HomeMy WebLinkAboutNOA.I'
J Fiib.
�OvH�'v
DEPARTHE NIT OF REGULATORY AND E(
BOARD AND CODE ADMINISTRATION DI
NOTICE OF ACCEPTANCE
CertainTeed Corporation
18 Moores Road
Malvern, PA 19355
SCOPE:
SCANNED
5V
RESOURCES (RER)
MIAMI-DADS COUNTY
PRODUCT CONTROL SECTION
11805 SW 26 Street, Room 208
Miami, Florida 33175-2474
T (786) 315-2590 F (786) 315-2599
www.miamidade.aov/economy
This NOA is being issued under the applicable rules and regulations governing the use of construction materials. The
documentation submitted has been reviewed and accepted by Miami -Dade County RER - Product Control Section to be
used in Miami Dade County and other areas where allowed by the Authority Having Jurisdiction (AHJ).
This NOA shall not be valid after the expirai
(In Miami Dade County) and/or the AHJ (in
or material tested for quality assurance purpi
manufacturer will incur the expense of such
of such product or material within their juris
determined by Miami -Dade County Product
of the applicable building code.
date stated below. The Miami -Dade County Product Control Section
Is other than Miami Dade County) reserve the right to have this product
. If this product or material fails to perform in the accepted manner, the
ng and the AHJ may immediately revoke, modify, or suspend the use
.on. RER reserves the right to revoke this acceptance, if it is
Itrol Section that this product or material fails to meet the requirements
This product is, approved as described herein, and has been designed to comply with the Florida Building Code
including the High Velocity Hurricane Zone of the Florida Building Code.
DESCRIPTION:Flintlastic Self -Adhered Roofing Systems Over.WoodDeclis "
LABELING: Each unit shall bear a permanent label with the manufacturer's name or logo, city, state and following
statement: "Miami -Dade County Product Control, Approved", unless otherwise noted herein.
RENEWAL of this NOA shall be considered after a renewal application has been filed and there has been no change in
the applicable building code negatively affecting the performance of this product.
TERMINATION of this NOA will occur afteI� the expiration date or if there has been a revision or change in the
materials, use, and/or manufacture of the product or process. Misuse of this NOA as an endorsement of any product, for
sales, advertising or any other purposes shall automatically terminate this NOA. Failure to comply with any section of
this NOA shall be cause for termination and removal of NOA.
ADVERTISEMENT: The NOA number preceded by the words Miami -Dade County, Florida, and followed by
the expiration date may be displayed in advertising literature. If any portion of the NOA is displayed, then it
shall be done in its entirety.
INSPECTION:.A copy of this entire NOA shall be provided to the user by the manufacturer or its distributors and shall
be available for inspection at the job site at the request of the Building Official.
This NOA revises NOA #15-0108.03 and consists of pages 1 through 19.
The submitted documentation was reviewed by Alex Tigera.
MIAMI•DADE COUNTY
NOA No.: 15-0622.21
Expiration Date: 04/13/20
Approval Date: 08/20/15
Page 1 of 19
ROOFING ASSEMBLY APPROVAL
Category Roofing
Sub -Category: Modified Bitumen
Material: SBS
Deck Tyne: Wood
Maximum Design Pressure -127.5 psl
TRADE NAMES OF PRODUCTS MANUFACTURED
OR LABELED BY APPLICANT:
TABLE 1
Product,._- £
Dimensions
Spec
Description
,.Flintlastic SA'NailBase
39 3/8" x 66'6' ; Ro11
ASTM D 4601; Type
Fiberglass reinforced, SBS modified
- weight: 82 lbs.
II
bitumen base sheet.
(2 squares)
All Weather/Empire Base
39 3/8" x 65' 10j';
ASTM D 4601 Type
Asphalt coated, fiberglass reinforced base
Sheet
Roll weight: 70 lbs.
U
sheet.
(2 squares)
UL Type G2
Yosemite Venting Base
39 3/s" x 3T10';
Roll
ASTM D 3909
Mineral Surfaced fiberglass reinforced
Sheet
weight: 85 lbsl.
ASTM D 4897, Type
buffer sheet.
(1 square)
I
II
UL Type G3
Flexiglas Base Sheet
39 3/8" x 98'9' ;Roll
ASTM D 4601, Type
Modified Bitumen coated fiberglass base
weight: 90lbs
�
II
sheet.
(3 squares)
UL Type G2
Flintlastic Poly SMS Base
39 3/s" x 64' 3';
oll
ASTM D 4601,
Modified Bitumen coated polyester base
Sheet
weight: 90 lbs!
Grade S, Type II
sheet.
(2 squares)
UL Type G2
Glasbase Base Sheet
39 3/s" x 98'9'; Roll
ASTM D 4601 Type
Asphalt coated, fiberglass base sheet.
weight: 75 lbs j
II
(3 squares)
UL Type G2
Flintlastic Ultra Poly
39 3/8" x 32' 10"; R011
ASTM D 6164,
Smooth surfaced SBS Modified Bitumen
SMS Base Sheet
weight: 90 lbs!
Grade S, Type I
Membrane with non -woven polyester mat
(1 square)
reinforcement for mop applications.
Flint_la_s_tic_SA_F_
39 3/8" x 66'6"; Roll
ASTM D 1970
Self -adhering, fiberglass reinforced, SBS
_I_yBase _.
' -
weight: 861bs ,
modified bitumen base/ply sheet.
(2 squares)
Flintlastic SA Mid Ply
39 3/s" x 32' 1"
ASTM D 6163,
Self -adhering, polyester reinforced, SBS
Roll weight: 62 lbs.
Grade S, Type I
modified bitumen ply sheet.
(1 square)
I
NOA No.: 15-0622.21
CMIAMI, EcOUNTY
Expiration Date: 04/13/20
Approval Date: 0W20/15
Page 2 of 19
i
TRADE NAMES OF PRODUCTS MANUFACTURED OR LABELED BY APPLICANT:
TABLE 1
Product DimensionsilI Spec Description
Flintlastic SA Cap FR 39 3/8" x 32' 11";1Roll ASTM D 6163, Self -adhering, fiberglass reinforced, SBS
weight: 88"lbs. Grade G, Type I modified bitumen cap sheet.
(1 square)
Flintlastic SA Cap FR 39 3/8" x 32' 11' ;
CoolStar
weight: 90 lh
(1 square)
Flintlastic SA Cap_ _,
39 3/8" x 32' 11';
weight: 95 lb
(1 square)
Flintlastic SA Cap
39'A" x 32' 11'
CoolStar
weight: 98 lh
(1 square)
FlintPrime Asphalt 1, 3 or 5 gal
FlintPrime SA 1, 3 or 5 gal
APPROVED INSULATIONS:
Product
F1intBoard ISO, FlintBoard ISOH
ACFoam-II
ENRGY 3
H-Shield
Multi -Max FA-3
DensDeck, DensDeck Prime
SECUROCK Gypsum -Fiber Roof Board
ASTM D 6163, Self -adhering, fiberglass reinforced, SBS
Grade G, Type I modified bitumen cap sheet with
reflective coating.
ASTM D 6164, Self -adhering, polyester reinforced, SBS
Grade G, Type I modified bitumen cap sheet.
ASTM D 6164, Self -adhering, polyester reinforced, SBS
Grade G, Type I modified bitumen cap sheet with
reflective coating.
Asphalt primer
Proprietary
TABLE 2
Product Description
Polyisocyanurate insulation
Polyisocyanurate insulation
Polyisocyanurate. insulation
Polyisocyanurate insulation
Polyisocyanurate insulation
Gypsum coverboard
homogenous fiber reinforced
I
Water -based, polymer modified primer.
Manufacturer.
(with current NOA)
CertainTeed Corp.
Atlas Roofing Corp.
Johns Manville Corp.
Hunter Panels, LLC.
Rmax Operating, LLC.
Georgia Pacific Gypsum LLC.
USG Corp.
I
NOA No.: 15-0622.21
Expiration Date: 04/13/20
Approval Date: 08/20/15
Page 3 of 19
APPROVED FASTENERS:
Fastener
Number
1.
2.
3.
4.
5.
6.
7.
8.
9.
10.
1L
12.
13.
14.
Product Name
Dekfast 14
Trufast #14 HD Fastener
#14 Roogrip
OMG Heavy Duty
F1intFast #14 Fastener
Dekfast 12
#12 Standard Roofgrip
3 in. Round Metal Plate
Trufast #12 DP Fastener
F1intFast #12 Fastener
Dekfast Hex Plate
Flat Bottom Metal Plate
Trufast 3" Metal Insulation
Plate
F1intFast 3" Metal
Insulation Plate
TABLE 3
Product Description
Roofing screw
Roofing screw
Roofing screw
Roofing screw
Roofing screw
Roofing screw
Insulation fastener
3" round galvalume AZ50
steel plate
Roofing screw
Roofing screw
hexagonal steel plate
3" square steel plate
3" round steel plate
3" round steel plate
Manufacturer
(with current NOAI
SFS Intec, Inc.
Altenloh, Brinck & Co. U.S., Inc.
OMG, Inc.
OMG, Inc.
CertainTeed Corp.
SFS Intec, Inc.
OMG, Inc.
OMG, Inc.
Altenloh, Brinck & Co. U.S., Inc.
CertainTeed. Corp.
SFS Intec, Inc.
OMG, Inc.
Altenloh, Brinck & Co. U.S., Inc.
CertainTeed Corp.
0
NOA No.: 15-0622.21
MIAMI•DADE COUNTY Expiration Date: 04/13/20
Approval Date: 08/20/15
Page 4 of 19
APPROVED SURFACING/COATING
Chosen components must be applied accori
below, used as a surfacing, must be listed m
Svstem Manufacturer
Number
1. Generic
2. Generic
3. Karnak Corp.
4. CertainTeed Corp.
5. Gardner Asphalt Corp.
6. Gardner Asphalt Corp.
TABLE 4
to manufacturer's application instructions. Any coating, listed
o a current NOA.
Application
Gravel applied at 400 lbs/sq., adhered with flood coat of asphalt at 60
lbs/sq.
Slag applied at 300 lbs/sq., adhered with flood coat of asphalt at 60
lbs/sq.
Karnak (#97 AF) Fibrated Aluminum Roof Coating applied at an
application rate of 1.5 gal/sq.
FlintCoat A-150 applied at an application rate of 1.5 gal/sq.
APOC #212 Fibered Aluminum Roof Coating applied at an
application rate of 1.5 gal/sq.
APOC #400 Sunbrite applied at an application rate of 3 gal./sq.
i
i
NOA No.: 15-0622.21
MIAMbUADECouNTY Expiration Date: 04/13/20
Approval Date: 08/20/15
j Page 5 of 19
EVIDENCE SUBMITTED:
Test Agencv
Test Identifier
Description
Date
Underwriters Laboratories
R11656
UL790
Annually
Momentum Technologies, Inc.
DX08C4A
Physical Properties
03/22/04
DX20E3A
Physical Properties
03/22/04
Factory Mutual Research
3009610
FM 4450
10/15/01
2D5A9.AM
FM 4450
06/22/99
3014751
FM 4450
08/12/03
�014692
FM 4450
08/05/03
3012321
FM 4450
07/29/02
�008869
FM 4470
03/19/01
'037127
FM 4470
01/11/10
3039046
FM 4470
06/15/10
3048520
FM 4470
09/19/13
025766
FM 4470
11/13/06
Trinity ERD
3518.12.03
TAS 114-F/G/I
12/01/03
C35119.12.03-Rl
TAS 114-D/J & TAS 117(B)
04/15/11
0351�5.07.03-1-RI
TAS 1144 & TAS 117(B)
06/27/12
3§21.07.04
TAS 1144 & TAS 117(B)
07/28/04
3522.07.04
TAS 114-D
07/28/04
C31410.06.10
ASTM D 5147/4798
06/03/10
C7290.01.08
ASTM D 4601/1970
01/16/08
C8370.08.08-R1
TAS 114-1-1/J & TAS 117(B)
10/05/09
C8500SC.11.07 Rl
ASTM D 6862/TAS 117(B)
08/07/09
C310310.12.09
TAS 114 / TAS 117
12/17/09
C10080.09.08-R4
ASTM D 5147/6163/6.164
03/25/10
1
ASTM D 6222/3909
C10080.09.10-R1
ASTM D 5147 & 6163
11/18/10
60560.06.10
TAS 114/TAS 117
06/10/10
C32830.07.10
FM 4470 / TAS 114
07/20/10
62970.09.10
ASTM D 6163
09/16/10
3513.08.02-R1
TAS 114/TAS 117
03/17/11
C32970.04.11
ASTM D 6164
04/01/11
C35500.02.11
TAS 117(B)
02/09/11
C35460.05.11
ASTM D1876
06/16/11
C45620.03.14
ASTM D1876, TAS 114 (H),
03/27/14
FM 4474
C47350.50.14
FM 4470
05/22/14
C44580.07.13
ASTM D 1876,
07/25/13
TAS 114, FM 4474
C42110.0.8.12
TAS 114 & TAS 117
08/13/12
PRI Construction Materials
CTC-634-02-01 REV
ASTM D 6163
11/24/08
Technologies
CTC-032-02-01
ASTM D6163
01/22/08
CTC-066-02-01
ASTM D6163
08/09/11
CTC-070-02-01
ASTM D6222
08/09/11
NOA No.: 15-0622.21
CMAMM1-DADMECO=UNTY Expiration Date: 04/13/20
Approval Date: 08/20/15
Page 6 of 19
EVIDENCE SUBMITTED:
Test Agency Test Identifier
Description
i
CTC-093-02-01
ASTM D6164/4798
CT6122-02-01
ASTM D2178
CTC-123-02-01
ASTM D2178
CTC-127-02-01
ASTM D4601
CTC-128-02-01
ASTM D6163
CTC-129-02-01
ASTM D6163
CTC-132-02-01
ASTM D6164
CTC-162-02-01
ASTM D6164
CT6-161-02-01
ASTM D6164
CT6-183-02-01
ASTM D6162
CTC-190-02-01
ASTM D6164
CT6-199-02-01
ASTM D1970
I
MIA MI DARE COUNTY
Date
08/09/11
03/13/12
03/13/12
03/13/12
06/11/12
06/11/12
06/11/12
05/09/13
05/09/13
10/02/13
12/02/13
01/22/14
NOA No.: 15-0622.21
Expiration Date: 04/13/20
Approval Date: 08/20/15
Page 7 of 19
Membrane Type: SBS MODIFIED, SIELF-ADHERING
Deck Type 1:
Wood, Non -insulated
Deck Description:
Minimum 19/32" thick plywood attached using 8d ring shank nails spaced 6"o.c. at wood joists
spaced maximum 24" o.c.
System Type E(2):
Base sheet mechanically fastened.
All General and System Limitations apply.
Separation Sheet:
One ply of G1asBasa, Base Sheet, loose laid.
(Optional)
Base Sheet:
One or more layers of Flintlastic SA Nai1B_ase, mechanically attached as described below.
Fastening:
Fastened with FBC HVHZ nails and tin caps spaced 6" o.c. at the 3" lap and 6" o.c. in four,
equally spaced staggered center rows.
SA P1yBase or Flintlastic SA Mid Ply, -adhered.
Ply Sheet:
One or more layersfof Flintlastic self
(Optional)
Membrane:
One layer%of-Flintlastic-SA, Cap,_Flintlastic SA Cap CoolStar, Flintlastic SA Cap FR or
Flintlastic SA Cap FR CoolStar, self -adhered.
Surfacing: Any of the approved surfacing/coating options listed in Table 4.
(Optional)
Maximum Design -52.5 psf (See Gene�ul Limitation #7.)
Pressure:
NOA No.: 15-0622.21
Expiration Date: 04/13/20
Approval Date: 08/20/15
Page 13 of 19
WOOD DECK SYSTEM UwTATIONS:
1. A slip sheet is required with Ply 4 and Ply 6 when used as a mechanically fastened base or anchor sheet.
GENERAL LBUTATIONS:
1. Fire classification is not part of this acceptance; refer to a current Approved Roofing Materials Directory for fire
ratings of this product.
2. Insulation may be installed in multiple lay rs. The first layer shall be attached in compliance with Product Control
Approval guidelines. All other layers shall be adhered in a full mopping of approved asphalt applied within the
EVT range and at a rate of 20-40 lbs./sq., or mechanically attached using the fastening pattern of the top layer
3. All standard panel sizes are acceptable fo1r mechanical attachment. When applied in approved asphalt, panel size
shall be 4' x 4' maximum.
4. An overlay and/or recovery board insulation panel is required on all applications over closed cell foam insulations
when the base sheet is fully mopped. If no recovery board is used the base sheet shall be applied using spot mopping
with approved asphalt, 121' diameter circles, 24" o.c.; or strip mopped 8" ribbons in three rows, one at each,sidelap
and one down the center of the sheet allowing a continuous area of ventilation. Encircling of the strips is not
acceptable. A 6" break shall be placed every 12' in each ribbon to allow cross ventilation. Asphalt application of
either system shall be at a minimum rate 9f 12 lbs./sq.
5. Fastener spacing for insulation attachment is bused on a Minimum Characteristic Force (F') value of 275 lbf., as
tested in compliance with Testing Application Standard TAS 105. If the fastener value, as field-tested, are below
275 lbf. insulation attachment shall not bel acceptable.
6. Fastener spacing for mechanical attachment of anchor/base sheet or membrane attachment is based on a minimum
fastener resistance value in conjunction with the maximum design value listed within a specific system. Should the
fastener resistance be less than that required, as determined by the Building Official, a revised fastener spacing,
prepared, signed and sealed by a Florida registered Professional Engineer, Registered Architect, or Registered Roof
Consultant may be submitted. Said revised fastener spacing shall utilize the withdrawal resistance value taken from
Testing Application Standards TAS 105 and calculations in compliance with Roofing Application Standard RAS
117.
7. Perimeter and corner areas shall comply with the enhanced uplift pressure requirements of these areas. Fastener
densities shall be increased for both insulation and base sheet as calculated in compliance with Roofing Application
Standard RAS 117. Calculations prepared, signed and sealed by a Florida registered Professional Engineer,
Registered Architect, or Registered Roof Consultant (When this limitation is specifically referred within this
NOA, General Limitation #9 will not be applicable.)
8. All attachment and sizing of perimeter nailers, metal profile, and/or flashing termination designs shall conform with
Roofing Application Standard RAS 111 and applicable wind load requirements.
9. The maximum designed pressure limitation listed shall be applicable to all roof pressure zones (i.e. field,
perimeters, and comers). Neither rational 'analysis, nor extrapolation shall be permitted for enhanced fastening at
enhanced pressure zones (i.e. perimeters, extended corners and corners). (When this limitation is specifically
referred within this NOA, General Limitation #7 will not be applicable.)
10. All products listed herein shall have a quality assurance audit in accordance with the Florida Building Code and
Rule 61 G20-3 of the Florida Administrative Code.
END OF THIS ACCEPTANCE
NOA No.: 15-0622.21
Expiration Date: 04/13/20
Approval Date: 08/20/15
Page 19 of 19