Loading...
HomeMy WebLinkAboutPROJECT INFORMATIONI wrightsofto Right -Suite@ Universal 2015 Short Form UNIT 1 QUICK CALCS, INC. I 1 1 317 ST LUCIE LN., FT PIERCE, FL 34946 Phone: 772-466-6799 Fax: 772-466-6796 Email: QUICKCALCS@AOL.COM I Job: Date- Mar28,2016 By: For: A-1 TRUSS COMPANY 4451 ST. LUCIE BLVD., FT. PIERCE, FL Htg Cig Htg CIg Outside db (OF) 42 90 Inside db (OF) 70 75 Outside RH N - 59 Inside RH N - 50 Outside wb (OF) - 78 Inside wb (OF) - 63 Daily range (OF) - 15 Design TD (OF) 28 15 Moisture diff. (gr/lb) - 61 i Heating Equipment I' Cooling Equipment Make Model Type Efficiency Heating Input Heating Output Humidifier Leaving Air Temp Actual Heating Fan [NAME Elecistrip 100 EFF 17.5 kW 59.9 MBtuh 18.7 gpd 83.6 OF 4000 cfm Equipmenit Location System Type I. Fan Motor Heat Type Fan & Motor Combined Efficiency Static P, ressure Across Fan Make Model Type COP/EER/SEER Sensible Cooling Latent Cooling Total Cooling Leaving Air Temp Actual Cooling Fan UNIT 1 PEAKCV PACKAGE 0 % 0 in H20 Area Heat Sensible Latent ft2 � I Loss I Gain I Gain Htg cfm Trane TTA120A3 Split AC 11.3 89.6 MBtuh 38.4 MBtuh 128.0 MBtuh 55.0 OF 4000 cfm Clg cfm Time Jul 1600 LDT Jul 1600 LDT Jul 1600 LDT Jul 1600 LDT Jul 1600 LDT Jul 1600 LDT Jul 1600 LDT Jul 1600 LDT Jul 1600 LDT Jul 1600 LDT Jul 1600 LDT Jul 1600 LDT Jul 1600 LDT Jul 1600 LDT Jul 1600 LDT Jul 1600 LDT Jul 1600 LDT Jul 1600 LDT r OPEN EORKAREA 114 521 1440 596 0,+ 'Jul low Lu 2016-Apr-17 12:09:49 wrightSoft Right-!�6ite@ universal 2015 15.0.19 RSU08101 Page I ... Documents\Wrightsoft HVAC\A-1 TF i �USS COMPAW.rup Calc = CLTD Front Door faces: N EVP OFFICE 238 4051 4753 752 CONTROLLER 156 1852 2149 546 OFFICE 99 1379 1716 448 OFFICE 2 99 1379 1716 448 WOMENS 88 1749 1052 221 MENS 88 969 772 221 CONFERENCE 121 1849 4773 1578 ENTRY VEST 162 12964 12836 4166 STAIR 288 3973 8658 722 FOYER 312 1426 1955 782 Roomll 28 128 175 70 HALLWAY. 343 2704 2968 860 OFFICE 3 132 603 1614 1244 OFFICE 4 120 548 1556 1244 OFFICE 5 132 1528 2164 1244 WALKWAY 234 1069 1466 587 OPEN WORK 152 695 1678 691 OPEN AREA 114 521 1440 596 28', 9( 9( 12! 61 131 82 27 8� 17 3 3 10 6 4 3 21( 91, 7( 7( 7' 31 221 67! 5(� 81 13 7 6! 10, 6 7 6 WORK 49 1 224 670 278 13 30 Jul 1600 LDT OPEN 49 224 552 278 13 24 Jul 1600 LDT AREA 42 11'92 626 260 11 28 Jul 1600 LDT ASST. DESING MAN. 132 1899 3317 486 133 161 Jul 1600 LDT MANAGER 196 3,420 4075 646 243 180 Jul 1600 LDT .DESIGN OPEN WORK AREA. 144 2P23 2548 761 156 116 Jul 1600 LDT Room26 56 1 b4l 997 140 74 45 Jul 1600 LDT OPEN WORK. 144 658 �315 1642 761 38 73 Jul 1600 LDT HALLWAY 69 432 173 18 19 Jul 1600 LDT OPEN WORK AR. 144 23,15 3600 2489 157 159 Jul 1600 LDT OPEN AREA. 144 1671 1684 761 39 74 Jul 1600 LDT HALL 196 1 789 1686 491 119 80 Jul 1600 LDT HALL. 174 2851 1827 436 202 134 Jul 1600 LDT Room35 91 414 2077 1247 24 92 Jul 1600 LDT Room36 64 1 812 1237 160 132 76 Jul 1600 LDT I UNIT 1 1 4714 1 159877 1 81852 1 26382 1 40001 40001 Jul 1600 LDT I wrightsoft Right -Suite@ Universal 2015 15.0.19 RSU08101 I ... DocumentsWrightsoft HVAC\A-1 TRUSS COMPAW.rup Calc = CLTD Front Door faces: N 2016-Apr-17 12:09:49 Page 2 Right -Suite@ Universal 2015 Short Form Job: wrightsofto Date: Mar 28, 2016 UNIT2 Ely - QUICK CALCS, INC. 317 ST LUCIE LN., FT PIERCE, FL 34946 Phone: 772-466-6799 Fax: 77 -,466-6796 Ernail: QUICKCALCS@AOL.COM For: A-1 TRUSS COMPANY 4451 ST. LUCIE BLVD., FT. PIERCE, FL Htg Clg Outside db (OF) 42 90 Outside RH (0/0 - 59 Outside wb (OF) - 78 Daily range (OF) - 15 Moisture diff. (gr/lb) - 61 Heating Equipment Make Model Type Efficiency Heating Input Heating Output Humidifier Lea�4ng Air Temp Actual Heating Fan Elec strip 100 EFT 159 kW 5414 MBtuh 1�.9 gpd 82.4 OF 40100 cfm Efluipment Loltion System Type I Fan Motor Heat Type Fan & Motor Combined Efficiency Static Pressure Across Fan Htg CIg Inside db (OF) 70 75 Inside RH N - 50 Inside wb (OF) - 63 Design TD (OF) 28 15 Cooling Equipment Make Trane Model TTA120A3 Type Split AC COP/EER/SEER 11.3 Sensible Cooling 89.6 MBtuh Latent Cooling 38.4 MBtuh Total Cooling 128.0 MBtuh Lea�ting Air Temp 55.0 OF Actual Cooling Fan 4000 cfm UNIT 2 PEAKCV PACKAGE 0 % 0 in H20 NAME Area ft2 H eat Loss Sensible Gain Latent Gain Htg cfm Cig cfm Time FUTURE OFFICES 1212 15868 30487 5177 1175 1086 Jul 1600 LDT MENS. 88 1189 1457 221 88 53 Jul 1600 LDT WOMENS. 88 1886 1807 221 145 76 Jul 1600 LDT Room43 1904 23014 41944 7866 1691 1494 Jul 1600 LDT CONFERENCE ROOM 504 3101 15041 8233 206 536 Jul 1600 LDT VEST. 166 1034 2133 421 69 77 Jul 1600 LDT OPEN TO BELOW 5014 1 8313 1 17108 1 1263 1 627 1 679 1 Jul 1600 LDT UNIT 2 I 44q8 _54405 109977 23402 1 40001- 40001 Jul 1600 LDT wrightsoft' Right -Suite@) Universal 2015 15.0.19 RSU08101 i ... Docunients\Wrightsoft HVAC\A-1 TRUSS COMPAW,.rup Calc = CLTD Front Door faces: N 2016-Apr-17 12:09:49 Page 3 7 Right -Suite@ Universal 12015 Load Summary Job: Date: Mar28,2016 wrightsofto UNIT 1 By: QUICK CALICS, INC. 31;ST. LUCIE LN., FT. PIERCE, FL 34946 Phone: 772-466-6799 Fax: 772A,66-6796 Email: QUICKCALCS@AOL.COM Project Information For: A-1 TRUSS COMPANY 4451 ST. LUCIE BLVD., FT PIERCE, FL UNIT 1 C - 00L1N_G_L0AD__________ 1. DESIGN CONDITIONS at 16010 LDT' Peak load at Jul 1600 LDT Inside: 75 OF Outsid�': 90 OF TD: 15 OF RH: 59 % Moistbiff: 61.5 gr/lb Mult: 1.0 Ins.wb 63 OF I Sensible Latent 2. SOLAR RADIATION THROUGH GLASS 12826 3. TRANSM[ISSION GAINS Sensible 10841 Walls: 5529 - - Glass: 4446 - - Doors: 0 - - Partitions: 0 - - Floors: 0 - - Ceilings: 865 - - 4. INTERNAL BEAT GAIN Sensible Latent 23933 6910 Occupants: 8730 6910 - - Lights: 15203 - Motors: 0 - Appliances: 0 0 - - 5. INFILTRATION: 0 tside air cf m: 466 7684 19472 6. SUBTOTAL: Spaceload Sensible Latent 55284 26382 Envelope 55284 26382 - - Less external 0 - Redistribution 0 0 - 7. SUPPLYDUCT 16329 8. SUBTOTAL: Space load + supply duct 71613 Actual cfm: 4000 at supply TD: 20 - - 9. VENTILATION ake-up air cfm: 0 0 0 10. , �OAD: RETURNAIR Lighting + plenum (net) r 0 - 11. RETURN DUCT 10238 - 12. TOTAL LOADS ON EQUIPMENT 81852 26382 HEATING LOAD 13. DESIGN CONDITIONSI Mult: 1.0 Inside: 70 OF Putside: 42 OF TD: 28 OF 14. TRANSMISSION LOSSE 24044 Walls: 10143 - Glass: 8586 - Doors: 0 - Partitions: 0 - Floors: 5006 - Ceilings: 309 - 15. INFILTRATION: Outside air cfm: 584 17978 16. SUBTOTAL: Space lo, ad 42021 Envelope 42021 - Less external 0 - Less transfer 0 - Redistribution 0 - 17. SUPPLYDUCT: 8635 18. VENTILATION. Make-up air cf m: 0 0 19. HUM[IDIFICATION 7069 Piping 1 0 20. RETURN DUCT 2153 21. TOTAL HEATING LOAD ON EQUIPMENT 59877 +k wrightsoft* Right -Suite@ Universal 2 ... Documents%Wrightsoft HVAC\A-1 TRUSS COMPAW.' 5 15.0.19 RSU08101 i Caic = CLTD Front Door faces: N 2016-Apr-17 12:09:49 Page I Right -Suite@ Univers�l 2015 Load Summary Job: 4+ wrightsofto Date: UNIT2 By: QUICK CALCS, INC. 317 ST LUCIE LN., FT. PIERCE, FL 34946 Phone: 772-466-6799 Fax: 772-4,66-6796 Email: QUICKCALCS@AOL.COM E Mi R1111MIR For: A-1 TRUSS COMPANY 4451 ST. LUCIE B,LVD., FT PIERCE, FL Mar28,2016 Zone: UNIT 2 C-0-01-ING-LOAD---- 1. DESIGN CONDITIONS at Jul 1600 LDT Peak load at Jul 1600 LDT Inside: 75 OF Outside:! 90 OF TD: 15 OF RH: 59 % MoistDi f: 61.5 gr/lb Mult: 1.0 Ins.wb 63 OF Sensible Latent 2. SOLAR RADIATION THROUGH GLASS 14835 3. TRANSMISSION GAINS Sensible 26790 Walls: 4834 - - Glass: 6177 - - Doors: 0 - - Partitions: 0 - - Floors: 0 - - Ceilings: 15780' - - 4. INTERNAL HEAT GAIN Sensible Latent 26459 7700 Occupants: 8350 7700 - - Lights: 18109 - Motors: 0 - Appliances: 0 0 - - 5. INFILTRATION: Outside air cfm- 376 6196 15702 6. SUBTOTAL: Spaceload Sensible Latent 74280 23402 Envelope 74280 23402 - - Less external 0 - Redistribution 0 0 - 7. SUPPLYDUCT 21940 8. SUBTOTAL: Space load + supply duct 96221 Actual cfm: 4000 at supply TD: 20 - - 9. VENTILATION: Make-up air cf m: 0 0 0 10. RETURNAIRLOAD: 11lighting + plenum (net) 0 - 11. RETURN DUCT 1 13756 - 12. TOTAL LOADS ON EQUIPMENT 109977 23402 HEATINa-LOAD 13. DESIGN CONDITIONS Mult: 1.0 Inside: 70 OF Outside: 42 OF TD: 28 OF 14. TRANSMISSION LOSSES 27046 Walls: 9489 - Glass: 11928 - Doors: 0 - Partitions: 0 - Floors: 0 - Ceilings: 5628 - 15. INFILTRATION: utside air cfm: 402 12374 16. SUBTOTAL: Space loaltod 39420 Envelope 39420 - Less external 0 - Less transfer 0 - Redistribution 0 - 17. SUPPLYDUCT- 0 8100 0 18. VENTILATI& Make-up air cfm: 19. HUMIDIFICATION 4866 Piping 0 20. RETURN DUCT 2019 21. TOTAL HEATING LOAD ON EQUIPMENT 54405 1 2016-Apr-17 12:09:49 wrightsofV Right -Suite@ Universal 2015 1r 5.0.19 RSU08101 Page 2 ... Documents\Wrightsoft HVAMA-1 TRUSS COMPANY.rup �alc = CLTD Front Door faces: N This document was created with Win2PDF available at http://www.win2pdf.com. The unregistered version o�f Win2PDF is1for evaluation or non-commercial use only. This page will not be added after purcha I sing Win2PDF. )ject Name: A- 1 TRUSS COMTANY ProjectTitle: A-ITRUSSCOMPANY Address: 445 1 ST. LUCIE BLVD. State: FL Zip: 0 Owner: No Acronym Description I UNIT 1 Zone 1 2 UNIT 2 Zone 2 IL - EnergyGauge Summit@ v5.20 INPUT DATA REPORT Proiect Information Orientation: North -----------Building Type- Office Building Classification: New I No.of Stories: 1 GrossArea: 9183 Type CONDITIONED CONDITIONED Zones 4/17/2016 EnergyGauge Summit@ v5.20 SF Area Multiplier Total Area [sfl Isf] 4715.1 1 4715.1 4468.0 1 4468.0 Spaces No Acronym Descrip tion Type Depth Width Height Multi TotalArea Total Volume Ift] Ift] [ft] plier Isfl [cf] In Zone: UNIT 1 1 PrOZolSP1 ZoOSpl Office - Enclosed 76.05 62.00 10.00 1 4715.1 47151.0 El In on : UNIT 2 1 PrOZo2Spl ZoOSpl Office - Enclosed 80.00 55.85 10.00 1 4468.0 44680.0 Lighting �N�'I�,pe��Ca�tegory Lmm In Zone: UNIT I In Space: Pr0Zo1Sp1 1 Compact Fluorescent General Lighting 50 25 1250 Manual On/Off 2 El In Zone: UNIT 2 In Space: Pr0Zo2Sp1 1 Compact Fluorescent General Lighting 50 25 1250 Manual On/Off 2 El Walls No Description Type Width H (Effec) Multi Area Ori entation Conductance Heat Dens. R-Value [ft] [ft] plier [sf] [Btulhr. sf. F] Capacity [lb/cf] [h.sf.F/Btul [Btu/sEF] In Zone: UNIT I 1 PrOZolWal Stucco, 8" Block, 62.00 10.00 1 620.0 East 0.1110 7.751 41.32 9.0 E] R-4.1, 1/2" Gyp. 2 Pr0Zo1Wa2 Brd. Stucco, 8" Block, 62.00 10.00 1 620.0 West 0.1110 7.751 41.32 9.0 0 R-4.1, 1/2" Gyp. Brd. 4/17/2016 EnergyGauge Summit@ v5.20 2 3 PrOZolWa3 In Zone: UNIT 2 1 PrOZo2Wal 2 Pr0Zo2Wa2 3 PrOZo2Wa3 Stucco, 8" Block, 76.05 10.00 1 760.5 North 0.1110 7.751 41.32 9.o El R-4.1,1/2" Gyp. Brd. Stucco, 8" Block, 55.85 10.00 1 558.5 East 0.1110 7.751 41.32 9.0 El R-4.1, 1/2" Gyp. Brd. Stucco, 8" Block, 55.85 10.00 1 558.5 West 0.1110 7.751 41.32 g.o EJ R-4.1, 1/2" Gyp. Brd. Stucco, 8" Block, 80.00 10.00 1 800.0 North 0.1110 7.751 41.32 9. R-4.1, 1/2" Gyp. Brd. No Description Orientation Shaded U SHGC Vis.Tra W H (Effec) Multi Total AFCa [Btu/hr sf F] [ft] [ft] plier [Sfl In Zone: UNIT I In Wall: EAST 1 PrMlWalWil East No 0.9000 0.68 0.66 4.00 3.40 4 54.4 In Wall: NORTH 1 PrOZol%3Wil North No 0.9000 0.50 0.40 5.00 2.00 4 40.0 2 PrMlWaM2 North No 0.9000 0.50 0.40 2.00 5.00 4 40.0 3 PrOZol%M3 North No 1.2500 0.82 0.76 4.00 9.00 4 144.0 4 PrMlWaM4 North No 0.9000 0.68 0.66 6.00 8.00 1 48.0 5 PrMlWaM5 North No 0.9000 0.50 0.40 6.00 4.00 1 24.0 In Wall: WEST 1 PrMl%2W11 West No 0.9000 0.50 0.40 4.00 3.40 5 68.0 In Zone: UNIT 2 In Wall: EAST 1 PrM2%].Wil East No 0.9000 0.50 0.40 4.00 3.40 4 54.4 In Wall: NORTH I PrOZoMaMl North No 0.9000 0.50 0.40 8.00 8.00 4 256.0 2 PrOZo2Wa3Wi2 North No 0.9000 0.50 0.40 4.00 9.00 5 180.0 In Wall: WEST 1 PrOZoMaMil West No 0.9000 0.50 0.40 4.00 3.40 5 68.0 4/17/2016 EnergyGauge Summit@ v5-20 3 a E] Doors No Description T�pe Shaded? Width H (Effec) Multi Area Cond. Dens. Heat Cap. R-Value Ift] [ftj plier [sf] [Btu/hr. sf. F] [lb/cf] [Btu/sf. F] [h.sf.F/Btu] In Zone: In Wall: 0 Roofs Description 1),pe Width H (Effec) Multi Area Tilt Cond. Heat Cap Dens. R-Value plier [sf] [deg] [Btu/hr. SE F1 [Btu/sf. F] [lb/cf] [h.sf.F/Btul In Zone: UNIT I 1 PrOZolRfl Mtl Bldg Roof/R-19 62.00 76.05 1 4715.1 0.00 0.0492 1.34 9.44—M-3—[El- Batt In Zone: UNIT 2 20.3 0 1 PrOZo2Rfl Md. Bldg Roof/R-19 55.85 80.00 1 4468.0 0.00 0.0492 1.34 9.49 Batt Skylights No Description T�pe U SHGC Vis.Trans W H(Effec) Multiplier Area TotalArea [Btu/hr sf F] Ift] Ift] Isf] Isf] In Zone: In Roof: El Floors No Description T�pe Width H OEffec) Multi Area Cond. Heat Cap. Dens. R-Value Ift] [ftj plier Lsf] [Btu/hr. sf. F] [Btu/sf. F] [lb/cf] [h.sf.F/Btu] In Zone: UNIT 1 4/1712016 EnergyGauge Summit@ v5.20 I PrOZolF11 1 ft. soil, concrete floor, carpet and rubber pad In Zone: UNIT 2 1 PrOZoMl 1 ft. soil, concrete floor, carpet and rubber vad 62.00 76.05 1 4715.1 0.2681 34.00 113.33 3.73 55.85 80.00 . 1 4468.0 0.2681 34.00 113.33 3.73 Systems PrOSyl System I Constant Volume Packaged System No. Of Units 1 Component Capacity Efficiency IPLv I 2 3 Cooling System Heating System Air Handling System -Supply 12800CFOO-1-1-30 50000.00 4000.00 11.40 1.00 0.80 13 E] PrOSy2 System 2 Constant Volume Packaged System No. Of Units 1 Component Category Capacity Efficiency IPLv 1 2 3 Cooling System Heating System Air Handling System -Supply 128000.00 50000.00 4000.00 11.30 11.40 1.00 0.80 1-1 Plant Equipment Category Size Inst.No Eff. IPLv Li Water Heaters W-Heater Description Capacit3Cap.Unit I/P Rt. Efficiency Loss EU 4/17/2016 EnergyGauge Summit@ v5-20 5 EA -Lighting Description Category No. of Watts per Area/Len/No. of units Luminaires Luminaire [sVft/No] Control Type Wattage [w] El Piping No Type Operating Insulation Temperature Conductivity [F] Btu-in/b.sf.F] Nomonal pipe Diameter [in] Insulation Is Runout? Thickness [in] El Fenestration Used Name Glass Type No. of Panes Glass Conductance [Btuth.sLF] SHGC VLT ASHULSgICIrAl User Defined 1 1.2500 0.8200 0.7600 0 IFrm ASHULDbICIrM User Defined 2 0.9000 0.6800 0.6600 E] fl-Oth frm ASHULDbITntM User Defined 2 0.9000 0.5000 0.4000 El d-Oth frm Materials Used Mat No Acronym Description Only R-Value RValue T . hickness Conductivity Density SpecificHea. Used [h.sLF/Btu] Ift] [Btu/h.ft.Fl [lb/cf] t 4/17/2016 EnergyGauge Summit@ v5.20 6 I a 187 Matl 187 178 MatI178 265 Mat1265 48 Mat148 123 MatI123 267 Mat1267 23 Mat:123 11 Matl11 94 Mat:194 No Name GYP OR PLAS No BOARD,1/21N CARPET W/RUBBER PAD Yes Soil, I ft No 6 in. Heavyweight concrete No CONC BLOCK No MW,81N,HOLLOW 0.75" stucco No 6 in. Insulation No 2 in. Insulation No BUILT-UP ROOFING, 3/81N No 0.4533 0.0417 1.2300 2.0000 1.0000 0.5000 0.5000 1.7227 0.6667 0.1563 0.0625 20.0000 0.5000 6.6800 0.1670 0.3366 0.0313 ids Used 0.0920 50.00 0. 4 2000 0.5000 100.00 0.2000 El 1.0000 140.00 0.2000 El 0.3870 53.00 0.2000 El 0.4000 16.00 0.2000 E] 0.0250 5.70 0.2000 El 0.0250 2.00 0.2000 D 0.0930 70.00 0.3500 0 ensity RValue lb/cf] ["f.F/]3tul--- 1056 x/fdRid Rnof/R-1013att No No 0.05 1.34 9.49 20.3 Simple Massless Conductance Construct Construct LBtu/h.sf.F] 45 Layer Material Material Thickness Framing No. [ft] Factor 1 94 BUILT-UP ROOFING, 3/8IN 0.0313 0.000 E] 2 23 6 in. Insulation 0.5000 0.000 E] Simple Massless Conductance Heat Capacity Density RValue No Name Construct Construct [Btu/h.sf.F] [Btu/sf.F] [lb/cf] [h.sf.F/Btul 1057 1 ft. soil, concrete floor, carpet and rubber No No 0.27 34.00 113.33 3.7 pad Layer Material Material Thickness Framing No. [ft] Factor 1 265 Soil, 1 ft 1.0000 0.000 2 48 6 in. Heavyweight concrete 0.5000 0.000 3 178 CARPET W/RUBBER PAD 0.000 4/17/2016 EnergyGauge Summit@ v5.20 7 M No Name Simple Massless Conductance Heat Capacity Construct Construct [Btu/h.sf.Fl [Btu/sf.Fl Density RValue [lb/cf] [h.sf.F/Btul 1060 Stucco, 8" Block, R-4.1, 1/2" Gyp. Brd. No No 0.11 7.75 41.32 9.0 Layer Material No. Material Thickness Framing [ft] Factor 1 187 GYP OR PLAS BOARD, 1/21N 0.0417 0.000 El 2 123 CONC BLOCK MW,81N,HOLLOW 0.6667 0.000 E:1 3 267 0.75" stucco 0.0625 0.000 El ---`11-2-in--Jnsulation 4 0.1670 0.000 4/17/2016 EnergyGauge Summit@ v5-20 8 This document was created with Win2PDF available at http://www.win2pdf.com. / The unregistered version of Win2PDF is for evaluation or non-commercial use only. This page will not be added after purchasing Win2PDF. a