Address: 5304 OAKLAND LAKE CIR, FORT
Permit Number: 1804-0587
PIERCE, FL 34951
Permit Type: BUILDING
t �ewprvperty Qafa)
RESIDENTIAL (SFR UP TO 2
PaR•aeo: 131 r00000388008
Job Description: CONSTRUCTION OF A NEW
FLOORS)
SINGLE FAMILY HOME; 3/2/21 STORY. TOTAL
NumberiUnits: 1
sub&id.n:
SQ FT. 2466.
Block
Lot 22
Status: Pending
✓oduffcU : orY
Zoning: PLANNED UNIT
DEVELOPMENT
Date Applied: 4/19/2018
PERMIT REVIEW INFORMATION
Reviewed By
Date Started
Date Sent Department
Date Completed
Review Type
Review Status
Rodriguezdi
4/19/2018
4/19/2018
DOCUMENTS MISSING
INCOMPLETE
durdenw
5/16/2018
5/16/2016
PLANS EXAMINER REVIEW
INCOMPLETE
Rodriguezdi
4/19/2018
4/19/2018
4/19/2018
FRONT COUNTER REVIEW
COMPLETE
bended
4/27/2018
4/25/2018
4/27/2018
.ADDRESSING ASSIGNMENT
COMPLETE
swarizell
4/25/2018
4/19/2018
5/3/2018
ENVIRONMENTAL REVIEW
COMPLETE
angela
4/25/2018
4/19/2018
5/17/2018
ZONING REVIEW
COMPLETE
PERMIT REVIEW COMMENTS INFORMATION
Compliance Comment
Review Type
Comment
Date Date
PLANS
• PLEASE ADD THE CUBIC VOLUME OF THE CONDITIONED SPACE TO INFORMATION BLOCK
EXAMINER
5/1712018
CONTAINING THE SQUARE FOOT INFORMATION OR A LETTER FROM THE DESIGN PROFESSIONAL
REVIEW
SPECIFYING THE CUBIC VOLUME OF THE CONDITIONED SPACE. SEE CHAPTER 1 SECTION 107 OF THE
2017 FLORIDA BUILDING CODE.
PLANS
SUBMITTED PLANS ARE NOT SITE SPECIFIC. PLEASE SUBMIT THE PLANS WITH THE SECTIONS THAT
EXAMINER
511712018
ARE NOT SITE SPECIFIC STRUCK THROUGH OR SPECIFIED DO NOT USE. PLANS MUST BE CORRECTED
REVIEW
BY THE DESIGN PROFESSIONAL IN CHARGE. PLEASE SEE SECTION 107 OF THE 2017 FLORIDA
BUILDING CODE.
PLANS
SUBMITTED PRODUCTAPPROVAL FOR THE ROOFING MATERIAL WAS ONLY THE INFORMATION PAGE.
EXAMINER
5/17/2018
PLEASE SUBMIT THE INSTALLATION. INSTRUCTIONS AS WELL. SEE SECTION 107 OF THE 2017 FLORIDA
REVIEW
BUILDING CODE.
PLANS
EXAMINER
5/17/2018
• PLEASE SHOW FLAME SPREAD INDEX AND SMOKE DEVELOPED INDEX FOR WALLAND CEILING
REVIEW
FINISHES IN ACCORDANCE WITH SECTION 302.9 OF THE 2017 FLORIDA RESIDENTIAL CODE.
PLANS
EXAMINER
5/17/2018
• PLEASE SHOW THE FLAME SPREAD AND SMOKE DEVELOPED INDEX FOR THE INSULATION AS
REVIEW
REQUIRED IN SECTION 302.10 OF THE 2017 FLORIDA RESIDENTIAL CODE.
PLANS
EXAMINER
5/17/2018
PLEASE ADD TO THE PLANS THE CLIMATIC AND GEOGRAPHIC DESIGN CRIERIA WEATHERING AND
REVIEW
TERMITE AREA IN ACCORDANCE WITH TABLE 301.2.(1)
ZONING
THE SURVEY SHOWS THE A/C PAD AT THE REAR OF THE PROPERTY; HOWEVER, THE FLOOR PLAN
REVIEW
5/17/2018 4/25/2018
SHOWS THE PAD ON THE SIDE WHICH HAS A DRAINAGE EASEMENT. NOTHING CAN ENCROACH INTO A
DRAINAGE EASEMENT. PLEASE CORRECT SUREYS OR FLOOR PLAN:
ZONING
REVIEW
4/25/2018 4/25/2018
COMMENTS E-MAILED TO CONTRACTOR 4/2511S.
Inspector
Inspection Type
Name
ADDRESS FINAL
SEWER CONNECT
BLOWER DOOR TEST
MECHANICAL DUCT LEAKAGE
COMPACTION TEST - ORIGINAL
- TURN INTO OFFICE
prmit Status Lookup
INSPECTION INFORMATION
Date Date Inspection Date of Scheduled
Updated Scheduled Status Inspection By
Permit . Inspector
Number Comments
1804-0587
1804-0587
1804-0587
1804-0587
1804-0587
1804-0587
http://codeinspectionpublic.stlucieco.2ov/Pennit Status'.asbx
5/17/2018