Product Review Affidavit
Owners Name Lot 02 Aqcuavista
Applicant:
Product
Opening Design
Pressures
Product Rated
Design Pressure
Manufacturer
Model Number
Product Approval
Number
Glass
Type
Method of Attachment
Windows
+52/-70 psf
+70/-82 psf
Lawson
3200
NOA 17-1212.22
B
1/4" TAPCON
Mullions
+51/-65 psf
+65/-65 psf
Lawson
Clipped Tube Mull
NOA 18-0529.03
n/a
5/16" TAPCON
Fixed Glass
+51/-65 psf
+68/-68 psf
Lawson
4200/6200
NOA 17-1212.13
B
1/4" TAPCON
Block Glass
n/a
Skylights
n/a
Sliding Glass Doors
+46/-57 psf
+60/-60 psf
SIW
600 KM-12
FL 18321
A
1/4" ELCO ULTRACON
Swing Type Doors
+46/-57 psf
+80/-80 psf
SIW
500-9
NOA 17-1115.01
B
1/4" ELCO ULTRACON
French Doors
+46/-57 psf
+86/-86 psf
Lawson
La Porte
NOA 18-0503.06
B
5/16" TAPCON
Garage Doors
--+56T-64-p-S-f-----CFAB--HUR"S-T"-24/&W-NOA4-5-0304-02--nla—
5/16" x 1 5/8" HEX HEAD LAG SCREW@ EA BRACKET
+47/-60ps
Hurricane Protection
n/a
flation
n/a
Rd�.aterlal
ke ns 07/22/2014
,-- 5Pr reviewed the above components or cladding and I have approved their use in this structure. These products provide adequate resistance to the
inads and forces specified by current code provisions. r m�
Kzl�' Randali Stofft
N164 Signature*,--YXA-Y�1)85J seal
"7,9
I gj rj
Architect FL-001 1105 3/12/2019 1 U
Weli9vo Prof Cert. NO. Date: Oulu
wm
610" 0 V,