HomeMy WebLinkAboutEVALUATION REPORTQOTRINITYIERD EVALUATION REPORT -TI R O O F T I L E. SCANNEU RECEIVED APR 18 2018 ST. Lucie County, Permitting Entegra Roof Tile, LLC 1289 NE 9th Avenue Okeechobee, FL 34972 (602)515-6933 EXTERIOR RESEARCH & DESIGN, LLC. Certificate of Authorization #9503 353 CHRISTIAN STREET, UNIT #13 OXFORD, CT 06478 (203) 262-9245 Evaluation Report E39310.11.11-1-R4 FL7804-R10 Date of Issuance:11/02/2011 Revision 4:10/17/2017 SCOPE: This Evaluation Report is issued under Rule 61G20 3 and the applicable rules and regulations governing the use of construction materials in the State of Florida: The documentation submitted has been reviewed by Robert Nieminen, P.E. for use of the 'product under the Florida Building Code and Florida Building Code, Residential Volume. The products described herein have been evaluated for compliance with the 6th Edition (2017) Florida Building Code (HVHZ) sections noted herein. DESCRIPTION, Entegra Concrete Roof Tiles (HVHZljurisdictions) LABELING: Labeling shall be in accordance with ;the requirements the Accredited Quality Assurance Agency noted herein. I CONTINUED COMPLIANCE: This Evaluation Report is valid until such time as the named products) changes, the referenced Quality Assurance documentation chlanges, or provisions of the Code that relate to the product change. Acceptance of this Evaluation Report by the namied client constitutes agreement to notify Robert Nieminen, P.E. if the product changes or the referenced Quality Assurance documentation changes.. Trinity IERD requires a complete review of this Evaluation Report relative to updateclZode requirements with each Code Cycle. ADVERTISEMENT: The Evaluation Report number preceded by the words "TrinitylERD Evaluated" may be displayed in advertising literature. If any portion of the Evaluation Report is displayed, then it shall be done in its entirety. INSPECTION: Upon request, a copy of this entire Evaluation Report shall be provided -to the user bythe manufacturer or its distributors and shall be available for inspection at the job site at the request of the Building Official. This Evaluation Report consists of pages 1 through 8. i. Prepared by: Robert J.M. Nieminen, P.E. Florida Registration No. 59166, Florida DCA ANE1983 The facsimile seal appearing was authorized by Robert Nleminen, P.E. on 10/17/2017. This does not serve as an electronically signed document. Signed, sealed hardcoples have been transmitted to the Product Approval Administrator and to the named client CERTIFICATION OF INDEPENDENCE: 1. TrinitylERD does not have, nor does it intend to acquire or will it acquire, a financial interest in any company manufacturing or distributing products it evaluates. 2. Trinityl ERD is not owned, operated or controlled by any company manufacturing or distributing products it evaluates. 3. Robert Nieminen, P.E. does not have nor will acquire, a financial interest in any company manufacturing or distributing products for which the evaluation reports are being issued. 4, Robert Nieminen, P.E. does not have, nor will acquire, a financial interest in any other entity involved in the approval process of the product. 5. This is a building code evaluation. Neither Trinity lERD nor Robert Nieminen, P.E. are, in any way, the Designer of Record for any project on which this Evaluation Report, or previous versions thereof, is/was used for permitting or design guidance unless retained specifically for that purpose. FILE COPY • '111 P Q0TRINITYIERD ROOFING SYSTEM EVALUATION: 1. SCOPE: Product Category: hoofing Sub -Category: Roofing Tiles Compliance Statement: Entegra Concrete Roof Tiles, as produced by Entegra Roof Tile, LLC, have demonstrated compliance with the following sections of the Florida Building Code through testing in accordance with the following Standards. Compliance is subject to the Installation Requirements and Limitations / Conditions of Use set forth herein. 2. STANDARDS: Section 1523.6.5.2 1523.6.5.2 1523.6.5.2.2 1523.6.5.2.3 1523.6.5.2.3 3. REFERENCES: Entit ERD (TST6049) ATL(TST3782) ATL(TST3782) ATL(TST3782) ATL(TST3782) ATL (TST 3782) ATL (TST 3782) ATL (TST 3782) ATL (TST 3782) ATL (TST 3782) Miami -Dade (CER1592) Miami -Dade ,(CER1592) Miami -Dade (CER1592) Miami -Dade (CER1592) Miami -Dade (CER1592) Tile Roof Institute PRI (QUA9110) Physical Properties Wind Driven Rain Static Uplift Resistance Static Uplift Resistance Static Uplift Resistance TAS 101 Physical Properties Physical Properties Physical Properties Physical Properties Physical Properties Physical Properties Physical Properties Physical Properties Physical Properties HVHZ Compli HVHZ Compli HVHZ Compli HVHZ Compli HVHZ Compli TAS 100, TAS Quality Assur 102, 102(A) Standard TAS 112 TAS 100 TAS 101 TAS 102 TAS 102(A) Reference P39740.02.12 RT0624.05-14 RT0624.04-14 RT1210.02-15 RT1210.03-15 RT1103.01-15 RT1103.02-15 RT1103.03-15 RT1103.04-15 RT1103.05-15 14=0416.12 15-0721.04 16-0112.06 16-0112.07 16-0112.08 Membership Confirmation Service Confirmation Year 1995 1995 1995 1995 1995 Date 02/21/2012 07/03/2014, 07/07/2014 12/17/2015 12/17/2015 11/07/2015 11/07/2015 11/07/2015 11/07/2015 11/07/2015 11/27/2014 11/05/2015 02/25/2016 02/25/2016 02/25/2016 Current Exp.11/02/2018 Exterior Research and Design, LLC. I Evaluation Report E39330.11.11-1-R4 Certificate ojAuthoriration #9503 6EDITION (2017) FBC HVHZ EVALUATION FL7804-R10 Entegra Roof Tiles Revision 4:10/17/2017 Page 2 of 8 ��NI"jY I ERD 4. PRODUCT DESCRIPTION: 4.1 1 TAS 112, Type 3a (flat -profile) BERMUDA FLAT, PLANTATION FLAT and HORIZON FLAT Bermuda Flat Exterior Research and Design, I.I.C. Certificate of Authorization #9503 <13"17-1/4" Horizon Flat 6' EDITION (2017) FBC HVHZ EVALUATION Entegra Roof Tiles Plantation Flat Evaluation Report E39330.11.11-1-R4 FL7804-R10 Revision 4: 10/17/2017 Page 3 of 8 4.2 1, TM 112, Type 11 4.3 I' TAS 112, Type'1b Nail Holes T� \ Ir. , Estate "S" 4.3 ' TAS 112, Type 2a (nc 17" Galena Spanish "S"� TRINITY I ERD -profile) BELLA HIGH "S" , Bella High "S" ng, high -profile).' I GALENA'SPANISH "S" and REGAL 10" Regal Exterior Research and Design, I.I.C. I Evaluation Report E39310.11.11-1-R4 Certificate ojAuthorization #9503 I6T" EDITION (2017) FBC HVHZ EVALUATION FL7804-R30 Entegra Roof Tiles Revision 4:10/17/2017 Page 4 of 8 I \l TRINITYIERD S. LIMITATIONS: 5.1 This is a building code evaluation. Neither Trinity]ERD nor Robert Nieminen, P.E. are, in any way, the Designer of Record for any project on which this Evaluation Report, or previous versions thereof, is/was used for permitting or design guidance unless retained specifically for that purpose. 5.2 This Evaluation Report is for use in FBC HVHZ jurisdictions or others adopting FBC HVHZ requirements. 5.3 Fire classification is not part of this evaluation; refer to FBC 1516 or listing by an approved testing agency for fire rating of this product. 5.4 Reference is made to FBC 1512.4.2.4 regarding field testing of completed tile roof installations. 5.5 Applicant shall retain the services of an FBC listed, accredited laboratory to perform quarterly tests in accordance with TAS 112, Appendix W. 5.6 Minimum underlayment shall comply with the RAS 118, RAS 119 or RAS 120, as applicable. Llnderlayrhient products shall hold current Florida Statewide Product Approval or Local Approval for use in tile roof assemblies in FBC HVHZ jurisdictions. 5.7 Minimum roof deck requirements shall be in accordance with applicable FBC HVHZ requirements. 5.8 All products in the roof assembly shall have quality assurance audit in accordance with the F.A.C. Rule 61G20-3. 6. INSTALLATION: 6.1 Entegra Concrete Roof Tiles may be mechanically fastened, mortar -set or adhesive -set. Installation shall comply with manufacturer's current published instructions, but not less than the requirements of RAS 118, RAS 119 or RAS 120, as applicable. I . 6.2 Attachment Calculations: Entegra Concrete Roof Tile shall be evaluated as a 'Moment -Based System' in accordance with Roofing Application Standard RAS 127-11 using the data outlined herein. TABLE 1: AERODYNAMIC MULTIPLIERS -%1 (FT3) Tile Batten Application Direct -Deck Application Bermuda Flat 0.189 0.205 Plantation Flat 0.267 0.289 Horizon Flat 0.305 0.330 Bella High "S" 1 0.349 0.378 Estate "S" 0.267 0.289 Hacienda 0.267 0.289 Galena Spanish "S" N/A 0.235 Regal 0.287 0.311 TABLE 2: RESTORING MOMENT DUE TO GRAVITY - M, (FT-LBF) Roof Slope (0) Tile 2:12<0<3:12 3:12<0<4:12 4:1250<5:12 5:12<0<6:12 6:12<0<7:12 0>7:12 Battens Direct Battens Direct Battens Direct Battens Direct Battens Direct Battens Direct Bermuda Flat 5.22 6.43 5.17 6.37 5.09 , 6.27 4.98 6.15 4.86 6.00 4.72 5.83 Plantation Flat 7.22 7.91 6.85 7.79 6.75 7.67 6.61 7.52 6.44 . 7.32 6.26 7.04 Horizon 7.60 8.32 7.52 8.24 7.41 8.12 7.26 7.95 7.09 7.76 6.89 7.55 Bella High "S" 6.19 6.89 6.11 6.80 5.99 6.67 5.85 6.51 5.68 6.33 5.50 6.13 Estate "S" 6.14 6.84 5.91 6.74 5.82 6.64 5.70 6.50 5.56 6.33 5.40 6.14 Hacienda 5.92 6.80 5.92 6.80 5.82 6.69 5.70 6.55 5.56 6.39 5.41 6.22 Galena Spanish "S" N/A 6.20 N/A 6.13 N/A 6.03 N/A 5.89 N/A 5.74 N/A 5.57 Regal 7.77 8.34 7.77 8.34 7.65 8.20 7.49 8.03 7.30 7.83 7.10 7.61 Exterior Research and Design, I.I.C. Evaluation Report E39310.11.11-1-R4 Certificate ofAuthorization 89503 a EDITION(2617) FBC HVHZ EVALUATION " ' FL7804-R10 Entegra Roof Tiles Revision 4:10/17/2017, Page 5 of 8 QOTRINITYIERD TABLE JA: ATTACHMENT RESISTANCE EXPRESSED AS A MOMENT- MF (FT-LBF), MECHANICALLY ATTACHED SYSTEMS Tile Fastener Direct -Deck (min.15/32" plywood) Direct -Deck (min.19/32" plywood) Battens Type # Size Shank . Clip Nail One (1) lod Smooth or Screw N/A 7.3 9.8 4.9 Nail lTwo (2) 10d Smooth or Screw N/A 14.0 18.8 7.4 Nail 'One (1) 10d Smooth or Screw Eave 19.0 19.0 22.1 Nail One (1) 10d Smooth or Screw Field 24.3 24.3 24.2 Bermuda Flat, Nail Two (2) lod Smooth or Screw Eave 31.9 31.9 32.2 Plantation Flat or Nail Two (2) 10d Smooth or Screw Field 35.5 35.5 34.8 Horizon Nail Two (2) 10d Ring N/A 30.9 38.1 17.2 Nail' Two (2)' 10d' Ring' N/A .50.31 65.51 48.31 Screw One (1) #8 N/A N/A 30.8 30.8 18.2 Screw Two (2) #8 N/A N/A 51.7 51.7 24.4 ' Installation with a �-inch tile headiap and fasteners located min. 2Y22-inch from head of tile. Nail One(1)2 10d Smooth or Screw N/A 8.82 11.82 4.12 Nail Two (2) lod Smooth or Screw N/A 16.4 21.9 7.1 Nail One(1)2 lod Smooth or Screw Eave 19.02 19.02 22.12 Nail Or?e(1)2 10d Smooth or Screw Field 24.32 24.3' 24.22 Nail Ttiyo (2) 10d Smooth or Screw Eave 31.9 31.9 32.2 "S" Nail Two (2) lod Smooth or Screw Field 35.5 35.5 34.8 Estate or Hacienda Nail Two (2) 10d Ring N/A 27.8 37.4 28.8 Nail' Two (2)1 10d' Ring' N/A 43.01 67.51 50.9, Screw One' (1)' #8 N/A N/A 25.82 25.82 22.9' Screw Two (2) #8 N/A N/A 47.1 47.1 49.1 'Installation with a 4-inch tile headlap and fasteners located min. 2Y2-inch from head of tile. 2 For one (1) fastener installations, utilize hole that is approximately 4%-inch from the interlocking edge. Nail One (1) lod Smooth or Screw N/A 5,1 6.8 2.8 Nail Twol(2) 10d Smooth or Screw N/A 6.9 9.2 7.3 Nail Onel(1) 10d Smooth or Screw Field 23.1 23.1 19.0 Nail One '(1) 10d Smooth or Screw Eave 29.3 29.3 24.0 Nail Two 1(2) 10d Smooth or Screw Field 27.6 27.6 38.6 Bella High "S", Galena Spanish "S" or Regal Nail Two J2) 10d Smooth or Screw Eave 38.1 38.1 41.8 Nail Two,2) 10d Ring N/A 28.6 41.2 19.4 Nail' Two JQ)' 10d' Ring' N/A 33.1' 48.1' 50.9' Screw One O #8 N/A. N/A 20.7 20.7 18.1 Screw Two (P) #8 N/A N/A 43.2 43.2 29.8 1Installation with a 4-inch tile headlap and fasteners located min. 2Y.-inch from head of tile. Exterior Research and Design, I.I.C. I Evaluation Report E39310.11.11-1-R4 Certificate of Authorization #9503 iTM EDITION (2017) FBC HVHZ EVALUATION FL7804-R10 Entegra Roof Tiles Revision 4:10/17/2017 Page 6 of 8 V 1 �NIN I ERD TABLE 4: ,ATTACHMENT RESISTANCE EXPRESSED AS A MOMENT— MF (FT-LBF)' MORTAR AND ADHESIVE -SET SYSTEMS i Note from Entegra Roof Tile, LLC.: The performance data listed�in Table 4 are based on the respective adhesive manufacturers' test reports and Miami -Dade NOAs. Entegra Roof Tile, LLC. relies upon the adhesive manufacturers to provide these values for our inclusion in this FBC HVHZ Evaluation Report. Please consult the individual adhesive manufacturer for information on product approvals, limitations, revisions or other information for determining wind load and overturning moment performance. Tile Adhesive Tile Product Product Approval Placement Mf (ft-lbf) "TILE BOND'" by Dow Chemical NOA 16-0222.01 Interdependent (2-paddy) 41 Bermuda "Touch N' Seal Storm Bond" by DAP Foam NOA 16-0421.03 Interdependent (2-paddy) 73 Flat, Plantation "Polyset® RTA-1" by ICP Adhesives & Sealants NOA 16-0315.03 Interdependent (2-paddy) 52 Flat or Horizon "Polyset® AH-160" by ICP Adhesives & Sealants `:I I NOA 17-0322.03 Interdependent(2-paddy) 43 Independent (medium paddy, -30 g) 51 Independent (large paddy, -45 g) 92 "TILE BOND'"" by Dow Chemical NOA 16-0222.01 Interdependent (2-paddy) 44 "Touch N' Seal Storm Bond" by DAP Foam NOA 16-0421.03 Interdependent (2-paddy) 42 "S" "Polyset® RTA-1" by ICP Adhesives & Sealants NOA 16-0315.03 Interdependent (2-paddy) 44 Estate or Hacienda "Polyset® AH-160" by ICP Adhesives & Sealants NOA 17-0322.03 Interdependent(2-paddy) 50 Independent (medium paddy, -30 g) 37 Independent (large paddy, -54 g) 61 Mortar Various Per RAS 120 21 "TILE BOND'""' by Dow Chemical INOA 16-0222.01 Interdependent (2-paddy) 48 'Touch N' Seal Storm Bond" by DAP Foam NOA 16-0421.03' Interdependent (2-paddy) 52 Bella High "S", "Polyset® RTA-1" by ICP Adhesives & Sealants !NOA 16-0315.03 Interdependent (2-paddy) 36 Galena „ „ Spanish S or Regal "Polyset® AH-160" by ICP Adhesives & Sealants , NOA 17-0322.03 Interdependent(2-paddy) 30 Independent (medium paddy, -30 g) 491 Independent (large paddy, n,63 g) 94 Mortar Various Per RAS 120 25 7. LABELING: 7.1 Each unit shall bear the imprint and/or identifiable marking of the manufacturer's name or logo, as detailed below. Tile lots shall be labeled in accordance with the requirements of the Accredited Quality Assurance Agency noted herein. 27 ENTEGRR Labeling: Bermuda Flat, Plantation Flat, Estate "S", Bella High "S", Galena Spanish "S" Exterior Research and Design, I.I.C. Evaluation Report E39310.11.11-1-R4 certificate ofAuthorization #9503 6' EDITION (2017) FBC HVHZ EVALUATION FL7804-R10 Entegra Roof Tiles Revision 4: 10/17/2017 Page 7 of 8 a' , I 8. BUILDING PERMIT REQUIREN As required by the Building this product. 9. MANUFACTURING PLANTS: \l I �NITi I ERD and/or anson Labeling: Horizon Flat, Hacienda, Regal I or Authority Having Jurisdiction in order to properly evaluate the installation of P Plant , : P rof iles Okeechobee, FL Bermuda Flat, Plantation Flat, Estate "S", Bella High "S", Galena Spanish "S" Ft. Myers, FL Horizon Flat, Hacienda Deerfield Beach, FL Horizon Flat, Hacienda, Regal 10. QUALITY ASSURANCE ENTITY: PRI Construction Materials T Exterior Research and Design, LLC. Certificate of Authorization #9503 s, LLC. — QUA9110; (813) 621-5777 - END OF EVALUATION REPORT — Evaluation Report E39310.11.11.1-R4 6n' EDITION (2017) FBC HVHZ EVALUATION FL7804=R10 Entegra Roof Tiles Revision 4: 10/17/2017 Page 8 of 8