Loading...
HomeMy WebLinkAboutNOA.I' J Fiib. �OvH�'v DEPARTHE NIT OF REGULATORY AND E( BOARD AND CODE ADMINISTRATION DI NOTICE OF ACCEPTANCE CertainTeed Corporation 18 Moores Road Malvern, PA 19355 SCOPE: SCANNED 5V RESOURCES (RER) MIAMI-DADS COUNTY PRODUCT CONTROL SECTION 11805 SW 26 Street, Room 208 Miami, Florida 33175-2474 T (786) 315-2590 F (786) 315-2599 www.miamidade.aov/economy This NOA is being issued under the applicable rules and regulations governing the use of construction materials. The documentation submitted has been reviewed and accepted by Miami -Dade County RER - Product Control Section to be used in Miami Dade County and other areas where allowed by the Authority Having Jurisdiction (AHJ). This NOA shall not be valid after the expirai (In Miami Dade County) and/or the AHJ (in or material tested for quality assurance purpi manufacturer will incur the expense of such of such product or material within their juris determined by Miami -Dade County Product of the applicable building code. date stated below. The Miami -Dade County Product Control Section Is other than Miami Dade County) reserve the right to have this product . If this product or material fails to perform in the accepted manner, the ng and the AHJ may immediately revoke, modify, or suspend the use .on. RER reserves the right to revoke this acceptance, if it is Itrol Section that this product or material fails to meet the requirements This product is, approved as described herein, and has been designed to comply with the Florida Building Code including the High Velocity Hurricane Zone of the Florida Building Code. DESCRIPTION:Flintlastic Self -Adhered Roofing Systems Over.WoodDeclis " LABELING: Each unit shall bear a permanent label with the manufacturer's name or logo, city, state and following statement: "Miami -Dade County Product Control, Approved", unless otherwise noted herein. RENEWAL of this NOA shall be considered after a renewal application has been filed and there has been no change in the applicable building code negatively affecting the performance of this product. TERMINATION of this NOA will occur afteI� the expiration date or if there has been a revision or change in the materials, use, and/or manufacture of the product or process. Misuse of this NOA as an endorsement of any product, for sales, advertising or any other purposes shall automatically terminate this NOA. Failure to comply with any section of this NOA shall be cause for termination and removal of NOA. ADVERTISEMENT: The NOA number preceded by the words Miami -Dade County, Florida, and followed by the expiration date may be displayed in advertising literature. If any portion of the NOA is displayed, then it shall be done in its entirety. INSPECTION:.A copy of this entire NOA shall be provided to the user by the manufacturer or its distributors and shall be available for inspection at the job site at the request of the Building Official. This NOA revises NOA #15-0108.03 and consists of pages 1 through 19. The submitted documentation was reviewed by Alex Tigera. MIAMI•DADE COUNTY NOA No.: 15-0622.21 Expiration Date: 04/13/20 Approval Date: 08/20/15 Page 1 of 19 ROOFING ASSEMBLY APPROVAL Category Roofing Sub -Category: Modified Bitumen Material: SBS Deck Tyne: Wood Maximum Design Pressure -127.5 psl TRADE NAMES OF PRODUCTS MANUFACTURED OR LABELED BY APPLICANT: TABLE 1 Product,._- £ Dimensions Spec Description ,.Flintlastic SA'NailBase 39 3/8" x 66'6' ; Ro11 ASTM D 4601; Type Fiberglass reinforced, SBS modified - weight: 82 lbs. II bitumen base sheet. (2 squares) All Weather/Empire Base 39 3/8" x 65' 10j'; ASTM D 4601 Type Asphalt coated, fiberglass reinforced base Sheet Roll weight: 70 lbs. U sheet. (2 squares) UL Type G2 Yosemite Venting Base 39 3/s" x 3T10'; Roll ASTM D 3909 Mineral Surfaced fiberglass reinforced Sheet weight: 85 lbsl. ASTM D 4897, Type buffer sheet. (1 square) I II UL Type G3 Flexiglas Base Sheet 39 3/8" x 98'9' ;Roll ASTM D 4601, Type Modified Bitumen coated fiberglass base weight: 90lbs � II sheet. (3 squares) UL Type G2 Flintlastic Poly SMS Base 39 3/s" x 64' 3'; oll ASTM D 4601, Modified Bitumen coated polyester base Sheet weight: 90 lbs! Grade S, Type II sheet. (2 squares) UL Type G2 Glasbase Base Sheet 39 3/s" x 98'9'; Roll ASTM D 4601 Type Asphalt coated, fiberglass base sheet. weight: 75 lbs j II (3 squares) UL Type G2 Flintlastic Ultra Poly 39 3/8" x 32' 10"; R011 ASTM D 6164, Smooth surfaced SBS Modified Bitumen SMS Base Sheet weight: 90 lbs! Grade S, Type I Membrane with non -woven polyester mat (1 square) reinforcement for mop applications. Flint_la_s_tic_SA_F_ 39 3/8" x 66'6"; Roll ASTM D 1970 Self -adhering, fiberglass reinforced, SBS _I_yBase _. ' - weight: 861bs , modified bitumen base/ply sheet. (2 squares) Flintlastic SA Mid Ply 39 3/s" x 32' 1" ASTM D 6163, Self -adhering, polyester reinforced, SBS Roll weight: 62 lbs. Grade S, Type I modified bitumen ply sheet. (1 square) I NOA No.: 15-0622.21 CMIAMI, EcOUNTY Expiration Date: 04/13/20 Approval Date: 0W20/15 Page 2 of 19 i TRADE NAMES OF PRODUCTS MANUFACTURED OR LABELED BY APPLICANT: TABLE 1 Product DimensionsilI Spec Description Flintlastic SA Cap FR 39 3/8" x 32' 11";1Roll ASTM D 6163, Self -adhering, fiberglass reinforced, SBS weight: 88"lbs. Grade G, Type I modified bitumen cap sheet. (1 square) Flintlastic SA Cap FR 39 3/8" x 32' 11' ; CoolStar weight: 90 lh (1 square) Flintlastic SA Cap_ _, 39 3/8" x 32' 11'; weight: 95 lb (1 square) Flintlastic SA Cap 39'A" x 32' 11' CoolStar weight: 98 lh (1 square) FlintPrime Asphalt 1, 3 or 5 gal FlintPrime SA 1, 3 or 5 gal APPROVED INSULATIONS: Product F1intBoard ISO, FlintBoard ISOH ACFoam-II ENRGY 3 H-Shield Multi -Max FA-3 DensDeck, DensDeck Prime SECUROCK Gypsum -Fiber Roof Board ASTM D 6163, Self -adhering, fiberglass reinforced, SBS Grade G, Type I modified bitumen cap sheet with reflective coating. ASTM D 6164, Self -adhering, polyester reinforced, SBS Grade G, Type I modified bitumen cap sheet. ASTM D 6164, Self -adhering, polyester reinforced, SBS Grade G, Type I modified bitumen cap sheet with reflective coating. Asphalt primer Proprietary TABLE 2 Product Description Polyisocyanurate insulation Polyisocyanurate insulation Polyisocyanurate. insulation Polyisocyanurate insulation Polyisocyanurate insulation Gypsum coverboard homogenous fiber reinforced I Water -based, polymer modified primer. Manufacturer. (with current NOA) CertainTeed Corp. Atlas Roofing Corp. Johns Manville Corp. Hunter Panels, LLC. Rmax Operating, LLC. Georgia Pacific Gypsum LLC. USG Corp. I NOA No.: 15-0622.21 Expiration Date: 04/13/20 Approval Date: 08/20/15 Page 3 of 19 APPROVED FASTENERS: Fastener Number 1. 2. 3. 4. 5. 6. 7. 8. 9. 10. 1L 12. 13. 14. Product Name Dekfast 14 Trufast #14 HD Fastener #14 Roogrip OMG Heavy Duty F1intFast #14 Fastener Dekfast 12 #12 Standard Roofgrip 3 in. Round Metal Plate Trufast #12 DP Fastener F1intFast #12 Fastener Dekfast Hex Plate Flat Bottom Metal Plate Trufast 3" Metal Insulation Plate F1intFast 3" Metal Insulation Plate TABLE 3 Product Description Roofing screw Roofing screw Roofing screw Roofing screw Roofing screw Roofing screw Insulation fastener 3" round galvalume AZ50 steel plate Roofing screw Roofing screw hexagonal steel plate 3" square steel plate 3" round steel plate 3" round steel plate Manufacturer (with current NOAI SFS Intec, Inc. Altenloh, Brinck & Co. U.S., Inc. OMG, Inc. OMG, Inc. CertainTeed Corp. SFS Intec, Inc. OMG, Inc. OMG, Inc. Altenloh, Brinck & Co. U.S., Inc. CertainTeed. Corp. SFS Intec, Inc. OMG, Inc. Altenloh, Brinck & Co. U.S., Inc. CertainTeed Corp. 0 NOA No.: 15-0622.21 MIAMI•DADE COUNTY Expiration Date: 04/13/20 Approval Date: 08/20/15 Page 4 of 19 APPROVED SURFACING/COATING Chosen components must be applied accori below, used as a surfacing, must be listed m Svstem Manufacturer Number 1. Generic 2. Generic 3. Karnak Corp. 4. CertainTeed Corp. 5. Gardner Asphalt Corp. 6. Gardner Asphalt Corp. TABLE 4 to manufacturer's application instructions. Any coating, listed o a current NOA. Application Gravel applied at 400 lbs/sq., adhered with flood coat of asphalt at 60 lbs/sq. Slag applied at 300 lbs/sq., adhered with flood coat of asphalt at 60 lbs/sq. Karnak (#97 AF) Fibrated Aluminum Roof Coating applied at an application rate of 1.5 gal/sq. FlintCoat A-150 applied at an application rate of 1.5 gal/sq. APOC #212 Fibered Aluminum Roof Coating applied at an application rate of 1.5 gal/sq. APOC #400 Sunbrite applied at an application rate of 3 gal./sq. i i NOA No.: 15-0622.21 MIAMbUADECouNTY Expiration Date: 04/13/20 Approval Date: 08/20/15 j Page 5 of 19 EVIDENCE SUBMITTED: Test Agencv Test Identifier Description Date Underwriters Laboratories R11656 UL790 Annually Momentum Technologies, Inc. DX08C4A Physical Properties 03/22/04 DX20E3A Physical Properties 03/22/04 Factory Mutual Research 3009610 FM 4450 10/15/01 2D5A9.AM FM 4450 06/22/99 3014751 FM 4450 08/12/03 �014692 FM 4450 08/05/03 3012321 FM 4450 07/29/02 �008869 FM 4470 03/19/01 '037127 FM 4470 01/11/10 3039046 FM 4470 06/15/10 3048520 FM 4470 09/19/13 025766 FM 4470 11/13/06 Trinity ERD 3518.12.03 TAS 114-F/G/I 12/01/03 C35119.12.03-Rl TAS 114-D/J & TAS 117(B) 04/15/11 0351�5.07.03-1-RI TAS 1144 & TAS 117(B) 06/27/12 3§21.07.04 TAS 1144 & TAS 117(B) 07/28/04 3522.07.04 TAS 114-D 07/28/04 C31410.06.10 ASTM D 5147/4798 06/03/10 C7290.01.08 ASTM D 4601/1970 01/16/08 C8370.08.08-R1 TAS 114-1-1/J & TAS 117(B) 10/05/09 C8500SC.11.07 Rl ASTM D 6862/TAS 117(B) 08/07/09 C310310.12.09 TAS 114 / TAS 117 12/17/09 C10080.09.08-R4 ASTM D 5147/6163/6.164 03/25/10 1 ASTM D 6222/3909 C10080.09.10-R1 ASTM D 5147 & 6163 11/18/10 60560.06.10 TAS 114/TAS 117 06/10/10 C32830.07.10 FM 4470 / TAS 114 07/20/10 62970.09.10 ASTM D 6163 09/16/10 3513.08.02-R1 TAS 114/TAS 117 03/17/11 C32970.04.11 ASTM D 6164 04/01/11 C35500.02.11 TAS 117(B) 02/09/11 C35460.05.11 ASTM D1876 06/16/11 C45620.03.14 ASTM D1876, TAS 114 (H), 03/27/14 FM 4474 C47350.50.14 FM 4470 05/22/14 C44580.07.13 ASTM D 1876, 07/25/13 TAS 114, FM 4474 C42110.0.8.12 TAS 114 & TAS 117 08/13/12 PRI Construction Materials CTC-634-02-01 REV ASTM D 6163 11/24/08 Technologies CTC-032-02-01 ASTM D6163 01/22/08 CTC-066-02-01 ASTM D6163 08/09/11 CTC-070-02-01 ASTM D6222 08/09/11 NOA No.: 15-0622.21 CMAMM1-DADMECO=UNTY Expiration Date: 04/13/20 Approval Date: 08/20/15 Page 6 of 19 EVIDENCE SUBMITTED: Test Agency Test Identifier Description i CTC-093-02-01 ASTM D6164/4798 CT6122-02-01 ASTM D2178 CTC-123-02-01 ASTM D2178 CTC-127-02-01 ASTM D4601 CTC-128-02-01 ASTM D6163 CTC-129-02-01 ASTM D6163 CTC-132-02-01 ASTM D6164 CTC-162-02-01 ASTM D6164 CT6-161-02-01 ASTM D6164 CT6-183-02-01 ASTM D6162 CTC-190-02-01 ASTM D6164 CT6-199-02-01 ASTM D1970 I MIA MI DARE COUNTY Date 08/09/11 03/13/12 03/13/12 03/13/12 06/11/12 06/11/12 06/11/12 05/09/13 05/09/13 10/02/13 12/02/13 01/22/14 NOA No.: 15-0622.21 Expiration Date: 04/13/20 Approval Date: 08/20/15 Page 7 of 19 Membrane Type: SBS MODIFIED, SIELF-ADHERING Deck Type 1: Wood, Non -insulated Deck Description: Minimum 19/32" thick plywood attached using 8d ring shank nails spaced 6"o.c. at wood joists spaced maximum 24" o.c. System Type E(2): Base sheet mechanically fastened. All General and System Limitations apply. Separation Sheet: One ply of G1asBasa, Base Sheet, loose laid. (Optional) Base Sheet: One or more layers of Flintlastic SA Nai1B_ase, mechanically attached as described below. Fastening: Fastened with FBC HVHZ nails and tin caps spaced 6" o.c. at the 3" lap and 6" o.c. in four, equally spaced staggered center rows. SA P1yBase or Flintlastic SA Mid Ply, -adhered. Ply Sheet: One or more layersfof Flintlastic self (Optional) Membrane: One layer%of-Flintlastic-SA, Cap,_Flintlastic SA Cap CoolStar, Flintlastic SA Cap FR or Flintlastic SA Cap FR CoolStar, self -adhered. Surfacing: Any of the approved surfacing/coating options listed in Table 4. (Optional) Maximum Design -52.5 psf (See Gene�ul Limitation #7.) Pressure: NOA No.: 15-0622.21 Expiration Date: 04/13/20 Approval Date: 08/20/15 Page 13 of 19 WOOD DECK SYSTEM UwTATIONS: 1. A slip sheet is required with Ply 4 and Ply 6 when used as a mechanically fastened base or anchor sheet. GENERAL LBUTATIONS: 1. Fire classification is not part of this acceptance; refer to a current Approved Roofing Materials Directory for fire ratings of this product. 2. Insulation may be installed in multiple lay rs. The first layer shall be attached in compliance with Product Control Approval guidelines. All other layers shall be adhered in a full mopping of approved asphalt applied within the EVT range and at a rate of 20-40 lbs./sq., or mechanically attached using the fastening pattern of the top layer 3. All standard panel sizes are acceptable fo1r mechanical attachment. When applied in approved asphalt, panel size shall be 4' x 4' maximum. 4. An overlay and/or recovery board insulation panel is required on all applications over closed cell foam insulations when the base sheet is fully mopped. If no recovery board is used the base sheet shall be applied using spot mopping with approved asphalt, 121' diameter circles, 24" o.c.; or strip mopped 8" ribbons in three rows, one at each,sidelap and one down the center of the sheet allowing a continuous area of ventilation. Encircling of the strips is not acceptable. A 6" break shall be placed every 12' in each ribbon to allow cross ventilation. Asphalt application of either system shall be at a minimum rate 9f 12 lbs./sq. 5. Fastener spacing for insulation attachment is bused on a Minimum Characteristic Force (F') value of 275 lbf., as tested in compliance with Testing Application Standard TAS 105. If the fastener value, as field-tested, are below 275 lbf. insulation attachment shall not bel acceptable. 6. Fastener spacing for mechanical attachment of anchor/base sheet or membrane attachment is based on a minimum fastener resistance value in conjunction with the maximum design value listed within a specific system. Should the fastener resistance be less than that required, as determined by the Building Official, a revised fastener spacing, prepared, signed and sealed by a Florida registered Professional Engineer, Registered Architect, or Registered Roof Consultant may be submitted. Said revised fastener spacing shall utilize the withdrawal resistance value taken from Testing Application Standards TAS 105 and calculations in compliance with Roofing Application Standard RAS 117. 7. Perimeter and corner areas shall comply with the enhanced uplift pressure requirements of these areas. Fastener densities shall be increased for both insulation and base sheet as calculated in compliance with Roofing Application Standard RAS 117. Calculations prepared, signed and sealed by a Florida registered Professional Engineer, Registered Architect, or Registered Roof Consultant (When this limitation is specifically referred within this NOA, General Limitation #9 will not be applicable.) 8. All attachment and sizing of perimeter nailers, metal profile, and/or flashing termination designs shall conform with Roofing Application Standard RAS 111 and applicable wind load requirements. 9. The maximum designed pressure limitation listed shall be applicable to all roof pressure zones (i.e. field, perimeters, and comers). Neither rational 'analysis, nor extrapolation shall be permitted for enhanced fastening at enhanced pressure zones (i.e. perimeters, extended corners and corners). (When this limitation is specifically referred within this NOA, General Limitation #7 will not be applicable.) 10. All products listed herein shall have a quality assurance audit in accordance with the Florida Building Code and Rule 61 G20-3 of the Florida Administrative Code. END OF THIS ACCEPTANCE NOA No.: 15-0622.21 Expiration Date: 04/13/20 Approval Date: 08/20/15 Page 19 of 19