Loading...
HomeMy WebLinkAboutPROJECT INFORMATIONz j aM RiZ IrU O a cn z0 o 0� o °- x 3w In Ld W� mo ARRAY AREA z> ATTIC (IF ROOF -MO 0 ��� �� all BONDED MODULES, OPTIMIZERS, AND RAILS PER UL 2703 J c3a_ ARRAY WIRING CONTINUES, OR oak TRANSITIONS INTO MC CABLE �La OR BUILDING WIRE IN BONDED w METAL RACEWAY WHERE REQUIRED PER [G90.3 I (G)l = O 30A 1- -0N INTERIOR OR EXTERIOR WALL SOLAREDGE 5.OkW 240Vac ADJACENT ac ytq SE5000H-US INVERTER, WITH DISCONNECT � INTEGRAL dN3 I�SCONNECT I[690. a� UNLESS I Sj 10 03 _ REQUIRES) CKT 2 (-) �N CKT2 (+) FL1 XAC z, CKT1 (-) L2 w CKT 1 (+) N ,m GND 0 0 U CONDUCTOR AND RACEWAY SCHEDULE E N � �0 U) zf W a -- W LL 0 J 3 R crn a_ W N �c Z ryj WmJm W x� O Z o� ONE PV MODULE PER SOLAREDGE P300/P320 OPTIMIZER. CIRCUIT I: 8-13 MODULES CIRCUIT 2: 8-13 MODULES TOTAL: 21 MODULES DC SYSTEM SIZE: G090 WDC MAIN FANELBOARD LOCATION (NOT SUITABLE FOR ALL -IN -ONE EXISTING PANELBOARD INTERCONNECTION) 240V I P3W SERVICE CONNECTIONS MADE WITH UTILITY POLARIS IPL CONNECTORS OR SIMILAR O TIER I PV SYSTEM DISCONNECT 240Vac GOA 3R ENCLOSURE AC DISCONNECT FUSED AT 30A MCB n Li ^ EXISTING TI LOADS SYMBOL CIRCUIT 310.15(B) AMPACITY TEMPERATURE RACEWAY FILL ADJUSTED AMPACITY REQUIRED AMPAWY SETS MATERIAL INSULATION RACEWAY SIZE (AWG) QTY CONDUCTOR I -WAY RUN VOLTAGE - DROP O PV MODULE WIRING 40A 55-C(0.76) 30.4A (Iscx 1.25) I CU 600V PV FREE AIR, 12 I D+ ImP@28VDC: (INTEGRATED BY MANUFACTURER) wA 12.0A <30.4A SUPPORTED I DC-' 25 0.31% O PV OPTIMIZER DC OUTPUT CIRCUIT 40A 55°C (0.7G) WA 30.4A (Imaz) 15A I CU 600V PV FREE AIR 12 I D+ 3, [350VJ < 30.4A SUPPORTED I DG 0.05% O PV DC OUTPUT CIRCUIT WIRING 40A 55°C(0.76) 30.4A'* Amax) I CU 600VPV FREE AIR 12 I-2 DC± 3CV WA 15A < 30.4A SUPPORTED 0 .551% 10 1 BARE G OD PV DC OUTPUT CIRCUIT WIPING 35A 55°C (0.67) 18.8A Qmax) I CU THWN 3/4' METAL [350VI Q5°C) 0.8 I5A < 18.8A (BONDED) 10 I-2 DC- 100, I.06% 10 1 G O INVERTER OUTPUT CIRCUIT 35A (75°C) 45°C (0.82) 1.0 29A (75°C) (Imaxx 1.25) 21 A 1.25 29A I CU THWN 3/4' 10 2 N 30 [24OVI x < 0.68% 10 1 G OELECTRIC POWER PRODUCTION 65A (75°C) q5°C (0.87) 65A I230.79(D)I 3/4' EMT 6 2 L AS SHORT AS 1240V,101 SOURCE CONDUCTORS 75A(90°C) (75°C) [230.42(B)] I CU THWp1_2 (BONDED) 8 1 N POSSIBLE 0.097. © GROUNDING ELECTRODE CONDUCTOR WA WA WA wA I cu BARE PVC OR 6, OR PER I GEC AS SHORT AS WA .* 0 NO [250.GGI POSSIBLE 02 GO C RATED TERMINALS, OR TERMINALS WITHOUT A LABELED RATING, MAY NOT BE USED. 0 z' 0o o2 SEAL 00 Z W� Z U Q 7 2W WW Uv,� T;�l S`' ' � f).•'1 ' / 00 Ln L 3 I tT REV. I DATE I REVISION DESCRIPTION 00 2018-04-12 INITIAL RELEASE Dull I CHK I APP Dc I DC I DC 0690000 esa RENE W,AB L E S 4155 St Johns Pkwy, Ste 1100 Sanford, FL 32111 40i.268.6455 INSTALLATION REQUIREMENTS: CONTRACTOR TO VERIFY FIELD CONDITIONS AND REPORT DISCREPANCIES TO ENGINEER. MANUFACTURER -PROVIDED INSTRUCTIONS AND TORQUE REQUIREMENTS TO BE FOLLOWED FOR ALL LISTED EQUIPMENT. ALL WORK TO BE DONE IN ACCORDANCE WITH THE NATIONAL ELECTRICAL CODE 2014 AND ANY LOCAL AHJ OR UTILITY REQUIREMENTS. ARRAY AND STRUCTURE GROUNDING: ALL MODULES, OPTIMIZERS, AND RAILS TO BE BONDED USING UL 2703 LISTED HARDWARE. RAILS BONDED TO # 10 (MIN.) BARE COPPER GROUNDING WIRE USING BURNDY WEED-LUG-G.7 OR OTHER MANUFACTURER -APPROVED LISTED HARDWARE. MODULE SPECIFICATIONS: Hyundai H15-5290RG Pmp 29OW; Vmp 32.OV; Imp 9. 1 A; Voc 38.8V; 15c 9.7A; Max Fuse 20A TC5: Pmp-0.420/o/°C, Voc-0.30%/°C SIMILAR 280-295W UL LISTED MODULES MAY BE SUBSTITUTED UPON OWNER'S APPROVAL. J Min. Module Operating Voltage: (Vmp @55°C) > � 32.0 x (I - 0.0042 x +30°) = 28.OV Max. Module Voltage: (lowest temp O°C) G 35.5 x (I - 0.0030 x -25°) = 41.7V OPTIMIZER OPERATING RANGE: 8-48V (ok) EXISTING AC SCOPE OF WORK:_ -- -----GROUNDING - A PV SYSTEM COMPRISED OF HYUNDAI MODULES AND A ELECTRODE 501AREDGE SE5000H-U5 INVERTER. INTERCONNECTION TO OCCUR VIA SUPPLY-SIDE CONNECTION (E 10 1) OR LOAD -SIDE CONNECTION (E 102), AS DETERMINED BY INSTALLER BASED ON 51TE CONDITIONS. Engineer: David K Click, PE FBPE: #14642 FL GOA: *31310 FL CILB: GVC 56919 NABCEP PVIP: 0041104-08 INTERCONNECTION REQUIREMENTS: INVERTER INTERCONNECTION SHALL BE DONE IN A MANNER PROHIBITING THE BACKFEED OF A GENERATOR. DRAWING LIST: E 101 : THREE LINE DIAGRAM (SUPPLY SIDE) E 102: THREE LINE DIAGRAM (LOAD SIDE) E 103: LABELING REQUIREMENTS CLIENT NAME: Barnes Residence SGALE NT5 ADDRESS: 2110 Oak Drive, Fort Pierce, FL, 34949 PROJECT NAME: FORMAT II' x 11' HYUNDAI / 6E5000 PV SYSTEM DRAWING N° PV SYSTEM SIZE: 609OWDC STC / 5000WAG CONTINUOUS SHEET TITLE: E101 THREE LINE DIAGRAM (SUPPLY SIDE) DATE 2018-04-12 w z a� �3 wz OV Z Z 0 O OiL o iL 3N Zw W0 rn w :3is ww mo 6 8C o°d w w U g�w N O ,m [/ q Z ay w0 0z 0 ww � :3w zw w0 xZ 0 0 U a� �X N O mZ O -- - - Ed- w, Vi]� wl: L2 0 J �3 cc:) a =w- W (j Z fN W J w �Z �w o� 0 U0 zE Z Z 00 WF o ix SEAL 00 �a W ok 3 � U �a Z� ww V� gn_ F3 ARRAY AREA ATTIC (IF ROOF -MOUNTED) ARRAY WIRING CONTINUES, OR TRANSITIONS INTO MC CABLE OR BUILDING WIRE IN BONDED METAL RACEWAY WHERE REQUIRED PER [G90.31 (G)l INTERIOR OR EXTEKI CONDUCTOR AND RACEWAY 5CHEDULE -------------- ------------- + - + _ + _ + _ + _ + _ ONE PV MODULE PER 50LAREDGE P300/P320 rill, OPTIMIZER. CIRCUIT I : 8-13 MODULES CIRCUIT 2: 8-13 MODULES L. TOTAL: 21 MODULES DC 5Y5TEM SIZE: G090 WDC I +_ +_ +_ +_ +_ +- I I I B --------------------------------� BONDED MODULES, OPTIMIZERS, AND RAIL5 PER UL 2703 EXISTING MLO EXISTING PANELBOARD, 240V I P3W SERVICE 1 20/24OVac SEE NOTES POP INTERCONNECTION REQUIREMENTS 30A ADJACENT ac 50LAREDGE 5.OkW 240Vac DISCONNECT 5E5000H-U5 INVERTER, WITH (OPTIONAL, INTEGRAL do DISCONNECT UNLESS [G90. 1 51 (N3 P) REQUIRES) CKT 2 CKT 2 (+) CKT 1 (-) - V 3oA LZ CKT 1 (+) AC ry E INSTALLATION REQUIREMENTS: CONTRACTOR TO VERIFY FIELD CONDITIONS AND REPORT DISCREPANCIES TO ENGINEER. MANUFACTURER -PROVIDED INSTRUCTIONS AND TORQUE REQUIREMENT5 TO BE FOLLOWED FOR ALL L15TED EQUIPMENT. ALL WORK TO BE DONE IN ACCORDANCE WITH THE NATIONAL ELECTRICAL CODE 2014 AND ANY LOCAL AHJ OR UTILITY REQUIREMENTS. ARRAY AND 5TKUCTURE GROUNDING: ALL MODULES, OPTIMIZEK5, AND RAILS TO BE BONDED U51NG UL 2703 L15TED HARDWARE. RAILS BONDED TO # 10 (MIN.) BARE COPPER GROUNDING WIRE U51NG BUKNDY WEEB-LUG-G.7 OR OTHER MANUFACTURER -APPROVED L15TED HARDWARE. MODULE SPECIFICATIONS: Hyundai H15-5290PG Pmp 29OW; Vmp 32.OV; Imp 9. 1 A; Voc 38.8V; 15c 9.7A; Max Fuse 20A TC5: Pmp-0.420/o/°C, Voc-0.300/oiC 51MILAR 280-295W UL L15TED MODULES MAY BE SUBSTITUTED UPON OWNERS APPROVAL. MCa Min. Module Operating Voltage: (Vmp @55°C) " 1-2 32.0 x (I - 0.0042 x +30°) = 28.OV y o Max. Module Voltage: (lowest temp O°C) J 36.8 x (.I - 0.0030 x -25°) = 41 .7V ""o � OPTIMIZER OPERATING RANGE: 8-48V (ok) 5COPE OF WORK: 5YMBOL CIRCUIT 310.15(B) AMPACITY TEMPERATURE RACEWAY FILL ADJU5TED AMPACITY REQUIRED AMPACITY SETS MATERIAL INSULATION RACEWAY 51ZE(AWG) QTY CONDUCTOR i-WAY RUN _ VOLTAGE DROP O PV MODULE WIRING 40A 55°C (0.7G) 30.4A (15cx 1.25) I CU 600VPV FREE AIR, 12 I DC+ Imp@28VDC: (INTEGRATED BY MANUFACTURER) WA 12.OA<30.4A 5UPPORTED I DC- 2'S 0.31% BO---P-V-OP-TIMIZER-DC-OUTPUT-CIRCUIT ---_.40A - - 55-C(0.76) WA 30.4A- (Imax) _ 15A < 30.49 _I— GU —600V-PV FREE AIR, — 12 1 DC+ 3, [350V) SUPPORTED I DG 0.05% O PV DC OUTPUT CIRCUIT 1MRING 40A 55°C (0.76) 30.4A" (Imp I GU 600V PV FREEAIR, 12 12 1-2 1-2 DC- 30 [350VI WA 15A < 30AA SUPPORTED 10 I BAC- 0.51% OD PV DC OUTPUT CIRCUIT MKING 35A 55°C (0.67) 18.8A A10 (Imax) I CU THWN 314° METAL 10 12 t DC- 100 [350VI (75°C) 0.8 15A < I5.8A (BONDED) I.OG% 10 1 G O INVERTER OUTPUT CIRCUIT 35A (75°C) 45°C (0.82) 29A (75C) (Imax x 1.2T 21Ax1.25 < CU TNWN 3/4, 10 10 2 N 30'[240V]1.0 0 I G 0.68% -- 6U'( KAI CD I EKMINALS, UK I LKMINALS WI I HUUI A LAbr-LED RATING, MAY NOT BE USED: REV. I DATE I REVISION DESCRIPTION I DRW I CHK I APP 00 2018-04-12 INITIAL FELEASE DC Dc DC LEXI5TING A PV SYSTEM COMPRISED OF HYUNDAI MODULES AND A 50LAKEDGE 5E5000H-U5 INVERTER. INTERCONNECTION TO OCCUR VIA 5UPPLY-5IDE CONNECTION (E 10 1) OK LOAD-51DE CONNECTION (E 102), EXISTING AC A5 DETERMINED BY INSTALLER BASED ON SITE CONDITION5. GROUNDING ELECTRODE INTERCONNECTION REQUIREMENT5: _ LOAD-51DE IN5TALLATION5 SHALL MEET [705. 1 2(D)] FOR PANELBOARD [3U513AR AND SUPPLIED CONDUCTOR. ACCOUNT FOR LOADING FROM EXISTING PV 5Y5TEM: [UTILITY BREAKER + PV 13REAKER51 <_ [(BUS RATING) x 1 20%] 4155 5t Johns Pkwy,_Ste 1100 Safford, FL 32111 401.268.6455 Engineer: David K Click, PE FBPE: i14642 FL GOA: 031310 FL CIL5: GVC 56919 NABCEP PVIP: 1041104-08 INVERTER BREAKER TO BE PLACED AT OPPOSITE END OF BU515AK FROM UTILITY SUPPLY BREAKER. INVERTER INTERCONNECTION 5HALL BE DONE IN A MANNER PROHIBITING THE BACKFEED OF A GENERATOR. DRAWING LIST: ` E 101 : THREE LINE DIAGRAM (SUPPLY 51DE) E 102: THREE LINE DIAGRAM (LOAD SIDE) E 103: LABELING REQUIREMENTS CLIENT NAME: Barnes Residence ADDRESS: 2110 Oak Drive, Fort Pierce, FL, 34949 PROJECT NAME: H"'UNDAI / 5E5000 PV 5%'FEM PV SYSTEM SIZE: 6090WDC 5TC / 5000WAC CONTINUOUS SHEET TITLE: THREE LINE DIAGRAM (LOAD 51DE) SCALE NT5 FORMAT II' x 11' DRAWING N° E102 DATE 2016-04-12 C U Wz Z LM W3 W Z �>u '0a aZ Z 2 N o� 0CL o C- 3w U3 zW Uj cnw o� W W mo z; Ra 0 TZWW s� E_ J 0 M q P oz x_ a ,„ 10 03 0 W W �N :3 W Z0 �Z �Z ~ U Z W w� 0 J W 3 az 0z a= Z y W J cr W �Z W 0 N � W 0 00 Z N Z Z 00 W� o� 2ZZ o� U �_ a �w W W :3 _ 0 0 ME r- 3 ALL LABELS TO COMPLY WITH [FFPC] OR [2014 NEC 110.21(B)] AS APPLICABLE, LABELS SHALL BE OF SUFFICIENT DURABILITY TO WITHSTAND THE ENVIRONMENT INVOLVED. AT EACH DC JUNCTION BOX: (690.35(F)] LABEL THE DC CONDUCTORS OF THIS PHOTOVOI=T UNGROUNDED AND MAY BE EN ALONG INDOOR/OUTDOOR EXPOSED DC WIRING AT (MAX.) 10' INTERVALS: [690.3 I (G)] AND FFPC 1 1. 12.2. 1.3.21 PHOTOVOLTAIC POWER SOURCE AT DC DISCONNECT: (690. l 51 DC DISCONNECT LABEL SOLAR DC DISCONNECT AT INVFRTFR: [690.531 PV POWER SOURCE DC RATING RATED CURRENT AT MAXIMUM POWER: 1 7.4A RATED VOLTAGE AT MAXIMUM POWER: 350V MAXIMUM SYSTEM VOLTAGE: 500V MAXIMUM SYSTEM CURRENT: 30A "CONTRACTOR TO MODIFY TO MATCH FIELD CONDITIONS" - - ----RATED GURREN-T-=-(ST-C—ARRAY-RATING-) / 35OV - MAXIMUM SYSTEM CURRENT = 1 5A x-(# DC INPUT CIRCUITS) AT AC DISCONNECTS: (690. 151 SOLAR AC DISCONNECT AT PV INTERCONNECTION POINT: [690.541 PV POWER SOURCE AC RATING RATED CURRENT: 2 1 A RATED VOLTAGE: 240V AT MOST ACCESSIBLE PV SYSTEM AC DISCONNECT, AND AT UTILITY SERVICE DISCONNECT: (705. 101 DISCONNECT LOCATIONS SYSTEM SPECIFIC. COULD INCLUDE EITHER CLEAR TEXT DESCRIPTION OR A MAP OF 51TE DESCRIBING LOCATIONS OF BOTH DISCONNECTS: 1) UTILITY SERVICE DISCONNECT AND 2) PV SYSTEM DISCONNECT y. &;-k.LACAKD5 REQUIRED IF DISCONNECTS ARE NOT CO -LOCATED) AT EXTERIOR MAIN PV DISCONNECT: (2014 690. 121 RAPID SHUTDOWN DISCONNECT PHOTOVOLTAIC SYSTEM EQUIPPED WITH RAPID SHUTDOWN (This plaque or directory shall be reflective, with all letters capitalized and having a minimum height of 3/8", in white on red background.) PHOTOVOLTAIC DISCONNECT (This plague or label shall have contrasting color with capital letters at least 3/8" in height and in a nonserif font) WARNING: PHOTOVOLTAIC POWER SOURCE (This plague/label shall be reflective red, with white capital letters at least 3/4" in height and in a nonserif font) PV INSTALLER INFORMATION 51GNAGE PER FFPC 1 1. 1 2.2. 1 .5 REV. DATE REVISION DE5CRPTION DRW C-K APP 00 2018-04-12 INITIAL RELEASE DC Dc Dc (DOOOOOO esa R ENE W A B L E S 4155 St Johns Pkwy, Ste 1100 Sanford, FL 32111 401268.6455 Engineer: David K Click, PE FBPE: 014642 FL COA: *31310 FL CILB: CVC %919 NABCEP PVIP: 0041104-06 F APPLICABLE) AT BACKFED BREAKER IN CUSTOMER EQUIPMENT: [705. 1 2(D)(3)]: SIMILAR LABEL TO DUAL POWER SOURCES: BUILDING SERVED BY UTILITY SERVICE AND PHOTOVOLTAIC SYSTEM AT EACH PANELBOARD UPSTREAM OF PV INVERTER BREAKER. [705. 1 2(D)(2)(3)(b)]: IF A LOAD -SIDE CONNECTION AND THE SUM OF SOURCES EXCEEDS THE BUSBAK RATING, THE PV * UTILITY SUPPLY BREAKERS SHALL BE LOCATED AT OPPOSITE ENDS OF THE BUS WITH THIS LABEL NEAR THE PV INVERTER BREAKER (EQUIVALENT WORDING ACCEPTABLE): WARNING INVERTER OUTPUT CONNECTION DO NOT RELOCATE THIS OVERCURKENT DEVICE COLOR CODING: DC+: RED OR ORANGE DC-: BLACK OR BLUE GROUND: GREEN OR BARE AC L 1: BLACK; L2: RED; N: WHITE OR GREY DRAWING LIST: E 101 : THREE LINE DIAGRAM (SUPPLY SIDE) E 102: THREE LINE DIAGRAM (LOAD SIDE) E 103: LABELING REQUIREMENTS CLIENT NAME: Barnes Residence ADDRESS: 2110 Oak Drive, Fort Pierce, FL, 34949 PROJECT NAME: H'rUNDA 1 / 5E5QQQ PV 5 'FEM PV SYSTEM SIZE: 6090WDC STC / 5000WAC CONTINUOUS SHEET TITLE: LA5E-ING REQUIREMENT5 SCALE NT5 FORMAT II' x 11' DRAWING K E103 DATE 2018-04-12