HomeMy WebLinkAboutELECTRICALLOCATION: MAINTENANCE BLDG SPEC: SQUARE 171 EXISTING M NEW PANEL "NH" SCHEDULE M COPPER BUS V OR EQUAL ::]ALUMINUM BUS CKT. LOAD DESCRIPTION Z<' WIRE GIRD. COND, _P_O�LE/ TRIP A PHASE B PHASE ___F _­KVA C PHASE PO-LE/ I TRIP COND. GRD. WIRE LOAD DESCRIRTION CKT. 1 SITE LTG #8 #10 1- 30 30 ill #10 #8 1 SITE LIGHTING 2 3 SITE LTG #8 #10 1" 30 - 475T-45 30 1. #10 #8 1 SITE LIGHTING 4 5 SITE LTG #8 #10 ill 30 - 4_5_76_.O­ 3-0 _1" #10 #8 1 SITE LIGHTIN 6 7 SITE LTG #8 #10 -1" -To-- 0 4 - 5 - - 30 1. #10 #8 1 SITE LIGHTING 8 9 SITE LTG #8 #10 30 So - - 3.0 1 4.5 - 30 1" #10 #8 1 SITE LIGHTING 10 11 SI TE LTG #8 #10 lv_�F_30_ 4,5 0.5 30 1- #10 48 1 SITE LIGHTING CONTROL 12 13 j3 R-2.2 - 30 ill #10 #8 DRIVE LIGHTS . / CCNTROL 14 15 2.6 2.0 30 ill #10 #8 LANDSCAPE /CONTROL /BLDG SIGN 16 17 SPACE 18 19 20 21 22 23 25 .0 ��25.0 100 1 1/4" #8 1 #3 'T3'(75kVA XFMR) __24 26 -28 30 27 29 125.0 ALL FEEDER CALCULATIONS ARE BASED ON:THHN/THWN CU. NOT MORE THAN 4 CONDUCTORS IN A RACEWAY SUBTOTAL 42.2 1 43.5 1 40.0 __ CIRCUIT TYPE SHUNT TRIP 0 GROUND FAULT @ DEDICATED ID ISOLATED GRD. TOTAL 125.7 KVA TOTAL 151.3 AMPS TOTAL CONNECTED LOAD= 151.3 AMPS ESTIMATED DEMAND LOAD= 159.6 AMPS POLE TRIP TYPE RATED VOLTAGE= 277/480 VOLTS 3 PHASE 4 WIRE M EQPT. GRD. ID ISOL. GIRD. MAINS: 0M.L.C. M BREAKER 3 I 400 FEEDER SIZE IS: MCABLE = SEE RISER EIBUSWAY = BRANCH POLES: 301: BRANCH BREAKERS= 14 KAIC MOUNTING: N SURFACE 11 FLUSH 13 FREE STANDING 0 KEYED DOOR: BUS RATINGI 400A BRACING = 14 KAIC NEUTRAL BUS IS: C__I HALF SIZE M FULL SIZE Ill KRATED (1.5) 13 KRATED (2.0) GROUND BAR: M EQUIPMENT ED ISOLATED ED OTH ENCLOSUR M NEMA 1 E-I NEMA 3R [::] NEMA 0 CLASS ? DIV ? FEED LOCATION : 0 TOP M BOTTOM ED ED THRU PANEL TYPE DFUSED 0 CB PLUG IN El CB BOLT IN BRANCH E:INORMAL 0 EMERGENCY 0 NINTERRUPTABLE S = SAME AS ITEM OR DEVICE AS ABOVE I CALCS: -LTG 0 125% (50.7 X 1.25) = 63.4kVA, EQUIP 0 100% (69.2 X 1.0) = 69.2kVA => TOTAL = 1,32.6k4A = 159.6A LOCATION: MAINTENANCE BLDG EXISTING M NEW PANEL "NL" SCHEDULE SPEC: SQUARE 1' M COPPER BUS I:] OR EQUAL ALUMINUM BUS CKT. LOAD DESCRIPTION WIRE GRID. COND. POLE/ TRIP KVA A PHASE KVA B PHASE KVA C PHASE POLE/ TRIP COND. GRID. WIRE ��/ LOAD DESCRIPTION CKT. R. V. 1 #6 #8 2" 50 5.0 5.0 50 2- #8 #6 R.V. 4 2 4 3 5 R.V. 2 #6 #8 2" 50 2- #8 #6 R.V. 5 6 8 7 9 _11 R.V. 3 #6 #8 2" 50 50 2- #8 #6 R.V. 6 lo 12 13 SPACE - - - - - - - - SPACE __T14 15 SPACE 10 20 1 1 L2" #12 #12 LIGHTING - MAINT. SHED 16 17 SPACE __dA_TE__ 1.0 20 1/2" #12 #12 LIGHTING - MAINT. SHED 18 19 SOUTH #8 #10 _1" 20 -_ 1.5 1.5 20 1. #10 #8 NORTH GATE 20 21 GATE SIGN fl 0 1" fO 30 ill #10 #10 WELL WATER PUMP 22 24 -26 23 SPACE - - - 25 RECPTS - MAINT. SHED #12 #12 1 2 27 RECPTS - MAINT. SHED #12 12 Ri* 1 2" 20 - 30 ill #8 #8 PANEL 'NLA' 28 30 29 RECPTS - MAINT. SHED 1/2" 20 - 1 0 0.6 ALL FEEDER CALCULA11ONS ARE BASED ON:THHN/THWN CU. NOT MORE THAN 4 CONDUCTORS IN A RACEWAY SUBTOTALI 25.0 24.2 24.0 CIRCUIT TYPE SHUNT TRIP 0 GROUND FAULT (@ DEDICATED @ ISOLATED GIRD. TOTAL 74.2 KVA TOTTAL 199.0 AM PS TOTAL CONNECTED LOAD= 199.0 AMPS ESTIMATED DEMAND LOAD= 199.0 AMPS I POLI RATED VOLTAGE= 120/208 VOLTS 3 PHASE 4 WIRE 0 EQPT. GRD. ED ISOL. GIRD. MAINS: MM.L.O. 0 BREAKER FEEDER SIZE IS: WCABLE = SEE RISER E] BUSWAY BRANCH POLES: 30 BRANCH BREAKERS= 10 KAIC MOUNTING: M SURFACE 0 FLUSH El FREE STANDING E] KEYED DOOR: BUS RATING: 200A BRACING = 10 KAIC NEUTRAL BUS IS: E] HALF SIZE M FULL SIZE 0 KRATED (1.5) EJ KRATED (2.0) GROUND BAR: 0 EQUIPMENT 0 ISOLATED I-1] BOTH ENCLOSURE WNEMA 1 EI NEMA 3R 0 NEMA 4X CLASS ? DIV ? FEED LOCATION : E] TOP W BOTTOM [--]FEED THRU PANEL TYPE 0FUSED M CB PLUG IN [71 CB BOLT IN BRANCH EDNORMAL 0 EMERGENCY ED LNINTERRUPTABLE I S = SAME AS ITEM OR DEVICE AS ABOVE I SPECIAL NOTES: - I LOCATION: FENCE GATE 1) 11 SPEC: SQUARE V E__IEX1STING M NEW PANEL NLA SCHEDULE M COPPER BUS [::]ALUMINUM OR EQUAL BUS CKTJ LOAD DESCRIPTION \Z<� WIRE GRD. COND. POLE/ TRIP KVA A PHASE KVA B PHASE POLE/ TRIP COND. GIRD. WIRE 1��/ LOAD DESCRip riON CKT. 1 SEC GATE 1 12 12 1 2" 20 20 1/2" #12 #12 ADDRESS SIGN 2 3 SEC GATE 2 #12 #1 1/2- 20 0.57-0.1 4 5 SPARE - - . 1/2- 20 20 1 2"' 12 #12 PHOTOCELL 6 7 8 9 10 11 12 ALL FEEDER CALCULATIONS ARE BASED ON:THHN/THWN CU. NOT MORE THAN 4 CONDUCTORS IN A RACEWAY ___S_U­BT0TAL 0.8 0.6 CIRCUIT TYPE SHUNT TRIP (D GROUND FAULT @ DEDICATED 43) ISOLATED GIRD. TOTAL 1.4 KVA TOTAL 6.7 AMPS TOTAL CONNECTED LOAD= 6.7 AMPS ESTIMATED DEMAND LOAD= 5�7 AMPS POLE TRIP TYPE RATED VOLTAGE= 120/208 VOLTS I PHASE 3 WIRE M EQPT. GRID, ED ISOL. GRID. MAINS: 13M.L.O. M BREAKER 2 3 0 FEEDER SIZE & [--]CABLE = SEE RISER I--] BUSWAY = BRANCH POLES: 12 BRANCH BREAKERS= 10 KAIC MOUNTING: 0SURFACE 0 FLUSH M FREE STANDING E:I KEYED DOOR: BUS RATING: 100A BRACING = 10 KAIC S IS: E3HALF SIZE M FULL SIZE 13 KRATED (1.5) El KRATED (2.0) GROUND BAR: M EQUIPMENT 0 ISOLATED I--] EOTH ENCLOSURE CJ NEMA 1 0 NEMA 3R 0 NEMA 4X CLASS ? DIV ? FEED LOCATION E:] TOP N BOTTOM ED REED THRU PANEL TYPE =FUSED 0 CB PLUG IN = CB BOLT IN :]NORMAL M EMERGENCY = LNINTERRUPTABLE S = SAME AS ITEM OR DEVICE AS ABOVE- SPECIAL NOTES: ELECTRICAL DETAILS SCALE: NONE T4AE, INC. - ARCHITECTURE & PLANNING 1AA26001228 & AR92559 (954)839-4258 233 EAST ACRE DR., PLANTATION, FL 33317 STRUCTURAL AND MECHANICAL ENGINEER7G BASE 4 INTERNATIONAL, INC. 9858 GLADES ROAD, �37 BASE4CA RATON, FLORIDA 33434 '1'.0720.72BASE4 ELECTRICAL 7NGINEERIN�G WEST M BEACH, FLORIDA 33406 PHONE 551 436 9198 CERT OFAUTH.: #8800 T4AE, INC., AND ALL PROFESSIONALS OF RECORD, HEREBY RESERVE THEIR INDIVIDUAL AND COLLECTIVE COMMON LAW COPYRIGHT AND ALL OTHER PROPERTY RIGHTS IN THESE DESIGNS, SPECIFICATIONS, PLANS AND IDEAS. THIS DOCUMENT IS NOT TO BE REPRODUCED WITHOUT FIRST OBTAINING THE WRITTEN PERMISSION OF T4AE, INC., AND THE PROFESSIONALS OF RECORD. ANY DISCREPANCY BETWEEN THIS DOCUMENT AND ACTUAL CONDITIONS SHALL BE REPORTED TO T4AE, INC. 0 F E S 5 1 0 N A L 0 F R E C 0 R D S E A L ��jj I I I I III, ...... ...... No. 75256 STATE OF DEVEREN PETERKIN, PROFESSIONAL ENGINEER NO. 75256 If THIS IS A CONFIDENTIAL DOCUMENT 11 THIS DOCUMENT, AND THE INFORMATION DEPICTED HEREIN, PERTAINS TO A SECURE FACILITY DESIGNATED BY THE HOMELAND SECURITY ADMINISTRATION AS CRITICAL INFRASTRUCTURE" AND MAY NOT BE SHARED WITH ANY PERSONS OR ENTITIES OTHER THAN AUTHORITIES HAVING JURISDICTION WITHOUT WRITTEN CONSENT OF THE OWNER. ANY PERSON OR ENTITY IN POSSESSION OF THIS DOCUMENT SHALL SAFEGUARD IT, AND SHALL ESTROY IT WHEN IT IS NO LONGER IN USE FOR -I ILL 0 z D F_ 0 z 0 Lij U- F_ U) z z ::) < (1) LLj 0 < (.)0 z Lij !2 F_ U) z)- 0 < _j 0 . Lu F_ F- F- (1) 0 U) R E V I S [ 0 N S IIREV #1 DATE I REVISIONS MADE 11 DRAWING SCALE T JOB NUMBER AS NOTED I B4-84-1501 MAINT. SHED PANEL SCH - ^ r%nt6�ia S SHEET NUMBCIII!f_ hRIWUBMITTAL DATE I E5.1 4/12/17