HomeMy WebLinkAboutPRE-APPROVED PRODUCTSFBC APPROVED PRODUCTS LIST s
PRODUCT CATEGORY SUB CATEGORY MANUFACTURER
STRUCTURAL COMPONENTS ROOF DECK
STRUCTURAL COMPONENTS
0
r.
EXTERIOR DOORS
EXTERIOR DOORS
UNION CORRUGATING COMPANY
26 Gauge MasterRib Panel
UNION CORRUGATING COMPANY
26 Gauge MasterRib Panel
ELIXER DOOR AND METAL COMPANY
Series 407
ROLL -UP ASTA INDUSTRIES INC.
I Model203
THESE PLANS AND ALL PROPOSED WORK
ARE SUBJECT TO ANY CORRECTIONS
RE®UIREb BY FILD INSPECTORS THAT
MAYBE NECESSARY IN ORDER TO
-COMPLY WITH ALL APPLICABLE CODES.
SWIM
STRUCTURAL WALL
SWINGING
FRONT ELEVATION.. .
SCALE: 1/8' =1:
LEFT SIDE ELEVATION . .
SCALE: 1/8' =1'
j$oy . 05,? 1
ST. LUCIE C
BUILDING C
REVIEV
FOR COM
REVIEWED BY
DATE /27(/'
PLANS AND
MUST BE KEPT
NO INSPECTION
APPROVAL
No. & DATE
FL9555.2-R4
12/12/17
FL9555.2-R4
12/12/17
FL17996.5-R1
01/29/18
FL8868.1-R5
10/07/17
IMIT
JOB OR
. BE E
SCANNED
�Qgp� P���fif%l
UPANCY GROUP:
U
GENERAL NOTES.
CONSTRUCTIONTYPE:
11.8
1.
THESE PLANS PERTAIN ONLY TO THE STRUCTURE, INCLUDING MAIN WIND FORCE RESISTING SYSTEM, COMPONENTS AND.CLADDING, AND BASE RAIL
RISK CATEGORY:
I
ANCHORAGE. OTHER DESIGN ISSUES, INCLUDING BUT NOT LIMITED TO PLUMBING, ELECTRICAL, INGRESSIEGRESS, PROPERTY SET -BACKS, FINISH
FLOOR ELEVATIONS AND SLOPES, OR OTHER LOCAL ZONING REQUIREMENTS ARE THE RESPONSIBILITY OF OTHERS.
BUILDING ENCLOSURE TYPE:
ENCLOSED
2.
THESE STRUCTURES ARE DESIGNED AS NON -HABITABLE UTILITY/STORAGE BUILDINGS (RISK CATEGORY 1) CAPABLE OF SUPPORTING DEAD LOAD OF
WIND EXPOSURE CATEGORY:
C
THE STRUCTURE AND APPLICABLE LIVE AND WIND LOADS. IMPROVEMENTS NOT SPECIFICALLY ADDRESSED HEREIN, INCLUDING DOORS, WINDOWS,
OR.OTHER COMPONENTS NOT LISTED IN THE FBC APPROVED PRODUCTS LIST (THIS SHEET), AND NOT PROVIDED AND INSTALLED BY CARPORTS
ULTIMATE WIND SPEED (MPH):
150
ANYWHERE, INC., WHICH EXERT ADDITIONAL LOADS ON THE STRUCTURE SHALL BE THE OWNER'S RISK BECHTOL ENGINEERING AND TESTING, INC.,
SHALL NOT BE RESPONSIBLE FOR STRUCTURAL DAMAGE OR FAILURE DUE TO THE APPLICATION OF ADDITIONAL LOADS.
NOMINAL DESIGN WIND SPEED (MPH):
116
3.
ALL COMPONENTS AND CLADDING SHALL BE INSTALLED ACCORDING TO MANUFACTURER'S INSTALLATION INSTRUCTIONS.
MEAN ROOF HEIGHT (FEET):
15.71
4.
ALL STEEL TUBING SHALL BE 5QKSI GALVANIZED STEEL._ ALL FASTENERS SHALL BE GALVANIZED OR STAINLESS STEEL.
ROOF ANGLE (DEGREES):
14.0
5.
ALL FIELD FRAMING CONNECTIONS SHALLBE #12=14 x V SELF DRILLING SCREWS WITHOUT CONTROL SEAT: WASHER. ALL SHOP FRAMING
DESIGN PRESSURES (PSF):
CONNECTIONS SHALL BE WELDED.
ROOF:
6.
CONCRETE SHALL HAVE A MINIMUM COMPRESSIVE STRENGTH OF 2500 PSI AT 28 DAYS. THE REINFORCING STEEL SHALL BE MINIMUM GRADE 40.
ZONE 1:
+16.0 /-25.9
CONCRETE SLAB FOUNDATIONS SHALL BE REINFORCED WITH 6X6-W1 AXW1 .4 WELDED WIRE FABRIC COMPLYING WITH ASTM A 185, OR WITH
ZONE 2:
+16.0 /-36.5
SYNTHETIC FIBER REINFORCEMENT COMPLYING WITH ASTM C1116.
ZONE 3:
+16.0 /-57.6
DESIGN ROOF PRESSURES:
+16.01.30.8
7.
CONCRETE EXPANSION ANCHORS SHALL BE WEJ-IT ANKR-TITE MODEL AT1252, OR SLEEVE ANCHOR MODEL HSA 1260. OR EQUIVALENT.
WALLS:
8.
POSTIRAFTER BRACING: BRACE ON EVERY POSTIRAFTER CONNECTION, EXCEPT FOR END WALLS AND GABLE ENDS.
ZONE 4:
+26.7 /-29.1
ZONE 5:
+26.7I- 32.5
9..
SLAB FOUNDATION SUBGRADE SOILS SHALL BE TERMITE TREATED AND COVERED WITH 6 MIL VAPOR RETARDER PER SECTION R318.1 OF THE FLORIDA
DESIGN WALL PRESSURES:
+26.71.29.9
BUILDING CODE, SIXTH EDITION (2017) - RESIDENTIAL, AND SECTION 1816.1 OF THE FLORIDA BUILDING CODE, SIXTH EDITION (20M - BUILDING.
MINIMUM ALLOWABLE FOUNDATION SOIL CONTACT BEARING PRESSURE OF 2,D00 PSF IS ASSUMED.
SWINGING DOORS:
+29.91.36.9
10.
14 GA FRAMING: 2-1/2' x 2-1/2'.TUBE STEEL (TS) WITH 2-1/4' x 2-1/4' TS NIPPLES. ONCEALED FASTENERS, OR ATiACHME
12 GA FRAMING: 2-1/4' x 2-1/4' TS WITH 2 x Y TS NIPPLES. `�,.
ROLL -UP DOORS:.
+28.01.31.6
ryl�
ARE THE RESpONSISIMOFTHE
NOTE: 14GAFRAMING.
CONTRACTOR OF RECORD
RIG HT.SI DE .ELEVATION.. .
SCALE: 1/8' =1'
REAR ELEVATION
SCALE: 1/8' =1' '
METAL FRAMINGAND SIDING'PREFABRICATED BY
CARPORTS ANYWHERE
P.O. BOX 776
STARKE, FL 32091
THESE ENGINEERING DRAWINGS ARE THE PROPERTY
OF BECHTOL ENGINEERING & TESTING, INC. AND
CARPORTS ANYWHERE, INC.. THESE DRAWING MAY
NOT BE REPRODUCED WITHOUT THE WRITTEN
CONSENT OF BECHTOL ENGINEERING & TESTING, INC.,
AND CARPORTS ANYWHERE, INC.
THIS IS TO CERTIFY THAT THE CALCULATIONS AND SPECIFICATIONS
HEREIN HAVE BEEN PREPARED BY THE UNDERSIGNED PROFESSIONAL
ENGINEER, AND ARE IN ACCORDANCE WITH THE REQUIREMENTS OF
SECTION 1609 OF THE FLORIDA BUILDING CODE, SIXTH EDITION (2017).
THE PLANS ARE VALID UNTIL THE NEXT REVISION OF THE FLORIDA
BUILDING CODE: III)
_ a H: R,C ,
N.x'iim A
PROPOSED 'TnTR U
5401 OLD DIXIE HIGHWAY
FORT PIERCE, FLORIDA. .
revised. °"" 9/17/18
MM
BECHTOL ENGINEERING : RR/mkb NTS,
AND TESNNA bm
ccNw�nro cemoae�ru, ORRbUAL. AND MUEOW TMM 00 =6 RR. ^1O1"n' G180O2
OH
TB SHEETI CIF3
id
INSTALL 1/Y x 51/2' EXPANSION ANCHOR
THROUGH BASE RAIL WITHIN 6' OF EACH
BOW ALONG SIDES OR INSIDE EVERY
OTHER END WALL POST ALONG END
WALL SECTIONS
2' MINIMUM
Ei MINIMUM 2-1/4' EMBEDMENT
GROUND SURFACE
'v
MONOLITHIC CONC. FOOTING (25D0 PSI MIN.)
REINFORCED WITH 2 #Ss CONTINUOUS
CONCRETE MONO. SLAB BASE RAIL ANCHORAGE
1 Nol To Safe
TS TRUSSED RAFTER CHORD,
OR NONSTRUCTURAL HEADER
TS END POST OR DOOR/
WINDOW FRAME POST c
TS NONSTRUCTURAL HEADER
(12 GA FOR ROLL -UP DOOR FRAME),
BASE RAIL, OR WINDOW RAIL
2'x2'x2' 16 GA ANGLE CLIP
SECURE TO POST (EACH SIDE) AND
RAFTER CHORDIRAIL WITH (4) #12-14x 3W
SDF's, (2) ON BOTTOM AND (2) ON SIDE
NOTE: AT ROLL -UP DOOR OPENINGS,
POST SHOULD BE FLUSH WITH RAIL
END. CLIP POST TO RAIL ONLY ON
SIDE OPPOSITE THE OPENING.
POST TO NON-STRUCTURAL HEADER, BASE
RAIL, OR WINDOW RAIL CONNECTION DETAIL
� Not To Scale
1' 16 GAUGE FURRING CHANNEL FASTENED TO EACH
RAFTER WITH (2) #12-14 x 3W SELF -DRILLING FASTENER SPACED
NOT MORE THAN 48' O.C.
26 GA. METAL ROOF PANEL
L---TS RAFTER -7
ROOF PANEL ATTACHMENT
Not To Scale
3116'
48' 16 GA U-CHANNEL BRACE
BRACE ANGLE SHALL BE MIN.45•
TO MAX. 60' FROM HORIZONTAL
MINIMUM 6' LONG TS NIPPLE
SECURE RAFTER AND POST
TO NIPPLE WITH (4) #12-14 x 314'
SELF -DRILLING FASTENERS
I
RAFTER POST
BOX EAVE RAFTER/CORNER POST
CONNECTION DETAIL
Not To Scale
TS POST
(12 GA FOR ROLL -UP DOOR FRAME)
2' x 2' x 2' 16 GA ANGLE CLIP
SECURE TO POST AND TOP OF
HEADER, OR BOTTOM OF WINDOW
RAILIGIRT WITH #12-14x 3/4' SDPs
TS NONSTRUCTURAL HEADER
(12 GA FOR ROLL -UP DOOR FRAME)
TS WINDOW RAIL (OR GIRT
FOR VERTICAL SIDING OPTION)
NON-STRUCTURAL HEADER OR WINDOW
RAIL TO POST CONNECTION DETAIL
v Not To Scale
MINIMUM 6' LONG TS NIPPLE
SECURE WITH (4) #12-14x314'
SELF -DRILLING FASTENERS
ITS RAFTER POST
NIPPLE TO 3116'
BASE RAIL %2� r TS CONTINUOUS BASE RAIL
RAFTER POST/
3
BASE RAIL CONNECTION DETAIL
Not To Scale
TS RAFTER
2'x2'x2' 16 GA ANGLE CLIP
SECURE TO POSTAND
RAFTER WITH #12-14 x 314'
SDF's, (2) ON TOP AND
(2) ON SIDE
OR
TS END POST 2'x4' 16 GA PLATE
SECURE TO EACH SIDE OF
POST/RAFTER CONNECTION
WITH (4) #12-14 x 314' SDPs,
(2) ON POST, (2) ON RAFTER
7 END POST/RAFTER CONNECTION DETAIL
Not To Scale
mINIMUM 6' LONG TS NIPPLE
SECURE WITH (4) #12-14 x 3/4'
SELF -DRILLING FASTENERS
NIPPLETO 3116 TSRAFTER POST (CORNER)
BASE RAIL
1-1/2' x 1-1/2' x 2' 16 GA CLIP
ANGLE, SECURE TO RAFTER
POST AND BASE RAIL
WITH (4) #12-14 x 314' SDFs
TS CONTINUOUS BASE RAIL
4 END POST/BASE RAIL CONNECTION DETAIL
Not To Scale
N
2-1/4' FOR
16 GAUGE U-CHANNEL BRACE
12 GA FRAMING
FASTENED TO THE POST AND
2-1/2' FOR
RAFTER, WITH (2) #12-14x 3/4'
14 GA FRAMING
SELF -DRILLING SCREWS AT
EACH END (4 PER BRACE)
BRACE SECTION
Not To Scale
BECHTOL ENGINU D'TESTI
605 WEST NEW YORKA \CE( 'q'j'
DELAND, FLORIDA 3240
Certificate of Authorizgttbn o.
o. 4538
omas Bechto, P.E.—
Florida License o. `
�s • Al�ORION •��; .
AL I�NG\•
PROPOSED UTILITY STRUCTURE
5401 OLD DIXIE HIGHWAY
FORT PIERCE, FLORIDA
ana
revised °"'c 9/17/18
—I BECHTOL ENGINEERING RR/mkb NTS
AND 7F87ING, Inc
caSunoWo GDoiraWx u. o+vsroN4otw. AND Wtvews MMM DMVM ®� RR R'°`�' G18002
dsawa•e•m x4onma� TB SHEET 3 OF 3