HomeMy WebLinkAboutENERGY EFFICIENCY CODE & PROJECT INFORMATIONi SGANN DIV FORM R405-2017 i FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION Florida Department of Business and Professional Regulation - Residential Performance Method Project Name: PARENT RESIDENCE Builder Name: MEL- RY CONSTRUCTION Street: 2044 NETTLES BLVD. Permit Office: ST LUCIE COUNTY City, State, Zip: JENSEN BEACH, FL, 34957 Permit Number: 1804-0648 Owner: Jurisdiction: ST LUCIE COUNTY Design Location: FL, Fort Pierce County:: St. Lucie (Florida Climate Zone 2 ) 1. New construction or existing New (From Plans) 9. Wall Types (1696.0 sqft.) Insulation Area 2. Single family or multiple family Single-family a. Concrete Block - Ext Insul, Exterior R=4.1 1158.70 ft2 b. Frame - Wood, Exterior R=19.0 377.33 ft2 3. Number of units, if multiple family 1 c. Frame - Wood, Exterior R=11.0 160.00 ft2 4..Number of Bedrooms 2 d. N/A R= ft2 10. Ceiling Types (1196.0 sgft.) Insulation Area 5. Is this a worst case? No a. Under Attic (Vented) R=30.0 1196.00 ft2 6. Conditioned floor area above grade (ft2) 1196 b. N/A R= ft2 Conditioned floor area below grade (ft2) 0 c. N/A R= ft2 11. Ducts R ft2 7. Windows(209.7 sgft.) Description Area a. Sup: Attic, Ret: Attic, AH: CLOSET 6 120 a. U-Factor: Sgl, U=0.65 143.00 ft2 SHGC: SHGC=0.25 b. U-Factor: Sgl, U=0.70 66.67 ft2 12. Cooling systems kBtu/hr Efficiency SHGC: SHGC=0.30 a. Central Unit 24.0 SEER:16.00 c. U-Factor: N/A ft2 SHGC: 13. Heating systems kBtu/hr Efficiency d. U-Factor: N/A ft2 a. Electric Strip Heat 17.6 COP:1.00 SHGC: Area Weighted Average Overhang Depth: 1.000 ft. Area Weighted Average SHGC: 0.266 14. Hot water systems a. Electric Tankless Cap: 1 gallons 8. Floor Types (1196.0 sgft.) Insulation Area EF: 0.980 a. Slab -On -Grade Edge Insulation R=0.0 1196.00 ft2 b. Conservation features b. N/A R= ft2 None c. N/A R= ft2 15. Credits None Total Proposed Modif ed Loads: 47.24 Glass/Floor Area: 0.175 PASS Total Baseline Loads: 47.84 . I hereby certify that the plans and specifications covered by Review of the plans and S7 4?� this calculation are in compliance with the Florida Energy specifications covered by this O�SkYE Code. calculation indicates compliance �'� �i„°'' �` ` with the Florida Energy Code.:.�` PREPA _ ED Y: Before construction is completed DATE: this building will be inspected for a I compliance with Section 553.908 I hereby certify that this building, as designed, is in compliance Florida Statutes.; Sit with the Florida Energy Code. I G'Ojrj'WE OWNER/AGENT- BUILDING OFFICIAL: DATE: I DATE: - Compliance requires certification by the air handler unit certified factory -sealed in accordance with R403.3.2.1. - Compliance requires an Air Barrier and Insulation Inspec an envelope leakage test report with envelope leakage no that the air handler enclosure qualifies as Checklist in accordance with R402.4.1.1 and this project requires ter than 7.00 ACH50 (11402.4.1.2). File C()v 5/22/2018 11:46 AM EnergyGauge® USA - FlaResl 017 Section R405.4.1 Compliant Software I I I Page 1 of 6 FORM R405-2017 I PROJECT Title: PARENT RESIDENCE I Bedrooms: 1 2 Address Type: Street Address Building Type: User Conditioned Area: 1196 Lot # Owner Name: Total Stories: 1 Block/Subdivision: # of Units: 1 Worst Case: No PlatBook: Builder Name: MEL- RY CONSTRUCTION Rotate Angle: 0 Street: 2044 NETTLES BLVD. Permit Office: ST LUCIE COUNTY Cross Ventilation: No County: St. Lucie Jurisdiction: ST LUCIE COUNTY Whole House Fan: No City, State, Zip: JENSEN BEACH, Family Type: Single-family FL, 34957 New/Existing: New (From Plans) Comment: CLITATE Design Temp Int Design Temp Heating Design Daily Temp �/ Design Location TMY Site I97.5 % 2.5 % Winter Summer Degree Days Moisture Range FL, Fort Pierce FL VERO_BEACH_MUNI I 39 90 70 75 299 62 Low BLOCKS I Number Name Area Volume 1 Entire House 1196 9568 SPACES I Number Name Area Volume Kitchen Occupants Bedrooms InfilID Finished Cooled Heated 1 LAUNDRY 90 720 No 0 1 Yes Yes Yes 2 KITCHEN 240 1920 Yes 0 1 Yes Yes Yes 3 LIVING ROOM 182 1456 No 0 1 Yes Yes Yes 4 BATH 80 640 No 0 1 Yes Yes Yes 5 BEDROOM 162 1296 No 0 1 1 Yes Yes Yes 6 CLST 12 96 No 0 1 Yes Yes Yes 7 STAIRS 60 480 No 0 1 Yes Yes Yes 8 DEN 89 712 No 0 1 Yes Yes Yes 9 BATH 2 81 648 No 0 1 Yes Yes Yes 10 CLOSET 9 72 No 0 1 Yes Yes Yes 11 CLST 2 24 192 No 0 1 Yes Yes Yes 12 BEDROOM 2 167 1336 No, 0 1 1 Yes Yes Yes FLOORS I # Floor Type Space Perimeter Perimeter R-Value Area Joist R-Value Tile Wood Carpet 1 Slab -On -Grade Edge Insulation LAUNDRY 26.8 ft l 0 90 ft2 ---- 1 0 0 2 Slab -On -Grade Edge Insulation KITCHEN 35 ft 0 240 ft2 _--- 1 0 0 3 Slab -On -Grade Edge Insulation LIVING ROOM 14 ft 0 I 182 ft2 ---- 1 0 0 4 Slab -On -Grade Edge Insulation BATH 17 ft 0 80 ft2 ---- 1 0 0 5 Slab -On -Grade Edge Insulation i BEDROOM 34 ft 0 162 ft2 ---- 1 0 0 i I 5/22/2018 11:46 AM EnergyGauge® USA - FlaReg2017 Section R405.4.1 Compliant Software Page 2 of 6 I I i FORM R405-2017 FLOORS # Floor Type Space Perimeter Perimeter R-Value Area Joist R-Value Tile Wood Carpet 6 Slab -On -Grade Edge Insulation CLST 2 ft 0 12 ft2 ---- 1 0 0 7 Slab -On -Grade Edge Insulation STAIRS 19 ft I 0 60 ft2 ---- 1 0 0 8 Slab -On -Grade Edge Insulation DEN 18 ft 0 89 ft2 ---- 1 0 0 9 Slab -On -Grade Edge Insulation BATH 2 19 ft 0 81 ft2 ---- 1 0 0 10SIab-On-Grade Edge Insulation CLOSET 1 ft 0 9 ft2 ---- 1 0 0 11SIab-On-Grade Edge Insulation CLST 2 2 ft 0 24 ft2 ---- 1 0 0 12SIab-On-Grade Edge Insulation BEDROOM 2 25.1 ft 0 167 ft2 ---- 1 0 0 ROOF I Roof Gable Roof Solar SA Emitt Emitt Deck Pitch V # Type Materials Area Area Color Absor. Tested Tested Insul. (deg) 1 Hip Metal 1338 ft2 0 ft2 Light 0.6 No 0.9 No 0 26.6 ATTIC I / IRatio V # Type Ventilation Vent (1 in) Area RBS IRCC 1 Full attic Vented 1150 1196 ft2 N N CEILING I # Ceiling Type Space RValue Ins Type Area Framing Frac Truss Type 1 Under Attic (Vented) LAUNDRY 30 Blown 90 ft2 0.1 Wood 2 Under Attic (Vented) KITCHEN 30 Blown 240 ft2 0.1 Wood 3 Under Attic (Vented) LIVING ROOM 30 Blown 182ft2 0.1 Wood 4 Under Attic (Vented) BATH 30 Blown 80 ft2 0.1 Wood 5 Under Attic (Vented) BEDROOM 30 Blown 162ft2 0.1 Wood 6 Under Attic (Vented) CLST 30 Blown 12 ft2 0.1 Wood 7 Under Attic (Vented) STAIRS 30 Blown 60 ft2 0.1 Wood 8 Under Attic (Vented) DEN 30 130 Blown 89 ft2 0.1 Wood 9 Under Attic (Vented) BATH 2 Blown 81 ft2 0.1 Wood 10 Under Attic (Vented) CLOSET 30 Blown 9 ft2 0.1 Wood 11 Under Attic (Vented) CLST 2 30 Blown 24 ft2 0.1 Wood 12 Under Attic (Vented) BEDROOM 2 130 Blown 167 ft2 0.1 Wood WALLS I Adjacent Cavity Width Height Sheathing Framing Solar Below Space _ 1 N Exterior Concrete Block - Ext InsuILAUNDRY 4.I1 9 0 8 0 72.0 ft2 0 0 0.6 0 2 E Exterior Concrete Block - Ext InsuILAUNDRY 4.11 8 0 8 0 64.0 ft2 0 0 0.6 0 _ 3 SE Exterior Concrete Block- Ext InsuILAUNDRY 4!1 9 10 8 0 78.7 ft2 0 0 0.6 0 4 N Exterior Concrete Block - Ext Insul KITCHEN 4.!1 15 i 0 8 0 120.0 ft2 0 0 0.6 0 I I I I 5/22/2018 11:46 AM EnergyGauge® USA -1 I017 Section R405.4.1 Compliant Software Page 3 of 6 F(1RAA PAnF_7017 WALLS I Adjacent Cavity I Width Height Sheathing Framing Solar Below SpaceArea 5 SE Exterior Concrete Block- Ext Insul KITCHEN 4.1 17 0 8 0 136.0 ft2 0 0 0.6 0 6 W Exterior Frame -Wood KITCHEN 11 3 0 8 0. 24.0ft2 0 0 0.6 0 7 S Exterior Frame - Wood LIVING ROO 11 I 14 0 8 0 112.0 ft2 0 0 0.6 0 8 E Exterior Frame - Wood BATH 11 3 0 8 0 24.0 ft2 0 0 0.6 0 9 S Exterior Concrete Block - Ext Insul BATH 4.1 8 0 8 0 64.0 ft2 0 0 0.6 0 10 W Exterior Concrete Block - Ext Insul BATH 4.1 6 0 8 0 48.0 ft2 0 0 0.6 0 11 N Exterior Concrete Block - Ext InsuBEDROOM 4.1 13 0 8 0 104.0 ft2 0 0 0.6 0 12 S Exterior Concrete Block - Ext InsuBEDROOM 4.1 7 0 8 0 56.0 ft2 0 0 0.6 0 13 W Exterior Concrete Block - Ext InsuBEDROOM 4.1 14 0 8 0 112.0 ft2 0 0 0.6 0 14 N Exterior Concrete Block - Ext Insul CLST 4.1 2 0 8 0 16.0 ft2 0 0 0.6 0 15 N Exterior Concrete Block - Ext Insul STAIRS 4.1 15 0 8 0 120.0 ft2 0 0 0.6 0 16 E Exterior Frame - Wood STAIRS 19 4 0 8 0 32.0 ft2 0 0 0.6 0 17 N Exterior Concrete Block - Ext Insul DEN 4.1 7 0 8 0 56.0 ft2 0 0 0.6 0 18 W Exterior Frame - Wood DEN 19 11 0 8 0 88.0 ft2 0 0 0.6 0 19 S Exterior Concrete Block - Ext Insul BATH 2 4.1 5 0 8 0 40.0 ft2 0 0 0.6 0 20 W Exterior Concrete Block - Ext Insul BATH 2 4.1 9 0 8 0 72.0 ft2 0 0 0.6 0 21 E Exterior Frame - Wood CLST 2 19 2 0 8 0 16.0 ft2 0 0 0.6 0 22 E Exterior Frame - Wood BEDROOM 2 19 13 0 8 0 104.0 ft2 0 0 0.6 0 23 S Exterior Frame- Wood BEDROOM 2 19 12 2 8 0 97.3 ft2 0 0 0.6 0 24 S Exterior Frame - Wood BATH 2 19 5 0 8 0 40.0 ft2 0 0 0.6 0 WINDOWS Orientation shown is the entered, Proposed orientation. V Wall I Overhang # Ornt ID Frame Panes NFRC U-Factor SHGC Imp Area Depth Separation Int Shade Screening 1 SE 3 Metal Low-E Single Yes 0.65 0.25 N 12.0 ft2 1 ft 0 in 1 ft 4 in None None 2 N 4 Metal Low-E Single Yes 0.65 0.25 N 9.0 ft2 1 ft 0 in 1 ft 4 in None None 3 SE 5 Metal Low-E Single Yes 0.65 0.25 N 12.0 ft2 1 ft 0 in 1 ft 4 in None None 4 SE 5 Metal Low-E Single Yes 0.65 0.25 N 12.0 ft2 1 ft 0 in 1 ft 4 in None None 5 S 7 Metal Low-E Single Yes 0.65 0.25 N 15.0 ft2 1 ft 0 in 1 ft 4 in None None 6 S 12 Metal Low-E Single Yes 0.65 0.25 N 15.0 ft2 1 ft 0 in 1 ft 4 in None None 7 W 13 Metal Low-E Single Yes 0.65 0.25 N 30.0 ft2 1 ft 0 in 1 ft 4 in None None 8 W 18 Metal Low-E Single Yes 0.7 0.3 N 33.3 ft2 1 ft 0 in 1 ft 4 in None None 9 S 19 Metal Low-E Single Yes 0.65 0.25 N 8.0 ft2 1 ft 0 in 1 ft 4 in None None 10 E 22 Metal Low-E Single Yes 0.7 i 0.3 N 33.3 ft2 1 ft 0 in 1 ft 4 in None None 11 S 23 Metal Low-E Single Yes 0.65. 0.25 N 30.0 ft2 1 ft 0 in 1 ft 4 in None None I 5/22/2018 11:46 AM EnergyGauge® USA - FlaRes2017 Section R405.4.1 Compliant Software Page 4 of 6 - FORM R405-2017 INFILTRATION i # Scope Method SLA CFM 50 IELA EgLA ACH ACH 50 1 Wholehouse ProposedACH(50) .000356 1116.3 11.28 115.25 .2598 7 HEATING 'SYSTEM # System Type Subtype I Efficiency Capacity Block Ducts 1 Electric Strip Heat/ None COP:1 17 kBtu/hr 1 I sys#1 COOLING SYSTEM i # System Type Subtype Efficiency Capacity Air Flow SHR Block Ducts 1 Central Unit/ Split I SEER: 16 24 kBtu/hr 720 cfm 0.8 1 sys#1 HOT WATER SYSTEM i # System Type SubType Location EF I Cap Use SetPnt Conservation 1 Electric Tankless LAUNDRY 0.98 I 1 gal 60.9 gal 120 deg None SOLAR HOT WATER SYSTEM FSEC Cert # Company Name I Collector Storage System Model # Collector Model # Area Volume FEF None None I ft2 DUCTS — Supply — V/ # Location R-Value Area — Return -- I Air CFM 25 CFM25 Location Area I Leakage Type Handler TOT OUT QN RLF HVAC # Heat Cool 1 Attic 6 120 ft2 Attic 12 ft2 I Default Leakage CLOSET (Default) c(Default) c 1 1 TEMPERATURES i Programable Thermostat: N Coolin Jan Feb [ ]Mar HeatinJan HFeb [X] Mar VentingJan Feb [X] Mar Ceiling Fans: A r Ma Jun [X� Jul Auge Oct (� Nov j Apr f May Jun E j Jul Au4 Sep f Oct [X] Nov [xl Apr [ May Jun ]Jul Aug [ Se [X] Oct [X] Nov [ ]Dec [X] Dec [[ ]] Dec 5/22/2018 11:46 AM EnergyGauge® USA - FlaRes2017 Section R405.4.1 Compliant Software Page 5 of 6 FORM R405-2017 Thermostat Schedule: HERS 2006 Reference Schedule Type 1 2 3 Cooling (WD) AM 78 78 78 PM 80 80 80 Cooling (W EH) AM 78 78 78 PM 80 80 80 Heating (W D) AM 65 65 65 PM 68 68 68 Heating (WEH) AM 65 65 65 PM 68 68 68 I i Hours 4 i5 6 7 8 9. 10 11 12 78 i78 78 78 78 80 80 80 80 80 178 78 78 78 78 78 78 78 78 178 78 78 78 80 80 80 80 80 '78 78 78 78 78 78 78 78 65 65 65 65 68 68 68 68 68 68 68 68 68 68 68 68 68 68 65 65 65 65 68 68' 68 68 68 68 68 68 68 68 68 68 68 68 I i i I I I I I I 5/22/2018 11:46 AM EnergyGauge® USA - FlaRes I017 Section R405.4.1 Compliant Software Page 6 of 6 2017 - AIR BARRIER AND INSULATION INSPECTION (COMPONENT CRITERIA TABLE 402.4.1.1 AIR BARRIER AND INSULATION INSPECTION COMPONENT CRITERIA Project Name: PARENT RESIDENCE Builder Name: MEL- RY CONSTRUCTION Street: 2044 NETTLES BLVD. Permit Office: ST LUCIE COUNTY City, State, Zip: JENSEN BEACH, FL, 34957 Permit Number: 1804-0648 Owner: Jurisdiction: ST LUCIE COUNTY Design Location: FL, Fort Pierce COMPONENT AIR BARRIER CRITERIA INSULATION INSTALLATION CRITERIA General A continuous air barrier shall be installed in the building envelope. Air -permeable insulation shall requirements The exterior thermal envelope contains a continuous air barrier. not be used as a sealing material. Breaks or joints in the air barrier shall be sealed. The air barrier in any dropped ceiling/soffit shall be aligned with the Ceiling/attic insulation and any gaps in the air barrier shall be sealed. ed ceiling/soffit The insulation in any dro g /soffit shall be aligned with the ap barrier. Access openings, drop down stairs or knee wall d006 to unconditioned attic spaces shall be sealed. Walls The junction of the foundation and sill plate shall be sealed. Cavities within corners and headers of frame walls shall The junction of the top plate and the top of exterior walls shall be sealed. be insulated by completely filling the cavity with a Knee walls shall be sealed. material having a thermal resistance of R-3 per inch minimum. Exterior thermal envelope insulation for framed walls shall be installed in substantial contact and continuous alignment with the air barrier. Windows, skylights The space between window/doorjambs and framing, and and doors skylights and framing shall be sealed. Rim joists Rim joists shall include the air barrier. I Rim joists shall be insulated. Floors The air barrier shall be installed at any exposed edge of insulation. Floor framing cavity insulation shall be installed to (including maintain permanent contact with the underside of above -garage subfloor decking, or floor framing cavity insulation shall and cantilevered floors) be permitted to be in contact with the top side of sheathing, or continuous insulation installed on the underside of floor framing and extends from the bottom I to the top of all perimeter floor framing members. Crawl space walls Exposed earth in unvented crawl spaces shall be covered with a Where provided instead of floor insulation, insulation Class I vapor retarder with overlapping joints taped. shall be permanently attached to the crawlspace walls. Shafts, penetrations Duct shafts, utility penetrations, and flue shafts opening to exterior or unconditioned space shall be sealed. Batts in narrow cavities shall be cut to fit, or narrow Narrow cavities cavities shall be filled by insulation that on installation readily conforms to the available cavity spaces. Garage separation Air sealing shall be provided between the garage and conditioned spaces. Recessed lighting Recessed light fixtures installed in the building thermal envelope shall Recessed light fixtures installed in the building be sealed to the drywall. I thermal envelope shall be air tight and IC rated. Plumbing and wiring Batt insulation shall be cut neatly to fit around wiring and plumbing in exterior walls, or insulation that on i installation readily conforms to available space shall extend behind piping and wiring. Shower/tub The air barrier installed at exterior walls adjacentlto showers and Exterior walls adjacent to showers and tubs shall be on exterior wall tubs shall separate them from the showers and tubs. insulated. Electrical/phone box on The air barrier shall be installed behind electrical or communication exterior walls boxes or air -sealed boxes shall be installed. HVAC register boots HVAC register boots that penetrate building thermal envelope shall be sealed to the sub -floor or drywall. Concealed When required to be sealed, concealed fire sprinklers shall only be sealed sprinklers in a manner that is recommended by the manufacturer. Caulking or other adhesive sealants shall not be used to fill voids between fire sprinkler cover plates and walls or ceilings. I a. in addition, inspection or log walls shall be In accordance with the provisions of ]CC-400. 5/22/2018 11:46 AM EnergyGauge® USA - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 1 of 1 FORM R405-2017 ENERGY PERFORMI�NCE LEVEL (EPL) DISPLAY CARD ESTIMATED ENERGY PERFORMANCE INDEX* = 99 The lower the EnergyPerformance Index, the more efficient the home. 2044 NETTLES BLVD., JENSEN BEACH, FL, 34957 1. New construction or existing 2. Single family or multiple family 3. Number of units, if multiple family 4. Number of Bedrooms 5. Is this a worst case? 6. Conditioned floor area (ftZ) 7. Windows- Description a. U-Factor: Sgl, U=0.65 SHGC: SHGC=0.25 b. U-Factor: Sgl, U=0.70 SHGC: SHGC=0.30 c. U-Factor: N/A SHGC: d. U-Factor: N/A SHGC: Area Weighted Average Overhang Depth: Area Weighted Average SHGC: New (From Plans) Single-family 1 2 No 1196 Area 143.00 ft2 66.67 ftZ ftZ ftZ 1.000 ft. 0.266 8. Floor Types Insulation Area a. Slab -On -Grade Edge Insulation R=0.0 1196.00 ftZ b. N/A R= ftZ c. N/A R= ftZ I certify that this home has complied with the Florida Energy E Construction through the above energy saving features which in this home before final inspection. Otherwise, a new L D based on installed Code compliant features. 9. Wall Types a. Concrete Block - Ext Insul, Exterior b. Frame - Wood, Exterior c. Frame- Wood, Exterior d. N/A 10. Ceiling Types a. Under Attic (Vented) b. N/A c. N/A 11. Ducts a. Sup: Attic, Ret: Attic, AH: CLOSET 12. Cooling systems a. Central Unit 13. Heating systems a. Electric Strip Heat 14. Hot water systems a. Electric b. Conservation features None 15. Credits ency Code for Building be installed (or exceeded) ,y Card will be completed Builder Signature: C Date Address of New Home: i I . �L, � c� City/FL Zip: Insulation Area R=4.1 1158.70 ftZ R=19.0 377.33 ftZ R=11.0 160.00 ftZ R= ftZ Insulation Area R=30.0 1196.00 ftZ R= ftZ R= ftZ R ftZ 6 120 kBtu/hr Efficiency 24.0 SEER:16.00 kBtu/hr Efficiency 17.0 COP:1.00 Cap: 1 gallons EF: 0.98 None *Note: This is not a Building Energy Rating. If your Index is below 70, your home may qualify for energy efficient mortgage (EEM) incentives if you obtain a Florida EnergyGauge Rating. Email EnergyGauge tech support at techsupport@energygauge.com or see the EnergyGauge web site at energygauge.com for information and a list of certified Raters. For information about the Florida Building Code, Energy Conservation, contact the Florida Building Commission's support staff. **Label required by Section R303.1.3 of the Florida Building Code, Energy Conservation, if not DEFAULT. I I 5/22/2018 11:46 AM _ EnergyGauge® USA - FlaRes2017 - Section R405.4.1 Compliant Software Page 1 of 1 � I Job: wri htsoft® Project S I� Date: Apr 12, 2018 9 Entire House By: QUICK CALCS, INC. i 317 ST LUCIE LANE, FORT PIERCE, FL 34946 Phone: 772-466-6799 Fax 772-466-6796 Email: QUICKCALCS ,AOL.COM i Rro'ect Information For: PARENT RESIDE MEL-RY CONSTRUCTION ICE, 2044 NETTLES B VD., JENSEN BEACH, FL 34957 Notes: Design Information Weather: Fort Pierce, FL, US Winter Design Conditions Summer Design Conditions Outside db 42 OF Outside db 90 OF Inside db 70 °FI Inside db 75 OF Design TD 28 °p Design TD 15 OF Daily range M Relative humidity 50 % Moisture difference 61 gr/lb Heating Summary Sensible Cooling Equipment Load Sizing Structure 19256 tuh Structure 1;3639 Btuh Ducts 2926 Btuh Ducts 4248 Btuh Central vent (0 cfm) 0 ¢tuh Central vent (0 cfm) 0 Btuh Humidification 0 Btuh Blower 0 Btuh Piping 0 Btuh Equipment load 22182 Btuh Use manufacturer's data in Rate/swing multiplier 0.95 Infiltration Equipment sensible load .16993 Btuh Method simplified Latent Cooling Equipment Load Sizing Construction quality Average Fireplaces 0 Structure 3103 Btuh Ducts 1117 Btuh Heating Coalingg Central vent (0 cfm) 0 Btuh Area (ft2) 1196 1196 Equipment latent load 4220 Btuh Volume (fta) 10013 10013 Air changes/hour 0.45 0.23 Equipment total load 21213 Btuh Equiv. AVF (cfm) 75 38 Req. total capacity at 0.70 SHR 2.0 ton Heating Equipment Summary Cooling Equipment Summary Make I Make Rheem Trade Trade RHEEM Model Cond RA1624AJ 1 NA AHRI ref Coil RH1T2417STANJA I AHRI ref 7940891 Efficiency 100 EFF Efficiency 13.0 EER, ,16 SEER Heating input G.5 kW Sensible cooling 16800 Btuh Heating output 22182 Btuh Latent cooling 7200 Btuh Temperature rise 25 OF Total cooling 24000 Btuh Actual air flow 800 cfm Actual air flow 800 cfm Air flow factor 0.036 cfm/Btuh Air flow factor 0.045 cfm/Btuh Static pressure 1100 in H2O Static pressure 1.00 in H2O Space thermostat Load sensible heat ratio 0.81 Calculations approved byACCA to meet all requirements of Manual J 8th Ed. wrightsoft° 2018-Apr-1212:55:05 �- Right -Suite® Universal 2017 17.0.08 RSU08101 Pagel 'A EADocumnets\wrightsoft WAMPARENT RESIDENCE.rup Calc = MJ8 Front i I Door faces: S w + wrightsoft Right-J® Worksheet Entire House QUICK CALCS, INC. 317 ST LUCIE LANE, FORT PIERCE, FL 34946 Phone: 772.466-6799 Fax 772-466-6796 Email: QUICKCALCS ,AOL.COM Job: Date: Apr 12, 2018 By: 1 2 3 4 5 Room name Exposed wall Room height Room dimensions Room area ; Entire House 211.9 ft 8.4 ft 1195.6 ft2 DEN 18.0 ft 8.0 ft heat/cool 1.0 x 89.0 ft 89.0 ft' Ty Construction number Ll-value (Btuh/ftf-°F) Or HTM (Btuh/ft2) Area (ft2) or perimeter (ft) Load (Btuh) Area (ft2) or perimeter (ft) Load (Btuh) Heat Coop Gross N/P/S Heat Cool Gross N/P/S Heat Cool 6 1 Vj/, -. ` - --- ;13A4ocs ' 2 glazing, clr lowv4 . 2 glazing,, oir low�e,;,.___ 13A-4ocs 2 glazing, clr low-e 13A-0ocs.. 2 glazing, clr low-e 2 glazing, dr low-e 13A-4ocs 2 glazing, clr low-e 2 glazing, cir low-e 11DO 13A-flocs - 2 glazing, clr low-e,-' 2-glazing,_clr low-e� 1613-30md_ ---- -- 0.143 0.650 _ - - _0,650 0.143 0.650 0.143 0.650 '� 0.650 0.143 0.650 0.650 _ _ 0.390 0143 '. 0.650' .� _0 650 - 0.032 --- n n a a se se 'se s s s __.s_ w w _w _ _ _ -.. -- 4.06, 18.20 18_20 4.00 18.20 406 18.20 18.20 4.00 18.20 18.20 __10:92 4.00 18.20 _ 18.20 _ 0.90 - ' 219 14! 99 _rt 1g'.99 2.19 33.77 21g_ 26.27 __ 25 27 219 14.99 14.99 10.34 )2.19 33.77 33.77 I 1.60 ---- r 600 9 8 - - 240 34 215 12 __24 -409 8 60 20 344 - 30 __34 _861 861 ------ 583 0 0 -- - 206 --0 179 2 4 �- 321 8 60 -_ _ _20 280 0 _ _ 0 _,. 861 - - -150 --- 2334 164 146 825 _ -619 717 212 _ __ 437 -1285 146 1092 _223 1121 546 `- 919 771- _ .- 5689 - -- --- 1276 135 120 - 451 _ 1148 392 295 606 702 120 899 211 - 613 1013 _ 1148 1378 .- - - 0 - - - - 56 0 0 `0 0 0 0 _ 0 J 0 0 0 _ _ 0 88 0 _ 34 _._ _ _ 89 -- - 0 - -- 56 0 _ _ _0 - 0 -_ _ 0 0 0 0 y 0 0 0 0 54 0 89 -- - - .0 - --- -- 224 0 _ _ _ __0 0 -0 0 0 _- 0 -0 0 0 0 216 0 -__ 80 - - - 0 -- - 123 0 0 _ _ -0 -0 0 _-__ 0 0 0 0 0 118 0 _ _ 142.. - ----0 y1 - + _ C _ 6 I c)AED excursion 0 284 Envelope loss/gain 16945 10507 1139 1816 12 a) Infiltration b) Room ventilation I 2311 0 633 0 184 0 50 0 13 i Internal gains: Occupants @ 230 Appliances/other 0 0 2500 0 0 500 Subtotal (lines 6 to 13) i 19256 13639 1323 2366 14 15 Less extemal load Less transfer I Redistribution Subtotal Duct loads , 15% 31% 0 0 0 19256 2926 0 0 0 13639 4248 16% 31% 0 0 5 1328 2021739 0 0 8 2374 Total room load I Air required (cfm) 22182 800 17887 800 1530 55 3113 139 C -�- wrigl7tSOft' RightSuite® Universal, 2017 17.0.08 RSU08101 �� E:1DocumnetsMightsoft WAMPARENT RESIDENCE.rup Calc = MJ8 Front Door faces: S 2018-Apr-12 12:55:05 Page 1 i - - wrightsoft RighW@ Worksheet Entire House QUICK CALCS, INC. i 317 ST LUCIE LANE, FORT PIERCE, FL 34946 Phone: 772466-6799 Fax 772-466-6796 Email: OUICKCALCS@AOL.COM Job: Date: Apr 12, 2018 By: 1 Room name j STAIRS BATH 2 2 E)posed wall 19.0 ft 19.0 ft 3 4 5 Room height Room dimensions Room area 15.5 ft heat/cool 15.0 x 4.0 ft 60.0 ft2 8.0 ft heat/cool 1.0 x 81.0 ft 81.0 ft' Ty Construction Ll-value Or HTM Area (ft') Load Area (ft') Load number (Btuh/ft�°F) (Btuh/ft') i or perimeter (ft) (Btuh) or perimeter (ft) (Btuh) Heat Cool) Gross N/P/S Heat Cool Gross N/PIS Heat Cool 6 11 -- ' .13bs ' ' '-- 2 glazing,-clr lower '- 2 glazin ,_clr lower _. 19A-0ocs _ �- -. 2 glazing, clr lower 13A-4acs -. ---_0 glazing, clr low-e 2 glazing,, clr lower -'- �0:143 .0.650 0.650 -_ ._ 0.143 0.650 143 0 650 0_650 n n n '-e - a 4.00 18.20 18.20 -- 4.00 18.20 ' 2:19 14.99 14.99 -- - zh'-9 33177 211-9 25127 :_ 25.27 .- - 232 0 8 -- --- 32 0 6 0 0 ' -- - -224 0 0 - -- 82 0 0 0 0 0 146 - 128 0 00-, 0 0 0 120 - 70 0 0 --0-,-- 0 =0 0 0 -0662 0 0 _ --_ _- 0 0 0 0 _- __ 0 0 0 0 -- 0 -_ _ 0 0 0 0 _ -y-/ - - La se. se se 4.00-: 18.20 18.20 0 13A-4ocs glazing, clr low-e ___ 0.143 0.650 s- s - - 4.00 18.20 - i,19 14.99 ______ _ -0 0 ...... - 0 0 _ - 0 0 _ - 0 0 80 8 72 8 288 146 158 120 G2 _---D 2 glazing, clr low-e 11D0 _ .._ _ - - . 13A-4ocs 0.650 _ 0.390 0.143 s --s- w 18.20 ---10.92 4.00 14.99 _ 10.34 2.19 0 ----- 0 0 0 0 0 0 - 0 0 0 -- - 0 0 - - -0 72 0 - ------0 72 0 -- -_0 288 0 -- - -0 158 - 2 glazing, clr low-e, 2gl_azing,.clr low-e 0.650 __--0.650 w. 18.20 33.77 ,._-33.7Z -0 �._ -0 0 �------'QQ 0 --0 0 _. - - 0 0 - ----0 0 .._-0 0 0 --- C 166_30md_ _-- _18.20 0.90 1.66 60 54 96 �3 ---_ 130 _- F-- _ _._---- 22AFph-- - -- -- -_0.032 __� 1,358_-__- _ _. - 38,02_..0.00 - _ -•--- ---- - _•-_^_60 - --___-- - _ _ -- _-_-81 11 _-_--81 .3 _ _ -- _98._._-_ Q ---------- - --- -- 6 c)AED excursion -68 -46 Envelope loss/gain i 1757 708 893 519 12 a) Infiltration 337 92 194 53 b) Room ventilation 0 01 0 0 13 Internal gains: Occupants @ 230 0 0 0 0 Appliances/other 0 0 Subtotal (lines 6 to 13) 2094 801 1087 572 Less external load 0 0 0 0 Less transfer 0 0 0 0 Redistribution 55 40 0 0 14 Subtotal 2150 841 1087 572 151 Duct loads 115% 31% 327 262 15% 31% 165 178 Total room load 1 2476 1103 1252 750 Air required (cfm) 189 49 45 34 ACCPk - wrsightoft` RightSuite® Universal 20117 17.0.08 RSU08101 E:SDocumnetslWrightsoft HVACIPARENT RESIDENCE.rup Calc = MJ8 Front Door faces: S 2018-Apr-12 12:55:05 Page 2 * wrightsoft i i I Right-J® Worksheet . Entire House QUICK CALCS, INC. I 317 ST LUCIE LANE, FORT PIERCE, FL 34946 Phone: 772-466-6799 Fax 772-466-6796 Email: QUICKCALCS@AOL.COM Job: Date: Apr 12, 2018 By: 1 2 3 4 5 Room name Exposed wall j Room height Room dimensions Room area j AHU 0 ft 8.0 ft heat/cool 3.0 x 3.0 ft 9.0 ft, CLST 2 2.0 ft 8.0 ft heat/cool 12.0 x 2.0 ft 24.0 ftz Ty Construction number U-value (Btuh/ft;°F) Or HTM j (Btu ft) Area (ftz) or perimeter (ft) Load (Btuh) Area (ftz) or perimeter (ft) Load (Btuh) Heat Cool Gross N/P/S Heat Cool Gross N/P/S Heat Cool 6 11 2.glazing, clr lower` 2glazing,'clrlow-e_- . 13AAacs 2 glazing, clr low-e - 13A-4ocs' 2 glazing, clr lowm 2 glazirig, clr lower 13A- ocs 2 glazing, clr lower 2 glazing, clr low-e 11D0 -- - - 13A-4ocs 2 glazing, cl� lower 2glazing,clrlow-e 16630md .._- - 'tph 0.143 0.650 _---0.650 0.143 0.650 0.143 0.650 �0,650 0.143 0.650 0.650 ---0.390 0 143 0.650 •--_--0.650 _._. 0.032 n n __ n a ^ e se se se' _s s s s _. w w _w - - 4.00 18.20 _-18.20 4.00 -_ 18,20 4.00 18.20 18.20 - 4.00 18.20 18.20 10.92 4.00 18.20 -_ 18.20 0.90. -X02, -- 2.19.-_ 14.. 9 _ _14.99 2.(19 - 33:77 2719 25127 . 25127 2 19 141.99 14.99 _r10.34 2' 19 33 77 __3377_ ., ..:1.60 0,00 - o------0 0 __----_.-Q 6 0 -0 0 . ' 0 - `p 0 0 - 0 0 0 ._...-_9- -- -- 9 . - - -0 0 _-__- 0 0 0 0 0 0 --- 0 0 0 ---- 0 0 0 ------ -- - 9 --- - 0 -- d-- 0 _.__0 0 - 0 0 0 0 ---- 0 0 0 _- - 0 0' 0 -- -8 - - ---0 0 -- - -- -0 0 0 - - ^-0 0 0 0 0 0 - 0 0 - -- 14 - - - --- 0 0 ------_O. 16 0 -- — 0 0 0 — 0 0 - --- 0 16 0 --' -- 0, 0 0 ---•- 0 0 --- _-0 64 0 - .0 0 0 -------0 0 ---_-0 35 0 -- - 0 0 0 0 0 0 0 0 - 36 ----- 0 II---_GG VU -- L-G I�-GG __ _ G -r-�D :. C-- _ F -- 0 0 - -- -0 0 0 --------24 ----- 0 0 0 - ---0 0 0 -_.. 24 -- -- _0 0 0 -= --0 0 0 ---0------0- - --22 -- 6 c)AED excursion l I -1 6 Envelope loss/gain I 8 13 86 67 12 a) Infiltration b) Room ventilation j 0 0 0 0 20 0 6 0 13 Internal gains: Occupants @ 230 I Appliances/other 0 0 0 0 0 0 i Subtotal (lines 6 to 13) I 8 13 106 73 14 15 Less external load Less transfer Redistribution i Subtotal Duct loads 15% 31% 0 0 -8-13 0 0 0 0 0 0 15% 31% 0 0 106 0 0 0 0 -73 0 0 Total room load Air required (cfm) 0 0 0 0 0 0 0 0 J 8th Ed. ACA '� WrightsOft` RightSuite® Universal 2017 17.0.08 RSUD8101 E:1Documnets%Wdghtsoft HVAC%PARENT RESIDENCE.rup Calc = MJ8 Front Door faces: S 2018-Apr-12 12:55:05 Page 3 - wrightsoft' Right-M Worksheet Entire House i QUICK CALCS, INC. 317 ST LUCIE LANE, FORT PIERCE, FL 34946 Phone: 772.466-6799 Fax 772466-6796 Email: QUICKCALCS@!AOL.COM Job: Date: Apr 12, 2018 By: 1 2 3 4 5 Room name E)posed wall I Room height Room dimensions Room area BEDROOM 2 25.1 ft 8.0 ft heat/cool 1.0 x 166.5 ft 166.5 ft- LIVING ROOM 14.0 ft 8.0 ft heat/cool 14.0 x 13.0 ft 182.0 ft' Ty Construction number U-value (Btuh/ft�°F) Or HTM I (Btuh/ft') Area (ft') or perimeter (ft) Load (Btuh) Area (ft') or perimeter (ft) Load (Btuh) Heat Cool l Gross N/P/S Heat Cool Gross N/P/S Heat Cool 6 11 1/// 1 9A-0ocg, 2 glazing, clr low-e 2 glazing,_clr low e . _ 13A-4ocs ---- - 2 glazing, clr low e _ 13A-4ocs ~ - 2 glazing, clr low-e 2 glazing, clr low-e - 1-3A-4ocs 2 glazing, clr low-e 2 glazing, clr low-e 11D0----__--- 13A13ocs 2 glazing; clr low-e 2 glazing, clrImt _- 16B30md- - - 0.650 0.650 0.650 - - 0.143 0.650 - -0:143 -0.650 0.650 n n n -o- a se se se 4.20 18.20 18:20 -. - 4.00 18.20 - 4:00 18.20 2.119 14. 99 4.99 14. 2.19 33 77 2I19 25!27 - 0 0 -104 - 34 0 0 0 0 ----- 70 0 --___ O 0 _- 0 0 __ 0_ - - 280 619 _ - 0 0 0 153 1148 - 0 0 0 0 0 0 -_ + 0 0 � 0 307 0 273 _ 223 0 0 -0 632 0 0 0 0 - -0 0 ._ 0 168 0 225 ---- _-211 0 0 -0 �_- -0 0 0 0 0 -�- 0 0 0 112 0 15 --- __-20 0 0 0 0 0 0 -- - 0 0 0 II---GG ----'- V�/ I--G -y!'- IL---GG - W �� 0.143 0.650 0.650 _ _-_- 0.390 A 143 0.650 ;._0 650 . s s s -s w w -w_ - -18.20 4.00 18.20 18.20 _-10.92. 4.00 18:20 18.20 --0:90 02 _25:27 2.19 14.99 14.99 -.1.0..34 2.19 33.77 I1,60 0 00 97 0 30 --w---- 0 0 0 -- 167 _ __. 28 67 0 30 -Y- __ 0 - 0 0 - 167 4 _-_-0 269 0 546 _ _ _ _-0 0 0 �-_149 _ 160 -___-0 147 0 450 -- 0 0 0 ---266 - _- 0 �- 77 0 15 __ _ _ 20 - 0- 0 - 0 _ 14 C_ _- ---- 0.032 --- -0 182 6 c)AED excursion I -213 -155 Envelope loss/gain I 2024 1951 1335 448 12 a) Infiltration b) Room ventilation 257 0 70 01 143 0 39 0 13 Internal gains: Occupants @ 2301 Appliances/other 0 0 500 0 0 1500 Subtotal (lines 6 to 13) I 2281 2522 1478 1987 14 15 Less extemal load Less transfer I Redistribution Subtotal I Duct loads ! 15% 31% 0 0 54 2335 355 0 0 38 2560 797 15% 31% 0 0 32 1510 229 0 0 7 1995 621 Total room load I Air required (cfm) I 2689 97 3357 150 1740 63 2616 117 :CA to meet all rec _ Wri9~lt'a RightSuite® Universal 2Q17 17.0.08 RSU08101 �� E:\Documnets\Wrightsoft FNAC\PARENT RESIDENCE.rup Calc = MJ8 Front Door faces: S 2018-Apr-12 12:55:05 Page 4 ' -• wrightsoft, Right-J® Worksheet Job: Entire House I Date: Apr 12, 2018 QUICK CALCS, INC. 317 ST LUCIE LANE, FORT PIERCE, FL 34946 Phone: 772466-6799 Fax 772;466-6796 Email: QUICKCALCS ,AOL.COM 1 2 3 4 5 Room name EVosed wall Room height Room dimensions Room area KITCHEN 35.0 ft 8.0 ft heat/cool 1.0 x 240.0 ft 240.0 ft2 BEDROOM 34.0 ft 8.0 ft heat/cool 1.0 x 162.0 ft 162.0 ft' Ty Construction number U-value (Btuh/ft�°F) Or HTM (Btuh/ft2) Area (ftz) or perimeter (ft) Load (Btuh) Area (ftz) or perimeter (ft) Load (Btuh) Heat Cool I Gross N/P/S Heat Cool Gross N/P/S Heat Cool 6 11 U�/�G 2.19 14.96 _. _ 14.99 2.19 33.77 120 ' 9 ,_ _._ Q 0 0 111 0 --_----°-0 0 0 444 164 . --_-_ 0 0 0 243 135 . �0 0 0 "- 164 0 0 0 --'- 104 0 0 0 0 0 _ 0 0 0 _ 0 _ - 13A flocs 2 glazing; clr Wi-e , glazing,_clir,low-e .0 _ 13AAocs 2 glaing,zclr low- "IJN'3 0.650 - - 0.650 0.143 0.650 , n n ,._ n a a 4.00 18.20 _ 18,20 4.00 18.20 y/ LG G 13A446cs 2 glazing, clr low-e, , 2 glazing, clr low a 13A-4ocs 2 glazing, clr low-e - 2 glazing, clr low-e 11D0 _--... _ ..-,. 13A11ocs 2 glazing, clr low4 . 2 glazlri& lower 16B30md 22A tph - -` 0.143 0.650 0.650 se. se se 40(y 18.20 1820 2.19 25.21 25.27 136 12 12 _ 0 0 0 0 } 24 0 - -'-0 _ 182 _--_ 240 _ - 112 2 _ _. 2 - 0 0 0 0 24 0 �� 0 182 _35 _ 450 212 _ 218 - 0 0 0 ---- _0 96 0 - -----0 163 1331.129$ " 246 295 _ -- 303 - 0 0 0 --- . 0 53 0 - - �_ _Q 292 _ -' 0 0 _ 0 56 0 15 _-... . 0 112 30 --___ _124 �- 0 0 0 - 41 0 15 . -_ - 0 82 0 .-_ __ 0 124 0 0 _'0 164 0 273 - -- -0 328 546 _-_-Q 111 -0 0 __- 0 - 90 0 225 0 .179 1013 _ �. _Q _ 198 -G 0.143 0.650 0.650 _0.390 0143 0:650 0_650 _ s s s 5: . w w �w - 4.00 18.20 18.20 ._ .10.92. 4 00 18 20 18 20- 0.90 _ _ 2.19 14.99 14.99 10.34 2 19 33 T/ --33 T/ 1.60 D b \� LL---_GG- C _-.� 0.032 1,358 F _ 38.02 6 c)AED excursion 18 191 Envelope loss/gain 3079 158413132 2124 12 a) Infiltration b) Room ventilation I 358 0 98 0 348 0 95 0 13 Internal gains: Occupants @ 230 1 Appliances/other 0 0 0 0 0 0 Subtotal (lines 6 to 13) I 3437 1682 3479 2219 14 15 Less external load Less transfer Redistribution Subtotal Duct loads 15% 31% 0 0 0 3437 522 0 0 0 1682 524 15% 31% 0 0 128 3608 548 0 0 30 2249 701 Total room load Air required (cfm) 3959 1431 2205 99 4156 150 2950 132 all requirements of Manual J 81 s4GCA Wright50ft' Right -Suite® Universal 2017 17.0.08 RSU08101 E:\Documnets\Wrightsoft HVAC\PARENT RESIDENCExup Calc = MJ8 Front Door faces: S 2018-Apr-12 12:55:05 Page 5 -�- wrightsoft Right-J® Worksheet Job: Entire House Date: Apr 12, 2018 QUICK CALCS, INC. 317 ST LUCIE LANE, FORT PIERCE, FL 34946 Phone: 772466-6799 Fax 772-466-6796 Email: QUICKCALCS@/10L.COM 1 2 3 4 5 Room name E)posed wall Room height Room dimensions Room area BATH 17.0 ft 8.0 ft heat/cool 8.0 x 10.0 ft 80.0 ftz LAUNDRY 26.8 ft 8.0 ft heat/cool 1.0 x 90.1 ft 90.1 ftz Ty Construction number U-value (Btuh/ft2°F) Or HTM (Btuh/ft') Area (ft') or perimeter (ft) Load (Btuh) Area (ft2) or perimeter (ft) Load (Btuh) Heat Cool I Gross � N/P/S Heat Cool Gross N/P/S Heat Cool 6 11 L-G i= G ��/-G 13A-0ocs -' - 2 glazing, clr lower -'u 2glazing, clrlo*46 13AAocs 2 glazing, clr low_-e 13A�ocs . 2 glazirig,,clr lower 2 glazing,-clr low e _ 13A-4ocs 2 glazing, clr low-e 2 glazing, clr low-e 11DO --_- 13A-flocs '- 2 glazing, clrJow� 2_glazing- rlow%;._ 1613-30md "-0.143 0:650 M 0.143 0.650 - .n0.650 n n a a ;- se se se s s s s - - w w. w.-.-.18_20 - 4.00 18.20 18.20 4.00 18.20 4.00 . 18.20 18 20 4.00 18.20 18.20 10.92 4 - 18.20 2:19 14.99 _1499 - 2.19 33.7� 2:19 25.27 -_25;27, 2.19 14.99 14.69 10.34 2.19 33.77 ---33,T1 0 0 0 - 24 0 .-D 0 -0 64 0 0 0 --48 0 0 "-- 0 0 ,• 0 -- 24 _ _- 0 0 0 0 64 0 0 _- 0 -v48 0 ------- Q 35 _ 17.- -'� 0 '0 _ 0 ' 96 0 --- - --. 0 0 0 256 0 0 _ 0 ' 192 0 --.-- 0 31 _ -�- 0 0 0 53 0 - - 0 0 . 0 140 0 0 _ 0 ' 105 0 .-__.-._ Q ---'- 72 -0 -__ 0 v 64 0 - -- 79 0 _ �. 12 0 0 0 _ _0 0 0 ____ 0 _ 90 _-__90 ^---1--72 0 0 - 64 0 ---- 67 0 -_ 2 0 0 0 0 0 _---0._ 90 __-..v_27 0 - '0 256 -�_ 0 267 . 0 _ -__218 0 0 0 0 0 _ � 81 0 _ 0 -140 0 - - --- 146 0 303 0 0 0 0 0 -- 0 144 0143 -0.650 ; 0-I 59 0.143 0.650 0.650 0.390 , .014-3 • 0 650 �_ _0.650 C 0.032 - 0.90 38_02 1M ____ -90 __ _ 35 _ _�$0 56 __- _0 --_ 6 c)AED excursion S1 31 Envelope loss/gain I 1222 322 2131 922 12 a) Infiltration b) Room ventilation 1 174 0 48 0 275 0 75 0 13 Internal gains: Occupants @ 230 Appliances/other 0 0 0 0 0 0 Subtotal (lines 6 to 13) 1396 370 2406 997 14 15 Less e)demal load I Less transfer Redistribution Subtotal Duct loads 115% 31% 0 0 0 1396 212 0 0 0 370 115 15% 31% 0 0 0 2406 366 0 0 0 997 311 Total room load I I Air required (cfm) I 1 1 1608 58 485 22 1 1 2772 100 1308 59 J 8th Ed. wrigl7tsOft` RightSuiteO Universal 2017 17.0.08 RSU08101 E:%Documnets\Wrightsoft HVAC\PARENT RES]DENCE.rup Caic = MJ8 Front Door faces: S 2018-Apr-12 12:65:05 Page 6 • II • - wrightsoft' Right-J® Worksheet Entire House QUICK CALCS, INC. 317 ST LUCIE LANE, FORT PIERCE, FL 34946 Phone: 772-466-6799 Fax 772-466-6796 Email: QUICKCALCS !AOL.COM Job: Date: Apr 12, 2018 By: 1 2 3 4 5 Room name Exposed wall Room height Room dimensions Room area CLST 2.0 ft 8.0 ft heat/cool 2.0 x 6.0 ft 12.0 ft- Ty Construction number U-value (Btuh/ft? °F) Or HTM (Btuh/ft=) Area (ftz) or perimeter (ft) Load (Btuh) Area or perimeter Load Heat Cool Gross N/P/S Heat Cool Gross N/P/S Heat Cool 6 11 Val �G 13A-4ocs. ` 2 glazing clr low-e g,glaimg:cIrlow-e_-". 13A-4ocs 2 glazing, clr low-e _.__ 13A�ocst., 2 glazing clr low-e `2 glazing, clr low-e 13A-4ocs 2 glazing, clr low-e 2 glazing, cir low-e 11D0._ _ -...- '13A1}ocs " 2 glazing, cir lo" ' 2 glazing; I low-e,..__. 16B-30md _T 0.143 0.660 _ _-. 0.650 0.143 0.650 0.143 0.650 _ _v 0.650 -0.143 0.650 0.650 _ 0.390 0143 0.650 _ _ 0_650 _6.0 2 1.358 ,n n' _ n e a se se se -s s s . s _ w w _w_ - - 4.00 18.20 __18.20 V 4.00 18.20 --_. 4:00 18.20 18.20 4.00 18.20 18.20 ._, 10.92 4.00 18.20 _18.20 0.90 . 38.02 2.19 14.99 14.99 33.77 2.19 25.27 _ 25�27 2.19 14.99 14.99 ,_. _ 10.34 219 33.77 33.77 1.60 _ 0:00 I ` 16 0 4 0 0 0 __T 0 0 0 0 0 0 - - ---- - _---_.-. Vt/-^ _ �---G_ - ._ _ __ 0 0 0 ___----- 0 - 0 0 0 _._._0 0 0 .----- --0 - __76 _ _ 0 0 0 ___--- 0 - 0 0 0 --- ___ 0 0 -' ._�0 - 0 0 0 _._. 0 0 0 _ . '- 0 0_' _. __- - - 0 0 0 --0 0 0 - _-_--0 0 -___ ... 2 -- _-_----- -- �G _. -9 0 0 �o C F--°_..22Atpb1` -__ - 0 �92 -- 0 _�_� -----_..__ 71 6 c) AED excursion -3 Envelope loss/gain 140 32 12 a) Infiltration b) Room ventilation 20 0 6 0 13 Internal gains: Occupants @ 230 Appliances/other 1 0 0 0 Subtotal (lines 6 to 13) I 161 37 14 15 Less external load Less transfer Redistribution Subtotal Duct loads 115% 31% 0 0 -161 0 0 0 0 -37 0 0 Total room load Air required (cfm) 01 0 all reauirements of wrightBOft• Right -Suite® Universal 2017 17.0.08 RSU08101 2018-Apr-12 12:55:05 �� E:\Documnets\WrightsoftHVACkPARENTRESIDENCE.rup Calc = MJ8 Front Door faces: S Page 7 �a DucSystem SummaryJob: t St �d- wrightsoWDate: Apr 12, 2018 Entire House By: QUICK CALCS, INC. 317 ST LUCIE LANE, FORT PIERCE, FL 34946 Phone: 772-466-6799 Fax 772-466-6796 Email: QUICKCALCS a@/\OL.COM For: PARENT RESIDENCE, MEL-RY CONSTRUCTION 2044 NETTLES BLVD., JENSEN BEACH, FL 34957 External static pressure Pressure losses Available static pressure Supply / return available pressure Lowest friction rate Actual air flow Total effective length (TEL) Heating 1.00 in H2O 0 in H2O 1.00 in H2O 0.500 / 0.500 in H2O 1.000 in/100ft 800 cfm Cooling 1.00 in H2O 0 in H2O 1.00 in H2O 0.500 / 0.500 in H2O 1.000 in/100ft 800 cfm 205 ft Name Design (Btuh) Htg (cfm) Clg. (cfm) Design FR Diam (in) H x W (in) Duct Mat[ Actual Ln (ft) Ftg.Egv Ln (ft) Trunk BATH h 1608 58 22 1.000 5.0 Ox0 VIFx 9.2 150.0 st2 BATH 2 h 1252 45 34 1.000 5.0 Ox 0 VIFx 9.2 115.0 st1 BEDROOM h 4156 150 132 1.000 7.0 Ox0 VIFx 8.7 150.0 st2 BEDROOM 2 c 3357 97 150 1.000 8.0 Ox0 VIFx 8.2 115.0 st1 DEN c 3113 55 139 1.000 7.0 Ox0 VIFx 8.2 115.0 st1 KITCHEN h 3959 143 99 1.000 7.0 Ox 0 VIFx 33.2 170.0 st3 LAUNDRY h 2772 100 59 11.000 6.0 Ox 0 VIFx 35.4 170.0 st3 LIVING ROOM c 2616 63 117 1.000 7.0 Ox0 VIFx 7.4 150.0 st2 STAIRS h 2476 89 49 11.000 6.0 Ox0 VIFx 9.5 115.0 st1 Trunk Htg Clg Design) Veloc Diam H x W Duct Name Type (Cfm) (cfm) FR (fpm) (in) (in) Material Trunk st2 Peak AVF 513 428 1.000 778 11.0 0 x 0 ShtMetl st3 Peak AVF 243 157 1.000 695 8.0 0 x 0 VinlFlx st2 st1 Peak AVF 287 372 1 1.000 682 10.0 0 x 0 VinlFlx i A * wrightsoftm Right -Suite® Universal 2017 17.0.08 RSUD8101 AMN E:\Documnets\Wrightsoft HVAC\PARENT RESIDENCE.rup Calc = MJ8I Front Door faces: S 2018-Apr-12 12:55:06 Page 1 %IH Grill Htg Clg TEL Design Veloc Diam H x W Stud/Joist Duct Name Size (in) (cfm) (cfm) (ft) FR (fpm) (in) (in) Opening (in) Matl Trunk rb4 Ox 0 800 800 0 0 0 0 Ox 0 VIFx wrightsoft° RightSuite® 2018-Ar12 12:55:06 p Universal 2017 17.U.08 RSU08101 +C+A E:\Documnets\WrightsoftHVACkPARENTRESIDENCE.rup Calc = MJB Front Door faces I Page 2