HomeMy WebLinkAboutENERGY EFFICIENCY CODESCANNED FORM 405-10 stbi :IP'r110 FLORIDA ENERGY EFFICIENCYII CODE FOR BUILDING CONSTRUCTION Florida Department of Business and Professional Regulation - Residential Performance Method Project Name: Westcott Builder Name: Maronda Homes Street: a S 3 0 PA R a e a `J - Permit Office: City, State, Zip: 'F Pl- • t?' e-c r, F1, Permit Number: Owner: Z 4 $,-14 Jurisdiction: Design Location: FL, Fort Pierce 1. New construction or existing New (From Pla s) 9. Wall Types (3478.7 sqft.) Insulation Area 2. Single family or multiple family Single-family a. Frame - Wood, Exterior R=13.0 1640.00 ft2 b. Concrete Block - Int Insul, Exterior R=4.1 1404.70 ft2 3. Number of units, if multiple family 1 c. Frame - Wood, Adjacent R=13.0 434.00 ft2 4. Number of Bedrooms 6 d. N/A R= ft2 10. Ceiling Types (2355.0 sqft.) Insulation Area 5. Is this a worst case? Yes a. Under Attic (Vented) R=30.0 2355.00 ft2 6. Conditioned floor area above grade (ft2) 3901 b. N/A R= ft2 c. N/A R= ft2 . Conditioned floor area below grade (ft2) 0 11. Ducts R ft 7. Windows(368.2 sqft.) Description Area a. Sup: Attic, Ret: Attic, AH: RoomslnBlock2 6 431.25 a. U-Factor: Dbl, U=0.56 368.18 ft2 b. Sup: Attic, Ret: Attic, AH: RoomslnBlock2 6 543.75 SHGC: SHGC=0.35 b. U-Factor: N/A ft2 12. Cooling systems kBtu/hr 'Efficiency a. Central Unit 30.0 SEER:14.00 SHGC: b. Central Unit 34.0 SEER:14.50 c. U-Factor. N/A ft2 SHGC: 13. Heating systems kBtu/hr Efficiency d. U-Factor: N/A ft2 a. Electric Heat Pump 30.0 HSPF:7.80 SHGC: b. Electric Heat Pump 34.0 HSPF:8.20 Area Weighted Average Overhang Depth: 1.145 ft. Area Weighted Average SHGC: 0.350 14. Hot water systems a. Electric Cap: 66 gallons 8. Floor Types (4710.0 sqft.) Insulation Area EF:0.880 a. Floor Over Other Space R=0.0 2355.00 ft2 b. Conservation features b. Slab -On -Grade Edge Insulation R=0.0 725:00"ft2- - None c. other (see details) R= 630.00 ft2 15. Credits Pstat 0.094 TotalJProposed Modified Loads: 52.34 PASS Glass/Floor Area: Total Standard Reference Loads: 77.69 i I hereby certify that the plans and specifications covered by Review of the plans and""�qT this calculation are in compliance with the Flor'da Energy specifications covered by this Code. calculation indicates complianceii�°� with the Florida Energy Code. PREPARED BY: DATE: I1 06 Before construction.is completed this building will be inspected for compliance with Section 553.908 I hereby certify that this building, as s ' mpliance Florida Statutes. C�b� with the Florida Energy Code. OWNER/AGENT: BUILDING OFFICIAL:_ DATE: 3 I DATE:' - Compliance requires certificafion by the air handler unit manufacturer that the air handler ericlo ' qualifies as certified factory -sealed in accordance with 403.2.2.1.1. a= - Compliance requires completion of a Florida Air Barrier and Insulation Inspection Checklist n 2/6/2013 3:13 PM EriergyGauge® USA - FlaRes2010 Section 405.4.1 Compliant Software h Page 1 of 6 I PROJECT Title: Westcott Bedrooms) 6 Address Type: Street Address Building Type: FLProp2010 Conditioned Area: 3901 Lot # Owner: Total Stores: 2 Block/SubDivision: # of Units: 1 Worst Case: Yes PlatBook: Builder Name: Maronda Homes Rotate Ai gle: 0 Street: Permit Office: Cross Ventilation: No County: ST. LUCIE Jurisdiction: Whole House Fan: No City, State, Zip: Family Type: Single-family FL, New/Existing: New (From Plans) Comment: I CLIMATE IECC Design Temp Int Design Temp Heating Design Daily Temp Design Location TMY Site Zone 97.5 % 2.5 % Winter Summer Degree Days Moisture Range FL, Fort Pierce FL_ST LUCIE_CO_INTL I 2 39 90 70 75 722 62 Low I BLOCKS Number Name Area Volume 1 Block1 1726 116051.7998 2 Block2 2175 17400 SPACES Number Name Area Volume Kitchen Occupants Bedrooms InfilID Finished Cooled Heated 1 RoomslnBlock1 1726 16051.7998 Yes 2.65470392 1 1 Yes Yes Yes 2 RoomslnBlock2 2175 17400 No 3.34529607 5 2 Yes Yes Yes I FLOORS # Floor Type Space I Perimeter Perimeter R-Value Area Joist R-Value Tile Wood Carpet 1 Floor over Garage RoomslnBlo)k2 __ ___ 630 ft2 11 0 0 1 2 Slab -On -Grade Edge Insulatio RoomslnBlock1 150.5 ft 0 1725 ft2 0.3 0 0.7 3 Floor Over Other Space RoomslnBl Ick2 — __-- 2355 ft2 0 0.3 0 0.7 I ROOF / Roof Gable Roof Solar SA Emitt Emitt Deck Pitch V # Type Materials Area Area Color Absor. Tested Tested Insul. (deg) 1 Gable or Shed Composition shinglejl 2482 f12 392 ft2 Medium 0.96 No 0.9 No 0 18.4 I ATTIC V # Type Ventilation Vent Ratio (1 in) Area RBS IRCC 1 Full attic Vented 300 2355 ft2 N N I 2/6/2013 3:13 PM EnergyGauge® USA - FlaRes2010 Section 405.4.1 Compliant Software Page 2 of 6 I CEILING # Ceiling Type Space R-Value Area Framing Frac Truss Type 1 Under Attic (Vented) RoomslnBlock2 30 2355 ft2 0.11 Wood I WALLS Adjacent I Cavity Width Height Sheathing Framing Solar Below Space 1 N Exterior Frame - Wood RoomslnBloc 13 48 6 8 0 388 ft2 0 0.23 0.6 0 2 N Exterior Concrete Block - Int InsRoomslnBloc 4.1 44 6 9 4 415.3333 0 0 0.6 0 3 E. Exterior Frame - Wood RoomslnBloc 13 54 0 8 0 432 ft2 0 0.23 0.6 0 Int InsRooms1nBloc 4.1 54 0 9 4 504 ft2 0 0 0.6 0 4 E Exterior Concrete Block - 5 S Exterior Frame - Wood RoomslnB ioc 13 48 6 8 0 388 ft2 0 0.23 0.6 0 6 S Exterior Concrete Block- Int InsRoomslnBi c 4.1 26 0 9 4 242.6666 0 0 0.6 0 7 W Exterior Frame - Wood RoomslnBloc 13 54 0 8 0 432 ft2 0 0.23 0.6 0 8 W Exterior Concrete Block - Int InsEgoomslnBlloc 4.1 26 0 9 4 242.6666 0 0 0.6 0 9 - Garage Frame - Wood RoomslnBloc 13 28 0 9 4 261.3333 0 0.23 0.01 0 10 - Garage Frame - Wood RoomslnBloc 13 18 6 9 4 172.6666 0 0.23 0.01 0 DOORS # Omt Door Type Space l Storms U-Value Width Height Area Ft In Ft In 1 W Insulated RoomslnBloc None 0.39 3 0 6 8 20 ft2 2 - Wood RoomslnBloc None 0.39 3 0 6 8 16.66666 f WINDOWS Orientation shown is,the entered orientation => changed to Worst Case. Wall Overhang # Omt ID Frame Panes NFRC U-Factor SHGC Storms Area Depth Separation Int Shade Screening 1 E 3 Metal Low-E Double Yes 0.56 0.35 N 60 ft2 1 ft 0 in 0 ft 10 in HERS 2006 None 2 E 3 Metal Low-E Double Yos 0.56 0.35 N 15 ft2 1 ft 0 in 0 ft 10 in HERS 2006 None 3 E 4 Metal Low-E Double Yes 0.56 0.35 N 4 ft2 1 ft 0 in 11 ft 4 in HERS 2006 None 4 E 4 Metal Low-E Double Yes 0.56 0.35 N 9.76 ft2 1 ft 0 in 11 ft 4 in HERS 2006 None 5 E 4 Metal Low-E Double Yes 0.56 0.35 N 18.4 1`12 1 ft 0 in 13 ft 0 in HERS 2006 None 6 E 4 Metal Low-E Double Yes 0.56 0.35 N 23.19 ft2 1 ft 0 in 11 ft 4 in HERS 2006 None 7 E 4 Metal Low-E Double Yes 0.56 0.35 N 48 ft2 1 ft 0 in 11 ft 4 in HERS 2006 None 8 S 5 Metal Low-E Double Yes 0.56 0.35 N 15 ft2 1 ft 0 in 0 ft 10 in HERS 2006 None 9 W 7 Metal Low-E Double Yes 0.56 0.35 N 75 ft2' 1 ft 0 in 1 ft 0 in HERS 2006 None 10 W 7 Metal Low-E Double IYes 0.56 0.35 N 34 ft2 1 ft 0 in 4 ft 0 in HERS 2006 None 11 W 8 Metal Low-E Double J'Yes 0.56 0.35 N 52.6 ft2 1 ft 0 in 11 ft 4 in HERS 2006 None 12 W 8 Metal Low-E Double ! Yes I 0.56 0.35 N 13.33333 5 ft 0 in 2 ft 4 in HERS 2006 None 2/6/2013 3:13 PM EnergyGauge® USA - FlaRes2010 Section 405.4.1 Compliant Software Page 3 of 6 I GARAGE # Floor Area Ceiling Area Exposed Wall Perimeter . Avg. Wall Height Exposed Wall Insulation 1 630 ft2 0 ft2 I 50.5 ft 9.3 ft 3 INFILTRATION # Scope Method SLA CalM 50 ELA EgLA ACH ACH 50 1 BySpaces 2 BySpaces Proposed SLA Proposed SLA 0.000360 11 29.8 89.475 168.27 0.3235 6.0921 0.000360 2053.8 112.75 212.04 0.3235 7.0821 HEATING SYSTEM I # System Type Subtype Efficiency Capacity Block Ducts 1 2 Electric Heat Pump Electric Heat Pump None HSPF: 7.8 30 kBtu/hr 1 None HSPF: 8.2 34 kBtu/hr 2 sys#1 sys#2 COOLING SYSTEM # System Type Subtype Efficiency Capacity Air Flow SHR Block Ducts 1 2 Central Unit Central Unit Split I SEER: 14 30 kBtu/hr 900 cfm 0.75 1 Split I SEER: 14.5 34 kBtu/hr 1020 cfm 0.75 2 sys#1 sys#2 I HOT WATER SYSTEM # System Type SubType Location EF Cap Use SetPnt Conservation 1 Electric None Garagei 0.88 66 gal 90 gal 120 deg None SOLAR HOT WATER SYSTEM I FSEC Cert # Company Name Collector Storage System Model # Collector Model # Area Volume FEF None None I ft2 DUCTS 1 # --- Supply -- Location R-Value Area L Return-- Air Percent Location Area Leakage Type Handler CFM 25 Leakage QN RLF HVAC # Heat Cool 1 2 Attic 6 431.25 Attic 6 543.75 Attic 86.25 ft DSE=0.88 RoomslnBI 0.0 cfm 0.00 % 0.00 0.60 Attic 108.75 DSE=0.88 RoomslnBI 0.0 cfm 0.00 % 0.00 0.60 1 1 2 2 1 2/6/2013 3:13 PM EnergyGauge® USA - FlaRes2010 Section 405.4.1 Compliant Software Page 4 of 6 i l TEMPERATURES I Programable Thermostat: Y Ceiling Fans: Cooling X� Jan Jan VI Feb [X] Feb [[X] Mar [X] Mar Apr f APr f May May f X Jun Jun [X] Jul [X] Jul Aug E Augf Sep Sep Oct Oct Nov Nov Dec X Dec tX] Ventin [X] Jan Venting [[�X]] Feb [[�X]] Mar [X] A r [ May [X] Jun [X] Jul [ Aug [ Se Oct Nov [X] Dec Thermostat Schedule: HERS 2006 Reference Hours Schedule Type 1 2 3 14 5 6 7 8 9 10 11 12 Cooling (WD) AM PM 78 80 78 80 78 78 78 78 78 78 78 78 78 78 78 78 80 78 80 78 80 78 80 78 Cooling (WEH) AM PM 78 78 78 78 78 78 78 78 78 78 78 78 78 78 78 78 78 78 78 78 78 78 78 78 Heating (WD) AM PM 66 68 66 68 66 68 66 68 66 68 68 68 68 68 68 68 68 68 68 68 68 66 68 66 Heating (WEH) AM. PM 66 68 66 68 66 68 66 68 66 68 68 68 68 68 68 68 68 68 68 68 68 66 68 66 i 2/6/2013 3:13 PM EnergyGauge® USA - FlaRes2010 Section 405.4.1 Compliant Software Page 5 of 6 FORM 405-10 Florida Code Compliance Checklist Florida Department of Business and Professional Regulations Residential Whole Building Performance Method ADDRESS: I PERMIT #: FL, MANDATORY REQUIREMENTS SUMMARY - See individual code sections for full details. COMPONENT SECTION SUMMARY OF REQUIREMENT(S) CHECK Air leakage 402.4 To be caulked,Igasketed, weatherstripped or otherwise sealed. Recessed lighting IC -rated as meeting ASTM E 283. Windows and doors = 0.30 cfm/sq.ft. Testing or visual inspection required. Fireplaces: gasketed door, s & outdoor combustion air. Must complete envelope leakage report or visually verify Table 402.4.2. Thermostat & 403.1 At least one tI6rmostat shall be provided for each separate heating and controls cooling system. Where forced -air furnace is primary system, programmable thermostat is required. Heat pumps with supplemental electric heat must prevent supplemental heat when compressor can meet the load. Ducts 403.2.2 All ducts, airi handlers, filter boxes and building cavities which form the primary air containment passageways for air distribution systems shall be considered ducts or plenum chambers, shall be constructed and sealed in accordance with Section 503.2.7.2 of this code. 403.3.3 Building framing cavities shall not be used as supply ducts. Water heaters 403.4 Heat trap required for vertical pipe risers. Comply with efficiencies in Table 403 .14.3.2. Provide switch or clearly marked circuit breaker (electric) or shutoff (gas). Circulating system pipes insulated to = R-2 + accessible manual OFF switch. Mechanical 403.5 Homes designed to operate at positive pressure or with mechanical ventilation ventilation, systems shall not exceed the minimum ASHRAE 62 level. No makeup air from attics, crawlspaces, garages or outdoors adjacent to pools or spas. Swimming Pools 403.9 Pool pumps and pool pump motors with a total horsepower (HP) of = 1 & Spas HP shalll'have the capability of operating at two or more speeds. Spas and heated pools must have vapor -retardant covers or a liquid cover or other means proven to reduce heat loss except if 70% of heat from site -recovered energy. Off/timer switch required. Gas heaters minimum thermal; efficiency=78% (82% after 4/16/13). Heat pump pool heaters minimum COP= 4.0. Cooling/heating 403.6 Sizing calculation performed & attached. Minimum efficiencies per Tables!503.2.3. Equipment efficiency verification required. Special equipment occasion cooling or heating capacity requires separate system or variable capacity system. Electric heat >10kW must be divided into two or more stages. Ceilings/knee walls 405.2.1 R-19 space permitting. 2/6/2013 3:13 PM EnergyGauge® USA - FlaRes2010 Section 405.4.1 Compliant Software Page 6 of 6 r ENERGY PERFO DISP 1ANCE LEVEL (EPL) Y CARD ESTIMATED ENERGY PERFORMANCE INDEX* = 67 The lower the EnergyPerforrnance Index, the more efficient the home. 1. New construction or existing 2. Single family or multiple family 3. Number of units, if multiple family 4. Number of Bedrooms 5. Is this a worst case? 6. Conditioned floor area (ft2) 7. Windows" Description a. U-Factor: Dbl, U=0.56 SHGC: SHGC=0.35 b. U-Factor: N/A SHGC: c. U-Factor: N/A SHGC: d. U-Factor: N/A SHGC: Area Weighted Average Overhang Depth: Area Weighted Average SHGC: 8. Floor Types a. Floor Over Other Space . b. Slab -On -Grade Edge Insulation c. other (see details) New (From Plans) Single-family 1 6 Yes . 3901 Area 368.18 ft2 ft2 ft2 ft2 1.145 ft. 0.350 Insulation Area R=0.0 2355.00 ft2 R=0.0 1725.00 ft2 R= 630.00 ft2 I certify that this home has complied with the Florida I Construction through the above energy saving feature in this home before final inspection. rwi , a based on installed Code complia Builder Signature: Address of New Home: M4dew o d , , FL, 9. Wall Types Insulation Area a. Frame - Wood, Exterior R=13.0 1640.00 ft2 b. Concrete Block - Int Insul, Exterior R=4.1 1404.70 ft2 c. Frame - Wood, Adjacent R=13.0 434.00 ft2 d. N/A R= ft2 10. Ceiling Types Insulation Area a. Under Attic (Vented) R=30.0 2355.00 ft2 b. N/A R= ft2 c. N/A R= ft2 11. Ducts R ft2 a. Sup: Attic, Ret: Attic, AH: RoomslnBlock2 6 431.25 b. Sup: Attic, Ret: Attic, AH: RoomslnBlock2 6 543.75 12. Cooling systems a. Central Unit b. Central Unit 13. Heating systems a. Electric Heat Pump b. Electric Heat Pump 14. Hot water systems a. Electric b. Conservation features None 15. Credits / Efficiency Code for Building ch will be installed (or exceeded) Display Card will be completed Date: to City/FL Zip: kBtu/hr Efficiency 30.0 SEER:14.00 34.0 SEER:14.50 kBtu/hr Efficiency 30.0 HSPF:7.80 34.0 HSPF:8.20 Cap: 66 gallons EF: 0.88 Pstat *Note: This is not a Building Energy Rating. If your index is below 70, your home may qualify for energy efficient mortgage (EEM) incentives if you obtain a Florida EnergyGauge Rating. Contact the EnergyGauge Hotline at (321) 638-1492 or see the EnergyGauge web site at energygauge.com for information and a Est of certified Raters. For information about the Florida Building Code, Energy Conservation, contact the Florida Building Commission's support staff. i **Label required by Section 303.1.3 of the Florida Building Code, Energy Conservation, if not DEFAULT. EnergyGauge® USA J FlaRes2010 Section 405.4.1 Compliant Software