEERING SERVICES, LLC COAB28945 2381 CREST RIDGE COURT SANFORD,FL32771 TEL: 407.47"181ERMOCRATES I- CASTILLO - FL PE 52693 REVISIONS DESCRIPTION DATE REV PROJECT DEVELOPER 16/ t! CAST/4 ems►•, , 590 T TE OF < 09 < •' I�� e� PROJ4is9 w Z U � W Q M Q J Z LL Q � U u W L ZV (n IL d ` U7 IX J °' O O u_ SHEET NAME DATA SHEET SHEET SIZE ANSI B 11"X 17" SHEET NUMBER DS-03 OUNIRAC A HIITI GROUP COMPANY SolarMount Technical Datasheet Pub 100602-1td V1.0 June 2010 SolarMount Module Connection Hardware.................................................................. 1 BottomUp Module Clip.................................................................................................1 MidClamp....................................................................................................................2 EndClamp....................................................................................................................2 SolarMount Beam Connection Hardware......................................................................3 L-Foot...........................................................................................................................3 SolarMountBeams..........................................................................................................4 SolarMount Module Connection Hardware BE SolarMount Bottom Up Module Clip Part No. 321001, 321002 I i 1 I Lzd L --� -I �. X 0 - ' Dimensions specified in inches unless noted • Bottom Up Clip material: One of the following extruded aluminum alloys: 6005-T5, 6105-T5, 6061-T6 • Ultimate tensile: 38ksi, Yield: 35 ksi • Finish: Clear Anodized • Bottom Up Clip weight: -0.031 Ibs (14g) • Allowable and design loads are valid when components are assembled with SolarMount series beams according to authorized UNIRAC documents • Assemble with one 1/4"-20 ASTM F593 bolt, one 1/"-20 ASTM F594 serrated flange nut, and one 1/4" flat washer • Use anti -seize and tighten to 10 ft-Ibs of torque • Resistance factors and safety factors are determined according to part 1 section 9 of the 2005 Aluminum Design Manual and third - party test results from an IAS accredited laboratory • Module edge must be fully supported by the beam * NOTE ON WASHER: Install washer on bolt head side of assembly. DO NOT install washer under serrated flange nut Applied Load Direction Average Ultimate Ibs (N) Allowable Load Ibs (N) Safety Factor, FS Design Load Ibs (N) Resistance Factor, m Tension, Y+ 1566 (6967) 686 (3052) 2.28 1038 (4615) 0.662 Transverse, X± 1128 (5019) 329 (1463) 3.43 497 (2213) 0.441 Sliding, Z± 66 (292) 1 27 (119) 1 2.44 41(181)1 0.619011 SolarMount Mid Clamp Part No. 320008, 320009, 320019, 320020, 320021, 320084, 320085, 320086, 320087, 320120, 320122 ti Ch - --- - 1.00 DISTAN BETWEEN MODULES 1 Y L.'X Dimensions specified in inches unless noted SolarMount End Clamp Part No. 320002, 320003, 320004, 320005, 320006, 320012, 320013, 320014, 320015, 320016, 320017, 320079, 320080, 320081, 320082, 320083, 320117, 320118, 320123, 320124, 320173, 320185, 320220, 320233. 320234. 320331 =-► X L 1.5 MINIMUM - HEIGHT VARIES WITH MODULE TMOOYEss r Dimensions specil P0TeS-`uRTeSS4iWeo • �an UNIRAC A HILT! GROUP COMPANY • Mid clamp material: One of the following extruded aluminum alloys: 6005-T5, 6105-T5, 6061-T6 • Ultimate tensile: 38ksi, Yield: 35 ksi • Finish: Clear or Dark Anodized • Mid clamp weight: 0.050 Ibs (23g) • Allowable and design loads are valid when components are assembled according to authorized UNIRAC documents • Values. represent the allowable and design load capacity of a single mid clamp assembly when used with a SolarMount series beam to retain a module in the direction indicated • Assemble mid clamp with one Unirac 1/4"-20 T-bolt and one 1/4"-20 ASTM F594 serrated flange nut • Use anti -seize and tighten to 10 ft-Ibs of torque • Resistance factors and safety factors are determined according to part 1 section 9 of the 2005 Aluminum Design Manual and third - party test results from an IAS accredited laboratory Applied Load _Direction Average Ultimate lbs (N)- Allowable Load ---Ibs-(N) Safety Factor, - --FS Design Load - -- Ibs-(N) Resistanc I-act�e� _ _,:! m Tension, Y+ 2020 (8987) 891 (3963) 2.27 1348 (5994) 1. CM67 Transverse, Z± 520 (2313) 1 229 (1017) 2.27 346 (1539) ($ Sliding, X± 1 1194 (5312) 1490 (2179) 1 2.441 741 (3295) a2a • End clamp material: One of the following extruded aluminum alloys: 6005-T5, 6105-T5, 6061-T6 • Ultimate tensile: 38ksi, Yield: 35 ksi • Finish: Clear or Dark Anodized • End clamp weight: varies based on height: -0.058 Ibs (26g) • Allowable and design loads are valid when components are assembled according to authorized UNIRAC documents • Values represent the allowable and design load capacity of a single end clamp assembly when used with a SolarMount series beam to retain a module in the direction indicated • Assemble with one Unirac 1/4"-20 T-bolt and one 1/"-20 ASTM F594 serrated flange nut • Use anti -seize and tighten to 10 ft-Ibs of torque • Resistance factors and safety factors are determined according to part 1 section 9 of the 2005 Aluminum Design Manual and third - party test results from an IAS accredited laboratory • Modules must be installed at least 1.5 in from either end of a beam Applied Load Direction Average Ultimate Ibs (N) Allowable Load Ibs (N) Safety Factor, FS Design Loads Ibs (N) Resistance Factor, m Tension, Y+ 1321 (5876) 529 (2352) 2.50 800 (3557) 0.605 Transverse, Zt1 63 (279) 14 (61) 1 4.58 21(92)1 0.330 Sliding, X± 1 142 (630) 52 (231) 1 2.72 79 (349) 0.555 ;0(, engineering v DESIGNED TO PERMIT- CASTILLO ENGINEERING SERVICES, LLC COA#28345 2381 CREST RIDGE COURT SANFORD, FL 32771 TEL: 407474-9181ERMOCRATES E CASTILLO - FL PE 52590 REVISIONS DESCRIPTION DATE REV PROJECT DEVELOPER Lp / B al I _r- i AT •1(/ Z Z. O N W Z U M W U- LV U U Z a- a W -� t� cr' G)O 0 Lt_ SHEET NAME DATA SHEET SHEET SIZE ANSI B 11" X 17" SHEET NUMBER DS-04 Round Standoff Series Installation Guide RS-3 / RS-4 / RS-6 / RS-7 Technical Specifications Material Type: 6o6i Aluminum Post Stainless Steel Base Mounting Points: 6 - 3/8 Holes Post Threads: 3/8 -16 UNC General Uplift: 1500 lbs (6 Attachments) Included: One 3/8-16 SHCS Bolt - - --Application: Barrel Tile / Flat Roof General Installation - Clean The Installation Site - Apply Sealant To Bottom Of Base - Use Lag Bolts To Secure Base To Roof - Mount L-Foot With 3/8 Bolt Provided - Connect L-Foot To Railing Always Adhere To Local Codes, Check With An Engineer For Site Specific Information Page 4 Engineering %L DESIGNED TO PIRMIT- CASTILLO ENGINEERING SERVICES, LLC COA k28345 2381 CREST RIDGE COURT SANFORD. FL 32771 TEL' 407-474-8181ERMOCRATES E. CASTILLO - FL PE 52590 REVISIONS DESCRIPTION DATE I REV AS T/�����i Sig Ouitb �' blo 5 59 ® CC ST • lU OF •4u, m — P 001e•�°°° W U LID W U M - z U_ LLj ZU 0W �- W U �. 0)0 2 SHEET NAME DATA SHEET SHEET SIZE ANSI B 11" X 17" SHEET NUMBER DS-05