Loading...
HomeMy WebLinkAboutLIGHTING PROTECTION PLANENCLOSED AREA 3 STRANDS BARBED WIRE CABLE TO PIPE CONNECTOR WIRE TIES #1 /0 AWG TENSION WIRE - (TOP & BOTT.) CABLE TO PIPE CONNECTOR GRADE I EXTENSION ARM (45- TYPE) C—RINGS CHAIN LINK FABRIC SLOPE TO DRAIN 11 \- #1 /0 AWG 3/4" X 10' FENCE COUNTERPOISE GROUND ROD ��l ji GROUNDING DETAIL 24" FENCE COUNTERPOISE #1/0 AWG CABLE 3/4" X 10'— GROUND ROD GRADE 18" #1 /0 AWG CABLE TAP TO FENCE POST OTHERMIC WELD NOT DRIVE GROUND ROD FOR EVERY 100 FEET OF FENCE. GROUND ROD IETAIL CONCRETE COVER WITH CENTER HOLE 7" 10" MIN 7" CRUSHED STONE i-- GRADE o OiA-VOM ft- 12" 0 0 . 14 0: 1 1� CRUSHED STONE #1 /0 AWG TO FENCE COUNTERPOISE— #1/0 AWG TO LIGHTNING E PROTECTION COUNTERPOIS #500 MCM TO NEXT TWO GROUND WELLS. COPPER CLAD STEEL GROUND ROD 3/4"x2O' LIGHTNING SCALE: NONE PROTECTION PLAN -CQ3�� 0 YR 11 oo 5 �o /, 05<1 8" MIN>/ �\V�/ ;9" 1\3 24" >— GROUND CONNECTOR, FEED THRU TYPE EXOTHERMIC WELD, TYP. #500 MCM TO GROUND BUS IN POWER ROOM #500 MCM TO GROUNDING SERVICE ELECTRODE IN XFMR PAD WINDOW. BUILDING GROUND WELL SCALE: NONE ,30" BRAID TO PIPE CONNECTOR FLEXIBLE COPPER BRAID (200 AMP MIN.) FINISHED GRADE ALL FENCE GATES FENCE GROUNDING SCALE: NONE SEE 'SECURITY ON SHEET E5,2 LIGHTING MAST LIGHT' DETAIL FOR DETAIL OF ON LIGHT POLE CABLE TO PIPE CONNECTOR 12" LIC) #1 /0 A WG CABLETO FENCE COUNTERPOISE AND GROUND ROD FINISHED GRADE FENCE POSTS AT GROUND ROD LOCATIONS /74PL- T4AE, INC., ARCHITECTURE 1, PLANNING AA26001228 & AR92559 (954)839-4258 233 EAST ACRE DR., PLANTATION, FIL 33317 STRUCTURAL AND MECHANICAL ENCINEERIN3 BASE 4 INTERNATIONAL, INC. W58GLADES ROAD,#237 BOCA RATON FLORIDA33434 BASE4 1.720 72BASE4 base4.wm ELECTRICAL ENGINEERING �IN I. WY #0 WEST PALM BEACiE FLORIDA 33405 v PHONE: 561436 9198 CERT. OF AUTH.: #8800 14AE, INC., AND ALL PROFESSIONALS OF RECORD, HEREBY RESERVE THEIR INDIVIDUAL AND COLLECTIVE COMMON LAW COPYRIGHT AND ALL OTHER PROPERTY RIGHTS IN THESE DESIGNS, SPECIFICATIONS, PLANS AND IDEAS. THIS DOCUMENT IS NOT TO BE REPRODUCED WITHOUT FIRST OBTAINING THE WRITTEN PERMISSION OF T4AE, INC., AND THE PROFESSIONALS OF RECORD. ANY DISCREPANCY BETWEEN THIS DOCUMENT AND ACTUAL CONDITIONS SHALL BE REPORTED TO T4AF INC. P R 0 F E S S 1 0 N A L 0 F R E C 0 R D S E A L No.75= STATE OF AXORIVI DEVEREN PETERKIN, PROFESSIONAL ENGINEER NO. 75256 THIS IS A CONFIDENTIAL DOCUMENT THIS DOCUMENT, AND THE INFORMATION DEPICTED HEREIN, PERTAINS TO A SECURE FACILITY DESIGNATED BY THE HOMELAND SECURITY ADMINISTRATION AS "CRITICAL INFRASTRUCTURE" AND MAY NOT BE SHARED WITH ANY PERSONS OR ENTITIES OTHER THAN AUTHORITIES HAVING JURISDICTION WITHOUT WRITTEN CONSENT OF THE OWNER. ANY PERSON OR ENTITY IN POSSESSION OF THIS DCCUMFNT SHALL SAFEGUARD IT, AND SHALL DESTROY T WHEN IT IS NO LONGER IN USE FJR THE PURPOSE FOR WHICH IT WAS PROVIDED. -j 0 z D F— 0 z 0 F— 30 0 Llj LL U) 0 z z D 0 z uj 0 I-- U) Q D < Of < 0 LU F— < D < 0 U) oll CN 04 Mao limA. R E V I S 1 0 N S REV # DATE REVISIONS MADE -DRAWING SCALE JOB NUMBER AS NOTED 34-84-1501 LIGHTNING PROTECTION - -�u SHEET NUMBER -Wt TAITTAL DATE E4.1 4/12/17