HomeMy WebLinkAboutELEVATOR SPECIFICATIONSPALM BFACgLIFTS, P1 j .— Wi 1748 Australian A� enue North, Suite 14, � � Riviera Beac , Florida 33404ERECMVED (561) 863-7707Fax (561) 863-7799 2 0 1019 unt Y, Permitting ACQUAVISTA Lot 7 I Quantity: Type: Capacity: Speed: Travel: Landings: Openings: Control: Pit: Power Supply: Overhead: Lighting Supply: Operation: Machine Room Location: Car Size: Power Doors: Pump Type: Special Conditions: ELEVATOR SPECIFACTION 2 stage DP 100ibs 0 fpm 4' ay Logic 2' 220. V.A.C., 30 amp, single phase w/neutral 10, 110 V.A.C., 15 amp, single phase Automatic Botton adj 47'x54"x94"ID Optional EECO 5HP Base cab is cabinet grade plywood veneer, high hat ceiling fixture, stainless fixtures, vinyl woodfold gate, finish floor by others.. Installation shall comply with ASCE 24-05 umlp unit electrical and control elevated above flood level. 1 I I I I 7 11 I I l I I I I I I i I ,I Q Permanent power to operate the elevator m machine room/area is to be provided by the Beach Lifts, Inc. specifications. If temporary the owner/agent's responsibility'to provide Due to the desirable battery backul that the following disconnect, or its Siemans (or comparable quality,' SMNS HF221 N D SMNS HA161234 auxiliary c SMNS HR21 rejection clip ki Without an auxiliary contact in disci be removed properly when disconn 2. Where applicable; tow sleeves, thre conduit and hydraulic hose from the also shall be provided by the owner 3. No conduit wiring and piping other 1 hoistway. 4. Due to close running clearance, the plumb, square and true to dimensic 5. It is the sole responsibility of the ovt fastenings and. a shaft which will sa 6. The pit floor is to be provided by ovi Inc. 7. Pit must be clean, dry and level. Pi owner/agent. 8. Any changes to overhead must be equipment. 9. Pit walls must be in line with rail an( shall be under the cut-out area desi 10. Where applicable, front wall hoistw� installed. Entrance frames are to b( masonry around doors is the respor 11.. Call buttons must be inserted in the responsibility of the owner/agent. 12. Palm Beach Lifts, Inc, highly recomi will not be responsible for doors wai the responsibility of the owner/agent 13. Residential elevator code states the comply with these rules: R321 CH LIFTS, INC: 3Y OTHERS) ast be provided to a lockable fused disconnect. A owner/agent before installation begins, per Palm power is provided to expedite the installation, it is Jequate power. urei' that our controllers offer, it is highly recommended I, be used: (RKS f'type fuse) nnectj as listed above, emergency lowering voltage cannot ct is turned off. inches in diameter; are to 'be provided for the electrical, machine room to the hoistway. If trenching is needed this to the lift equipment is permitted in the Br/agent must assure that the hoistway is constructed ; specified Palm Beach Lifts, Inc. gent to provide adequate support,for guide rail upport all loads imposed by lift equipment. gent to support a load as specified by Palm Beach Lifts., proofing or sump, if required, is to be provided by by Palm -Beach Lifts, Inc. prior to ordering �oistway walls. Where applicable, no footing or obstruction sated for cylinder installation. is to be left at the lowest level until the car enclosure is. ,rected after the elevator is installed. Finish grouting and. bility,of the owner/agent. all. The drywall and painting after installation is the s the installation of solid -core doors at each landing and and repairs caused by their warping. Door hardware is owing rules, and the layout of the hoistway doors must 14. A telephone line shall be provided Jri the. machine room and located near the elevator control, panel. far 51zincj for 2 5top Elevator Back Wall Application Clear hoistway 1 41! . Car Frame ail System requires a 24" or cleep,er pit i ar' frame _ 2" Ln o = - Cle r inside dimension bo ba5ed on hoi5tway Uoverhead dimension. Accordion gat I 32" �inimu 3" minimum ! 10" minimum. Kit Contaim. 1" p 1- B, .4® t Z_ 11 2-11 EMDL I ^614" Set Back Plate Kit " , I porta: EMDL L.H. Door Locks Note: If Hoisbvay'Door is*Iess than 1-3/4" thick additional i/8" spacers are requited on Hall side of plate. Addilional spacers aroj�'old separately. Part Nuniber. EMOL7505P I WARNING: The installation of this dev technician that has a fell u only be performed by a professional elevator rig of this device's operation .and function. Note: If there is any doubt regarding the installation procedures, please call the factory for assistance. N1le are available M-F 8:00,am to 5:00:pm Central Time. WARNING: Failure to. comply with ail 6 nstructions and " WARNING"(s) can :result in a safety system compromise. This .fin tear , can result in:serious injury or death. Pre -Installation: 1. Fully read and understand all instructions and warnings. 2. This kit is to only beused with the Ponta EMDL,series 3. This kit is intended for 1 % thick solid core hoistway�doors > If your, door is less than 'I I/V thick spacers must be added to the hall side of the door to make-up the difference. 118" thick spac6r, , (P.[ 1 EMDL750SP) are sold separately. The spacers are not hand dependant, 4. These instructions -are to be used in conjunction with he.ldck installation instructions. Plate Kit Installation: 1) The. lock- must be mounted on the knob/latch side ofthe door. 2) Determine lock height The dock will accept a multi -conductor cable from the back or'/z" conduit from the top. 3) The lock requires a flat mounting surface. Remove12-5116" of doorstop trim 0ambzide).at the desired lock location. 4) From inside the hoistway, secure the template provided'to the lock mounting surface and door, 5) Drill holes per the template instructions. WARNING: DO NGT.ATTE.MPT TO INSTALL: PLATE KIT WITHOUT USING THE TEMPLATE. 6) Mount plate and backing. spacer to door 7) Trace inside line of backing spacer to door 8) Remove plate and backing spacer 9) Cut door along traced. outline 10) Attach Keeper to Hoistway. side of plate with two.1 11) Lock Keeper in..piace using two 10-32 atom nuts. 12) Mount plate and backing spacer to door 13) Mount the door lock to the jamb using two #10 x 1 1�) From the.hoistway side, close the door and variiy a) Adjust the lock and or keeper as necessary s ' sYii Ls7 s .111+T01W* 15) Refer to `Ponta Electric Door Lock Installations insi x 7/16" flat head screws pan head screws you can release the latch manually.. THE KEEPER"' items 9-16 to complete the installation I ***WARNING*** All inspections, maintenance; repairs and replacernents should be performed by elevator personnel only. ��WARNING*** i Po)I°ta Inc. Phone: (847) 593-4900 250 Hamilton Rd. Fax: (847) 5934394 Arlington Heights, IL 60006 website: www.emiporth.com PALM REA4PH LIFTS, INC. 1748 Australian,Avenue North,. Suite 14 RiViera Beach, FL-,33404 (5610 863-7707 Fax (561) 863-7799 DISCONNECT Due to the desirable battery ;b is highly recommended that:t] used: Siemans (or comparable quality) SMNS HF221N 'D SMNS lIA161134 auxiliary conta SMNS HR21 rejection clip kit ((l Without an auxiliary contact; in lowering; voltage cannot be ran off. POWER SUPPLY 30 amp service 220/240 V single phase Ground. and. Neutral Separate 110 vac light c TELEPHONE Telephone line wired to a If phone line is not wired marked feature that our controllers offer, it )wing disconnect, or its equal be fuse) nnect, as listed above, emergency properly when disconnect is turned cab lighting (recommended) Ord, female jack preferable standard female jack, wires must be GENERAL LIGHTING General lighting of the machine room space with. a lighting switch made easily accessible should be prc vided to aid serviceability of equipment in the future 1 -0 1. 21-611 - I 0 (2) 2 x 10 glued and screwed, supported and fastened between (2) 2 x 4 behind plywood for supporting rail brackets. All supports should, be STRAPPED to slabs, joists, and trusses. Typical stud and We board construction. 0 rail EDUCATIONAL PRODUCT Lifts Construction The maximum distance between the inside face of the holstway door and the holstway sill is 3". The maximum distance between the Inside face of the holstway door and the car gate is V. Palm Be'aGhj Lifts i two SIOP rail sv'ste m, I Fasteners to be 1/211 x 3" sleeve anchors in poured block or 1/2" x 3" wood lags in wood backing. bracket through bolts