HomeMy WebLinkAboutENERGY EFFICIENCY CODESCANNED
FORM 405-10 stbi :IP'r110
FLORIDA ENERGY EFFICIENCYII CODE FOR BUILDING CONSTRUCTION
Florida Department of Business and Professional Regulation - Residential Performance Method
Project Name: Westcott
Builder Name: Maronda Homes
Street: a S 3 0 PA R a e a `J -
Permit Office:
City, State, Zip: 'F Pl- • t?' e-c r, F1,
Permit Number:
Owner: Z 4 $,-14
Jurisdiction:
Design Location: FL, Fort Pierce
1. New construction or existing New (From Pla s)
9. Wall Types (3478.7 sqft.)
Insulation Area
2. Single family or multiple family Single-family
a. Frame - Wood, Exterior
R=13.0 1640.00 ft2
b. Concrete Block - Int Insul, Exterior
R=4.1 1404.70 ft2
3. Number of units, if multiple family 1
c. Frame - Wood, Adjacent
R=13.0 434.00 ft2
4. Number of Bedrooms 6
d. N/A
R= ft2
10. Ceiling Types (2355.0 sqft.)
Insulation Area
5. Is this a worst case? Yes
a. Under Attic (Vented)
R=30.0 2355.00 ft2
6. Conditioned floor area above grade (ft2) 3901
b. N/A
R= ft2
c. N/A
R= ft2 .
Conditioned floor area below grade (ft2) 0
11. Ducts
R ft
7. Windows(368.2 sqft.) Description Area
a. Sup: Attic, Ret: Attic, AH: RoomslnBlock2 6 431.25
a. U-Factor: Dbl, U=0.56 368.18 ft2
b. Sup: Attic, Ret: Attic, AH: RoomslnBlock2 6 543.75
SHGC: SHGC=0.35
b. U-Factor: N/A ft2
12. Cooling systems
kBtu/hr 'Efficiency
a. Central Unit
30.0 SEER:14.00
SHGC:
b. Central Unit
34.0 SEER:14.50
c. U-Factor. N/A ft2
SHGC:
13. Heating systems
kBtu/hr Efficiency
d. U-Factor: N/A ft2
a. Electric Heat Pump
30.0 HSPF:7.80
SHGC:
b. Electric Heat Pump
34.0 HSPF:8.20
Area Weighted Average Overhang Depth: 1.145 ft.
Area Weighted Average SHGC: 0.350
14. Hot water systems
a. Electric
Cap: 66 gallons
8. Floor Types (4710.0 sqft.) Insulation Area
EF:0.880
a. Floor Over Other Space R=0.0 2355.00 ft2
b. Conservation features
b. Slab -On -Grade Edge Insulation R=0.0 725:00"ft2- -
None
c. other (see details) R= 630.00 ft2
15. Credits
Pstat
0.094 TotalJProposed Modified Loads: 52.34
PASS
Glass/Floor Area:
Total Standard Reference Loads: 77.69
i
I hereby certify that the plans and specifications covered by
Review of the plans and""�qT
this calculation are in compliance with the Flor'da Energy
specifications covered by this
Code.
calculation indicates complianceii�°�
with the Florida Energy Code.
PREPARED BY:
DATE: I1 06
Before construction.is completed
this building will be inspected for
compliance with Section 553.908
I hereby certify that this building, as s ' mpliance
Florida Statutes.
C�b�
with the Florida Energy Code.
OWNER/AGENT:
BUILDING OFFICIAL:_
DATE: 3 I
DATE:'
- Compliance requires certificafion by the air handler unit manufacturer that the air handler ericlo '
qualifies as certified factory -sealed in accordance with 403.2.2.1.1. a=
- Compliance requires completion of a Florida Air Barrier and Insulation Inspection Checklist n
2/6/2013 3:13 PM EriergyGauge® USA - FlaRes2010 Section 405.4.1 Compliant Software
h
Page 1 of 6
I PROJECT
Title:
Westcott
Bedrooms) 6
Address Type: Street Address
Building Type:
FLProp2010
Conditioned Area: 3901
Lot #
Owner:
Total Stores: 2
Block/SubDivision:
# of Units:
1
Worst Case: Yes
PlatBook:
Builder Name:
Maronda Homes
Rotate Ai gle: 0
Street:
Permit Office:
Cross Ventilation: No
County: ST. LUCIE
Jurisdiction:
Whole House Fan: No
City, State, Zip:
Family Type:
Single-family
FL,
New/Existing:
New (From Plans)
Comment:
I CLIMATE
IECC Design Temp
Int Design Temp Heating Design Daily Temp
Design Location
TMY Site Zone 97.5 % 2.5 %
Winter
Summer Degree Days Moisture
Range
FL, Fort Pierce FL_ST LUCIE_CO_INTL I 2 39 90
70
75 722 62
Low
I BLOCKS
Number
Name
Area Volume
1
Block1
1726 116051.7998
2
Block2
2175 17400
SPACES
Number
Name
Area Volume Kitchen Occupants
Bedrooms
InfilID Finished Cooled
Heated
1
RoomslnBlock1
1726 16051.7998 Yes 2.65470392 1
1 Yes Yes
Yes
2
RoomslnBlock2
2175 17400 No 3.34529607 5
2 Yes Yes
Yes
I FLOORS
#
Floor Type
Space I Perimeter Perimeter R-Value
Area
Joist R-Value Tile Wood
Carpet
1 Floor over Garage
RoomslnBlo)k2 __ ___
630 ft2
11 0 0
1
2 Slab -On -Grade Edge Insulatio RoomslnBlock1 150.5 ft 0
1725 ft2
0.3 0
0.7
3 Floor Over Other Space
RoomslnBl Ick2 — __--
2355 ft2
0 0.3 0
0.7
I ROOF
/
Roof Gable Roof
Solar
SA Emitt Emitt Deck Pitch
V #
Type
Materials Area Area Color
Absor.
Tested Tested Insul. (deg)
1
Gable or Shed Composition shinglejl 2482 f12 392 ft2 Medium
0.96
No 0.9 No 0
18.4
I ATTIC
V #
Type
Ventilation Vent Ratio (1 in)
Area
RBS IRCC
1
Full attic
Vented 300 2355 ft2
N N
I
2/6/2013 3:13 PM EnergyGauge® USA - FlaRes2010 Section 405.4.1 Compliant Software Page 2 of 6
I CEILING
#
Ceiling Type
Space
R-Value
Area
Framing Frac
Truss Type
1
Under Attic (Vented)
RoomslnBlock2
30
2355 ft2
0.11
Wood
I
WALLS
Adjacent
I Cavity
Width
Height
Sheathing
Framing Solar
Below
Space
1 N
Exterior
Frame - Wood
RoomslnBloc
13
48
6
8 0
388 ft2
0
0.23 0.6
0
2 N
Exterior
Concrete Block - Int
InsRoomslnBloc
4.1
44
6
9 4
415.3333
0
0 0.6
0
3 E.
Exterior
Frame - Wood
RoomslnBloc
13
54
0
8 0
432 ft2
0
0.23 0.6
0
Int
InsRooms1nBloc
4.1
54
0
9 4
504 ft2
0
0 0.6
0
4 E
Exterior
Concrete Block -
5 S
Exterior
Frame - Wood
RoomslnB ioc
13
48
6
8 0
388 ft2
0
0.23 0.6
0
6 S
Exterior
Concrete Block- Int
InsRoomslnBi c
4.1
26
0
9 4
242.6666
0
0 0.6
0
7 W
Exterior
Frame - Wood
RoomslnBloc
13
54
0
8 0
432 ft2
0
0.23 0.6
0
8 W
Exterior
Concrete Block - Int
InsEgoomslnBlloc
4.1
26
0
9 4
242.6666
0
0 0.6
0
9 -
Garage
Frame - Wood
RoomslnBloc
13
28
0
9 4
261.3333
0
0.23 0.01
0
10 -
Garage
Frame - Wood
RoomslnBloc
13
18
6
9 4
172.6666
0
0.23 0.01
0
DOORS
#
Omt
Door Type
Space l
Storms U-Value
Width
Height
Area
Ft
In
Ft In
1
W
Insulated
RoomslnBloc
None
0.39
3
0
6 8
20 ft2
2
-
Wood
RoomslnBloc
None
0.39
3
0
6 8 16.66666
f
WINDOWS
Orientation shown is,the entered orientation => changed to Worst Case.
Wall
Overhang
#
Omt ID
Frame Panes
NFRC U-Factor SHGC
Storms Area
Depth
Separation
Int Shade
Screening
1
E 3
Metal Low-E Double
Yes
0.56
0.35
N
60 ft2
1 ft 0 in
0 ft 10 in
HERS 2006
None
2
E 3
Metal Low-E Double
Yos
0.56
0.35
N
15 ft2
1 ft 0 in
0 ft 10 in
HERS 2006
None
3
E 4
Metal Low-E Double
Yes
0.56
0.35
N
4 ft2
1 ft 0 in
11 ft 4 in
HERS 2006
None
4
E 4
Metal Low-E Double
Yes
0.56
0.35
N
9.76 ft2
1 ft 0 in
11 ft 4 in
HERS 2006
None
5
E 4
Metal Low-E Double
Yes
0.56
0.35
N
18.4 1`12
1 ft 0 in
13 ft 0 in
HERS 2006
None
6
E 4
Metal Low-E Double
Yes
0.56
0.35
N
23.19 ft2
1 ft 0 in
11 ft 4 in
HERS 2006
None
7
E 4
Metal Low-E Double
Yes
0.56
0.35
N
48 ft2
1 ft 0 in
11 ft 4 in
HERS 2006
None
8
S 5
Metal Low-E Double
Yes
0.56
0.35
N
15 ft2
1 ft 0 in
0 ft 10 in
HERS 2006
None
9
W 7
Metal Low-E Double
Yes
0.56
0.35
N
75 ft2'
1 ft 0 in
1 ft 0 in
HERS 2006
None
10
W 7
Metal Low-E Double
IYes
0.56
0.35
N
34 ft2
1 ft 0 in
4 ft 0 in
HERS 2006
None
11
W 8
Metal Low-E Double
J'Yes
0.56
0.35
N
52.6 ft2
1 ft 0 in
11 ft 4 in
HERS 2006
None
12
W 8
Metal Low-E Double
! Yes
I
0.56
0.35
N
13.33333 5 ft 0 in
2 ft 4 in
HERS 2006
None
2/6/2013 3:13 PM EnergyGauge® USA - FlaRes2010 Section 405.4.1 Compliant Software Page 3 of 6
I GARAGE
#
Floor Area Ceiling Area Exposed Wall Perimeter . Avg. Wall Height Exposed Wall Insulation
1
630 ft2
0 ft2 I 50.5 ft 9.3 ft 3
INFILTRATION
# Scope
Method
SLA CalM 50 ELA EgLA ACH ACH 50
1 BySpaces
2 BySpaces
Proposed SLA
Proposed SLA
0.000360 11 29.8 89.475 168.27 0.3235 6.0921
0.000360 2053.8 112.75 212.04 0.3235 7.0821
HEATING SYSTEM
I
#
System Type
Subtype Efficiency Capacity Block
Ducts
1
2
Electric Heat Pump
Electric Heat Pump
None HSPF: 7.8 30 kBtu/hr 1
None HSPF: 8.2 34 kBtu/hr 2
sys#1
sys#2
COOLING SYSTEM
#
System Type
Subtype Efficiency Capacity Air Flow SHR Block
Ducts
1
2
Central Unit
Central Unit
Split I SEER: 14 30 kBtu/hr 900 cfm 0.75 1
Split I SEER: 14.5 34 kBtu/hr 1020 cfm 0.75 2
sys#1
sys#2
I HOT WATER SYSTEM
#
System Type SubType
Location EF Cap Use SetPnt Conservation
1
Electric None
Garagei 0.88 66 gal 90 gal 120 deg None
SOLAR HOT WATER SYSTEM
I
FSEC
Cert # Company Name
Collector Storage
System Model # Collector Model # Area Volume
FEF
None
None
I ft2
DUCTS
1
#
--- Supply --
Location R-Value Area
L Return-- Air Percent
Location Area Leakage Type Handler CFM 25 Leakage QN RLF
HVAC #
Heat Cool
1
2
Attic 6 431.25
Attic 6 543.75
Attic 86.25 ft DSE=0.88 RoomslnBI 0.0 cfm 0.00 % 0.00 0.60
Attic 108.75 DSE=0.88 RoomslnBI 0.0 cfm 0.00 % 0.00 0.60
1 1
2 2
1
2/6/2013 3:13 PM EnergyGauge® USA - FlaRes2010 Section 405.4.1 Compliant Software Page 4 of 6
i
l
TEMPERATURES
I
Programable Thermostat: Y
Ceiling Fans:
Cooling X� Jan
Jan
VI Feb
[X] Feb
[[X] Mar
[X] Mar
Apr
f APr
f
May
May f X
Jun
Jun
[X] Jul
[X] Jul
Aug
E Augf
Sep
Sep
Oct
Oct
Nov
Nov
Dec
X Dec
tX]
Ventin [X] Jan
Venting
[[�X]] Feb
[[�X]] Mar
[X] A r
[
May [X]
Jun
[X] Jul
[ Aug
[
Se
Oct
Nov
[X] Dec
Thermostat Schedule:
HERS 2006
Reference
Hours
Schedule Type
1
2
3
14
5
6
7
8
9
10
11
12
Cooling (WD)
AM
PM
78
80
78
80
78
78
78
78
78
78
78
78
78
78
78
78
80
78
80
78
80
78
80
78
Cooling (WEH)
AM
PM
78
78
78
78
78
78
78
78
78
78
78
78
78
78
78
78
78
78
78
78
78
78
78
78
Heating (WD)
AM
PM
66
68
66
68
66
68
66
68
66
68
68
68
68
68
68
68
68
68
68
68
68
66
68
66
Heating (WEH)
AM.
PM
66
68
66
68
66
68
66
68
66
68
68
68
68
68
68
68
68
68
68
68
68
66
68
66
i
2/6/2013 3:13 PM EnergyGauge® USA - FlaRes2010 Section 405.4.1 Compliant Software Page 5 of 6
FORM 405-10
Florida Code Compliance Checklist
Florida Department of Business and Professional Regulations
Residential Whole Building Performance Method
ADDRESS: I PERMIT #:
FL,
MANDATORY REQUIREMENTS SUMMARY - See individual code sections for full details.
COMPONENT
SECTION
SUMMARY OF REQUIREMENT(S)
CHECK
Air leakage
402.4
To be caulked,Igasketed, weatherstripped or otherwise sealed.
Recessed lighting IC -rated as meeting ASTM E 283. Windows and
doors = 0.30 cfm/sq.ft. Testing or visual inspection required. Fireplaces:
gasketed door, s & outdoor combustion air. Must complete envelope
leakage report or visually verify Table 402.4.2.
Thermostat &
403.1
At least one tI6rmostat shall be provided for each separate heating and
controls
cooling system. Where forced -air furnace is primary system,
programmable thermostat is required. Heat pumps with supplemental
electric heat must prevent supplemental heat when compressor can
meet the load.
Ducts
403.2.2
All ducts, airi handlers, filter boxes and building cavities which form the
primary air containment passageways for air distribution systems shall
be considered ducts or plenum chambers, shall be constructed and
sealed in accordance with Section 503.2.7.2 of this code.
403.3.3
Building framing cavities shall not be used as supply ducts.
Water heaters
403.4
Heat trap required for vertical pipe risers. Comply with efficiencies in
Table 403 .14.3.2. Provide switch or clearly marked circuit breaker
(electric) or shutoff (gas). Circulating system pipes insulated to = R-2
+ accessible manual OFF switch.
Mechanical
403.5
Homes designed to operate at positive pressure or with mechanical
ventilation
ventilation, systems shall not exceed the minimum ASHRAE 62 level.
No makeup air from attics, crawlspaces, garages or outdoors adjacent
to pools or spas.
Swimming Pools
403.9
Pool pumps and pool pump motors with a total horsepower (HP) of = 1
& Spas
HP shalll'have the capability of operating at two or more speeds. Spas
and heated pools must have vapor -retardant covers or a liquid cover or
other means proven to reduce heat loss except if 70% of heat from
site -recovered energy. Off/timer switch required. Gas heaters minimum
thermal; efficiency=78% (82% after 4/16/13). Heat pump pool heaters
minimum COP= 4.0.
Cooling/heating
403.6
Sizing calculation performed & attached. Minimum efficiencies per
Tables!503.2.3. Equipment efficiency verification required. Special
equipment
occasion cooling or heating capacity requires separate system or
variable capacity system. Electric heat >10kW must be divided into two
or more stages.
Ceilings/knee walls
405.2.1
R-19 space permitting.
2/6/2013 3:13 PM EnergyGauge® USA - FlaRes2010 Section 405.4.1 Compliant Software Page 6 of 6
r
ENERGY PERFO
DISP
1ANCE LEVEL (EPL)
Y CARD
ESTIMATED ENERGY PERFORMANCE INDEX* = 67
The lower the EnergyPerforrnance Index, the more efficient the home.
1. New construction or existing
2. Single family or multiple family
3. Number of units, if multiple family
4. Number of Bedrooms
5. Is this a worst case?
6. Conditioned floor area (ft2)
7. Windows" Description
a. U-Factor: Dbl, U=0.56
SHGC: SHGC=0.35
b. U-Factor: N/A
SHGC:
c. U-Factor: N/A
SHGC:
d. U-Factor: N/A
SHGC:
Area Weighted Average Overhang Depth:
Area Weighted Average SHGC:
8. Floor Types
a. Floor Over Other Space .
b. Slab -On -Grade Edge Insulation
c. other (see details)
New (From Plans)
Single-family
1
6
Yes .
3901
Area
368.18 ft2
ft2
ft2
ft2
1.145 ft.
0.350
Insulation
Area
R=0.0
2355.00 ft2
R=0.0
1725.00 ft2
R=
630.00 ft2
I certify that this home has complied with the Florida I
Construction through the above energy saving feature
in this home before final inspection. rwi , a
based on installed Code complia
Builder Signature:
Address of New Home: M4dew o d
, , FL,
9. Wall Types
Insulation
Area
a. Frame - Wood, Exterior
R=13.0
1640.00 ft2
b. Concrete Block - Int Insul, Exterior
R=4.1
1404.70 ft2
c. Frame - Wood, Adjacent
R=13.0
434.00 ft2
d. N/A
R=
ft2
10. Ceiling Types
Insulation
Area
a. Under Attic (Vented)
R=30.0
2355.00 ft2
b. N/A
R=
ft2
c. N/A
R=
ft2
11. Ducts
R ft2
a. Sup: Attic, Ret: Attic, AH: RoomslnBlock2
6 431.25
b. Sup: Attic, Ret: Attic, AH: RoomslnBlock2
6 543.75
12. Cooling systems
a. Central Unit
b. Central Unit
13. Heating systems
a. Electric Heat Pump
b. Electric Heat Pump
14. Hot water systems
a. Electric
b. Conservation features
None
15. Credits
/ Efficiency Code for Building
ch will be installed (or exceeded)
Display Card will be completed
Date: to
City/FL Zip:
kBtu/hr Efficiency
30.0 SEER:14.00
34.0 SEER:14.50
kBtu/hr Efficiency
30.0 HSPF:7.80
34.0 HSPF:8.20
Cap: 66 gallons
EF: 0.88
Pstat
*Note: This is not a Building Energy Rating. If your index is below 70, your home may qualify for energy efficient
mortgage (EEM) incentives if you obtain a Florida EnergyGauge Rating. Contact the EnergyGauge Hotline at (321)
638-1492 or see the EnergyGauge web site at energygauge.com for information and a Est of certified Raters. For
information about the Florida Building Code, Energy Conservation, contact the Florida Building Commission's support
staff. i
**Label required by Section 303.1.3 of the Florida Building Code, Energy Conservation, if not DEFAULT.
EnergyGauge® USA J FlaRes2010 Section 405.4.1 Compliant Software