HomeMy WebLinkAboutENERGY EFFICIENCY CODE & PROJECT INFORMATIONFORM R405-2017
FLORIDA ENERGY EFFICIENCY
Florida Department of Business and Profe
Project Name: SEDONA DEVELOPMENT 3136-3145
Street: 3135-3148 ILLUSION CIRCLE�NNE
City, State, Zip: FT. PIERCE, FL,
��° '�
Owner.,
Design Location: FL, Fort Pierce St 8
1. New construction or existing
2. Single family or multiple family
3. Number of units, If multiple family
4. Number of Bedrooms
5. Is this a worst case?
6. Conditioned floor area above grade (ftz)
Conditioned floor area below grade (ftz)
7. Windows(390.0 sgft.) Description
a. U-Factor: Dbl, U=0.65
SHGC: SHGC=0.25
b. U-Factor. Dbl, U=0.60
SHGC: SHGC=0.25
c. U-Factor. N/A
SHGC:
d. U-Factor. WA
SHGC:
Area Weighted Average Overhang Depth:
Area Weighted Average SHGC:
8. Floor Types (4044.0 sgft.)
a. Slab -On -Grade Edge Insulation
b. N/A
c. N/A
New (From Plans)
Multi -family
6
12
No
4044
Area
240.00 ftz
150.00 ftz
ftz
ftz
1.000 ft.
0.250
Insulation Area
R=0.0 4044.00 ftz
R= ftz
R= ftz
DE FOR BUILDING CONSTRUCTION
al Regulation - Residential Performance Method
Builder Name:
Permit Office: ST. LUCIE COUNTY
Permit Number.
Jurisdiction:
County: St. Lucie (Florida Clir
9. Wall Types (6420.0 sqft.)
a. Concrete Block - Int Insul, Exterior
b. N/A
c. WA
d. N/A
10. Ceiling Types (4046.0 sgft.)
a. Under Attic (Vented)
b. N/A
c. N/A
11. Ducts
3 additional duct system(s)
b. Sup: Attic, Ret: Attic, AH: UNIT 1
c. Sup: Attic, Rat: Attic, AH: UNIT 1
12. Cooling systems
a. Central Unit
b. Central Unit
3 additional cooling systems
13. Heating systems
a. Electric Strip Heat
b. Electric Strip Heat
3 additional heating systems
14. Hot water systems
a. Electric
b. Conservation features
None
15. Credits
OCT 19 2018
Insulation Area
R=4.1 6420.00 ftz
R= ftz
R= ftz
R= ftz
Insulation Area
R=30.0 4046.00 ftz
R= ftz
R= ftz
R ftz
6 135
6 135
(see detail
kBtu/hr Efficiency
18.8 SEER:16.00
18.8 SEER:16.00
(see details)
kBtu/hr Efficiency
17.0 COP:1.00
17.0 COP:1.00
(see details)
Cap: 40 gallons
EF: 0.950
CF, Pstat
Glass/Floor Area: 0.096 Total Proposed Modified '' .oads: 148.80 PASS I
Total Baseline Loads: 157.99
I hereby certify that the plans and specifications covered by
this calculation are in compliance with the Florida Energy
Code. - _ ,.•
. ,4 « i► ri -
I hereby certify that this building, as ed,, is in mpliance
with the Florida Energy Code. /
OWNER/AGENII:
DATE:
iew, of the plans and
:ifications covered by this
ulation indicates compliance
the Florida Energy Code.
ire construction is completed
building will be inspected for
ipliance with Section 553.908
ida Statutes.
TE:
NG OFFICIAL:
- Compliance requires certification by the air handler unit manufacturer that the air handler enclosure qualifies as
certified factory -sealed In accordance with R403.3.2.1.
- Compliance requires an Air Barrier and Insulation Inspection Checklist in accordance with R402.4.1.1 and this project requires an
envelope leakage test report with envelope leakage no greater than 7.00 ACH50 (R402.4.1.2).
File Copy
I
10/171201811:44 AM EnergyGaugeO USA Section R40I.4.1 Compliant Software Page 1 of 6
i
FORM R405-2017 INPIIT AlIMMARV [_ldFiP_I[I ICT RFPn12T
- ---- -- - - — - — — -- — --
P�OJECT
—
Title: SEDONA DEVELOPMENT 3
Bedrooms: I 12
Address Type:
Street Address
Building Type: User
Conditioned A a: 40"
Lot #
Owner Name:
Total Stories: 1
Block/Subdivision:
# of Units: 6
Worst Case: No
PlatBook:
Builder Name:
Rotate Angle: 0
Street:
3135-3145 ILLUSION
C
Permit Office: ST. LUCIE COUNTY
Cross Ventilation: No
County:
St. Lucie
Jurisdiction:
Whole House F n: No
City, State, Zip:
FT. PIERCE,
Family Type: Multi -family
FL,
New/Existing: New (From Plans)
Comment:
CLIMATE
i
/
Design Temp
Int Design Temp Heating Design Daily Temp
V Design Location TMY Site 97.5 % 2.5 %
Winter
Summer Degree Days Moisture
Range
FL, Fort Pierce FI- VERO_BEACH MUNI I 39 90
70
75 299
62
Low
BLOCKS
Number Name Area
Volume
1 Block1 688
6880
2 Block2 667
6670
3 Block3 667
6670
4 Block4 1334 13340
5 Block5 688
6880
SPACES
i
Number Name Area
Volume Kitchen Occupants
Bedrooms
Infll ID Finished Cooled
Heated
1 UNIT 1 688
6880 Yes 2
2
1 Yes
Yes
Yes
2 UNIT 2 667
6670 No 2
2
1 Yes
Yes
Yes
3 UNIT 3 667
6670 No 2
2
1 Yes
Yes
Yes
4 UNIT 4 AND 5 1334
13340 No 2
4
1 Yes
Yes
Yes
5 UNIT 6 688
6880 No 2
2
1 Yes
Yes
Yes
FLOORS
i
# Floor Type Space Perimeter Perimeter R Value
Area
Joist R-Value
Tile Wood
Carpet
1 Slab -On -Grade Edge Insulatio
UNIT 1 125 ft 0
688 ft2
1 0
0
2 Slab -On -Grade Edge Insulatio
UNIT 2 125 ft �I 0
667 ft2
....
0 0
1
3 Slab -On -Grade Edge Insulatio
UNIT 3 125 ft it 0
667 ft2
----
1 0
0
4 Slab -On -Grade Edge Insulatio UNIT 4 AND 5 250 ft I 0
1334 ft2
----
1 0
0
5 Slab -On -Grade Edge Insulatlo
UNIT 6 125 ft II 0
688 ft2
----
1 0
0
I
10/17/2018 11:44 AM I
EnergyGauge® USA Section R40I5.4.1 Compliant Software Page 2 of 6
FORM R405-2017 INPUT AUMMARV r_NFf:KI ICT RpDADT
(ROOF
/
Roof
Gable
Roof Solar SA
Emitt
Emitt
Deck
Pitch
V
#
Type Materials Area
Area
Color Absor.
Tested
Tested
Insul.
(deg)
1
Gable or shed Composition shingles 4380 ftz
�42 ftz
Light 0.6
No
0.9
No
0
22.6
ATTIC
v
#
Type Ventilation
Ven� Ratio (1 In)
Area
RBS
IRCC
1
Full attic Vented
1300
4044 ftz
N
N
OILING
#
Ceiling Type Space
R-Value
Ins Type
Area
Framing Frac Truss Type
1
Under Attic (Vented) UNIT 1
30II
Blown
688 ft2
0.11
Wood
2
Under Attic (Vented) UNIT 1
30
Blown
668 ft2
0.11
Wood
3
Under Attic (Vented) UNIT 1
3Q
Blown
668 ftz
0.11
Wood
4
Under Attic (Vented) UNIT 1
30
Blown
1334 ftz
0.11
Wood
5
Under Attic (Vented) UNIT 1
30I
Blown
688 ftz
0.11
Wood
WALLS
Adjacent Space
Cavity I Width
_
Height
Sheathing Framing
_
Solar
Below
1
N
Exterior Concrete Block - Int Insul UNIT 1
4.1 16
10
160.0 ftz
0
0
0.5
0
-2
E
Exterior Concrete Block - Int Insul UNIT 1
4.1 45
10
450.0 ftz
0
0
0.5
0
3
S
Exterior Concrete Block - Int Insul UNIT 1
4.1 16
10
160.0 ftz
0
0
0.5
0
4
W
Exterior Concrete Block - Int Insul UNIT 1
4.1 45
10
450.0 ftz
0
0
0.5
0
5
N
Exterior Concrete Block - Int Insul UNIT 2
4.1 16
10
160.0 ftz
0
0
0.5
0
-6
E
Exterior Concrete Block - Int Insul UNIT 2
4.1 45
10
450.0 ftz
0
0
0.5
0
-7
S
Exterior Concrete Block - Int Insul UNIT 2
4.1 16
10
160.0 ft2
0
0
0.5
0
_ 8
E
Exterior Concrete Block - Int Insul UNIT 2
4.1 45
10
450.0 ftz
0
0
0.5
0
_ 9
N
Exterior Concrete Block - Int Insul UNIT 3
4.1 16
10
160.0 ftz
0
0
0.6
0
_ 10
E
Exterior Concrete Block - Int Insul UNIT 3
4.1 45
10
450.0 ftz
0
0
0.5
0
_ 11
S
Exterior Concrete Block - Int Insul UNIT 3
4.1 II16
10
160.0 ftz
0
0
0.5
0
12
W
Exterior Concrete Block - Int Insul UNIT 3
4.1 45
10
450.0 ftz
0
0
0.6
0
_ 13
N
Exterior Concrete Block - Int InsWNIT 4 AND
4.1 32
10
320.0 ftz
0
0
0.5
0
14
E
Exterior Concrete Block - Int lnsWNIT 4 AND
4.1 45
10
450.0 ftz
0
0
0.5
0
15
S
Exterior Concrete Block - Int InsWNIT 4 AND
4.1 32
10
320.0 ftz
0
0
0.5
0
18
W
Exterior Concrete Block - Int InsWNIT 4 AND
4.1 45
10
450.0 ftz
0
0
0.5
0
_ 17
N
Exterior Concrete Block - Int Insul UNIT 6
4.1 116
10
160.0 ftz
0
0.5
0
18
E
Exterior Concrete Block - Int Insul UNIT 6
4.1 45
10
450.0 ftz
0
0.5
0
_ 19
S
Exterior Concrete Block - Int Insul UNIT 6
4.1 16
10
160.0 ftz
0
0.5
0
_20
W
Exterior Concrete Block - Int Insul UNIT 6
4.1 46
10
450.0 ftz
0
0.5
0
I
I
101171201811:44 AM EnergyGauge® USA Section R405. I.1 Compliant Software Page 3 of 6
FORM R405-2017 INPIIT CI IMMA12V r14=f%Vl ICT DCDnDT
OORS
#
Omt Door Type Space
I
Storms
U Value
Width
Height
Area
Ft
In
Ft In
1
N Insulated UNIT 1
None
.37 3
6 8
20 ft2
2
N Insulated UNIT 2
None
.37 3
6 8
20 ft2
3
S Insulated UNIT 3
None
.37 3
6 8
20 ft2
4
W Insulated UNIT 4 AND
None
.37 3
6 8
20 ft2
5
W Insulated UNIT 4 AND
None
.37 3
6 8
20 ft2
6
S Insulated UNIT 6
None
.37 3
6 8
20 11t2
WINDOWS
Orientation shown Is the entered Proposed orientation.
/
Wall
Overhang
#
Omt ID Frame Panes NFRC
U-Factor SHGC
Imp
Area Depth
Separation
Int Shade
Screening
1
N 1 Metal Low-E Double Yes
0.65 0.25
N
40.0 ft2 1 It 0 in
1 ft 4 in
Drapes/blinds
None
2
S 3 Metal Low-E Double Yes
0.6 0.25
N
20.0 ft2 1 ft 0 in
1 ft 4 in
Drapes/blinds
None
3
W 4 Metal Low-E Double Yes
0.6 0.25
N
15.0 ft2 1 ft 0 in
1 ft 4 In
Drapes/blinds
None
4
N 5 Metal Low-E Double Yes
0.65 0.25
N
40.0 ft2 1 ft 0 in
1 ft 4 in
Drapes/blinds
None
5
S 7 Metal Low-E Double Yes
0.6 0.26
N
20.0 ft2 1 ft 0 in
1 ft 4 in
Drapes/blinds
None
6
N 9 Metal Low-E Double Yes
0.66 0.25
N
40.0 ft2 1 ft 0 in
1 ft 41n
Drapesiblinds
None
7
S 11 Metal Low-E Double Yes
0.6 0.25
N
20.0 ft2 1 It 0 In
1 ft 41n
Drapes/blinds
None
8
N 13 Metal Low-E Double Yes
0.65 I0.25
N
80.0 ft2 1 ft 0 in
1 ft 4 In
Drapes/blinds
None
9
S 15 Metal Low-E Double Yes
0.6 0:25
N
40.0 ft2 1 ft 0 in
1 ft 4 in
Drapes/blinds
None
10
N 17 Metal Low-E Double Yes
0.65
N
40.0 ft2 1 ft 0 In
1 ft 4 in
Drapes/blinds
None
11
E 18 Metal Low E Double Yes
I0I.25
0.6 0.25
N
16.0 ft2 1 It 0 in
1 ft 4 in
Drapes/blinds
None
12
S 19 Metal Low-E Double Yes
0.6 0.25
I
N
20.0 ft2 1 ft 0 in
1 ft 4 in
Drapes/blinds
None
INFILTRATION
# Scope
Method SLA
CFM 50 EI-A
EgLA ACH
ACH 50
1 Wholehouse Proposed ACH(50) .000445
4718 25�.01
487.11 .3446
7
HEATING S�STEM
#
System Type Subtype
Efficiency
Capacity
Block
Ducts
1
Electric Strip Heat/ None
I
CORI
17 kBtu/hr
1
sys#1
2
Electric Strip Heat/ None
I
COP:1
17 kBtu/hr
2
sys#2
3
Electric Strip Heat/ None
COP:1
17 kBtu/hr
3
sys#3
5
Electric Strip Heat! None
COP:1
17 kBtu/hr
5
sys#5
4 A
Electric Strip Heat/ None
COP:1
17 kBtu/hr
4
sys#4
4 B
Electric Strip Heat/ None
I
COP:1
17 kBtu/hr
4
sys#4
I
I
i
10/17/201811:44 AM EnergyGauge® USA Section R405.4111 Compliant Software Page 4 of 6
I
FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT
COOLING SYSTEM
#
System Type
Subtype
Efficiency Capacity
Air Flow SHR
Block
Ducts
1
Central Unit/
None
SEER: 16 18.8 kBtu/hr
564 cfm 0.8
1
sys#1
2
Central Unit/
None
SEER: 16 18.8 kBtu/hr
564 cfm 0.8
2
sys#2
3
Central Unit/
None
SEER: 16 18.8 kBtu/hr
564 cfm 0.8
3
sys#3
5
Central Unit/
None
SEER: 16 18.8 kBtu/hr
564 cfm 0.8
5
sys#5
4 A
Central Unit/
None
SEER: 16 18.8 kBtu/hr
564 cfm 0.8
4
sys#4
4 B
Central Unit/
None
SEER: 16 18.8 kBtu/hr
564 cfm 0.8
4
sys#4
HOT WATER SYSTEM
i
#
System Type
SubType
Location
EF Cap Use
SetPnt Conservation
1
Electric
None
UNIT 1
0.95 I 40 gal 130 gal 120 deg
None
SOLAR HOT WATER SYSTEM
FSEC
Collector Storage
Cart # Company Name
System Modi el # Collector Model'# Area Volume
FEF
None None
I
ft'
DUCTS
/
— Supply —
— Return — I Air
CFM 25 CFM25
HVAC #
V
#
Location R Value Area
Location
Area Leakage Type Handler
TOT OUT QN
RLF
Heat Cool
1
Attic
6 135 ftz
Attic
35 ftz Del fault Leakage UNIT 1
(Default) (Default)
1 1
2
Attic
6 135 ft'
Attic
35 ftz Default Leakage UNIT 1
(Default) (Default)
2 2
3
Attic
6 135 fN
Attic
35 ft2 Default Leakage UNIT 1
(Default) (Default)
3 3
4
Attic
6 260 ftz
Attic
65 ftz Del ault Leakage UNIT 1
(Default) (Default)
4 4
5
Attic
6 135 ftz
Attic
35 ft2 Default Leakage UNIT 1
(Default) (Default)
5 5
TEMPERATURES
Programable Thermostat: Y
Ceiling Fans:
Cooling
Heating
Venting
Jan Feb
Jan Feb
Jan
Mar
Mar
[ j r
L l
Ma Jun X Jul Au
May Jun Jul Aug
Se Oct
Sep OctW
Nov
Nov
Dec
Feb
Mar
lxl Apr
lx�
Dec
10/17/201811:44 AM EnergyGauge® USA Section R405.411 Compliant Software Page 5 of 6
i
FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT
Thermostat Schedule: HERS 2006 Reference
Hours
Schedule Type
1
2
3
4
5
6
7
8
9
10
11
12
Cooling (WD)
AM
78
78
78
78
78
78
78
78
80
80
80
80
PM-
80
80
78
78
78
78
78
78
78
78
78
78
Cooling (WEH)
AM
78
78
78
78
78
78
78
78
78
78
78
78
PM
78
78
78
78
78
78
78
78
78
78
78
78
Heating (WD)
AM
66
66
66
66
66
68
68
68
Be
68
68
68
PM
68
68
.68
68
68
68
68
68
68
68
66
66
Heating (WEH)
AM
66
66
66
66
66
68
68
68
68
68
68
68
PM
68
Be
68
68
68
68
68
68
68
68
66
66
MASS
i
Mass Type
Area
Thickness
Furniture Fraction
Space
Default(8 Ibs/sq.ft.
0 ft2
0 ft
0.3
UNIT 1
Default(8 Ibs/sq.ft.
0 ft2
0 ft
0.3
UNIT 2
Default(8 Ibs/sq.ft.
0 ft2
0 ft
0.3
UNIT 3
Default(8 Ibs/sq.ft.
0 ft2
O ft
0.3
UNIT 4 AND 5
Default 8 Ibs/s .ft.
0 ft2
O ft
0.3
UNIT 6
Name: Test Rater
Rating Compant: Test Rater
I
I
I
I
I
I
10/17/2018 11:44 AM EnergyGauge® USA Section R405.4.1` Compliant Software
i
Page 6 of 6
2017 - I 0 AIR BARRIER AND INSULATION INSPECTION COMPONENT CRITERIA
TAB I E 402.4.1.1
AIR BARRIER AND INSULATION` INSPECTION COMPONENT CRITERIA
Project Name: SEDONA DEVELOPMENT 3135-3145 Builder Name:
Street: 3135-3145 ILLUSION CIRCLE Permit Office: ST. LUCIE COUNTY
City, State, Zip: FT. PIERCE, FL, Permit Number.
x
Owner: Jurisdiction:
w
Design Location: FL, Fort Pierce
=
v
COMPONENT
AIR BARRIER CRITERIA
INSULATION INSTALLATION CRITERIA
General
A continuous air barrier shall be installed In the building envelope.
Air -permeable insulation shall
requirements
The exterior thermal envelope contains a continuous air barrier.
Breaks or joints in the air barrier shall be sealed.
not be used as a sealing material.
The air barrier in any dropped ceiling/soffit shall tie aligned with
Ceiling/attic
the Insulation and any gaps in the air barrier shall be sealed.
The Insulation in any dropped ceiling/soffit
be
Access openings, drop down stairs or knee wall doors to
shall aligned with the air barrier.
unconditioned attic spaces shall be sealed.
The junction of the foundation and sill plate shall b'e sealed.
Walls
Cavities within corners and headers of frame walls
The junction of the top plate and the top of exterior walls shall be
shall be Insulated by completely filling the cavity
sealed.
with a material having a thermal resistance of R-3
Knee walls shall be sealed.
per inch minimum.
Exterior thermal envelope insulation for framed
walls shall be installed in substantial contact and
continuous alignment with the air barrier.
Windows, skylights
The space between window/door jambs and framing, and
and doors
skylights and framing shall be sealed. I
Rim joists
Rim joists shall include the air barrier. I
Rim joists shall be insulated.
Floors
The air barrier shall be Installed at any exposed edge of
Floor framing cavity insulation shall be installed to
(including
above -garage
insulation.
maintain permanent contact with the underside of
and cantilevered
subfloor decking, or floor framing cavity insulation
floors)
shall be permitted to be in contact with the top side
of sheathing, or continuous Insulation Installed on
the underside of floor framing and extends from the
bottom to the top of all perimeter floor framing '
members.
Crawl space walls
Exposed earth in unvented crawl spaces shall be cove�ed with
Where provided instead of floor insulation, insulation
a Class I vapor retarder with overlapping joints taped.
shall be permanently attached to the crawispace
Shafts, penetrations
Duct shafts, utility penetrations, and flue shafts opening to
exterior or unconditioned space shall be sealed.
Batts in narrow cavities shall be cut to fit, or narrow
Narrow cavities
cavities shall be filled by insulation that on
installation readily conforms to the available cavity
spaces.
Garage separation
Air sealing shall be provided between the garage and conditioned spac
3s.
Recessed lighting
Recessed light fixtures Installed in the building thermal envelope
Recessed light fixtures installed in the building
shall be sealed to the drywall. I
thermal envelope shall be air tight and IC rated.
Plumbing and wiring
I
Batt insulation shall be cut neatly to fit around wiring
and plumbing in exterior walls, or insulation that on
I
installation readily conforms to available space shall
awfand behind Iliping and wiring-
Shower/tub
on exterior wall
The air barrier installed at exterior walls adjacent to showers and
Exterior walls adjacent to showers and tubs shall
tubs shall separate them from the showers and tubs.
be insulated.
Electrical/phone box or
The air barrier shall be installed behind electrical or communication
exterior walls
boxes or air -sealed boxes shall be installed.
HVAC register boots
HVAC register boots that penetrate building thermal envelope shall
be sealed to the sub -floor or drywall.
Concealed
When required to be sealed, concealed fire sprinklers shall only be
sprinklers
sealed in a manner that is recommended by the manufacturer.
Caulking or other adhesive sealants shall not be used to fill voids
I
of log walls shall be in acco d ith
a. In addition, inspection
r once w the provisions of ICC-400.
10/17/201811:44 AM EnergyGauge® USA FBC 6th Edition (2017) Compliant Software Page 1 of 1
I
2017 EPL DISPLAY CARD
ENERGY PERFORMANCEI LEVEL (EPL) DISPLAY CARD
ESTIMATED ENERGY PERFORMANCE INDEX* = 94
The lower the Energy Performance Index, the more efficient the home.
1. New home or, addition 1. New (From Plans)
12. Ducts, location & insulation level
I
a) Supply ducts R
6.0
2. Single-family or multiple -family 2. Multi -family
b) Return ducts R
6.0
3. No. of units (ifmultiple-family) 3. 1
c) AHU location Attic/Attic
4. Number of bedrooms 4. 12 I
13. Cooling system: Capacity
112.8
a) Split system SEER
5. Is this a worst case? (yes/no) 5. No
b) Single package SEER
c) Ground/water source SEER/COP
6. Conditioned floor area (sq. ft.) 6. 4044
d) Room unit/PTAC EER
e) Other
16.0
7. Windows, type and area
a) U-factor:(weighted average) 7a. 0.631
b) Solar Heat Gain Coefficient (SHGC) 7b. 0.250
14. Heating system: Capacity
102.0
c) Area 7c. 390.0
a) Split system heat pump HSPF
b) Single package heat pump HSPF
8. Skylights
c) Electric resistance COP
1.0
a) U-factor:(weighted average) 8a. NA
d) Gas furnace, natural gas AFUE
b) Solar Heat Gain Coefficient (SHGC) 8b. NA
e) Gas furnace, LPG AFUE
0 Other
9. Floor type, insulation level:
a) Slab -on -grade (R-value) 9a. 0.0
b) Wood, raised (R-value) 9b.
15. Water heating system
c) Concrete, raised (R-value) 9c.
a) Electric resistance EF
0.95
b) Gas fired, natural gas EF
10. Wall type and insulation:
c) Gas fired, LPG EF
A. Exterior:
d) Solar system with tank EF
1. Wood frame (insulation R-value) 10A1.
e) Dedicated heat pump with tank EF
2. Masonry (insulation R-value) 10A2. 4.1
f) Heat recovery unit HeatRec%
B. Adjacent:
g) Other
1. Wood frame (Insulation R-value) 1061.
2. Masonry (insulation R-value) 10132.
16. HVAC credits claimed (Performance Method)
11. Ceiling
g type and insulation level
a) Ceiling fans
Yes
a) Under attic 11a. 30.0
b) Cross ventilation
No
b) Single assembly 11b.
c) Whole house fan
No
c) Knee walls/skylight walls Ile.
d) Multizone cooling credit
d) Radiant barrier installed 1 ld. Yes
e) Multizone heating credit
f) Programmable thermostat
Yes
*Label required by Section R303.1.3 of the Florida Building Code, Energy Conservation, if not DEFAULT.
I certify that this home has compiled with the Florida Building Code, Energy Conservation, through the above energy
saving features which will be installed (or exceeded) 'n this home before final inspection. Otherwise, a new EPL
display card will be completed based o ' stalled a compliant feat i res.
r IBuilder Signature:
Date:
Address of New Home: 3135-3145 ILLUSION CIRCLE I
I
City/FL Zip: FT. PIERCE, FL
101171201811 A4:38 AM EnergyGauge® USA 6.0.02 - FlaRes2017 FBC 6th Edition (2017) Compliant Software
Page 1 of 1
Michelle Franklin, CFA— Saint Lucie
Property Appraiser —All rights reserved.
SitcAddress:
Parcel ID:
Account#:
Map ID:
Use Type:
Zoning:
City/County:
ownership
Darrell Cotherman
Mary Cotherman
1626 Bowleys Quarters Rd
Baltimore, MD 21220
Legal Description
PORT ST LUCIE-SECTION 13- BLK 775 LOT I (MAP 44/05N) (OR 3125-233)
Current values
Just/Market Value:
Assessed Value:
Exemptions:
Taxable Value:
Taxes for this parcel: SLC Tax Collector's Office 12
Download TRIM for this parcel: Download PDF 12
Total Areas
Finishcd/Undcr Air (SF):
Gross Area (SF):
Land Size (acres):
Land Size (SF):
5186,800
$158,561
SO
$158,561
Z1o8
2,678
0.23
10,000
Identification
1837 SW Burlington ST
3420-560-3629-000-9
61173
I 44105N
0100
RS-2
Port Saint Lucie
- ---- -- -- - -- --- - ---- - - --- -- -- --- --- ---- - - - --- ------------------ -- - - - -- -------------- — - --- This information is believed to be correct at this time but it is subject to change and is not warranted.
® Copyright 2018 Saint Lucie County Property Appraiser. All rights reserved.
® Ri ht,Suite® Universal 2018 Short Form Job:
wrightsoft Date: OCTOBER 17, 2018
UNIT #1 By:
QUICK CALCS, INC.
317 ST. LUCIE LN., FT. PIERCE, FL 34946 Phone: 772-466-6799 Fax 772-466-6796 Email: QUICKCALCS@AOL.COM
I
Project• •
For. SEDONADEVELOPMENT
3135-3145 ILLUSION CIRCL , FT. PIERCE, FL
Htg Clg
Outside db
(OF)
42 90
Outside RH
(%)
- 60
Outside wb
(OF)
- 78
Daily range
(OF)
- 15
Moisture dill.
(grAb)
- 61
Heating Equipment
Make
Model
Type
Efficiency
Heating Input
Heating Output
Humidifier
Leaving Air Temp
Actual Heating Fan
Elec strip
100 EFF
5.0 kW
17.1 MBtuh
2.5 gpd
137.2 OF
231 cfm
Equipment Location
System Type
Fan Motor Heat Type
Fan & Motor Combined Efficiency
Static PressureAcross Fan
Htg Clg
Inside db (OF)
70 75
Inside RH N
- 50
Inside wb (OF)
- 63
Design TD (OF)
28 15
Cooling Equipment
Make
Trane
Model 4TTR6018J/TEM4AOB18S
Type
SplitAC
COP / EER / SEER
16.0
Sensible Cooling
13.2
MBtuh
Latent Cooling
5.6
MBtuh
Total Cooling
18.8
MBtuh
55.0
OF
ILem4ngAirTemp
al Cooling Fan
627
cfin
UNIT #1
PEAKCV
PACKAGE
0 %
0 in H2O
NAME
Area
ft2
Heat
Loss
Sensible I
Gain
Latent
Gain
Htg
cfin
Clg
cfm
Time
BEDROOM 1
188
5270
640 j
818
87
282
Jul 1700 LDT
BATH
40
714
267
0
11
11
Jul 1700 LDT
KITCHEN LIVING
278
3390
2929
0
50
116
Jul 1700 LDT
BEDROOM 2
107
3059
4744I
817
51
196
Jul 1700 LDT
ENTRY
69
2219
565
0
32
23
Jul 1700 LDT
UNIT #1
682
14652
14906 I
1635 1
231
627
Jul 1700 LDT
wr7ghlsoft" Right-Sute®Universal 201818.0.16RSUD8101
EDONA DEVELOPMENT-3135-3145 ILLUSION CIRCLE.rup Calc=CLTD Front Door faces: SE
file. c°pv
2018-Oct 1714:59:01
Page 2
® Ri ht-Suite® Universal 2018 Short Form Job:
wrightsoft Date: OCTOBER 17, 2018
UNIT #2 By:
QUICK CALCS, INC.
317 ST. LUCIE LN., Fr. PIERCE, FL 34946 Phone: 772-466-6799 Fax: 772-466-6796 Email: QUICKCALCS@,AOL.COM
I
Project
For. SEDONADEVELOPMENT
3135-3145 ILLUSION CIRCLE, FT. PIERCE, FL
I -
Htg Clg
Outside db
(OF)
42 90
Outside RH
(%)
- 60
Outside wb
(OF)
- 78
Daily range
(OF)
- 15
Moisture dill.
(grAb)
- 61
Heating Equipment
Make
Model
Type
Efficiency
Heating Input
Heating Output
Humidifier
Leaving Air Temp
Actual Heating Fan
Elec strip
100 EFF
5.0 kW
17.1 MBtuh
2.5 gpd
173.5 OF
150 crm
Equipment Location
System Type
Fan Motor Heat Type
Fan & Motor Combined Efficiency
Static Pressure Across Fan
Htg Clg
Inside db (OF)
70 75
Inside RH N
- 50
Inside wb (OF)
- 63
Design TD (OF)
28 15
Cooling Equipment
Make
Trane
Model
4TTR6018J/TEM4AOB18
Type
SplitAC
COP / EER / SEER
16.0
Sensible Cooling
13.2
MBtuh
Latent Cooling
5.6
MBtuh
Total Cooling
18.8
MBtuh
LeavingAirTemp
55.0
OF
Actual Cooling Fan
627
cfm
UNIT #2
PEAKCV
PACKAGE
0
%
0
in H2O
NAME
Area
ft2
Heat
Loss
Sensible I
Gain
Latent
Gain
Htg
ch
Clg
ch
Time
BEDROOM #1
188
4785
638�
818
62
318
Jul 1700 LDT
KITCHEN/LIVING.
274
2160
1403
916
23
63
Jul 1700 LDT
BATH #1
40
315
190
134
3
9
Jul 1700 LDT
BEDROOM #2
11.1
2665
4563I
468
35
205
Jul 1700 LDT
ENTRY
54
2268
796
553
26
33
Jul 1700 LDT
UNIT #2
667
12193
13336 I
2889
1 150
627
Jul 1700 LDT
wrightsoft- I 2018-Oct 1714:59:01
Right Sate® Uriversal 2018 18.0.16 RSU08101 I Page 3
EDONA DEVELOPMENT-3135-3145 ILLUSION CIRCLE.rup Calc= CLTD Front Door faces: SE
wrightsofte Right,Suite® Universal 2018 Short Form Date: OCTOBER 17, sole
UNIT #3 By:
QUICK CALCS, INC.
317 ST. LUCIE LN., FT. PIERCE, FL 34946 Phone: 772-466-6799 Fax: 772-466-6796 Email: QUICKCALCS@AOL.COM
For: SEDONADEVELOPMENT
3135-3145 ILLUSION CIRCL , FT. PIERCE, FL
r1>:g L;Ig
Outside db
(OF)
42 90
Outside RH
(%)
- 60
Outside wb
(OF)
- 78
Daily range
(OF)
- 15
Moisture dill.
(gr/Ib)
- 61
Heating Equipment
Make
Model
Type
Efficiency
Heating Input
Heating Output
Humidifier
Leaving Air Temp
Actual Heating Fan
Elec strip
100 EFF
5.0 kW
17.1 MBtuh
2.5 gpd
173.5 OF
150 c im
Equipment Location
System Type
Fan Motor Heat Type
Fan & Motor Combined Efficiency
Static PressureAcross Fan
Htg Cig
Inside db (OF)
70 75
Inside RH N
- 50
Inside wb (OF)
- 63
Design TD (OF)
28 15
Cooling Equipment
Make
Trane
Model
4TTR6018J/TEM4AOB18
Type
SplitAC
COP / EER / SEER
16.0
Sensible Cooling
13.2
MBtuh
Latent Cooling
5.6
MBtuh
Total Cooling
18.8
MBtuh
LewAngAirTemp
55.0
OF
Actual Cooling Fan
627
cfm
UNIT #3
PEAKCV
PACKAGE
0
%
0
in H2O
NAME
Area
fi?
Heat
Loss
Sensible I
Gain
Latent
Gain
Htg
Cfm
Clg
Crm
Time
BEDROOM 1.
188
4720
6349
818
62
316
Jul 1700 LDT
BATH 1
40
312
189
134
3
9
Jul 1700 LDT
KITHCEN/LIVING.
278
2167
1415
929
24
63
Jul 1700 LDT
BEDROOM 2.
107
2607
4568
458
34
205
Jul 1700 LDT
ENT.
54
2240
801I
553
26
34
Jul 1700 LDT
UNIT #3
667
12046 1
13321 I
2892
1 150
627
Jul 1700 LDT
- wrightsoft-
��„,, M- Right-SUte®Universal201818.0.16RSU08101 I
EDONADEVELOPMEIVr3135-3145ILLUSION CIRCLE.rup Catc=CLTD Front Door faces: SE
II
i
2018-Oct-1714:59:01
Page 4
wrightsoft® Right -Suite® Universal 2018 Short Form Date: OCTOBER 17, sole
UNIT #4 Br.
QUICK CALCS, INC.
317 ST. LUCIE LN., Fr.. PIERCE, FL 34946 Phore: 772-466-6799 Fax: 772-466-6796 Email: QUICKCALCS@,AOL.COM
I
Project• •
For. SEDONADEVELOPMENT
3135-3145 ILLUSION CIRCL , FT. PIERCE, FL
I
Htg Clg
Outside db
(OF)
42 90
Outside RH
N
- 60
Outside wb
(OF)
- 78
Daily range
(OF)
- 15
Moisture dill.
(gr/lb)
- 61
Heating Equipment
Make
Model
Type
Efficiency
Heating Input
Heating Output
Humidifier
Leaving Air Temp
Actual Heating Fan
Elec strip
100 EFF
5.0 kW
17.1 MBtuh
2.5 gpd
173.5 OF
150 cfin
Equipment Location
System Type
Fan Motor Heat Type
Fan & Motor Combined Efficiency
Static PressureAcross Fan
Htg Clg
Inside db (OF)
70 75
Inside RH (0/0)
- 50
Inside wb (OF)
- 63
Design TD (OF)
28 15
Cooling Equipment
Make
Trane
Model
4TTR6018J/TEM4AOB18
Type
SplitAC
COP / EER / SEER
16.0
Sensible Cooling
13.2
MBtuh
Latent Cooling
5.6
MBtuh
Total Cooling
18.8
MBtuh
LeavingAirTemp
55.0
OF
Actual Cooling Fan
627
clim
UNIT #4
PEAKCV
PACKAGE
0
%
0
in H2O
NAME
Area
ftz
Heat
Loss
Sensible I
Gain
Latent
Gain
Htg
chn
Clg
cfm
Time
BEDROOM #1.
188
4275
571
818
62
293
Jul 1700 LDT
KIT/ LIV
274
1968
2390
916
23
107
Jul 1700 LDT
BATH #1.
40
287
176
134
3
8
Jul 1700 LDT
ENTRY..
54
2053
71 J
553
26
31
Jul 1700 LDT
BED. 2
111
2380
4083I
468
35
189
Jul 1700 LDT
UNIT #4
667
10963 1
13068I
2889 1
150
627
Jul 1700 LDT
I
wrightsoft'° I 2018-Oct 1714:59:01
Right Sdte®Uriversa12018 18.0.16 RSU08101 I Page 5
EDONADEVELOPMENT-3135-3145 ILLUSION CIRCLE.rup Calc=CLTD Frord Door toes: SE
wrightsoft® Right -Suite® Universal 2018 Short Form Job:DateOCTOBER 17, zols
UNIT #5 By:
QUICK CALCS, INC.
317 ST. LUCIE LN., FT. PIERCE, FL 34946 Phone: 772-466-6799 Fax: 772-466-6796 Email: QUICKCALCS@,40L.COM
For: SEDONADEVELOPMENT �
3135-3145 ILLUSION CIRCLE, FT. PIERCE, FL
Htg Clg
Outside db
(OF)
42 90
Outside RH
(%)
- 60
Outside wb
(OF)
- 78
Daily range
(OF)
- 15
Moisture dill.
(grAb)
- 61
Heating Equipment
Make
Model
Type
Efficiency
Heating Input
Heating Output
Humidifier
Leaving Air Temp
Actual Heating Fan
Elec strip
100 EFF
5.0 kW
17.1 MBtuh
2.5 gpd
94.8 OF
627 cfiT1
Equipment Location
System Type
Fan Motor Heat Type
Fan & Motor Combined Efficiency
Static PressureAcross Fan
Htg Clg
Inside db (OF)
70 75
Inside RH N
- 50
Inside wb (OF)
- 63
Design TD (OF)
28 15
Cooling Equipment
Make
Trane
Model
4TTR6018J/TEM4AOB18
Type
SplitAC
COP / EER / SEER
16.0
Sensible Cooling
13.2
MBtuh
Latent Cooling
5.6
MBtuh
Total Cooling
18.8
MBtuh
Lea%ingAirTemp
55.0
OF
Actual Cooling Fan
627
cfm
UNIT #5
PEAKCV
PACKAGE
0
%
0
in H2O
NAME
Area
ft2
Heat
Loss
Sensible I
Gain
Latent
Gain
Htg
dm
Clg
cfm
Time
K1TA-IV
278
1996
2425
929
100
108
Jul 1700 LDT
BED.1
188
4275
571�
818
259
291
Jul 1700 LDT
BTH 1
40
287
170
134
14
8
Jul 1700 LDT
BED. #2
107
2360
4109
458
144
189
Jul 1700 LDT
ENT..
54
2053
721I
553
109
31
Jul 1700 LDT
UNIT #5
667
10972 1
13137 I
2892
1 627
627
Jul 1700 LDT
- wrightsoft® I 2018-Oct 1714:59:01
.,.,,,,.,� �,,,..„.,� Right-Sute®Uriversal201818.0.16RSU08101 I Page
EDONADEVELOPMENT-3135-3145ILLUSION CIRCLE.rup Calc=CLTD Front Door faces: SE
wrightsoft® Right -Suite® Universal 2018 Short Form Date: OCTOBER 17, zols
AHU #6 By:
QUICK CALCS, INC.
317 ST. LUCIE LN., FT. PIERCE, FL 34946 Phone: 772466-6799 Fax 772466-6796 Email: QUICKCALCS@j40L.COM
For: SEDONADEVELOPMENT �
3135-3145 ILLUSION CIRCLE, FT. PIERCE, FL
Htg Clg
Htg Clg
Outside db
(OF)
42 90
Inside db
(OF)
70 75
Outside RH
(%)
- 60
Inside RH
M
- 50
Outside wb
(OF)
- 78
Inside wb
(OF)
- 63
Daily range
(OF)
- 15
Design TD
(OF)
28 15
Moisture dill.
(grAb)
- 61
Heating Equipment
Cooling Equipment
Make
Make
Trane
Model
Model
4TTR6018J/TEM4AOB18
Type
Elec strip
Type
SplitAC
Efficiency
100 EFF
COP / EER / SEER
16.0
Heating Input
5.0 kW
Sensible Cooling
13.2
MBtuh
Heating Output
17.1 MBtuh
Latent Cooling
5.6
MBtuh
Humidifier
2.5 gpd
Total Cooling
18.8
MBtuh
LeavingAirTemp
143.2 OF
LeavingAirTemp
55.0
OF
Actual Heating Fan
212 cIm
Actual Cooling Fan
627
dm
Equipment Location
AHU #6
System Type
PEAKCV
Fan Motor Heat Type
PACKAGE
Fan & Motor Combined Efficiency
0
%
Static PressureAcross Fan
0
in H2O
NAME
Area
ft2
Heat
Loss
Sensible I
Gain
Latent
Gain
Htg
cfm
Clg
chn
Time
BED #1
188
5262
6226
628
79
285
Jul 1700 LDT
BTH #1
40
713
396
134
10
17
Jul 1700 LDT
IQT/LIV.
274
3531
2284
916
48
97
Jul 1700 LDT
ENTRY 1
69
2216
854
591
29
36
Jul 1700 LDT
BED #2.
111
2934
4266I
278
45
192
Jul 1700 LDT
AHU #6
682
1 14656
1 14027I
2547
1 212
627
Jul 1700 LDT
I
I
I
I
I
I
I
I
I 2018-Oct-1714:59:01
� rN/BnbFm..b.gcmw^/
- wrightsoft ° Rigs SUte®UNversa12018 18.0.16 RSU08101 Page 1
EDONA DEVELOPMENT-3135-3145 ILLUSION CIRCLE.rup Calc=CLTD FrordDoor faoes:SE
" wrightsoft® Right -Suite® Universal 2018 Load Summary
UNIT #1
QUICK CALCS, INC.
317 ST. LUCIE LN., Fr.. PIERCE, FL 34946 Phone: 772-466-6799 Fax. 772-466-6796 Emai
For: SEDONADEVELOPMENT
3135-3145 ILLUSION CIR(
1. DESIGN CONDITIONS at Jul 1700 LDT
Inside: 75 OF Outside: 90 OF
RH: 60 % MoistDiff: 61.5 (
2. SOLAR RADIATION THROUGH GLASS
FT. PIERCE, FL
3.
TRANSMISSION GAINS
Sensible
Walls:
1957
Glass:
1285
Doors:
101
Partitions:
0
Floors:
0
Ceilings:
1306
4.
INTERNAL HEAT GAIN
Sensible
Occupants:
460
Lights:
0
Motors:
0
Appliances:
931
5.
INFILTRATION:
Outside air cfm:
6.
SUBTOTAL: Spaceload Sensible
Envelope
10673
Less external
0
Redistribution
0
7.
SUPPLY DUCT
8.
SUBTOTAL: Space load
+ supply duct
9.
Actual cfm:
VENTILATION:
627 at suppply TD:
Make-up air cfrn:
10.
RETURN AIR LOAD:
Lighting + plenum (I
11.
RETURN DUCT
12.
TOTAL LOADS ON EQUIPMENT
13. DESIGN CONDITIONS
Inside: 70 OF
Outside: 42 OF
14.
TRANSMISSION LOSSES
Walls:
3444
Glass:
2481
Doors:
194
Partitions:
0
Floors:
1378
Ceilings:
511
15.
INFILTRATION:
Outside air cfm:
16.
SUBTOTAL: Spaceload
Envelope
10980
Less external
0
Less transfer
0
Redistribution
0
17.
SUPPLY DUCT-
18.
VENTILATION:
Make-up air cfm:
19.
HUMIDIFICATION
Piping
20.
RETURN DUCT
Job:
Date: OCTOBER 17, 2018
By:
Peak load at Jul 1700 LDT
TD: 15 OF
Mult 1.0 Ins.wb 63 OF
Sensible Latent
4154 -
4648 -
Latent
1391
380
380
-
-
0
-
-
30
480
1255
Latent
10673
1635
1635
-
-
0
-
-
2515
-
13189
-
20
-
-
0
0
0
0
-
1717
-
14906
1635
Mult 1.0
TD: 28 OF
8008
I 97 2971
10980
2145
1 0 0
I 954
0
Al.574
TOTAL HEATING LOAD ON EQUIPMENT I 14652
Ad- i 2018-Oct 1714:59:01
+• - �.. Rigtt-SUte®Universa12018 18.0.16 RSU08101 Page t
EDONADEVELOPMENT-3135-3145ILLUSION CIRCLE.rup Calc=CLTD Front Door faces: SE I
® Right-Suite(g) Universal 2018 Load Summary Job:
wrightsoft UNIT #2 Date: OCTOBER 17, 2018
By:
QUICK CALCS, INC.
317 ST. LUCIE LN., Fr. PIERCE, FL 34946 Phone: 772-466-6799 Fax 772-466-6796 Ema
For: SEDONADEVELOPMENT I
3135-3145 ILLUSION CIRCLE, FT. PIERCE, FL
1.
DESIGN CONDITIONS at Jul 1700 LDT
Peak load at Jul 1700 LDT
Inside: 75 OF Outside: 90 °F
TD:
15 OF
RH: 60 % MoistDifF 61.5 rAb
Mult
1.0 Ins.wb
63 OF
Sensible
Latent
2.
SOLAR RADIATION THROUGH GLASS
3954
-
3.
TRANSMISSION GAINS Sensible
3513
-
Walls: 1016
-
-
Glass: 1120
-
-
Doors: 101
-
-
Partitions: 0
-
-
Floors: 0
-
-
Ceilings: 1277
-
-
4.
INTERNAL HEAT GAIN Sensible
Latent
527
380
Occupants: 460
380
-
-
Lights: 0
-
-
-
Motors: 0
-
-
-
Appliances: 67
0
-
-
5.
INFILTRATION: Outside aircfm:
60
960
2509
6.
SUBTOTAL: Space load Sensible
Latent
8954
2889
Envelope 8954
2889
-
-
Less external 0
-
-
-
Redistribution 0
0
-
-
7.
SUPPLY DUCT
2605
-
8.
SUBTOTAL: Space load + supply duct
11560
-
Actual cfm: 627 at supply TD:
20
-
-
9.
VENTILATION: Make-up aircfm:
0
0
0
10.
RETURN AIR LOAD: Lighting + plenum (net
0
-
11.
RETURN DUCT
1776
-
12.
TOTAL LOADS ON EQUIPMENT
13336
2889
HEATING LOAD
13.
DESIGN CONDITIONS
Mult
1.0
Inside: 70 OF Outside: 42 OF
TD:
28 OF
14.
TRANSMISSION LOSSES
4852
Walls: 1357
-
Glass: 2162
-
Doors: 194
-
Partitions: 0
-
Floors: 638
-
Ceilings: 500
-
15.
INFILTRATION: Outside aircfm:
95
2926
16.
SUBTOTAL: Space load
7778
Envelope 7778
I
-
Less external 0
-
Less transfer 0
I
-
Redistribution 0
17.
SUPPLY DUCT:
2751
18.
VENTILATION: Make-up air cfm:
I 0
0
19.
HUMIDIFICATION
933
Piping
0
20.
RETURN DUCT
731
21.
TOTAL HEATING LOAD ON EQUIPMENT
I
12193
I
-pp- wrightsoft- I 2018-Oct-1714:59:01
mow- Rigtt-SUte6 UNversa12018 18.0.16 RSU06101 I Page 3
EDONA DEVELOPMENT-3135-3145 ILLUSION CIRCLE.rup Calc=CLTD Front Door faces: SE
wrightsoft® Right -Suite® Universal 2018 Load Summary
UNIT #3
QUICK CALCS, INC.
317 ST. LUCIE LN.. FT. PIERCE. FL 34946 Phone: 772-466-6799 Fax: 772-466-6796
For: SEDONADEVELOPMENT I
3135-3145 ILLUSION CIRCLE, FT. PIERCE, FL
Job:
Date: OCTOBER 17, 2018
By:
1.
DESIGN CONDITIONS at Jul 1700 LDT �
Peak load at Jul 1700 LDT
Inside: 75 OF Outside: 90 °F�
TD:
15 OF
RH: 60 % MoistDiff. 61.5 gdlb
Mult
1.0 Ins.wb
63 OF
Sensible
Latent
2.
SOLAR RADIATION THROUGH GLASS
3954
-
3.
TRANSMISSION GAINS Sensible
3551
-
Walls: 1053
-
-
Glass: 1120
-
-
Doors: 101
-
-
Partitions: 0
-
-
Floors: 0
-
-
Ceilings: 1277
-
-
4.
INTERNAL HEAT GAIN Sensible
Latent
527
380
Occupants: 460
380
-
-
Lights: 0
-
-
-
Motors: 0
-
-
-
Appliances: 67
0
-
-
5.
INFILTRATION: Outside aircfm:
60
962
2512
6.
SUBTOTAL: Spaceload Sensible
Latent
8993
2892
Envelope 8993
2892
-
-
Less external 0
-
-
-
Redistribution 0
0
-
-
7.
SUPPLY DUCT
2574
-
8.
SUBTOTAL: Space load + supply duct
11567
-
Actual cfin: 627 at supply TD:
20
-
-
9.
VENTILATION: Make-up air dim:
0
0
0
10.
RETURNAIRLOAD: Lighting + plenum (nefi
0
-
11.
RETURN DUCT
1755
-
12.
TOTAL LOADS ON EQUIPMENT
13321
2892
HEATING LOAD
13.
DESIGN CONDITIONS
Mult
1.0
Inside: 70 OF Outside: 42 OF
TD:
28 OF
14.
TRANSMISSION LOSSES
4852
Walls: 1357
-
Glass: 2162
-
Doors: 194
-
Partitions: 0
-
Floors: 638
-
Ceilings: 500
I
15.
INFILTRATION: Outside aircfm:
I 95
2930
16.
SUBTOTAL: Spaceload
7782
Envelope 7782
I
-
Less external 0
-
Less transfer 0
-
Redistribution 0
-
17.
SUPPLY DUCT:
2629
18.
VENTILATION: Make-up air cFm:
I 0
0
19.
HUMIDIFICATION
I
937
Piping
I
0
20.
RETURN DUCT
698
21.
TOTAL HEATING LOAD ON EQUIPMENT
12046
wrightsoft- i 2018-Oct 1714:59:01
��_• _ RightSUWDUrrversa1201818.0.16RSU08101 Page
EDONA DEVELOPMENT-3135-3145 ILLUSION CIRCLE.rup Calc=CLTD Front Door faces: SE
® Right-Suite(g) Universal 2018 Load Summary Job:
wrightsoft UNIT Date: OCTOBER 17, 2018
By:
QUICK CALCS, INC.
317 ST. LUCIE LN., Fr.. PIERCE, FL 34946 Phore: 772-466-6799 Fax: 772-466-6796 Emil: QUICKCALCS@AOL.COM
For: SEDONADEVELOPMENT I
3135-3145 ILLUSION CIRCLE, FT. PIERCE, FL
1.
DESIGN CONDITIONS at Jul 1700 LDT I
Peak load at Jul 1700 LDT
Inside: 75 OF Outside: 90 �
TD:
15 OF
RH: 60 % MoistDiff: 61.5 gdlb
Mult
1.0 Ins.wb
63 OF
Sensible
Latent
2.
SOLAR RADIATION THROUGH GLASS
3954
-
3.
TRANSMISSION GAINS Sensible
3513
-
Walls: 1016
-
-
Glass: 1120
-
-
Doors: 101
-
-
Partitions: 0
-
-
Floors: 0
-
-
Ceilings: 1277
-
-
4.
INTERNALHEAT GAIN Sensible
Latent
1378
380
Occupants: 460
380
-
-
Lights: 0
-
-
-
Motors: 0
-
-
-
Appliances: 918
0
-
-
5.
INFILTRATION: Outside air cIrn:
60
960
2509
6.
SUBTOTAL: Space load Sensible
Latent
9805
2889
Envelope 9805
2889
-
-
Less external 0
-
-
-
Redistribution 0
0
-
-
7.
SUPPLY DUCT
1947
-
8.
SUBTOTAL: Space load + supply duct
11752
-
Actual cfm: 627 at supply TD:
20
-
-
9.
VENTILATION: Make-up air CFm:
0
0
0
10.
RETURN AIR LOAD: Lighting + plenum (net
0
-
11.
RETURN DUCT I
1316
_ 12.
TOTAL LOADS ON EQUIPMENT I
13068
2889
HEATING LOAD
13.
DESIGN CONDITIONS
Mult
1.0
Inside: 70 OF Outside: 42 OF
TD:
28 OF
14.
TRANSMISSION LOSSES
4852
Walls: 1357
-
Glass: 2162
-
Doors: 194
-
Partitions: 0
-
Floors: 638
-
Ceilings: 500
15.
INFILTRATION: Outside aircfm:
95
I
2926
16.
SUBTOTAL: Space load
7778
Envelope 7778
-
Less external 0
I
-
Less transfer 0
-
Redistribution 0
17.
SUPPLY DUCT
I
1786
18.
VENTILATION: Make-up air cIrn:
0
0
19.
HUMIDIFICATION
I
933
Piping
I
0
2.
RETURN DUCT
466
21.
TOTAL HEANG LOAD ON EQUIPMENT
�,
10963
wrightsofte
• ��-. ' Right-Sate®Urrversa1201818.0.16RSU08101
EDONADEVELOPMENT-3135-3145ILLUSION CIRCLE.rup Calc=CLTD Frord Door faces: SE
2018-Oct-1714:59:01
Page 5
wrightsoft® Right -Suite® Universal 2018 Load Summary
UNIT #5
QUICK CALCS, INC.
317 ST. LUCIE LN., FT. PIERCE, FL 34946 Phone: 772-466-6799 Fax 772-466-6796 Ems
For: SEDONADEVELOPMENT I
3135-3145 ILLUSION CIRCLE, FT. PIERCE, FL
Job:
Date: OCTOBER 17, 2018
By:
1.
DESIGN CONDITIONS at Jul 1700 LDT �
Peak load at Jul 1700 LDT
Inside: 75 OF Outside: 90 °F�
TD:
15 OF
RH: 60 % MoistDiif 61.5 gdlb
Mult
1.0 Ins.wb
63 OF
Sensible
Latent
2.
SOLAR RADIATION THROUGH GLASS
3954
-
3.
TRANSMISSION GAINS Sensible
3551
-
Walls: 1053
-
-
Glass: 1120
-
-
Doors: 101
-
-
Partitions: 0
-
-
Floors: 0
-
-
Ceilings: 1277
-
-
4.
INTERNAL HEAT GAIN Sensible
Latent
1391
380
Occupants: 460
380
-
-
Lights: 0
-
-
-
Motors: 0
-
-
-
Appliances: 931
0
-
-
5.
INFILTRATION: Outside air cf n:
60
962
2512
6.
SUBTOTAL: Spaceload Sensible
Latent
9857
2892
Envelope 9857
2892
-
-
Less external 0
-
-
-
Redistribution 0
0
-
-
7.
SUPPLY DUCT
1957
-
8.
SUBTOTAL: Space load + supply duct
11814
-
Actual cfm: 627 at supply TD:
20
-
-
9.
VENTILATION: Make-up aircfm:
0
0
0
10.
RETURNAIR LOAD: Lighting + plenum (nefi
0
-
ll.
RETURN DUCT
1323
-
12.
TOTAL LOADS ON EQUIPMENT
13137
2892
HEATING LOAD
13.
DESIGN CONDITIONS
Mult
1.0
Inside: 70 OF Outside: 42 OF
TD:
28 OF
14.
TRANSMISSION LOSSES
4852
Walls: 1357
-
Glass: 2162
-
Doors: 194
-
Partitions: 0
-
Floors: 638
-
Ceilings: 500
15.
INFILTRATION: Outside aircfm:
95
I
2930
16.
SUBTOTAL: Spaceload
7782
Envelope 7782
I
-
Less external 0
I
-
Less transfer 0
-
Redistribution 0
17.
SUPPLY DUCT-
I
1787
18.
VENTILATION: Make-up air cfm:
0
0
19.
HUMIDIFICATION
937
Piping
II
0
20.
RETURN DUCT
466
21.
TOTAL HEATING LOAD ON EQUIPMENT
10972
-Ok- wri�ghtsoft-
Rigtt-SUte@ Udversa12018 18.0.16 RSU08101
EDONA DEVELOPMENT-3135-3145 ILLUSION CIRCLE.rup Calc=CLTD Frord Door facm. SE
2018-Oct-1 7 14:59:01
Page 6
wrightsoft® Right-Suite®Universal 2018 Load Summary Date: OCTOBER 17, 2018
AHU #6 By.
QUICK CALCS, INC.
317 ST. LUCIE LN., FT. PIERCE, FL 34946 Phone: 772-466-6799 Fax. 772-466-6796 Email: QUICKCALCS(, 40L.COM
For: SEDONADEVELOPMENT I
3135-3145 ILLUSION CIRCLE, FT. PIERCE, FL
1.
DESIGN CONDITIONS at Jul 1700 LDT
Peak load at Jul 1700 LDT
Inside: 75 OF Outside: 90 °F I
TD:
15 OF
RH: 60 % MoistDiff 61.5 gdlb
Mult
1.0 Ins.wb
63 OF
Sensible
Latent
2.
SOLAR RADIATION THROUGH GLASS
4121
-
3.
TRANSMISSION GAINS Sensible
4954
-
Walls: 2262
-
-
Glass: 1285
-
-
Doors: 101
-
-
Partitions: 0
-
-
Floors: 0
-
-
Ceilings: 1306
-
-
4.
INTERNAL HEAT GAIN Sensible
Latent
0
0
Occupants: 0
0
-
-
Lights: 0
-
-
-
Motors: 0
-
-
-
Appliances: 0
0
-
-
5.
INFILTRATION: Outside air cfm:
61
975
2547
6.
SUBTOTAL: Spaceload Sensible
Latent
10049
2547
Envelope 10049
2547
-
-
Less external 0
-
-
-
Redistribution 0
0
-
-
7.
SUPPLY DUCT
2364
_
8.
SUBTOTAL: Space load + supply duct
12413
-
Actual cfm: 627 at sup ly TD:
20
9.
VENTILATION: Make-up air
0
0
0
10.
RETURN AIR LOAD: Lighting + plenum (nefi
0
-
11.
RETURN DUCT
1614
-
12.
TOTAL LOADS ON EQUIPMENT
14027
2547
�-
HEATING LOAD
�
13.
DESIGN CONDITIONS
Mult
1.0
Inside: 70 OF Outside: 42 OF
TD:
28 OF .
14.
TRANSMISSION LOSSES
8035
Walls: 3470
-
Glass: 2481
-
Doors: 194
-
Partitions: 0
-
Floors: 1378
-
Ceilings: 511
-
15.
INFILTRATION: Outside air cfm:
96
2968
16.
SUBTOTAL: Spaceload
11002
Envelope 11002
-
Less external 0
_
Less transfer 0
I
_
Redistribution 0
17.
SUPPLY DUCT:
2134
18.
VENTILATION: Make-up air cfm:
I 0
0
19.
HUMIDIFICATION
950
Piping
II
0
20.
RETURN DUCT
570
21.
TOTAL HEATING LOAD ON EQUIPMENT
14656
-Pk- wriightsoft-
- �a Right-SUte@Uriversa1201818.0.16RSU08101
EDONA DEVELOPMENT-3135-3145 ILLUSION CIRCLE.rup Calc=CLTD FrorrtDoor faoes:SE
2018-Oct-1714:59:01
Page 1
Y
wri htsofto Duct System Summary Job:
9 UNI% #7 DBate: OCTOBER 17, 2018
y.
QUICK CALCS, INC.
317 ST. LUCIE LN., FT. PIERCE, FL 34946 Phone:772-466-6799 Fax 772-466-6796 Emil: QUICKCALCS@�40L.COM
I
Project Information
For. SEDONADEVELOPMENT I
3135-3145 ILLUSION CIRCLE, FT. PIERCE, FL
EXtemal static pressure
Pressure losses
Available static pressure
Supply / return available pressure
Lowest friction rate
Actual airflow
Total effective length (TEL)
0
in H2O
in H2O
in H2O
0.000 / 0.000
in H2O
0
in/100ft
231
cfm
Cooling
0
in H2O
0
in H2O
0
in H2O
0.000 / 0.000
in H2O
0
in/100ft
627
cfm
Oft
Name
Design
(Btuh)
Htg
(cfm)
Clg
(cfm)
Design
FR
D'am
�(in)
H x W
(in)
Duct
Mat
Actual
Ln (ft)
Ftg.Egv
Ln (ft)
Trunk
BATH
h 242
11
11
0
0
Ox 0
ShMt
0
0
BEDROOM 1
c 3248
43
141
0
0
Ox 0
ShMt
0
0
BEDROOM 1-A
C 3248
43
141
0
0
Ox 0
ShMt
0
0
BEDROOM 2
c 2250
25
98
0
0
Ox 0
ShMt
0
0
BEDROOM2-A
c 2250
25
98
0
0
Ox0
ShMt
0
0
ENTRY
h 529
32
23
0
0
Ox 0
ShMt
0
0
KITCHEN LIVING
c 2657
50
116
0
0
OX 0
ShMt
0
0
Grille
Htg
Clg
TEL
Design
Meloc
Diam
H x W
Stud/Joist
Duct
Name
Size (in)
(cfm)
(cfm)
(ft)
FR
(fpm)
I (in)
(in)
Opening (in)
Mat
Trunk
rb3
Ox 0
231
627
0
0
0
I 0
Ox 0
ShMt
wrightsoft, �I 2018-Oct 1714:59:01
Rigtd-SUteSUriversal20l8l8.0.16RSU08101 Paget
EDONADEVELOPMENT-3135-3145ILLUSION CIRCLErup Calc=CLTD Frord Door faoes: SE
* wrightsofte
Duct System Sum
UNIT #2
QUICK CALCS, INC.
317 ST. LUCIE LN., FT. PIERCE, FL 34946 Phone: 772-466-6799 Fax: 772-466-6796
ry
QUICKCALCS@10L.COM
For: SEDONA DEVELOPMENT
3135-3145 ILLUSION CIRCLE, , T. PIERCE, FL
Job:
Date: OCTOBER 17, 2018
By:
Heating
Cooling
External static pressure
0
in H2O
0
in H2O
Pressure losses
q
in H2O
0
in H2O
Available static pressure
0
in H2O
0
in H2O
Supply / return available pressure
0.000 / 0.000
in H2O
0.000 / 0.000
in H2O
Lowest friction rate
0
in/100ft
0
in/100ft
Actual airflow
150
cfm
627
cfm
Total effective length (TEL)
0 ft
Name
Design
(Btuh)
Htg
(cfm)
Clg
(cfm)
Design
FR
Dliam
II(in)
H x W
(in)
Duct
Mati
Actual
Ln (ft)
Ftg.Egv
Ln (ft)
Trunk
BATH#1
c 177
3
9
0
0
Ox0
ShMt
0
0
BEDROOM#1
c 6587
62
318
0
0
Ox0
ShMt
0
0
BEDROOM#2
c 2122
17
102
0
0
Ox0
ShMt
0
0
BEDROOM#2-A
c 2122
17
102
0
0
OXO
ShMt
0
0
ENTRY,
c 690
26
33
0
0
Ox 0
ShMt
0
0
KITCHENILIVING.
c 1302
23
63
0
0
Ox 0
ShMt
0
0
Name
Grille
Size (in)
Htg
(cfm)
Clg
(dm)
TEL
(ft)
Design
FR
Meloc
(fpm)
Diam
(in)
H x W
(in)
Stud/Joist
Opening (in)
Duct
Mat
Trunk
rb4
Ox 0
150
627
0
0
0
0
Ox 0
ShMt
-*- wrightsoft® I 2018-Oct 1714:59:01
e�,.�• w,�.,�w� Right-SUte®Universal 201818.0.16RSUD8101 Page
EDONA DEVELOPMENT-3135-3145 ILLUSION CIRCLE.rup Calc=CLTD Front Door faces, SE
I
Duct Summary Job:
-�d- wrightsoft° Dt StSDate: OCTOBER 17, 2018
UNIT #3 By:
QUICK CALCS, INC.
317 ST. LUCIE LN., FT. PIERCE, FL 34946 Phone: 772466-6799 Fax 772466-6796 Email: QUICKCALCS@AOL.COM
I
Project• •
For. SEDONA DEVELOPMENT I
3135-3145 ILLUSION CIRCLE, T. PIERCE, FL
External static pressure
Pressure losses
Available static pressure
Supply / return available pressure
Lowestfrlction rate
Actual airflow
Total effeective length (TEL)
0
in H2O
0
in H2O
0
in H2O
0.000/0.000�
in H2O
0
in/100ft
150
cfm
Oft
Cooling
0
in H2O
0
in H2O
0
in H2O
0.000 / 0.000
in H2O
0
i n/100ft
627
clm
Name
Design
(Btuh)
Htg
(cfm)
Clg
(Cfm)
Design
FR
Diam
I(in)
H x W
(in)
Duct
Mat!
Actual
Ln (ft)
Ftg.Egv
Ln (ft)
Trunk
BATH 1
c 177
3
9
0
0
Ox 0
ShMt
0
0
BEDROOM 1.
C 6563
62
316
0
0
Ox 0
ShMt
0
0
BEDROOM 2.
C 2131
17
103
0
0
Ox 0
ShMt
0
0
BEDROOM 2.-A
c 2131
17
103
0
0
Ox 0
ShMt
0
0
ENT
c 696
26
34
0
0
Ox 0
ShMt
0
0
KITHCENILIVING.
C 1314
24
63
0
0
Ox 0
ShMt
0
0
Grille
Htg
Clg
TEL
Design
Meloc
Diam
H x W
Stud/Joist
Duct
Name
Size (in)
(cfm)
(cfm)
(ft)
FR
(fpm)
I (in)
(in)
Opening (in)
Mat
Trunk
rb5
Ox 0
150
627
0
0
0
I 0
Ox 0
ShMt
- wrightsoft, II 2018-Od-1714:59:01
Rigtt-Sute®Universal 201818.0.16RSU08101
i Page 4
EDONA DEVELOPMENT-3135-3145 ILLUSION CIRCLE.rup Calc=CLTD Front Door faces: SE
Duct System Summary Job.
- wrightsoft° Date: OCTOBER 17, 2018
UNIT #4 By:
QUICK CALCS, INC.
317 ST. LUCIE LN., FT. PIERCE, FL 34946 Phone: 772-466-6799 Fax 772-466-6796 Email: QUICKCALCS@,40L.COM
I
s Project Information
For: SEDONADEVELOPMENT �,T.
3135-3145 ILLUSION CIRCLE, PIERCE, FL
External static pressure
Pressure losses
Available static pressure
Supply / return available pressure
Lowest friction rate
Actual airflow
Total effective length (TEL)
0
in H2O
0
in H2O
0
in H2O
0.000 / 0.000
in H2O
0
in/100ft
150
cfm
Oft
Cooling
0
in H2O
0
in H2O
0
in H2O
0.000 / 0.000
in H2O
0
in/1 00ft
627
cfm
D'am
Design
Htg
Clg
Design
H x W
Duct
Actual
Ftg.Egv
Name
(Btuh)
(cfm)
(dim)
FR
�(in)
(in)
Matl
Ln (ft)
Ln (ft)
Trunk
BA11-I#1.
c 165
3
8
0
0
Ox0
ShMt
0
0
BED.2
C 3940
35
189
0
0
Ox 0
ShMt
0
0
BEDROOM#1.
C 6116
62
293
0
0
Ox0
ShMt
0
0
ENMY•
C 641
26
31
0
0
Ox 0
ShMt
0
0
KITJLIV
c 2228
23
107
0
0
Ox 0
ShMt
0
0
Grille
Htg
Clg
TEL
Design
Mreloc
Diam
H x W
Stud/Joist
Duct
Name
Size (in)
(cfm)
(cfm)
(ft)
FR
(fpm)
(in)
(in)
Opening (in)
Matl
Trunk
rb6
Ox 0
150
627
0
0
0
I 0
Ox 0
ShMt
wrightsoft® I 2018-Oct-1714:59:01
.�...• .�� w Rigtt-SL te®Urvversal2018 18.0.16 RSU08101 Page 5
EDONA DEVELOPMENT-3135-3145 ILLUSION CIRCLE.rup CaIc=CLTD Frord Door faces: SE
i
II
® Ductstem Summl
-�- wrightsoft System ry
UNIT #5 I
QUICK CALCS, INC.
I
317 ST. LUCIE LN., FT. PIERCE, FL 34946 Phone: 772-466-6799 Fax 772-466-6796 Ern pil: QUICKCALCS@AOL.COM
For. SEDONADEVELOPMENT
3135-3145 ILLUSION CIRCLE, FT. PIERCE, FL
External static pressure
Pressure losses
Available static pressure
Supply / return available pressure
Lowest friction rate
Actual airflow
Total effective length (TEL)
0.000 /
in H2O
in H2O
in H2O
in H2O
in/100ft
cfm
Oft
Job:
Date: OCTOBER 17, 2018
By:
Cooling
0
in H2O
0
in H2O
0
in H2O
0.000 / 0.000
in H2O
0
in/1 00ft
627
cfm
Design
Htg
Clg
Design
Diam
H x W
Duct
Actual
Ftg.Egv
Name
(Btuh)
(Cfm)
(cfm)
FR
I(in)
(in)
Matl
Ln (ft)
Ln (ft)
Trunk
BED.#2
c 3972
144
189
0
0
Ox0
ShMt
0
0
BED.1
c 6116
259
291
0
0
Ox 0
ShMt
0
0
BTH 1
h 165
14
8
0
0
Ox 0
ShMt
0
0
ENT..
h 648
109
31
0
0
Ox 0
ShMt
0
0
Krr/LIV
c 2261
100
108
0
0
Ox 0
ShMt
0
0
Grille
Htg
Clg
TEL
Design
Wloc
Diam
H x W
Stud/Joist
Duct
Name
Size (in)
(cfm)
(cfm)
(ft)
FR
(fpm)
(in)
(in)
Opening (in)
Mat
Trunk
rb1
Ox 0
627
627
0
0
0
L 0
Ox 0
ShMt
i
-01j- wrightsoft® i 2018-Oct-1714:59:01
o� ..•,� ,...�.,M.,�, , Right Sute®Universal 2018 18.0.16 RSU08101 Page 6
EDONA DEVELOPMENT-3135-3145 ILLUSION CIRCLE.rup CaIc=CLTD Front Door faces: SE
r
i
I
-�d- wrightsott° Duct System Summary
AHU #6 . I
QUICK CALCS, INC.
317 ST. LUCIE LN., FT. PIERCE, FL 34946 Phone:772-466-6799 Fax 772-466-6796 Erpail: QUICKCALCS@AOL.COM
For. SEDONADEVELOPMENT �
3135-3145 ILLUSION CIRCLE, FT. PIERCE, FL
Job:
Date: OCTOBER 17, 2018
By:
Heating
Cooling
External static pressure
0
in H2O
0
in H2O
Pressure losses
0
in H2O
0
in H2O
Available static pressure
0
in H2O
0
in H2O
Supply / return available pressure
0.000 / 0.000
in H2O
0.000 / 0.000
in H2O
Lowest friction rate
I 0
in/100ft
0
in/100ft
Actual airflow
2 2
cfm
627
cfm
Total effective length (TEL)
0 ft
Name
Design
(Btuh)
Htg
(cfm)
Clg
0m)
Design
FR
Diam
(in)
H x W
(in)
Duct
Mat
Actual
Ln (ft)
Ftg.Egv
Ln (ft)
Trunk
BED#1
c 3033
40
143
0
0
Ox 0
ShMt
0
0
BED#1-A
C 3033
40
143
0
0
Ox 0
ShMt
0
0
BED#2.
C 2047
22
96
0
0
Ox0
ShMt
0
0
BED#2: A
C 2047
22
96
0
0
Ox 0
ShMt
0
0
BTFI#1
C 360
10
17
0
0
Ox0
ShMt
0
0
ENMYI
C 756
29
36
0
0
Ox 0
ShMt
0
0
KIT/LIV.
C 2058
48
97
0
0
Ox 0
ShMt
0
0
Grille
Htg
Clg
TEL
Design
Vel is
Diam
H x W
Stud/Joist
Duct
Name
Size (in)
(cfm)
(cfm)
(ft)
FR
(fpm)
(in)
(in)
Opening (in)
Mat
Trunk
rb8
Ox 0
212
627
0
0
I
1 0
0
Ox 0
ShMt
wrightsoft. 2018-Oct-1714:59:01
.�,. •,m, ..w, .,�, Right Sute®Universal 2018 18.0.16 RSU08101 Page 1
EDONA DEVELOPMENT-3135-3145 ILLUSION CIRCLE.rup Calc=CLTD Front Door faces: SE
I
�I