HomeMy WebLinkAboutAPPROVED PRODUCTFBC APPROVED PRODUCTS LIST
PRODUCT CATEGORY I SUB CATEGORY
STRUCTURAL COMPONENTS ROOF DECK
STRUCTURAL COMPONENTS I STRUCTURAL WALL
EXTERIOR DOORS
EXTERIOR DOORS
�P 1 WINDOWS
w
FRONT ELEVATION
SCALE: 1/8' =1'
LEFT SIDE ELEVATION
SCALE: 118' =1'
SWINGING
ROLL -UP
SINGLE HUNG
MANUFACTURER
UNION CORRUGATING COMPANY
26 Gauge MasterRib Panel
UNION CORRUGATING COMPANY
26 Gauge MasterRib Panel
THERMA-TRU CORPORATION
•Smoothstar'
ASTA INDUSTRIES INC.
Model 203
MI WINDOWS AND DOORS
Model 185 SH_
& DATE
12/12/17
FL9555.2-R4
12/12/17
FL5891.2
12/12/17
FL8888.1-R5
10/07/17
FL17499.1-R2
12/29/17
]G
O
z
O
LU
o�occ�
m LU IF- t o
CCCCLUCC.�
0-Uca-sJtO�
C)
Z U ® LU
V
LU LU
a- a Ld
Co00
iE ! � Hai ; E O
U
GENERAL NOTES:
1.
THESE PLANS PERTAIN ONLY TO THE STRUCTURE, INCLUDING MAIN WIND FORCE RESISTING SYSTEM, COMPONENTS AND CLADDING, AND BASE RAIL
ANCHORAGE. OTHER DESIGN ISSUES, INCLUDING BUT NOT LIMITED TO PLUMBING, ELECTRICAL, INGRESS/EGRESS, PROPERTY SET -BACKS, FINISH
FLOOR ELEVATIONS AND SLOPES, OR OTHER LOCAL ZONING REQUIREMENTS ARE THE RESPONSIBILITY OF OTHERS.
2.
THESE STRUCTURES ARE DESIGNED AS NON -HABITABLE UTILITY/STORAGE BUILDINGS (RISK CATEGORY 1) CAPABLE OF SUPPORTING DEAD LOAD OF
THE STRUCTURE AND APPLICABLE LIVE AND WIND LOADS. IMPROVEMENTS NOT SPECIFICALLY ADDRESSED HEREIN, INCLUDING DOORS, WINDOWS,
OR OTHER COMPONENTS NOT LISTED IN THE FBC APPROVED PRODUCTS LIST (THIS SHEET), AND NOT PROVIDED AND INSTALLED BY CARPORTS
ANYWHERE, INC., WHICH EXERT ADDITIONAL LOADS ON THE STRUCTURE SHALL BE AT THE OWNER'S RISK. BECHTOL ENGINEERING AND TESTING, INC<j,.,)
SHALL NOT BE RESPONSIBLE FOR STRUCTURAL DAMAGE OR FAILURE DUE TO THE APPLICATION OF ADDITIONAL LOADS:
Q-
3.
ALL COMPONENTS AND CLADDING SHALL BE INSTALLED ACCORDING TO MANUFACTURER'S INSTALLATION INSTRUCTIONS.
o.
n n n
4.
ALL STEEL TUBING SHALL BE 50 KSI GALVANIZED STEEL. ALL FASTENERS SHALL BE GALVANIZED OR STAINLESS STEEL.
CC
t+-
5.
ALL FIELD FRAMING CONNECTIONS SHALL BE #12-14x 1' SELF.DRILLING SCREWS WITHOUT CONTROL SEAL WASHER. ALL SHOP FRAMING
CONNECTIONS SHALL BE WELDED.
®
6.
CONCRETE SHALL HAVE A MINIMUM COMPRESSIVE STRENGTH OF 2500 PSI AT 28 DAYS. THE REINFORCING STEEL SHALL BE MINIMUM GRADE 40.
�
CONCRETE SLAB FOUNDATIONS SHALL BE REINFORCED WITH 6X6=W1 AXW1 .4 WELDED WIRE FABRIC COMPLYING WITH ASTM A 185, OR WITH
0. n L
SYNTHETIC FIBER REINFORCEMENT COMPLYING WITH ASTM C1116.
a
Lm
� �
c�
7.
CONCRETE EXPANSION ANCHORS SHALL BE WEJ-IT ANKR-TITE MODEL AT1252, OR SLEEVE ANCHOR MODEL HSA 1260, OR EQUIVALENT.
8.
POST/RAFTER BRACING: BRACE ON EVERY'POST/RAFTER CONNECTION, EXCEPT FOR END WALLS:
a®a a
C7
9.
SLAB FOUNDATION SUBGRADE SOILS SHALL BE TERMITE TREATED AND COVERED WITH 6 MIL VAPOR RETARDER PER SECTION 11318.1 OF THE FLORIDAa
BUILDING CODE, SIXTH EDITION (2017) - RESIDENTIAL, AND SECTION 1816.1 OF THE FLORIDA BUILDING CODE, SIXTH EDITION (2017) - BUILDING.
-
MINIMUM ALLOWABLE FOUNDATION SOIL CONTACT BEARING PRESSURE OF2,000 PSF IS ASSUMED.
CJ
10.
14 GA FRAMING IS 2-1/2' x 2-1/2' TUBE STEEL (TS). 12 GA FRAMING IS 2=1/4' x 2-1/4' TS.
RIGHT SIDE ELEVATION
SCALE: 1/8' =1' {
0
F-4 "
REAR ELEVATION
SCALE: 118' =1'
NOTE: 14 GA FRAMING.
OCCUPANCY GROUP:
U
CONSTRUCTION TYPE:
11-B
RISK CATEGORY:
I
BUILDING ENCLOSURE TYPE:
ENCLOSED
WIND EXPOSURE CATEGORY:
D
ULTIMATE WIND SPEED (MPH):
165
NOMINAL DESIGN WIND SPEED (MPH):
128
MEAN ROOF HEIGHT (FEET):
19.80
ROOF ANGLE (DEGREES):
9.5
DESIGN PRESSURES (PSF):
ROOF:
ZONE 1:
+16.01-31.4
ZONE 2:
+16:0 / -44.1
ZONE 3:
+16.0 / -69.7
DESIGN ROOF PRESSURES:
+16.01.36.0
WALLS:
ZONE 4:
+32.3 / -352
ZONE 5:
+32.3 / -39.3
DESIGN WALL PRESSURES:
+32.31.36.0
SWINGING DOOR:
+36.11-39.3
ROLL -UP DOOR:
+33.91-37.1
WINDOW:
+37.71-40.9
METAL FRAMING.AND SIDING PREFABRICATED BY
CARPORTS ANYWHERE
P.O. BOX776
STARKE, FL 32091
THESE ENGINEERING DRAWINGS ARE THE PROPERTY OF BECHTOL
ENGINEERING & TESTING, INC. AND CARPORTS ANYWHERE, INC.
THESE DRAWING MAY NOT. BE REPRODUCED WITHOUT THE WRITTEN
CONSENT OF BECHTOL ENGINEERING & TESTING, INC., AND
CARPORTS ANYWHERE, INC.
THIS IS TO CERTIFY THAT THE CALCULATIONS AND SPECIFICATIONS
_HEREIN HAVE BEEN PREPARED BY THE UNDERSIGNED PROFESSIONAL
ENGINEER, AND ARE IN ACCORDANCE WITH THE REQUIREMENTS OF
SECTION 1609 OF THE FLORIDA BUILDING CODE, SIXTH EDITION (2017).
THE PLANS ARE VALID UNTIL THE NEXT REVISION OF THE FLORIDA
BUILDING CODE.
RECEIVED
Q\A BEc/,-. J U N 0 7 2018
BECHTOL ENGINE
605WEST NEINYORKA i4 �\
Sf�LUCIeCOUnty,
DELAND, FLORIDA 32720.'
Certificate of Authoriza8oq�1 15516
•.
�C
_ 41c
LLI -
LU
Tt1ornas B
Florida License No. 3853C- •� �P(E OF
1
��
0, • FLORNv
PROPOSED UTIDTY�0RE ® " ' `'
10197 SOUTH INDIAN RIVER DRIVE
FORT PIERCE, FLORIDA
r'E
414/18
SECHTOL ENGIINEERING NOTED
AND 7ES77N4 lam.G18002TWOGEMEM:QIL EM9bNMEMN. Alb Mh7EAltlS WONG ENGMEEPSu/daamMmB SHEET 1 OF 3
t6 GA. GALVANIZED METAL ROOF PANELS FASTENED
TO PURLINS WITH #12-14 x 3l4' SDFs WITH CONTROL
SEAL WASHER @ AVERAGE 6- O.C. SPACING
FRONT ELEVATION
SCALE: 118' =1'
1' 16 GAUGE FURRING CHANNEL FASTENED TO
EACH RAFTER WITH (2) #12-14 x 3/4' SELF -DRILLING
FASTENER SPACED NOT MORE THAN 48' O.C.
s
3
3
Maximum
s
5
3
r
I
qn'
# 6-
0
4
WELD ALL CHORD
CONNECTIONS,
BOTH SIDES
WELD, CONTINUOUS, ALL SIDES,
TOP AND BOTTOM TRUSS CHORDS
26 GA. GALVANIZED METAL WALL PANELS FASTENED
TO PURLINS WITH #12-14 x 3/4' SDFs WITH CONTROL
12 SEAL WASHER @ AVERAGE 6' O.C. SPACING
O 2
a7 �r m SIDE PURLIN NOTE: R,
Cj
CUT PURLINS AS NECESSARY FOR WINDOWAND DOOR 9 y C5
OPENINGS. ROLL -UP AND SWINGING DOORS REQUIRE L° v
SECTION OF PURLIN ACROSS THE TOP OF OPENING. a m
WINDOWS REQUIRE A SECTION OF PURLIN TOP AND
BOTTOM.
a3
3 t
3
32
TYPICAL INTERIOR POST/TRUSSED RAFTER SECTION
SCALE: 1/8' =1'
6'
4'
Maximum Sq
v,
3
3
20' 3' 1T
LEFT SIDE POST/TRUSSED RAFTER FRAMING PLAN RIGHT SIDE POST/TRUSSED RAFTER FRAMING PLAN
SCALE: 1/8' =1' SCALE: 118' =1'
CONCRETE:
Concrete Shall Have a Minimum Specified Compressive Strength of 2500 PSI at 28 Days
COVER OVER REINFORCING STEEL
r f ndations minimum concrete cover over reinforcing
For ou bars shall be:
3 inches in foundations where the concrete is cast against and permanently in contact with the earth or exposed to the earth or weather, and 1-12 inches elsewhere.
Reinforcing bars embedded in grouted cells shall have a minimum clear distance of 1/4 inch for fine grout or 12 inch for coarse groutbehveen reinforcing bars and any
face of a cell. Reinforcing bars used in masonry walls shall have a masonry cover (including grout) of not less than 2Inches for masonry units with face exposed to earth
or weather 1-1/2 inches for masonry units not exposed to earth or weather.
REINFORCING STEEL:
The reinforcing steel shall be minimum Grade 40.
GALVANIZATION:
Metal accessories for use in exterior wall construction and not directly exposed to the weather shall be galvanized in accordance with ASTM A 153, Class B-2. Metal plate
connectors, screws, bolts and nails exposed directly to the weather shall be stainless steel or hot dipped galvanized.
REINFORCEMENT MAY BE BENT IN THE SHOP OR THE FIELD PROVIDED:
1. All reinforcement is bent cold;
2. The diameter of the bend, measured on the inside of the bar, is not less than sic -bar diameters; and
3. Reinforcement partially embedded in concrete shall not be field bent
REAR ELEVATION
SCALE: 118' =1'
BECHTOL EN(
605 WEST NEW YO
DELAND, FLORIDA
Certificate of Authpd
ENSF
I SIG IflD WNG, I' .
WENVE �• 1
WN x _
F OF
Thomas Bechto�,,W e •, R�OR\pp••
.38. 'r\
Florida LicenseNo538�j_ ,(1_'••.....• \V-�
EXCEPTION:
Where bending is necessary to align dowel bars with a vertical cell, bars partially embedded in concrete shall be permitted to be bent ata slope of not more than 1 inch
of horizontal displacement to 6 inches of vertical bar length.
3/16' WELD, CONTINUOUS,
ALL FOUR SIDES
POST
A
INSTALL 1l2' x 5-11T EXPANSION ANCHOR
THROUGH BASE RAIL WITHIN 6' OF EACH
RAFTER POST ALONG SIDES
MINIMUM 2-1/4' EMBEDMENT
GROUND SURFACE
MONOLITHIC CONC. FOOTING (2500 PSI MIN.)
REINFORCED WITH 2 #Ss CONTINUOUS
CONCRETE MONO. SLAB BASE RAIL ANCHORAGE
1 Not To Scale
TS TRUSSED RAFTER CHORD,
OR NONSTRUCTURAL HEADER
TS END POST OR DOOR/
WINDOW FRAME POST
TS NON-STRUCTURAL HEADER
(12 GA FOR ROLL -UP DOOR FRAME),
BASE RAIL, OR WINDOW RAIL
2'x2'x2' 16 GA ANGLE CLIP
SECURE TO POST (EACH SIDE) AND
RAFTER CHORD/RAIL WITH (4) #12-14x 3/4'
SDF's, (2) ON BOTTOM AND (2) ON SIDE
NOTE: AT ROLL -UP DOOR OPENINGS,
POST SHOULD BE FLUSH WITH RAIL
END. CLIP POST TO RAIL ONLY ON
SIDE OPPOSITE THE OPENING.
POST TO NON-STRUCTURAL HEADER, BASE
RAIL OR WINDOW RAIL CONNECTION DETAIL
5 Not To Scale
TS TRUSSED RAFTER
48' 16 GA U-CHANNEL BRACE
BRACE ANGLE SHALL BE MIN.
45• TO MAX. 60• FROM
HORIZONTAL
DBL TS LEG POST ASSEMBLY
o I v —7
e TS NIPPLES
SECURE POSTS TO
NIPPLES WITH
(4) #12-14 x 314' SDFs
2 RAFTER/LEG ASSEMBLY CONNECTION DETAIL
Not To Scale
TS POST
(12 GA FOR ROLL -UP DOOR FRAME)
2' x 2' x T 16 GA ANGLE CLIP
SECURE TO POST AND TOP OF
HEADER, OR BOTTOM OF WINDOW
RAIUGIRT WITH #12-14x 3/4' SDFs
TS NON-STRUCTURAL HEADER
(12 GA FOR ROLL -UP DOOR FRAME)
TS WINDOW RAIL (OR GIRT
FOR VERTICAL SIDING OPTION)
NON-STRUCTURAL HEADER OR WINDOW
RAIL TO POST CONNECTION DETAIL
V Not To Scale
4' WELD, BOTH SIDES,
TOP, BOTTOM, AND 12' O.C.
SECURE POST TO NIPPLE
WITH (4) #12-14 x 3/4' SDF's
_DBL TS BASE RAIL
RAFTER LEG ASSEMBLY/
DBL. BASE RAIL CONNECTION DETAIL
3 Not To Scale
TS
Tx2'x2' 16 GA ANGLE CLIP
SECURE TO POST AND
RAFTER WITH #12-14 x 3(4'
SDF's, (2) ON TOP AND
(2) ON SIDE
OR
TS END POST 2'x4' 16 GA PLATE
SECURE TO EACH SIDE OF
POSTIRAFTER CONNECTION
WITH (4) #12-14 x 3(4' SDPs,
(2) ON POST, (2) ON RAFTER
END POST/RAFTER CONNECTION DETAIL
� Not To Scale
8' LONG, MINIMUM 14 GA, TS NIPPLE.
SECURE POST TO NIPPLE WITH (4) #12-14x 3W SDFs
TS RAFTER POST (CORNER)
1-112' x 1-1/2' x 2' 16 GA CLIP
/ANGLE, SECURE TO RAFTER
NIPPLE To 311\ s• POST AND BASE RAIL
BASE RAIL �(7�� i i i WITH (4) #12-14 x 3/4' SDF's
TS CONTINUOUS BASE RAIL
4 END POST/BASE RAIL CONNECTION DETAIL
Not To Scale
3116' WELD, BOTH SIDES,
TOP AND BOTTOM
(TYPICAL ALL TRUSS POSTS)
TS POST
3116' WELD, CONTINUOUS,
ALL FOUR SIDES, TOP AND
BOTTOM TRUSS CHORDS
TRUSSED RAFTER CENTER CONNECTION DETAIL
V Not To Scale
1' 16 GAUGE FURRING CHANNEL FASTENED TO EACH
\""�x%I%III11///'/'
\\ P? R H
POST WITH (2) #12-14 x 3/4' SELF -DRILLING FASTENER
,
*
1' 16 GAUGE FURRING CHANNEL FASTENED TO EACH
SPACED NOT MORE THAN 48' O.C.
BECHTOL ENGINE�ItI AWD 1
605 WEST NEW YORK A1T1t '
.••
RAFTER WITH (2) #12-14 x 3/4' SELF-DRIWNG FASTENER SPACED
DELAND, FLORIDA 32 No. 38538
NOT MORE THAN 48' O.C.
Certificate 6
FIN
26 GA. METAL ROOF PANEL
26 GA. METAL WALL PANEL
Thomas Bec ol, P.E. '. /
•.. STATE OF
Florida License No. 38538 \
2-1/4' FOR
ONAL
12 GA FRAMING FASTENED TO THE POST
2-112' FOR RAFTER, WITH (2) #12-14x 3/4'
14 GA FRAMING SELF -DRILLING SCREWS AT
TS RAFTER
TS POST
EACH END (4 PER BRACE)
ROOF PANEL ATTACHMENT
PROPOSED UTILITY STRUCTURE
BRACE SECTION
Not To Scale
10197 SOUTH INDIAN RIVER DRIVE
Not To Scale
WALL PANEL ATTACHMENT
FORT PIERCE, FLORIDA
Not To Scale
BECHTOL ENG/NEERM
mU/ AND TES77NO, Ina
°"1e 4/4/18
o RR
NOTED
RR
G18002
cowsmmo ocorocie+rx. orvosowNWPI. ,vm wiExws nsnxc way