Loading...
HomeMy WebLinkAboutBUILDING PERMIT APPLICATION 19-32i GENERAL NOTES OWNER & CONSULTANTS OWNER: SECTION 01000 GENERAL NOTES SURTERRA FLORIDA 01000-1 ALL ARCHITECTURAL, STRUCTURAL, ELECTRICAL, MECHANICAL, AND PLUMBING WORK SHALL BE N. 11TH ST. PERFORMED IN STRICT ACCORDANCE WITH ALL APPLICABLE NATIONAL AND LOCAL CODES AND ORDINANCES, TAM FLOOR SURTERRA WELLNESS ASD SKY WHETHER LISTED HEREIN OR NOT. TAMPA, FL 33602 CONTACT: NICHOLAS MONETTE 01000-2 ANY & ALL GOVERNING LOCAL LABOR LAWS, REGULATIONS & REQUIREMENTS AND THOSE SET AS BUILDING 404.920A890 EXT 507 REQUIREMENTS SHALL BE OBSERVED & FOLLOWED AS THEY RELATE TO THIS PROJECT. ARRANGEMENTS ARCHITECT: PRECLUDE ANY LABOR RELATED JOB DISPUTES COMPLIANCE WITH THESE REQUIREMENTS SHALL BE MADE BY GC TO & RELATED DELAYS/PROBLEMS & COSTS. ASO I SKY AVE 01000-3CONTRACTOR SHALL OBTAIN ALL REQUIRED BUILDING PERMITS AND CERTIFICATE OF OCCUPANCY PERMIT 1240E TAMPAFL , FL 336 AS WELL AS SEPARATE MECHANICAL, ELECTRICAL, AND PLUMBING PERMITS PRIOR TO AND DURING CONTACT: KEN KEN COWART 1240 East 5th Avenue CONSTRUCTION. 813.341.6804 Tampa, FL 33605 010004MATERIALS, DIMENSIONS, AND OTHER CONDITIONS NOT OTHERWISE INDICATED IN THESE DRAWINGS SHALL 7O6 1 1 U S HIGHWAY T 813.223.2293 BE INTERPRETED AS HAVING THE SAME MEANING AS THOSE MOST SIMILARLY DETAILED AND MORE FULLY DEFINED MEP/STRUCTURAL ENGINEER: ELSEWHERE IN THE DRAWINGS. WILSON &GIRGENTI, LLC PORT ST LUCIE F L 3�1' �/rJZ F 813.223.2433 01000-5THE EXTENT OF WORK SHALL BE LIMITED TO THAT INDICATED IN THE CONTRACT DOCUMENTS. NO P.O. BOX 1377 f WWW.asdsky.com ADDITIONAL WORK SHALL BE DONE WITHOUT WRITTEN APPROVAL OF OWNER. ANY ADDITIONAL WORK SAFETY HARBOR, FL 34695 PERFORMED WITHOUT PRIOR WRITTEN APPROVAL BY OWNER SHALL BE AT THE CONTRACTOR'S EXPENSE. 813.855.330 / CONTACT: JOSEPH GIRGENTI, P.E. 01000-6GC SHALL BE RESPONSIBLE FOR FIELD MEASURING OF EXISTING CONDITIONS PRIOR TO START OF WORK & DURING CONSTRUCTION AS NECESSARY TO ASSURE CONSTRUCTION ADHERENCE TO DRAWINGS. BY ENTERING i S U RAT E R R A CONDITIONS. INTO A CONSTRUCTION CONTRACT FOR THIS WORK, GC SHALL INDICATE HIS FAMILIARITY WITH THE SITE/FIELD FOR PERMIT & BIDDING ,\ WELLNESS 01000-7FLOOR TOLERANCE: IN LAYING OUT THE WORK TO BE COMPLETED, CONSIDERATION SHALL BE GIVEN TO VARIATIONS IN THE FLOOR LEVEL RESULTING FROM THE CONSTRUCTION QUALITY AND LIVE AND DEAD LOADS IMPOSED ON THE STRUCTURE. FIELD VERIFICATIONS SHALL BE MADE OF CONDITIONS TO VERIFY CONSTRUCTION TOLERANCES AND ALIGNMENT OF DOOR HEADS. OTHER HORIZONTAL ELEMENTS SHALL BE MAINTAINED AT CONSTANT LEVEL AND SHALL NOT FOLLOW VARIATIONS IN FLOOR PLANE. LEVEL FLOORS AS REQUIRED BY USING AN APPROVED LEVELING COMPOUND. 01000-8THE CONTRACTOR SHALL BE RESPONSIBLE FOR TAKING ADEQUATE PRECAUTIONS TO PROTECT BUILDING OCCUPANTS, MATERIALS, & EXISTING FINISHES THROUGHOUT ALL PHASES OF CONSTRUCTION. NOISE, SECURITY, AND DUST BARRIERS BETWEEN CONSTRUCTION AREAS AND OCCUPIED AND PUBLIC AREAS SHALL BE MAINTAINED BY CONTRACTOR. ARCHITECTURAL SYMBOLS KEY PLAN S H E ET_I ND EX 01000-9THE CONTRACTOR SHALL BE RESPONSIBLE FOR MAINTAINING BUILDING CORRIDORS CLEAR OF PROJECT MATERIALS AND EQUIPMENT. iew Name Q 2 01000-10 GC SHALL PROVIDE GENERAL CARPENTRY AS REQUIRED FOR WORK WHICH MAY NOT FALL UNDER THE 1 JURISDICTION OF A SPECIFIED TRADE BUT IS REQUIRED FOR PROPER JOB EXECUTION AND COMPLETION OF A1.01 'M "' "' ELEVATION INDICATOR: CONSTRUCTION. ELEV. NUMBER/ SHEET NUMBER 01000-11 NO MODIFICATIONS/REVISIONS/CHANGES SHALL BE UNDERTAKEN UNLESS SPECIFICALLY SO INSTRUCTED & APPROVED BY OWNER. SIM SECTION INDICATOR: 1 DRAWING NUMBER 01000-12 CONTRACTOR IS RESPONSIBLE FOR CHECKING ALL CONTRACT DOCUMENTS, FIELD CONDITIONS AND A101 SHEET NUMBER DIMENSIONS FOR ACCURACY AND CONFIRMING THAT WORK IS BUILDABLE AS SHOWN BEFORE PROCEEDING WITH CONSTRUCTION. IF THERE ARE ANY QUESTIONS, THE CONTRACTOR IS RESPONSIBLE FOR OBTAINING A CLARIFICATION FROM THE ARCHITECT BEFORE PROCEEDING WITH WORK IN QUESTION. i SIM ENLARGED PLAN/DETAIL: 01000-13 THE INTENT OF THE CONTRACT DOCUMENTS IS TO EXCLUDE ALL MATERIALS WHICH CONTAIN KNOWN 1 DRAWING NUMBER HAZARDOUS SUBSTANCES. THESE INCLUDE MATERIALS CONTAINING ASBESTOS, POLYCHLORINATED A701 SHEET NUMBER ' BIPHENYL(PCB), OR ANY OTHER KNOWN SUBSTANCES DETERMINED TO BE A HEALTH HAZARD BY THE UNITED STATES ENVIRONMENTAL PROTECTION AGENCY (EPA) AND OTHER RECOGNIZED AGENCIES. IN STUDYING THE CONTRACT DOCUMENTS, AND AT ANY TIME DURING EXECUTION OF THE WORK, THE CONTRACTOR SHALL AT ONCE ELEVATION HEIGHT INDICATOR: REPORT TO THE ARCHITECT ANY MATERIALS CONTAINING HAZARDOUS SUBSTANCES THAT HE/SHE MAY DISCOVER. 0'-0" A.F.F. HEIGHT T DO NOT PROCEED WITH INSTALLATION OF HAZARDOUS MATERIALS. 71F B.O. CEILING DESCRIPTION 01000-14 CONTRACTOR SHALL VERIFY PRESENCE OF HAZARDOUS MATERIALS WITH OWNER. ARCHITECT AND ITS CONSULTANTS SHALL HAVE NO RESPONSIBILITY FOR THE DISCOVERY, PRESENCE, HANDLING, REMOVAL, OR ALIGN DISPOSAL OF OR EXPOSURE OF PERSONS TO HAZARDOUS MATERIALS IN ANY FORM AT THE PROJECT SITE, ALIGN ELEMENTS INCLUDING BUT NOT LIMITED TO, ASBESTOS, POLYCHLORINATED BIPHENYL (PCB) OR OTHER TOXIC SUBSTANCES. 01000-15 WHERE PRODUCTS ARE SPECIFIED BY REFERENCE STANDARD OR IN DESCRIPTIVE MANNER WITHOUT Room name MANUFACTURER'S NAME, MODEL NUMBER OR TRADE NAME, CONTRACTOR SHALL SELECT MATERIALS MEETING 101 ROOM TAG SPECIFIED REQUIREMENTS WHICH DO NOT CONTAIN KNOWN HAZARDOUS SUBSTANCES IN ANY FORM AND SUBMIT TO ARCHITECT FOR APPROVAL. 01000-16 INSTALL ALL MANUFACTURED ITEMS, MATERIALS AND EQUIPMENT IN STRICT ACCORDANCE WITH THE A1.01 ALTERNATE NOTE MANUFACTURER'S RECOMMENDED SPECIFICATIONS, EXCEPT THAT THE SPECIFICATIONS HEREIN, WHERE MORE STRINGENT, SHALL BE COMPLIED WITH. zh REVISION NUMBER 1 01000-17 IN MAKING REQUESTS FOR SUBSTITUTION, CONTRACTOR SHALL BE RESPONSIBLE FOR DETERMINING � THAT MATERIALS REQUESTED FOR SUBSTITUTION ARE FREE OF KNOWN HAZARDOUS SUBSTANCES IN ANY FORM. l ' 1 CODED NOTE 01000-18 WARRANTY SHALL BE EXTENDED FOR ALL CONSTRUCTION COMPONENTS, EQUIPMENT AND MILLWORK NOTE 0 6 INSTALLATIONS INCLUDED IN THIS CONTRACT FOR A MINIMUM OF 1 YEAR FROM THE DATE OF SUBSTANTIAL ` 1 J 0 COMPLETION. 101 DOOR +ROOM NUMBER SHEET NO. SHEET TITLE ISSUE DATE REV NO. REVISIO DATE REV NO. REVISION DATE A0.00 INDEX AND PROJECT INFORMATION 05-23-18 1 07-31-18 2 08-28-18 AO.1 LIFE SAFETY PLAN 05-23-18 1 07-31-18 2 08-28-18 AO.11 SPECIFICATIONS_ 05-23-18 AO.12 SPECIFICATIONS 05-23-18 05-23-18 AO.13 SPECIFICATIONS AO.14 SPECIFICATIONS 05-23-18 AO.15 SPECIFICATIONS 05-23-18 A1.01 CONSTRUCTION PLAN & DEMOLITION PLAN 05-23-18 05-23-18 1 07-31-18 A2.01 REFLECTED CEILING PLAN & POWER & COMMUNICATIONS PLAN A3.01 SECURITY PLAN 05-23-18 1 0741-18 A3.02 FURNITURE & FINISH PLAN 05-23-18 A6.01 INTERIOR ELEVATIONS & ENLARGED PLANS 65-23-18 A6.02 INTERIOR ELEVATIONS & ENLARGED PLANS 05-23-18 A6.03 INTERIOR ELEVATIONS & ENLARGED PLANS 05-23-18 1 07-31-18 A6.04 INTERIOR ELEVATIONS & ENLARGED PLANS 05-23-18 A6.05 PRODUCT DISPLAY 05-23-18 05-23-18 05-23-18 1 07-31-18 A6.06 PRODUCT DISPLAY A7.01 PARTITION TYPES & DETAILS A7.02 DETAILS 05-23-181 07-31-18 T 08-28-18 A7.04 PRODUCT APPROVALS A7.05 PRODUCT APPROVALS 08-28-18 08-28-18 A7.06 PRODUCT APPROVALS A7.07 PRODUCT APPROVALS 08-28-18 E1.0 LIGHTING PLAN 05-23-18 E3.0 ELECTRICAL PLAN 05-23-18 M1.0 IMECHANICAL PLAN 05-23-18 P1.0 PLUMBING PLAN OS-23-18 P2.0 _ PLUMBING SCHEDULES AND DETAILS 05-23-18 •U J a-+ (n N LO a 3a LL1 c N 0 CCi U C J (� CO t:: o a. 01000-19 GC SHALL RE -EXECUTE ANY WORK THAT FAILS TO CONFORM TO THE DRAWINGS/DETAILS AS SHOWN ^+ DOOR TYPE I HARDWARE SET AND ANY DEFECTS DUE TO FAULTY MATERIALS OR WORKMANSHIP WHICH APPEAR WITHIN A PERIOD OF ONE (1) $T. I LJCILI CON pjj Lv FIRS; MARSHALS OFFICE fo YEAR. T.+ EQUIPMENT NOTE 01000-20 SHOP DRAWINGS SHALL BE SUBMITTED TO ARCHITECT IN TRIPLICATE FOR REVIEW. SHOP DRAWINGS REVIEWED AND A13PROV �J ENHANCE THESE SPECIFICATIONS: APPROVAL OF SHOP DRAWINGS SHALL NOT RELEASE CONTRACTOR FROM WALL TYPE TAG REVIEWED BY: � RESPONSIBILITY FOR THE WORK AS SPECIFIED. DATE: 01000-21 THESE DOCUMENTS INDICATE MATERIALS AND METHODS OF CONSTRUCTION TO ESTABLISH 1E WINDOW TYPE TAG STANDARDS OF QUALITY AND/ OR PERFORMANCE. OTHER MATERIALS AND/OR METHODS WILL BE CONSIDERED BY Florida Business License #: AA26001572 THE ARCHITECT FOR ACCEPTANCE PROVIDED THAT THEY DO NOT AFFECT THE VISIBLE APPEARANCE. MATERIAL S _ • LUCIE COUNTY Registered Architect: Kenneth Cowart SUBSTITUTIONS SHALL BE APPROVED BY THE ARCHITECT IN WRITING PRIOR TO ORDERING AND/OR FABRICATION. ABBREVIATIONS LOCATION MAP FLAN REVIEW Registered Architect License #: AR93215 01000-22 ALL REQUESTS FOR SUBSTITUTIONS SHALL BE SUBMITTED IN WRITING TO THE ARCHITECT AND WILL BE This drawing is the property of Associated CONSIDERED ONLY IF BETTER SERVICE FACILITIES, A MORE ADVANTAGEOUS DELIVERY DATE, OR LOWER PRICE Space Design, Inc. and is not to be reproduced or copied in whole or WITH CREDIT TO THE OWNER IS PROVIDED WITHOUT SACRIFICING QUALITY, APPEARANCE AND FUNCTION. UNDER ti L0G: part It is NO CIRCUMSTANCES WILL THE ARCHITECT BE REQUIRED TO PROVE THAT A PRODUCT PROPOSED FOR A/C AIR CONDITIONER LAB LABORATORY not to be used on any other project and is to ADJ ADJACENT LAM LAMINATED DATE: 9 / be returned upon request. Scales as stated SUBSTITUTION IS OR IS NOT OF EQUAL QUALITY TO THE PRODUCT SPECIFIED. ADMIN ADMINISTRATION LAV LAVATORY >SCANNW AFF ABOVE FINISH FLOOR MAX MAXIMUM E LE G - herein are for reference only as normal a ' reproduction processes may alter the 01000-23 CONTRACTOR SHALL SUBMIT TO THE ARCHITECT, IMMEDIATELY FOLLOWING DIRECTIVE TO PROCEED ALT ALTERNATE MECH MECHANICAL DATE. WITH WORK, CONFIRMATION WITH DELIVERY DATES FOR ORDERS OF MATERIALS AND EQUIPMENT AND ANY LONG ALUM ALUMINUM MEZZ MEZZANINE �t 11*I�r�Ij116� PLUMB' !!p� accuracy of original drawings. _ Associated Space Design, Inc.2018 LEAD TIME ITEMS. APPROX APPROXIMATE MFR MANUFACTURER Scented Dragcrr DATE; O ' D / 01000-24 DAMAGE: CONTRACTOR SHALL BE RESPONSIBLE FOR THE REPAIRS OF ANY ACCIDENTAL DAMAGE ARCH ARCHITECTURAL MMANAGER AVG AVERAGE MISMISCELLANEOUS I MECH: HE/SHE INFLICTS UPON THE EXISTING WORK WHICH WILL REMAIN. IF FOR ANY REASON DAMAGE TO EXISTING BLDG BUILDING MIN MINIMUM WORK OR UTILITIES IS CONSIDERED TO BE UNAVOIDABLE, SUBMIT WRITTEN NOTIFICATION OF THIS BEFORE BOT BOTTOM NIC NOT IN CONTRACT a'' tAke vist�s'a'V 1zkeV eia SIGNING THE CONTRACT. IN THE ABSENCE OF SUCH NOTIFICATION, CONTRACTOR ASSUMES FULL RESPONSIBILITY CPT CARPET NTS NOT TO SCALE FOR DAMAGE AND THE COSTS OF SATISFACTORILY REPAIRING OR REPLACING DAMAGED WORK. CAB CABINET NOM NOMINAL CL CENTERLINE OC ON CENTER 1j°° " a «01 01000-25 FINAL CLEANING AT COMPLETION SHALL INCLUDE DUSTING OF ALL FINISHED SURFACES, VACUUMING, CLG CEILING OPNG OPENING REMOVAL OF SPOTS, STAINS, LABELS, FINGERPRINTS, SPILLS, AND CLEANING OF ALL INTERIOR GLASS. CLGHT CEILING HEIGHT OPP OPPOSITE .' 17061 U.S. 1 d CONCFAMAS i ENERS OR ATTACHMENTS CLR CLEAR PL PLASTIC LAMINATE 01000-26 NOT USED CONF CONFERENCE PLAM PLASTIC LAMINATE u CONT CONTINUOUS PLYWD PLYWOOD REJIQIiS191lITY0FTHE 01000-27 JOB SITE CLEAN-UP SPECIFIED IN 01000-14 SHALL CONTINUE BEYOND DATE OF SUBSTANTIAL CORR CORRIDOR PT PAINT Bayshore Club _ �JiTI�A or R��QR� COMPLETION TO MOVE -IN DAY AND SHALL INCLUDE REMOVAL OF ACCUMULATED DEBRIS RESULTING FROM WORK DIA DIAMETER QTY QUANTITY India Spicy' v. BY TELECOMMUNICATIONS CONTRACTORS AND OTHER VENDORS UNDER CONTRACT TO THE OWNER. (NOTE: St Lucie Oaks Apartments DIM DIMENSION REF REFRIGERATOR BingaMadness9 p FURNITURE PACKING MATERIALS WILL BE RESPONSIBILITY OF FURNITURE VENDOR.) ON DOWN REFRIG REFRIGERATOR > DR DOOR REQ REQUIRED THESE PLANS AND ALL PROPOSED Uw :, 01000-28 FIRE RATED PARTITIONS SHALL BE NOTED IN STENCIL ABOVE FINISHED CEILING PER APPLICABLE CODE. DTL/DET DETAIL REV REVISION/REVISED ARtetiCaflFreight Ai1E UcUZCT TO ANY CORRECTIONS"" ORRECTIONS DWG DRAWING RM ROOM Furnitura a...Maiuess V 01000-29 GENERAL CONDITIONS (ALA DOCUMENT A201) APPLIES TO THIS PROJECT AND IS APART OF THIS EL ELEVATION SAN SANITARY m R aJUIhEII FiY MI LD IN6PECTORSTUT �,;Y Jc rJECcaaARY1M ORDER TO 2 08-28-18 PERMIT COMMENTS CONTRACT. ELEV ELEVATOR 5CHED. SCHEDULE - m t� ES3 2 EQ EQUAL SEC SECRETARY r, °� F t 1 07-31-18 PERMIT COMMENTS 01000-30 VERIFY SPECIFIC SECURITY REQUIREMENTS WITH TENANT. EQUIP EQUIPMENT SF SQUARE FOOT Z A Beautiful Day Florist OOMPLY �IITH %�iAPP L CODS, potlar General t� EXST EXISTING SIM SIMILAR � N0. DATE REMARKS 01000-31 SPRINKLER HEAD LOCATIONS SHALL BE COORDINATED WITH OTHER TRADES BY GC AND SHALL BE AS FE FINISHED END SPECS SPECIFICATIONS ntreasure Coast Magic .y SPECIFIED BY ENGINEER OR AS REQUIRED BY CODE. SPRINKLERS SHALL BE CENTERED WITHIN EACH CEILING TILE FE FIRE EXTINGUISHER SQ SQUARE 3eda Rome Bakey REVISIONS TO PROVIDE A UNIFIED, CONSISTENT AND AESTHETIC ARRANGEMENT. HEADS SHALL BE WHITE FLUSH TYPE OR FEC FIRE EXTINGUISHER CABINET SS STAINLESS STEEL 1q DRAWING TITLE: BUILDING STANDARD IF EQUAL OR BETTER. FL FLOOR STD STANDARD Baach Ave FURN FURNITURE STOR STORAGE e ANUM Pine FILE COPY, INDEX AND PROJECT GA GAUGE SW SWITCH >` p Lakes Apartments INFORMATION GALV GALVANIZE TV TELEVISION � � "an � PROJECT DESCRIPTION GWB GYPSUM WALL BOARD TYP TYPICAL v. n,:u: aoe ,?y hq Apex Pr GYP BD GYPSUM BOARD UNO UNLESS NOTED OTHERWISE - � PROJECT NO.: ISSUE DATE: HDW HARDWARE VCT VINYL COMPOSITION TILE RWE"D 51394.64 05-23-18 HVAC HEATING,VENTILATING,AIR VERT VERTICAL INTERIOR RENOVATION OF AN EXISTING RETAIL SPACE FOR A RETAIL FACILITY IN WHICH STATE LICENSED CANNABIS CONDITIONING VWC VINYL WiALLCOVERING SEP 041018 DRAWN BY: CHECKED BY: RELATED PRODUCTS ARE SOLD. IN ADDITION TO RETAIL SPACE AND ELEMENTS, THE RENOVATION WILL INCLUDE AN INT INTERIOR VEST VESTIBULE AC KN ADA COMPLIANT RESTROOM, AND BACK OF HOUSE SPACE ACCESSIBLE TO EMPLOYEES ONLY. JAN JANITOR W/ WITH �nrmitgiap oaparcmant JUNC JUNCTION WC WALLCOVERING 9F, 4400 County SHEET NUMBER: WD WOOD Cft6 s W/O WITHOU'i- A0 ■ OO I GENERAL NOTES SECTION 01000 GENERAL NOTES 01000-1 ALL ARCHITECTURAL, STRUCTURAL, ELECTRICAL, MECHANICAL, AND PLUMBING WORK SHALL BE PERFORMED IN STRICT ACCORDANCE WITH ALL APPLICABLE NATIONAL AND LOCAL CODES AND ORDINANCES, WHETHER LISTED HEREIN OR NOT. 01000-2ANY & ALL GOVERNING LOCAL LABOR LAWS, REGULATIONS & REQUIREMENTS AND THOSE SET AS BUILDING REQUIREMENTS SHALL BE OBSERVED & FOLLOWED AS THEY RELATE TO THIS PROJECT. ARRANGEMENTS PRECLUDE ANY LABOR RELATED JOB DISPUTES COMPLIANCE WITH THESE REQUIREMENTS SHALL BE MADE BY GC TO & RELATED DELAYS/PROBLEMS & COSTS. 01000-3CONTRACTOR SHALL OBTAIN ALL REQUIRED BUILDING PERMITS AND CERTIFICATE OF OCCUPANCY PERMIT AS WELL AS SEPARATE MECHANICAL, ELECTRICAL, AND PLUMBING PERMITS PRIOR TO AND DURING CONSTRUCTION. 01000-4MATERIALS, DIMENSIONS, AND OTHER CONDITIONS NOT OTHERWISE INDICATED IN THESE DRAWINGS SHALL BE INTERPRETED AS HAVING THE SAME MEANING AS THOSE MOST SIMILARLY DETAILED AND MORE FULLY DEFINED ELSEWHERE IN THE DRAWINGS. 01000-5THE EXTENT OF WORK SHALL BE LIMITED TO THAT INDICATED IN THE CONTRACT DOCUMENTS, NO ADDITIONAL WORK SHALL BE DONE WITHOUT WRITTEN APPROVAL OF OWNER. ANY ADDITIONAL WORK PERFORMED WITHOUT PRIOR WRITTEN APPROVAL BY OWNER SHALL BE AT THE CONTRACTOR'S EXPENSE. 01000-6 GC SHALL BE RESPONSIBLE FOR FIELD MEASURING OF EXISTING CONDITIONS PRIOR TO START OF WORK & DURING CONSTRUCTION AS NECESSARY TO ASSURE CONSTRUCTION ADHERENCE TO DRAWINGS. BY ENTERING INTO A CONSTRUCTION CONTRACT FOR THIS WORK, GC SHALL INDICATE HIS FAMILIARITY WITH THE SITE/FIELD CONDITIONS, 01000-7 FLOOR TOLERANCE: IN LAYING OUT THE WORK TO BE COMPLETED, CONSIDERATION SHALL BE GIVEN TO VARIATIONS IN THE FLOOR LEVEL RESULTING FROM THE CONSTRUCTION QUALITY AND LIVE AND DEAD LOADS IMPOSED ON THE STRUCTURE. FIELD VERIFICATIONS SHALL BE MADE OF CONDITIONS TO VERIFY CONSTRUCTION TOLERANCES AND ALIGNMENT OF DOOR HEADS. OTHER HORIZONTAL ELEMENTS SHALL BE MAINTAINED AT CONSTANT LEVEL AND SHALL NOT FOLLOW VARIATIONS IN FLOOR PLANE. LEVEL FLOORS AS REQUIRED BY USING AN APPROVED LEVELING COMPOUND. 01000-8THE CONTRACTOR SHALL BE RESPONSIBLE FOR TAKING ADEQUATE PRECAUTIONS TO PROTECT BUILDING OCCUPANTS, MATERIALS, & EXISTING FINISHES THROUGHOUT ALL PHASES OF CONSTRUCTION. NOISE, SECURITY, AND DUST BARRIERS BETWEEN CONSTRUCTION AREAS AND OCCUPIED AND PUBLIC AREAS SHALL BE MAINTAINED BY CONTRACTOR. 01000-9THE CONTRACTOR SHALL BE RESPONSIBLE FOR MAINTAINING BUILDING CORRIDORS CLEAR OF PROJECT MATERIALS AND EQUIPMENT. 01000-10 GC SHALL PROVIDE GENERAL CARPENTRY AS REQUIRED FOR WORK WHICH MAY NOT FALL UNDER THE JURISDICTION OF A SPECIFIED TRADE BUT IS REQUIRED FOR PROPER JOB EXECUTION AND COMPLETION OF CONSTRUCTION. 01000-11 NO MODIFICATIONS/REVISIONS/CHANGES SHALL BE UNDERTAKEN UNLESS SPECIFICALLY SO INSTRUCTED & APPROVED BY OWNER. 01000-12 CONTRACTOR IS RESPONSIBLE FOR CHECKING ALL CONTRACT DOCUMENTS, FIELD CONDITIONS AND DIMENSIONS FOR ACCURACY AND CONFIRMING THAT WORK IS BUILDABLE AS SHOWN BEFORE PROCEEDING WITH CONSTRUCTION. IF THERE ARE ANY QUESTIONS, THE CONTRACTOR IS RESPONSIBLE FOR OBTAINING A CLARIFICATION FROM THE ARCHITECT BEFORE PROCEEDING WITH WORK IN QUESTION. 01000-13 THE INTENT OF THE CONTRACT DOCUMENTS IS TO EXCLUDE ALL MATERIALS WHICH CONTAIN KNOWN HAZARDOUS SUBSTANCES. THESE INCLUDE MATERIALS CONTAINING ASBESTOS, POLYCHLORINATED BIPHENYL(PCB), OR ANY OTHER KNOWN SUBSTANCES DETERMINED TO BE A HEALTH HAZARD BY THE UNITED STATES ENVIRONMENTAL PROTECTION AGENCY (EPA) AND OTHER RECOGNIZED AGENCIES, IN STUDYING THE CONTRACT DOCUMENTS, AND AT ANY TIME DURING EXECUTION OF THE WORK, THE CONTRACTOR SHALL AT ONCE REPORT TO THE ARCHITECT ANY MATERIALS CONTAINING HAZARDOUS SUBSTANCES THAT HE/SHE MAY DISCOVER DO NOT PROCEED WITH INSTALLATION OF HAZARDOUS MATERIALS. 01000-14 CONTRACTOR SHALL VERIFY PRESENCE OF HAZARDOUS MATERIALS WITH OWNER. ARCHITECT AND ITS CONSULTANTS SHALL HAVE NO RESPONSIBILITY FOR THE DISCOVERY, PRESENCE, HANDLING, REMOVAL, OR DISPOSAL OF OR EXPOSURE OF PERSONS TO HAZARDOUS MATERIALS IN ANY FORM AT THE PROJECT SITE, INCLUDING BUT NOT LIMITED TO, ASBESTOS, POLYCHLORINATED BIPHENYL (PCB) OR OTHER TOXIC SUBSTANCES. 01000-15 WHERE PRODUCTS ARE SPECIFIED BY REFERENCE STANDARD OR IN DESCRIPTIVE MANNER WITHOUT MANUFACTURER'S NAME, MODEL NUMBER OR TRADE NAME, CONTRACTOR SHALL SELECT MATERIALS MEETING SPECIFIED REQUIREMENTS WHICH DO NOT CONTAIN KNOWN HAZARDOUS SUBSTANCES IN ANY FORM AND SUBMIT TO ARCHITECT FOR APPROVAL. 01000-16 INSTALL ALL MANUFACTURED ITEMS, MATERIALS AND EQUIPMENT IN STRICT ACCORDANCE WITH THE MANUFACTURER'S RECOMMENDED SPECIFICATIONS, EXCEPT THAT THE SPECIFICATIONS HEREIN, WHERE MORE STRINGENT, SHALL BE COMPLIED WITH. 01000-17 IN MAKING REQUESTS FOR SUBSTITUTION, CONTRACTOR SHALL BE RESPONSIBLE FOR DETERMINING THAT MATERIALS REQUESTED FOR SUBSTITUTION ARE FREE OF KNOWN HAZARDOUS SUBSTANCES IN ANY FORM. 01000-18 WARRANTY SHALL BE EXTENDED FOR ALL CONSTRUCTION COMPONENTS, EQUIPMENT AND INSTALLATIONS INCLUDED IN THIS CONTRACT FOR A MINIMUM OF 1 YEAR FROM THE DATE OF SUBSTANTIAL COMPLETION. 01000-19 GC SHALL RE -EXECUTE ANY WORK THAT FAILS TO CONFORM TO THE DRAWINGS/DETAILS AS SHOWN AND ANY DEFECTS DUE TO FAULTY MATERIALS OR WORKMANSHIP WHICH APPEAR WITHIN A PERIOD OF ONE (1) YEAR. 01000-20 SHOP DRAWINGS SHALL BE SUBMITTED TO ARCHITECT IN TRIPLICATE FOR REVIEW, SHOP DRAWINGS ENHANCE THESE SPECIFICATIONS: APPROVAL OF SHOP DRAWINGS SHALL NOT RELEASE CONTRACTOR FROM RESPONSIBILITY FOR THE WORK AS SPECIFIED. 01000-21 THESE DOCUMENTS INDICATE MATERIALS AND METHODS OF CONSTRUCTION TO ESTABLISH STANDARDS OF QUALITY AND/ OR PERFORMANCE. OTHER MATERIALS AND/OR METHODS WILL BE CONSIDERED BY THE ARCHITECT FOR ACCEPTANCE PROVIDED THAT THEY DO NOT AFFECT THE VISIBLE APPEARANCE. MATERIAL SUBSTITUTIONS SHALL BE APPROVED BY THE ARCHITECT IN WRITING PRIOR TO ORDERING AND/OR FABRICATION. 01000-22 ALL REQUESTS FOR SUBSTITUTIONS SHALL BE SUBMITTED IN WRITING TO THE ARCHITECT AND WILL BE CONSIDERED ONLY IF BETTER SERVICE FACILITIES, A MORE ADVANTAGEOUS DELIVERY DATE, OR LOWER PRICE WITH CREDIT TO THE OWNER IS PROVIDED WITHOUT SACRIFICING QUALITY, APPEARANCE AND FUNCTION. UNDER NO CIRCUMSTANCES WILL THE ARCHITECT BE REQUIRED TO PROVE THAT A PRODUCT PROPOSED FOR SUBSTITUTION IS OR IS NOT OF EQUAL QUALITY TO THE PRODUCT SPECIFIED. 01000-23 CONTRACTOR SHALL SUBMIT TO THE ARCHITECT, IMMEDIATELY FOLLOWING DIRECTIVE TO PROCEED WITH WORK, CONFIRMATION WITH DELIVERY DATES FOR ORDERS OF MATERIALS AND EQUIPMENT AND ANY LONG LEAD TIME ITEMS, 01000-24 DAMAGE: CONTRACTOR SHALL BE RESPONSIBLE FOR THE REPAIRS OF ANY ACCIDENTAL DAMAGE HE/SHE INFLICTS UPON THE EXISTING WORK WHICH WILL REMAIN. IF FOR ANY REASON DAMAGE TO EXISTING WORK OR UTILITIES IS CONSIDERED TO BE UNAVOIDABLE, SUBMIT WRITTEN NOTIFICATION OF THIS BEFORE SIGNING THE CONTRACT. IN THE ABSENCE OF SUCH NOTIFICATION, CONTRACTOR ASSUMES FULL RESPONSIBILITY FOR DAMAGE AND THE COSTS OF SATISFACTORILY REPAIRING OR REPLACING DAMAGED WORK. 01000-25 FINAL CLEANING AT COMPLETION SHALL INCLUDE DUSTING OF ALL FINISHED SURFACES, VACUUMING, REMOVAL OF SPOTS, STAINS, LABELS, FINGERPRINTS, SPILLS, AND CLEANING OF ALL INTERIOR GLASS. 01000-26 NOT USED 01000-27 JOB SITE CLEAN-UP SPECIFIED IN 01000-14 SHALL CONTINUE BEYOND DATE OF SUBSTANTIAL COMPLETION TO MOVE -IN DAY AND SHALL INCLUDE REMOVAL OF ACCUMULATED DEBRIS RESULTING FROM WORK BY TELECOMMUNICATIONS CONTRACTORS AND OTHER VENDORS UNDER CONTRACT TO THE OWNER. (NOTE: FURNITURE PACKING MATERIALS WILL BE RESPONSIBILITY OF FURNITURE VENDOR.) 01000-28 FIRE RATED PARTITIONS SHALL BE NOTED IN STENCIL ABOVE FINISHED CEILING PER APPLICABLE CODE. 01000-29 GENERAL CONDITIONS (AA DOCUMENT A201) APPLIES TO THIS PROJECT AND IS APART OF THIS CONTRACT, 01000-30 VERIFY SPECIFIC SECURITY REQUIREMENTS WITH TENANT. I01000-31 SPRINKLER HEAD LOCATIONS SHALL BE COORDINATED WITH OTHER TRADES BY GC AND SHALL BE AS SPECIFIED BY ENGINEER OR AS REQUIRED BY CODE. SPRINKLERS SHALL BE CENTERED WITHIN EACH CEILING TILE TO PROVIDE A UNIFIED, CONSISTENT AND AESTHETIC ARRANGEMENT. HEADS SHALL BE WHITE FLUSH TYPE OR BUILDING STANDARD IF EQUAL OR BETTER, PROJECT DESCRIPTION INTERIOR RENOVATION OF AN EXISTING RETAIL SPACE FOR A RETAIL FACILITY IN WHICH STATE LICENSED CANNABIS RELATED PRODUCTS ARE SOLD. IN ADDITION TO RETAIL SPACE AND ELEMENTS, THE RENOVATION WILL INCLUDE AN ADA COMPLIANT RESTROOM, AND BACK OF HOUSE SPACE ACCESSIBLE'TO EMPLOYEES ONLY. OWNER & CONSULTANTS OWNER: SURTERRA FLORIDA N. 11TH ST. 2ND FLOOR TAMPA, FL 33602 CONTACT: NICHOLAS MONETTE 404.920.4890 EXT 507 ARCHITECT: ASOISKY 1240 E 5TH AVE TAMPA, FL 33607 CONTACT: KEN COWART 813.341.6804 MEP/STRUCTURAL ENGINEER: WILSON & GIRGENTI, LLC P.O. BOX 1377 SAFETY HARBOR, FL 34695 813.855.330 / CONTACT: JOSEPH GIRGENTI, P.E. ARCHITECTURAL SYMBOLS ew Name 1 A1.01 121APh SIM 1 A101 SIM 1 A101 0'-0" A.F.F. B.O. CEILING ALIGN Room name 101 A1.01 Al /0 �J 101 it Af FT.1 O ELEVATION INDICATOR: ELEV. NUMBER{ SHEET NUMBER SECTION INDICTOR: DRAWING NUM ER SHEET NUMBE ENLARGED Pl. DRAWING NUI SHEET NUMB[ ELEVATION HE HEIGHT DESCRIPTION /_111111cm ROOM TAG ALTERNATE NC REVISION NUM CODED NOTE MILLWORK NO" DOOR + ROOM DOOR TYPE Tf EQUIPMENT NC WALL TYPE TA( WINDOW TYPE ABBREVIATIONS A/C AIR CONDITIONER ADJ ADJACENT ADMIN ADMINISTRATION AFF ABOVE FINISH FLOOR ALT ALTERNATE ALUM ALUMINUM APPROX APPROXIMATE ARCH ARCHITECTURAL AVG AVERAGE BLDG BUILDING BOT BOTTOM CPT CARPET CAB CABINET CL CENTERLINE CLG CEILING CLGHT CEILING HEIGHT CLR CLEAR CONF CONFERENCE CONT CONTINUOUS CORR CORRIDOR DIA DIAMETER DIM DIMENSION DN DOWN DR DOOR DTUDET DETAIL DWG DRAWING EL ELEVATION ELEV ELEVATOR EQ EQUAL EQUIP EQUIPMENT EXST EXISTING FE FINISHED END FE FIRE EXTINGUISHER FEC FIRE EXTINGUISHER CABINET FL FLOOR FURN FURNITURE GA GAUGE GALV GALVANIZE GWB GYPSUM WALLBOARD GYP BD GYPSUM BOARD HDW HARDWARE HVAC HEATING,VENTILATING,AIR CONDITIONING INT INTERIOR JAN JANITOR JUNC JUNCTION INDICATOR: SET 46 LABORATORY NM LAMINATED kV LAVATORY AX MAXIMUM ECH MECHANICAL EZZ MEZZANINE FIR MANUFACTURER GR MANAGER ISC MISCELLANEOUS IN MINIMUM IC NOT IN CONTRACT TS NOT TO SCALE OM NOMINAL C ON CENTER PNG OPENING PP OPPOSITE L PLASTIC LAMINATE LAM PLASTIC LAMINATE LYWD PLYWOOD T PAINT TY QUANTITY EF REFRIGERATOR EFRIG REFRIGERATOR EQ REQUIRED EV REVISION/REVISED M ROOM 4N SANITARY 1HED. SCHEDULE =C SECRETARY - SQUARE FOOT M SIMILAR DECS SPECIFICATIONS D SQUARE 3 STAINLESS STEEL rD STANDARD rOR STORAGE N SWITCH TELEVISION fP TYPICAL NO UNLESS NOTED OTHERWISE DT VINYL COMPOSITION TILE =RT VERTICAL NC VINYL WALLCOVERING 7-ST VESTIBULE / WITH C WALLCOVERING 'D WOOD 10 WITHOUT Min: I I %Imiii Is 7061 US HIGHWAY 1 PORT ST LUCIE, FL 34952 KEY PLAN SHEET INDEX LOCATION MAP Scented Dragon Bayshpre Club St L u_i, Oaks Apartments Endr Spice Bingr ,9.r[9r rss e.' 1_\ Arnerican Freight .;, Ft.-nitureard NiasEreps .. ijr,$ _ Dollar General B&la Rerti^s 'd dr}' Beach Ave q A Bpiutiftyl Day Florist Treasure Coast Magic ARIVM Fine. Lakes Apartmeri:_ Apex P, SHEET NO. SHEET TITLE ISSUE DATE REVISION NO. REVISION DATE AO.00 INDEX AND PROJECT INFORMATION 05-23-18 1 07-31-18 AO.1 LIFE SAFETY PLAN 05-23-18 1 07-31-18 AO.11 SPECIFICATIONS SPECIFICATIONS 05-23-18 AOA2 05-23-18 05-23-18 AO.13 SPECIFICATIONS AO.14 SPECIFICATIONS 05-23-18 AO.15 SPECIFICATIONS 05-23-18 A1.01 CONSTRUCTION PLAN & DEMOLITION PLAN 05-23-18 1 07-31-18 IQN 05-23-18 A3.01 SECURITY PLAN 05-23-18 1 07-31-18 05-23-18 A6.01 INTERIOR ELEVATIONS & ENLARGED PLANS 05-23-18 A6.02 INTERIOR ELEVATIONS & ENLARGED PLANS 05-23-18 A6.03 INTERIOR ELEVATIONS & ENLARGED PLANS 05-23-18 1 07-31-18 A6.04 INTERIOR ELEVATIONS & ENLARGAPLANSO.5-18 A6.05 PRODUCT DISPLAY-18 A6.06 PRODUCT DISPLAY-18 1 07-31-18 A7.01 PARTITION TYPES & DETAILS-18 A7.02 DETAILS-18 1 07-31-18 A7.03 DETAILS-18E1.0 LIGHTING PLAN-18E3.0 ELECTRICAL PLAN-18M1.0 MECHANICAL PLAN18 P1.0 PLUMBING PLAN 05-23-18 P2.0 PLUMBING SCHEDULES AND DETAILS 05-23-18 KRIJ l y AUG 17 2018 Perrnitting j'epalK St Lucie co, Jn 1240 East 5th Avenue Tampa, FL 33605 T 813.223.2293 F 813.223.2433 www.asdsky.com �U J U) (n N LO NN e- d. M L L w I Cz t U L W J Cn 1 U) �/� vJ � o 0_ M l` Florida Business License #: AA26001572 Registered Architect: Kenneth Cowart Registered Architect License #: AR93215 This drawing is the property of Associated Space Design, Inc. and is not to be reproduced or copied in whole or part. It is not to be used on any other project and is to be returned upon request. Scales as stated herein are for reference only as normal reproduction processes may alter the accuracy of original drawings. Associated Space Design, Inc. 2018 1 07-31-18 1 PERMIT OMMENTS DATE LARKS REVISIONS KING TITL IND ( AND PROJECT IN O;RMATION LRAW 513 4.64 05-23-18 N BY9 EC ED BY: AC KN .00 SYMBOL DESCRIPTION OCCUPANCY BUSINESS SQ FT 788 OCCUPANTS 8 OCCUPANCY MERCANTILE SQ FT 2,325 OCCUPANTS 39 P.O.S. L110J LI MECH o 109 L J 1' - D„ 4 -- — — J EXIT CORRIDOR 2 2 10 L 108 EC 9 ALCOVE 180 L 106 J O aOFFICE L1o7J RESTROOM r—� L 105 J 8 NEW HOLLOW 160 METAL DOOR EXIT PACK & FILL SECUR L112J L113J CI BOH 0111 / 1'_0" SECURE PANTRY — — — — — — — L 114 J TECH CIL — — 015 J FL — 05 I7 - T 71- I7 �I DAP RETAIL RETAIL _ _ GARDEN — — + — L 103 J IL I 102 J �L _ J _ 56' II _ II II _ II / CHECK -IN / LIVING RM CONSULTING L104J / L100J L101 J_L] U O EXIT / O O - -_- ------____-_-__-__-_ 1 LIFE SAFETY PLAN OCCUPANCY CLASSIFICATION NFPA 6.1.1 & NFPA 7.3.1.2 JURISDICTION: CITY OF PORT ST. LUCIE, FLORIDA A. CLASSIFICATION TYPE: MERCANTILE, GROUP M APPLICABLE CODES B. CONSTRUCTION AREA: 3113 SQ. FT. C. TENANT'S OCCUPANT LOAD: 52 BUILDING CODE: FLORIDA BUILDING CODE 2017 (6TH Edition) FLORIDA BUILDING CODE EXISTING 2017 (6TH Edition) ACCESSIBILITY CODE: FLORIDA ACCESSIBILITY CODE 2017 (6TH Edition) EGRESS WIDTH PER EXIT( INIMUM) NFPA TABLE 7.3.3.1 1. LEVEL .2 (32" DIVIDED BY .2 = 160 PERSONS @ EA. EXITS) LIFE SAFETY: NFPA 101 LIFE SAFETY CODE 2015 MECHANICAL CODE: FLORIDA MECHANICAL CODE 2017 (6TH Edition) 2. STAIRS .3 (44" DIVIDED BY .3 = 147 PERSONS @ EA. EXITS) PLUMBING CODE: FLORIDA PLUMBING CODE 2017 (6TH Edition) ELECTRICAL CODE: NFPA 70 NATIONAL ELECTRIC CODE 2014 MEANS OF EGRESS REQUIREMENTS FIRE: FLORIDA FIRE PREVENTION CODE (6TH Edition) FUEL GAS: FLORIDA FUEL & GAS CODE (6TH Edition) SPRINKLERED UNSPRINKLERED ENERGY CONSERVATION: FLORIDA ENERGY CONSERVATION (6TH Edition) A. MAXIMUM TRAVEL DISTANCE TO EXIT 300' 200' B. MAXIMUM DEAD END CORRIDOR 50' 20' C. COMMON PATH OF TRAVEL 100, 75' BUILDING DATA D. EXIT SEPARATION 1/3 OF DIAGONAL 1/2 OF DIAGONAL E. MINIMUM CORRIDOR WIDTH 44" 44" LOCATION 7061 US HIGHWAY 1, PORT ST. LUCIE, FL 34952 F. MINIMUM OPENING OF EXIT DOORS 2 2 G. MINIMUM RAMP/STAIRS WIDTH 44" 44" CONSTRUCTION TYPE TYPE VB SPRINKLERED NO INTERIOR FINISH REQUIREMENTS NUMBER OF FLOORS 1 A. FINISH REQS. / OCCUPANCY: FBC TABLE 803.5 (UNSPRINKLERED) B. EXITS: CLASS -A, FLAME SPREAD 01-26; SMOKE DEVELOPED 0-450 C. EXIT ACCESS: CLASS-B, FLAME SPREAD 26-75; SMOKE DEVELOPED 0-450 D. OTHER SPACES: CLASS-C, FLAME SPREAD 76-200; SMOKEDEVELOPED 0-450 FIRE PROTECTION REQUIREMENTS A. MANUAL FIRE ALARM BOXES: MIN. 5 FT. FROM EACH B. FIRE EXTINGUISHER REQUIREMENTS PER: EXIT C. MAXIMUM AREA PER EXTINGUISHER: NFPA 10 (1-6) D. MAXIMUM TRAVEL DISTANCE TO EXTINGUISHER: 11,250 SQ. FT. 75 FT. ACCESSIBILITY REQUIREMENTS A. A MINIMUM 60" x 60" LANDING FOR DIRECTION CHANGE AT TOP OF RAMP. B. A MINIMUM 18" UNOBSTRUCTED MANEUVERING CLEARANCE ON PULL SIDE DF DOOR(S). C. A MINIMUM 12" UNOBSTRUCTED MANEUVERING CLEARANCE ON PUSH SIDE OF DOOR(S) IF DOOR HAS BOTH A CLOSER AND LATCH. D. RESTROOM ACCESS AND CLEARANCES PER APPLICABLE PROVISIONS OFF C CH. 6, 604 (WATER CLOSETS), 605 (URINALS), 606 (LAVATORIES) E. ACCESSIBLE COUNTER SURFACE NO MORE THAN 34" A.F.F. F. A MINIMUM 36" LONG REAR GRAB BAR. G. A MINIMUM 42" LONG SIDE GRAB BAR. H. LEVER HARDWARE ON NEW OR RE -HUNG DOORS. I. NO KEY LOCKS ON EGRESS SIDE OF DOOR, 3 I BUILDING DATA & CODE REFERENCE SCOPE OF WORK RENOVATION LEVEL PER FBC FLOOR AREA SCOPE OF WORK SCOPE OF WORK OCCUPANCY 0 11 3,113 3,113 TYPE SQFT RATIO OCC. PER CODE ACTUAL OCC BUSINESS 788 1/100 8 8 ASSEMBLY 1 /15 STORAGE 1/200 MERCANTILE 2,325 1/60 39 39 TOTAL SCOPE OF WORK OCCUPANCY 47 47 TOTAL FLOOR OCCUPANCY N/A TOTAL OCCUPANCY ALLOWED BASED ON EGRESS WIDTH 640 EGRESS A� REQUIRED PROPOSED # OF EXITS 2 3 TOTAL EGRESS WIDTH 32" 128" COMMON PATH OF TRAVEL 75'4" 25'-0" OVERALL MAXIMUM DISTANCE OF TRAVEL 200'-0" 50'-0" SEPARATION OF EXITS 42'-10" 48'-1 1/2" PLUMBING FIXTURES PLUMBING FIXTURE OCCUPANCY FIXTURE COUNT PER OCCUPANCY FIXTURE COUNT CALC, PER 01 REQ. PROP OSED WATER CLOSETS - MEN / WOMEN B - BUS. 1 PER 25 FOR FIRST 50 8/25 = .32 0,398 1 M - MERC. 1 PER 500 39/500 = .078 LAVATORIES - MEN / WOMEN B - BUS. 1 PER 40 FOR FIRST 80 8/40 = .2 0.252 1 M - MERC. 1 PER 750 39/750 = .052 DRINKING FOUNTAIN B - BUS. 1 PER 100 8I100 = .08 0.119 2 M - MERC. 1 PER 1000 39/1000 = .039 SERVICE SINK 1 1 1 1 FLORIDA BUILDING CODE -403.2 SEPARATE FACILITIES. EXCEPTIONS: 3. SEPARATE FACILITIES SHALL NOT BE REQUIRED IN MERCANTILE OCCUPANCIES IN WHICH THE MAXIMUM OCCUPANT LOAD IS 100 OR FEWER. 4 I LIFE SAFETY PLAN SCHEDULES: EXISTING WALL TO REMAIN 0-- - - — MAXIMUM DISTANCE OF TRAVEL -- - - - ® COMMON PATH OF TRAVEL ODISTANCE TRAVELING EC, FE <( FIRE EXTINGUISHER S EXIT SIGNS EXIT# - r z'-10 -- WIDTH 1 ACTUAL 1ao ALLOWED 2 LIFE SAFETY PLAN LEGEND WIND DESIGN DATA V(ULT) 165 MPH V(ASD) 128 MPH RISK CATEGORY II WIND EXPOSURE C INTERNAL PRESSURE COEFFICIENT +/- .18 a 9 FT. COMPONENT & CLADDING PRESSURES (PSF) AREA ZONE 4 ZONE 5 POSITIVE NEGATIVE POSITIVE NEGATIVE 10 SF 67 -72 67 -89 20 SF 64 -69 64 -83 50 SF 60 -65 60 -75 100 SF 57 -62 57 -69 3/16" = 1'-Orl 2b WIND DESIGN DATA CEILING MOUNTED EXIT SIGN CENTERED ON DOOR EXIT m WALL MOUNTED EXIT SIGN FINISH 4,.-p. CEILING FIRE STROBE �- HANDLE ON FIRE THERMOSTAT EXTINGUISHER WHETHER NOTE: NO ACCESSORIES SHALL INSIDE CABINET OR BE LOCATED IN THE AREA THAT HANGING ON WALL IS 1 1@" BELOW GRAB BARS & 12" ABOVE GRAB BARS C I A. S E FINISH FLOOR - B NOTE: ALIGN ALL NEW DEVICES REGARDLESS OF LOCATION ON WALL NOTE: CONTRACTOR SHALL VERIFY THAT ALL RESTROOM ACCESSORIES COMPLY WITH ADA REQUIREMENTS. WHERE ACCESSORIES DO NOT COMPLY CONTRACTOR TO ADJUST I MODIFY AS REQUIRED. DIMENSIONS ARE TO CONTROLS OR OPENING OF DEVICE. Vill. FIRE PROTECTION REQUIREMENTS A. MANUAL FIRE ALARM BOXES: MIN. 5 FT. FROM EACH EXIT B. VISIBLE ALARMS REQUIRED IN PUBLIC AREAS N/A C. REFER TO MEP DOCUMENTS N/A D. FIRE EXTINGUISHER REQUIREMENTS PER: NFPA 10 (1-6) E. MAXIMUM AREA PER EXTINGUISHER: 11,250 SQ/ FT. F. MAXIMUM TRAVEL DISTANCE TO EXTINGUISHER: 75 FT. IX. HANDICAPPED ACCESSIBILITY REQUIREMENTS A. A MINIMUM 60" x 60" LANDING FOR DIRECTION CHANGE AT TOP OF RAMP. B. A MINIMUM 18" UNOBSTRUCTED MANEUVERING CLEARANCE ON PULL SIDE OF DOOR(S). C. A MINIMUM 12" UNOBSTRUCTED MANEUVERING CLEARANCE ON PUSH SIDE OF DOOR(S) IF DOOR HAS BOTH A CLOSER AND LATCH. D. ACCESSIBLE COUNTERlTRANSACTION SURFACE NO MORE THAN 36" A.F.F. E. A MINIMUM 36" WIDE REAR GRAB BAR. F. A MINIMUM 42" LONG SIDE GRAB BAR. G. LEVER HARDWARE ON NEW OR RE -HUNG DOORS. H. NO KEY LOCKS ON EGRESS SIDE OF DOOR. 5 GENERAL ADA CODES & MOUNTING HEIGHTS: FL# CATEGORY SUBCATEGORY MANUF 1537.1 EXT DOOR SWINGING EXIT DOOR ASSEMBLY CURRIES Q1537.2 EXT DOOR SWINGING EXIT DOOR ASSEMBLY CURRIES 1 * MEANS OF EGRESS DOORS SHALL COMPLY WITH FBC 1010.1 AND 1022.2 6 1 FLORIDA PRODUCT APPROVALS 1240 East 5th Avenue Tampa, FL 33605 T 813.223.2293 F 813.223.2433 www.asdsky.com TERRA WELLNESS U J Q U (V i V co Co LL � U n/ U J CO r Vi VJ � OIl Florida Business License #: AA26001572 Registered Architect: Kenneth Cowart Registered Architect License #: AR93215 This drawing is the property of Associated Space Design, Inc. and is not to be reproduced or copied in whole or part. It is not to be used on any other project and Is to be returned upon request. Scales as stated herein are for reference only as normal reproduction processes may alter the accuracy of original drawings. Associated Space Design, Inc. 2018 12 2 08-28-18 PERMIT COMMENTS 2 1 07-31-18 PERMIT COMMENTS NO. DATE REMARKS REVISIONS DRAWING TITLE: LIFE SAFETY PLAN PRODUCT 607 SERIES PROJECT NO.: ISSUE DATE: M SERIES METAL FRAME 51394.64 05-23-18 RECMED DRAWN BY: CHECKED BY: SEP 04 2010 AC KN SHEET NUMBER: v A0 ■ 1 ION 01100 GENERAL REQU 01100-1 ALL WORK SHALL BE PERFORMED IN CONFORMANCE WITH THE TERMS OF THE LEASE AND APPLICABLE BUILDING STANDARD SPECIFICATIONS. WORKMANSHIP AND MAINTAINING STANDARDS OF QUALITY SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR. THE CONTRACTOR SHALL PROVIDE ALL WORK SHOWN IN THE CONTRACT DOCUMENTS AND IS REQUIRED TO PROVIDE A COMPLETE, FINISHED INSTALLATION, UNLESS OTHERWISE NOTED. IT IS THE RESPONSIBILITY OF THE CONTRACTOR TO ACQUAINT HIMSELF WITH ALL SUCH TENANT AND BUILDING STANDARDS REGARDLESS OF WHETHER THEY HAVE BEEN SPECIFICALLY REFERENCED IN THESE DOCUMENTS OR NOT. 01100-2 THE CONTRACTOR SHALL ARRANGE FOR ELEVATOR OR OTHER HOISTING FACILITIES FOR MATERIALS AS WELL AS PARKING AND LOADING FACILITIES WITH THE BUILDING MANAGEMENT. THE CONTRACTOR SHALL PAY ALL COSTS FOR DELIVERY AND/OR HANDLING OF MATERIALS. 01100-3 ALL ARRANGEMENTS FOR CONSTRUCTION PERSONNEL ENTERING THE BUILDING DURING OR AFTER WORKING HOURS, MATERIALS DELIVERY, STORAGE, SECURITY, DEBRIS REMOVAL,, ETC., SHALL BE MADE WITH THE BUILDING MANAGEMENT. 01100.4 PRIOR TO CONSTRUCTION, THE CONTRACTOR, AND HIS SUBCONTRACTORS, SHALL PROVIDE UNIT PRICES FOR ALL WORK SHOWN. SUCH UNIT PRICING SHALL BE REQUIRED TO BE SUBMITTED PRIOR TO SUBMITTAL OF THE FIRST APPLICATION FOR PAYMENT, FAILURE TO SUBMIT THE UNIT PRICING SHALL BE CONSIDERED GROUNDS FOR REJECTION OF THE INITIAL APPLICATION FOR PAYMENT. SUCH UNIT PRICES SHALL BE GOOD FOR THE DURATION OF THE PROJECT AND SHALL BE USED AS THE BASIS FOR ALL CHANGES TO THE WORK. 01100-5 THE CONTRACTOR SHALL SCHEDULE AND PERFORM ALL WORK SO AS NOT TO DISTURB ANY TENANT IN THE BUILDING AND SHALL IDENTIFY ALL OVERTIME COSTS REQUIRED TO COMPLETE THE WORK IN HIS BID. 01100-6 THE CONTRACTOR SHALL PREPARE A COMPLETE CONSTRUCTION SCHEDULE TO INCLUDE WORK TO BE PERFORMED BY THE TENANT'S VENDORS (INCLUDING FURNITURE VENDORS) TO BE SUBMITTED WITHIN ONE WEEK OF AWARD OF THE CONTRACT. 01100-7 SUBSTITUTIONS SHALL BE ALLOWED ONLY IF THE SPECIFIED ITEMS CANNOT BE INSTALLED WITHIN THE TENANT'S MOVE -IN SCHEDULE AND ONLY WITH THE APPROVAL OF THE ARCHITECT. THE CONTRACTOR SHALL COORDINATE WITH THE ARCHITECT FOR SELECTION AND APPROVAL OF ALL SUBSTITUTED ITEMS PRIOR TO SUBMISSION OF HIS BID. IT IS THE CONTRACTOR'S RESPONSIBILITY TO ENSURE AND TO DEMONSTRATE THAT ALL SUBSTITUTIONS USED IN THE WORK COMPLY WITH THE CONTRACT DOCUMENTS. SHOULD A SUBSTITUTED PRODUCT FAIL TO PERFORM FOR ANY REASON, WHERE THE ORIGINALLY SPECIFIED PRODUCT WOULD HAVE, THE CONTRACTOR SHALL PERFORM ALL THE WORK NECESSARY TO INCORPORATE THE ORIGINALLY SPECIFIED PRODUCT AT NO ADDITIONAL COST. 01100-8 THE CONTRACTOR SHALL IMMEDIATELY ANALYZE THE CONTRACT DOCUMENTS AND REPORT ANY DISCREPANCIES TO THE ARCHITECT. THE CONTRACTOR SHALL BE REQUIRED TO CORRECT ANY DEFECTIVE WORK CAUSED BY WORK DONE AS A RESULT OF INCONSISTENCIES OR DISCREPANCIES IN THE DRAWINGS WHEN CLARIFICATION FROM THE ARCHITECT HAS NOT BEEN SOUGHT. 01100-9 ARCHITECTURAL DOCUMENTS SHALL HAVE PRECEDENCE OVER ENGINEERING DOCUMENTS. HOWEVER, BOTH SHALL BE REVIEWED AND COORDINATED BY THE CONTRACTOR. REPORT ANY DISCREPANCIES WITHIN THE DOCUMENTS TO THE ARCHITECT. 01100-10 DO NOT SCALE DIMENSIONS FROM THESE DRAWINGS. 01100-11 THE CONTRACTOR SHALL PROVIDE THE ARCHITECT WITH A SET OF REPRODUCIBLE AS -BUILT DOCUMENTS AT PROJECT CLOSEOUT. 01100-12 VERIFY FIELD CONDITIONS AND EXISTING LOCATIONS OF ALL PLUMBING, MECHANICAL DUCTS, STRUCTURAL ELEMENTS AND ANY AND ALL OTHER APPLICABLE ITEMS THAT MAY AFFECT THE PROJECT. INSTALL NEW PLUMBING, SPRINKLER LINES AND HEADS, MECHANICAL FANS, DUCTS SO AS TO NOT CONFLICT WITH LUMINARIES AND ANY AND ALL FIELD CONDITIONS. THE CONTRACTOR IS RESPONSIBLE FOR THE COORDINATION OF PLENUM ELEMENTS. ARRANGE OR MODIFY NON -VISIBLE ITEMS TO FIT CONDITIONS OR REFLECTED CEILING PLAN AS REQUIRED. ANY AND ALL COST RESULTING FROM CHANGES INCURRED TO ENSURE INTEGRITY OF THE REFLECTING CEILING PLAN LAYOUT SHALL BE BORN BY THE CONTRACTOR. 01100-13 THE CONTRACTOR SHALL COORDINATE ALL CONNECTIONS OF MECHANICAL, ELECTRICAL AND PLUMBING TO THE BASE BUILDING SYSTEMS WITH THE BUILDING MANAGEMENT. 01100-14 THE CONTRACTOR SHALL PERFORM ALL WORK IN SUCH A MANNER THAT A SHUTDOWN OF ANY UTILITIES, ALARM, SECURITY OR COMMUNICATIONS SYSTEMS SHALL NOT OCCUR WITHOUT THE CONSENT OF THE BUILDING MANAGEMENT. TIVE NOTES & S 01300-1 PROPOSAL REQUESTS ISSUED BY THE ARCHITECT ARE FOR INFORMATION ONLY. DO NOT CONSIDER THEM INSTRUCTION TO STOP WORK IN PROGRESS OR TO EXECUTE THE PROPOSED CHANGE UNTIL SPECIFICALLY INSTRUCTED TO DO SO BY THE ARCHITECT. 01300-2 UPON THE OWNER'S APPROVAL OF A PROPOSAL REQUEST, THE CONTRACTOR WILL ISSUE A CHANGE ORDER FOR SIGNATURES OF THE OWNER AND ARCHITECT ON AIA FORM G701, AS PROVIDED IN THE CONDITIONS OF THE CONTRACT. 01300-3 THE CONTRACTOR SHALL PREPARE A FULLY DEVELOPED, HORIZONTAL BAR -CHART TYPE CONSTRUCTION SCHEDULE. THE CONTRACTOR SHALL SUBMIT SUCH SCHEDULE WITHIN 7 CALENDAR DAYS OF'NOTICE TO PROCEED'. 01300.4 THE CONTRACTOR SHALL PREPARE AND SUBMIT A COMPLETE SCHEDULE OF SUBMITTALS WITHIN 14 CALENDAR DAYS OF'NOTICE TO PROCEED'. 01300-5 THE CONTRACTOR SHALL REVIEW, AND APPROVE DATA SUBMITTALS, SHOP DRAWINGS AND SAMPLES PRIOR TO SUBMITTING THEM TO THE ARCHITECT. THE ARCHITECT SHALL NOT BE OBLIGATED TO REVIEW AND RETURN SUBMITTALS WITHOUT PROPER CONTRACTOR REVIEW. 01300-6 THE CONTRACTOR SHALL COORDINATE THE PREPARATION AND PROCESSING OF SUBMITTALS WITH THE PERFORMANCE OF THE WORK SO THAT THE WORK WILL NOT BE DELAYED BY SUBMITTALS INCLUDING THE TIME REQUIRED FOR RESUBMITTALS. 01300-7 THE CONTRACTOR SHALL NOT BE RELIEVED OF RESPONSIBILITY FOR ANY ERRORS, OMISSIONS OR DEVIATION FROM THE REQUIREMENTS OF THE CONTRACT DOCUMENTS BY THE ARCHITECT'S REVIEW OF SHOP DRAWINGS, PRODUCT DATA OR SAMPLES. 01300-8 ALLOW 14 DAYS FOR INITIAL SUBMITTAL REVIEW. ALLOW 7 DAYS FOR REPROCESSING EACH SUBMITTAL. 01300-9 NO EXTENSION OF CONTRACT TIME WILL BE AUTHORIZED BECAUSE OF FAILURE TO TRANSMIT SUBMITTALS TO THE ARCHITECT SUFFICIENTLY IN ADVANCE OF THE WORK TO PERMIT PROCESSING. 01300.10 SUBMITTALS SHALL BE TRANSMITTED FROM CONTRACTOR TO ARCHITECT USING A TRANSMITTAL FORM. ON THE TRANSMITTAL RECORD RELEVANT INFORMATION AND REQUEST FOR DATA. ON THE FORM, OR SEPARATE SHEET, RECORD DEVIATIONS FROM CONTRACT DOCUMENT REQUIREMENTS, INCLUDING MINOR VARIATIONS AND LIMITATIONS. INCLUDE CONTRACTOR'S CERTIFICATION THAT INFORMATION COMPLIES WITH CONTRACT REQUIREMENTS. ALL SHOP DRAWINGS MUST BE CROSS REFERENCED TO ARCHITECTURAL DRAWINGS. 01300.11 PRODUCT DATA: SUBMIT 1 COPY OF EACH REQUIRED SUBMITTAL IN PDF FORMAT VIA EMAIL TO THE ARCHITECT. THE ARCHITECT AND ENGINEER OR APPROPRIATE CONSULTANT WILL REVIEW THE SUBMITTAL AND WILL RETURN THE REVIEWED DOCUMENT, CONTAINING ALL CORRECTION AND COMMENT MARKS, IN PDF FORMAT VIA EMAIL. ALL EMAILED SUBMITTALS SHALL BE NO LARGER THAN 5MB IN SIZE IN ORDER TO ENSURE DELIVERY THROUGH ALL EMAIL SERVERS. 01300-12 PRODUCT SAMPLES: SUBMIT 3 FULL SIZE, FULLY FABRICATED SAMPLES CURED AND FINISHED AS SPECIFIED AND PHYSICALLY IDENTICAL WITH THE MATERIAL OR PRODUCT PROPOSED. SAMPLES INCLUDE PARTIAL SECTIONS OR MANUFACTURED OR FABRICATED COMPONENTS, CUTS OR CONTAINERS OF MATERIALS, COLOR RANGE SETS, AND SWATCHES SHOWING COLOR, TEXTURE AND PATTERN. 01300-13 PRODUCT ASSEMBLY SAMPLES: SUBMIT 1 SAMPLE FOR THOSE SUBMITTALS ILLUSTRATING ASSEMBLY DETAILS, WORKMANSHIP, FABRICATION TECHNIQUES, CONNECTIONS, OPERATION AND SIMILAR CHARACTERISTICS. 01300-14 SHOP DRAWINGS SHALL SHOW COORDINATION WITH ASSOCIATED ADJACENT TRADES. FAILURE TO DO SO SHALL BE GROUNDS FOR REJECTION OF THE SHOP DRAWINGS. SUBMIT 1 COPY OF SHOP DRAWINGS IN PDF FORMAT VIA EMAIL TO THE ARCHITECT. THE ARCHITECT WILL REVIEW AND WILL RETURN THE REVIEWED DOCUMENT, CONTAINING ALL CORRECTION AND COMMENT MARKS, IN PDF FORMAT VIA EMAIL. ALL EMAILED SUBMITTALS SHALL BE NO LARGER THAN 5MB IN SIZE TO ENSURE DELIVERY THROUGH ALL EMAIL SERVERS. FULL SIZE PDF DOCUMENTS WILL BE ACCEPTED IN PAPER SIZES UP TO 30"X42". 01300.16 THE CONTRACTOR SHALL BE RESPONSIBLE FOR ADDITIONAL FEES AND EXPENSES TO BE PAID TO ASD IN THE EVENT THAT MORE THAN 2 FINAL INSPECTIONS AND CORRESPONDING PUNCH LISTS ARE REQUIRED TO COMPLETE THE WORK. THE COST OF THE ADDITIONAL FEES AND EXPENSES SHALL BE PAID BY THE CONTRACTOR AND SHALL BE DEDUCTED FROM THE CONTRACTOR'S PAY APPLICATION. FEES AND EXPENSES SHALL INCLUDE NORMAL HOURLY BILLING RATES, REPRODUCTION AND TRANSPORTATION COSTS. 01300-16 SAMPLES, SHOP DRAWINGS AND PRODUCT DATA REQUIRED TO BE SUBMITTED ARE LISTED ON THE SUBMITTAL SCHEDULE. SUB ITTAL SCHEDULE SHOP DWGS SAMPLES LITERATURE OTHER MILLWORK X X DOORS AND FRAMES X X SCHEDULE HAR WARE X X X SCHEDULE PAIN X WALLCOVERING X CEILIl IG TILE X X WALL BASE X FLOORING (CARPET, TILE, ETC.) X FABR C WALL PANELS X X X MECF ANICAL X ELEC rRICAL LIGH ING X POW R X COVE R PLATES X SWIT "HES X OUTL ETS X GLAZ NG X X APPLIANCES X FIRE OXTINGUSHER CABINETS X PRO ECTION SCREENS X PLU BING X SPRI KLER SYSTEM X SECTION 01405 GENERAL ENVIRONMENTAL REQUIREMENTS 01405-1 SUSTAINABI ITY GOALS FOR THE PROJECT WILL FOLLOW THE BEST PRACTICES OF LEED FOR COMMERCIAL INTERIORS. 01405-2 THE TENAN HAS ESTABLISHED THE FOLLOWING ENVIRONMENTAL GOALS FOR THE PROJECT. NOTIFY TENANT AND ARCHITECT IF CONFLICTS ARISE BETWEEN PERFORMANCE OF THE WORK AND ENVIRONMENTAL GOALS. THIS SPECIFICATION IS NOT INTENDED TO LIMIT ALTERNATIVE MEANS OF ACHIEVING THESE GOALS. SUGGESTIONS AND INPUT FROM THE CONTRACTOR(S) FOR IMPLEMENTING THESE GOALS ARE ENCOURAGED. A. USE RESOURCES EFFICIENTLY: THE CONSTRUCTION, OPERATION AND ULTIMATELY REUSE OR REMOVAL OF THE BUILDING SHOULD BE OPT MIZED TO ELIMINATE UNNECESSARY USE OF ENERGY, WATER AND RAW MATERIALS. B. PROVIDE A HEALTHY AND PRODUCTIVE INDOOR ENVIRONMENT. C. ENH NCE, RESTORE, AND PROTECT THE GLOBAL ENVIRONMENT. 1. INIMIZE THE RELEASE OF CARBON DIOXIDE (CO2) FROM FUELS BURNED ON SITE OR FUELS BURNED OFF SITE TO SUPPLY LECTRICITY TO THE BUILDING. 2. VOID THE RELEASE OF OZONE -DEPLETING COMPOUNDS, SUCH AS HCFCS FROM REFRIGERANTS OR FOAM NSULATION MATERIALS. 3. ELECT BUILDING MATERIALS THAT, BASED ON AN OVERALL LIFE -CYCLE ASSESSMENT, ARE THE LEAST DAMAGING TO THE NVIRONMENT IN THEIR EXTRACTION, PROCESSING, USE, AND ULTIMATE DISPOSAL. 01406-3 MATERIAL c ELECTION AND CONSTRUCTION PROCESS GOALS: IN SUPPORT OF THE OVERALL GOALS LISTED ABOVE THE FOLLOWING HAVE BEEN IDENTIFIED zOR THE MATERIAL SELECTION AND CONSTRUCTION PROCESS. THESE ARE ALSO GENERAL IN NATURE AND SHOULD BE CONSIDERED AS A GUIDE INE. IN THE EVENT OF A CONFLICT, ANY SPECIFIC REQUIREMENTS IN TECHNICAL SPECIFICATION SECTIONS TAKE PRECEDENCE. TRADEOFFS AND COMPROMISES ARE INEVITABLE IN THE PURSUIT OF THESE GOALS, BUT EVERYONE WORKING ON THE PROJECT IS EXPECTED TO TAKE ALL R EASONABLE ACTIONS TO FURTHER THESE GOALS. NOTIFY TENANT AND ARCHITECT OF ANY PERFORMANCE REQUIREMENTS THAT CONFLICT L NNECESSARILY WITH THESE GOALS. A. USE RE OURCES EFFICIENTLY 1. USE CONSTRUCTION PRACTICES THAT ACHIEVE THE MOST EFFICIENT USE OF RESOURCES AND MATERIALS. 2. RECYCLE OR REUSE JOB -SITE WASTE, 3. PR VIDE MATERIALS WITH RECYCLED -CONTENT. 4. PR VIDE SALVAGED, REFURBISHED OR REUSED MATERIALS WHERE POSSIBLE W/O COMPROMISING QUALITY OF WORK. 5. PRC VIDE MATERIALS THAT ARE REPLACEABLE, RENEWABLE, OR CAN BE REPLENISHED. B. PROVIDE MATERIALS WITH THE LONGEST USABLE LIFE. 1. PROVIDE MATERIALS THAT CAN BE REUSED. 2. PROVIDE MATERIALS WITH THE LEAST BURDENSOME MAINTENANCE REQUIREMENTS. C. TENANI SPACE WILL BE CREATED HEALTHY FOR OCCUPANTS. 1, PROVIDE LOW-VOC PRODUCTS AND MATERIALS. 2, ALL MAINTENANCE REQUIREMENTS SHALL USE LOW-VOC PRODUCTS AND METHODS. 3. MECHANICAL EQUIPEMENT WILL PROVIDE FRESH AIR AND WILL NOT TRAP WATER OR POLLUTANTS. D. USE EN ERGY EFFICIENTLY: 1. PROVIDE MATERIALS THAT SAVE ENERGY DURING BUILDING OPERATIONS. 2. PROVIDE PRODUCTS AND EQUIPMENT THAT SAVE ENERGY DURING BUILDING OPERATIONS. E. USE W TER EFFICIENTLY: 1. USE CONSTRUCTION PRACTICES THAT ACHIEVE THE MOST EFFICIENT USE OF WATER. 2. PR VIDE WATER -CONSERVING APPLIANCES AND EQUIPMENT. F. FIR E MATERIALS THAT GENERATE THE LEAST AMOUNT OF POLLUTION. CONSIDER POLLUTION AND TOXINS GENERATED DURING HARVE TING, MINING, MANUFACTURING, TRANSPORT, INSTALLATION, USE, AND DISPOSAL. 01405-4 CONTRACT R SHALL DESIGNATE AN ON -SITE PARTY (OR PARTIES) RESPONSIBLE FOR INSTRUCTING WORKERS AND OVERSEEING THE ENVIRONMENTAL GOALS FOR THE PROJECT. THE CONTRACTOR SHALL DISTRIBUTE COPIES OF THE ENVIRONMENTAL GOALS TO THE JOB -SITE FOREMAN, EEACH SUBCONTRACTOR, THE OWNER, AND THE ARCHITECT, ENVIRONMENTAL GOALS SHALL BE DISCUSSED AT THE FOLLOWING MEETINGS: A. PRE -BID MEETING B. PRE -CC NSTRUCTION MEETING C. REGU R JOB -SITE MEETINGS SECTION 01524 CONSTRUCTION WASTE MANAGEMENT 01524-1 THE CON RACTOR SHALL CREATE AND IMPLEMENT A WASTE MANAGEMENT PLAN TO REDUCE AND RECYCLE CONSTRU TION WASTE. 01524-2 CONSTRU TION WASTE MANAGEMENT GOALS FOR THE PROJECT: A. SEPAF ATE RECYCLE AS MANY OF THE WASTE MATERIALS AS ECONOMICALLY FEASIBLE. B. DIVER 31ON GOALS: A MINIMUM OF 50% OF TOTAL PROJECT WASTE SHALL BE DIVERTED FROM LANDFILL. 01, CLEAN DIMENSIONAL WOOD, PALLET WOOD. NOTE WOOD SHALL BE SORTED BY TYPE AND SIZE FOR SALVAGE. WOOD UNSUITABLE FOR SALVAGE MAYBE CHIPPED OR SHREDDED FOR USE AS GROUND COVER, MULCH, COMPOST, PULP, OR PROCESS FUEL; DO NOT CHIP OR SHRE D STAINED, PAINTED, OR TREATED WOOD. SALVAGED WOOD MAY BE SUITABLE FOR MANUFACTURING OF PARTICLEBOARD AND OTHER COM OSITE WOOD PRODUCTS IN SOME LOCATIONS. DAMAGED WOOD MAYBE USED AS BRACING, BLOCKING, ETC. 02, PLYWOOD, OSB, AND PARTICLEBOARD 03. CONCRETE 04. CARDBOARD, PAPER, PACKAGING 05. 06, M GYPSUM ETALS DRYWALL (UNPAINTED); NOTE: ONLY CLEAN, UNPAINTED, NON -BIOCIDE -TREATED, GYPSUM BOARD MAY BE RECYCLED INTO NEW DRYWALL. 07, PAINT 08. G SS a. SEPARATE TEMPERED GLASS FOR USE AS AGGREGATE OR NON-STRUCTURAL FILL. 09, PIASTICS 10, CARPET a. ARRANGE FOR CARPET MANUFACTURER TO TAKE BACK REMOVED PRODUCTS FOR REUSE OR RECYCLING. b. SET ASIDE AND PROTECT OFF CUTS AND REMAINDER GREATER THAN 1 SQ. YD. FOR REUSE BY TENANT OR NONPROFIT ORGANIZATIONS SUCH AS HABITAT FOR HUMANITY 11. BEVERAGE CONTAINERS 12, BUILDING COMPONENTS AND FIXTURES: SALVAGE, DOORS, CABINETS, HARDWARE, ELECTRICAL AND PLUMBING FIXTURES. PORCELAIN P UMBING FIXTURES UNSUITABLE FOR SALVAGE MAY BE CRUSHED FOR FILL, 01524-3 PRIOR TO ANY WASTE REMOVAL, THE CONTRACTOR SHALL SUBMIT TO THE CLIENT A WASTE MANAGEMENT PLAN. THE PLAN SHALL CONTAIN THE FOLLOWING: A. DESIGNATION OF THE PARTY WHO WILL IMPLEMENT THE PLAN. B. ANALYSIS OF THE ESTIMATED JOB -SITE WASTE TO BE GENERATED, INCLUDING TYPES AND QUANTITIES C. PROPOSED ALTERNATIVES TO LANDFILLING: A LIST OF EACH MATERIAL PLANNED TO BE SALVAGED OR RECYCLED DURING THE COURSE OF THE PROJECT AND THE PROPOSED DESTINATION OF EACH MATERIAL. 01624-4 SUBMIT MONTHLY, A WASTE MANAGEMENT PROGRESS REPORT. THE REPORT SHALL CONTAIN THE FOLLOWING INFORMATION: A. PROJECT TITLE, NAME OF COMPANY COMPLETING REPORT, AND DATES OF PERIOD COVERED BY THE REPORT. B. AMOUNT (IN TONS OR CUBIC YARDS) OF TOTAL WASTE GENERATED C. FOR EACH MATERIAL RECYCLED OR SALVAGED FROM THE PROJECT, PROVIDE THE FOLLOWING: 1. AMOUNT (IN TONS OR CUBIC YARDS) 2. DATE(S) REMOVED FROM THE JOB SITE 3. RECEIVING PARTY 4. COST: BIN RENTAL, HAULING, AND FACILITY FEES 5. WHAT WAS DONE WITH THE MATERIAL D. INCLUDE LEGIBLE COPIES OF ON -SITE LOGS, MANIFESTS, WEIGHT TICKETS, AND RECEIPTS, MANIFESTS SHALL BE FROM RECYCLING AND/OR DISPOSAL SITE OPERATORS WHO CAN LEGALLY ACCEPT THE MATERIALS FOR THE PURPOSE OF REUSE, RECYCLING, OR DISPOSAL. E. AMOUNT (IN TONS OR CUBIC YARDS) MATERIAL DISPOSED OF TO LANDFILL. 01524.5 WASTE MANAGEMENT PLANS AND IMPLEMENTATION SHALL BE DISCUSSED AT THE FOLLOWING MEETINGS: A. PRE -BID MEETING B. PRE -CONSTRUCTION MEETING C. REGULAR JOB -SITE MEETINGS 01524-6 IMPLEMENT WASTE MANAGEMENT PLAN BY PROVIDING THE FOLLOWING: A. COORDINATE WASTE MATERIALS HANDLING AND SEPARATION FOR ALL TRADES, AND DOCUMENT RESULTS OF THE WASTE MANAGEMENT PLAN. B. PROVIDE SEPARATION, HANDLING, TRANSPORTATION, RECYCLING, SALVAGE, AND LANDFILLING FOR ALL DEMOLITION AND WASTE MATERIALS. C. DESIGNATE A SPECIFIC AREA FOR SEPARATION OF MATERIAL FOR SALVAGE AND RECYCLING. RECYCLING AND WASTE BINS AREAS ARE TO BE KEPT NEAT AND CLEAN AND CLEARLY MARKED IN ORDER TO AVOID CONTAMINATION OR MIXING MATERIALS. D. MAINTAIN AN ON -SITE LOG, WHICH INCLUDES FOR EACH LOAD OF MATERIALS REMOVED FROM SITE: TYPE OF MATERIAL, LOAD VOLUME AND/OR WEIGHT, RECYCLING / HAULING SERVICE, DATE ACCEPTED BY RECYCLING SERVICE OR LANDFILL, AND FACILITY FEE. E. DO NOT HANDLE, SEPARATE, STORE, SALVAGE, OR RECYCLE HAZARDOUS MATERIALS WITH OTHER MATERIALS. FOLLOW MATERIAL -SPECIFIC INSTRUCTIONS ON ANY HAZARDOUS MATERIALS. CONTACT PROJECT MANAGER OR ARCHITECT IF NO INSTRUCTIONS ARE EVIDENT. SECTION 06000 MILLWORK 06000-1 EXCEPT AS OTHERWISE SHOWN OR SPECIFIED, COMPLY WITH PROVISIONS OF THE ARCHITECTURAL WOODWORK INSTITUTE (AWI) "QUALITY STANDARDS, MOST RECENT EDITION. WORK SHALL BE PERFORMED IN THE HIGHEST GRADE APPLICABLE. 06000-2 SPECIFIC ITEMS: A. STANDING AND RUNNING TRIM WITH OPAQUE FINISH: AWI STANDARD 300 B. CASEWORK W/TRANSPARENT FINISH :AWI STANDARD 400 & 400A C. PLASTIC LAMINATE CLAD CABINETS:AWI STANDARD 400 & 400B D. ARCHITECTURAL COUNTERTOPS: AWI STANDARD 400 & 400C E. LUMBER: AWI STANDARD 100 F. PANELING: AWI STANDARD 500 G. SHELVING: AWI STANDARD 600, CUSTOM GRADE H. MISCELLANEOUS WORK: AWI STANDARD 700 I. ARCHITECTURAL FLUSH DOORS: AWI STANDARD 1300 J. STILE AND RAIL DOORS: AWI STANDARD 1400 K. FACTORY FINISHING: AWI STANDARD 1500 L. INSTALLATION OF ARCHITECTURAL WOODWORK: AWI STANDARD 1700 06000-3 CABINET CONSTRUCTION STYLE SHALL BE'FLUSH OVERLAY' AS PER AWI STANDARDS. 06000-4 ALL VENEERS SHALL BE AWI PREMIUM GRADE. ALL TRANSPARENT AND SEMI- TRANSPARENT MILLWORK SHALL BE AWI PREMIUM GRADE, ALL PLASTIC LAMINATE WORK SHALL BE AWI CUSTOM GRADE. HOWEVER, PLASTIC LAMINATE EDGE BANDING SHALL BE APPLIED PRIOR TO FACE LAMINATE. THIS REQUIREMENT SUPERSEDES AWI STANDARDS. 06000.5 MACHINING PLASTIC PRODUCTS PRODUCES HAZARDOUS DUST. PROTECT SURROUNDING AREAS FROM DUST. PROTECT SURROUNDING AREAS FROM DUST. WEAR APPROPRIATE PROTECTION. 06000-6 REFER TO FINISH LEGEND FOR SPECIFIED WOOD VENEER SPECIES, CUT AND FLITCH NUMBER. CONFIRM WITH ARCHITECT OF THE FOLLOWING: VENEERS LEAVES SHALL BE LAID UP ON PANELS AS (BOOK or SLIP or RANDOM) MATCHED. THE FACE OF EACH PANEL SHALL BE (BALANCED or CENTER BALANCED). VERTICAL MATCHING OF ADJACENT VENEER LEAVES SHALL BE (BOOK or SLIP) END MATCHED, VENEERED PANELS SHALL BE (SEQUENCED or BLUEPRINT) MATCHED. SOFFITS RECIEVING VENEER SHALL BE (WATERFALL) MATCHED AND COORDINATED WITH ALL ADJACENT VENEERED SURFACES. SEMI- TRANSPARENT AND TRANSPARENT FINISHES SHALL BE AWI #2, CATALYZED LACQUER, UNLESS NOTED OTHERWISE. SHEEN LEVEL SHALL BE MEDIUM RUBBED EFFECT, 40 DEGREES. STAIN COLOR TO MATCH THE ARCHITECT'S SAMPLE. ALL STAIN GRADE WOOD SHALL BE SANDED USING 150 GRIT GARNET OPEN COAT. THIS REQUIREMENT SUPERSEDES AWI STANDARDS. 06000-7 PROVIDE 3 FINISHED SAMPLES OF EACH TYPE OF TRIM AND WOOD VENEER TO BE USED ON THE PROJECT. 06000-8 INSTALL STANDING AND RUNNING TRIM WITH MINIMUM NUMBER OF JOINTS POSSIBLE, USING FULL LENGTH PIECES. COPE AT RETURNS AND MITER AT CORNERS. SCRIBE SMOOTH AT JAMB CONDITIONS, NO EXPOSED CUTS WILL BE ACCEPTABLE, 06000-9 DO NOT DELIVER OR INSTALL MILLWORK UNTIL CONDITIONS FOR TEMPERATURE AND RELATIVE HUMIDITY HAVE BEEN STABILIZED AND WILL BE MAINTAINED IN STORAGE AND INSTALLATION AREAS DURING THE REMAINDER OF CONSTRUCTION PERIOD TO COMPLY WITH THE AWI QUALITY STANDARD SECTION 100-G-4 & 100-T-11 "MOISTURE CONTENT," APPLICABLE TO THE PROJECT'S GEOGRAPHICAL LOCATION. CONDITION MILLWORK TO AVERAGE PREVAILING HUMIDITY IN INSTALLATION AREA PRIOR TO HANGING. 06000-10 PROTECT WOOD PRODUCTS AND MATERIALS FROM DAMAGE AND MOISTURE DURING DELIVERY, INSTALLATION, AND USE. 06000.11 PROVIDE SHOP DRAWINGS SHOWING THE LOCATION OF EACH ITEM, DIMENSIONED PLANS, ELEVATIONS, SECTIONS, LARGE SCALE DETAILS, ATTACHMENT DEVICES AND ALL OTHER COMPONENTS. 06000-12 CHECK ACTUAL DIMENSIONS OF OTHER CONSTRUCTION WHERE MILLWORK MUST FIT BY ACCURATE FIELD MEASUREMENTS PRIOR TO FABRICATION OF THE WORK. 06000-13 TO THE GREATEST DEGREE POSSIBLE, FINISH ARCHITECTURAL WOODWORK AT THE FACTORY OR MILLWORK SHOP. DEFER ONLY FINAL TOUCH UP, CLEANING AND POLISHING UNTIL AFTER INSTALLATION. 06000-14 INSTALL MILLWORK PLUMB, LEVEL AND STRAIGHT. SHIM AS REQUIRED WITH CONCEALED SHIMS. PROVIDE A MAXIMUM TOLERANCE OF 1/8" IN 8'-0" FOR PLUM AND LEVEL. SCRIBE AND CUT MILLWORK TO FIT ADJOINING WORK AND REFINISH CUT SURFACES. 06000-15 ADJUST HARDWARE TO CENTER DOORS AND DRAWERS IN OPENINGS AND TO PROVIDE UNENCUMBERED OPERATION, 06000-16 JOINTS FOR STONE TOPS SHALL BE BUTT JOINTS WITH MINIMAL SEALANT EXPOSED. 06000-17 CABINET HARDWARE: A. HARDWARE TO COMPLY WITH ANSI A156.9, 'AMERICAN NATIONAL STANDARD FOR CABINET HARDWARE.' B. HINGES SHALL BE PROPER NUMBER PER LEAF AS NOTED IN MANUFACTURER'S LOAD CHARTS, BUT NOT LESS THAN 3 PER LEAF, PROVIDE FULL OR HALF OVERLAY AS REQUIRED. PROVIDE SPRING LOADED HINGES FOR EASE OF DOOR OPERATION. BASIS OF DESIGN SHALL BE BLUM MODEL 90,170 DEGREE OPENING CONCEALED HINGES. C. DRAWER GLIDES SHALL BE K & V OR EQUAL BY GRANT OR ACCURIDE OF CORRECT SIZE FOR DRAWER DEPTH. PROVIDE SIDE PAIR 100 LB. RATED BALL BEARING ROLLERS 1/2" WIDE UNITS W/FULL EXTENSION. D. SILENCERS SHALL BE 1/4" DIAMETER RUBBER. ASD SKY 1240 East 5th Avenue Tampa, FL 33605 T 813.223.2293 F 813.223.2433 www.asdsky.com IIIQSUF�TERRA N uO M P M M J ILL s 0U 2 � U) J CO CO-t r®ao 4 M N This drawing is the property of Associated Space Design, Inc. and is not to be reproduced or copied in whole or part. It is not to be used on any other project and is to be returned upon request. Scales as stated herein are for reference only as normal reproduction processes may alter the accuracy of original drawings. Associated Space Design, Inc. 2018 NO: DATE: REMARKS: REVISIONS: DRAWING TITLE: SPECIFICATIONS 51394.64 AC 05-23-18 11. A0.11 KN 1 SECTION 07800 FIRE STOPPING 07800-1 FIRE STOPPING SHALL COMPLY WITH THE STANDARDS REQUIRED BY ASTM E814-88 "STANDARD TEST METHOD FOR FIRE TESTS OF THROUGH - PENETRATION FIRE STOPS" AND SHALL COMPLY WITH UL 1479 "FIRE TESTS OF THROUGH -PENETRATION FIRESTOPS." 07800-2 FIRE STOPPING SYSTEMS SHALL CONFORM TO BOTH FLAME (F) AND TEMPERATURE (T) RATINGS AS REQUIRED BY LOCAL BUILDING CODE AND AS TESTED BY NATIONALLY ACCEPTED TEST AGENCIES PER ASTM E814 AND UL 1479 FIRE TESTS IN A CONFIGURATION THAT IS REPRESENTATIVE OF FIELD CONDITIONS. THE FIRE RATING MUST BE A MINIMUM OF ONE HOUR, BUT NOT LESS THAT THE FIRE RESISTANCE RATING OF THE ASSEMBLY BEING PENETRATED. T RATING, WHEN REQUIRED BY CODE AUTHORITY, SHALL BE BASED ON MEASUREMENT OF THE TEMPERATURE RISE ON PENETRATING ITEMS. THE FIRE TEST SHALL BE CONDUCTED WITH A MINIMUM POSITIVE PRESSURE DIFFERENTIAL OF 0.01" OF WATER COLUMN. 07800-3 FIRE STOPPING SHALL BE INSTALLED IN ALL OPENINGS IN FIRE -RATED FLOOR AND WALL ASSEMBLIES, BOTH BLANK (EMPTY) AND THOSE ACCOMMODATING PENETRATING ITEMS SUCH AS CABLES, CONDUITS, PIPES, DUCTS, ETC. 07800-4 FIRE STOPPING MATERIALS AND SYSTEMS SHALL BE CAPABLE OF CLOSING OR FILLING THROUGH OPENINGS CREATED BY THE BURNING OR MELTING OF COMBUSTIBLE PIPES, CABLE JACKETING, OR PIPE INSULATION MATERIALS, OR OPENINGS CREATED BY DEFLECTION OF SHEET METAL DUE TO THERMAL EXPANSION (ELECTRICAL OR MECHANICAL DUCTWORK). 07800-5 FIRE STOPPING MATERIAL SHALL BE ASBESTOS -FREE AND SHALL NOT INCORPORATE NOR REQUIRE THE USE OF HAZARDOUS SOLVENTS. 07800-6 FIRE STOPPING MATERIALS SHALL NOT SHRINK UPON DRYING AS EVIDENCED BY CRACKING OR PULLING BACK FROM CONTACT SURFACES. 07800-7 DO NOT USE ANY FIRE STOP PRODUCTS WHICH, AFTER CURING, DISSOLVE IN WATER. 07800-8 SUBMIT DOCUMENT FROM FIRE STOP MANUFACTURER WHEREIN MANUFACTURER RECOGNIZES AND APPROVES INSTALLER FOR SAID MANUFACTURER'S FIRE STOP PRODUCTS. 07800-9 FIRE STOP MATERIAL SHALL BE DELIVERED IN THE MANUFACTURER'S ORIGINAL, UNOPENED CONTAINERS OR PACKAGES WITH THE MANUFACTURER'S NAME, PRODUCT IDENTIFICATION, LOT NUMBER, UL LABEL, AND MIXING AND INSTALLATION INSTRUCTIONS AS APPLICABLE 07800-10 MATERIALS SHALL BE STORED IN THE ORIGINAL, UNOPENED CONTAINERS OR PACKAGES, AND UNDER CONDITIONS RECOMMENDED BY THE MANUFACTURER. 07800-11 EXAMINE THE AREAS AND CONDITIONS WHERE FIRE STOPS ARE TO BE INSTALLED AND NOTIFY THE ARCHITECT OF CONDITIONS DETRIMENTAL TO THE PROPER AND TIMELY COMPLETION OF THE WORK. DO NO PROCEED WITH WORK UNTIL UNSATISFACTORY CONDITIONS HAVE BEEN CORRECTED BY THE CONTRACTOR IN A MANNER ACCEPTABLE 07800-12 INSTALLATION SHALL CONFORM TO THE MANUFACTURER'S PRINTED INSTRUCTIONS FOR INSTALLATION AND, WHEN APPLICABLE, CURING IN ACCORDANCE WITH TEMPERATURE AND HUMIDITY. CONFORM TO VENTILATION AND SAFETY REQUIREMENTS. 07800-13 INSTALLATION OF FIRE STOPS SHALL BE PERFORMED BY AN APPLICATOR/INSTALLER QUALIFIED AND TRAINED BY THE MANUFACTURER. INSTALLATION SHALL BE PERFORMED IN STRICT ACCORDANCE WITH MANUFACTURER'S DETAILED INSTALLATION PROCEDURES. 07800-14 CONTRACTOR SHALL COORDINATE FIRE STOPPING WORK AS REQUIRED WITH THE WORK OF OTHER TRADES. FIRE STOPPING SHALL PRECEDE GYPSUM BOARD FINISHING. 07800.15 WHERE FIRE STOPPING IS INSTALLED AT LOCATIONS WHICH REMAIN EXPOSED TO THE COMPLETED WORK, PROTECTION SHALL BE PROVIDED AS NECESSARY TO PREVENT DAMAGE TO ADJACENT SURFACES AND FINISHES, AND PROTECT AS NECESSARY AGAINST DAMAGE FROM OTHER CONSTRUCTION ACTIVITIES. 07800-16 INSTALLATION OF FIRE STOPPING SYSTEMS SHALL BE PERFORMED BY A CONTRACTOR TRAINED OR APPROVED BY THE FIRE STOP MANUFACTURER. 07800-17 LEAVE FINISHED WORK IN NEAT, CLEAN CONDITION, WITH NO EVIDENCE OF SLIPOVERS OR DAMAGE TO ADJACENT SURFACES, SECTION 08100 HOLLOW METAL DOOR FRAMES 08100-1 PROVIDE AND INSTALL HOLLOW METAL COMPLYING WITH THE APPLICABLE REQUIREMENTS OF THE FOLLOWING PUBLICATIONS A. AIA PAMPHLET NO. 80 B. NBHA (NATIONAL BUILDERS HARDWARE ASSOCIATION) C. NFPA STANDARD NO. 80 D. P.S. (PRODUCT STANDARD) 4-66 E. SDI (STEEL DOOR INSTITUTE) NO. 100 AND 105 F. UL STANDARD FOR SAFETY NO. 63 G. UL GUIDE 120 I.D.O. H. NAAM STANDARD CHM-1 08100-2 FIRE -RATED DOOR ASSEMBLY UNITS SHALL COMPLY WITH NFPA NO. 80. THEY SHALL BE IDENTICAL TO DOOR AND FRAME ASSEMBLIES WHOSE FIRE RESISTANCE CHARACTERISTICS HAVE BEEN DETERMINED PER ASTM E 152 AND WHICH ARE LABELED AND LISTED BY UL, FACTORY MUTUAL, WARNOCK HERSEY, OR OTHER TESTING AND INSPECTING ORGANIZATIONS ACCEPTABLE TO AUTHORITIES HAVING JURISDICTION. 08100-3 PROVIDE FIRE -RATED HOLLOW METAL FRAMES INVESTIGATED AND TESTED AS A FIRE DOOR ASSEMBLY, COMPLETE WITH TYPE OF FIRE DOOR HARDWARE TO BE USED. IDENTIFY EACH FIRE DOOR FRAME WITH UL LABELS, INDICATING APPLICABLE FIRE RATING OF FRAME. 08100-4 PROVIDE METAL FRAMES FOR DOORS OF TYPES AND STYLES AS SHOWN ON DRAWINGS AND SCHEDULES. CONCEAL FASTENINGS UNLESS OTHERWISE NOTED, FABRICATE FRAMES OF MINIMUM 18-GAUGE COLD -ROLLED STEEL. 08100-5 FRAMES SHALL COMPLY WITH ASTM A366. FURNISH FRAMES WITH FIXED STRIPS BUTTED. USE ROLLED SECTIONS FOR FIRE -RATED OPENINGS, PROVIDE UL ANCHORS FOR FIRE- RATED OPENINGS, STRAP ANCHORS AT WOOD OR METAL STUDS, AND OTHER TYPES AS INDICATED OR AS APPROVED FOR CONDITIONS OF USE. 08100-6 FRAMES SHALL BE FABRICATED WITH WELDED MITERED CORNERS. 08100-7 PROVIDE HOLLOW METAL WORK AS MANUFACTURED BY ONE OF THE FOLLOWING A. ALLIED STEEL PRODUCTS B. AMERICAN STEEL PRODUCTS CORP. C. AMERICAN WELDING AND MFG. CO. D. GATEWAY METAL PRODUCTS E. OVERLY MFG. CO. F. TEX-STEEL CORPORATION G. TRUSSBILT 08100-8 SUBMIT DATA FOR EACH TYPE OF FRAME SPECIFIED, INCLUDING DETAILS OF CONSTRUCTION, MATERIALS, DIMENSIONS, HARDWARE PREPARATION, CORE, LABEL COMPLIANCE, SOUND RATINGS, PROFILES, AND FINISHES. 08100-9 SUBMIT MANUFACTURER'S CERTIFICATION FOR EACH CUSTOM STEEL FIRE -RATED DOOR FRAME WHICH IS LARGER THAN THE SIZE LIMITATIONS ESTABLISHED BY NFPA AND UL FOR LABELING. STATE THAT THE UNIT HAS BEEN CONSTRUCTED IN ACCORDANCE WITH ALL THE APPLICABLE REQUIREMENTS FOR LABELED CONSTRUCTION. 08100-10 SUBMIT SHOP DRAWINGS SHOWING FABRICATION AND INSTALLATION OF STANDARD METAL FRAMES. INCLUDE DETAILS OF EACH FRAME TYPE, ELEVATIONS OF EACH DOOR DESIGN TYPE, CONDITIONS AT OPENINGS, DETAILS OF CONSTRUCTION, LOCATION, AND INSTALLATION REQUIREMENTS OF DOOR AND FRAME HARDWARE AND REFORCEMENTS, AND DETAILS OF JOINTS AND CONNECTIONS. SHOW ANCHORAGE AND ACCESSORY ITEMS. 08100-11 SUBMIT SCHEDULE OF DOORS AND FRAMES USING SAME REFERENCE NUMBERS FOR DETAILS OPENINGS AS THOSE ON CONTRACT DRAWINGS. 08100-12 FRAMES SHALL BE DELIVERED CARDBOARD -WRAPPED OR CRATED TO PROVIDE PROTECTION DURING TRANSIT AND JOB STORAGE, PROVIDE ADDITIONAL PROTECTION TO PREVENT DAMAGE TO FINISH OF FACTORY -FINISHED FRAMES. 08100-13 FMES SHALL BE INSPECTED PROVIDED REFINISHED ITEMS RESO PECTS TO NEW WORK AND ACCEPTABLE TO ARCHITECT. REPAIREDR DAMAGE. MINOR DAMAGES MAY BE RCHI ECT. OTHERWISE, REMOVE AND REPLACEDAMAGED ITEMS AS DIREC EDARE EQUAL IN ALL 08100-14 FRAMES SHALL BE STORED AT BUILDING SITE UNDER COVER. PLACE UNITS ON MINIMUM FOUR INCH (411) HIGH WOOD BLOCKING. AVOID USE OF NON -VENTED PLASTIC OR CANVAS SHELTERS WHICH COULD CREATE HUMIDITY CHAMBERS. IF CARDBOARD WRAPPERS ON FRAMES BECOME WET, REMOVE CARTON/CARDBOARD IMMEDIATELY. PROVIDE 1/4" SPACES BETWEEN STACKED FRAMES TO PROMOTE AIR CIRCULATION. 08100-15 FABRICATE HOLLOW METAL UNITS TO BE RIGID, NEAT IN APPEARANCE, AND FREE FROM DEFECTS, WARP, OR BUCKLE. ACCURATELY FORM METAL TO REQUIRED SIZES AND PROFILES. WHEREVER PRACTICAL, FIT AND ASSEMBLE UNITS IN THE MANUFACTURER'S PLANT. CLEARLY IDENTIFY WORK THAT CANNOT BE PERMANENTLY FACTORY -ASSEMBLED BEFORE SHIPMENT TO ASSURE PROPER ASSEMBLY AT PROJECT SITE. 08100-16 EXPOSED JOINTS SHALL BE WELDED CONTINUOUSLY; GRIND, DRESS, AND MAKE SMOOTH, FLUSH, AND INVISIBLE. METALLIC FILLER TO CONCEAL MANUFACTURING DEFECTS IS NOT ACCEPTABLE. 08100-17 EXPOSED CONNECTIONS WITH HAIRLINE JOINTS SHALL BE ACCURATELY MACHINED, FILED, AND FITTED, UNLESS OTHERWISE NOTED. 08100-18 CONCEAL ALL FASTENINGS, UNLESS OTHERWISE NOTED. COUNTERSINK EXPOSED SCREWS USING FLAT PHILLIPS HEAD SCREWS. 08100-19 FRAMES SHALL BE PREPARED IN ACCORDANCE WITH FINAL DOOR HARDWARE SCHEDULE AND TEMPLATES PROVIDED BY HARDWARE SUPPLIER INSTALLER SHALL COMPLY WITH APPLICABLE REQUIREMENTS OF ANSI A115 SERIES SPECIFICATIONS FOR DOOR AND FRAME PREPARATION FOR HARDWARE. 08100-20 PREPARE HOLLOW METAL UNITS TO RECEIVE MORTISED AND CONCEALED FINISH HARDWARE, INCLUDING CUTOUTS, REINFORCING, DRILLING, AND TAPPING IN ACCORDANCE WITH FINAL FINISH HARDWARE SCHEDULE AND TEMPLATES PROVIDED BY HARDWARE SUPPLIER. 08100-21 REINFORCE HOLLOW METAL UNITS TO RECEIVE SURFACE -APPLIED HARDWARE. DRILLING OR TAPPING FOR SURFACE -APPLIED FINISH HARDWARE MAY BE DONE AT PROJECT SITE. THROUGH BOLTING WILL NOT BE PERMITTED. 08100-22 INSTALLER SHALL EXAMINE THE SUBSTRATE AND CONDITIONS UNDER WHICH HOLLOW METAL WORK IS TO BE INSTALLED. NOTIFY THE CONTRACTOR, IN WRITING, OF ANY CONDITIONS DETRIMENTAL TO PROPER AND TIMELY COMPLETION OF WORK. 08100-23 INSTALLER SHALL COMPLY WITH PROVISIONS OF SI-105 "RECOMMENDED ERECTION INSTRUCTIONS FOR STEEL FRAMES," UNLESS OTHERWISE NOTED. 08100-24 FIRE -RATED FRAMES SHALL BE INSTALLED IN ACCORDANCE WITH NFPA STANDARD NO. 80. 08100-25 EXCEPT ON WEATHER-STRIPPED FRAMES, DRILL STOPS SHALL BE DRILLED TO RECEIVE 3 SILENCERS ON STRIKE JAMBS OF SINGLE -DOOR FRAMES AND 2 SILENCERS ON HEADS OF DOUBLE -DOOR FRAMES. 08100-26 IN METAL STUD PARTITIONS, INSTALL AT LEAST THREE (3) WALL ANCHORS PER JAMB AT HINGE AND STRIKE LEVELS. IN CLOSED STEEL STUD PARTITIONS, ATTACH WALL ANCHORS TO STUDS WITH SCREWS. 08100-27 IMMEDIATELY AFTER ERECTION OF FRAMES, SAND SMOOTH ANY RUSTED OR DAMAGED AREAS OF PRIME COAT AND APPLY TOUCHUP OF COMPATIBLE AIR -DRYING PRIMER, 08100-28 CHECK AND READJUST OPERATING FINISH HARDWARE ITEMS IN HOLLOW METAL WORK JUST PRIOR TO FINAL INSPECTION. LEAVE WORK IN COMPLETE AND PROPER OPERATING CONDITION. REMOVE AND REPLACE DEFECTIVE WORK, INCLUDING FRAMES WHICH ARE WARPED, BOWED OR OTHERWISE UNACCEPTABLE. CTION 08200 WOOD DOORS 08200-1 QUALITY SHALL COMPLY WITH THE FOLLOWING STANDARDS: 08200-2 "INDUSTRY STANDARD (I.S.) FOR WOOD FLUSH DOORS," OF THE NATIONAL WOOD WINDOW AND DOOR ASSOCIATION (NWWDA) 08200-3 "ARCHITECTURAL WOODWORK QUALITY STANDARDS" AND SECTION 1300 "ARCHITECTURAL FLUSH DOORS," OF THE ARCHITECTURAL WOODWORK INSTITUTE (AWI) FOR GRADE OF DOOR, CORE CONSTRUCTION, FINISH AND OTHER REQUIREMENTS EXCEEDING THOSE OF THE NWMA STANDARD. 08200-4 DOORS SHALL COMPLY WITH REFERENCE AWI QUALITY STANDARD INCLUDING SECTION 1500, "FACTORY FINISHING." WOOD VENEERED DOORS WITH TRANSPARENT FINISH SHALL BE PREFINISHED AT FACTORY. TRANSPARENT FINISH SHALL COMPLY WITH REQUIREMENTS INDICATED FOR GRADE, FINISH SYSTEM, STAINING EFFECT AND SHEEN: A. AWI GRADE: PREMIUM B. SPECIES: AS LISTED IN FINISH SCHEDULE C. VENEER LEAF MATCHING: (BALANCED or CENTER BALANCED) AND (BOOK or SLIP or RANDOM) MATCHED_ D. STAIN: MATCH ARCHITECT'S SAMPLE E. EFFECT: FILLED FINISH F. SHEEN: 40% OR AS DETERMINED BY APPROVED SAMPLE. 08200-5 ALL WOOD DOORS SHALL BE MANUFACTURED TWO INCHES (7) LONGER THAN SHOWN ON DRAWINGS AND/OR SCHEDULES. BOTTOM OF DOOR ONLY WILL BE TRIMMED TO EACH OPENING FOR REQUIRED CLEARANCE. 08200-6 FIRE -RATED DOORS SHALL BE INSTALLED IN CORRESPONDING FIRE -RATED FRAMES IN ACCORDANCE WITH REQUIREMENTS OF NFPA NO. 80. PROVIDE UL LABEL ON EACH FIRE- RATED DOOR. 08200-7 FIRE RATED WOOD DOORS SHALL BE IDENTICAL IN MATERIALS AND CONSTRUCTION TO UNITS TESTED IN DOOR AND FRAME ASSEMBLIES PER ASTM E152 AND WHICH ARE LABELED AND LISTED FOR RATINGS INDICATED BY UL, WARNOCK HERSEY OR OTHER TESTING AND INSPECTION AGENCY ACCEPTABLE TO AUTHORITIES HAVING JURISDICTION. 08200-8 PROVIDE PRODUCTS OF ONE OF THE FOLLOWING MANUFACTURES, SUBJECT TO COMPLIANCE WITH REQUIREMENTS FOR SOLID CORE DOORS WITH VENEER FACES: A. ALGOMA HARDWOODS, INC. B. EGGERS INDUSTRIES, ARCHITECTURAL DOOR DIVISION C. IPIK DOOR COMPANY, INC. D. MARSHFIELD 08200-9 SEE PAINT SPECIFICATIONS FOR FINISH REQUIREMENTS FOR OPAQUE AND TRANSPARENT FINISHES. 08200-10 FACES AND EDGES OF DOORS SHALL BE SHOP -SEALED FOR TRANSPARENT FINISH WITH STAIN AND OTHER REQUIRED PRE -TREATMENTS AND FIRST COAT OF FINISH. 08200-11 SUBMIT DOOR MANUFACTURER'S TECHNICAL DATA FOR EACH TYPE OF DOOR, INCLUDING DETAILS OF CORE AND EDGE CONSTRUCTION AND FACTORY FINISHING SPECIFICATIONS. 08200-12 SUBMIT SHOP DRAWINGS INDICATING LOCATION AND SIZE OF EACH DOOR, ELEVATION OF EACH TYPE OF DOOR, DETAILS OF CONSTRUCTION, LOCATION AND EXTENT OF HARDWARE BLOCKING, FIRE RATINGS, REQUIREMENTS FOR FACTORY FINISHING, AND OTHER PERTINENT DATA. 08200-13 SUBMIT WRITTEN WARRANTY AGREEMENT IN DOOR MANUFACTURER'S STANDARD FORM, SIGNED BY MANUFACTURER, INSTALLER, AND CONTRACTOR, AGREEING TO REPAIR OR REPLACE DEFECTIVE DOORS THAT HAVE WARPED (BOW, CUP OR TWIST) OR THAT SHOW PHOTOGRAPHING OF CORE CONSTRUCTION BELOW FACE, DO NOT CONFORM TO TOLERANCE LIMITATIONS OF NWWDA OR DELAMINATE. THE WARRANTY SHALL BE IN EFFECT FOR LIFETIME OF INSTALLATION AND SHALL COMMENCE UPON SUBSTANTIAL COMPLETION. 08200-14 OFFSET TOLERANCE AT MEETING EDGE OF PAIR OF DOORS SHALL NOT EXCEED 1/8" EVEN IF SINGLE DOORS COMPLY WITH WARP TOLERANCE. 08200-16 WARRANTY SHALL INCLUDE REINSTALLATION WHICH MAY BE REQUIRED DUE TO REPAIR OR REPLACEMENT OF DEFECTIVE DOORS WHERE DEFECT WAS NOT APPARENT PRIOR TO HANGING. 08200-16 WOOD DOORS SHALL BE PROTECTED DURING TRANSIT, STORAGE, AND HANDLING TO PREVENT DAMAGE, SOILING, AND DETERIORATION. COMPLY WITH THE "ON -SITE CARE" RECOMMENDATIONS OF NWWDA PAMPHLET, "CARE AND FINISHING OF WOOD DOORS," AND WITH MANUFACTURER'S INSTRUCTIONS. 08200-17 WOOD DOORS SHALL BE CARTON AND/OR CRATED TO PROVIDE PROTECTION DURING TRANSIT AND JOB STORAGE. COMPLY WITH MANUFACTURER'S INSTRUCTIONS FOR PRECAUTIONS REQUIRED FOR FIRE -RATED DOORS TO PREVENT MOISTURE DETERIORATION OF FIRE -RETARDANT SALTS. 08200-18 DOORS AND PANELS SHALL RE PRE FIT IN ACCORDANCE WITH TOLERANCE REQUIREMENTS OF NWWDA INDUSTRY STANDARD I.S. 1. PROVIDE STANDARD BEVEL OR RADIUS TO EDGES OF DOORS AS REQUIRED BY THE INSTALLATION. 08200-19 IDENTIFY EACH DOOR WITH INDIVIDUAL OPENING NUMBERS WHICH CORRELATE WITH DESIGNATION SYSTEM USED ON SHOP DRAWINGS FOR DOORS, FRAMES, AND HARDWARE, USING TEMPORARY, REMOVABLE OR CONCEALED MARKINGS. 08200-20 DO NOT DELIVER OR INSTALL DOORS UNTIL CONDITIONS FOR TEMPERATURE AND RELATIVE HUMIDITY HAVE BEEN STABILIZED AND WILL BE MAINTAINED IN STORAGE AND INSTALLATION AREAS DURING THE REMAINDER OF CONSTRUCTION PERIOD TO COMPLY WITH THE AWI QUALITY STANDARD SECTION 100-S-3 "MOISTURE CONTENT," APPLICABLE TO THE PROJECT'S GEOGRAPHICAL LOCATION. CONDITION DOORS TO AVERAGE PREVAILING HUMIDITY IN INSTALLATION AREA PRIOR TO HANGING. 08200-21 CONTRACTOR SHALL EXAMINE ALL INSTALLED DOOR FRAMES PRIOR TO HANGING DOOR. VERIFY THAT FRAMES COMPLY WITH INDICATED REQUIREMENTS FOR THE SIZE, TYPE, LOCATION, AND SWING CHARACTERISTICS AND HAVE BEEN INSTALLED WITH PLUMB JAMBS AND LEVEL HEADS. REJECT DOORS WITH DEFECTS. 08200-22 COORDINATE MEASUREMENTS OF HARDWARE MORTISES IN METAL FRAMES TO VERIFY DIMENSIONS AND ALIGNMENT BEFORE PROCEEDING WITH FACTORY PREMACHINING. 08200-23 INSTALLATION OF WOOD DOORS SHALL COMPLY WITH MANUFACTURER'S INSTRUCTIONS, WITH REFERENCED INDUSTRY STANDARDS, AND AS INDICATED ON CONTRACT DRAWINGS. THE MOST STRINGENT REQUIREMENTS SHALL APPLY. 08200-24 DOORS SHALL BE ALIGNED AND FIT IN FRAMES WITH UNIFORM CLEARANCES AND BEVELS AS INDICATED. DO NOT TRIM STILES AND RAILS IN EXCESS OF LIMITS SET BY MANUFACTURER OR PERMITTED WITH FIRE -RATED DOORS. SEAL CUT SURFACES AFTER FITTING AND MACHINING. 08200-25 REHANG OR REPLACE DOORS WHICH DO NOT SWING OR OPERATE FREELY AND REFINISH OR REPLACE ALL DOORS DAMAGED DURING INSTALLATION. 08200-26 REPLACE OR REFINISH DOORS WHERE CONTRACTOR'S WORK CONTRIBUTED TO REJECTION OR TO VOIDING OF MANUFACTURER'S WARRANTY. 08200-27 INSTALLER SHALL ADVISE THE CONTRACTOR OF PROPER PROCEDURES REQUIRED FOR PROTECTION OF INSTALLED WOOD DOORS FROM DAMAGE OR DETERIORATION UNTIL TIME OF SUBSTANTIAL PROJECT COMPLETION. ECTION 08700 FINI -1 HARDWARE 08700-1 FINISH HARDWARE SHALL BE PROVIDED FOR ALL DOORS INCLUDING ALL ITEMS KNOWN COMMERCIALLY AS BUILDERS HARDWARE OR FINISH HARDWARE. INCLUDE LOCK CYLINDERS FOR LOCKS FURNISHED IN OTHER SECTIONS WHERE SO SPECIFIED. 08700-2 ALL FINISH HARDWARE SHALL COMPLY WITH CURRENT ACCESSIBILITY AND ADA CODES. ALL LOCKS AND LATCHES SHALL BE LEVER TYPE. PROVIDE LOCKS WITH KNURLED LEVERS ON ENTRY SIDE TO DOORS WHICH ARE POTENTIALLY DANGEROUS TO BLIND OR VISUALLY HANDICAPPED PERSONS. 08700-3 HARDWARE FOR FIRE -RATED OPENINGS SHALL COMPLY WITH NFPA NO. 80 AND LOCAL BUILDING CODE REQUIREMENTS. PROVIDE ONLY HARDWARE WHICH HAS BEEN TESTED AND LISTED BY UL OR FM FOR TYPES AND SIZES OF DOORS REQUIRED AND COMPLIES WITH REQUIREMENTS OF DOOR AND DOOR FRAME LABELS. 08700-4 NO NAMES, DESIGNS, OR LABELS SHALL BE PERMITTED ON THE FOLLOWING ITEMS: FACE OF CYLINDERS, TURN PIECES OR OPERATING TRIM OF LOCK SETS OR LATCH SETS, CASE COVERS OF SURFACE APPLIED CLOSING DEVICES, AND UNDERSIDE OF DOOR HOLDER ARMS. 08700-5 THE DRAWINGS SHOW THE SWING OR TRAVEL OF EACH DOOR LEAF (LEFT, RIGHT, REVERSE BEVEL, SLIDE, ETC.). FURNISH EACH ITEM OF HARDWARE FOR PROPER INSTALLATION AND OPERATION OF THE DOOR TRAVEL AS SHOWN. 08700-6 ACCEPTABLE MANUFACTURERS: A. HINGES, BUTTS, PIVOTS: STANLEY, McKINNEY, HAGER, LAWRENCE, RIXON B. LOCK/LEVER SETS: SCHLAGE "L" SERIES C. CLOSER: CORBIN/RUSSWIN DC2200/DC2100, LCN 4040, HAGER D. DOOR TRIM: QUALITY, ROCKWOOD, HAGER E. DOOR STOPS: HAGER, IVES, MODRICK, QUALITY, ROCKWOOD F. DOOR HOLDERS: HAGER, CHECKMATE, ABH, IVES, ROCKWOOD G. THRESHOLDS AND WEATHER-STRIP: PEMKO, REESE, ZERO, NATIONAL GUARD H. STRIKE: IVES 08700-7 WHERE SEVERAL MANUFACTURERS ARE SPECIFIED FOR ONE TYPE OF HARDWARE, USE ONLY THE PRODUCTS OF ONE MANUFACTURER. 08700-8 FASTENINGS FOR INSTALLATION SHALL BE FURNISHED WITH EACH HARDWARE ITEM. PROVIDE PHILLIPS FLATHEAD COUNTERSUNK SCREWS UNLESS OTHERWISE NOTED. ANY EXPOSED (EXPOSED UNDER ANY CONDITION) SCREWS SHALL MATCH HARDWARE FINISH OR, IF EXPOSED IN SURFACES OF OTHER WORK, SHALL MATCH FINISH OF SUCH OTHER WORK AS CLOSELY AS POSSIBLE. PROVIDE HEX BOLTS AND BARRELS FOR ALL DOOR CLOSURES, EXIT DEVICES, AND DOOR HOLDERS ON METAL DOORS AND FIRE -RATED WOOD DOORS. 08700-9 CONCEALED FASTENERS SHALL BE PROVIDED FOR HARDWARE UNITS WHICH ARE EXPOSED WHEN DOOR IS CLOSED, EXCEPT TO THE EXTENT NO STANDARD UNITS OF THE TYPE SPECIFIED ARE AVAILABLE WITH CONCEALED FASTENERS. DO NOT USE THRU-BOLTS FOR INSTALLATION WHERE BOLT HEAD OR NUT ON OPPOSITE FACE IS EXPOSED IN OTHER WORK, EXCEPT WHERE IT IS NOT FEASIBLE TO ADEQUATELY REINFORCE THE WORK IN SUCH CASES, SLEEVES SHALL BE PROVIDED FOR EACH THRU-BOLT OR USE HEX SCREW FASTENERS. 08700-10 ALL CLOSURES SHALL BE FULLY ADJUSTABLE TYPE WITH COMPLETE SPRING POWER ADJUSTMENT, FIELD ADJUSTABLE ACCORDING TO DOOR SIZE AND FREQUENCY OF USE. ALLOW FULL 1800 OPENING OF DOORS UNLESS RESTRICTED BY WALLS. FURNISH FLUSH MOUNT TRANSOM BRACKETS WHERE NO TRANSOM BAR EXISTS. WHERE CLOSURES ARE INDICATED TO BE DELAYED ACTION, PROVIDE UNITS DESIGNED WITH AN ADJUSTABLE DELAY THAT HOLDS THE DOOR OPEN BEFORE THE CLOSING CYCLE BEGINS. 08700-11 ALL CLOSURES ON DOORS ACCESSIBLE TO THE PHYSICALLY HANDICAPPED SHALL COMPLY WITH STATE AND FEDERAL (ADA) STANDARDS FOR DOOR OPENING FORCE AND DELAYED ACTION CLOSING. 08700-12 CLOSURES SHALL BE SIZED ON JOBSITE BY INSTALLATION CREW. SIZE IS TO BE IN STRICT ACCORDANCE WITH ADA, ANSI A117.1, AND MANUFACTURER'S INSTRUCTIONS. 08700-13 WHETHER SPECIFIED IN HARDWARE SETS OR NOT, ALL FIRE -RATED DOORS SHALL RECEIVE A CLOSER. 08700-14 PROVIDE PARALLEL ARMS FOR ALL OVERHEAD CLOSURES, UNLESS OTHERWISE NOTED, 08700-15 EXCEPT FIRE -RATED DOORS, EXIT DEVICES SHALL BE EQUIPPED WITH KEYED DOGGING DEVICE TO HOLD THE PUSH BAR DOWN AND THE LATCH BOLT IN A RETRACTED POSITION. WHEN FUNCTION OF EXIT DEVICE REQUIRES CYLINDER, PROVIDE TYPE OF CYLINDER (RIM OR MORTISE) REQUIRED AND KEYED AS PER INSTRUCTIONS. LEVER DESIGN SHALL MATCH LOCKS. 08700-16 WHERE EXIT DEVICES ARE REQUIRED ON FIRE -RATED LABEL DOORS, DEVICES SHALL BE PROVIDED WITH UL LABEL INDICATING "FIRE EXIT HARDWARE." FOR DOORS WITHOUT FIRE RATING, PROVIDE DEVICES LISTED FOR "PANIC HARDWARE." WHETHER SPECIFIED IN HARDWARE SETS OR NOT, ALL FIRE EXIT DEVICES SHALL CARRY A UL FIRE RATED LABEL AT FIRE DOORS AND BE IN COMPLIANCE WITH NFPA STANDARD NO. 80. 08700-17 MATCHING FINISHES SHALL BE PROVIDED FOR HARDWARE UNITS AT EACH DOOR OR OPENING TO THE GREATEST EXTENT POSSIBLE. REDUCE DIFFERENCES IN COLOR AS MUCH AS COMMERCIALLY POSSIBLE WHERE THE TEXTURES OF BASE METAL OR METAL FORMING PROCESS IS DIFFERENT FOR INDIVIDUAL UNITS OF HARDWARE EXPOSED AT THE SAME DOOR OR OPENING. IN GENERAL, MATCH ITEMS TO THE MANUFACTURER'S STANDARD FINISH FOR THE LATCH AND LOCKSET (OR PUSH-PULL UNITS) FOR COLOR AND TEXTURE. REDUCE VARIANCE IN HUE IN THE COLOR OF EACH FINISH. TYPE OF FINISH FOR EACH HARDWARE PART IS INDICATED IN THE HARDWARE SCHEDULE. 08700-18 PROVIDE NUMBER OF HINGES INDICATED, BUT NOT LESS THAN THREE (3) HINGES PER DOOR LEAF FOR DOORS 90" OR LESS IN HEIGHT AND ONE ADDITIONAL HINGE FOR EACH 30" OF ADDITIONAL HEIGHT OR SHOWN ON SCHEDULE. ALL DOORS WITH CLOSURES SHALL HAVE BEARING HINGES. 08700-19 HINGE PINS SHALL BE PROVIDED AS FOLLOWS, UNLESS OTHERWISE INDICATED: I. STEEL HINGES: STEEL PINS J. NONFERROUS HINGES: STAINLESS STEEL PINS K. OUT -SWING CORRIDOR DOORS: NON-REMOVEABLE PINS L. INTERIOR DOORS: NON -RISING PINS 1240 East 5th Avenue Tampa, FL 33605 T 813.223.2293 F 813.223.2433 www.asdsky.com 4- S UF�TERR A Apt\ WELLNESS W 00.0.0 W N LO rn co J f4 LL 3 t � U J U) T 1J oa This drawing is the property of Associatf Space Design, Inc. and is not to be reproduced or copied in whole or part. It not to be used on any other project and is be returned upon request. Scales as stat, herein are for reference only as normal reproduction processes may alter the accuracy of original drawings. Associated Space Design, Inc. 2018 N0: DATE, REMARKS: REVISIONS', rTITLE:ICATIONS 51394.64 ISSUE DATE. 05-23-18 DRAWN BY: AC CHECKED BY: KN SHEET NUMBER: AOA 2 SECTION 08700 FINISH HARDWARE CANT. 08700-20 MANUAL OR AUTOMATIC FLUSH BOLT COORDINATORS AND MOUNTING BRACKETS SHALL BE PROVIDED WHERE LISTED IN HARDWARE SETS. THEY SHALL BE THE PRODUCT OF ONE MANUFACTURER. ALL BOLTS FOR FIRE -RATED DOORS SHALL HAVE UL LABEL. PROVIDE MINIMUM 1/2" DIAMETER RODS OF BRASS, BRONZE, OR STAINLESS STEEL, WITH MINIMUM 3/4" THROW. PROVIDE DUST PROOF STRIKE AT ALL LOCATIONS EXCEPT WHERE THRESHOLDS ARE SHOWN. 08700.21 ALL FINISH HARDWARE TO BE INSTALLED ON OR IN METAL DOORS AND/OR FRAMES SHALL BE MANUFACTURED TO TEMPLATE. TEMPLATE MACHINE SCREWS SHALL BE FURNISHED FOR ALL SUCH MATERIALS. THIS SUPPLIER SHALL FURNISH HARDWARE SCHEDULE AS APPROVED BY THE ARCHITECT AND ALL NECESSARY TEMPLATE TRANSMITTALS TO METAL FRAME FABRICATORS OR OTHER SUPPLIERS REQUIRING SAME, FOR THEIR COORDINATION AND USE. UPON REQUEST, CHECK SHOP DRAWINGS OF SUCH OTHER WORK TO CONFIRM THAT ADEQUATE PROVISIONS ARE MADE FOR PROPER LOCATION AND INSTALLATION OF HARDWARE. 08700-22 SUBMIT MANUFACTURER'S TECHNICAL PRODUCT DATA FOR EACH ITEM OF HARDWARE. INCLUDE WHATEVER INFORMATION MAY BE NECESSARY TO SHOW COMPLIANCE WITH REQUIREMENTS AND INCLUDE INSTRUCTIONS FOR INSTALLATION AND FOR MAINTENANCE OF OPERATING PARTS AND FINISHES. 08700.23 SUBMIT FINAL HARDWARE SCHEDULE IN MANNER INDICATED BELOW. COORDINATE HARD- WARE WITH DOORS, FRAMES, AND RELATED WORK TO ENSURE PROPER SIZE, THICKNESS, HAND, FUNCTION, AND FINISH OF HARDWARE. ORGANIZE HARDWARE SCHEDULE INTO "HARDWARE SETS" INDICATING COMPLETE DESIGNATIONS OF EVERY ITEM REQUIRED FOR EACH DOOR OR OPENING. INCLUDE THE FOLLOWING INFORMATION: M. TYPE, STYLE, FUNCTION, SIZE, AND FINISH OF EACH HARDWARE ITEM N. NAME AND MANUFACTURER OF EACH ITEM 0. FASTENINGS AND OTHER PERTINENT INFORMATION P. LOCATION OF HARDWARE SET CROSS-REFERENCED WITH DRAWINGS AND SCHEDULE Q. EXPLANATION OF ALL ABBREVIATIONS, SYMBOLS, CODES, ETC CONTAINED ON SCHEDULE R. MOUNTING LOCATIONS FOR HARDWARE S. KEYING INFORMATION T. DOOR AND FRAME SIZES AND MATERIALS. 08700-24 KEYING SYSTEM SHALL BE REVIEWED WITH OWNER AND BASE BUILDING OWNER, AND PROVIDE THE TYPE REQUIRED (MASTER, GRAND MASTER, OR GREAT -GRANDMASTER), EITHER NEW OR INTEGRATED WITH BASE BUILDING OWNER'S EXISTING SYSTEM. 08700-26 HARDWARE UNITS SHALL BE MOUNTED AT HEIGHTS INDICATED IN "RECOMMENDED LOCATIONS FOR BUILDERS HARDWARE FOR STANDARD STEEL DOORS AND FRAMES" BY THE DOOR AND HARDWARE INSTITUTE, EXCEPT AS SPECIFICALLY INDICATED OR AS REQUIRED TO COMPLY WITH GOVERNING REGULATIONS AND EXCEPT AS MAY BE DIRECTED BY ARCHITECT ON DRAWINGS UNDER THE DOOR DETAILS AND TYPICAL MOUNTING HEIGHT DETAIL. 08700-26 EACH HARDWARE ITEM SHALL BE INSTALLED IN COMPLIANCE WITH THE MANUFACTURER'S INSTRUCTIONS AND RECOMMENDATIONS. WHEREVER CUTTING AND FITTING IS REQUIRED TO INSTALL HARDWARE ONTO OR INTO SURFACES WHICH ARE LATER TO BE PAINTED OR FINISHED IN ANOTHER WAY, COORDINATE REMOVAL, STORAGE AND REINSTALLATION OR APPLICATION OF SURFACE PROTECTIONS WITH FINISHING WORK SPECIFIED IN PAINTING SPECIFICATIONS. SURFACE -MOUNTED ITEMS SHALL NOT BE INSTALLED UNTIL FINISHES HAVE BEEN COMPLETED ON THE SUBSTRATE. 08700-27 SET UNITS LEVEL, PLUMB, AND TRUE TO LINE AND LOCATION. ADJUST AND REINFORCE THE ATTACHMENT SUBSTRATE AS NECESSARY FOR PROPER INSTALLATION AND OPERATION. 08700-28 ADJUST AND CHECK EACH OPERATING ITEM OF HARDWARE AND EACH DOOR TO ENSURE PROPER OPERATION AND FUNCTION OF EVERY UNIT. REPLACE UNITS WHICH CANNOT BE ADJUSTED TO OPERATE FREELY AND SMOOTHLY AS INTENDED FOR THE APPLICATION MADE. SECTION 09050 GENERAL FINISH NOTES 09060-1 SELECTED MATERIALS ARE SHOWN BY ALLOWANCES. ALLOWANCES SHALL BE FOR VARIATIONS IN MATERIALS ONLY. ALL INSTALLATION AND RELATED PRODUCTS TO ACCOMPLISH THE COMPLETE ASSEMBLY SHALL BE INCLUDED IN THE CONTRACT PRICING BY THE CONTRACTOR. 09060-2 RETURN UNUSED, UNOPENED MATERIALS TO THE MANUFACTURER OR SUPPLIER FOR CREDIT TO THE OWNER AFTER INSTALLATION HAS BEEN COMPLETED AND ACCEPTED. UNUSED MATERIALS FROM OPEN PACKAGES ARE TO BE TURNED OVER TO THE OWNER AS ATTIC STOCK. SEE SPECIFIC MATERIAL SPECIFICATION SECTIONS FOR ADDITIONAL ATTIC STOCK MATERIAL REQUIREMENTS. 09050-3 COMPLY WITH THE MANUFACTURER'S RECOMMENDATIONS AND INSTRUCTIONS FOR INSTALLATION FOR ALL PRODUCTS AND MATERIALS USED IN THE PROJECT TO THE EXTENT THAT THOSE INSTRUCTIONS ARE MORE EXPLICIT AND/OR MORE STRINGENT THAN THE REQUIREMENTS IN THE CONTRACT DOCUMENTS. 09050-4 INSPECT MATERIALS OR EQUIPMENT IMMEDIATELY UPON DELIVERY AND AGAIN PRIOR TO INSTALLATION. REJECT DAMAGED AND/OR DEFECTIVE ITEMS. PROTECT ALL MATERIALS FROM DAMAGE AND MOISTUIRE DURING DELIVERY, INSTALLATION, AND USE. 09050-5 PROVIDE APPROPRIATE ATTACHMENT AND CONNECTION DEVICES AND METHODS NECESSARY FOR SECURING THE WORK. SECURE ALL WORK TRUE TO LINE AND LEVEL, ALLOW FOR BUILDING EXPANSION AND BUILDING MOVEMENT. 09050-6 PROVIDE UNIFORM JOINT WIDTHS IN EXPOSED WORK. ARRANGE JOINTS IN EXPOSED WORK TO OBTAIN THE BEST VISUAL EFFECT. 09050-7 RECHECK MEASUREMENTS AND DIMENSIONS BEFORE STARTING EACH INSTALLATION. 09060-8 THE CONTRACTOR SHALL ENSURE THAT NO PART OF THE CONSTRUCTION, COMPLETED OR IN PROGRESS, IS SUBJECT TO HARMFUL, DANGEROUS, OR DAMAGING EXPOSURE DURING THE CONSTRUCTION PERIOD. SUCH EXPOSURE INCLUDES BUT IS NOT LIMITED TO THE FOLLOWING: EXCESSIVE HIGH OR LOW TEMPERATURES, EXCESSIVE HIGH OR LOW HUMIDITY, WATER, ABRASION, LIGHT, STAINING; UNPROTECTED STORAGE, THEFT, FIRE, OR VANDALISM. 09050-9 SUBMIT FULL SIZE AND FULLY FABRICATED SAMPLES, CURED AND FINISHED AS SPECIFIED WITH THE MATERIAL OR PRODUCT SPECIFIED. SAMPLES INCLUDE PARTIAL SECTIONS OR MANUFACTURED OR FABRICATED COMPONENTS, CUTS OF MATERIALS, COLOR RANGE SETS AND SWATCHES SHOWING COLOR TEXTURE AND PATTERN. 09050-10 WHERE VARIATION IN COLOR PATTERN AND TEXTURE OR OTHER CHARACTERISTICS ARE INHERENT IN THE MATERIAL, SUBMIT MULTIPLE UNITS (NOT LESS THAN 3) TO EXHIBIT THE FULL RANGE OF VARIATION. 09050-11 PROVIDE ALL MANUFACTURER'S STANDARD WARRANTIES FOR THE VARIOUS SPECIFIED MATERIALS TO THE OWNER. IF WORK COVERED BY A WARRANTY HAS FAILED AND BEEN CORRECTED BY REPLACEMENT, REINSTATE THE WARRANTY BY WRITTEN ENDORSEMENT. THE REINSTATED WARRANTY SHALL BE EQUAL TO THE ORIGINAL WARRANTY WITH AN EQUITABLE ADJUSTMENT FOR DEPRECIATION. 09050-12 THE CONTRACTOR SHALL PROVIDE A ONE YEAR WARRANTY FROM DATE OF SUBSTANTIAL COMPLETION COVERING DEFECTS ARISING FROM BOTH MATERIALS AND WORKMANSHIP FOR WORK PERFORMED BY THE CONTRACTOR AND HIS SUBCONTRACTORS, 09050-13 ALL EXPOSED SURFACES SHALL BE FINISHED. WHERE THE FINISH IS NOT INDICATED OR UNCLEAR, VERIFY THE FINISH WITH THE ARCHITECT. 09060-14 THE CONTRACTOR SHALL BE RESPONSIBLE FOR CONFIRMING THE DELIVERY DATE OF ALL FINISH MATERIALS AS APPLICABLE DURING THE BIDDING PERIOD AND SHALL SUBMIT THOSE DATES IN WRITING WITH HIS BID. 09050-15 VERIFY FINISHES WITH THE ARCHITECT IN THE FIELD PRIOR TO INSTALLATION, 09060-16 FINISH MATERIAL SUBSTRATE SHALL BE FREE OF IMPERFECTIONS AND MARKINGS SUBJECT TO BLEED -THROUGH, 09050-17 REPAIR, REFINISH AND PREPARE EXISTING SURFACES TO RECEIVE NEW OR EXISTING MATERIALS, AS APPLICABLE. THIS INCLUDES, BUT IS NOT LIMITED TO FLOORING, DOORS & FRAMES, BASE BUILDING PARTITIONS, FLOOR SLABS, CEILINGS, ETC. UNLESS NOTED OTHERWISE. SECTION 09200 GYPSUM WALL BOARD 09200-1 GYPSU M WALL BOARD AND STEEL FRAMING INSTALLATION, APPLICATION, AND FINISHING SHALL COMPLY WITH ASTM C754 AND ASTM C840 STANDARDS AND SF ALL BE IN ACCORDANCE WITH THE CURRENT VERSION OF UNITED STATES GYPSUM - GYPSUM CONSTRUCTION HANDBOOK. MATERIALS AND INSTALLATION SHALL COMPLY WITH APPLICABLE REQUIREMENTS OF GA- 216 "APPLICATION AND FINISHING OF GYPSUM BOARD" BY THE G PSUM ASSOCIATION, EXCEPT WHERE MORE DETAILED OR MORE STRINGENT REQUIREMENTS ARE INDICATED, INCLUDING THE RECOMMENDATIONS OF THE MANUFACTURER. WHER WORK IS INDICATED FOR FIRE-RESISTANT RATINGS, INCLUDING THOSE REQUIRED TO COMPLY WITH GOVERNING REGULATIONS, PROVIDE MATER LS AND INSTALLATIONS IDENTICAL WITH APPLICABLE ASSEMBLIES WHICH HAVE BEEN TESTED AND LISTED BY RECOGNIZED AUTHORITIES, INCLU ZING UL, GYPSUM ASSOCIATION, AIA AND OTHER TESTING AND/OR AGENCIES ACCEPTABLE TO AUTHORITIES HAVING JURISDICTION. ESTABII.ISH AND MAINTAIN ENVIRONMENTAL CONDITIONS FOR APPLICATION AND FINISHING GYPSUM BOARD TO COMPLY WITH ASTM C840 AND WITH GYPSUM BOARD MANUFACTURER'S RECOMMENDATIONS. STEEL STUDS AND JOISTS SHALL COMPLY WITH ASTM C645, WITH FLANGE EDGES OF STUDS BENT BACK 90- AND DOUBLED OVER TO FORM 3/16" MINIMUM LIP (RETURN) AND COMPLYING WITH THE FOLLOWING REQUIREMENTS FOR MINIMUM THICKNESS OF BASE (UNCOATED) METAL AND FOR DEPTH A. THICKNESS: 25-GAUGE AT STUDS AND INTERIOR CEILING JOISTS, U.O.N. B. STUD DEPTH: 2 112", 16" O.C., UNLESS OTHERWISE NOTED C. FRAMING: ALL FRAMING MEMBERS SHALL BE GALVANIZED FASTENERS SHALL BE PROVIDED OF TYPE, MATERIAL, SIZE, CORROSION RESISTANCE, HOLDING POWER, AND OTHER PROPERTIES REQUIRED TO FASTEN STEEL FRAMING AND FURRING MEMBERS SECURELY TO SUBSTRATES INVOLVED. FASTENERS SHALL COMPLY WITH RECOMMENDATIONS OF GYPSUM DRYWALL MANUFACTURERS FOR APPLICATIONS INDICATED. 09200- FOR F STENERS OF METAL FRAMING: PROVIDE SCREWS AS RECOMMENDED BY MANUFACTURER, TO FACILITATE FUTURE DISMANTLING, MINIMIZE USE OF NAI S. GYPSUM BOARD SHALL BE PROVIDED IN ACCORDANCE WITH ASTM C36 OF TYPES INDICATED IN MAXIMUM LENGTHS AVAILABLE TO MINIMIZE END -TO END J INTS. GYPSUM BOARD SHALL COMPLY WITH THE FOLLOWING REQUIREMENTS: D. THICKNESS: 5/8" THICK, UNLESS OTHERWISE NOTED E. TYPE: REGULAR OR TYPE X FOR FIRE -RESISTANCE -RATED ASSEMBLIES F. EDGES:TAPERED G. CONTENT: SYNTHETIC GYPSUM BOARD PANEL SIZES TO MINIMIZE WASTE. LAY OUT PANELS TO MINIMIZE WASTE AND REUSE CUTOFFS WHENEVER FEASIBLE. INSTALL MOISTURE -RESISTANT GYPSUM WALL BOARD PANELS IN AREAS EXPOSED TO MOISTURE AS REQUIRED. TRIM tCESSORIES, INCLUDING CORNER BEADS, EDGE TRIM, AND CONTROL JOINTS SHALL COMPLY WITH ASTM C1047 AND BE PROVIDED AS NECE ARY. MUD, BLEND AND SAND SMOOTH INTO ADJACENT SURFACES. CONTROL JOINTS CONSISTENT WITH LINES OF BUILDING SPACES AND AS INDICATED. CONTROL JOINTS SHALL NOT BE MORE THAN 30 FEET ON WALLS AND CEILINGS OVER 50' IN LENGTH. WALLEOARD JOINT TREATMENT MATERIALS SHALL BE PROVIDED AND COMPLY WITH ASTM C475, ASTM C840, AND RECOMMENDATIONS OF MANU ACTURERS OF BOTH GYPSUM BOARD AND JOINT TREATMENT MATERIALS FOR THE APPLICATION INDICATED: H. JOINT TAPE: PAPER. REINFORCING TAPE I. DRYING -TYPE JOINT COMPOUNDS: FACTORY -PREPACKAGED VINYL-ASED PRODUCTS ALL-PURPOSE COMPOUND FORMULATED FOR USE AS BOTH TAPING AND TOPPING COMPOUND J. AVOID PREMIXED JOINT COMPOUNDS CONTAINING ADDITIVES. PRODUCTS SHALL BE FREE OF ANTIFREEZE, VINYL ADHESIVES, PRESERVATIVES, BIOCIDES, AND OTHER SLOW -RELEASING COMPOUNDS. 4 RY MATERIALS FOR GYPSUM DRYWALL CONSTRUCTION SHALL COMPLY WITH REFERENCED STANDARDS AND THE RECOMMENDATIONS OF THE ACTURER OF THE GYPSUM BOARD. 09200- 5 PARTITIONS ARE DIMENSIONED FINISH FACE TO FINISH FACE UNLESS NOTED OTHERWISE. DIMENSIONS NOTED'CLEAR' (CUR) OR'HOLD' ARE NOT ADJUSTABLE WITHOUT THE APPROVAL OF THE ARCHITECT. 09200- 6 HEIGH 17S ARE DIMENSIONED FROM THE TOP OF FINISHED FLOOR, UNLESS NOTED OTHERWISE. 09200- 7 ALL P RTITIONS SHOWN ABUTTING INTO EXISTING WALLS SHALL ALIGN WITH FACE OF FINISHED SURFACES UNLESS NOTED OTHERWISE. 09200- 8 SUBMI MANUFACTURER'S PRODUCT SPECIFICATIONS FOR EACH TYPE OF GYPSUM BOARD, STEEL FRAME, AND TRIM ACCESSORY INDICATED. SUBSTRATE TO WHICH DRYWALL CONSTRUCTION ATTACHES OR ABUTS. PRESET HOLLOW METAL FRAMES, CAST -IN -ANCHORS, AND RAL FRAMING SHALL BE IN COMPLIANCE WITH REQUIREMENTS FOR INSTALLATION TOLERANCES AND OTHER CONDITIONS AFFECTING 1ANCE OF DRYWALL CONSTRUCTION. DO NOT PROCEED WITH INSTALLATION UNTIL UNSATISFACTORY CONDITIONS HAVE BEEN CORRECTED. MATERIALS INSIDE UNDER COVER AND KEEP THEM DRY AND PROTECTED AGAINST DAMAGE FROM WEATHER, DIRECT SUNLIGHT, SURFACE 01NATION, CORROSION, CONSTRUCTION TRAFFIC, AND OTHER CAUSES. GYPSUM BOARD SHALL BE STACKED NEATLY AND FLAT TO PREVENT 09200-21 HANDLE GYPSUM BOARDS TO PREVENT DAMAGE TO EDGES, ENDS, AND SURFACES. DO NOT BEND OR OTHERWISE DAMAGE METAL CORNER BEADS AND TRIM. 09200-22 MINIM M ROOM TEMPERATURE FOR NON -ADHESIVE ATTACHMENT OF GYPSUM BOARD SHALL NOT BE LESS THAN 40° F. MINIMUM ROOM TEMPERATURE FOR ADHESIVE ATTACHMENT AND FINISHING OF GYPSUM BOARD SHALL NOT BE LESS THAN 50° F FOR 48 HOURS PRIOR TO APPLI ATION AND CONTINUOUS THEREAFTER UNTIL DRYING IS COMPLETE. BUILDING SPACES SHALL BE VENTILATED TO REMOVE WATER NOT REQUIRED FOR DRYING JOINT TREATMENT MATERIALS. AVOID DRAFTS DURING DRY. HOT WEATHER TO PREVENT MATERIALS FROM DRYING TOO RAPIDLY. COOK INATE INSTALLATION OF CEILING SUSPENSION SYSTEM WITH INSTALLATION OF OVERHEAD STRUCTURAL SYSTEMS TO ENSURE THAT INSERTS AND HER STRUCTURAL ANCHORAGE PROVISIONS HAVE BEEN INSTALLED TO RECEIVE CEILING ANCHORS IN A MANNER THAT WILL DEVELOP THEIR FULL $$STRENGTH AND AT SPACING REQUIRED TO SUPPORT CEILING. VERIF PARTITION THICKNESS FOR INTERNAL INCLUSIONS SUCH AS PLUMBING, TOILET ACCESSORIES, PANEL BOXES, ETC. NOTIFY THE ARCHITECT IMME 'PARTITION OF ANY DISCREPANCIES BETWEEN THE SCHEDULED PARTITION AND ANY INTERNAL INCLUSIONS. FRAMING INSTALLATION SHALL COMPLY WITH ASTM C754 AND ASTM C840 REQUIREMENTS THAT APPLY TO FRAMING INSTALLATION. LIGHT GAGE COMPONENTS SHALL CONTAIN A MINIMUM OF 80% RECYCLED STEEL AS MANUFACTURED BY CLARKE STEEL. ALL P#RTITIONS SHALL BE INSTALLED PLUMB, TAPED, AND SANDED SMOOTH SO THAT THERE ARE NO VISIBLE JOINTS. SUPP EMENTARY FRAMING, BLOCKING, AND BRACING SHALL BE INSTALLED AT TERMINATION IN THE WORK AND FOR SUPPORT OF FIXTURES, EQUIPMENT SERVICES, HEAVY TRIM, GRAB BARS, TOILET ACCESSORIES, FURNISHINGS, AND SIMILAR CONSTRUCTION TO COMPLY WITH DETAILS INDIC TED AND WITH RECOMMENDATIONS OF GYPSUM BOARD MANUFACTURER, OR IF NONE AVAILABLE, WITH "GYPSUM CONSTRUCTION HANDBOOK" PUBLISHED BY UNITED STATES GYPSUM CO. DO NOT BRIDGE BUILDING EXPANSION AND CONTROL JOINTS WITH STEEL FRAMING OR FURRING MEMBERS. BOTH SIDES OF JOINTS SHALL BE FRAMED OR FORRED INDEPENDENTLY AS INDICATED. :RS SHALL BE SECURED TO STRUCTURAL SUPPORT BY CONNECTING DIRECTLY TO STRUCTURE WHERE POSSIBLE. OTHERWISE, HANGERS CONNECT TO CAST -IN -CONCRETE INSERTS OR OTHER ANCHORAGE DEVICES OR FASTENERS AS INDICATED. DO NOT ATTACH HANGERS TO DECK TABS OR TO METAL ROOF DECK. DON T CONNECT OR SUSPEND STEEL FRAMING FROM DUCTS, PIPES, OR CONDUIT. HANGERS AND BRACES SHALL BE AT LEAST 2" CLEAR OF DUCTS, PIPE OR CONDUIT. IRS (TRACKS) SHALL BE INSTALLED AT FLOORS, CEILINGS, AND STRUCTURAL WALLS AND COLUMNS WHERE GYPSUM DRYWALL STUD SYSTEM OTHER CONSTRUCTION. 09200-33 EXTEND PARTITION FRAMING FULL HEIGHT TO STRUCTURAL SUPPORTS OR SUBSTRATES ABOVE SUSPENDED CEILINGS, EXCEPT WHERE PARTITIONS ARE INDICATED TO TERMINATE AT SUSPENDED CEILINGS. CONTINUE FRAMING OVER FRAMES FOR DOORS AND OPENINGS AND FRAME AROUND DUCTS PENETRATING PARTITIONS ABOVE CEILING TO PROVIDE SUPPORT FOR GYPSUM BOARD. 09200-34 DO NOT CONTINUE DRYWALL JOINT ABOVE THE JAMB AT DOORS AND SIMILAR OPENINGS. OFFSET DRYWALL JOINT TO CENTER OF OPENING WHERE POSSIBLE. 09200.35 ATTACH GYPSUM BOARD TO SUPPLEMENTARY FRAMING AND BLOCKING PROVIDED FOR ADDITIONAL SUPPORT AT OPENINGS AND CUTOUTS. 09200-36 COVER BOTH FACES OF STEEL STUD PARTITION FRAMING WITH GYPSUM BOARD IN CONCEALED SPACES (ABOVE CEILINGS, ETC.), EXCEPT IN CHASE WALLS WHICH ARE BRACED INTERNALLY. EXCEPT WHERE CONCEALED APPLICATION IS INDICATED OR REQUIRED FOR SOUND, FIRE, AIR, OR SMOKE RATINGS; COVERAGE MAY BE ACCOMPLISHED WITH SCRAPS NOT LESS THAN 8 SQ. FT. AREA, AND MAY BE LIMITED TO NOT LESS THAN 75% OF FULL COVERAGE. 09200-37 WHERE FEASIBLE, USE THE SAME FASTENERS TO ANCHOR TRIM ACCESSORY FLANGES AS REQUIRED TO FASTEN GYPSUM BOARD TO THE SUPPORTS. OTHERWISE, FASTEN FLANGES TO COMPLY WITH MANUFACTURER'S RECOMMENDATIONS. 09200-38 SOUND ATTENUATION BLANKETS SHALL BE INSTALLED PRIOR TO GYPSUM BOARD WHERE INDICATED UNLESS READILY INSTALLED AFTER BOARD HAS BEEN INSTALLED. 09200-39 JOINT TREATMENT SHALL BE APPLIED AT GYPSUM BOARD JOINTS (BOTH DIRECTIONS); FLANGES OF CORNER BEAD, EDGE TRIM, AND CONTROL JOINTS, PENETRATIONS, FASTENER HEADS, SURFACE DEFECTS AND ELSEWHERE AS REQUIRED TO PREPARE WORK FOR DECORATION. 09200-40 PREFILL OPEN JOINTS AND ROUNDED OR BEVELED EDGES USING SETTING -TYPE JOINT COMPOUND. 09200-41 APPLY JOINT TAPE AT JOINTS BETWEEN GYPSUM BOARDS, EXCEPT WHERE TRIM ACCESSORIES ARE INDICATED. 0920042 CAULK GAPS WHERE INTERSECTION OF CONSTRUCTION ELEMENTS IS NOT CRISP AND CONSISTENT AS APPLICABLE, UNLESS OTHERWISE NOTED. COLOR OF CAULKING SHALL MATCH ADJACENT MATERIALS AND SHALL BE APPLIED AS INCONSPICIOUSLY AS POSSIBLE. 0920043 FINISH INTERIOR GYPSUM WALLBOARD BY APPLYING JOINT COMPOUNDS IN 3 COATS (NOT INCLUDING PREFILL OF OPENINGS IN BASE); SAND BETWEEN COATS AND AFTER LAST COAT, ONLY ONE COAT IS REQUIRED ON CONCEALED DRYWALL CONSTRUCTION. 09200.44 PROVIDE FINAL PROTECTION AND MAINTAIN CONDITIONS, IN A MANNER SUITABLE TO INSTALLER, WHICH ENSURES GYPSUM DRYWALL CONSTRUCTION BEING WITHOUT DAMAGE OR DETERIORATION AT TIME OF SUBSTANTIAL COMPLETION. SECTION 09310 CERAMIC TILE 09310-1 SINGLE SOURCE MANUFACTURER: WATERPROOFING, SURFACE PREPARATION, PRIMERS, CRACK ISOLATION MEMBRANES, UNDERLAYMENTS, SETTING MATERIALS, AND GROUT MATERIALS SHALL BE PROVIDED BY A SINGLE MANUFACTURER. 09310-2 SUBMIT SHOP DRAWINGS SHOWING TILE PATTERNS AND PROPOSED JOINT LOCATIONS BASED ON VERIFIED FIELD DIMENSIONS. SUBMITTAL SHALL INCLUDE ANY DEVIATION FROM DETAILS AS SHOWN ON DRAWINGS WHICH RELATE TO CERAMIC TILE FLOORING OR BASE CONDITIONS. SUBMITTAL SHALL INCLUDE MATERIAL SAMPLES OF ALL MATERIALS USED THAT ARE VISIBLE. THIS INCLUDES, BUT IS NOT LIMITED TO GROUT, CAULKING, SEALANT, METAL SEPARATORS, ETC. 09310.3 THE MANUFACTURER SHALL WARRANT THE PERFORMANCE OF THE CERAMIC TILE FOR TEN YEARS, UPON COMPLETION OF THE INSTALLATION, WHEN INSTALLED PER CERAMIC TILE MANUFACTURER'S INSTALLATION INSTRUCTIONS. 09310-4 SYSTEM SHALL MEET TRAFFIC LEVEL PERFORMANCE EXTRA HEAVY COMMERCIAL WHEN TESTED IN ACCORDANCE WITH ASTM C 627 EVALUATING CERAMIC TILE FLOOR INSTALLATIONS, A. MEMBRANE SHALL MEET ALL ANSI A118.10 SPECIFICATIONS FOR CERAMIC WATERPROOFING MEMBRANES. B. TROWEL -APPLIED WATERPROOFING MEMBRANE SHALL BE TRIPLE FLEX WATERPROOFING, CRACK ISOLATION MEMBRANE AND BONDING MORTAR SYSTEM (324), AS MANUFACTURED BY MANUFACTURER'S SPECIFICATIONS 09310-5 REFER TO TILE COUNCIL OF AMERICA, INC. HANDBOOK, METHOD EJ171-93 FOR RECOMMENDATIONS ON LOCATING AND DETAILING VARIOUS TYPES OF CONSTRUCTION JOINTS. USE SEALANT COMPLYING WITH ASTM C920 ACCORDING TO TYPE, GRADE, CLASS AND USES REQUIRED. EXAMINE CONDITIONS UNDER WHICH CERAMIC TILE WILL BE INSTALLED AND PROCEED WITH WORK IN ACCORDANCE WITH SECTION 01710. MAXIMUM VARIATION FROM THE REQUIRED PLANE, AS SPECIFIED BY TILE COUNCIL OF AMERICA F-111-03 THROUGH F-116-03. 1. A. FLOOR SURFACES: 1/4 INCH IN 10 FEET B. WALL SURFACES: 1/4 INCH IN 10 FEET 09310-6 NOTIFY ARCHITECT AND GENERAL CONTRACTOR IN WRITING OF UNSATISFACTORY CONDITIONS. DO NOT PROCEED UNTIL UNSATISFACTORY CONDITIONS HAVE BEEN CORRECTED. 09310.7 SURFACES TO BE TILED SHALL BE STRUCTURALLY SOUND, DRY AND FREE FROM OIL, GREASE, DUST, LOOSE OR PEELING PAINT, CONCRETE SEALERS OR CURING COMPOUNDS. ALL CONTAMINANTS MUST BE REMOVED PRIOR TO SYSTEM INSTALLATION. SURFACES MUST BE FREE OF HYDROSTATIC CONDITIONS OR OTHER MOISTURE RELATED PROBLEMS. CONFIRM LOCATION OF EXPANSION OR CONTROL JOINTS REQUIRED AND DETAILS PROVIDED ON THE DRAWINGS. INSTALL IN ACCORDANCE WITH ANSI A108.5 INSTALLATION SPECIFICATIONS FOR LATEX -MODIFIED PORTLAND CEMENT MORTAR, ANSI A108.4 INSTALLATION SPECIFICATIONS WITH ORGANIC OR EPDXY ADHESIVES, INSTALL A CONTINUOUS MEMBRANE OF AT LEAST 45 MIL THICK OVER THE ENTIRE SURFACE TO BE WATERPROOFED. INSTALL TRIPLE FLEX WATERPROOFING MEMBRANE, CRACK ISOLATION MEMBRANE AND BONDING MORTAR IN ACCORDANCE WITH MANUFACTURER'S SPECIFICATIONS PRODUCT INSTALLATION PROCEDURES FOR WATERPROOFING. 09310-8 PRIME THE SURFACE WITH PRIMER AND PATCH ADDITIVE FOLLOWING PRODUCT INSTALLATION PROCEDURES FROM MANUFACTURER'S SPECIFICATIONS INSTALL TILE IN PATTERN SHOWN ON DRAWINGS. JOINTS SHALL BE ALIGNED AND OF SAME SIZE WHEN ADJOINING TILES ON FLOOR, BASE, WALLS AND TRIM. TILE SHOULD BE CUT STRAIGHT AND HAVE EDGES ALIGNED WITH ADJACENT MATERIALS. GRIND EDGES OF CUT TILE. INSTALL TILE UNDER EQUIPMENT AND FIXTURES AND INTO RECESSES TO FORM A COMPLETE TILE COVERING. TERMINATE TILE NEATLY AT EDGES, CORNERS AND OBSTRUCTIONS WITHOUT DISRUPTING THE TILE PATTERN OR JOINTALIGNMENT. INSTALL TILE IN ACCORDANCE WITH LATEST VERSION OF TILE COUNCIL OF AMERICA, INC. METHOD F111-03 THROUGH F116-03. REFER TO DRAWING DETAILS FOR ACTUAL CONDITIONS 09310-9 INSTALL GROUT IN STRICT ACCORDANCE WITH MANUFACTURER'S SPECIFICATIONS INSTALLATION INSTRUCTIONS AND FOLLOWING THE GUIDELINES OF ANSI A108.10. INSTALL EPDXY MORTAR AND GROUT IN STRICT ACCORDANCE WITH MANUFACTURER'S SPECIFICATIONS INSTALLATION INSTRUCTIONS AND FOLLOWING THE GUIDELINES OF ANSI A108.6. 09310-10 EXPANSION AND CONTROL JOINTS: INSTALL EXPANSION AND CONTROL JOINTS IN ACCORDANCE WITH TILE COUNCIL OF AMERICA, INC. METHOD EJ171. 09310-11 COMPLETELY REMOVE ALL GROUT HAZE AND RESIDUE FROM THE SURFACE OF THE CERAMIC OR STONE TILE. GROUT JOINTS MUST BE CLEAN AND FREE OF STANDING WATER, DUST AND ANY FOREIGN SUBSTANCES. 09310-12 PROTECT FLOORS FROM GENERAL FOOT TRAFFIC FOR AT LEAST 72 HOURS AFTER GROUTING HAS BEEN COMPLETED. PROTECT TILE INSTALLATION FROM FREEZING AND WATER IMMERSION FOR AT LEAST 21 DAYS AFTER INSTALLATION IS COMPLETE. PROTECT ALL FLOOR TILE INSTALLATIONS WITH KRAFT PAPER OR OTHER HEAVY BREATHABLE COVERING DURING THE CONSTRUCTION PERIOD TO PREVENT DAMAGE OR STAINING. 09310-13 FIELD MOCK-UP: INSTALL A FULLY FINISHED MOCK-UP FOR EACH TYPE TILE INSTALLATION. MOCK-UP SHALL BE A MINIMUM OF 10'0"X 10'0" AND WILL BE REVIEWED FOR JOINT QUALITY, COLOR RANGE, PATTERN AND WORKMANSHIP. 09310-14 EXTRA STOCK: FURNISH EXTRA STOCK OF QUANTITY EQUAL TO 5% OF AMOUNT INSTALLED, IN FULL-SIZE UNITS, FOR EACH TYPE, COLOR, SIZE AND FINISH INCLUDED IN THE WORK. ALL PRODUCTS SUPPLIED SHALL BE DELIVERED IN ORIGINAL, UNOPENED PACKAGES WITH LABELS IDENTIFYING PRODUCTS LEGIBLE AND INTACT. 09310-15 ALL PRODUCTS SUPPLIED SHALL BE STORED IN A DRY ENCLOSURE AND PROTECTED FROM THE WEATHER, DIRECT SUNLIGHT, SURFACE CONTAMINATION, AGING, DAMAGING TEMPERATURES, DAMAGE FROM CONSTRUCTION TRAFFIC, AND OTHER POTENTIAL ADVERSITIES. DAMAGED MATERIALS SHALL BE REMOVED FROM THE JOBSITE. 09310-16 APPLY FULL COVERAGE UNDER ALL STONE FLOORING WITH CRACK ISOLATION MEMBRANE. INSTALLATION SHALL COMPLY WITH ANSI -Al 08.17 AND TCNA-F125A-09. PREPARATION OF CRACK ISOLATION MEMBRANE SHOULD BE INSTALLED PER MANUFACTURERS RECOMMENDATIONS. MEMBRANE MATERIAL SHALL MEET ANSI -Al 18.12 REQUIREMENTS. , 1240 East 5th Avenue Tampa, FL 33605 T 813.223.2293 F 813.223.2433 www.asdsky.com _-�.'S' IRJERRA AftN W ELLN S' U J V! N LO m O�0— J m � W I N (II ° U U) J P� C v J U) CO N1 N This drawing is the property of Associa Space Design, Inc. and is not to be reproduced or copied in whole or part. 1 not to be used on any other project and i be returned upon request. Scales as sta herein are for reference only as normo reproduction processes may alter thL accuracy of original drawings. Associated Space Design, Inc. 2018 NO: DATE: REMARKS: REVISIONS: DRAWING TITLE'. SPECIFICATIONS PROJECT NO.: ISSUE DATE: 51394.64 05-23-18 DRAW BY: CHECKED BY: AC KN SHEET NUMBER: A0.13 SECTION 09500 ACOUSTICAL TILE CEILINGS 09650 fl TILE I 09500-1 PROVIDE MANUFACTURER'S STANDARD UNITS OF CONFIGURATION INDICATED THAT COMPLY WITH ASTM E1264 CLASSIFICATIONS AS DESIGNATED BY REFERENCE TO TYPES, PATTERNS, ACOUSTICAL RATINGS, AND LIGHT REFLECTANCE, UNLESS OTHERWISE NOTED. 09600-2 SUSPENSION SYSTEM ATTACHMENT DEVICES SHALL BE FIXED FOR FIVE (5) TIMES DESIGN LOAD INDICATED IN ASTM C635, TABLE I, DIRECT HUNG, UNLESS OTHERWISE NOTED. 09500.3 WIRE FOR HANGERS AND TIES SHALL MEET ASTM A641, CLASS I, ZINC COATING, SOFT TEMPER. 095004 PROVIDE WIRE SIZED SO THAT STRESS AT THREE (3) TIMES HANGER DESIGN LOAD (ASTM C635, TABLE I, DIRECT HUNG) SHALL BE LESS THAN YIELD STRESS OF WIRE, BUT PROVIDE NOT LESS THAN 0.106" DIAMETER (12 GAUGE). 09500-5 ACOUSTICAL CEILINGS SHALL BE INSTALLED TO COMPLY WITH THE FOLLOWING STANDARDS: A. CISCA "CEILING SYSTEMS HANDBOOK" B. ASTM C636 "STANDARD FOR INSTALLATION OF CEILING SUSPENSION SYSTEMS" C. ASTM C636 AND E580 AS APPLICABLE TO ACOUSTICAL SNAP -IN METAL PAN CEILINGS. 09600-6 WHERE ACOUSTICAL PANEL CEILINGS ARE REQUIRED TO COMPLY WITH A FIRE HAZARD CLASSIFICATION FOR FLAMESPREAD, FUEL CONTRIBUTION, AND SMOKE DEVELOPMENT, PROVIDE PANELS WHICH HAVE BEEN TESTED, RATED, AND LABELED BY UL FOR THE REQUIRED RATINGS AS LISTED IN THE "CLASSIFIED BUILDING MATERIALS INDEX" BY UL. 09600.7 PROVIDE MANUFACTURER'S STANDARD UNITS FOR CONFIGURATION INDICATED WHICH ARE PREPARED FOR MOUNTING METHOD DESIGNATED AND WHICH COMPLY WITH FS SS-S-118 REQUIREMENTS, INCLUDING THOSE INDICATED BY REFERENCE TO TYPE, FORM, PATTERN, GRADE, LIGHT REFLECTANCE COEFFICIENT, EDGE DETAIL, AND JOINT DETAIL. 09500-8 OBTAIN UNITS FROM ONE MANUFACTURER, CURED BY ONE PROCESS, AND OF UNIFORM TEXTURE AND COLOR FOR EACH TYPE REQUIRED, FOR EACH CONTINUOUS, VISUALLY RELATED AREA. DO NOT CHANGE BRANDS OF MATERIALS DURING THE COURSE OF THE WORK WITHOUT APPROVAL 09500-9 NECESSARY COMPONENTS FOR A COMPLETE SUSPENSION SYSTEM SHALL BE SUPPLIED, INCLUDING BUT NOT LIMITED TO INSERTS, ANCHORS, HANGERS, CARRYING CHANNELS, MAIN RUNNERS, CROSS RUNNERS, SPLINES, EDGE MOLDINGS, SPLICES, CLIPS, FASTENERS, TIRE WIRES, HOLD- DOWN DEVICES, AND ACCESSORIES AND DEVICES AS APPLICABLE. 09500-10 PROVIDE MANUFACTURER'S STANDARD UNITS OF METAL, FINISH, AND SHAPES RECOMMENDED FOR THE APPLICATIONS INDICATED, UNLESS OTHERWISE NOTED. 09600-11 PROVIDE EXPOSED SINGLE -FLANGE MOLDINGS FOR SUPPORT AT EDGES OF CEILING, AT WALLS, PENETRATIONS, ETC. 09500-12 PROVIDE SUSPENSION MANUFACTURER'S SPECIAL EDGE -TRIM MOLDING OF TYPES INDICATED FOR INTERRUPTIONS IN CEILING WHERE EDGES OF TILE WOULD OTHERWISE BE EXPOSED. CIRCULAR PENETRATIONS TO CEILING SHALL HAVE EDGE MOLDINGS FABRICATED TO DIAMETER REQUIRED TO FIT PENETRATION EXACTLY. 09500.13 SUBJECT TO COMPLIANCE WITH REQUIREMENTS; PROVIDE PRODUCTS BY ONE OF THE FOLLOWING MANUFACTURERS A. ARMSTRONG WORLD INDUSTRIES, INC. B. USG INTERIORS, INC. C. CELOTEX 09600-14 SUBMIT MANUFACTURER'S PRODUCT SPECIFICATIONS AND INSTALLATION INSTRUCTIONS FOR EACH ACOUSTICAL CEILING MATERIAL REQUIRED AND FOR EACH SUSPENSION SYSTEM, INCLUDING CERTIFIED LABORATORY TEST REPORTS AND OTHER DATA AS REQUIRED TO SHOW COMPLIANCE WITH THESE SPECIFICATIONS. INCLUDE MANUFACTURER'S RECOMMENDATION FOR CLEANING AND REFINISHING ACOUSTICAL UNITS, INCLUDING PRECAUTIONS AGAINST MATERIALS AND METHODS WHICH MAY BE DETRIMENTAL TO FINISHES AND ACOUSTICAL PERFORMANCE. 09500-16 SUBMIT SAMPLES FOR VERIFICATION PURPOSES OF EACH TYPE OF EXPOSED FINISH REQUIRED, PREPARED ON SAMPLES OF SIZE, THICKNESS, AND MATERIAL INDICATED FOR FINAL UNIT OF WORK. 09600-16 SUBMIT FULL-SIZE SAMPLES OF EACH TILE TYPE, PATTERN, AND COLOR REQUIRED, 09500-17 COORDINATE LAYOUT AND INSTALLATION OF ACOUSTICAL CEILING UNITS AND SUSPENSION SYSTEM COMPONENTS WITH OTHER CONSTRUCTION THAT PENETRATES CEILINGS OR IS SUPPORTED BY THEM, INCLUDING LIGHT FIXTURES, HVAC EQUIPMENT, FIRE -SUPPRESSION SYSTEM COMPONENTS, AND PARTITION SYSTEM. 09600-18 DELIVER ACOUSTICAL CEILING UNITS TO PROJECT SITE IN ORIGINAL UNOPENED PACKAGES AND STORE THEM IN A FULLY ENCLOSED SPACE WHERE THEY WILL BE PROTECTED AGAINST DAMAGE FROM MOISTURE, DIRECT SUNLIGHT, SURFACE CONTAMINATION, OR OTHER CAUSES. 09500-19 EXAMINE SUBSTRATES AND STRUCTURAL FRAMING TO WHICH CEILING SYSTEM ATTACHES OR ABUTS, WITH INSTALLER PRESENT, FOR COMPLIANCE WITH REQUIREMENTS SPECIFIED IN THIS AND OTHER SECTIONS THAT AFFECT INSTALLATION AND ANCHORAGE OF CEILING SYSTEM. DO NOT PROCEED WITH INSTALLATION UNTIL UNSATISFACTORY CONDITIONS HAVE BEEN CORRECTED. 09600-20 DO NOT INSTALL INTERIOR ACOUSTICAL CEILINGS UNTIL SPACE IS ENCLOSED AND WEATHERPROOF, WET WORK IN SPACE IS COMPLETED AND NOMINALLY DRY, WORK ABOVE CEILINGS IS COMPLETE, AND AMBIENT CONDITIONS OF TEMPERATURE AND HUMIDITY WILL BE CONTINUOUSLY MAINTAINED AT VALUES NEAR THOSE INDICATED FOR FINAL OCCUPANCY. 09500-21 MEASURE EACH CEILING AREA AND ESTABLISH LAYOUT OF ACOUSTICAL UNITS TO BALANCE BORDER WIDTHS AT OPPOSITE EDGES OF EACH CEILING. AVOID THE USE OF LESS -THAN- HALF WIDTH UNITS AT BORDERS AND COMPLY WITH REFLECTED CEILING PLANS WHEREVER POSSIBLE. 09500-22 LAY OUT PANELS TO MINIMIZE WASTE; REUSE CUTOFFS WHENEVER FEASIBLE, 09500-23 DIRECTIONALLY -PATTERNED ACOUSTICAL UNITS SHALL BE ARRANGED AND ORIENTED IN THE SAME DIRECTION. 09500-24 MATERIALS SHALL BE INSTALLED IN ACCORDANCE WITH MANUFACTURER'S PRINTED INSTRUCTIONS AND SHALL COMPLY WITH GOVERNING REGULATIONS, FIRE RESISTANCE RATING REQUIREMENTS AS INDICATED, AND INDUSTRY STANDARDS APPLICABLE TO THE WORK. 09500-25 -INSTALL SUSPENSION SYSTEM TO COMPLY WITH ASTM C636, WITH HANGERS SUPPORTED ONLY FROM BUILDING STRUCTURAL MEMBERS AS INDICATED. 09600-26 HANGERS SHALL BE LOCATED NEAR EACH END (WITHIN 12") AND SPACED 4'-0" ALONG EACH CARRYING CHANNEL OR DIRECT -HUNG RUNNERS, UNLESS OTHERWISE NOTED. 09500-27 HANGER WIRES SHALL BE INSTALLED AT RECESSED LIGHT FIXTURES RESTING ON SAME CEILING COMPONENT OR SUPPORTED BY CROSS TEES ON MORE THAN TWO (2) SIDES. SECURE WIRE HANGERS BY LOOPING AND WIRE -TIEING EITHER DIRECTLY TO STRUCTURES OR TO INSERTS, EYE - SCREWS OR OTHER DEVICES WHICH ARE SECURE AND APPROPRIATE FOR THE SUBSTRATE AND WHICH WILL NOT DETERIORATE OR FAIL WITH AGE OR ELEVATED TEMPERATURE. 09500-28 EDGE TRIM MOLDINGS SHALL BE INSTALLED WHERE INDICATED, AND ELSEWHERE AS NEEDED, TO CONCEAL EDGES OF ACOUSTICAL UNITS WHICH WOULD OTHERWISE BE EXPOSED TO VIEW AFTER COMPLETION OF THE WORK. ANCHOR WITH FASTENER OR SECURE IN PLACE WITH PERMANENT ADHESIVE. 09500-29 INSTALL ACOUSTICAL TILE IN ACCORDANCE WITH SUSPENSION SYSTEM 09500-30 CLEAN EXPOSED SURFACES OF ACOUSTICAL CEILINGS, INCLUDING TRIM, EDGE MOLDINGS, AND SUSPENSION MEMBERS. CLEANING AND TOUCH-UP OF MINOR FINISH DAMAGE SHALL COMPLY WITH MANUFACTURER'S INSTRUCTIONS. REMOVE AND REPLACE WORK THAT CANNOT BE SUCCESSFULLY CLEANED AND REPAIRED TO PERMANENTLY ELIMINATE EVIDENCE OF DAMAGE. 09500-31 VISIBLE SIGNS OF TOUCH-UP OR REPAIR TO EXPOSED SURFACES WILL NOT BE ACCEPTED. 09650-1 RESILIENT FLO DRING TILE INCLUDES VINYL COMPOSITION TILE, RESILIENT WALL BASE, VINYL TRANSITION STRIPS, LINOLEUM AND ANY OTHER RESILIENT FLO DRING PRODUCTS AS REQUIRED TO PERFORM THE WORK, 09660-2 VINYL COMPOE ITION TILE (VCT) SHALL BE FS SS-T-312, TYPE IV, 12" X 12" X 1/8"UNLESS INDICATED OTHERWISE. 09650-3 RESILIENT WA L BASE SHALL BE FS SS-W-40M TYPE I, IN ROLLS WITH MATCHING END STOPS AND PERFORMED OR MOLDED CORNER UNITS, 1/8" GAGE, UNLES INDICATED OTHERWISE. INSTALL STRAIGHT BASE AT CARPET AND COVE BASE ELSEWHERE. WALL BASE HEIGHT SHALL BE 2 1/2" U.N.O. 09650-4 VINYL TRANS11 ION STRIPS SHALL BE JOHNSONITE VINYL MOLDINGS OR APPROVED EQUAL. 09650-5 SUBMIT 12" X 12" SAMPLES OF EACH TYPE, COLOR AND FINISH OF EACH RESILIENT TILE REQUIRED AND OF ALL ACCESSORIES. 09650-6 INSPECT SUBF OOR SURFACES TO DETERMINE SATISFACTORY CONDITIONS IN COMPLIANCE WITH THE MANUFACTURER'S INSTRUCTIONS. ENSURE THAT THE SUBFLOOR IS FREE FROM CRACKS, HOLES, RIDGES AND COATINGS AND RESIDUES PREVENTING ADHESIVE BOND AND OTHER DEFECTS IMPP IRING PERFORMANCE OR APPEARANCE. 09650-7 REPAIR MINOR HOLES, CRACKS, DEPRESSIONS AND ROUGH AREAS, USING LEVELING AND PATCHING COMPOUNDS AS RECOMMENDED BY THE VCT 09650.8 REMOVE COATINGS ON SUBFLOOR SURFACES THAT WOULD PREVENT ADHESIVE BOND, INCLUDING CURING COMPOUNDS INCOMPATIBLE WITH VCT FLOORING AD ESIVES, PAINT, OILS, WAXES AND SEALERS. 09650-9 INSTALL RESILIENT FLOORING IN STRICT COMPLIANCE WITH MANUFACTURER'S PRINTED INSTRUCTIONS. 09650-10 EXTEND RESILIENT FLOORING INTO TOE SPACES, DOOR REVEALS AND INTO CLOSETS, AND SIMILAR OPENINGS. SCRIBE, CUT AND FIT VCT TO PERMANENT FIXTURES, BUILT-IN FURNITURE AND CABINETS, PIPES, RECEPTACLES AND PERMANENT COLUMNS, WALLS AND PARTITIONS. RUN TILE UNDER NON -PERMANENT COLUMNS AND POWER POLES PRIOR TO THEIR INSTALLATION. 09650-11 LAY TILE FROM CENTER MARKS ESTABLISHED WITH PRINCIPAL WALLS, DISCOUNTING MINOR OFFSETS, SO THAT TILES AT OPPOSITE ENDS OF ROOM ARE OF EQUAL WIDTH. ADJUST AS NECESSARY TO AVOID USE OF CUT WIDTHS LESS 1/2 TILE AT ROOM PERIMETERS. LAY TILE SQUARE TO ROOM AXIS UNLESS SHOWN OTHERWISE. 09650-12 MATCH TILES =OR COLOR AND PATTERN BY USING TILE FROM CARTONS IN SAME SEQUENCE AS MANUFACTURED AND PACKAGED, IF SO NUMBERED. CUT TILE NEATLY AROUND ALL FIXTURES. BROKEN, CRACKED, CHIPPED, DAMAGED OR DEFORMED TILES ARE NOT ACCEPTABLE. 09660-13 LAY TILE WITF GRAIN RUNNING IN ONE DIRECTION, UNLESS NOTED OTHERWISE. 09650-14 INSTALL ALL F ESILIENT FLOORING PRODUCTS WITH WATERPROOF, STABILIZED, LOW VOC TYPE ADHESIVES. 09660-16 ADHERE REST IENT FLOORING TO SUBSTRATES USING FULL SPREAD OF ADHESIVE APPLIED IN COMPLIANCE WITH FLOORING MANUFACTURER'S PRINTED INS RUCTIONS. 09650-16 IMMEDIATELY UPON COMPLETION OF RESILIENT FLOORING INSTALLATION, SWEEP OR VACUUM FLOOR THOROUGHLY. REMOVE ANY EXCESS ADHESIVE OR OTHER BLEMISHES USING CLEANER RECOMMENDED BY TILE MANUFACTURER, 09650-17 THE CONTRACTOR SHALL WAX AND POLISH ALL RESILIENT FLOORING ACCORDING TO THE MANUFACTURER'S INSTRUCTIONS, UNLESS NOTED OTHERWISE. 09650-18 PROTECT FL ORING AGAINST DAMAGE DURING CONSTRUCTION TO COMPLY WITH RESILIENT TILE MANUFACTURER'S INSTRUCTIONS. 09660.19 PROTECT FL ORING AGAINST DAMAGE FROM ROLLING LOADS FOR INITIAL PERIOD FOLLOWING INSTALLATION BY COVERING WITH PLYWOOD OR HARDBOARD. USE DOLLIES TO MOVE STATIONARY EQUIPMENT OR FURNISHINGS ACROSS FLOORS. 09660-20 APPLY PROT CTIVE FLOOR POLISH TO RESILIENT TILE FLOORING SURFACES FREE FROM SOIL, EXCESS ADHESIVE, OR SURFACE BLEMISHES. USE COMMERCIALLY AVAILABLE PRODUCT ACCEPTABLE TO RESILIENT TILE MANUFACTURER. POLISH RESILIENT FLOORING IMMEDIATELY PRIOR TO SUBSTANTIA COMPLETION. 09650-21 FIELD MOCK- P: INSTALL A FULLY FINISHED MOCK-UP FOR EACH TYPE TILE INSTALLATION. MOCK-UP SHALL BE A MINIMUM OF 10'0"X 10'0" AND WILL BE REVIEWED FOR JOINT QUALITY, COLOR RANGE, PATTERN AND WORKMANSHIP. 09650-22 EXTRA STOCK: FURNISH EXTRA STOCK OF QUANTITY EQUAL TO 5% OF AMOUNT INSTALLED, IN FULL-SIZE UNITS, FOR EACH TYPE, COLOR, SIZE AND FINISH INCLUDED IN THE WORK. ALL PRODUCTS SUPPLIED SHALL BE DELIVERED IN ORIGINAL, UNOPENED PACKAGES WITH LABELS IDENTIFYING PRODUCTS LEGIBLE AND INTACT. 09650-23 ALL PRODUC S SUPPLIED SHALL BE STORED IN A DRY ENCLOSURE AND PROTECTED FROM THE WEATHER, DIRECT SUNLIGHT, SURFACE CONTAMINA ION, AGING, DAMAGING TEMPERATURES, DAMAGE FROM CONSTRUCTION TRAFFIC, AND OTHER POTENTIAL ADVERSITIES. DAMAGED MATERIALS HALL BE REMOVED FROM THE JOBSITE, SECTION 09680 CARPET / CARPET TILE 09680-1 THE CONTRP CTOR SHALL BE HELD RESPONSIBLE FOR THE SCHEDULING, RECEIVING, INSPECTION AND INSTALLATION OF THE GOODS AND MATERIALS 10 BE USED IN THIS WORK. CARPET GOODS SHALL BE DELIVERED TO THE JOB SITE IN THE MANUFACTURER'S ROLLS OR PACKAGES AND SHALL E E CLEARLY MARKED AS TO SIZE, DYE LOT AND MATERIAL. 09680-2 THE CONTRACTOR SHALL VISIT THE SITE AND SHALL VERIFY ALL DIMENSIONS AND OTHER CONDITIONS AS REQUIRED TO ACCURATELY LAY OUT AND FIT ALL TEMS SPECIFIED. 09680-3 THE CONT CTOR SHALL BE RESPONSIBLE FOR DETERMINING ANY DISCREPANCIES BETWEEN ACTUAL CONDITIONS AND THOSE SHOWN ON THE DRAWINGS. ANY DIFFERENCE FOUND SHALL BE SUBMITTED TO THE ARCHITECT FOR CONSIDERATION PRIOR TO PROCEEDING WITH THE WORK. 09680-4 THE CONT CTOR SHALL BE TOTALLY RESPONSIBLE FOR THE ACCURACY OF HIS MEASUREMENTS ON TOTAL YARDAGE REQUIREMENTS TO BE 09680-5 THE CONTRACTOR SHALL BE RESPONSIBLE FOR THE SECURITY OF ALL GOODS STORED ON THE JOB SITE. 09680-6 BEFORE ORDERING ANY MATERIALS OR FABRICATING ANY WORK, THE CONTRACTOR SHALL VERIFY ALL MEASUREMENTS AND CONDITIONS AT THE SITE FOR ALL WORK WHICH MUST BE ACCURATELY FITTED TO OTHER CONSTRUCTION, INCLUDING WALL-TO-WALL, OFFSET, DOOR AND OTHER DIMENSIONS CONTROLLED BY OTHER TRADES AND SHALL BE RESPONSIBLE FOR THE CORRECTNESS OF THE SAME. 09680-7 COMPLY WITH CARPET MANUFACTURER'S INSTALLATION RECOMMENDATIONS TO PREPARE SUBSTRATES INDICATED TO RECEIVE CARPET INSTALLATION. LEVEL SUBFLOOR TO WITHIN 1/4" IN 10 FEET, NONCUMULATIVE, IN ALL DIRECTIONS. SAND OR GRIND PROTRUSIONS, BUMPS AND RIDGES TO BE SMOOTH. PATCH AND REPAIR CRACKS AND ROUGH AREAS. FILL DEPRESSIONS. USE LEVELING AND PATCHING COMPOUNDS TO FILL CRACKS AN DEPRESSIONS IN SUBFLOOR AS RECOMMENDED BY THE CARPET MANUFACTURER. 09680-8 ALL CARPE11 OF THE SAME SPECIFICATION SHALL COME FROM THE SAME DYE LOT AND MUST MEET INDUSTRY STANDARDS FOR SIDE TO SIDE MATCH. 09680-9 THE CONTR NCTOR SHALL USE LOW VOC ADHESIVE (LESS THAN 50 g/L) AS RECOMMENDED BY THE MANUFACTURER. 09680-10 SUBMIT THE MANUFACTURER'S INSTALLATION MANUAL, MAINTENANCE GUIDE AND STANDARD WARRANTY FOR ALL SPECIFIED CARPETS, 09680-11 SUBMIT THREE 24" X 24" SAMPLES OF ALL ORDERED DYE LOTS FOR SPECIFIED CARPETS. 09680-12 SUBMIT S MING LAYOUT SHOP DRAWINGS FOR REVIEW AND APPROVAL BY THE ARCHITECT PRIOR TO INSTALLATION. DIRECTION OF SEAMING AND VARIO S COLOR AND PATTERN LOCATIONS SHALL BE SHOWN ON THE SHOP DRAWINGS. 09680.13 CARPET SHALL BE INSTALLED BY THE'DIRECT GLUE DOWN' METHOD USING THE MANUFACTURER'S MOST STRINGENT RECOMMENDATIONS AND REQUIREMENTS. INSTALL STABILIZED, LOW VOC TYPE ADHESIVE. VERIFY COMPATIBILITY OF ADHESIVE AND SUBSTRATE BEFORE INSTALLATION 09680-14 INSTALLATION SHALL BE PERFORMED BY SKILLED MECHANICS IN ACCORDANCE WITH CRI STANDARD 104, "STANDARD PRACTICE FOR INSTALLATION OF TEXTILE FLOOR COVERING MATERIALS" BY THE CARPET AND RUG INSTITUTE AND WITH THE MANUFACTURER'S RECOMMENDATIONS AND INSTRUCTIONS. THE MOST STRINGENT REQUIREMENTS SHALL APPLY. INSTALLATION SHALL BE WITH THE HIGHEST DEGREE OF WORKMANSHIP. INSTALLATION CRAFTSMEN SHALL BE REQUIRED TO SHOW EVIDENCE OF AT LEAST THREE YEARS EXPERIENCE IN CARPET INSTALLATION WORK OF A SIMILAR QUALITY. 09680-15 EXTEND CARPET UNDER OPEN -BOTTOMED AND RAISED -BOTTOMED OBSTRUCTIONS AND UNDER REMOVABLE FLANGES OF OBSTRUCTIONS. EXTEND CARPET INTO CLOSETS AND ALCOVES OF ROOMS INDICATED TO BE CARPETED, UNLESS ANOTHER FLOOR FINISH IS INDICATED FOR SUCH SPACES. EXTEND CARPET UNDER ALL MOVABLE FURNITURE AND EQUIPMENT, UNLESS NOTED OTHERWISE. 09680-16 SEAMS SHALL BE PRESSED BY HAND AND/OR SUITABLE TOOL TO PRODUCE THE BEST POSSIBLE EVEN TOP PILE WIDTH -TO -WIDTH. SEAMS SHALL BE SEALED WITH APPROPRIATE SEAM SEALER. ADJACENT WIDTHS OF CARPET MUST BE INSTALLED TO FINISH AT EXACTLY THE SAME ELEVATION, OR THE WORK WILL BE REJECTED AND REPLACED AT NO ADDITIONAL COST TO THE OWNER. 09680-17 ALL CARPET WIDTHS SHALL BE INSTALLED WITH ALL ROWS OF PILE RUNNING IN THE SAME DIRECTION, UNLESS SHOWN OTHERWISE ON THE APPROVED SHOP DRAWINGS. 09680-18 THE CONTRACTOR SHALL BE RESPONSIBLE FOR ALL FLASH PATCHING AND TO HAVE THE FLOOR IN CONDITION TO RECEIVE THE SCHEDULED FLOORING. 09680-19 FIELD MOCK-UP: INSTALL A FULLY FINISHED MOCK-UP FOR EACH TYPE TILE INSTALLATION. MOCK-UP SHALL BE A MINIMUM OF 10'0"X 10'0" AND WILL BE REVIEWED FOR JOINT QUALITY, COLOR RANGE, PATTERN AND WORKMANSHIP. 09680.20 EXTRA STOCK: FURNISH EXTRA STOCK OF QUANTITY EQUAL TO 5% OF AMOUNT INSTALLED, IN FULL-SIZE UNITS, FOR EACH TYPE, COLOR, SIZE AND FINISH INCLUDED IN THE WORK. ALL PRODUCTS SUPPLIED SHALL BE DELIVERED IN ORIGINAL, UNOPENED PACKAGES WITH LABELS IDENTIFYING PRODUCTS LEGIBLE AND INTACT. 09680-21 ALL PRODUCTS SUPPLIED SHALL BE STORED IN A DRY ENCLOSURE AND PROTECTED FROM THE WEATHER, DIRECT SUNLIGHT, SURFACE CONTAMINATION, AGING, DAMAGING TEMPERATURES, DAMAGE FROM CONSTRUCTION TRAFFIC, AND OTHER POTENTIAL ADVERSITIES. DAMAGED MATERIALS SHALL BE REMOVED FROM THE JOBSITE. 09680-22 CLEAN OLD CARPET PRIOR TO REMOVAL. 09680-23 VACUUM -CLEAN SURFACES THOROUGHLY, IMMEDIATELY BEFORE INSTALLATION. 09680.24 CLEAN NEW CARPET THOROUGHLY WITH A HIGH -EFFICIENCY PARTICULATE AIR (HEPA) FILTRATION VACUUM. 09680.25 CHECK SUBSTRATES TO ENSURE THAT NO DUSTING WILL OCCUR THROUGH INSTALLED CARPET. APPLY SEALER ON POROUS CONCRETE SURFACES WHERE REQUIRED TO PREVENT DUSTING. 09680-26 PRE -VENTILATE CARPET. UNROLL AND AIR OUT CARPET IN A WELL -VENTILATED, UNINHABITED SPACE FOR A MINIMUM OF SEVERAL HOURS, PREFERABLY A FEW DAYS, PRIOR TO INSTALLLATION. 09680-27 INSTALL CARPET AFTER ALL WET WORK IN SPACES IS COMPLETE AND DRY, AND AMBIENT TEMPERATURE AND HUMIDITY CONDITIONS ARE MAINTAINED AT THE LEVELS INDICATED FOR PROJECT WHEN OCCUPIED FOR ITS INTENDED USE. 09680-28 PROVIDE MAXIMUM VENTILATION DURING INSTALLATION. 09680-29 VACATE AND VENTILATE SPACE FOR AS LONG AS POSSIBLE (UP TO TWO WEEKS) AFTER INSTALLATION. SECTION 09700 WALL COVERING 09700-1 VINYL WALL COVERING SHALL COMPLY WITH FS CCC-W-408A FOR THE TYPE AND CLASS REQUIRED AND AS SCHEDULED. PROVIDE CLASS 2 MILDEW -RESISTANT OSNABURG OR DRILL BACKING. COMPLY WITH ASTM D 1308 FOR DETERMINING STAIN RESISTANCE, 09700.2 WALL COVERINGS SHALL BE CLASS A WITH A FLAME SPREAD OF 25 OR LESS AND SMOKE DEVELOPMENT OF 450 OR LESS AS PER ASTM E 84. 09700.3 VINYL WALL COVERING SHALL NOT BE INSTALLED ON EXTERIOR BUILDING WALLS UNLESS SPECIFIED TO BE MICROVENTED BY MANUFACTURER. NOTIFY THE ARCHITECT IN THE CASE OF CONFLICTS WITHIN THE CONTRACT DOCUMENTS. 09700-4 INSTALL MANUFACTURER'S RECOMMENDED ADHESIVE, PRIMER AND SEALER, MANUFACTURED EXPRESSLY FOR USE WITH THE SELECTED WALL COVERING. PROVIDE MATERIALS WHICH ARE MILDEW AND ALKALI RESISTANT, STRIPPABLE AND NON -STAINING TO THE WALL COVERING. 09700-5 SUBMIT MANUFACTURER'S PRODUCT DATA FOR EACH TYPE OF PRODUCT SPECIFIED. INCLUDE DATA ON PHYSICAL CHARACTERISTICS, FIRE AND SMOKE RATED CHARACTERISTICS, DURABILITY, AND FADE RESISTANCE. PROVIDE SHOP DRAWINGS SHOWING LOCATION AND EXTENT OF EACH WALL COVERING AND TERMINATION POINTS. 09700-6 PROVIDE SAMPLE OF EACH WALL COVERING SPECIFIED, THE SAMPLES SHALL BE LARGE ENOUGH TO SHOW THE FULL PATTERN REPEAT. SMALL PATTERN SAMPLES SHALL BE 8 1/2" X 11" MINIMUM SIZE. 09700-7 SUBMIT MANUFACTURER'S INSTRUCTION ON MAINTENANCE, CLEANING PRODUCTS AND METHODS TO BE USED ON EACH WALL COVERING USED 09700-8 CLIMATIZE WALL COVERINGS BY REMOVING THEM FROM THE PACKAGING IN THE INSTALLATION AREA NOT LESS THAN 24 HOURS PRIOR TO INSTALLATION. 09700-9 FOLLOW MANUFACTURER'S PRINTED INSTRUCTIONS FOR SURFACE PREPARATION. PRIME NEW GYPSUM BOARD WITH A RECOMMENDED LOW VOC PRIMER. ALLOW NEW PLASTER TO CURE AND TREAT AREAS OF HIGH ALKALINITY. 09700-10 COMPLY WITH MANUFACTURER'S PRINTED INSTRUCTIONS FOR INSTALLATION OF WALL COVERINGS, ACCESSORIES AND RELATED PRODUCTS. 09700-11 INSTALL WALL COVERINGS WITH NO GAPS, OVERLAPS OR FRAYING SEAMS. PLACE WALL COVERINGS CONTINUOUSLY OVER OUTSIDE AND INSIDE CORNERS. INSTALL SEAMS VERTICAL AND PLUMB AT NO LESS THAN 6 INCHES FROM OUTSIDE CORNERS AND 3 INCHES FROM INSIDE CORNERS. NO HORIZONTAL SEAMS. REMOVE AIR BUBBLES, WRINKLES AND OTHER DEFECTS. TRIM EDGES FOR PATTERN MATCH AND TIGHT CLOSURE AT SEAMS AND EDGES. 09700-12 REMOVE EXCESS ADHESIVE AT FINISHED SEAMS, EDGES AND ADJACENT SURFACES. 09700.13 ALL WALL COVERING SHALL TERMINATE AT AN APPROPRIATE REVEAL, BREAK OR INSIDE CORNER, ANY WALLCOVERING TERMINATING AT AN OUTSIDE CORNER SHALL RECEIVE A FLOOR TO CEILING CORNER GUARD, APPROVED BY THE ARCHITECT. 09700-14 PROVIDE AN ON -SITE 2-DROP MOCK-UP OF EACH SCHEDULED WALLCOVERING FOR EVALUATION OF WORKMANSHIP. DO NOT PROCEED WITH REMAINING WORK UNTIL WORKMANSHIP AND OVERALL APPEARANCE ARE APPROVED BY ARCHITECT. THE APPROVED MOCK-UP'S MAY NOT REMAIN AS PART OF THE COMPLETED WORK UNLESS AGREED UPON BY OWNER AND ARCHITECT IN ADVANCE. 09701-22 FIELD MEASURE EACH WALL AREA WHICH IS TO RECEIVE THE ACOUSTICAL TREATMENT TO ESTABLISH THE EXACT LAYOUT OF THE UNITS AS SHOWN ON ELEVATION. APPLY THE FRAMEWORK IN THE AREAS TO RECEIVE THE ACOUSTICAL WALL TREATMENT AS SHOWN ON THE DRAWINGS. SECURE THE FRAMEWORK WITH SUITABLE MASTIC AND SPECIAL, HEAVY DUTY, ONE INCH DIVERGING STAPLES LOCATE NOT MORE THAN 2 INCHED ON CENTER. E. OTHER FASTENERS MAY BE USED AS REQUIRED FOR SPECIFIC SUBSTRATES, PROVIDING THEY ARE IN STRICT ACCORDANCE WITH THE MANUFACTURER'S PRINTED INSTRUCTIONS AND COMPLY WITH GOVERNING REGULATIONS AND FIRE RESISTANCE RATING REQUIREMENTS SPECIFIED. 09701-23 INSTALL THE FRAMEWORK PLUMB AND STRAIGHT, FLUSH IN PROPER ALIGNMENT. INSTALL THE SUBSURFACE MATERIAL, CONTINUOUS AND FLUSH, TO THE SHOULDER OF THE TRACK. CUT THE FABRIC FROM EACH ROLL MARKING AND MAINTAINING SEQUENCE OF DROPS AND MATCHING DIRECTION OF WEAVE FOR SEQUENTIAL AND UNIFORM INSTALLATION. ASDSKY 1240 East 5th Avenue Tampa, FL 33605 T 813.223.2293 F 813.223.2433 www.asdsky.com N 0) co J (6 LL 3 t � �U S � U) J �U) Co 0 r` D_ NI This drawing is the property of Associated Space Design, Inc. and is not to be reproduced or copied in whole or part. It is not to be used on any other project and is to be returned upon request. Scales as stated herein are for reference only as normal reproduction processes may alter the accuracy of original drawings. Associated Space Design, Inc.2018 NO: DATE: REMARKS: REVISIONS: AWING TITLE: SPECIFICATIONS 51394.64 AC 05-23-18 all A0m14 I 16) / A7.01 _ �_ -F, 6 12 1 p•, _ .. .. A_ PACK& ILL SECURITY 11 FE 112 5 /hh' `O 0Q o DR- C BOH A6.04 / 3 ¢' 1 111 � ' a - 1 6-11/44 1 O R ;I 1 TECH CL 1 P.O.S. 115 R-� 110 2 2 2> SECURE PANTRY 114 1 �__ ♦2ETAILI II ® A6.02 RETAIL =GARDE N= 6 = 4 1 9H 103 �— �� _ 102 - M 3 — ill w _ 1 — EX-2 CORRIDOR 0 6 i C12) O f 108 JC EC L --1 _ 3 - -I F713) I� 17 ALCOVE 1 (I _ _ _ �1 A6.01 12 106 A6.03 F7 11) 11 1 11O CHECK -IN LIVING RM CONSULTING J 1 OFFICE 1 11 I �1 if C7 ��- 107 1 L104 100 1b1 ` 4) 1- QA6.01 / 9 RESTROOM 1 - 1 11) 11 11 �� 105 A6.01 O U �11 I I I I I (1-7) 07 - '4, 17 4' 4' — r Ll IT] 1 1/8r' 1'-0" 2 CONSTRUCTION PLAN DEMOLITION PLAN 0.0 GENERAL DEMOLITION NOTES: O EXISTING ELECTRICAL PANELS TO REMAIN. PROTECT DURING DEMOLITION AND 0.0.1 DEMOLITION CONSISTS OF PERFORMING ALL DEMOLITION OF EXISTING CONSTRUCTION CONSTRUCTION DR-1 OFFICE - NEW T-0" SOLID WOOD DOOR W/ FULL GLASS PANEL AND SIDELIGHT, HOLLOW METAL FRAME. PROVIDE WHICH IN ITS PRESENT POSITION WILL INTERFERE WITH THE COMPLETED NEW CONSTRUCTION LEVER LOCKSET W/ OFFICE FUNCTION &DOME STYLE DOOR STOP AND CONCEALED CLOSER. LOWVOLTAGETO 2O REMOVE EXISTING TOILET, SINK, AND ACESSORIES. SALVAGE SINK FOR CABLE OL 3 AND TO PERFORM ANY OTHER CUTTING OR PATCHING OF EXISTING CONSTRUCTION AS SHOWN CONTROL PANEL ON THE DRAWINGS. RELOCATION DR-2 SECURITY - NOT USED THIS LOCATION 3 GENERAL NOTE: REMOVE EXISTING LIGHT FIXTURES, CEILING TILE, GRID, AND SEC NEW 3'-0" HOLLOW METAL STEEL SECURITY DOOR W/HONEYCOMB CORE, 18 GAUGE, HOLLOW METAL FRAME. 0.0.2 CLEAN BASE BUILDING CURTAINWALL GLASS, FRAMES AND SILLS OR DRIPS, SPILLS AND HARD SURFACE CEILINGS THROUGHOUT, TYP. DR-3 PANTRY- PROVIDE LEVER LOCKSET W/ STORAGE FUNCTION & DOME STYLE DOOR STOP AND CONCEALED CLOSER. FAIL DEBRIS. REPAIR ANY DAMAGE CAUSED BY DEMOLITION. ® EXISTING WINDOWS TO REMAIN. PROTECT DURING DMEOLITION AND SECURE CARD READER, REFER TO SECURITY DRAWINGS. 0.0.3 ALL EXISTING DOORS, FRAMES, DOOR HARDWARE, LIGHT FIXTURES, SWITCHES NOT BEING CONSTRUCTION clloR-4 RESTROOM - NEW T-0" SOLID WOOD DOOR, HOLLOW METAL FRAME. PROVIDE LEVER LOCKSET W/ PRIVACY FUNCTION & REUSED FOR THIS PROJECT SHALL BE STORED FOR THE TENANT OR OWNER AS REQUIRED. O5 NOT USED DOME STYLE DOOR STOP AND CONCEALED CLOSER. CONSULT WITH ARCHITECT FOR VERIFICATION. 6 CONTRACTOR TO VERIFY CONDITION OF EXTERIOR DOOR AND FRAME REMOVE / DR-5 ADMIN - NOT USED THIS LOCATION. 0.0.4 PATCH ALL FLOOR, CEILING AND WALL SURFACES AS WELL AS ALL ADJACENT SURFACES EFFECTED BY DEMOLITION WITH SIMILAR MATERIALS AS NECESSARY TO ACHIEVE UNIFORM, NEW APPEARANCE (I.E. GWB PERIMETER WALLS, DEMISING WALLS, CORE ETC.). PATCHES SHALL BE O EXISTING STOREFRONT YSTSEM AND DOOR TO REMAIN. PROTECT DURING DR-6 B.O.H. - NEW T-0" SOLID WOOD DOOR, HOLLOW METAL FRAME. PROVIDE LEVER LOCKSET W/ OFFICE FUNCTION INPERCEPTIBLE. DEMOLITION AND CONSTRUCTION DOME STYLE DOOR STOP AND CONCEALED CLOSER. PROVIDE CARD READER - SEE SECURITY DRAWINGS. LATCH SIDE OF DOOR (REMOVAL OF PARTITIONS, ETC.) CAUSES UNEVENNESS IN ® EXISTING CMU WALL TO BE PARTIALLY DEMOLISHED FOR NEW OPENINGS. ` DR-7 TECH NEW S-0" SOLID WOOD DOOR, HOLLOW METAL FRAME. PROVIDE LEVER LOCKSET W/ STORAGE FUNCTION & 0.0.5 IN ALL AREAS WHERE DEMOLITION THE FLOOR. THE CONTRACTOR SHALL PATCH LEVEL THE FLOOR RECEIVE FINISHED COORDINATE WITH CONSTRUCTION PLAN CLOSET- DOME STYLE DOOR STOP. PROVIDE CLOSER, PROVIDE CARD READER - SEE SECURITY DRAWINGS. FLOORING. 9 NOT USED DR-9 REAR - NEW HOLLOW METAL DOOR AND FRAME. DOOR TO RECEIVE CARD READER, PANIC HARDWARE W/ REQUEST 3GANG BOX ITTOSWGLE 0.1 DEMOLITION INCLUDES BUT IS NOT LIMITED TO THE FOLLOWING: 10) SALVAGE EXISTING PNEUMATIC TUBES, CASH DRAWER, AND ALL RELA ED POWER TO EXIT UNIT &ACCESS CONTROL DOOR ACTUATORS IN INTERIOR DOOR FRAMES, REFER TO REAR DOOR 1.0.1 FURTHER DEMOLITION ADMINISTRATIVE REQUIREMENTS ARE TO BE PROVIDED PER AND DATA CONNECTIONS. REMOVE EXISTING SAFE ELEVATION. VON DUPRIN LATCH DEVICE TO BE L-NL EXTERIOR TRIM PLATE MODEL QEL-98-LNL-06-36-US26D- CONTACT ARCHITECT LHR (FROM EXTERIOR SIDE). SEE PRODUCT APPROVAL INFORMATION ON SHEET AO.1 ACCESS CO NTRDE SPECIFICATIONS SHEET OR MANUAL. IF NEITHER IS PROVIDED, PLEASE FY IMMEDIATELY FOR VERIFICATION. 11) REMOVE EXISTING MILLWORK TO BE OUNTEDER TO BE MOUNTED EX-1 ENTRANCE- EXISTING DOOR AND FRAME TO REMAIN, PATCH AND REPAIR AS REQUIRED TO ACHEIVE LIKE NEW OUTSIDE OF BUILDING 0.1.1 PARTITIONS 12) SALVAGE EXISTING FIRE EXTINGUISHER FOR REUSE. COORDINATE WI H APPEARANCE. A. REMOVAL OF EXISTING PARTITIONS, INCLUDING DOORS, FRAMES, AND THERMOSTATS, CONSTRUCTION PLAN ELECTRICAL WITHIN PARTITIONS SHALL BE REMOVED AS INDICATED ON THE DRAWINGS, 13) REMOVE EXISTING DRINKING FOUNTAIN EX-2 ENTRANCE EXISTING DOOR, FRAME, AND PANIC BAR TO REMAIN. IF DOOR OR DOOR FRAME THAT IS PART OF THE GC TO RELOCATE ANY THERMOSTAT TO A LOCATION SUITABLE BY ARCHITECT AND MEP REAR- ACCESS CONTROL SECURITY PLAN SHOWS SIGNS OF DAMAGE, RUST, HARDWARE FAILURE, OR EXCESSIVE SURFACE MOUNTED CATCH WEAR THAT WILL LIKELY CAUSE FUTURE FAILURE OR SECURITY WEAKNESS THE DOOR AND/OR/DOORO ACHIEVE FRAME MOUNTED ON DOOR FRAME ENGINEER. 14) REMOVE EXISTING VAULT DOOR SHALL BE REPLACED. FOR MINOR WEAR AND TEAR, DOOR CAN BE PATCHED AND REPAIRED TO ACHIEVE LIKE NEW CONDITION. PROVIDE CARD READER B. ALL EXISTING DOORS DESIGNATED FOR REMOVAL INCLUDING FRAMES SHALL BE REUSED WHERE THE SAME TYPE DOOR IS APPLICABLE U.N.O.. ALL REUSED DOORS TO BE REFINISHED / 15) REMOVE EXISTING PHONE BOARD AND IT EQUIPMENT. REFER TO MEP EX-3 ELEC. PANEL EXISTING DOOR AND FRAME TO REMAIN. PATCH AND REPAIR AS REQUIRED TO ACHEIVE LIKE NEW REPAINTED AS SPECIFIED WITH BLEMISHES REPAIRED. ALL EXISTING HARDWARE SHALL BE DOCUMENTS FOR MORE INFORMATION RM. . APPEARANCE. RETAINED FOR REUSE AS NOTED IN THE DEMOLITION PLAN STANDARDS. ANY MATERIALS SHALL 16 REMOVE EXISTING ATM AND TRIM KIT BE GROUPED AND STACKED NEATLY IN ONE LOCATION. PROTECT ALL ITEMS FROM DAMAGE. IF DOOR & DOOR HARDWARE NOTES: ITEMS REMOVED ARE NOT REQUIRED BY EITHER OWNER OR TENANT THEY SHALL BECOME THE 17 EXISTING EXTERIOR SOFFIT AND LIGHTING TO REMAIN. PROTECT DURI G PROPERTY OF THE CONTRACTOR AND REMOVED FROM THE SITE AS WORK PROGRESSES. DEMOLITION AND CONSTRUCTION 1. ALL HARDWARE TO BE ADA COMPLIANT. 2. GC IS RESPONSIBLE FOR ACQUIRING A LOCKSMITH THAT WILL INSTALL A PUSH BAR REQUEST TO EXIT UNIT FOR THE REAR 0.1.2 CEILING 18) EXISTING DRIVE THRU COMPONENTS AND STRUCTURE TO REMAIN. PR DTECT EXTERIOR DOOR. THE LOCKSMITH ALSO NEEDS TO BE RESPONSIBLE FOR INSTALLING THE ACCESS CONTROL DOOR EMOVE SPECIFIED LIGHTS (REFER TO CEILING PLAN IF REQUIRED). DURING DEMOLITION AND CONSTRUCTION ACTUATORS IN THE INTERIOR DOOR FRAMES. ER HARDWARE PROVIDE A QUOTE 9 A6.03 A6.03- 5 _ PUSH BAR POWER SUPPLY SECURITY DOOR CONTACT VON DUPRIN / PUSH BAR 06 C C 1 /8" = 1'-01 ' O GC TO PROVIDE BLOCKING AT ALL MILLWORK LOCATIONS AS REQUIRED O GC TO PROVIDE BLOCKING AT TRELLIS WALL FROM FLOOR TO CEILING FOR TRELLIS SUPPORT AND SHELVING POWER SUPPLY REQUIRES 110VAC O3 GC TO PROVIDE AND INSTALL BLOCKING FOR WALL MOUNTED TV BRACKET CONFIRM LOCATION, MOUNTING HEIGHTS, AND EQUIPMENT REQUIREMENTS W/ TENANT ® EXISTING ELEC.PANELS TO REMAIN - PROTECT DURING DEMO AND CONSTRUCTION - PANELS DOORS TO RECEIVE LOCKS IF NOT ALREADY PRESENT OS MOP SINK GC TO PROVIDE AND INSTALL '3M'SECURITY WINDOW FILM ON ANY EXISTING WINDOWS AND NEW STOREFRONT GLAZING. HINGE SIDE OF DOOR PRICE AS SEPARATE LINE ITEM LJ MILLWORK SHELVING UNIT - GC TO PROVIDE BLOCKING IN WALL FOR PRODUCT DISPLAY - REFER TO ELEVATIONS FOR MORE 3/4" CONDUIT TO SINGLE INFORMATION GANG BOX / ® GC TO INFILL TO MATCH ADJACENT CONSTRUCTION. PARTITION FACE TO BE FLUSH WITH ADJACENT PARTITION O9 PROVIDE BLACK OUT FILM AT INTERIOR SIDE OF EXISTING JUNCTION BOX TO WINDOW TO REMAIN CONNECT LATCH RETRACTOR POWER 1 O REPAINT EXISTING FIRE EXTINGUISHER CABINET. GC TO TO PUSH BAR CONFIRM CABINET AND EXTINGUISHER IS IN GOOD WORKING ORDER. REPLACE IF REQUIRED. FURR OUT PARTITION AS DOOR CORD - WITH EXCABLEUR FL 11 NEEDED CLOSE WALL OPENING WITH CONSTRUCTION METHODS AND MATERIALS MATCHING EXISTING CONSTRUCTION. GC TO CONFIRM 12) GC TO PROVIDE 6- 0" WIDE, 4" THICK, 3,000 PSI CONCRETE SIDEWALK WITH WELDED WIRE MESH A. R B. REMOVE EXISTING CEILING TILE. REUSE GRID AS NOTED IN THE DEMOLITION PLAN STANDARDS. 3. THE LOCKSMITH SHOULD EVALUATE ALL DOORS AND FRAMES AND SELECT THE P REPAIR ANY DAMAGE TO EXISTING GRID IF IT IS REUSED. WITH PRODUCT SPECIFICATIONS TO THE GC, GC SENDS THE DOOR HARDWARE QUOTE TO THE LOW VOLTAGE INSTALLER REAR DOOR INTERIOR ELEVATION / DIAGRAM OF SECURITY SYSTEMS C. EXISTING DIFFUSERS, EXIT SIGNS, ETC. SHALL BE REUSED AS IF IN GOOD CONDITION. (CURRENTLY SCARSDALE) AND THE PHYSICAL SECURITY TECHNOLOGY ADMINISTRATOR FOR REVIEW AND SIGN -OFF THAT LOCATION ARE TO REMAIN AS EXISTING. GC TO NOTIFY ARCHITECT AND OWNER OF ANY EXTREME THE HARDWARE IS IN FACT COMPATIBLE WITH THE ACCESS CONTROL SYSTEM. DISCREPANCIES. 4. G.C. TO COORDINATE WITH TENANT SECURITY VENDOR ON ALL LOCKING DOOR HARDWARE AND CONDUIT TO SECURITY DEVICES RELATED TO THE OPERATION OF THE SECURED DOOR. G.C. TO ENSURE THAT ALL DOORS AND FRAMES ARE 1.3 FINISHES PREPARED ACCORDINGLY TO RECEIVE THE HARDWARE AND CONDUITS AND ENSURES ALL INTERNAL DOORS THAT ARE 0. 0. REMOVE EXISTING WALLCOVERINGS U.N.O. PART OF THE SECURITY ACCESS CONTROL PLAN ARE SOLID WOOD, METAL FRAME W/ACTUATOR PLATE READY, BA. . REMOVE EXISTING CARPET ERIN 5. GC TO MEASURE IN FIELD EXISTING DOOR AND WINDOW OPENINGS TO SIZE REPLACEMENT DOORS AND OPENINGS. C. REMOVE EXISTING VCR U.N.O. 6. WOOD FINISH TO BE VENEER WITH CLEAR COAT. BIRCH OR SIMILAR. 7. HARDWARE FINISH TO BE US26D THROUGHOUT 0.1.4 HVAC A.SALVAGE FOR REUSE DIFFUSERS (INCLUDING SLOT DIFFUSERS) AS NOTED ON CONSTRUCTION/FLOOR AND WALL FINISH PLAN STANDARDS. B DEMOLITION PLAN CODED NOTES A DOOR TYPE & HARDWARE SETS 0.1.5 PLUMBING A.SPRINKLER MAIN, PIPING AND HEADS ARE TO REMAIN AS LOCATED. 1.0 GENERAL REQUIREMENTS: 1.1 GENERAL PARTITION NOTES: 0.2.0 DEBRIS REMOVAL 0.2.1 CONDUCT DEMOLITION OPERATION AND THE REMOVAL OF DEBRIS AND EQUIPMENT TO 1.0.2 CONTRACTOR SHALL BE RESPONSIBLE FOR ALL SHOP DRAWINGS AND 1.1.1 REFER TO GENERAL PARTITION PLAN TYPICALS FOR TYPICAL INFORMATION. SUBMITTALS REQUIRED BY JURISDICTION FOR PERMITTING AND FINAL INSPECTIONS. 1.1.2 THE PARTITION ABOVE DOORS SHALL BE OF SAME CONSTRUCTION AS THE ADJACENT PARTITION, INSURE MINIMUM INTERFERENCE WITH EXISTING BUSINESS OPERATION. CONSULT WITH BUILDING OWNER FOR ANY RULES AND REGULATIONS REGARDING HOURS, DUMPSTERS AND REMOVAL. THESE MAY INCLUDE BUT ARE LIMITED TO FIRE ALARM, SPRINKLER, LOW VOLTAGE 1.1.3 CAULK GAPS WHERE INTERSECTIONS OF CONSTRUCTION ELEMENTS ARE NOT CRISP AND CONSISTENT. WORK ETC. ALL LIGHT FIXTURES AND FINISH MATERIALS WILL REQUIRE FULL PRODUCT COORDINATE CAULKING & SEALING WITH SPECIFICATIONS SHEET OR MANUAL, INSTALL PER MANUFACTURERS ELEVATOR MUST BE PROTECTED AND TIMING MUST BE COORDINATED WITH BULIDING OWNER. INSURE PROTECTION OF PERSONS AROUND THE DEMOLITION AREA. USE TEMPORARY SUBMITTALS. INSTRUCTIONS. REQUIREMENTS AND ADMINISTRATIVE REQUIREMENTS 1.1.4 FLOOR LEVEL AT DOORWAYS SHALL BE PROVIDED TO INSURE TOLERANCES IN DOOR DETAILS. GC SHOULD ENCLOSURES AND OTHER SUITABLE METHODS TO LIMIT THE AMOUNT OF DUST AND DIRT RISING AND SCATTERING IN THE AIR TO THE LOWEST PRACTICAL LEVEL. CONTRACTOR SHALL KEEP 1.0.3 INSTALLATION, SUBMITTAL ARE TO BE PROVIDED PER SPECIFICATIONS SHEET OR MANUAL. IF NEITHER IS ORDER DOORS AND FRAMES FOR SCRIBE TO INSURE THAT UNDERCUT CLEARANCE PER DETAILS. 1.1.5 CONTRACTOR SHALL VERIFY EXISTING WALL / DEMISING WALL / CORE WALLS TO INFILL AND PATCH ANY OPENING DEMOLITION DEBRIS OUT OF THE BUILDING CORRIDORS. PROVIDED, PLEASE CONTACT ARCHITECT IMMEDIATELY FOR VERIFICATION. 1.0.4 CONTRACTOR TO THOROUGHLY FIELD VERIFY CONDITIONS PRIOR TO PRICING TO TO MEET REQUIRED FIRE RATINGS. 0.2.2 RELOCATION OF ITEMS INVOLVED IN THE WORK IS SUBJECT TO THE CONTRACTOR'S ABILITY INSURE FIELD CONDITIONS, DIMENSIONS AND QUANTITIES ARE CONSIDERED IN 1.1.6 DIMENSIONS: A. SCALES AS STATE fO ARE VALID ON THE ORIGINAL DRAWING ONLY. DO NOT SCALE FROM THESE DRAWINGS. TO DO SO WITHOUT PERMANENTLY DAMAGING OR MARRING THE ITEMS TO BE RELOCATED. IF THE SUBSTITUTION OF NEW PREPARATION OF FINAL COSTS. 1.0.5 CONTRACTOR TO VERIFY PENETRATIONS THROUGH PARTITIONS (SUCH AS WRITTEN DIMENSIONS TAKE PRECEDENCE OVER GRAPHIC PRESENTATION. DETAIL DIMENSIONS TAKE PRECEDENCE CONTRACTORS IS UNABLE TO RELOCATE THE ITEMS AS PRESCRIBED. MATERIAL IN LIEU OF RELOCATION IS ACCEPTABLE. CONTRACTOR MAY ELECT TO USE NEW DUCTWORK ETC.) TO INSURE THAT ADEQUATE BRACING AND REINFORCEMENT ARE OVER PLAN DIMENSIONS. MATERIALS TO MATCH EXISTING IN LIEU OF RELOCATION AT HIS OWN CONVENIENCE FOR NO PROVIDED. 1.0.6 CONTRACTOR SHALL PROVIDE LABOR + MATERIAL AS REQUIRED FOR WORK B. NOTIFY ARCHITECT OF ANY DIMENSIONAL DISCREPANCIES. ANY MODIFICATIONS OR DEVIATION TO BE BROUGHT TO ADDITIONAL COST. SYMBOL DESCRIPTION REMARKS WHICH MAY NOT FALL INTO JURISDICTION OF A SPECIFIC TRADE BUT IS REQUIRED FOR THE ATTENTION OF THE ARCHITECT FOR REVIEW AND APPROVAL. C. ALL VERTICAL DIMENSIONS SHALL BE TAKEN FROM A "BENCH MARK" OR OTHER SIMILAR GUIDE ESTABLISHED PRIOR ^---a EXISTING PARTITION TO REMAIN 0.2.3 DEBRIS RESULTING FROM THE DEMOLITION AND DEMOLITION SHALL BE REMOVED FROM PROPER JOB EXECUTION AND COMPLETION OF CONSTRUCTION. 1.0.7 CONTRACTOR AND VENDORS SHALL DETERMINE AVAILABILITY OF ALL MATERIALS. TO THE START OF CONSTRUCTION. HIGH POINTS, LOW POINTS, IRREGULARITIES IN FLOOR SLAB WHICH COULD OF OTHER TRADES OR VENDORS SHALL BE BROUGHT TO THE THE BUILDING SITE ON A DAILY BASIS. ANY DELIVERY SCHEDULE THAT POTENTIALLY MAY CAUSE COORDINATION PROBLEMS AFFECT FABRICATION / INSTALLATION, WORK 0.2.4 CLEAN ADJACENT WORK OF DUST, DIRT AND DEBRIS CAUSED BY DEMOLITION OPERATIONS. _ _ EXISTING PARTITION TO BE DEMOLISHED. DURING THE CONSTRUCTION / INSTALLATION SCHEDULE SHALL BE BROUGHT TO THE ATTENTION OF ARCHITECT. RETURN ADJACENT AREAS TO CLEAN CONDITION (SIMILAR TO PRIOR DEMOLITION) AFTER 117�� ATTENTION OF THE ARCHITECT EARLY ON, FOR POSSIBLE REEVALUATION OF MATERIAL MATERIALS: COMPLETION. EXISTING DOOR TO BE REMOVED. DESIGNATION. A IN A. INSTALL MOISTURE RESISTANT GWB AT AREAS EXPOSED TO MOISTURE INCLUDED BUT NOT LIMITED TO TOILETS, I 1. ALL DOORS ARE TO BE LOCATED AS SHOWN U.N.O. BREAKROOM COUNTERS AND OTHER SINK LOCATIONS U.N.O. 0.3.0 MISCELLANEOUS REQUIREMENTS I B. ALL NECESSARY WOOD BLOCKING / GROUNDS ETC. ARE TO BE FIRE RETARDANT TREATED GC SHALL FULLY 0.3.1 CONTRACTOR DISCOVERS EXISTING CONDITIONS WHICH ARE NOT INDICATED ON THE 1, 6„ o 4" COORDINATE SETTING AND PLACEMENT TO THESE ELEMENTS AND INSURE THAT LOCAL CODE I BUILDING DRAWINGS. CONTRACTOR SHALL NOTIFY THE ARCHITECT IMMEDIATELY BOTH VERBALLY AND IN a0 REQUIREMENTS ARE MET. WRITING PRIOR TO PROCEEDING WITH THAT PORTION OF THE WORK. EXISTING DOOR TO REMAIN. C. GROUNDS /BLOCKING MAY NOT BE WHOLLY SHOWN ON DRAWING. GOOD CONSTRUCTION PRACTICE SHALL 0.3.2 EACH SPECIFIC ITEM OF CUTTING, PATCHING OR FITTING IS NOT NECESSARILY DESCRIBED INDIVIDUALLY HEREIN. ABSENCE OF A SPECIFIC INSTRUCTION FOR CUTTING, PATCHING OR GOVERN / DETERMINE SAID USE. b D. INTERNAL WOOD RLOCKING SHALL BE PROVIDED FOR STURDY ANCHORAGE AT INTERSECTIONS OF WOOD /GLASS 1 0 BORROWED LIGHT PARTITIONS AND ADJACENT DRYWALL CONSTRUCTION. FITTING SHALL NOT RELIEVE THE CONTRACTOR FROM RESPONSIBILITY TO PERFORM AS REQUIRED COMPLETING THE WORK. A DEMOLITION PLAN GENERAL NOTES C DEMOLITION PLAN LEGEND B CONSTRUCTION PLAN GENERAL NOTES 1240 East 5th Avenue Tampa, FL 33605 T 813.223.2293 F 813.223.2433 www.asdsky.com ...-3uk ERRA �U J Q(n CV Ln N I.L 0 co -1co N � W I N � U J U) W (0 oIL t!A C I CONSTRUCTION PLAN CODED NOTES Florida Business License #: AA26001572 Registered Architect: Kenneth Cowart Registered Architect License #: AR93215 SYMBOL DESCRIPTION This drawing is the property of Associated Space Design, Inc. and is not to be EXISTING PARTITION TO REMAIN reproduced or copied in whole or part. It is not to be used on any other project and is to NEW PARTITION be returned upon request. Scales as stated herein are for reference only as normal SECURE PARTITION reproduction processes may alter the accuracy of original drawings. Associated Space Design, Inc. 2018 FIRE EXTINGUISHER AND CABINET FEC FIRE EXTINGUISHER - DRY CHEMICAL TYPE, CLASS B-C, SIZE 10 SURFACE MOUNT FIRE EXTINGUISHER FE FIRE EXTINGUISHER - DRY CHEMICAL TYPE, CLASS B-C, SIZE 10 E I CONSTRUCTION LEGEND AUG 19 %J GFm�iil )& I St• �UCI `!' ewtl F-jr1.1 €? + I G COUL� rl! ✓, ; `L WALL TYPE 1: TYPICAL UNLESS NOTED, NON -RATED WALL TO 6" �— ABOVE CEILING. 3-5/8" METAL STUDS @ 16" D.C. W/ 5/8" GYPSUM BOARD ON BOTH SIDES. ***PROVIDE SOUND BATT. INSULATION AT RESTROOM & OFFICES WALL TYPE 2: NON -RATED WALL TO DECK - SECURED STORAGE W/ 3-518" METAL STUDS @ 16" O.C. W/ 5/8" GYPSUM 2 - BOARD ON BOTH SIDES. METAL SECURITY MESH (3/4" 9GA. )TO BE INSTALLED BETWEEN STUD/GWB ON ONE SIDE OF PARTITION 1 07-31-18 PERMITCOMMENTS NO. DATE REMARKS I REVISIONS DRAWING TITLE: CONSTRUCTION PLAN & DEMOLITION PLAN 51394.64 05-23-18 DRAWN BY: CHECKED BY: AC KN SHEET NUMBER: A1.01 E I PARTITION TYPES i CR2 exlr J. ---- -- 1 as d eH CK& ILL J� �113 112 — SECURITY r7 z .. 13 0 SALES R R [R�IR / "44" B11 U 1so 0 3 -F2 eoH �� p� cFc� LT 4] � a PANTRY � 6 3 0" ° No", �� - � � 1 -- - 3— C— �S.�� J �8'-7" A_ 11A i aa,� Ts 1 114 �0 °„ F2 -F2 RO.S. Ts`� TECH CL 7� F2 F2 LJJr, rtF R 7 A� 110 EC _F2 110 F2 _ Ow Vh ° , JJ s -- �L i v..,- 4 j a r 4 5 _ r12'- 8' 1' B _ J, — F2 F2 �F2 _ F2 I� 77 3)r T.e F2 A7.0) EQ 0 RETAIL w 103 �2/ F2 EQ - F2 � h2 - F2- MFCH RETAIL09 103 ��� 102� � i- 37; d o -� _ _ 6,• F2 102� EQEQo F2F2 F2 � --- �� _ ,-...,- wF4 I F4 AVEC 08RIDOR 1 X11 E b F2 F2 F2 d 0F F2 �CR 8'0" VIF 5ALE5 `• F2 F2 2 ° ° EQ� Q r,, 1 ��RI Ta 6'-2„ F3 A2.01) C �2 T E \� „i r F1 �� 106 8' - 7 a��F5 �101 OFFICE CHECK -IN LIVING RM CONSULTING wI _ P 1107 104 F2 F2 100 F2 F2 `Jd Q)F5 F2 01 - 107 j w c3 104 100 10 105 - F1 A) exiT ._ O CjW �'F5 _ - -- CJ 7 RESTROOM LT as 8L_-7 F1' F3 — R B� dl � ((`JMEREE.om �61 ram' �7�T1O 1058 7�A' sA�es' ! qi � 3 _. 3 }�J.' — -- — �--� -- ----- - — - — s J a—�— set ir—�I [ �f 1', , it � c 0 LE i 0 ilk 1 REFLECTED CEILING PLAN 1/8" = 1'-011-27POWER & COMMUNICATIONS PLAN 1/8" = 1'-0" SYMBOL DESCRIPTION MANUFACTURER COMMENTS SYMBOL DESCRIPTION COMMENTS TYPE "A" - NEW _ - _ - -- - - T i UNDER COUNTER REFRIGERATOR. MANUF: MARVEL, 24" LOW 2X2 ACOUSTICAL TILE CEILING SYSTEM PROFILE BEVERAGE REFRIGERATOR. STYLE: OVERLAY GLASS 2X2 RECESSED PHILIPS DAY-BRITE CFI OR APPROVED EQUAL - SEE M.E.P. } WALL MOUNTED DUPLEX OUTLET RIGHT -HINGED. FINISH: STAINLESS F1 FLUORESCENT SP TROFFER 2X2 T8 DOCUMENTS FOR MORE INFO DUNE 1772 TILE & GRID -- - _ _ -- - -- LIGHT FIXTURE CONTACT: BRITTANY DYTRYCH 708.341.8905 DEDICATED WALL MOUNTED DUPLEX OUTLET C = COPIER POWER - GC TO VERIFY NEMA PLUG _ T z " COFFEE MAKER -MANUF. &MODEL: TBD CONTACT: BRITTANY DYTRYCH 708 INTENSE#SS4G3DR-L1-358-L100/IC430H2-SFW OR APPROVED EQUAL - SEE M.E.P. WALL MOUNTED QUADRUPLEX OUTLET 4" ROUND RECESSED TYPE "B- N BOARD ON DRYWALL EW F2 O LED LIGHT FIXTURE .341.8905 DOCUMENTS FOR MORE INFO SUSPENSION SYSTEM /METAL STUD FLOOR MOUNTED POWER! DATA TELEPHONE OUTLET PROVIDE (1) DUPLEX (1) SHARED CLEAN GRIND (1) DATA Ta HI-LO DRINKING FOUNTAIN. REFER TO ELEVATIONS AND (1) VOICE - PER DECIVE MOUNTING HEIGHTS DIAGRAM FRAMING - REFER TO FINISH SCHEDULE ROUND RECESSED WALL INTENSE 3.5" MX G2 LED SQ. ADJ. MXG2ASTR OR APPROVED EQUAL - SEE M.E.P. ra F3 9 CONTACT: BRITTANY DYTRYCH 708.341.8905 DOCUMENTS FOR MORE INFO FOR PAINT COLOR WALL MOUNTED POWER /DATA /TELEPHONE OUTLET _ Y _ L BOH UNDER COUNTER REFRIGERATOR. MANUF: SUMMIT, AL54 WASHER LIGHT FIXTURE TYPE "C" -OPEN TO ABOVE - BUILT IN. FINISH: STAINLESS STEEL DOOR. *OR APPROVED T WALL MOUNTED TELEPHONE OUTLET EQUAL QTRAN #IQ20-35-20-90-5.0 OR APPROVED EQUAL - SEE M.E.P. WALL MOUNTED DATA OUTLET F4 _ _ _ LED STRIP LIGHT FIXTURE CONTACT: BRITTANY DYTRYCH 708,341.8905 DOCUMENTS FOR MORE INFO 1 Ts MICROWAVE. MANUF: GE COUNTERTOP MICROWAVE. MODEL: WALL MOUNTED POWER / DATA WHIP PROVIDE (1) DUPLEX (1) AND (1) DATA AT EACH POS STATION JES1145SH FINISH: STAINLESS BESA LIGHTING'RONDO' 12V MINI PENDANT CEILING CEILING HEIGHT FROM A.F.F. - - - T.s SECURITY EQUIPMENT- MONITORS BRONZE FINISH W/ C U SYMBOL F5 PENDANT LIGHT FIXTURE CHAMPAGNE REFLECTOR u-0' i CR CARD READER --- - - - -- - --- - __ -- CONTACT: BRITTANY DYTRYCH 708.341.8905 CEILING TYPE - WALL MOUNTED DEVICE: BACK BOX CONDUIT FOR TELEVISION GC & COMMUNICATIONS VENDOR TO COORDINATE DATA TV) T 7 DESKTOP PRINTER - REQUIREMENTS W/ TENANT PLAN - F6 PENDANT LIGHT FIXTURE TBD =� C CEILING TYPE LEGEND A POWER AND COMMUNICATIONS LEGEND [THe POS EQUIPMENT rs WALL MOUNTED SWITCH ATM MACHINE _ A2.011 PROVIDE PRICE ALTERNATE: EXISTING CEILING GRID TO BE J CARD READER BY OTHERS (PROXIMITY CARD ACCESS ONLY, THIS LOCATION) REFER TO SECURITY —= )PROVIDE PROVIDE NEW TO MATCH EXISTING WHERE VENDOR DRAWINGS T iC WALL MOUNTED TV JUNCTION BOX FOR CONFIRM W/ SECURITY VENDOR REQUIRED. EXISTING CEILING TILE TO BE DEMOLISHED. `2; CARD READER BY OTHERS (PIN ACCESS ONLY, THIS LOCATION) REFER TO SECURITY VENDOR DRAWINGS \J DRAWINGS / CAMERA EQUIPMENT ( 3 ALL SECURITY REQUIREMENTS TO BE CONFIRMED WITH OWNER 4 PROVIDE 4'X PHONE BOARD. QUAD ON DEDICATED 20 AMP CIRCUIT E EXISTING FIXTURE TO REMAIN �C5 1 DATA RACK BY OTHERS R RELOCATED FIXTURE 6 i BACK OF HOUSE SINK AND FAUCET, REFER TO MEP DOCUMENTS ✓) REMOVE EXISTING POWER @ EXISTING PARTITION ONLY WHERE NOTED ax CONTRACTOR PROVIDED }} ly CEILING MOUNTED DUPLEX T 8; REMOVE EXISTING 72" JBOX @THIS LOCATION [Tx I TENANT PROVIDED /CONTRACTOR INSTALLED POWER & DATA OUTLET A LIGHT FIXTURE SCHEDULE D ALTERNATES B POWER AND COMMUNICATIONS PLAN KEYNOTES D EQUIPMENT LIST 1. ALL OUTLETS IN OFFICES TO BE CENTERED WITHIN GANGED OUTLETS. CENTER OUTLETS OM WALL UNLESS OTHERWISE 4.0 GENERAL REQUIREMENTS 0 PEAKED CEILING - EXISTING TO REMAIN. WOOD FINISH AND DIMENSIONED OR NOTED TRIM TO REMAIN. GC TO REPAIR AND REFINISH AS REQ 2. SWITCHES, FIRE DEVICES, ETC. SHALL BE GANGED AND LOCATED PER MOUNTING DIAGRAM SPECIFICATIONS. 4.0.1 REFER TO PARTITION PLAN FOR TYPICAL GENERAL 2.0 GENERAL REQUIREMENTS 2.2 COORDINATION ACCESS: 3. ALL OUTLETS MOUNTED ABOVE COUNTER SURFACES, ARE TO BE MOUNTED HORIZONTALLY. REQUIREMENTS INCLUDING SUBMITTALREQUIREMENTS. 2.0.1 REFER TO PARTITION PLAN FOR TYPICAL GENERAL 2.2.1 ACCESS SHALL BE PROVIDED BY GC AS REQUIRED FOR -� 4. GC & EC TO REFER TO AV DOCUMENTS & COORDINATE WALK THRU W/AV CONSULTANT FOR EXACT PLACEMENT OF 4.1 REQUIREMENTS INCLUDING SUBMITTAL REQUIREMENTS. INSTALLATION AND MAINTENANCE OF MECHANICAL, ELECTRICAL, (2� RECESSED FIXTURES AT TRELLIS TO BE COORDINATED WITH POWER/TELE/DATA OUTLETS, SPEAKERS AND CONDUITS. REFER TO AV DRAWINGS FOR SPECIFIC REQUIREMENTS. ARCHITECTURAL GENERAL POWER AND COMMUNICATION NOTES: DATA AND OTHER ELEMENTS WITHIN CEILING PLENUM AND AS TRELLIS OPENINGS / LOCATION DRAWINGS ARE FOR INFORMATION PURPOSES ONLY. 2.1 GENERAL CEILING NOTES: REQUIRED BY CODE. THIS ACCESS SHALL BE REVIEWED WITH THE 5. ALL OCCUPANCY SENSORS TO BE TIMED AT 10 MINUTE INACTIVITY U.N.O. AND TO BE FINE-TUNED WITH TENANT DURING FINAL 4.1.1 REFER TO GENERAL POWER AND COMMUNICATION 2.1.1 REFER TO GENERAL REFLECTED CEILING STANDARDS FOR BASE BUILDING ENGINEER TO CONFIRM SUITABILITY FOR GENERAL 3 CEILING MOUNTED POWER FOR SPEAKERS CLOSEOUT STANDARDS FOR TYPICAL INFORMATION. TYPICAL INFORMATION. MAINTENANCE. 2.1.2 INSPECTIONS AS REQUIRED BY LOCAL AUTHORITIES SHALL BE 2.2.2 LOCATIONS FOR SPECIAL ACCESS DOORS. HATCHES SHALL BE COMPLETED PRIOR TO CLOSING OF CEILING. COORDINATED WITH OTHER TRADES AND APPROVED BY THE LEGEND NOTES: 4.1.2 INSPECTIONS AS REQUIRED BY LOCAL AUTHORITIES SHALL BE 2.1.3 CEILING PLANE SHALL BE LEVEL AND TRUE AND ALIGN WITH ARCHITECT. ELECTRICAL, MECHANICAL SYSTEMS AND VALVES ETC.. ALL LIGHTS, SPRINKLER, HVAC AND OTHER ELEMENTS REQUIRING ACCESS ABOVE GWB OR HARD CEILINGS SHALL BE CEILING MOUNTED POWER &DATA FOR PEOPLE COUNTER - "GFI" WITH ANY OUTLET INDICATES THAT THE OUTLET IS A GROUND FAULT INTERRUPT OUTLET. COMPLETED PRIOR TO CLOSING OF CEILING OF ANY WALLS INCORPORATED IN ITS CONSTRUCTION. MOVED TO A SUITABLE LOCATION IDENTIFIED BY THE ARCHITECT PROVIDED AND INSTALLED BY OTHERS ANY OUTLET WITHOUT A LETTER OR SHOWN WITH AN 'IN" INDICATES THAT THE OUTLET IS NEW. OR CEILINGS. 2.1.4 FASCIAS / SOFFITS SHALL BE LEVEL AND TRUE, FREE OF SO THAT ACCESS HATCHES ARE NOT REQUIRED. "E" WITH ANY OUTLET INDICATES THAT THE OUTLET IS EXISTING TO REMAIN. SURFACE DISTORTION AND DIMENSIONED ACCORDING TO DETAILS "D" REMOVE, PATCH & REPAIR TO MATCH EXISTING ADJACENT FIXTURES 4.1.3 REFER SHOWN. 2.2.3 PROVIDE LINED "Z" BOOTS AT ALL TRANSFER DUCTS AND REQUIREMENTS TO REFLECTED CEILING PLAN FOR NOTES REGARDING 2.1.5 MECHANICAL, HVAC AND PLUMBING ELEMENTS SHALL AT NO WHERE RETURN VENTILATION IS REQUIRED AT FULL HEIGHT ALL DEVICES AND COVERPLATES TO BE WHITE U.N.O. 4.1.4 FIELD VERIFICATIONS: G.C. AND SUBCONTRACTORS SHALL BE TIME COME IN CONTACT WITH CEILING CONSTRUCTION EXCEPT AS PARTITIONS. WOOD WALLS TO RECIEVE BLACK DEVICE & COVER PLATES RESPONSIBLE TO VERIFY FIELD CONDITIONS AND NECESSARY PENETRATIONS MAY REQUIRE. 2.2A MECHANICAL AND ELECTRICAL CONTRACTOR SHALL 2.1.6 DIMENSIONS: COORDINATE WORK BETWEEN THE ENGINEERING AND THE E REFLECTED CEILING PLAN KEYNOTES REFER TO "MOUNTING HEIGHTS" ON SHEET A-0 FOR TYPICAL MOUNTING LOCATIONS AND HEIGHTS OF OUTLETS AND SWITCHES. DIMENSIONS BEFORE BEGINNING WORK. SIZES OF CONDUI ADEQUATE FOR CABLE/SERVICE SPECIFIED. REFER TO A. SCALES AS STATED ARE VALID ON THE ORIGINAL DRAWING ARCHITECTURAL DRAWINGS: ONLY. DO NOT SCALE FROM THESE DRAWINGS. WRITTEN ARCHITECTURAL CEILING PLAN SHALL GOVERN WITH RESPECT TO R-ALIGNISCHEDULED 4.1.5 COORDINATION OF ELECTRICAL WORK WITH HVAC, CABINET DIMENSIONS TAKE PRECEDENCE OVER GRAPHIC PRESENTATION. AESTHETIC CONSIDERATIONS, QUANTITY, LOCATIONS FOR WHEN LOCATELL OENOEs 1. ALL ACCESS PANELS SHALL BE LOCATED BY ARCHITECT. w"` WORK, CAR ASSURED BY GC. DETAIL DIMENSIONS TAKE PRECEDENCE OVER PLAN DIMENSIONS. FIXTURES, DEVICES ETC. CONTRACTOR SHALL BE RESPONSIBLE WHEN TOOEmER ANY AREAS REQUIRING ACCESS IN GWB CEILING SHALL BE B. NOTIFY ARCHITECT OF ANY DIMENSIONAL DISCREPANCIES, ANY FOR VERIFICATION OF QUANTITIES (NEW OR EXISTING) INDICATED I -, PHONE ViSUALALARM NOTED TO ARCHITECT PRIOR TO FINAL PRICING. --- EO Eo EncE of 4.1.6 ELECTRICAL CONTRACTOR TO PROVIDE FINAL CONNECTION MODIFICATIONS OR DEVIATION TO BE BROUGHT TO THE ON PLANS. OR ATTENTION OF THE ARCHITECT FOR REVIEW AND APPROVAL. MECHANICAL AND ELECTRICAL CEILING PLAN SHALL GOVERN WITH TOP OF COUNTER/ COAT OATHOOKE AFTER ALL FURNITURE HAS BEEN INSTALLED. SPLASH _ --- COAT HOOK AT OUTLEMOUNT D COUNTER OFFICE OF C. LIGHTS SHOWN IN 2x2 CEILING TILES SHALL BE CENTERED RESPECT TO FUNCTIONAL CONSIDERATIONS AND OVERALL SCOPE ( ) " MouNTeoHoarzorvTB OEEiCEDOORs 4.1.7 ALL TELE/DATA DROPS ARE INDICATED FOR INFORMATION EXIT FIXTURE -ARROWS WHERE PRESENT INDICATE o a U.N.O. OF WORK. ' — — THERMosTnT DIRECTIONAL INFORMATION LIGHT SWITCH ONLY. GC & EC TO COORDINATE W/ CABLE D. CONTRACTOR TO COORDINATE WITH ARCHITECT IF ANY r► ° o VENDOR'S DOCUMENTS OR W! TENANT TO CONFIRM FINAL LOCATION OF LIGHT FIXTURES OR DEVICES ARE NOT SHOWN 2.3 LAMPING / SWITCHING: MAXDOOR LEVER SCOPE REQUIREMENTS. o DIMENSIONALLY PRIOR TO INSTALLATION. 2.3.1 WHEN ENGINEERING DOCUMENTS DO NOT EXIST: m n LL ° O ALL DOWNLIGHTS (INCANDESCENT OR LOW VOLTAGE) SHALL BE ON v ° / - mD ° FEE o -- cARDREaDER INDICATED ON DETAILS OR PLAN. ALL WALL WASHERS SHALL BE ON DIMMERS PER ARCHITECT'S wGED ourLETs 2.1.7 PROVIDE SEMI -RIGID SOUND ATTENUATION BLANKETS A SINGLE DIMMER RESPECTIVELY. 2.1.8 CONTRACTOR SHALL VERIFY WITH BUILDING MANAGEMENT IF INSTRUCTION. H ENERGY MANAGEMENT SYSTEM IS IN USE AND IF TENANT CONSULT WITH ARCHITECT FOR QUANTITY IN A GIVEN ROOM. SYSTEMS ARE REQUIRED TO BE TIED INTO SAID MANAGEMENT ALL OFFICES SHALL BE SWITCHED INDEPENDENTLY. NOTE: ALL DIMENSIONS SHALL MEET LOCAL ACCESSIBILITY CODE MATCH EXIST. HEIGHTS WHERE SYSTEM. THIS WORK SHALL BE PART OF THE OVERALL CONTRACT ALL CORRIDOR SHALL BE ON A TIMED SWITCH BANK PER POSSIBLE. CONTACT A.S.D. WITH ANY QUESTIONS OR CONFLICTS RE. MOUNTING HEIGHTS. IF REQUIRED. QLIADRANT IN A LOCATION COORDINATED BY THE ARCHITECT. B REFLECTED CEILING PLAN GENERAL NOTES F REFLECTED CEILING PLAN STANDARDS C I GENERAL POWER AND COMMUNICATIONS PLAN TYPICALS E POWER AND COMMUNICATIONS PLAN GENERALNOTES 1240 East 5th Avenue Tampa, FL 33605 T 813.223,2293 F 813.223.2433 www,asdsky.com J U`^) vJ LO u7 1 co W EC_ U tf ,) W (/5 00 ryg CO 4 Y Q lt � � M N y � � 4 Q mOL d d This drawing is the property of Associa Space Design, Inc. and is not to be reproduced or copied in whole or part. not to be used on any other project and be returned upon request. Scales as ste herein are for reference only as norm; reproduction processes may alter thi accuracy of original drawings. Associated Space Design, Inc. 2018 NO: DATE: REMARKS, REVISIONS, REFLECTED CEILING PLAN & POWER & COMMUNICATIONS PLE ROJECT NO.: ISSUE DATE: 51394.64 05-23-18 RAWN BY: CHECKED BY: AC KN HEET NUMBER: A2.01 13-16 CORRIDOR L oaa e 1, . r �1 f ors'' H ' 4 t 1 MAWEfPLACE 1 r �lli� 1--------- t \ lI, {`4 "S4 3 In I' m77 t � I ♦ � n li_fi'r''t --------------/_—.\J a _ 0110 il M. 0=0 33-36 `'" p 41- 4tir O SHELVIRG 29-32 M PxemL�msNaw* 52 * • — f f I 9 1 1-24 1 `� t � ---ice - 4--4 I I E Y6 gtl I B r ' 49-50 I i � _ 6-10--------------OJ O O i—i 1 2-5 1 EIEI L OF_=O WAKETPLst.E SNEINNO --------------------- i�1 fr,�,j 4 MrM.00 r_-__-----....-J IBM I 71� 11 . d A O O I I \\ O �❑ Pli 2A L_ - _ �t win 1 SECURITY PLANS - FOR REFERENCE ONLY ­.." EXTERIOR CAMERAS: 8 AXIS M3024-LVE INTERIOR CAMERAS: 10 AXIS M3105-L 360 CAMERAS: 2 AXIS M3047-P HEIGHT STRIP CAMERAS: 1 AXIS P8535 INTERCOM CAMERA: 1 AXIS A8105-E PUSH BAR REQUEST TO EXIT: 1 ELECTRIC STRIKES: 2 DOOR POSITION SENSORS: 5 CARD READER: 3 CARD READER W/KEYPAD: 1 PANIC BUTTONS: 4 MOTION SENSORS: 3 ALARM SIREN: 1 SAFE SENSOR: 1 KEYPAD: 1 NETWORK DROPS: 52 *SEE ATTACHED BREAKDOWN WIRELESS ACCESS POINT: 1 TRAFSYS: 1 SONOS SPEAKERS: 1 50 IN TV: 1 37 IN TV: 2 NETWORK DROPS 1 TRAFSYS (1X1) 2-10 CHECK -IN (2X4) 11-12 ALCOVE "ATM" (1X2) 13-16 CONSULT (1X4) 17-32 POS (4X4) 33-44 PACK N FILL (3X4) 45-48 SECURE PANTRY (1X4) 49-50 KITCHEN (1X2) 51 WAP (1X1) 52 SONOS (1X1) 2 1 SECURITY PLAN LEGEND GENERAL INFORMATION: ALL NETWORK CABLE WILL BE CAT 5E, PLENUM RATED, WHITE. CABLE SHALL BE RUN IN ACCORDANCE WITH LOCAL CODES. EACH END WILL BE TERMINATED INTO A PUNCH DOWN KEYSTONE INSERT APPROPRIATE FOR THE PATCH PANEL OR DEVICE CONNECTION. CABLE RUN ABOVE CEILING CAN BE "FREE WIRED", WITHOUT CONDUIT AS LONG AS IT IS APPROPRIATELY SUPPORTED AND NOT LAYING ON THE CEILING TILES. IN WALL CABLE WILL BE RUN IN CONDUIT TO THE LOCATIONS SPECIFIED BELOW. CONDUIT, BOXES AND CONDUIT RELATED MATERIALS TO BE PROVIDED AND INSTALLED BY THE ELECTRICIAN AS SHOWN ON PLANS. ALL BOXES USED FOR CONDUIT RUNS AND NETWORK CABLE TERMINATION WILL BE STANDARD 1900 BOXES. ALL BOXES WHERE NETWORK JACK PLATES WILL BE INSTALLED WILL HAVE A SINGLE GANG MUD RING INSTALLED BEFORE THE SHEET ROCK IS INSTALLED. DEVICE CONNECTION PLATES ARE SINGLE GANG WITH OPTIONS FOR ONE, TWO OR FOUR KEYSTONE INSERTS. THESE PLATES WILL BE INSTALLED BY LOW VOLTAGE CONTRACTOR ON ELECTRICAL BOXES INSTALLED BY THE ELECTRICIAN. NETWORK AND LOW VOLTAGE WIRING MUST BE RUN IN A SEPARATE CONDUIT FROM HIGH VOLTAGE WIRING. WHERE REQUIRED BY LOCAL CODE, ANY CABLING BELOW GRADE MUST BE RATED FOR DIRECT BURIAL EVEN IF RUN IN CONDUIT. ALL NETWORK CABLING WILL BE TERMINATED TO TIA/EIA 568B, ALL NETWORK CABLING WILL BE NUMBERED ON BOTH END AS SHOWN ON THE PLANS USING A STANDARDIZED NOMENCLATURE: DATA (D-_J, WIRELESS ACCESS POINT (WAP-_), TRAFSYS, PEOPLE COUNTER (TS-_), CAMERA (C---), HOLDUP BUTTON (HUB - SECURITY DEVICE (S--). SURTERRA DEVICE LOCATION SPECIFICS: SONOS SPEAKERS EACH SPEAKER WILL BE CONNECTED TO A SINGLE NETWORK JACK. THIS JACK WILL BE WALL MOUNTED, TOP OF BOX, AT 18" BELOW CEILING HEIGHT. IN ADDITION, EACH SPEAKER WILL PLUG INTO A DUPLEX OUTLET INSTALLED BESIDE THE NETWORK JACK. IF WALL MOUNT ELECTRICAL OR LOW VOLTAGE TERMINATION IS NOT AVAILABLE OR POSSIBLE A CEILING TILE ELECTRICAL AND NETWORK INSTALLATION IS ACCEPTABLE IF WITHIN LOCAL CODE. TELEVISIONS: • EACH TV WILL BE CONNECTED TO A SINGLE NETWORK JACK. • THIS JACK WILL BE MOUNTED 60" AFF, CENTERED BEHIND THE TV AS SHOWN ON THE PLANS. IN ADDITION, EACH TV WILL PLUG INTO A DUPLEX OUTLET INSTALLED BESIDE THE NETWORK JACK. SECURITY MONITOR: A TV WILL BE MOUNTED IN THE BACK (RESTRICTED ACCESS) WORKING AREA OF THE FACILITY. THIS JACK WILL BE MOUNTED 48" DOWN FROM THE CEILING, CENTERED BEHIND THE TV AS SHOWN ON THE PLANS. IN ADDITION, EACH TV WILL PLUG INTO A DUPLEX OUTLET INSTALLED BESIDE THE NETWORK JACK. THIS WILL HAVE A HDMI CABLE RUN FROM THE NVR TO THE TV. WORK STATIONS: WORK STATIONS LOCATED AT THE POS DESK, CHECK IN DESK AND, SECURITY DESK WILL NEED 4 NETWORK JACKS EACH. A SINGLE GANG, FOUR PORT PLATE WILL ACCEPT 4 KEYSTONE INSERT AND BE MOUNTED TO A SINGLE GANG MUD RING FOR EACH WORK STATION. THE SINGLE GANG PLATE WILL BE FLOOR MOUNTED BELOW THE CHECK IN AND POS DESKS IF THE FURNITURE FIXTURE DOES NOT CONNECT TO A WALL. THE SINGLE GANG PLATE WILL BE WALL MOUNTED UNDERNEATH THE DESKTOP AT THE LOCATION SHOWN ON THE PLANS FOR ANY DESK LOCATED IN AN OFFICE OR BACK OF HOUSE. THE BOTTOM OF THE SINGLE GANG PLATE WILL BE 12" AFF. PEOPLE COUNTER: THE PEOPLE COUNTER WILL BE CONNECTED TO A SINGLE NETWORK JACK. A SINGLE GANG, ONE PORT PLATE, WILL ACCEPT THE ONE KEYSTONE INSERT AND BE CEILING MOUNTED WHERE SHOWN ON THE PLANS. A STANDARD SINGLE GANG BOX WITH A MUD RING AND THE NETWORK CABLE SHALL BE TERMINATED WITH A MALE TERMINAL TO PLUF DIRECTLY INTO THE DEVICE. WIRELESS ACCESS POINT: THE WAP WILL BE CONNECTED TO A SINGLE NETWORK JACK. A SINGLE GANG, ONE PORT PLATE, WILL ACCEPT THE ONE KEYSTONE INSERT AND BE CEILING MOUNTED WHERE SHOWN ON THE PLANS. A STANDARD SINGLE GANG BOX WITH A MUD RING AND THE NETWORK CABLE SHALL BE TERMINATED WITH A MALE TERMINAL TO PLUF DIRECTLY INTO THE DEVICE, NETWORK RACK SPECIFICS: THE NETWORK RACK WILL MOUNT TO A 4'X8'X3/4" PLYWOOD BOARD MOUNTED AS INDICATED ON THE PLANS. THE NETWORK RACK SHOULD MOUNT ON THE BOARD AND 12" BELOW THE CEILING. NETWORK RACK SHALL BE SWING OUT EQUIPPED, MIN 12U HEIGHT (15 PREF), TAPPED MOUNTING HARDWARE (NO CAGE NUTS), USABLE INTERNAL DEPTH OF 18" OR GREATER (23" PREF), LOCKABLE SIDE PANELS, AND LOCKABLE GLASS FRONT DOOR PANEL. EQUIPMENT TO BE MOUNTED IN THE RACK: 1 SHELF FOR THE VOIP PHONE SERVER AND NETWORK SECURITY APPLIANCE (2U) NETWORK SWITCH (2U) PATCH PANEL (2U) NVR (2U) UPS (RACK MOUNT, 1500VA OR HIGHER) (2U) A QUAD ELECTRICAL OUTLET ON A DEDICATED 20 AMP CIRCUIT WILL BE MOUNTED ON THE PLYWOOD BOARD BELOW THE NETWORK RACK. A GROUNDING BLOCK SHALL BE INSTALLED. SECURITY PANEL AND HARDWARE: ALL ACCESS CONTROL, FIRE, AND BURGLARY HARDWARE SHALL BE MOUNTED WITH THE NETWORK RACK ON THE SAME WALL. THE ACCESS CONTROL, FIRE, AND BURGLARY HARDWARE SHALL BE CONNECTED TO A UPS THAT IS WALL MOUNTED AND DEDICATED TO THOSE DEVICES WITH A RATING OF 850VA OR HIGHER. EXTERIOR REAR DOORS SHALL HAVE NO EXTERIOR EXPOSED OR VISIBLE HARDWARE. ACCESS CONTROL SHALL BE USED WITH AN EXTERNAL HID PROX CARD II READER MOUNTED EXTERNALLY THE INTERNAL DOOR CONTROL SHALL BE A PUSH BAR SYTEM. INTERNAL DOOR ACCESS CONTROL POINTS MAY HAVE FRAME. MOUNTED LATCH ACTUATORS. ALL ACCESS CONTROL POINTS SHALL BE CONFIGURED TO REMAIN IN A LOCKED POSITION IN CASE OF POWER LOSS. 3 1 SECURITY PLAN GENERAL NOTES if AUG 17 20a Permfitting De Stpartment Lucie co FL ASD SK 1240 East 5th Avenue Tampa, FL 33605 T 813.223.2293 F 813.223.2433 www.asdsky.com Florida Business License #: AA2601 Registered Architect: Kennet Registered Architect License #: AR932 This drawing is the property of Ass Space Design, Inc. and is not tc reproduced or copied in whole or p not to be used on any other project be returned upon request. Scales a: herein are for reference only as n reproduction processes may alte accuracy of original drawing: Associated Space Design, Inc. , NO, DATE REMARKS REVISIONS TLE: SECURITY PLAN 51394.64 05-23• DRAWN BY: CHECKED BY: AC KN SHEET NUMBER: A3.01 ASD SKY 1240 East 5th Avenue Tampa, FL 33605 T 813.223.2293 F 813.223.2433 www.asdsky.com _4�SURJERRA WELLNESS PAK &FILL SECURITY PACK & FILL SECURITY 113 ��— — — 112 �3 CJ F112 — — �� PT-� °s BOH � B-s 'I'll BOHB3 — — _ SECURE- 1C0) -SECURE PANTRY / — T — — PANTRY 114 114 ttl TECH CLB P.O.S. / P.O.S. I -i T I 7 B 1� � MECH RETAIL— 11 0 109 ;"RETAIL cPTI cPT1 MECH oSQ RETAIL — GARDEN FT-1 103 RETAIL r a 6 109 -- 103 102 VCT_I-7 h_I 83 — GARDEN`4. I — o J I� CORRIDORi3 / CORRIDOR �/. DI B4 TABLE RISER Y ® U 108 DIRECTION OF 11 ALCOVE ALCOVE - FLOOR TILES U 106 P -i :3 T-1 106 � 5 OFFICE OFFICE CHECK -IN LIVINGRM CONSULTI G 1P07 PT CHECK-IN �' LIV�INGRM CONSULTING ' - (f� 04 107 Fa 104 1 1 100 5 101 5 T- B2 —7 RESTROOM O� 2 5 B 104 100 101 4 7 O B-i `- M �(J7 105 - ® O G J I� J cc 0 0 cc w �� .,, i n�7S i _r�l _r. o_c.—u rtS �U RESTROOM i U 105 I W 0 L� u 0 0 C LLJ 0 0 '' ^�m U) 0 VJ d 1 FURNITURE PLAN 1/8" = 1'-0" 2 FINISH PLAN 1/8" = 1'-0" Y 3.0 GENERAL REQUIREMENTS 9 KEY ITEM MANUFACTURER DESCRIPTION / STYLE I COLOR REMARKS 3.0.1 REFER TO PARTITION PLAN FOR TYPICAL GENERAL REQUIREMENTS INCLUDING iV REPRESENTATIVE 1O GC TO PROVIDE & INSTALL SCHLUTER QUADEC TILE EDGING AT END OF TILE RUNS AND SUBMITTAL REQUIREMENTS. J 1. FURNITURE PLAN FOR REFERENCE ONLY. CONTRACTOR TO TRANSITIONS r CLGA PAINT BENJAMIN MOORE WHITE DIAM ND 2121-60 GYP. BD. CEILINGS, EGGSHELL FINISH. 3.0 GENERAL FINISH NOTES: COORDINATE WITH CLIENT & FURNITURE VENDOR. FIELD m z n, TILE TO BE CENTERED IN ROOM AND CONTINUOUS FROM ROOM TO ROOM 3.1.0 REFER TO GENERAL FINISH STANDARDS FOR TYPICAL INFORMATION INCLUDING SUBMITTAL 6 VERIFY ALL MEASUREMENTS &CLEARANCES j a w REQUIREMENTS. U FURNITURE KEY PT-1 PAINT BENJAMIN MOORE WHITE DIAM ND 2121-60 EGGSHELL FINISH. 0' ALL NEW FINISHES TO COMPLY WITH FBC 803 AND FBC 804 - WOOD FINISHES OF ANY KIND TO BE 3.2.FLOOR: FIRE -RETARDANT TREATED 3.2.1 CONTRACTOR IS RESPONSIBLE FOR ALL FLASH PATCHING AND TO HAVE FLOOR IN CONDITION PT-2 PAINT BENJAMIN MOORE SILVER FOX 2108-50 EGGSHELL FINISH. TO RECEIVE MATERIALS PER PLAN. CONTRACTOR TO INSURE THAT DOOR CLEARANCES PER This drawing is the property of Associated !J LOUNGE CHAIR - SIZE SHOWN: 24"W X 33"D DETAILS ARE MET. Space Design, Inc. and is not to be ® PAINT NEW EXTERIOR PARTITION TO MATCH ADJACENT CONSTRUCTION 3.2.2 VCT INSTALLATION SHALL BE PER INSTRUCTIONS ON DRAWING. SEAMS SHALL BE TIGHT AND reproduced or copied in whole or part. It is PT-3 PAINT BENJAMIN MOORE IRON MOUNTAIN 2134-30 EGGSHELL FINISH. INVISIBLE. FLOOR SHALL BE CLEANED PER MANUFACTURERS INSTRUCTIONS AND RECEIVE TWO (2) not to be used on any other project and is to 2 SOFA - SIZE SHOWN: 89"W X 36"D LVT-2 LUXURY PARTERRE SIZE: 2 MM, 6"X36" PLANK WALLS AT P.O.S. COATS OF NON -SLIP WAX WHICH SHALL BE THOROUGHLY MACHINE BUFFED (AS APPROPRIATE TO be returned upon request. Scales as stated VINYL PLANK JENNIFER GERMUNDSEN TILE MANUFACTURER) COLOR: HAYSTACK OAK 11604 herein are for reference only as normal 727.455.5366 INSTALLATION: BRICK - 33% 3.2.3 CONTRACTOR SHALL PROVIDE VINYL TRANSITION STRIPS AND RUBBER TRANSITION STRIPS AT reproduction processes may alter the 3 DISPLAY TABLES PROVIDE BY OTHERS PATTERN: 3"X6" SUBWAY TILE ALL LOCATIONS REQUIRED. PROVIDE SAMPLE FOR COLOR PRIOR TO INSTALLATION. accuracy of original drawings. J WT-1 WALL TILE OLYMPIA TILE CONSULTING WALL. GC TO PROVIDE 3.3.0 WALLS:Associated Space Design, Inc. 2018 s. COLOLLATIO : B GREY ALPHA TILE &STONE INSTALLATION: BRICK - 50% & INSTALL "SCH OF TILE RUN " 3.3.1 PAINT FOR WALL FINISHES SHALL BE THREE 3 RYAN KEETCH 813.299.4088 GROUT: WHITE EDGING AT END OF TILE RUN ( ) COATS (EGGSHELL U.N.O. IN FINISH PLAN SIDE TABLE - SIZE SHOWN 16" DIAMETER __- _ STANDARDS); ONE W PRIMER PLUS TWO (2) FINISH COATS, COLOR MI SPECIFIED. METAL ELEMENTS J PATTERN: THE VALUE 99 AND DOOR /WINDOW FRAMES SHALL HAVE THREE (3) COATS OF SEMI -GLOSS LATEX ENAMEL FINISH. VINYL WOLF GORDON RESTROOM WET WALLS. � WC-1 3.3.2 G.C. SHALL ASSURE THAT NO ELECTRICAL RECEPTACLE OR TELECOMMUNICATIONS OUTLET O5 COUNTER STOOLS -HEIGHT OF SEAT TO BE COORDINATED WALLCOVERING LES COLE 813.786.0678 PRODUCT IQ: G 8617904 PRODUCT #: VB 42087 COVER PLATES HAVE BEEN INSTALLED PRIOR TO COMPLETION OF APPLICATION OF ANY WALL FINISH WITH ISLAND COUNTER HEIGHT -- — - - MATERIALS. ANY APPLIED COVER PLATES OR SURFACE HARDWARE ETC. SHALL BE REMOVED PRIOR T-1 FRONT OF THE HOUSE AND PORCELAIN OLYMPIA TILE PATTERN: REGAL TO FINAL WALL FINISH APPLICATION. © NOT USED TILE ALPHA TILE & STONE COLOR: SHELL WHITE, MATTE RESTROOMS. GROUT: MAPEI - 01 RYAN KEETCH 813.299.4088 SIZE: 6" X 24" ALABASTER 1/8" MAX, OR APPROVED 3.4.0 MISCELLANEOUS: INSTALLATION: BRICK - 33% EQUAL 3.4.1 ALL MISCELLANEOUS GRILLS, PLATES, ETC. OCCURRING ON WALLS OR CEILING SHALL BE O7 TASK CHAIR -- --- - - - PAINTED TO MATCH THE SURFACES ON WHICH THEY OCCUR U.N.O. ALL METAL SURFACES SHALL BE VCT-1 VINYL ARMSTRONG PATTERN: STRIATIONS BACK OF HOUSE PRIMED PRIOR TO PAINTING. COMPOSITE DAVID PRICE 813.285.6868 COLOR: T3603 TWILIGHT OS GUEST CHAIR - SIZE SHOWN: 24"WX22"D TILE SIZE: 12"X2 INSTALLATI N: BRICK Z O EMPLOYEE LOCKERS O 2CPT-1 CARPET TILE PATCRAFT PATTERN: D SRUPT 10385 RETAIL GARDEN WALLS PT-1 O GINA SCHIRO 813.244.1668 COLOR: FA RICATE 00320 BASE B-1 ILLSIZE: 24" X 2 - - 3 10) STORAGE SHELVES ___ ____ INSTALLATION: ASHLAR wA�B CARPET CPT-1 B-1 VINYL BASE JOHNSONITE SIZE: 4" THROUGHOUT � BBSS' ! STANDARD FINISH TAG. REFER TO FINISH SCHEDULE. CEILING CLG-1 CEILING WHITE BASE 3 STYLE: STRAIGHT COLOR: 08 ICICLE _- -- MULTIPLE FINISHES OCCUR AT SOME LOCATION. SEE REFERRING PLAN OR ELEVATION FOR DETAILS. 2. TYPICAL OFFICE FINISHES ARE AS NOTED: B-2 WOOD BASE MILLWORK SIZE: 4" STYLE: STRAIGHT LOGO WALL NO: DATE: REMARKS: COLOR: PT-3 wAu ACCENT WALL FINISH. Q B-3 VINYL BASE JOHNSONITE SIZE: 4" STYLE: STRAIGHT THROUGHOUT, COVE BASE AT REVISIONS: m COLOR: GATEWAY TA4 VCT FLOORING DRAWING TITLE: - -rooa ACCENT FLOOR MATERIAL. wnu, FURNITURE & FINISH PLA PLASTIC LAM. FORMICA 8844 - WR AGED ASH KITCHEN & SALES & CHECK IN <F ooa 800.367.6422 WOODBRUSH FINISH DESK SIDES AND FRONT BASE PLAN WALL PL-2 PLASTIC LAM. OCTOLAM BY OCTOPUS SLATE 161 POS BASE BASE MATERIAL. 877.628.6526 PROJECT NO,: ISSUE DATE: PL-3 PLASTIC LAM. ABET LAMINATI 1800.228.2238 847 SEI ISLAND BASE L. - —� 51394.64 05-23-18 FLOOR MATERIAL TRANSITION DRAWN BY: CHECKED BY'. PL-4 PLASTIC LAM. FORMICA 1 800.367,6422 949-58 WHITESECURITY & B.O.H. � AC KN SS-1 SOLID SURFACE CORIAN 1800.426.7426 ANTARTICA KITCHEN COUNTERTOP SHEET NUMBER: A FURNITURE PLAN GENERAL NOTES & g FINISH SCHEDULE: D FINISH SYMBOL LEGEND: E FINISH PLAN GENERAL NOTES A3.O2 , KEYNOTES 121 ELEVATION -OFFICE O OPEN N 2'- 0" 10 3/4" 2'-0" - - 7'- 0 1/4"" 10 ELEVATION -OFFICE HOLLOW METAL - FRAME CAT II SAFETY it GLASS PULL -DOUG — MOCKETT DP3,TYPICAL o (V 1 6'- 5 3/4" 2 _ 3 Z72� 7.02 A.02 OP N y I 1' - 3' =8 1 3/4" 2'-8" 2' - 0" 1V-03/4" 3/8" = V-0" 1 9 1 ELEVATION -OFFICE * ALL EXPOSSED SURFACES TO BE P. LAM P61 P.LAM COUNTERTOP W/ WATERFALL EDGE Pi PULLS - DOUG MOCKETT DP3 TYP 1-1/2" P-LAM 7 8 COUNTERTOP W/ A7.03 \AT WATERFALL EDGES 3/4" ADJ. SHELF SCHEDULED BASE P i V N 1-1/2" P-LAM COUNTERTOP W/ WATERFALL EDGES 1 1/2" T - 0" 1. 61, �1 T - 7 1" 1'- „ 1 1/2" 7 0 NOTE: ALL EXPOSED SURFACES TO BE P-LAM NOTE: ALL EXPOSED SURFACES TO BE P-LAM 3/8" = 1'-0" 7 1 ELEVATION - CHECK IN FRONT 3/8" = 1'-0" 3 1 ELEVATION - CHECK -IN REAR P.LAM COUNTERTOP P7 PROVIDE GROMMET AT BACK OF COUNTER VERTICAL SUPPORT SCHEDULED BASE 1-1/2" P-LAM COUNTERTOP W/ WATERFALL EDGES LOGO PROVIDED AND INSTALLED BY OWNER NOTE: ALL EXPOSED SURFACES TO BE P-LAM 3/8" = 1'-0" 6 1 ELEVATION - CHECK IN SIDE 3/8" = 1'-0" 2 1 ELEVATION CHECK IN CODE DESCRIPTION MANUF. MODEL FINISH STYLE REMARKS 1 PAPER TOWEL DISPENSER/ WASTE RECEPTACLE COMBINATION - SURFACE MOUNTED BOBRICK B-3949 STAINLESS CLASSIC SERIES REFER TO ELEVATIONS & DETAILS OF INSTALLATION LOCATIONS, HEIGHT & MFG'S MOUNTING DETAILS 2 SANITARY NAPKIN DISPOSAL - SURFACE MOUNTED BOBRICK B-254 STAINLESS CLASSIC SERIES REFER TO ELEVATIONS & DETAILS OF INSTALLATION LOCATIONS, HEIGHT & MFG'S MOUNTING DETAILS 3 TOILET TISSUE DISPENSER BOBRICK B-2888 STAINLESS CLASSIC SERIES INSTALL PER FLORIDA BUILDING CODE ACCESSIBILITY 4 A.D.A. GRAB BARS BOBRICK B-5806 X 36 & 5806 X 42 STAINLESS INSTALL PER FLORIDA BUILDING CODE ACCESSIBILITY 5 TOILET SEAT COVER DISPENSER BOBRICK B-221 STAINLESS CLASSIC SERIES REFER TO ELEVATIONS & DETAILS OF INSTALLATION LOCATIONS, HEIGHT & MFG'S MOUNTING DETAILS 6 FACE MOUNTED COAT HOOK BOBRICK B-2116 STAINLESS INSTALL PER FLORIDA BUILDING CODE ACCESSIBILITY 7A A.D.A. LAVATORY SINK - WALL MOUNTED EXISTING TO BE RELOCATED INSTALL PER FLORIDA BUILDING CODE ACCESSIBILITY 7B A.D.A. FAUCET KOHLER K-8761 FAUCET CHROME FAUCET INSTALL PER FLORIDA BUILDING CODE ACCESSIBILITY 8 A.D.A. COMPLIANT FIXED ANGLE TILT MIRROR BOBRICK B-293 1830 STAINLESS INSTALL PER FLORIDA BUILDING CODE ACCESSIBILITY 9 A.D.A. COMPLIANT SOAP DISPENSER - WALL MOUNTED BOBRICK B-2111 STAINLESS INSTALL PER FLORIDA BUILDING CODE ACCESSIBILITY 10 A.D.A. COMPLIANT HI-LO DRINKING FOUNTAIN ELKAY EHWM17C TBRUSHED S.S. INSTALL PER FLORIDA BUILDING CODE ACCESSIBILITY 11 A.D.A. COMPLIANT TOILET REFER TO MEP DOCUMENTS INSTALL PER FLORIDA BUILDING CODE ACCESSIBILITY Al PLUMBING FIXTURE / ACCESSORIES SCHEDULE '®J we-t SEE MOUNTING F 9 7B 21. 0" 1 SEE MOUNTING HEIGHT DIAGRAMS FOR HEIGHT DIAGRAMS FOR SPECIFIC MOUNTING SPECIFIC MOUNTING FOR ALL EQUIPMENT & FOR ALL EQUIPMENT & ACCESSORIES ACCESSORIES 7A n B3 B3 1 11 6" = 1'-0" ALIGN T-6" 110 CLEAR 0 U ou- a 1 ALCOVE O O 106 Lu — x ,I in 7 LU 5 1 ELEVATION - DRINKING FOUNTAIN/8" = 1'-0" SUiJERRA Af�\ FLLNES,, 5'-6" CHECK -IN LiOA- 7 ' ­ i d o 0 FriQ Q -v I j�� --------- ---- ------ RESTROOMSc0 105 SEE MOUNTING IEIGHT DIAGRAMS FOR T - 0 1/2" SPECIFIC MOUNTING -OR ALL EQUIPMENT & A6.01 / 4 ACCESSORIES I-� B3 1240 East 5th Avenue Tampa, FL 33605 T 813.223.2293 F 813.223.2433 www.asdsky.com -.4a U Rij WELLN 3/8" = 1'-0" �U J U) LO N rn M n- LL W L A/ J U) U) CD (0-1-- a s If 3/8 - 1 -011 � N Wo 1'<oo O� f— U n U � M < a � � M Mn v � N J d a a � a This drawing is the property of Associated Space Design, Inc. and is not to be reproduced or copied in whole or part. It is not to be used on any other project and is to be returned upon request. Scales as stated herein are for reference only as normal reproduction processes may alter the accuracy of original drawings. Associated Space Design, Inc. 2018 N0: DATE: REMARKS: REVISIONS: RAWING TITLE: INTERIOR ELEVATIONS & ENLARGED PLANS 51394.64 05-23-18 Ts CHECKED BY. AC KN 11 ELEVATION - RESTROOM 3/8" = 1'-0" 8 ELEVATION - RESTR60M 3/8" = 1'-0" 4 ELEVATION - RESTROOM 3/8" = 1'-0" 1 CONSTRUCTION PLAN - RESTROOM & CHECK IN 1/2" = 1'-0" NUMBER: A6.01 SOFFIT LVT FINISH - SEE 61A6.02 PULL -DOUG MOCKETT DP3, TYP. P.LAM COUNTERTOP TILL DRAWER PROVIDED AND INSTALLED BY OTHERS P.LAM BASE CABINET & SHELVING PL-z 10 I ELEVATION - POS STAFF SIDE PULL - DOUG MOCKE DP3, TYP. P.LAM COUNTERTOP PL.1 SOFFIT ALIGN WALL FINISH W/ FACE OF COUTNER 0 co LUXURY VINYL PLANKS TO BE INSTALL PATTERN TO ASHLAR PATTERN, 33% STAGGERED. ADHERE TO DRYWALL PER ATTACHED MANUFACTURERS INSTRUCTIONS. PLANKS WITH DIFFERENT GRAINING PATTERNS TO BE RUN TOGETHER (AS INDICATED BY HATCH) IF TWO LIKE GRAINING PATTERNS MUST BE NEXT TO EACH OTHER, FLIP BOARD TO DIFFERENTIATE (INDICATED BY ARROWS). OVERALL PATTERN SHOULD BE VARIED FOR NATURAL EFFECT. HATCHES AND ARROWS ARE FOR DIAGRAMMATIC PURPOSE. " = T-0" 6 ELEVATION POS - BACK LVT 1 3/8" = 1'-0" 2 ELEVATION POS - BACK TILL DRAWER PROVIDED AND INSTALLED BY OTHERS P.LAM BASE CABINET & SHELVING PL-z 9 I ELEVATION - POS STAFF SIDE 6 \ � 5 7.03 \A7 �1'-21/2� MIN 11 l MIN MIN 11 MIN 11 8 I ELEVATION - POS STAFF SIDE 7 I ELEVATION - POS CUST. SIDE SOFFIT ALIGN WALL FINISH W/ FACE OF COUNTER LUXURY VINYL PLANKS TO BE INSTALL PATTERN TO ASHLAR PATTERN, 33% STAGGERED. ADHERE TO DRYWALL PER ATTACHED MANUFACTURERS INSTRUCTIONS. PLANKS WITH DIFFERENT GRAINING PATTERNS TO BE RUN TOGETHER (AS INDICATED BY HATCH) IF TWO LIKE GRAINING PATTERNS MUST BE NEXT TO EACH OTHER, FLIP BOARD TO DIFFERENTIATE (INDICATED BY ARROWS). OVERALL PATTERN SHOULD BE VARIED FOR NATURAL EFFECT. HATCHES AND ARROWS ARE FOR DIAGRAMMATIC PURPOSE. = 1'-0" 5 ELEVATION POS - BACK LVT 2 3/8" = 1'-0" 3/8" PULL -DOUG MOCKETT DP3, TYP. P.LAM COUNTERTOP PL 1 TILL DRAWER lzo PROVIDED ANDINSTALLED BYinOTHERS P.LAM BASE CABINET & SHELVING PLa P.LAM 2 3/4" COUNTERTOP " = 1'-0" 14 I ELEVATION - POS CUST. SIDE 3/8" = 1'-0" P.LAM COUNTERTOP P.LAM COUNTERTOP 4" 3 1/2" PL-1 PL-1 9 N 1" PAINTED WOOD "Ls o 0 SHELVING00 n Pan 3/8" = 1'-0" 3 ELEVATION - POS CUST. SIDE 5'-2" 0 A6.02 / 10 3/8" = 1'-0" 11 ENLARGED PLAN - P.O.S. �i P.O.S. 110 225' o J N,0 A6.02/3 135' / 8 2'. 4" SOFFIT EXISTING PNEUMATIC TUBES TO REMAIN P.LAM COUNTERTOP EXISTING CASH DRAWER TO REMAIN O PL.1 !p PROVIDE WIRE GROMMETS FOR PWR / DATA AT EA. POS STATION - 8" FROM FACE OF COUNTER CONDUIT 3/8" = 1'-0" ASDSKY' 1240 East 5th Avenue Tampa, FL 33605 T 813.223.2293 F 813.223.2433 www.asdsky.com LJ S' RJ E R R A �U J <�/LO (n LO ry M N L.L �1 In > J 3ILL. UJ -C N W J U) U) ui 1— a � m Y 4 � N m � � 9 x/1 _s� This drawing is the property of Associated Space Design, Inc. and is not to be reproduced or copied in whole or part. It is not to be used on any other project and is to be returned upon request. Scales as stated herein are for reference only as normal reproduction processes may alter the accuracy of original drawings. Associated Space Design, Inc. 2018 NO: DATE: REMARKS'. REVISIONS: SAWING TITLE'. INTERIOR ELEVATIONS & ENLARGED PLANS 51394.64 05-23-18 V BY: CHECKED BY: AC KN NUMBER. A6.02