HomeMy WebLinkAboutDRAWING FOUNDATION FLOOD VENTpz
(3
t�
FRAME
FIGURE 2
SIDE VIEW
GRIP &
.00ATION
DETAIL DIAGRAM
MODEL 1540-520
FLOOD VENT INSULATED
SCANNED,
BY
st Lole'-,Annfi
ANDBRO DR UNIT 1
PITMAN NJ 09071
SMART VENTo
877-441-8368 FLOOD VENT INSULATED
WWW.SMARTVENT.COM MODEL 1540-520
SIZE I DWG N
A 1540-520
MTr 9-91-ir I QuCrT . - .
RE
E
Smart VENT
877— 441 — 8368
tvww.smartvent.com
INSTALLATION INSTRUCTIONS
& DETAJLS
MODEL 1540-520
FLOODVENT INSULATED
ML "As
1. REMOVE VENT DOOR FROM VENT FRAME. (TURN UPSIDE DOWN, ROTATE BOTTOM OF DOOR OUTWARD AND SLIDE OUT)
2. PREPARE A CLEAN 16.25" WIDE BY 8.25" HIGH ROUGH OPENING (APPROX. 1 BLOCK WIDE X 1 BLOCK HIGH) FOR EACH VENT. ENSURE THE BOTTOM OF THE- ROUGH OPENING IS NO MORE
THAN 12" ABOVE THE FINISHED GRADE.
3. APPLY A BEAD OF HURRIBOND GRIP & SEAL OR EQUIVALENT ADHESIVE AROUND THE BACK OF THE FLANGE ON THE VENT FRAME. (FIG. 2)
4. INSERT INSTALLATION CLIPS INTO THE TWO SLOTS ON THE"TOP AND TWO SLOTS ON THE BOTTOM OF THE FRAME.
5. THE SPRING ARM OF THE CLIPS SHOULD BE ON THE OUTSIDE OF THE VENT FRAME.
COMPRESS THE'BOTTOM IWO CUPS AND BEGIN SUPPING THE FRAME INTO THE OPENING. ENSURE THAT THE BOTTOM CLIPS ARE IN THE OPENING BEFORE ALLOW'THEM TO DECOMPRESS.
6. WITH THE FRAME NOW IN THE OPENING. AND THE BOTTOM SPRINGS IN PLACE, COMPRESS THE TOP SPRINGS AND PUSH THE VENT FRAME INTO THE OPENING
COMPLETELY UNTIL THE FRAME IS FLUSH WITH THE WALL
7. RE -CHECK THAT FRAME IS SQUARE AND SLOTS ARE CLEAR OF DEBRIS, AND CAULK.
8. INSTALL THE DOOR INTO FRAME BY GRASPING THE BOTTOM OF DOOR (WITH FLOAT PINS DOWN) AND FRONT (SMALL SCREEN IN FRONT). SLIDE DOOR INTO FRAME AND
ROTATE UNTIL IT IS LATCHED.
9. TO OPEN THE DOOR INSERT TWO CREDIT CARDS INTO THE FLOAT SLOTS AS SHOWN IN THE DIAGRAM. THIS WILL UNLATCH THE DOOR FOR REMOVAL AND CLEANING.
DETAIL SPECIFICATIONS:
MATERIAL STAINLESS STEEL
OPERATION: AUTOMATIC NON -POWERED ACTIVATION AND OPERATION
INSTALLATION:
. SECURED W/ 4 STAINLESS STEEL INSTALLATION CUPS INCLUDED AND AN ADHESIVE
.HYDROSTATIC RELIEF. 200 SO. FT PER VENT
REQUIREMENTS: MINIMUM OF 2 VENTS PER ENCLOSED AREA MOUNTED ON AT LEAST TWO DIFFERENT WALLS
COLORS: STAINLESS (STANDARD)
EXTERIOR POWDER COATED WHITE. WHEAT, GRAY. AND BLACK (AVAILABLE)
MEETS THE REQUIREMENTS FOR ENGINEERED OPENINGS AS SET FORTH BY:
FEMA, NFIP, ICC, & ASCE
SUPPORTIVE DOCUMENTS. TB 1-08, 44CFR 60.3(C)(5). ASCE 24-14
ICC EVALUATION # ESR-2074