DEPARTMENT OF REGULATORY AND ECONOMIC RESOURCES (RER)
BOARD AND CODE ADM IN ISTRATI ON DIVISION
NOTICE OF ACCEPTANCE (N
J
Boral Roofing LLC,
7575 Irvine Center Drive, Suite 100
I r v In., CA 92618
MIAMI-DADE COUNTY
PRODUCT CONTROL SECTION
11805 SW 26 Street, Room 208
Miami, Florida 33175-2474
T (786) 315-2590 F (786) 315-2599
---. m ie mid a d..no /Bco n—Y
SCOPE:
This NOA is being issued under the applicable rules and regulations governing the use of construction materials. The
documentation submitted has been reviewed and accepted by Miami -Dade County RER - Product Control Section to be
used in Miami Dade County and other areas where allowed by the Authority Having Jurisdiction (AHJ).
This NOA shall not be valid after the expiration date) stated below. The Miami -Dade County Product Control Section
(In Miami Dade County) and/or the AHJ (in areas other than Miami Dade County) reserve the right to have this
product or material tested for quality assurance purpbses. If this product or material fails to perform in the accepted
manner, the manufacturer will incur the expense of such testing and the AHJ•may immediately revoke, modify, or
suspend the use of such product or material within their jurisdiction. RER reserves the right to revoke this acceptance,
if it is determined by'Miami-Dade County Product Control Section that this product or material fails to meet the
requirements of the applicable building code.
This product is approved as described herein, and has been designed to comply with the Florida Building Code
including the High Velocity Hurricane Zone of the lorida Building Code.
DESCRIPTION: BORALTIieSeal
LABELING: Each unit shall bear a permanent label with the manufacturer's name or logo, city, state and following
statement: "Miami -Dade County Product Control Approved", unless otherwise noted herein.
R E N EWAL of this NOA shall be considered after,' a renewal application has been filed and there has been no change
in the applicable building code negatively affecting the performance of this product.
T E RM I NAT 10 N of this NOA will occur after the expiration date or if there has been a revision or change in the
materials, use, and/or manufacture of the product or process. Misuse of this NOA as an endorsement of any product,
for sales, advertising or any other purposes shall automatically terminate this NOA. Failure to comply with any section
of this NOA shall be cause for termination and removal of NOA.
ADVERTISEMENT: The NOA number preceded by the words Miami -Dade County, Florida, and followed
by the expiration date may be displayed in advertising literature. If any portion of the NOA is displayed, then
it shall be done in its entirety.
INSPECTION: A copy of this entire NOA shall be provided to the user by the manufacturer or its distributors and
shall be available for inspection at the job site at the request of the Building Official.
This renewes NOA#13-1113.05 and consists of pages I through 4.
The submitted documentation was reviewed by Freddy Se m i n o
NOA No.: 17-0530.10
MIAMI•DADECOUNW Expiration Date: 07/31/18
Approval Date: 07/27/17
FILE COPY Page 1 of 4
ROOF ING COMPONENT APPROVAL
Category: Roofing
Sub -Category: Underlayment
Material: SBS
PRODUCTS DESCRIPTION;
C est
Product Dimensions Specification
BORAL TileSeal 36" x 36' rolls TAS 103
36" x 72' rolls ASTM D 1970
MANUFACTURING LOCATION;
1. Brentwood, NH
EVIDENCE SUBMITTED;
Test Agency
Underwriters Laboratories, Inc.
IRT-Arcon, Inc.
PRI Asphalt Technologies, Inc.
PRI Asphalt Technologies, Inc.
PRI Construction Materials
Technologies, LLC.
Product
Description
SBS self -adhering asphalt sheet material with a
white glass re -enforced polyester surfacing fabric;
for use as an underlayment in sloped roof
assemblies.
Test I dentlfier
Test Name/Report
Date
R14610
Follow up Service
03/28/02
02-012
i
TAS 103
02/28/02
NEI-006-02-01
TAS 103
04/01/02
I
NEI-008-02-01
TAS 114 (H)
07/30/02
NEI-045-02-01
ASTM D 4798 & ASTM G 155
08/08/07
NEI-053-02-61
ASTM D 4798 & ASTM G 155
05/01/08
NEI-076-02-01
TAS 103 / ASTM D4798
02/14/11
NEI-034-02-;02
I
ASTM D 1970
01/29/13
NOA No.: 17-0530.10
QM1AM1-DMAEC=0Expiration Data: 07/31/18
Approval Date. 07/27/17
Page 2 of 4
APPROVED ASSEMBLIES;
Deck Type 1: Wood, non -insulated
Deck Description: "/32" or greater plywood or world plank
System E (1) : Anchor sheet mechanically fastened deck, membrane adhered.
Base Sheet: One or more plies of ASTM D 226 Type H or ASTM D 2626 with a minimum 4" head lap and a
6" end lap mechanically fastened to deck with approved nails and tin caps 6" o.c. at the laps and
two staggered rows 12" o.c. the field of the roll.
M e m b r a n a: One or more plies of BORAL TileSeal Underlayment with a minimum 3" head lap and minimum
6" end lap. Place the first course of membrane parallel to the eave, rolling the membrane to
obtain maximum contact. Remove the release membrane as the membrane is applied. Vertical
strapping of the roof with BORAL TileSeal Underlayment is acceptable. All end laps and laps
without black selvage area shall be sealed under lap using an SBS modified mastic.
Note : When used in Tile roof systems BORAL TileSeal Underlayment shall be back nailed to
deck with approved annular ring shank nails and tin caps at a maximum 6" o.c. at the side laps.
No nails or tin caps shall be exposed.
Surfacing: Approved for Approved Adhesive Set Roof Tile Systems, Mechanically Fastened Roof Tile,
Metal Roofing, Wood Shake & Shingles, and Asphaltic Shingle assemblies.
NOA No.: 17-0530.10
Expiration Date: 07/31/18
Approval Date: 07/27/17
Page 3 of 4
i
LIMITATIONS;
1. Fire classification is not part of this acceptance.
2. This acceptance is for prepared roofing applications. Minimum deck requirements shall be in compliance with
applicable building code. BORAL TileSeal underlayment shall be installed in strict compliance with applicable
Building Code.
3. BORAL TileSeal underlayment shall be applied to� a smooth, clean and dry surface with deck free of irregularities.
4. BORAL TileSeal underlayment shall not be applied over an existing roof membrane as a recover, but may be
applied over a roofing Base/Anchor sheet underlayment.
5. BORAL TileSeal underlayment shall not be left exposed as a temporary roof for longer than 180 days of
application.
6. The standard maximum roof pitch for BORAL TileSeal underlayment shall be 6:12 when tiles are loaded directly
to the BORAL TileSeal underlayment; loading boards or battens are required on roof pitches greater than 6:12".
7. Refer to Prepared Roofing system Product Control Notice of Acceptance for listed approval of this product with
specific prepared roofing products.
8. Tiles shall be stored on battens on roof pitches grlater than 6:12".
9. BORAL TileSeal underlayment may be used �''ith any approved roof covering Notice of Acceptance listing
BORAL TileSeal underlayment as a component I part of an assembly in the Notice of Acceptance. If BORAL
TileSeal underlayment is not listed, a request may be made to the Authority Having Jurisdiction (AHJ) or the
Miami -Dade County Product Control Department for approval provided that appropriate documentation is
provided to detail compatibility of the products, wind uplift resistance, and fire testing results.
10. All nails in the deck shall be carefully checked for protruding heads. Re -fasten any loose decking panels. Sweep
the deck thoroughly to remove any dust and debris prior to application.
11. When applying the membrane in the valley, start at the low point and work to the high point, rolling the membrane
from the center outward in both directions. For fidge applications, center the membrane and roll from the center
outward in both directions.
12. Roll or broom the entire membrane surface so as io have 100% contact with the surface, giving special attention to
overlap areas.
13. Flash vent pipes, stacks, chimneys and penetrations in compliance with Roof Assembly current Product Control
Notice of Acceptance and applicable Building Code.
14. All protrusions or drains shall be initially taped with a 6" piece of underlayment. This target piece shall be pressed
in place and formed around the protrusion to ensure a tight fit. A second layer of BORAL TileSeal underlayment
shall be applied over the underlayment, and sealed using an SBS modified mastic.
15. All products listed herein shall have a quality assurance audit in accordance with the Florida Building Code and
Rule 61 G20-3 of the Florida Administrative Code.
16. All membranes or packaging shall bear the imprint or identifiable marking of the manufacturer's name or logo, city
and state of manufacturing facility, and the following statement: "Miami -Dade County Product Control Approved"