HomeMy WebLinkAboutPRODUCT APPROVAL ROOFING TILES3/27/2018
Florida Building Code Online
5CIS Homy Log In 1 Uaer registration : tint16oic%
�k + t{ 1,14i Product Approval
p1'USER: Cubhc User
rw x
sx �
I)& k r s FI
Application Type
Code Version
Application Status
Comments
Archived
Product Manufacturer
Address/Phone/Email
Authori'2ed Signature
Technical Representative
Address/Phone/Email
Quality Assurance Represcntal.ive
Address/Phone/Email
Category
Subcategory
Compliance Method
Florida Engineer or Architect Name who dove
the Evaluation Report
Florida License
Quality Assurance Entity
Quality Assurance Contract Expiration Date
Validated By
Certificate of Independence
Referenced Standard and Year (of Stand
Equivalence of Product Standards
Certified By
SGANNF
r n
3CIS S}ze p�P
Vs�!��lj�,yy �
��
ij Public atidns r[3C Staff Map Links
,I ;, Application Detail
FL7473-R8
Revision
2017
Approved
EAGLE ROOFING PRODUCTS FLORIDA LLC
1575 East CR 470
Sumterville. FL 33858
(800)400-3245
annettes@eagieroofing.com
Annette Sindar
annette.sCq cagleroofing.com
Tyler Allwood
1.575 East Country Road 470
Suntterville, FL 33585
(941) 302- 7826
tylera@eagleroofing.com
Roofing
Roofing Tiles
Evaluation Report from a Florida Registered Architect or a Licensed Florida
Professional Engineer
Evaluation Report - Hardcopy Received
Robert Nieminen
PE-59166
Architectural Testing, Inc., an Intertek company
12/31/2020
John W. Knezevich, PE
rlt� Validation Checklist - Hardcopy Received
FlZ�7."���t i ��I.. 2rlvj�i _COT Nieminen_it,�,c'f
Standard
Year
ASTM C1492
2009
FRSA/TR1 April 2012
2012
SSTD 11
1997
Sections from the Code
)lttps:h'www.floridabuildi ng.
1 PtVBTji%2f7gT7a%2fuMUFZf11 M%3d
12
3/27/2018 Florida Building Code Online
Product Approval Method
Date Submitted
Date Validated
Date Pending FBC Approval
Date Approved
Summary of Products
Method 1 Option D
10/1.6/2017
10/18/201.7
10/19/2017
12/12/2017
FL # ; Model, Number or
11arne
Description
7473.1 Eagle Roor Tiles
Low (flat), medium and high profile concrete roof tiles
------
------ -- ------------..-i_---___-..._. ____._._.._-
Limits of Use
-- _ .____._
_-_•______•m_. ....w.._..._ _ _......_._-__—_ __.____
€ Installation Instructions
Approved for use in HVHZ: No
fj_7473 Lf',jI 21V I F"TV�L C2._EAGLc_?vON-
Approved for use outside HVHZ: Yes
H.Vi-17 Ft-74
I Impact Resistant: N/A
Verified By: Robert I M. Nieminen PE - 59166
Design Pressure: N/A
Created by independent Third Party: Yes
Other: See Section 5 of Evaluation Report lot
Limits of Use.
Evaluation Reports
'rile roofs are analyzed for wind resistance thr
ugh overturning i 1`0747 i_!ty _t?,i=_ 201.7 1.0 FINAL F;2 EAGI-=' ra lN-
—--_•._� _.
rriament, Refer to FRSA/ TRI 07320 for overfur
Ling moment
hVI�T � I r- ky Z R?..t1c)1
limitations of mechanically attached file sysLet
s and the tile
Created by Independent Third Party: Yes
adhesive manufacturers' Product Approvals foi
adhesive set
the systems.
Cvnt.:ct lis 26 ! S!alr Scone R^ad, T:!!ahassee F1. 32?99 Phe��eTi3_ �_4f3;•L87.4
the State of Florida is an AA/UO employer. Cog',rlo t 200 -201.3 State of Flonda.:: pr_, evacy Statement Accessibi RY. Slatement :: ReAinf Ssgte_,{LL; ns
under Flonda law, email addresses are public records- if yo dv not want your a -malt address released in response to a public -records reaaest, do nol --1
nail to this emit,. Instead, contact the office by phen or by tradttirr(al mail. it you have any queshnr±s, please a}ntact 8S0.tS7.3395. -Pursuant ta`-echort
%SS.1: 51,t), Florida Statutes, frfWive OCtober I; 2012, 11 engca5 licensed under chapter 455, F.S. n,us: provide the De!iartmentwith an etnall address ;( they h.. +vc
ane. The emails provided may he used ror r}fricial communi ation with the hicensee. However email addresses are public record. if you de not wish to supni, a netsa�ai
address, please provide the Devartment with an ernad add ess which car be made availablc to the public. To determine !f you are a licensee. under C.haut�-t 455, r,c.••
please click here .
Product Approval Accepts:
' t.v
Credit cafd
Safe
sklemm
litips://www.
1 PtVBTji%2f7gT7a%2fuMUFZfI I rvl%3d
RWA
r'
TIR -I ERD
EVALUATION REPORT
Eagle Roofing Products Florida LLC.
1575 East Country [toad 470
Sumterville, FL 33585
(800) 400-3245
EXTERIOR RESEARCH & DESIGN, LLC.
Certificate ofAuthorizotion #9503
353 CHRISTIAN STREET, UNIT 013
OXFORD, CT 06478
(203) 262-92,15
Evaluation Report E1322.09,06-R5
FL7473-R8
Date of Issuance: 02/24/2009
Revision S: 10/16/2017
SCOPE:
This Evaluation Report is issued under Rule 61G20-3 and the applicable rules and regulations governing the use of
construction materials in the State of Florida. The dc cument'ation submitted has been reviewed by Robert Nieminen,
P.E. for use of the product under the Florida Bllll( ing Code and Florida Building Code, Residential Volume. The
products described herein have been evaluated foi compliance with the 6"' Edition (2017) Florida Building Code
(NON-HVHZ) sections noted herein.
DESCRIPTION: Eagle Roof Tiles
LABELING: Labeling shall be in accordance with the requirements the Accredited Quality Assurance Agency noted
herein.
CONTINUED COMPLIANCE: This Evaluation Report is vall
Quality Assurance documentation changes, or provi;
this Evaluation Report by the named client consti
changes or the referenced Quality Assurance docun
Evaluation Report relative to updated Code requirer
ADVERTISEMENT: The Evaluation Report number prec
displayed in advertising literature. If any portion I
entirety.
INSPECTION: Upon request, a copy of this entire EvaIL
its distributors and shall be available for inspection
This Evaluation Report consists of pages 1 through 5
Prepared by:
Robert J.M. Nieminen, P.E.
Florida Registration No. 59166, Florida DCAANE1983
CERTIFICATION OF INDEPENDENCE:
1.. Trinity IERD does not have, nor does it intend to acgt
distributing products it evaluates.
2. Trinity I ERD is not owned, operated or controlled by all
3. Robert Nierninen, P.E. does not have nor will acquire,
which the evaluation reports are being issued.
4. Robert Nieminen, P.E. does not have, nor will acquire,
product.
5. This is a building code evaluation. Neither Trinity IERI
project on which this Evaluation Report, or previous ve
specifically for that purpose.
I until such time as the named product(s) changes, the referenced
ons of the Code that relate to the product change. Acceptance of
utes agreement to notify Robert Nieminen, P.E. if the produr,t
2ntation changes. Trinity I ERD requires a complete review of this
ents with each Code Cycle.
ded by the words "Evaluated by Robert Nieminen, P.E." may be
f the Evaluation Report is displayed, then it shall be done in its
ttion Report shall be provided to the user by the manufacturer of
the job site at the request of the Building Official.
_. •—. 6F ,� ��; The ,assm�b± seal appeasag was an@prized It,, Rooe,t N-- n,
' ���+;: ?,`. `..�• P.G. o+: 1UJ IG(7G3'7. This does not sec e as rn e!e<".rprur:,i!y s:gn;�„
�: qLG}r', Jpcwrent. Signed, sealed bardcop,es have xen tren;ntitte±u:>,e
FroductApprovzl Administr3lor and to tt=e named then!
ire or will it acquire, a financial interest in any company manufacturing or
company manufacturing or distributing products it evaluates.
financial interest in any company manufacturing or distributing products for
financial interest in any other entity involved in the approval process of the
nor Robert Nieminen, P.E. are, in any way, the Designer of,Record for any
;ions thereof, is/was used for permitting or design guidance unless retained
ROOFING SYSTEM EVALUATION:
1. SCOPE:
Product Category:
Roofing
Sub -Category:
Roofing Tiles
Compliance Statement:
Eagle Roof Tiles, as
compliance with the following sections of the
in accordance with the following Standards. C
Conditions of Use set forth
herein.
2. STANDARDS:
Section
Property
1507.3.5, R905.3.5
Physical Properties
1507.3.7, R905.3.7
Attachment Requiremi
1504.2.1.1
Overturning Moment
3. REFERENCES:
Entity
Examination
ATL(TST 3782)
ASTM C1492
ATL (rST 3782)
ASTM C1492 — Freeze/
Tile Roof Institute
SSTD 11.
Al I (QUA 1844)'
Quality Assurance
4. PRODUCT DESCRIPTION:
4.1. ASTM C1:492, Type'lIl (Low Profile):
1
t '
RI"T Ys ERD
JLlced by Eagle Roofing Products Florida LLC, have demonstrated
Edition (2017) Florida Building Code (NON-HVHZ) through testing
7liance is subject to the Installation Requirements and Limitations /
121W
Standard Year
ASTM C1.492 2.003(2009)
FRSA/TRI April 2012 (04-12) 2012
SS'I D 11, 1997
Reference Date
RT0310.0.1-17, 02-17, 03-17 03/15/2017
RT0706.01-17, 02-17, 03-1.7 09/25/2017
Membership Letter 11/29/2005
Inspection Report 06/07/2017
I4.BELAIR":
12W
Exterior Research and Design, I.I.C. 6'" EDITION (2(?17) FBC ttlON-HVH'L EVALUATION Evaluation Report E132.2.09.0646
Certificate OfAuthorization #9503 Eagle Roofing Plloducts Florida LLC.; (800) 400.3245 FL7473-ES
Revision 5: 10/16/2017
Page 2 of 5
4.2 ASTM C1492, Type.11 (Medium Profile)" "
..__ _-
MIL
aaLe
4.3 AS.TM C1492, Type t,(High Prof+le
.17,,
171
f
5. LIMITATIONS:
5.1 This is a building code evaluation. Neither TrinitylERD nor Robert Nieminen, P.E. are, in any way, the
Designer of Record for any project or which this Evaluation Report, or previous versions thereof, is/was
used for permitting or design guidanc unless retained specifically for that purpose.
5.2 This Evaluation Report is not for use in FBC IiVHZ jurisdictions.
5.3 Fire classification is not part of this valuation; refer to FBC 1505.2, Exception 2 (for non-combustible
deck) or listing by an approved testing agency for fire rating of this product.
SA Underlayment shall be that which ho Nis Florida Product Approval for use with tile roofing systems. The
underlayment Product Approval sh(( II specify allowable method(s) of tile installation (mechanical
attachment, mortar -set and/or adhesive -set) for use with the specific underlayment. For mortar -set or
adhesive -set tile roofing application) , the underlayment Product Approval shall specify attachment:
methods for the underlayment system to resist wind uplift design loads in accordance with Table 1A of
FRSA/TRI April 2012 (04-12).
5.5 "Color -Bonded" or "Slurry -Coated" files are limited to use on projects in areas subjected to weathering
indices of 50 or less (negligible weathering), as outlined in Figure 1 of ASTM C1492-03(2009)1, reproduced
below for reference. This limitation does not apply to the "Color -Through" product offering.
50
WEATHERING REGIONS
'��"•��ilil� NEGLIGIBLE WEATHERING.
J MODERATE WEATHERING
SEVERE WEATHERING
5.6 All products in the roof assembly shall' have quality assurance audit in accordance with FAC Rule 611520-3.
Erterior Research and Dcsign, LLC. 6"' EDITION•; (2077i FCC NON-HVHZ. EVALUATION Evaluation Report E1322.09.06-R5
Certificate of Authorization 49503 Eagle Roofing Pro, ucts Florida LLC.; (800) 400-3245 FL7473-R13
Revision 5: 10/16/2017
Page 3 of S
6. INSTALLATION-.
6.1 Eagle Roof Tiles may be mechanically
manufacturer's current published inst
FRSA/TRI Florida Nigh Wind Concrete
6.2 Underlayment shall be installed in a
manufacturer's current Product Appr�
Underlayment current Product ApproJ111
resist wind uplift design loads in accorc
rastened, mortar -set or adhesive -set. Installation shall comply with
uctions, but not less than the requirements of FBC 1507.3 and the
and Clay Tile Installation Manual.
cordance with FRSA/TRI April 2012 (04-12) or the underlayment
wal. For mortar -set or adhesive -set tile roofing applications, the
it shall specify attachment methods for the underlayment system to
ante with Table 1A of FRSA/TRI April 2012 (04-12).
6.3 Tile Attachment:
.3.1 Mechanically Attached Tile.,('
Wind load resistance shall be in actor - ante with Table 3 of FRSA/TRI April 2012 (04-12) to resist the Uplift
Moment determined in Table 2A or 2 of FRSA/TRI April 2012 (04-12) or FBC 1609.5.3.
6.3.2 Mortar -Set Tile:
Wind load resistance shall be in acc rdance with Table 2A or 2B of FRSA/TRI April 2012 (04-12) or FBC
1609.5.3 in conjunction with the mor �ar manufacturer's Product Approval.
6.3.3 Adhesive -Set: Tile:
Wind load resistance shall be in accordance with Table 2A or 213 of FRSA/TRI April 2012 (04-12) or FBC
1609.5.3 in conjunction with the adhesive manufacturer's current Product Approval. Refer to the current
version of the referenced Florida Pro uct Approval for paddy -placement details and performance data.
6.3.4
T.ILE'AIDHESIVES
FO ADHESIVE -SET TILE SYSTEMS.
Manufacturer
Products
Florida Product Approval
"touch N' Seal Storm Bond"
FL14506
DAP Foam, Inc.
- —--.._.... __....-._.....................
" -ouch N' Seal Storm Bond 2"
"TILE BOND'""
.............. —
FL21374
Dow Chemical
FL22525
j ICP Adhesives & Sealants Inca; —
;Palyset� AHc'160 --
---- —
Polyset RTA 1"
i CFL6332=
—
FL6276
Nip and wedge Tiler
Tile shall be installed in accordance
atop hip and ridge metal, refer to th
FL5374) or test report in accordanr
accordance with Table 1A of FRSA/TI
th FRSA/TRI April 2012 (04-12). For hip and ridge tile installations
hip and ridge metal manufacturer's current Product Approval (e.g.,
with SSTD 11 for allowable loads to resist those determined in
April 2012 (04-12).
Exterior Research and Design, LLC. 6M EDITION (2.67) FBC NON-1IVli2 EVALUATION Evaluation Report E1322.09.06-RS
CertificoteofAuthorizotion 119503 Eagle Roofing Prbducts Florida LLC.; (800) 400-3245 FL7473-PS
Revision 5: 10/16/2017
Page 4 of 5
7. LABELING:
7.1 Each unit shall bear the imprint or ide
be labeled in accordance with the recIti
i �F INI E R ilLa)
tifiable marking of the manufacturer's name or logo. Tile lots shall
rements of the Accredited Quality Assurance Agency noted herein.
EAUL w�
m a 't
{
L IAEAGLE F L
(1.0C:AT1 D ON UNDE161DL: t)F ll..i?) (LO(--'ATED ON FRO\TSIDE OF TILL)
7.2 Tile not tested for freeze -thaw shall stage clearly that the lot has not been tested for freeze -thaw
acceptance on all lot tags or certificat.lon.
8. BUILDING PERMIT REQUIREMENTS:
As required by the Building Official or Authority Having Jurisdiction in order to properly evaluate the installation of
this product.
9. MANUFACTURING PLANTS:
SUmterville, FL
10. QUALITY ASSURANCE ENTITY:
Architectural Testing, Inc, — QUA1844; (717) 76 -7700
- END F EVALUATION REPORT -
`ASTM C1492-03, standard Specification for Concrete Roof Tile Q0 A51M International
Exterior Research and Design, LLC. G"' EI;ITION (2t>17) FHC NON-HVI-17. EVALUATION Evaluation Report E1322.09.06-115
Certificate ofAuthorizotion 99503 Eagle Rooting P oducts Florida LLC.; (800) 400.3245 FL7473•PS
Revision 5: 10/16/2017
Page 5 of 5
312112018
B05 Home Lng In user r.'.aistratict: - F;et-To0ic5
v
Product Approval
Al
sn, cr
Nigno
3 s
fe+% at x a FL n
Application Type
Cede Version
Application Status,
Comments
Archived
Product Manufacturer
Address/Phone/Email
Authorized Signature
Technical Representative
Address/Phone/Email
Quality Assurance_ Representative
Address/Phone/Email
Category
Subcategory
Compliance Method
Florida Engineer or Architect Name who de,
the Evaluation Report
Florida License
Quality Assurance Entity
Quality Assurance Contract Expiration Date
Validated By
Certificate of Independence
Referenced Standard and Year (of Standard)
Equivalence of Product Standards
Certified By
Sections from the Code
Product Approval Method
Building Code Online
F
Surcha,ye Sacs a Fact Pubhcat,azs FPC Staff sets she Map tin&" '-a'0'
,,i > Application Detail
FL6332-R8
Revision
2017
Approved
ICP Adhesives & Sealants, Inc.
12505 NW 44th Street
Coral Springs, FL 33065
(888) 774-1419 Ext 201
rylipelkoneng,,icpadhesive s.corn
Riku Ylipelkonen
ryli pelkonem;hicpadhesives. corn
Roofing
Roof Tile Adhesives
Evaluation Report from a Florida Registered Architect or a Licensed I In. rde
Professional Engineer
Evaluation Report - Hardcopy Received
Robert Nierninen
PE-59166
UL LLC
02/07/2021
)ohn W. Knezevich, PE
Validation Checklist - Hardcopy Received
FI_G332_fN-OI._2017_ Q1_.CQI,_tJuemaan-pdf
famnd—ard Year
SSTD I 1997
Method 1 Option D
littps://wvAv.floridabuilding.org/pr/pr_app_dt).aspx?param=wGEVX0%,ADq�uaiiCtKft6f%2ft,,4%2b3ax6XpXuocOWi<cL�i12j"/o2bQ%3d 112
1 112018
Building Code Online
Dale Submitted
Date Validated
Date Pending F6CApproval
Date Approved
10/12/20L7
10/14/2.0.17
10/1.7/2017
12/12/2017
summary of Productsa
............
FL # Model, Number or Name
63332.1 1C.P Adhesives Poiy.,2 Ali-1.60
Limits of Use
Approved for use in HVHZ: No j
Approved for use outside HVHZ: Yes I
Impact Resistant: N/A
Design Pressure: +n/a/-1.78
other: 1.) The design pressure limitation in tl is application
refers to hip and ridge tiles in one configuration . Rafe, to Table
2 of ER for all hip and ridge the limitatiotys. <.) =r Id tiles are
designed based on overturning moment reststa xe. Refer to
Table 1 of ER for field tale limitations. 3.) Refer' o FR Sections 5
for other Limitations of Use.
Description
Dual comporienl expanding polyurel.hane root the adhesive
Installation Instructions
M,12SE,
Verified By: Robert Nierninen PE-591.66
Created by Independent Third Party: Yes
Evaluation Reports
il?.._&. r.....�1..f_.1 (l. _f.�,l'r; L � `�.., f.=:.
Created by Independent Third Party: Yes
f 'rty a<A �cn.
ti^der rj c r w; en1wi 5f rt SeS we „:7bi!( er '„ If you do 'A wart you- e-"IM adrlre4, iv l tt. ' to publit-tei d r cur don t fiCAW,0-=<
mad tjlfs entity. I rs,_ad. coytaclt Uic offie.an Lre pho e w bi tada onxl rtail, if you have - ny lwstmfI4. pleat: ror.act 650,;97.2105, to
p5; L a St.ttuiv,;, ' ff _cvvr. ;� goer ., ,, 11, 1 i cpq i-.ees 1:Cen._P Antler Chapter 455. F.S. rrer 5 t prev!de the Di, oartrnent wit ly an Lni it a it ;trey ha3ye
ovided may be. Used f:,v cffuai -uaa... ce. i m With the Iscerxsee Noun mr en+ad addresser. are Public "word. If Yoe do not >n : to sups iy a r.,rf;oi �s
,dress, cretso rucr.ala the bepartrnent with :.n errad acldrr. _> v.hi: h r in be made available l<� th„ „r,orc.:,. jetermine if you are a liceme.e u le., Ch,r,.e ,
Ut'.w,e diet Ftta_ L, t .
Product Approval Acrepts:
SfnediI; 11"ar
safe
https://avvnv.(loridabuilding.org/prlpr_app_dtl.aspx?paratn=vjGEVXdwADt uanCtKft6f%2fM"/o2b3ax6XpXuocQOII<cLNI2j`/`2bCi%3d 212
11 ERD
EVALUATION REPORT
ICP Adhesives and Sealants, Inc.
12505 NW 44th Street
Coral Springs, FL 33065
(888) 774-1419
SCOPE:
This Evaluation Report is issued under Rule 61G20
construction materials in the State of Florida The d
P.E. for use of the product under the Florida Build
compliance with the 6th Edition (2017) Florida Buildi
DESCRIPTION: ICP Adhesives Polyset' AH-160
LABELING: Labeling shall be in accordance with the
herein.
CONTINUED COMPLIANCE: This Evaluation Report Is vall(
Quality Assurance documentation changes, or provisi
this Evaluation Report by the named client constit
changes or the referenced Quality Assurance docuni
Evaluation Report relative to updated Code requirem
ADVERTISEMENT: The Evaluation Report number preci
advertising literature. If any portion of the Evaluatiol
INSPECTION: Upon request, a copy of this entire Evalu;
its distributors and shall be available for inspection al
This Evaluation Report consists of pages 1 through 9.
Prepared by:
Robert J.M. Nieminen, P.E.
Florida Registration No. 59166, Florida DCAANEI
EXTERIOR RESEARCH & DESIGN, LLC.
Certificate of Authori2otion #9503
353 CHRISTIAN STREET, UNIT 13
OXFORD, CT 06478
(203) 262-9245
Evaluation Report 02768.03.06-RB
FL6332-R8
Date of Issuance: 08/08/2008
Revision 8:10/12/2017
and the applicable rules and regulations governing the use of
umentation submitted has been reviewed by Robert Nieminen,
Code. The product described herein has been evaluated for
Code sections noted herein.
requirements the Accredited Quality Assurance Agency noted
Ii until such time as the named product(s) changes, the referenced
bns of the Code that relate to the product change. Acceptance of
tes agreement to notify Robert Nieminen, P.E. if the product
�`ntation changes. Trinity I ERD requires a complete review of this
ants with each Code Cycle.
ded by the words "Trinity I ERD Evaluated" may be displayed in
i Report is displayed, then it shall be done in its entirety.
Ition Report shall be provided to the user by the manufacturer or
the job site at the request of the Building Official.
c- -n oe
•; '.�.
The facsimile seal appearing was authorized by Robert
.•
Nieminen, P.E. on ID/12/2017. This does not serve as an
;•;n��i.; ,, ,"'
electronically signed document.
CERTIFICATION OF INDEPENDENCE:
1. Exterior Research & Design, LLC. d/b/a Trinity I ERD does not have, nor does it intend to acquire or will it acquire, a financial interest
in any company manufacturing or distributing products itl evaluates.
2. Exterior Research & Design, LLC. d/b/a Trinity I ERD is not owned, operated or controlled by any company manufacturing or
distributing products it evaluates.
3. Robert Nieminen, P.E. does not have nor will acquire, a inancial interest in any company manufacturing or distributing products for
which the evaluation reports are being issued.
4. Robert Nieminen, P.E. does not have, nor will acquire, a financial interest in any other entity involved in the approval process of the
product.
5. This is a building code evaluation. Neither Trinity IERD nor Robert Nieminen, P.E. are, in any way, the Designer of Record for any
project on which this Evaluation Report, or previous ver ions thereof, is/was used for permitting or design guidance unless retained
specifically for that purpose.
ROOFING COMPONENT EVALUATION:
1. SCOPE:
Product Category: Roofing
Sub -Category: Roof Tile Adhesives
Compliance Statement: ACP Adhesives Poly:
demonstrated compliance with the 6"' Edition
Standards set forth herein. Compliance is Sul_
Use set forth herein.
2. STANDARDS:
. S
TRINI
i �� • l
AH-160, as produced by ICP Adhesives and Sealants, Inc., has
17) Florida Building Code through testing in accordance with the:
to the Installation Requirements and Limitations / Conditions of
Sections
Property
Standard
Year
1.504.2.1.1
Overturning resistar
ce SSTD 11
1997
3. REFERENCES:
Entity
Examination
Reference
Date
ERD (T5T 6049)
Static Uplift — SSTD
1 P39740.02.12
02/20/2012
ERD (TST 6049)
Static Uplift — SSTD
11 P39740.11.13-R1
01/02/2015
ICC-ES (EVL2396)
2012 IBC Compliance
ESR-1709
12/01/2016
Miami -Dade (CER 1592)
HVHZ compliance
17-0322.03
L1
04/27/2017
PRI (TST 5878)
Static Uplift — SSTD
ECM-001-02-01
09/21/2001
PRI (T5T 5878)
Static Uplift — SSTD
1 PFI-006-02-01
05/09/2005
PRI (TST 5878)
Static Uplift — SSTD
I 1 PFI-006-02-02
05/09/2005
PRI (15T 5878)
Static Uplift — SSTD
L1. PFI-007-02-01
10/11/2005
PRI (TST 5878)
Static Uplift — SSTD
Ll PFI-008-02-04
02/21/2006
PRI (TST 5878)
Static Uplift — S57D
Ll PFI-009-02-03
02/21/2006
PRI (TST 5878)
Static Uplift —SSTD
L1 TGRI-001-02-03
10/30/2006
PRI (TST 5878)
Static Uplift —SSTD
11 TGRI-001-02-03
10/30/2006
PRI (T5T 5878)
Static Uplift — 55TD
1 PFPI-010-02-01
12/07/2006
PRI (TST 5878)
Static Uplift —SSTD
1 PFPI-011-02-01
12/07/2006
PRI (TST 5878)
Static Uplift —SSTD
L1 PFPI-012-02-01
12/07/2006.
PRI (TST 5878)
Static Uplift — SSTD
11 PFPI-013-02-01
12/07/2006
PRI (TST 5878)
Static Uplift —SSTD
11 PFPI-014-02-01
1.2/07/2006
PRI (T5T 5878)
Static Uplift —SSTD
11 ECM-003-02-01
06/13/2008
PRI (TST 5878)
Static Uplift — SSTD
1, 1. ECM-004.02-01
06/13/2008
PRI (TST 5878)
Static Uplift — SSTD
11 ECM-005.02-01
06/13/2008
PRI (TST 5878)
Static Uplift— SSTD
11, ECM-006-02-01
06/1.3/2008
PRI (TST 5878)
Static Uplift — SSTD
11. ECM-007-02-01
06/13/2008
PRI (TST 5878)
Static Uplift — SSTD
1 ECM-008-02-01
06/13/2008
UL LLC (QUA 962.5)
Quality Assurance
Service Confirmation
Exp. 06/05/2018
4. PRODUCT DESCRIPTION:
4.1 ICP Adhesives Polyset"' AH-160 is a two -component expanding polyurethane roof the adhesive that is mixed
and dispensed from a dispensing system provided by ICP Adhesives and Sealants, Inc. The components are
available in refillable tanks or disposable c tinder s (ICP Adhesives ProPack° 30 & 100).
S. LIMITATIONS:
5.1 This is a building code evaluation. Neither Trinity) ERD nor Robert Nieminen, P.E. are, in any way, the Designer
of Record for any project on which this Evaluation Report, or previous versions thereof, is/was used for
permitting or design guidance unless retained specifically for that purpose.
5.2 This Evaluation Report is not for use in FB IC HVHZ jurisdictions.
Exterior Research and Oesign, I.I.C. Evaluation Report 02768.03.06.148
Certificate o/Authorization k9503 6 ELATION (2017) f t3C NOW-I-iVH-L EVALUATION FL5332-it8
ICP Adhesives Poly etm AH-160; (888) 774-1419 Revision 8:10/12/2017
Page 2 of 9
5.3 Fire classification is not part of this evalua
of this product and FBC 1505.2.
Refer to a current Roofing Materials Directory for fire ratings
5.4 ICP Adhesives Polyset` AH-160 can be usc�d with flat, low and high profile tiles or any rigid, discontinU0U5 roof
assembly having a current Florida Statewide Product Approval or approved on a local -level by the Authority
Having Jurisdiction.
5.5 Minimum underlayment shall be per FR
Product Approval or approved on a local -I
Polyset' AH-160.
5.6 Field tiles, meeting the limitations of FE
projects having an Aerodynamic Uplift Ms
2A and 2B of FRSA/TRI April 2012 (04-1
values. Refer to Section 10 and ICP Ai
Adhesive Paddy Placement details.
RI April 2012 (04-12) or having a current Florida Statewide
by the Authority Having Jurisdiction for use with ICP Adhesives
1609.5.3, using ICP Adhesives Polyset° AH-160 are limited to
ment (M,), determined in accordance with FBC 1609.5.3 or Tables
!), not greater than the following Allowable Overturning Moment
hesives and Sealants, Inc. published installation instructions for
TABLE 1 FIELD
ILES IN ICP A A61VES POLYSET`AH 160;
ALL OWABLE'OVERTURNING
MOMENT PERFORMANCE DATA
;. 2 r0 J1 MARGIN,or6AFETY,ALREADYAP
I=�
LIED FOR INDiPENDENr(SiN(�Lt,dfi CONTINUOUS PADDY) PLACFMEN7
4%..
•
-,--0i01 MAREi1NOf-SAFETYALR
_
R%INTERDfPENDMr(TWO ➢ADDY PWFAVNu;
'ADY A➢Fllfb FO, _
Tile (FBC
-
1609.5.3)
Adhesive Paddy Placement
Allowable
Overturning
Type
Profile
Moment (ft-lbf)
Gay or
Concrete
Flat
Independent; Single P
Independent; Single P
-
Interdependent; Two
ddy, Medium (2x7-inch, -30 gram)
ddy, Large_(2x10-inch, -45 gram)
--. ..... ......... ---
'addy (44-inch on underlayment, 2x/1-inch at tile overlap)
60 — —
112
-
54
Independent; Single. P
ddy, Medium (2x7-inch, -30
39
Clay or
Low/
_..... ....
Independent; Single P
_._... ,_.. gram)
ddy, Large (2x10-inch, -54 gram)
_. _._.-.... ---.._.._...I
67
Concrete
Medium
- - ---- ..................-.._...
Interdependent; Two
— _
'addy (4x4-inch on underlayment, 2x4-inch at tile overlap)
58 I
Clay
High
Independent; Single P
Wdy, Large (2x1U-inch, -45 gram)
—
134-v
Clay
Iiigh
Independent; Single Paddy,
Independent; Single P
Medium (2x7-inch, -30 gram))
ddy, Large (2x10-inch, -63 gram)
65
109
Concrete
—
Interdependent; Two Paddy
----
(4x4-inch on underlayment, 2x4-inch at file overlap)
'. -
40
Clay
Barrel
2x10-inch x "35 gram
7or pans; 2 @ WO -inch x-17 gram for cap
147
Concrete
_._-....._
barrel
-
2x10-inch x -35 gram
.. ..................... .
or pans; 2 @ 1x10-inch x -17 gram for cap
_ __ .....-......
I 107
Clay
Cap a op 2x
Independent: Continuous
Paddy (" 34 gram/ft)
! 13stri5
er
--
Concrete
Cap atop 2x
stringer
Independent: Continuous
Paddy ("' 34 gramift)
� 116
Clay
y
Cap atop 2x
Interdependent:
1 i
i 105
Concrete
stringer
Cap atop 2x
Head: One (1) #10 x 2X"
Interdependent:
screw; Overlap: 1 x 6 inch (-10.5 gram)
76 i
stringer
Head: One (1.) #10 x 2q%"
screw; Overlap: 1 x 6 inch (" 10.5 gram)
5.6.1 Data in Table 1 relates to installation ov r a '30/90' underlayment system, as detailed in the FRSA/TR► April
2012 (04-1.2). Alternate underlayment ystems include those having a current Florida Statewide Product
Approval and/or approved on a local-le�el by the Authority Having Jurisdiction specifically for use with ICP
Adhesives Polyset", AH-160.
5.6.2 Tile roof systems using the types or profiles other than those listed above acquiring acceptance for use with
ICP Adhesives Polyset° AH-160 shall be jtested in accordance with SSTD 11 or Testing Application Standard
TAS 101. For the interdependent two -paddy method, an additional 2-to-1 margin above that specified in
SSTD 11 or Testing Application Standaril TAS 101 shall be applied in determining the 'allowable overturning
moment'.
Exterior Research and Design, LLC. I Evaluation Report 02768.03.06-R8
Certificate ofAuthorhation p9503 6"` EDITION (2017) 16C NON-HVli2 EVALUATION FLO332-RB
ICP Adhesives Poly sete AH-160; (888) 7744419 Revision 8: 10/12/2017
Page 3 of 9
5.7 Hip and ridge tiles using ICP Adhesives Poly:
requirements, determined in accordance w
following values. Refer to ICP Adhesives
Paridv Plarement details.
fTRINITYERD
W AH-160 are limited to projects having hip/ridge design pressure
th 'rabic 1A of FRSA/TRI April 2012 (04-12), not greater than the
Ind Sealants, Inc. published installation instructions for Adhesive
" TABLE 2 HIP t RID6E
TILES tN ICP ADHESIVES'POLYSE'Tt AH-166
it ' i4LLDWABLE UPLIFT
RESISTANCE PERFQRMANCE:DATA
i �. t 4
1701 MARGIN OF SAF£TYIICRFADi
APPLIED FOR INDEPENDENT (LON7INUOUS PADDY PLACEIb1EN7
,_..
4,To 1-MARdWO F•SAFE7YALR£AbYAPPbEb
FOR INTERDEPENDENT PL9CEMFNT
Allowable
Tile
Substrate
Attachment Method
Design Pressure j
Clay
2x PT ridge board
Independent: Continuous Paddy (-34 gram/ft)
116
Concrete
_
2x PT ridge board
Independent: Continuous Paddy (- 34 gram/ft)
107
Interdependent: Head: One (1) 010 x 2y," screw;
90
Clay
2x PT ridge board
Overlap: 1 x 6 inch (-10.5 gram)
Interdependent: Head: One (1) 410 x 2%" screw;
56
Concrete
2x PT ridge board
Overlap: 1 x 6 inch (-10.5 gram)
_
Clay or
_�_
Hip & Ridge Channel Metal (FL5374):
_
.._...._......_...... .... .... _.....
Independent: Continuous Paddy ("34 gram/ft)
169
Concrete
galvanized only
I
Clay or
tTrirn Lock '(FL537 }): uiumrriium; .y
_
Independent: Continuous Paddy;f 34 gram/fit)
3
,Concrete +,
Clay or
galvanized Golvalumel or stainless s
Trim Lock'" Plus (FI.5374): oluminurrr
eel
ft
_
178
Paddy dent: Continuous Independent: 34
P y (N gram / )
Concrete
golvonizer, Golvolume„ or stainless s
eel
Clay
Top Notch (FL8095)
Independent: Continuous Paddy (" 32 gram/ft)
125 j
Concrete
Top Notch (FL8095)
Independent: Continuous Paddy (` 32 grain/ft)
146
i
6. INSTALLATION:
6.1 ICP Adhesives Polyset® AH-160 and the tile roof assembly shall be installed in accordance with FRSA/TRI
April 2012 (04-12) and ICP Adhesives and Sealants, Inc. published installation instructions, subject to the
limitations outlined in Section 5.
6.2 Hip and ridge boards or hip/ridge metal sh II be installed in accordance with the FRSA/TRI April 2012 (04-12).
Proprietary hip and ridge metal shall be installed in accordance with the manufacturer's Florida Product
Approval. 1
6.3 Installation shall be performed by applical ors who hold a valid Qualified Applicator Card presented by ICP
Adhesives and Sealants, Inc.
7. BUILDING PERMIT REQUIREMENTS:
As required by the Building Official or Aut
installation of this product.
8. MANUFACTURING PLANTS:
Tomball, TX
9. QUALITY ASSURANCE ENTITY:
UL, LLC. — QUA9625; (847) 664-3623;
rity Having Jurisdiction in order to properly evaluate the
Exterior Research and Design, U.C. Evaluation Report 02768.03.06-112
Certificate oJAuthori:ation #9503 6 "EDITION (20.17) FLOC NON-HVhIZ EVALUATION FL6332-RS
ICP Adhesives PolysGltO AH-160; (888) 774-1419 Revision 8:10/12/2017
Page 4 of 9
10. PADDY PLACEMENT DETAILS (FROM ICP ADHESI\
10.1 Independent, Medium Paddy:
Nail through plastic Cement Paddy lReneoth Tile)
(when required)
Underlayment
:• :JTRINITY ERD
9D SEALANTS, INC. PUBLISHED LITERATURE):
,j"lut. o r
r
Y�5
Uattens optional "
Eave Course
t IOm i ,
efr
Fos(
,
EnveClosure .ti if,�.✓r
Nall through plastic cement
(when required)
4.
Underlayment '
f
__ Paddy (Beneath Tile) 9
7in;.
2 in sa" ^
Battens optional
' y
✓
a o 101n `ice* 2 m ,F
S
Eave Closure
ryes •,, i ,�` ,'
Eave Course ,`'•' — Fascla
Flat/Low Profile Tile
Medium Profile Tile
Nall through plastic ceme
Paddy(BeneathTile)
(when required} 1
Underlayment
7 n': ^� tfi
2'
Battens optional
a �..`OY\ / } Tub ✓ �.
Y it Edve Course ^� Faso
Weephole
t.
"r Eave closure
`a. ,�►' cs" Drip edge
'x
High Profile Tile
Exterior Research and Design, LLC. Evaluation Report 02768.03.06•118
Certificate oJAuthorizotion #9503 (,1' EDITION (2017) FBC NON-FINii'L EVALUATION FL6332•128
ICP Adhesives Polyslo AH-160; (888) 774-1419 Revision 8: 10/12/2017
Page 5 of 9
10.2 Independent. Lame
Nail through plastic cement PlIddy (Ben eath Tile)
iwheit required)
Underlayment
10 in:
Eave Cour.w
'Fascia
Eave Closure
Flat/Low Profile Tile
Wall through Plastic CQII))Qnt
(when required)
Underlayment
10in.x
Optional
Eave
Course
loin. ^ 2 in.
Nail through plastic cement
(when required)
Underlayment I
'Z.
",,JTR.INffYI--.RD
Paddy (fieneafli flk-)
2 in, wide
Battens optional
-;7,
2 1
Eave Closure
011
Eave Course
Fascia
mmommmomma"WA
'rofileTile
Medium Profile Tile
Paddy )Beneath Tile;
Weephole
Eave closure
Drip edge
Exterior Research and Design, LLC, I Evaluation Report 02768.03.06-R8
Certificate ofAuthorization #9503 6"' EDITION (2017) M5 NON-HVIV EVALUATION FUS332-R8
ICPAdhesives Polyset All-160;(888)774-1419 Revision 8: 10/12/2017
1 Page 6 of 9
10.3 Interdependent, Two Paddy
Nail throughplasticcement Paddy (between tilesi
(when re•gmred),
B,altens optional,. i
I Paddy hinder ti e)
Single paddy Y %•
on top of tle " {
4x4in.
t J Single p add
under til
Singlepaddy�� f t
on underlaymenI, ,y- 2 x 4 in. ~� �10m it t r
y 2 In.
EarnClnsule
i
TRINITY
' ERD
paddy under tile
Paddy (betrvee❑ tiles)
i,
j Paddy (under tile)
r `
x4in.
" -.
v�ti ' 'r m''•s
tin
Eave C losure
Y
\� Fascia
Flat/Low Profile Tile Medium Profile Tile
Nail through plastic ce0teu't $ingIepad dyundertile
(when required) F' ' •; '
Paddy (between tiles)
Battens
optional �:e. -'^ 1 Paddy0indertile)
r Slnylr paddy e l r
on tln<ler layment ,n,
�. q l
t 4 x4 in.
Single 44
s'y %
pazldyott
top of the
~ )liet �r p ' rr
Eavi� Course , y ' `Fascia
} / T !1`
I Weep hole
�
• err` �'� Eaveclosure
10in,
21n
Drip edtde
,I,.
Hli h Profile Tile
Exterior Research and Design, LLC, Evaluation Report 02768.03.06-R8
Certificate gfAuthorization#9503 6r"EDITION- (2017)Ft3 NON-HVH2EVALUATION FL6332-118
ICP Adhesives Polyset" AH-160; (888) 774-1419 Revision 8: 10/12/2017
Page 7 of 9
10.4
10.5
A 'It ,111ctlf PKI-It 4h,- 5M
Exterior Research and Design, I.I.C.
Certificate of Authorization #9503
NON-fIVHZ EVALUATION
AH-160; (888) 774-1419
j
ffY ERD
TRIN
Evaluation Report 02763.03.06-R8
F1.6332-1118
Revision 8: 10/1212017
Page 8 of 9
10.6
Exterior Research and Design, I.I.C.
Certificate of Authorization #9503
TRINITYERR
Evaluation Report 02768.03.06-RS
FL.6332-PA
Revision 8: 10/12/2017
Page 9 of 9