Loading...
HomeMy WebLinkAboutCERTIFICATION FOR DESIGN LOAD COMPLIANCEPlanning & Development Services Department I COUNTY Building & Code Regulations Division F L 0 R I D Fk ]�� i 2300 Virginia Avenue, Fort Pierce, FL 34982 — (772) 462-1553 Certification for De� , sign Load Compliance SCANNO i BY Project Name: AcquaVista Lot 2 - Single Family F16sidence q wip N04 I Project Address: 4416 North Al A (Hutchinson Island); Fort Pierce, Florida 34949 (St. Lucie Co.) Permit #: Occupancy I Type: R-3 Construction Type: Type Vb — INSTRUCTIONS FOR USE: * This certification must be completed, signed, and * Submit (2) copies for residential, (3) copies for co • New Residences (single or multi -family) • Residential Addition • Any accessory structure requiring a bullc • Any non-residential structure * * Note: Form not required for interior renovations P� certain minor building permits at the discretion of the mled by the design professional of record. mercial with all permit appliptfonst;vq0 ing permit ovided that no exterior stri JAN 2 5 2019 I ucle Cooty, Permitt(rig irtimil PlPrnPnts are affected anc local building official. Contact the # above for questions. DESIGN PARAMETERS AND ASSUMPTIONS USED: (co plete all that apply) 1. DESIGNCODE: Florida Building —CodeFi hEditionwith20 17 supplements using ASCE 7-10 2. Structure Designed as (check one): Enclose Partially Enclosed —Open 3. Risk Category: _I X 11 111 IV Exposure Category: _B —C X D 4. Design Wind Velocity .170Vult mph X ASID LRFD End Zone Width: 5.1 ft 5. Mean Roof Height 30' ft Roof Pitch: 4.5 :12 Parapet: N/A ft 1 3 0 ' 6. Components & Cladding Design Pressures Used: (PSF, based on 10sqft @ Z'MRH, clearly label on all plan openings): I Zone 1: -47.4 Zone 2: -82.4 Zone 3: -P2.4 Zone 4:-56-1 Zone 5: -69.3 Garage: -52.1 7. Design Loads: Floor: 55 PSF Roof/De'ad: 25 PSF Roof/Live: 20 Balcony: 16o PSF Dock: N/A PSF Deck: 100 PSF Stairsi 60 PSF Fence: N/A PSF Railings: 200 PSF 8. Were Shear Walls Considered For Structure? IX Yes Not Applicable Explain Why Not: 9. Is A Continuous Load Path Provided? X Yes Not Applicable - Explain Why Not: I — . . 10. Design Soil Bearing Pressure: - 2500 PSFJ Soil Test Reports Submitted? X Yes I DESIGN PROFESSIONAL CERTIFICATION STATEMENT: I certify that, to the best of my knowledge and 6elief, the attached plans & specifications have been designed to comply with the applicable structural portions q I f the building codes currently adopted and enforced by St. Lucie County. I also certify that structural elements d i �picted on these plans provide adequate resistance to the design forces specified: I Dayid S. Knight, P.E. 41060 Prini Name Cert # & Co. Cert Auth. Kni i ght McGuire & Associates, Inc. gnature, Date, and Seal 801Royal Palm Pointe Suite 401; Vero Beach, FL 32960 Co pany Name & Addres % Revised 07/25/2014 F I L 0 P T