Loading...
HomeMy WebLinkAboutTRUSS 1-25-19Lumber design values are in accordance with ANSI/TPI 1 section 6.3 These truss designs rely on lumber values established by others. MiTek" RE: 75575 - ACQUAVISTA­ MiTek USA, Inc. Site Information: 6904 Parke East Blvd. Customer Info: SION HOMES CONSTRUG �roject Name: LOT 2 Model: Tampa, FL 33610-4115 Lot/Block: SZ`d`i;is,ion: ACQUA VISTA Address: UNKNOWN City: ST LUCIE COUNTY State: FL Name Address and License # of Structural Engin er of Record, If there is one, for the building. Name: License #: Address: City: State: General Truss Engineering Criteria & Design Loading Conditions): Design Code: FBC2017/TP12014 Wind Code: ASCE 7-10 Roof Load: 45.0 psf This package includes 76 individual, Truss Design With my seal affixed to this sheet, I hereby certify tl conforms to 61 G 15-31.003, section 5 of the Florida (individual Truss Design Drawings Show Special a Program: MiTek 20/20 8.1 Speed: 170 mph Load: 65.0 psf wings and 0 Additional Drawings. I am the Truss Design Engineer and this index sheet ard of Professional Engineers Rules. I No. I Seal# i Truss Namee[�� No. � Seal#� � Truss Name Date 11 IT155605571A 111/12/18 118 1 T1 5560574 1 FLB 11/1 2/F8 12 IT15560558JAl 111/12/18 119 1 T1 5560575 1 FLC 111/12/18 13 T15560559JA2 111/12/18 120 1 TI 5560576 1 FLD 111/12/18 14 IT1556056OIA3 111/12/18 121 1 T1 5560577 1 FLE 111/12/18 15 1 T1 55605611 A4 111/12/18 122 1 T1 5560578 1 FLF 111/12/18 16 IT15560562IA5 111/12/18 123 1 T1 5560579 1 FLG 111/12/181 17 IT155605631B 111/12/18 124 1 T1 5560580 1 FLH 111/12/18 18 1 T1 5560564 1 B1 111/12/18 125 1 T1 55605811 FLI 111/12/18 19 1 T1 5560565 1 B2 111/12/18 126 1 T1 5560582 1 FLJ 111/12/18 110 1 T1 5560566 1 E13 111/12/18 127 1 T1 5560583 1 FLK 111/12/18 Ill I T1 5560567 1 B4 111/12/18 128 1 T1 55605841 FLL 111/12/18 112 1 T1 5560568 1 E15 111/12/18 129 1 T1 5560585 1 FLM 111/12/181 113 1 T1 5560569 1 E16 111/12/18 130 1 T1 55605861 GEE 111/12/18 114 1 T1 5560570 1 C 111/12/18 131 1 T1 55605871 G FZ 111/12/181 115 1 T1 55605711 C1 111/12/18132 1 T1 5560588 1 G RA 111/12/18 116 1 T1 5560572 1 E 111/12/18133 1 T1 55605891 G RB 111/12/18 117 1 T1 5560573 1 FLA 111/12/18 134 1 T1 5560590 1 G RC 111/12/18 The truss drawing(s) referenced above have been prepared by MiTek USA, Inc. under my direct supervision based on the parameters provided by Chambers Truss. Truss Design Engineer's Name: Finn, Walter My license renewal date for the state of Florida is February 28, 2019. IMPORTANT NOTE: The seal on these truss component designs is a certification that the engineer named is licensed in the jurisdiction(s) identified and �that the designs comply with ANSI/TPI 1. These designs are based upon paral�eters shown (6.g., loads, supports, dimensions, shapes and design codes), �Vhich were given to MiTek. Any project specific information included is for MiTek�s customers file reference purpose only, and was not taken into account in the preplaration of these designs. MiTek has not independently verified the he design parameters or the designs for any particular building. Bef r use, t e buildl id W ng ril should verify applicability of design parameters and propEe oraFAse into the overall building design per ANSI/TPl 1, Chapter 2 11 am RECEIVED JAN 2-5 120iq $T. Lucie County, Permitting R P E N No 22839 STATE OF .00. v, till Walter R Finn PE No.22839 MiTek USA, Inc. FIL Cert 6634 6904 Parke East Blvd. Tampa FL 33610 Py Date: November 12,2018 Finn, Walter I of 2 RE: 75575 - ACQUAVISTA Site Information: Customer Info: SION HOMES CONSTRUCTION Project Name: LOT 2 Model: Lot/Block: Subdivision: ACQUA VISTA Address: UNKNOWN City: ST LUCIE COUNTY State: FL INo. I Seal# I Truss Name I Date 135 1 T1 55605911 GRD 111/12/1 136 1 T1 5560592 1 G RK 111/12/181 137 1 T1 5560593 1 G RL 111/12/18 138 1 T1 5560594 1 GRP 111/12/18 139 1 T1 5560595 1 G RR 111/12/18 140 IT15560596IJ1 111/12/18 141 IT15560597IJ3 111/12/18 142 IT15560598IJ3A 111/12/18 143 IT15560599IJ5 111/12/181 144 IT15560600IJ7 111/12/181 145 IT155606011JA 111/12/181 146 IT15560602IJB 111/12/181 147 IT155606031JUl 111/12/181 148 IT155606041JU3 111/12/181 149 1 T1 5560605 1 K 111/12/181 150 1 T1 5560606 1 K1 111/12/181 151 1 T1 5560607 1 K2 111/12/181 152 1 T1 5560608 1 KJ3 111/12/181 153 IT155606091KJ5 111/12/181 154 IT155606101KJ7 111/12/181 155 1 T1 55606111 KJA 111/12/18 156 1 T1 5560612 1 KJ B 111/12/18 157 1 T1 55606131 KJC 111/12/18 158 IT155606141L 111/12/18 159 1 T1 5560615 1 Ll 111/12/18 160 IT15560616IL2 111/12/18 161 IT15560617IL3 111/12/181 162 1 T1 5560618 1 M 111/12/18 163 1 T1 5560619 1 M1 111/12/181 164 1 T1 5560620 1 M2 111/12/181 165 1 T1 5560621 1 MV2 111/12/181 166 1 T1 5560622 1 MV4 111/12/181 167 1 T1 5560623 1 MV6 111/12/181 168 1 T1 5560624 1 N 111/12/181 169 1 T1 5560625 10 111/12/18 170 IT155606261P 111/12/181 171 1 T1 5560627 1 R 111/12/181 172 1 T1 5560628 1 SFBB01 111/12/181 173 1 T1 5560629 1 V4 111/12/181 174 1 T1 5560630 1 V8 111/12/181 175 1 T1 55606311 V1 2 111/12/181 176 1 T1 5560632 1 V1 6 111/12/181 2 6f 2 1 Job Truss Truss Type W 3. Qty Ply ACQUAVISTA T15560557 75575 A Common 2 1 Job Reference (optional), L,naMDers I russ, Inc., r-ori riercL, M 12-3-15 6-0-11 �6-5-3 i 5x6 5.00 [12 0. IOU b Mid[ I I — 10 IVIi I — I 1 11— IVIUi I I — 14 V-0— — I U ­9� I vRD)CrOZhc4Bay—yKyKq-kl2OPXf4o3-ZkcoRQ]QylzU9zYk2Yw1 F6dtWOcyJz85 �1 -12 28-8-13 35-0-0 6-0-11 6-3-3 Scale = 1:59.0 5x6 WEI -�- 3X4 3X4 _- 5 7 5x6 WEI 23 24 a 25 3X4 7 5X6 WEI 24 a 25 3X4 1\ 3x4 22 2 13 28 1229 11 3x4 46 4X6 3x4 3x8 3X8 - Plate LOADING (psf) TCLL 20.0 TCDL 15.0 BCLL 0.0 BCDL 10.0 B-8-1 SPACING- 2-0-0 CSI. Plate Grip DOL 1.25 TC 0.66 Lumber DOL 1.25 BC 0.61 Rep Stress Incr YES WB 0.93 Code FBC2017ITP12014 Matrix -MS 3X8 = 35-0-0 DEFL. in (loc) I/defl Ud PLATES GRIP Vert(LL) -0.19 13-15 >999 360 MT20 244/190 Vert(CT) -0.43 13-15 >983 , 240 Horz(CT) 0.12 10 n/a n/a Wind(LL) 0.36 13-15 >999 240 Weight: 173 lb FT = 20% LUMEl BRACING - TOP CHORD 2X4 SP M 30 TOPCHORD Structural wood sheathing directly applied or 3-7-10 oc purlins. BOT CHORD 2x4 SP M 30 BOTCHORD Rigid ceiling directly applied or 4-0-5 oc bracing. WEBS 2x4 SP No.3 WEBS I Row at midpt 6-13 OTHERS 2x4 SP No.3 REACTIONS. (lb/size) 2=1682/0-'8-0, 10=1573/Mechanical Max Harz 2=416(LC 11) Max Uplift 2=-1545(LC 12),10-1344(LC 12) FORCES. (lb) -Max. Comp./Max. Ten. -All forces 250 (lb).or less except when shown. TO CHORD 2-3=-3528/3196, 3-5=-3262/2959, 5-6=-229212239, 6-7=-2292/2273, 7-9=-3262/3101, 9-1 0=-352813378 1 BOTCHORD 2-15=-2797/3319,13-15=-2150/2555,11-13=-2120/2454, 110-11=-290213190 WEBS 6-13=-1278/1404,7-13=-912/1005,7-11=-604[720,9-11=-528/7501 5-13=-905/998, 5-15=-500[7031 3-1 5=-528/662 NOTES- 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-10; Vuft=1 70mph (3-second gust) Vasd=132mph' TCDL=4.2psf; BCDL=3.Opsf; h=33ft; B=53ft; L=65ft; eave=7ft; Cat. 11; Exp D; Encl., GCpi=0.18; MWFRS (directional) and C-C Exterior(2) 11-6-0 to 4i 1 11-13, Interior(l) 4-11-13 to 17-6-0, Exterior(2) 17-6-0 to 23-11-13 zone;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent,with any other live loads. 4) * This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members, with BCDIL = 1 O.Opsf. 5) Refer to girder(s) for truss to truss connections. 6) Provide mechanical connection (by others) of truss to bearing plate capable of wit i hstanding 100 lb uplift at joint(s) except at=lb) 2=1545,10=1344. to- Ii 0 Walter P. Finn PE No.22839 MiTek USA, InIc. Fl. Ced 663.4 6904 Parke East Blvd. Tampa Fl. 33610 Date: November 12,2018 WARNING. Verify design parameters and READ NOTES ON THISAND INCLUDED MITEKREFERANCE PAGE 1101-7473 rev. 1010*015 BEFORE USE. Design valid for use onlywIth MITek@ connectors. This design Is based only upon parameters shown, and Is for an individual building component not a truss system. Before use, the building designer must verify the applicability of design parom6ters and properly Incorporate this design Into the overall building design. Bracing Indicated Is to prevent buckling of Individual truss web and/or chord members only. Additional temporary and permanent bracing MOW Is always required for stability and to prevent collapse with possible personal Injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, seeANSVMII Quality Criteria. DSB-89 and BCSI Bullding Component 6904 Parke East Blvd. Sailoty [nformationavallable from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314. Tampa, FL 33610 Job Tru s Truss Type Qty Ply ACQUAVIII TA T15560558 75575 At Hip 1 1 Job Reference (optional) uhambers Truss, inc., Fort Pierce, FL 6.130 s Mar 11 20 i 8 Ivii i uK bidubineN, ifliu. Mufli NOV i4 U9.bo.33 4M rage I ID:aNkrWfLwRDXTOZhc4Bay—yKyKq-CycOctfiZM6QMmNcL_TxBrA1 Kuy4JHNPPLHG3Y2yJz84 11-9-2 17-0-0 2- 1 5 28-10-13 5-0�1 T 110 6-1 5-7-14 5-2-14 _1 .5.-2 4 5-7-1.4 _T. Scale 1:61.4 5x6 5.00F1_2 5x6 6 7 5x6 WB�� 8 5X6 WBZ�- 5 4 9 25 26 27 10 3 24 2 117 6 17 16 15 14 13 12 4x6 4x6 3x8 3X8 8-9-14 17-0-0 26-2-2 35-0-0 8-9-14 8-2-2 ?L001 B-2-2 B-9-14 Plate Offsets (X,Y)-- r2:0-8-0,0-0-10j,[4:0-3-0,Edc iel,[6:0-3-0,0-2-41,[7:0-3-0,0-2-41,[9:0-3-0,Edq _e ]'[11:0-8-0,0-0-101 LOADING (ps� SPACING- 2-0-0 CS1. DEFL. in (loc) I/defl Ud PLATES GRIP TCLL 20.0 Plate Grip DOL 1.25 TC 0.65 Vert(LL) -0.15 15 >999 360 MT20 244/190 TCDL 15.0 Lumber DOL 1.25 BC 0.61 Vert(CT) -0.38 15-17 >999 240 BCLL 0.0 Rep Stress Incr YES WB 0.92 Horz(CT) 0.13 11 n/a n1a BCDL 10.0 Code FBC2017fTP12014 Matrix -MS Wind(LL) 0.34 15 >999 240 Weight: 182 lb FT = 20% LUMBER- BRACING- TOPCHORD 2X4 SP M 30 TOP CHORE BOTCHORD 2X4 SP M 30 BOT CHORE WEBS 2x4 SP No.3 OTHERS 2x4 SP No.3 REACTIONS. (lb/size) 2=1682/0-8-0,11=1573/Mechanical Max Horz 2=405(LC 11) Max Uplift 2=-1545(LC 12), 1 1=-1 344(LC 12) FORCES. (lb) -Max. Comp./Max. Ten. -All forces 250 (lb) or less except when shown. TOPCHORD 2-3=-3522/3397, 3-5=-3245/3156, 5-6=-2314/2375, 6�-7=-2158/231 7-8=-2314/2404, 8-1 0=-3245/3185, 10-11 =-3522/3487 BOTCHORD 2-17=-3056/3186, 15-17=-2399/2511, 14-15=-1 595/1949, 12- 1 4=-2328/2517, 11-12=-3056/3186 WEBS 3-17=-508/631, 5-17=-428/616, 5-1 5=-898/1106, 6-15-1365/6811 )1-14---674/68 1, 8-14=-905/1115, 8-12=-529/632,10-12=-511/733 Structural wood sheathing directly applied or 3-7-8 oc purlins. Rigid ceiling directly applied or 3-11-9 oc bracing. NOTES- 1 ) Unbalanced roof live loads have been considered for this design. 2) Wind: ASIDE 7-10; Vult=170mph (3-second gust) Vasd=132mph; TCLJL=4.ZPST; BCDL=3.Opsf; h=33ft; B=53ft; L=65ft; eave=7ft; Cat. 11; Exp D; Encl., GCpi=0.18; MWFRS (directional) and C-C Exteflor(2) -1-6-0 to 4111-13 Interion(i) 4-11-13 to 17-0-0, Exterior(2) 17-0-0 to 18-0-0, Interior(l) 27-2-1 to 35-0-0 zone;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) Provide adequate drainage to prevent water ponding. 4) All plates are 3x4 MT20 unless otherwise indicated. 5) This truss has been designed for a 10.0 psf bottom chord live load nonconcurreni with any other live loads. 6) * This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 7) Refer to girder(s) for truss to truss connections. 8) Provide mechanical connection (by others) of truss to bearing plate capable of wiLtanding 100 lb uplift at joint(s) except at=lb) 2=1545,11=1344. Walter P. Finn PE No.22839 MiTek USA, Inc. fl. Cori 6634 6904 Parke East Blvd. Tampa FIL 33810 Date: November 12,2018 . A WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MfrEK.E1ERANCE PAGE MIP7473 rev. 1010312015 BEFORE USE. Design valid for use only.with MITek@ connectors, This design Is based only upon parameters s , hown, and Is for an Individual bullcing component, nc a truss system. Before use, the building designer must "all verity the applicability of design parcm6ters and properly Incorporate this design Into the ove" building design. Bracing Indicated Is to prevent buckling of Individual truss web and/or chord members only. Additional temporary and permanent bracing MiTek' Is always required for stability and to prevent collapse with possible personal Injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, seeANSI/Tpll Quo' Criteria, DSB-69 and BCSI Bullding Component 6904 Parke East Blvd. safety Infarmationavallable from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandric,IVA 22114, Tampa, FL 33610 Job s Type *F i Qty Ply ACQUAVISTA T15560559 75575 A2 Hip Job*Reference (optional) Chambers I russ, Inc., hort Fierce, I-L 1-6-0 ' 7-8-5 5xl 2 MT1 BHS = t5. iou s iviar i i /uio ivii i uK inuiubuiets, ii iv. iviuii iiuv 14 uv-oo.o� 4u I o rayu . ID:aNkrWfLwRDXTOZhc4Bay—yKyKq-g8AmqDgKKgEHzwyqYASQNOaS2LQDOynyzxMd4VyJz83 T'_0_0 27-3-11 35-0-0 5.6--_0 7-3-11 7-8-5 Scale = 1:62.2 5x8 MT1 BHS 5.00 F12 4 22 5 5x12 IAT18HS-�-- 5x12 MT18HS-- 1; 24 21 a 20 (b 2 7 .10 __— - I ;; 13 12 11 10 9 3X4 11 4x6 3X4 3x8 4x6 3X4 11 3x8 3x6 15-0-0 77-:1 00 27-3-11 L_ 35-0-0 i 7-3-11 1 N-T 7-3-11 7-8-5 Plate Offsets (X,Y)-- [2:0-0-6,Edqel,[3:0-6-0,0-3-01,[4:0-8-0,0-1-121,[5:0-4-8,0-2-01,[6:0-6-0,0-3-0l,[7:0-4-2,0-1-81 LOADING (psf) SPACING- 2-0-0 CSI. DEFL. in (loc) Vdefl Ud PLATES GRIP TCLL 20.0 Plate Grip DOL 1.25 TC 0.88 Vert(LL) -0.15 10-11 >999 360 MT20 244/190 TCDL 15.0 Lumber DOL 1.25 BC 0.63 Vert(CT) -0.36 11-13 >999 240 MT18HS 244/190 BCLL 0.0 Rep Stress Incr YES WB 0.40 Horz(CT) 0.13 7 n1a n1a BCDL 10.0 Code FBC2017/TP12014 Matrix -MS Wind(LL) 0.34 10-11 >999 240 Weight: 171 lb FT = 20% LIUMBER- BRACING - TOP CHORD 2x4 SP M 30 TOPCHORD Structural wood sheathing directly applied or 3-5-15, oc purlins. BOTCHORD 2x4 SP M 30 BOTCHORD Rigid ceiling directly applied or 3-7-5 oc bracing. WEBS 2x4 SP No.3 WEBS 1 Row at micipt �1-1 1, 6-10 REACTIONS. (lb/size) 2=1682/0-8-0,7=1573/Mechanical Max Horz 2=361 (LC 11) Max Uplift 2=-1 545(LC 12), 7=-1 344(LC 12) FORCES. (lb) -Max. Comp./Max. Ten. -All forces 250 (lb) or less except when shown. TOPCHORD 2-3=-3414/3512, 3-4=-2493/2664, 4-5=-2325/2590, 5-6=-2493/2612, 6-7=-3414/3495 BOTCHORD 2-13=-3141/3095, 11-13=-3140/3096, 10-11 =-1 984/2168, B-1 0=-3086/3070, 7-8=-3087/3069 WEBS 3-13=0/331, 3-11 =- 1116/1272, 4-11 =-474/553, 4-1 0=-271/273, 5-1 0=-530/554, 6-1 0=-1 124/1295, 6-8=-24/334 NOTES- 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-10; Vult=170mph (37second gust) Vasd=132mph; TCUL=4.zpst; BCDL=3.Opsf; h=33ft; B=53ft; L=65ft; eave=7ft; Cat. 11; Exp D; Encl., GCpi=0.18; MWFRS (directional) and C-C Exterior(2) -1-6-OW4111-13 lnte6or(1)4-11-13tol5-0-0,Extedor(2) 15-0-0 to 20-0-0, Interior(l) 29-2-1 to 35-0-0 zone;C-,C for members and forces il MWF�S for actions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) Provide adequate drainage to prevent water poncling. 4) All plates are MT20 plates unless otherwise indicated. 5) This truss has been designed for a 10.0 psf bottom chord live load nonconcurren� with any other live loads. 6) * This truss has been designed for a,live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 7) Refer to girder(s) fortruss to truss connections. 8) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) except Ot=lb) 2=1545,7=1344. C Walter P. Finn.PE No.22839 MiTek USA, Inc, FL Cart 6634 6904 Parke East Blvd. Tampa FL 33610 Date: November 12,2018 WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERANCE PAGE MIP7473 rev. I W=0 IS BEFORE USE. Design valid for use only with Mj7ek@) connectors. This design Is based only upon parameters ihown, and is for an Individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly Incorporate this design Into the overall building design. Bracing Indicated is to prevent buckling of Individual truss web and/or chor8 members only. Additional temporary and permanent bracing MiTek' Is always required for stability and to prevent collapse with possible personal Injury and property fabrication, storage, delivery, erection and bracing of trusses and truss systems, seeANSIM111 I damage. For general guidance regarding the - Quality Criteria, DSB-89 and BCSI Bunding Component, 6904 Parke East Blvd. Satiety Informationavoilable from Truss Plate Institute, 218 N. Leg Street, Suite 312, Alexandria,l VA 22314. Tampa, FL 33610. Job Truss Truss Type Qty Ply ACQUAVII TA T15560560 75575 A3 Hip Job Reference (optional) Uhambers I russ, Inc., F-ort I-lierce, t-L i I - 7-8-6 I-M 7-8-6 2 3x8 = 5x6 = 4 23 5.00 P-2 6x8 3 22 21 !�� 14 3x4 11 13-0-0 13 12 4x6 = 3X8 miou s mar 1 1 i�U 10 IVII I eK inuusures, mu. rviun ivuv je uv;oo;0o 4v 1 o rdyu I ID:aNkrWfLwRDXTOZhc4Bay—yKyKq-8Ki9lYhy5_M8b4WO6tzfwb6dElkliLliob5AdxyJz82 L2-00 27-3-10 35-0-0 6.� i i 4 5-3-10 7-8-6 3x4 = . 5x6 5 24 6 6x8 7 25 27 28 11 10 9 3x8 3X4 11 4x6 1( 0 Scale = 1:61.1 � 7 CP 26 8 3x8 Plate Offsets (X,Y)-- [2:0-8-0,0-0-101,[4:0-3-0,0-2-41,[6:0-3-0,0-2-41,[8:0-8-0,0-0-101 LOADING (psf) SPACING- 2-0-0 CSI. DEFL. in (loc) Ildefl Ud PLATES GRIP TCLL 20.0 Plate Grip DOL 1.25 TC 0.85 Vert(LL) -0.21 11-12 >999 360 MT20 244/190 TCDL 15.0 Lumber DOL 1.25 BC 0.66 Vert(CT) -0.51 11-12 >831 240 BCLL 0.b Rep Stress Incr YES WB 0.66 Horz(CT) 0.13 8 n/a n/a BCDL 10.0 Code FBC2017[TP[2014 Matrix -MS Wind(LL) 0.36 11-12 >999 240 Weight: 172 lb FT = 20% LIUMBER- BRACING- TOPCHORD 2x4 SP M 30 TOPCHORD Structural wood sheathing directly applied or 3-3-7 oc purlins. BOTCHORD 2x4 SP M 30 BOTCHORD Rigid ceiling directly applied or 3-5-10 oc bracing. WEBS 2x4 SP No.3 REACTIONS. (lb/size) 8=1573/Mechanical,2=1682/0-8-0 Max Harz 2=317(LC 11) Max Uplift 8=-1344(LC 12), 2=-1545(LC 12) FORCES. (lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shivin. TOPCHORD 2-3=-3350/3622, 3-4=-2673/2988, 4-5=-2485/2877, 51_6=-2485/284b, 6-7=-2673/2953, 7-8=-3371/3605 BOTCHORD 2-14=-3218/3116,12-14=-3218/3116,11-12=-245912522,9-11=-3 65/3035, B-9=-3165/3035 WEBS 3-14=-1 9/258, 3-12=-877/1083, 4-12=-73Of741, 5-12=-351/447, 5- 1 =-348/428, 6-11 =-773f741, 7-11 =-877/1106, 7-9=-54/262 NOTES- 1 ) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-10; Vult=170mph (3-second gust) Vasd=132mph; TCDL=4.2psf; BCDL=3.Opsf; h=33ft; B=53ft; L=65ft; eave=7ft; Cat. 11; Exp D; Encl., GCpi=0.18; MWFRS (directional) and C-C Exterior(2) -1-6-0 to 4111-13 Interior(l) 4-11-13 to 13-0-0, Exterior(2) 13-0-0 to 22-0-0, Interior(l) 31-2-1 to 35-0-0 zone;C-C for members and forces &I MWF�S for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) Provide adequate drainage to prevent water ponding. 4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 5) * This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members, with BCDL = I O.Opsf. 6) Refer to girder(s) for truss to truss connections. 7) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) except at=lb) 8=1344,2=1545. Walter P. Finn PE No.22839 MiTek USA, Inc. FL Carl 6634 6904 Parke East Blvd. Tampa FL 33610 Datc No vember 12,2018 WARNING- Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERA'NCE PAGE MX7473 rev'. 1610342015 BEFORE USE. Design valid for use only with MITek@ connectors. This design Is based only upon parameters shown, and Is for an Individual building component not a truss system. Before use, the building designer must verity the applicability of design parom6ters, and properly Incorporate this design Into the overall building design. Bracing Indicated is to prevent buckling of Individual truss web and/or chord members only. Additional temporary and permanent bracing MiTek' Is always required for stability and to prevent collapse with possible personal Injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, seeANSIMIJ QUallty Clffgrkx,.DSB.89 and IICSI Bulli Component Safety Informationavallable from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, IVA 22314. 6904 Parke East Blvd. Tampa, Fl- 33610 Job Tru a Truss Type Qty Ply ACQUAVISTA T15560561 75575 A4 Hip Job Reference (optional) L;hambers Truss, Inc., Fort Pierce, FL 8.130 a Mar 11 2018 MiTek Indusines, inc. Mon Nov 12 09;38.36 4018 rdue i ID:aNkrWfLwRDXTOZhc4Bay—yKyKq-cXHXEuiasHU—DE5CfbVuTpfou949Umgr1 Fd9NyJz8l 6-01 7-8-4 0 17-6-0 400 g7 ' 2 35-0-0 _0 7-8-4 1-6 5.3. 6-6-0 6 3512 7-8-4 Scale 1:61.1 5x8 MT1 8HS 3x4 11 5x8 MT1 8HS 4 24 5 25 26 6 5. 00 F1 _2 5x6 i�-- '.uu'-r2 9x6 1 - 5X6 3 7 27 23 7 ;z 22 8 7 '41 2 14 13 12 11 10 9 3x4 11 3x6 3x8 3X4 3x4 I I 3x8 3x8 3x4 3x6 1 17-6.0 Z7 �8 40-0 L 7 N 2 35-0-0 4 m-- V4 6-6-0 1 6 .0 3 -_12 7-8-4 Plate Offsets (X,Y)-- r2:0-8-0,0-0-101,[4:0-5-12,0-2-8l,r6:0-5-12,0-2-81,[8:0-8-0,0-0-101 LOADING (psf) SPACING- 2-0-0 CS1. DEFL. in (loc) I/deff Ud PLATES GRIP TCLL 20.0 Plate Grip DOL 1.25 TC 0.86 Vert(LL) -0.17 12 >999 360 MT20 244/190 TCDL 15.0 Lumber DOL 1.25 BC 0.66 Vert(CT) -0.40 10-12 >999 240 MT18HS 244/190 BCLL 0.0 Rep Stress Incr YES WB 0.82 Horz(CT) 0.13 8 n/a n/a BCDL 10.0 Code FBC2017frP]2014 Matrix -MS Wind(LL) 0.39 12 >999 240 Weight: 173 lb FT = 20% LUMBER- BRACING - TOP CHORD 2x4 SP M 30 TOPCHORD Structural wood sheathing directly applied or 3-2-2 oc purlins. BOTCHORD 2x4 SP M 30 BOTCHORD Rigid ceiling directly applied or3-5-3 oc bracing. WEBS 2x4 SP No.3 REACTIONS. (lb/size) 8=1573/Mechanical, 2=16B2/0-8-0 Max Horz 2=273(LC 11) Max Uplift 8=-1344(LC 12), 2=-1545(LC 12) FORCES. (lb) -Max. Comp./Max. Ten. -All forces 250 (lb) or less except when shown. TOPCHORD 2-3=-3348/3603, 3-4=-2848/3214, 4-5=-3069/3502, 5-6=-3069/350�, 6-7=-2853/3183, 7-8=-3369/3587 1 BOTCHORD 2-15=-3177/3009,14-15=-3177/3009,12-14=-2521/2o/t5, 10-12=-2451/2584, 9- 1 0=-3124/3031, 8-9=-3124/3031 1 WEBS 3-1 5=-56/256, 3-14=-7221922, 4-14=-573/552, 4-12=-715/695, 5-12=-530/78 1, 6-12=-687/690, 6-1 0=-585/556, 7-1 0=-7291947, 7-9=-80/261 1 NOTES- 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASIDE 7-10; Vult=170mph (3-second gust) Vasd=132mph; TCUL,"-��PsT; CDL=3.Opsf; h=33ft; B=53ft; L=66ft; eave=7ft; Cat. 11; Exp D; Encl., GCpi=0.18; MWFFIS (directional) and C-C Exterion(2) - -6-Oto'�11-13,lnterior(1)4-11-13toll-0-0,Exterior(2) 11 -0-0 to 33-2-1, Interior(l) 33-2-1 to 35-0-0 zone;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) Provide adequate drainage to prevent water poncling. 4) All plates are MT20 plates unless otherwise indicated. 5) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent, with any other live loads. 6) * This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 7) Refer to girder(s) for truss to truss connections. 8) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) except at=lb) 8=1344,2=1545. 1 Walter P. Finn PE No.22839 MiTek USA, Inc. FL Carl 6634 6904 Parke East Blvd. Tampa FL 33610 Date: November 12,"2018 ,&WARNING -Verify design parameters and READ NOTES ON THIS AND INCLUDED M11`EKREFERhNCE PAGE M11-7473 rev. 1010312015 BEFORE USE. Design valid for use only with MiTek@ connectors. This design Is based only upon parameters shown, and Is for an Individual building component, not a truss system. Before use, the building designer must verify the applIcability of design parameters and properly Incorporate this design Into the overall building design. Bracing Indicated Is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing MiTek' Is always required for stability and to prevent collapse with possible personal Injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, seeANSVTPII Quality Critedo, DSB-69 and BCSI Building Component 6904 Parke East Blvd. Safety Infonnotlonovallable from Truss Plate Institute; 218 N. Lee Street, Suite 312. Alexandria, VA 22314. Tampa, FIL 33610 Job ru S Truss Type Qty Ply ACQUAVISTA T15560562 75575 A5 Hip 1 1 Job Reference (optional) L;naMDers I russ, inc., ran rierce, rL 3-3-4 5x8 IvIT1 8HS = 5.00FI-2 4 3x4 23 3 2 16 3X6 3x4 9-0-0 14-8-9 3x4 5 15 14 4x6 3x4 ID:aNkrWfLwRDXTOZhc4Bay—yKyKq-4irvSEiDdbcrqNgPD107?OCOgZRIDCy—FvaHhqyJz8O 26-0-0 ?13 1 35-0-0 5-8-9 5-8-12 5xB NIT1 BHS = 5x8 MT1 8HS = 3x4 11 24 6 25 7 8 13 12 11 M 4x6 3x4 5-8-9 LOADING (pso SPACING- 2-0-0 CSI. DEFL. in (loc) I/defI Ud TCLL 20.0 Plate Grip DOL 1.25 TC 0.66 Vert(LL) -0.22 13-14 >999 360 TCDL 1 6.0 Lumber DOL 1 * 25 BC 0.61 Vert(CT) -0.50 13-14 >839 240 BCLL 0.0 Rep Stress Incr YES Wb 0.89 Horz(CT) 0.14 10 n/a nia BCDL 10.0 Code FBC2017fTP]2014 Matrix -MS Wind(LL) 0.49 13-14 >849 240 LUMBER - TOP CHORD 2X4 SP M 30 BOT CHORD 2X4 SP M 30 WEBS 2x4 SP No.3 REACTIONS. (lb/size) 10=1573/Mechanical,2=1682/0-8-0 Max Horz 2=228(LC 11) Max Uplift 1 0=-1 344(LC 12), 2=-1 545(LC 12) FORCES. (lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shc TOPCHORD '2-3=-3412/3699, 3-4=-3084/3321, 4-5=-3583/3939, 5-7=-3585/39& B-9=-3098/3344, 9-10=-3436/3701 1 BOTCHORD 2-16=-3291/3108, 14-16=-2721/2811, 113-14=-3514/3583, 11 - 1 3=-2 10- 11 =-3257/3135 1 WEBS 3-16=45W700, 4-16=-367/440, 4-14=-1 052/1014, 5-14=-462/615, 8-13=-1 007/1005, B-1 1 =-386/447, 9-11 =-463/720 Scale = 1:61.1 26 3X4 - 9 3x8 35-0-0 —9-0-0 . . I PLATES GRIP MT20 244/190 MT18HS 244/190 Weight: 170 lb FT = 20% BRACING- TOPCHORD Structural wood sheathing directly applied or 3-6-4 oc purlins. BOTCHORD Rigid ceiling directly applied or 3-10-2 oc bracing. 7-8=-3585/3983, W2823, 6/631, NOTES- 1 ) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-10; Vult=170mph (3-second gust) Vasd=132mph; TUDL-4.ZPST; BCDL=3.Opsf; h=33ft; B=53ft; L=65ft; eave=7ft; Cat. 11; Exp D; Encl., GCpi=0.18; MWFRS (directional) and C-C Exterion:2) -1-6-0 to 4111-13, Interion(l) 4-11-13 to 9-0-0, Exterior(2) 9-0-0 to 35-0-0 zone;C-C for members and forces & MWFRS for reactions shown; Lum er DOL=1.60 plate grip DOL=1.60 3) Provide adequate drainage to prevent water poncling. 4) All plates are MT20 plates unless otherwise indicated. 5) This truss has been designed for a 10.0 psf bottom chord live load nonconcurreni with any other live loads. 6) * This truss has been designed for a live load of 20.Opsf on the bottorn chord in a[ I areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 7) Refer to girder(s) for truss to truss connections. 8) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) except at=lb) 10=1344,2=1545. 10 6 Walter P. Finn,PE No.22839 MiTek USA, Inc. FL Cod 6634 6904 Parke East Blvd. Tampa FL 33810 Date: November 12,2018 I WARNING - Verify design parameters and READ NOTES ON THISAND INCLUDED MITEKREFERANCE PAGE M11-7473 rev. 1010312015 BEFORE USE. -- Design valid for use only with MITek@ connectors. This design Is based only upon parameters sl�own, and Is for an Individual building component, not a truss system. Before use, the building designer must verity the applicability of design parameters and properly Incorporate this design Into the overall building design. Bracing Indicated Is to prevent buckling of Individual truss web and/or chord members only. Additional temporary and permanent bracing MiTek' Is always required for stability and to prevent collapse with possible personal Injury and prope" damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, seeANSVrPII Qualfty CrIlleft, DSB-89 and BCSI Building Component 6904 Parke East Blvd. Safety Informationavollable from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, YA 22314. Tampa, FL 33610 Job Tru s Truss Type Qty Ply ACQUAVIII TA . . T15560563 75575 B, Hip I 1 JobReference (optional) unambers I russ, Inc., F-ort rierce, I--I- 2 3X8 = Plate 11-1-4 16-4-0 5x6 5.00 r-12 5x6 6 7 5X6 INS 5 4 25 3 24 17 16 15 14 4X6 = 7-8-1 1 1 2-4-0 u.idu s mar ii zuits mtieK inausines, inc. man tmov 14 uu;omovieuib rage i IDXTOZhc4Bay—yKyKq-YvPHfajrOvkiSXFbnOXMYEkCtznhyfG8UZKqDGyJzB? 22-10 12 29-1-8 3� 0-0 5-2-12 Scale 1:61.4 8 5x6 INS 9 26 27 10 13 12 46 3X8 26-4-1 35-0-0 LOADING (psf) SPACING- 2-0-0 CS1. DEFL. in (loc) I/clefl Ud PLATES GRIP TCLL 20.0 Plate Grip DOL 1.25 TC 0.63 Vert(LL) -0.20 15-17 >999 360 MT20 244/190 TCDL 15.0 Lumber DOL 1.25 BC 0.60 Verl(CT). -0.42 15-17 >992 240 BCLL 0.0 Rep Stress Incr YES WB 0.88 Horz(CT) 0.13 11 n/a n1a BCDL 10.0 Code FBC2017[TP12014 Matdx-MS Wind(LL) 0.34 14 >999 240 Weight: 179 lb FT = 20% LIUMB ER- BRACING- TOPCHORD 2X4 SP M 30 TOPCHORE BOTCHORD 2X4 SP M 30 BOT CHORE WEBS 2x4 SP No.3 OTHERS 2X4 SP No.3 REACTIONS. (lb/size) 2=1682/0-8-0,11=1573/0-8 - -0 Max Harz 2=391 (LC 11) . Max Uplift 2=-1545(LC 12), 11=-1344(LC 12) FORCES. (lb) - Max. Comp./Max. Ten. - All forces 250 (lb or less except when shown. TOPCHORD 2-3=-3520/3469, 3-5=-3244/3226, 5-6=-2366/2470, 6-7=-2207/2397, 7-8=-2366/2495, B-1 0=-3244/3218, 10-11 =-3519/3530 i BOTCHORD 2-17=-3124/3193,15-17=-2520/2581, 14-15=-17135/2016,12-14=-2451/2587, 11-12=-3101/3186 WEBS 3-17=-481/605, 5-17=-372/572, 5-15=-905/1096, 6-1 '5=-604/658, 7114=-617/658, 8-14=-913/1108, 8-12=467/589,10-112=48V710 I Structural wood sheathing directly applied or 3-7-6 oc puffins. Rigid ceiling directly applied or 3-11-8 oc bracing. NOTES- 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-10; Vult=170mph (3-second gust) Vas.d=132mph; TC----.-,-., BCDL=3.Opsf; h=33ft; B=53ft; L=65ft; eave=7ft; Cat. 11; Exp D; Encl., GCpi=0.18; MWFPIS (directional) and C-C Extedor(2) -1-6-0 to 41'11-13, Interior(l) 4-11-13 to 16-4-0, Exterior(2) 16-4-0 to 18-8-0, Interlor(l) 27-10-1 to 35-0-0 zone;C-C. for members and forces & MWFRS for reactions shown; Lumber DOL= I.UU plate grip DOL=1.60 3) Provide adequate drainage to prevent water pioncling. 4) All plates are 3x4 MT20 unless otherwise indicated. 5) This truss has been designed for a 10.0 psf bottom chord live load In .... .... ... .... with any other live loads. 6) * This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 7) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) except at=lb) 2=1545,11=1344. waiter P. rjnn PE No.12839 MiTek USA, Inc. FL NO 663,4 6904 Parke East Blvd. Tampa rL 33610 Date: November 12,2018 WARNING - Verify design parameters and READ NOTES ON THISANDINCLUDED mrrEK REFERANCE PAGE M/1-7473 rev. 1010312015 BEFORE USE. Design valid for use only with MffekO connectors. This design Is based only upon parameters si�own, and is for an Individual building component, not a truss system. Before use, the building designer must verify the applicability of design parcrn�ters and properly Incorporate this design Into the overall building design. Bracing Indicated Is to prevent buckling of Individual truss web and/or chord members only. Additional temporary and permanent bracing MiTek' Is always required for stability and to prevent collapse with possible personal Injury and propeoy damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, seeANSIMIJ Qualtily Critaft. DSB.69 and BCSI BuldIng Component 6904 Parke East Blvd. Safoty InfounatlIonavallable from Truss Plate Institute, 218 N. Lee Street Sulte 312. Nexondria, VA 22314. Tampa, FL 33610 Job Tru S Truss Type OF Qty Ply ACQUAVII TA 1 T15560564 75575 B1 Roof Special 1 . . 1 Job Reference (optional) unaMbers I russ, Inc., i--on Fierce, I-L - "Jull I— '.y. , I D: a NkrWfLwR"D'Xd'T'05ZIhvicEt4rBlalye—uy[cK3ylvKilqI ulK61zflftuwukbTli9luCbs'ZI]4[uhqnLj2b4RHJLM5ph8ZHID30miyJz8- 1-11-6-01 7-8-5 15-4-P -4 ?-0-8-0 17-3-1122 35-0-0 .6.0 �. .11 IV -8-4 7-8-5 7 O.g 4.4.0 67 7 Scale = 1:63.3 5xl 2 NIT1 8HS 5.00F1_2 6xl 0 5X8 25 7 5x12 MT18HS 5X6 24 34 d 7 26 d c� 23 ch 2 T� BE 16 15 14 13 12 .11 10 3x4 11 4x6 3 4 3x8 4x6 3x4 11 3xB 3x6 3x4 i 7-8-5 1 5�.4; 110 27-3-12 35-0-0 7-8-5 11-0-0 6-7-12 7-8-4 Plate Offsets (X,Y)-- (2:0-0-6, Edge], [4:0-4-12,0-3-01, [4:0-0-0,0-1-121, [6:0-5-4, Edge], [7:0-5-0,0-2-41, [9:0-!1-_20- 1 -81 LOADING (psf) SPACING- 2-0-0 CS1. DEFL. in (loc) I/defI Ud PLATES GRIP TCLL 20.0 Plate Grip DOL 1.25 TC 0.84 Vert(LIL) -0.23 12-13 >999 360 MT20 244/190 TCDL 15.0 Lumber DOL 1.25 BC 0.73 Vert(CT) -0.51 12-13 >819 240 MT18HS 244/190 BCLL 0.0 Rep Stress Incr YES WB 0.75 Horz(CT) 0.13 9 n1a n/a BCDL 10.0 Code FBC2017[TP]2014 Matrix -MS Wind(LL) 0.64 12-13 >777 240 Weight: 178 lb FT = 20% LUMBER- BRACING- TOPCHORD 2x4 SP M 30 TOPCHORD Structural wood sheathing directly applied or 3-5-2 oc purlins. BOTCHORD 2x4 SP M 30 BOTCHORD Rigid ceiling directly applied or 3-7-7 oc bracing. WEBS 2x4 SP No.3 WEBS 1 Row at midpt 3-14,8-12 REACTIONS. (lb/size) 9=1573/0-8-0,2=1682/0-8-0 Max Harz 2=368(LC 11) Max Uplift 9=-1 344(LC 12), 2=-1 645(LC 12) FORCES. (lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when TOP CHORD 2-3=-3399/3274, 3-5=-2539/2591, 5-6=-2348/2506, 6-7=-2408/254 , 7-8=-2584/2644, B-9=-3398/3355 BOTCHORD 2-16=-2883/3075,14-16=-2883/3075,13-14=-1914/2196,12-13=-1900/2182, 10-1 2=-2891/3049, 9-1 0=-2891/3049 WEBS 3-16=0/298, 3-14=-1061/1052, 5-14=-963/1074, 6-13=-667f7031 6_l12=_275/357, 7-12=-496/552, 8-12=-1017/1087,8-10=-20/308 NOTES- 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-10; Vult=170mph (3-second gust) Vasd=132mph; TCDL=4.2psf; E CDL=3.Op f; h=33 ; B=53 ; L=65 t; eav =7 ; at. 11; Exp D; Encl., GCpi=0.18; MWFRS (directional) and C-C Exterior(2) -1-6-0 to 4-11-13, Intedor(l) 4-11-13 to 15-4-0, Exterior(2) 15-4-0 to 27-3-12, Interior(l) 27-3-12 to 35-0-0 zone;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) Provide adequate drainage to prevent water poncling. 4) All plates are MT20 plates unless otherwise indicated. 5) This truss has been designed for a 10.0 psf bottom chord live load nonconcurreni. with any other live loads. 6) * This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 7) Provide mechanical conne6tion (by others) of truss to bearing plate Capable of withstanding 100 lb uplift at joint(s) except at=lb) 9=1344,2=1545. Walter P. Finn.PE No.22839 MiTek USA, Inc. Fl. Cart 6W 6904 Parke East Blvd. Tampa FL 33810 Iyate: November 12,2018 ,&WARNING -Vertry design parameters and RE4D NOTES ON THIS AND INCLUDED MITEKREFER�NCE PAGE MX7473 rev. 10103)2015 BEFORE USE. Design valid for use only with MiTek@ connectors. This design is based only upon parameters shown, and is for an Individual building component, not a truss system. Before use, the building designer must verify the applicability of design parom6ters building design. Bracing Indicated Is to buckling of Individual truss web and/or chord, and properly Incorporate this design Into the overall members only. Additional temporary and permanent bracing MiTek' prevent Is always required for stability and to prevent collapse with possible personal Injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, seeANSVTPII Quality Ciftedo, DSB-89 and Best SuDdIng Component 6904 Parke East Blvd. Safety Informciflonavollable from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria VA 22314. Tampa, FL 33610 Job S Type Qty Ply ACQUAVISTA T15560565 75575 B2 Roof Special Job Reference (optional) unamDers I russ, Inc., t-on Fierce, F-L 7-8-5 7-8-5 t5. iou s rviar it euto ivii i wK uiuubujub, mu. muit imuv 14 UU;00;4U 4u 10 rayu 1 ID:aNkrWfLwRDXTOZhc4Bay—yKyKq-VIX24G]5wW—QhrPzuRZqdfqUymSgQbLRytpxH8yJz7z ' 1 . I L7_ N 2. 35-0-0 4-Ti. ".�_l 2 7-8-4 Scale = 1:63.3 5kB 5.00F12 5x12 5x6 6 5x12 MT18HS 5� 3X4 24 34 8 25 26 d '7 23 >3,x,4 2 9 e 16 15 14 13 12 11 10 3x4 11 46 4<8 3x4 11 46 3x8 3x4 11 3XB 3x6 7-8-5 15 8-.1-00 21-.1 �7 3- 2 35-0-0 7-8-5 T�4;0 3 4 4 112 1 7-8-4 P late Offsets (X,Y)-- f2:0-0-6, Edq el, [4:0-5-0,0-3-41, [4:0-0-0,0-1 -121, [7:0-3-0,0-2-41, [9:0-4-2, 0-1 -81 LOADING (psf) SPACING- 2-0-0 CS1. DEFL. in (loc) I/clef] Ud PLATES GRIP TCLL 20.0 Plate Grip DOL 1.25 TC 0.85 Vert(LL) -0.17 13 >999 360 MT20 244/190 TCDL 15.0 Lumber DOL 1.25 BC 0.66 Vert(CT) -0.39 14-16 >999 240 MT18HS 244/190 BCLL 0.0 Rep Stress Incir YES WB 0.72 Horz(CT) 0.13 9 n/a n1a BCDL 10.0 Code FBC2017fTP12014 Matrix -MS Wind(LL) 0.38 13 >999 240 Weight: 181 lb FT = 20% LUMBER- BRACING - TOP CHORD 2x4 SP M 30 TOPCHORD Structural wood sheathing directly applied or 3-2-8 oc purlins. BOTCHORD 2x4 SP M 30 BOTCHORD Rigid ceiling directly applied or 3-6-7 oc bracing. WEBS 2x4 SP No.3 WEBS 1 Row at midpt 3-14,5-14 REACTIONS., (lb/size) 9=1573/0-8-0,2=1682/0-8-0 Max Harz 2=368(LC 11) . Max Uplift 9=-1344(LC 12), 2=-1545(LC 12) FORCES. (lb) -Max. Comp./Max. Ten. -All forces 250 (lb) or less except when shown. TOPCHORD 2-3=-3433/3287,3-5=-2492/2518,5�6=-2473/2609,6-7=-2581/270 17-8=-277 851, 8-9=-3388/3369 BOTCHORD 2-16=-2897/3084,14-16=-2897/3084,13-14=-2389/2648,11-13=-2� 88/2649, 10-11=-2907/3035,9-10=-2907/3035 WEBS 3-16=01331,3-14=-1133/1152,5-14=-1427/1481, 6-11=-414/379,7[11=-758f797, 8-11=-842/934,8-10=-60/287,6-14=-1060/1215 NOTES- 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-10; Vult=170mph (3-second gust) Vasd=132mph; TCDL=4.2psf; BCDL=3.Opsf; h=33ft; B=53ft; L=65ft; eave=7ft; Cat. 11; Exp D; Encl., GCpi=0.18; MWFRS (directional) and C-C Exterior(2) -1-6-0 to 4- 1-13, Interion(l) 4-11-13 to 15-.4-0, Exterior(2) 15-4-0 to 29-1-13, Interior(l) 29-1-13 to 35-0-0 zone;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.6b 3) Provide adequate drainage to prevent water ponding. 4) All plates are, MT20 plates unless otherwise indicated. 5) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 6) * This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. I . . 7) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) except at=lb) 9=1344,2=1545. 1 Walter P. Finn PE No.22839 Il USA, Inc. I'L tort 66 , 34 6904 Parke East Blvd. Tampa FL 33610 Data: November 12,2018 ,& WARNING - VerW design parameters and READ NOTES ON THISAND INCLUDED MITEKREFERA NCE PAGE 11,1114473 rev. 1WO312015 BEFORE USE. Design valid for use only with IVlITek@ connectors, This design Is based only upon parameters sHown, and Is for an Individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly Incorporate this design Into the overall building design. Bracing Indicated Is to prevent buckling of Individual truss web and/or chord,members only. Additional temporary and permanent bracing MiTek' Is always required for stability and to prevent collapse with possible personal Injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, seeANSIMIJ Quality CrItarlo, DSB-89 and BCSI Building Component 6904 Parke East Blvd. SafetV [nformationavoilable from Truss Plate Institute, 218 N. Lee Street, Suite 312, AJexandria, VA 22314. Tampa, FL 33610 Job Truss Truss Type Qty I Ply ACQUAVISTA T15560566 75575 B3 Roof Special Job Reference (optional) L;namDers I russ, inc., ran rierce, t-L — --" —.. 1.V. . I I D: aNkrWfI-wRDX"T0uZ`h c1v41`B[ aly-14y'KI yK`q" �­U"51D I cmj gq6 HJ?—AS 8439sMf—Aoy9 6vaAW YU pbyJz7y 1-6-0 5x8 MT1 8HS = Scale = 1:65.0 5-0o F1-2 5x12 5x6 5x12 MT18HS -- 5 3X4 24 3 7 P7 23 25 26 2 8 9 7 b9l 16 15 14 13 12 11 10 3X4 11 4x6 3 x10 3X4 4x6 3X8 3X4 11 3x6 3x6 15-8-0 7w8n5 15-" 1A-4,Q 4-0 48-0 �7 35-0-0 1 1 7-8-5 7-3-11 0�4 01 0.4-0 4 7-8-5 Plate Offsets (X,Y)-- [3:0-6-0,0-3-01, [6:0-3-0,0-2-41, [8:0-0-6,Edgel LOADING (psf) SPACING- 2-0-0 CS]. DEFL. in (loc) Well Ud PLATES GRIP TCLL 20.0 Plate Grip DOL 1.25 TC 0.83 Vert(LL) -0.18 13-14 >999 360 MT20 244/190 TCDL 16.0 Lumber DOL 1.25 BC 0.62 Vert(CT) -0.40 13-14 >999 240 MT18HS 244/190 BCLL 0.0 Rep Stress Incr YES WB 0.51 Horz(CT) 0.14 8 n/a n/a BCDL 10.0 Code FBC2017/TP12014 Matrix -MS Wind(LL) 0.40 13-14 >999 240 Weight: 178 lb FT = 20% LUMBER- BRACING - TOP CHORD 2x4 SP M 30 TOPCHORD , Structural wood sheathing directly applied or 3-2-12 oc purlins. BOTCHORD 2x4 SP M 30 BOTCHORD Rigid ceiling directly applied or 3-10-3 oc bracing. WEBS 2x4 SP No.3 WEBS 1 Row at midpt 3-14, 5-14, 4-14 REACTIONS. (lb/size) 2=1686/o-8-0, B= 1680/0-8-0 Max Harz 2=369(LC 11) Max Uplift 2=-1540(LC 12), 8=-1540(LC 12) FORCES. (lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOPCHORD 2-3=-3420/3212, 3-4=-2510/2543, 4-5=-2492/2538, 5-6=-2770/2911, 6-7=-3000/3113, 7-8=-3380/3381 1 BOTCHORD 2-16=-2707/3060,14-16=-2709/3045,13-14=-2804/' 1082,11-13=-2803/3085, 10-11 =-2908/303618-1 0=-2908/3036 1 WEBS 3-1 6=-1/333, 3-14=-1 077/1109, 5-14=-1 285/1471, 5- 1 1=430tiono, 6- =-1 02211028, 7-11 =-718/842, 7-1 0=-43/273, 4-14=-1 337/1414 1 NOTES- 1 ) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE7-10; Vult=170mph (3-second gust) Vasd=132mph; TCDL=4.2psf; CDL=3.Opsf; h=33ft; B=53ft; L=65ft; eave=7ft; Cat. 11; Exp D; Encl., GCpi=0.18; MWFRS'(directional) and C-C Exterior(2) -i-6-011o4-hl -13 ' Interior(l) 4-11-13 to 15-4-0, Exterior(2) 15-4-0 to 31-1-13, Interior(l) 31-1-13 to 36-6-0 zone;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=11.60 I 3) Provide adequate drainage to prevent water ponding. 4) All plates are MT20 plates unless otherwise indicated. 5) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent1with any other live loads. 6) * This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 1 7) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) except at=lb) 2=1540,8=1540. Walter P. Finn.PE No.22839 MiTek USA, Inc. FL Cart 6634 6904 Parke East Blvd. Tampa FL 33610 Date; November 12,2018 WARNING - Vartlydesign parameters and RE4D NOTES ON THISAND INCLUDED MITEK REFERANCE I PAGE 11111-7473 rev. 10103)2015 BEFORE USE. -- Design valid for use only with IVllTek8 connectors, This design Is based only upon parameters shown, and Is for an Individual building component not W1, atruss system. Before use, the building designer must verity the applicability of design parameters building design. Bracing Indicated is to prevent buckling of Individual truss web and/or chordImembers and properly Incorporate this design Into the overall only. Additional temporary and permanent bracing MiTek* Is always required for stability and to prevent collapse with possible personal Injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, seeANSVIPII Quality Criteria, DSB-89 and BCSI BuNdIng Component 6904 Parke East Blvd. Safety Informatlanovallable from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314. Tampa, Fl- 33610 Job Truss Truss Type i# 1 0 Q Ply ACQUAVISTA. T1556056 � I 75575 B4 Roof Special Jot Uhambers I russ, Inc., Ir-on Herce, r-L 1- 1 2-0 7-8-6 1-6 0 7-8-6 5.00 r1_2 24 2 3x6 = u.iju s mar ii zuio mi ieK inausines, Inc. mon Nov iz uv:jts:4z zuin rage i 3-5-5 5x6 = 5X8 4 26 5 5X8 MT1 BHS = 5X8 MT1 BHS 3X4 6 3 25 W_� 17 16 15 14 13 12 11 3X4 11 4x6 = 3x6 3x4 4x6 3X4 3x8 4-10-11 1-6-0 ' Scale = 1:62.9 3X4 7 8 9 07 I'T 0 3X8 13-0-0 17-8 0 1 0 8-0 35-0-0 5-3-10 4-8-0 4. ;4 _6 8-4-0 Plate Offsets (X,Y)-- [2:0-0-6,Edqel,[4:0-3-0,0-2-41,[5:0-5-4,0-2-41,[7:0-5-12,0-2-81,[9:0-0-0,0-0-21 LOADING (pso SPACING- 2-0-0 CSI. DEFL. in (loc) I/clef] Ud PLATES GRIP TCLL 20.0 Plate Grip DOL 1.25 TC 0.76 Vert(LL) -0.19 13-14 >999 360 MT20 244/190 TCDL 15.0 Lumber DOL 1.25 BC 0.62 Vert(CT) -0.44 13-14 >952 240 MT18HS 244/190 BCLL 0.0 Rep Stress Incr YES WB 0.96 Hor-z(CT) 0.14 9 n/a n/a BCDL 10.0 Code FBC2017fTP]2014 Matdx-MS Wind(LL) 0.43 13-14 >979 240 Weight: 182 Ito FT = 20% LUMBER- BRACING- TOPCHORD 2x4 SP M 30 TOPCHORD Structural wood sheathing directly applied or 3-4-6 oc purlins. BOTCHORD 2x4 SP M 30 BOTCHORD Rigid ceiling directly applied or 3-11 -1 oc bracing. WEBS 2x4 SP No.3 REACTIONS. (lb/size) 2=1680/0-8-0,9=1680/0-8-0 Max Horz 2=-322(LC 10) Max Uplift 2=-1540(LC 12), 9=-1.540(LC 12) FORCES. (lb) -Max. Comp./Max. Ten. -All forces 250 (lb) or less except when shown. TOPCHORD 2-3=-3356/3381, 3-4=-2667/2831, 4-5=-2480/2735, 5-6=-2815/3018, 6-7=-3650/3926, 7-8=-3164/3341, 8-9=-3483/3737 BOTCHORD 2-17=-2873/3028, 15-17=-2873/3028, 14-15=-2242/2,533, 13-14=-3�08/3608, 11 - 1 3=-2729/2864, 9-11 =-3287/3179 WEBS 3-17=-1 5/295, 3-1 5=-896/954, 4-15=-695/726, 5-14=..925/942, 6-14L1 410/1598, 6-13=-550/689, 7-13=- 10 17/943, 7-11 =-279/38 1, 8-11 =_438/644, 5]15=-402/396 NOTES- 1 ) Unbalanced roof live loads have been considered for this design. 2) Wind: ASIDE 7-10; Vult=170mph (3-second gust) Vasd=132mph; T(,DL=4.2psf; B�CDL=3.Opsf; h=33ft; B=53ft; L=65ft; eave=7ft; Cat. 11; Exp D; Encl., GCpi=0.18; MWFRS (directional) and C-C Exterior(2) -1-6-0 to 4-111-13, Interion(l) 4-11-13 to 13-0-0, Exterior(2) 13-0-0 to 17-8-0, Interior(l) 22-4-0 to 36-6-0 zone;C-C for members and forces & FRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) Provide adequate drainage to prevent water ponding. 4) All plates are MT20 plates unless otherwise indicated. 5) This truss has been designed for a 10.0 lost bottom chord live load nonconcurrent th any other live loads. 6) * This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. i 7) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) except at=lb) 2=1540,9=1540. Walter P. Finn.PE No.22839 III USA, Inc. Fl. Cort 6634 6904 Parke East Blvd. Tampa FL 33610 QaW November 12,201 E ,& WARNING - Verify design parameters and READ NOTES ON THIS AND iNcLuDED mrrEK REFERANCE PAGE 11111-7473 rev. 1010312015 BEFORE USE. Design valid for use only with M1Tek@ connectors. This design Is based only upon parameters sr own and Is for an Individual building component, nc a truss system. Before use, the building designer must verify the applicability of nd properly Incorporate this design Into the overall 8 design '.r.me� building design. Bracing Indicated Is to prevent buckling of Individual truss web and/or chorcirnembers only. Additional temporary and permanent bracing MiTek' Is always required for stability and to prevent collapse with possible personal Injury and property damage. For general guidance regarding the . c fabrl aflon, storage, delivery, erection and bracing of trusses and truss systems, seeANSIfrPII Qu Criteria, DSB-89 and Iii Building Component. 6904 Parke East Blvd. Safe 22 4. ty Informationovailable from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria VAIT11 Tampa, FL 33610 Job Tru s Truss Type Qty. Ply ACQUAVISTA T15560568 75575 B5 Roof Special 1 1 Job Reference (optional) UlriarnDem I russ, Inc., t-ort t-ierce, t-L C' 2 0. IOU 5 IvIdr 1 1 4U I a Ivil I UA H Iuubulub, 11—i" "'Uv ­ ­­­ ­ I. '.V. I iXTOZhc4Bay—yKyKq-viCAiHnzCRM?YJBYaZ7XFHSOU—TUduMteq1 buTyJz7v 24-4-0 28-8-0 35-0-0 , .36-6-0. Scale = 1:62.9 7 9 107 17 16 16 14 13 12 11 3X4 11 4x6 US 3x4 11 3x4 3x6 3x6 3XB 5xB MT1 8HS 7-8-4 11-0-0 1 9-8-b 24-4-0 28-8-0 35-0-0 7-8-4 3-3-12 4-4-0 4-4-0 4-8-0 4-4-0 Sx6 3x4i= 5X15 4 26 527 2B '6 5.00F1_2 3X4 — 5x8 MT1 8HS 6X — 3 6xB 25 7 29 24 _-5��3 z 7-8-4 1 3-3-12 . B-8-0 4-8-0 4-4-0 6-4-U Plate Offsets (X,Y)-- [2:0-0-6,Edqel,[4:0-3-0,0-2-41,[6:0-3-12,0-2-8l,r7:0-5-4,0-3-01�[8:0-4-0,0-1-131,[9:0-0-6,EdgeI LOADING (pso SPACING- 2-0-0 CS1. DEFL. in (loc) I/clefl Ud PLATES GRIP TCLL 20.0 Plate Grip DOL 1.25 TC 0.77 Vert(LL) -0.22 12-14 >999 360 MT20 244/190 TCDL 15.0 Lumber DOL 1.25 BC 0.68 Vert(CT) -0.54 14-16 >780 240 MT18HS 244/190 BCLL 0.0 Rep Stress Incr YES WB 0.96 Horz(CT) 0.15 9 n/a n/a BCDL 10.0 Code FBC2017ITP12014 Matrix -MS Wind(LL) 0.49 12-14 >850 240 Weight: 175 lb FT = 20% LUMEIER- BRACING - TOP CHORD 2x4 SP M 30 TOPCHORD Structural wood sheathing directly applied or 3-2-9 oc purlins. BOTCHORD 2x4 SP M 30 BOTCHORD Rigid ceiling directly applied or 3-5-13 oc bracing. WEBS 2x4 SP No.3 REACTIONS. (lb/size) 2=1680/0-8-0,9=1680/0-8-0 Max Horz 2=277(LC 11) Mix Uplift 2=-1 540(LC 12), 9=-1 540(LC 12) FORCES. (lb) -Max. Comp./Max. Ten. -All forces 250 (lb) or less except when shown. TOPCHORD 2-3=-3341/3458, 3-4=-2862/3102, 4-5=-2648/2929, 5-6=-3007/332d, 6-7=-3232/3445, 7-8=-3169/3457, 8-9=-3412/3552 1 BOTCHORD 2-17=-2927/3004,16-17=-2927/3004,14-16=-2709/2921,12-14=-4 03/4318, 11-12=-4299/4320,9-11=-3041�/3077 WEBS 3-16=-720/858, 4-16=-941/936'.5-16=-590/6B9,6-14=-897/910, 7-1 =-1623/1851, 7-11 =-1 417/1443, B-1 1 =.-841/924 NOTES- 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-10; Vult=170mph (3-second gust) Vasd=132mph; TCDL=4.2psf; BCDL=3.Opsf; h=33ft; B=53ft; L=65ft;.eave=7ft; Cat. 11; Exp D; Encl., GCpi=0.18; MWFRS (directional) and C-C Exterior(2) -1-6-0 to4-111-13, Interior(l) 4-11-13 to 11-0-0, Exterior(2) 11-0-0 to 24-4-0, Interior(l) 24-4-0 to 36-6-0 zone;C-C for members and forces& WFRS for reactions shown; Lumber DOL=1.60 plate grip DCL=11.60 3) Provide adequate drainage to prevent water ponding. 4) All plates are MT20 plates unless otherwise indicated. 5) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 6) *. This truss has been designed for a live load of 20.Opsf on the bottom chord in all I areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 7) Provide mechanical connection (by others) of truss to bearing plate capable of wit standing 100 lb uplift at joint(s) except at=lb) 2=1540,9=1540. 1 ,& WARNING - Verify design parameters and READ NOTES ON THISANDINCLUDED mrTEK REFERAkcE PAGE 11111-7473 rev. 1010312016 BEFORE USE. Design valid for use only with IvITek@ connectors, This design Is based only upon parameters sh6wn, and Is for an Individual building compo6ent, not a truss system. Before use, the building designer mustverlfy theppplicablllty of design paromet6ts and properly Incorporate this design Into the overall building design. Bracing Indicated Is to prevent buckling of Individual truss web and/or chord tembers only. Additional temporary and permanent bracing Is always required for stability and to prevent collapse with possible personal Injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, seeANSVMII QiiiIallty Criteria, DSB-69 and BCSI Building Componant Safety Inforimationavallable from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA, 22314. Walter P. Finn, PE No.22839 Mi rek USA, Inc. FL Cert 6634 6904 Parke East Blvd. Tampa FL 33610 DaW November 12,2018 M!Tek' 6904 Parke East Blvd. Tampa, IFIL 33610 Job Tru S Truss Type Qty: Ply ACQUAVISTA. T15560569 75575 B6 Roof Special 1 1 . Job Reference (optional) K— hi— 4n nn 00 AA OAID- D i Chambers Truss, Inc., 6-01 Fort Pierce, FL 5-:-1 -0-0 15-4-0 U.— M., i 1 —.6-1 6 n U ii— M � ID:aNkrWfLwRDXTOZhc4Bay—yKyKc(-N3mYwdocz]UsAS117GemnV—CaNmMMLROsUngQwyJz7v 21-8-0 -4-0 `0 500 36-6-0 1.6 0 _1 2 6-4 .0 .0 4 4 6-4-0 80 Scale 1:62.9 5x8 MT1 BHS 3x4 11 5x8 MT1 BHS 5.00 FiT 4 526 27 6 3 3x4 -Z� X4 0 MT18H 5x121 -6xlOMT18HS= 5xl2MT18HS= 25 3 7 8 24 2 9 9 1017 17 16 15 14 13 12 11 3x6 3x4 4x6 3XB 4x5 4x8 3x4 11 3x8 5x8 MT1 8HS — LOADING (psf) SPACING- 2-0-0 CS1. DEFL. in (loc) . I/def] Ud PLATES GRIP TCLL 20.0 Plate Grip DOL 1.25 TC 0.75 Vert(LL) -0.29 12-14 >999 360 MT20 244/190 TCDL 15.0 Lumber DOL 1.25 BC 0.84 Vert(CT) -0.67 12-14 >631 . 240 MT18HS 244/.190 BCLL 0.0 Rep Stress Incr YES WB 0.90 Horz(CT) 0116 9 n/a n/a BCDL 10.0 Code FBC2017frPI2014 Matrix -MS Wind(LL) 0.66 12-14 >635 240 Weight: 172 lb FT 20% LUIMBER- BRACING- TOPCHORD 2x4 SP M 30 TOPCHORD Structural wood sheathing directly applied or 2-9-12 oc purlins. BOTCHORD 2x4 SP M 30 BOTCHORD Rigid ceiling directly applied or 3-0-5 oc bracing. WEBS 2x4 SP No.3 WEBS 1 Row at midpt 4-15,7-14 REACTIONS. (lb/size). 2=1680/0-8-0,9=1680/0-8-0 Max Horz 2=-233(LC 10) Max Uplift 2=-1 540(LC 12), 9=-1 540(LC 12) FORCES. (lb) - Max. Conri Ten All forces 250 (lb) or less except when sho Nn. TOPCHORD 2-3=-3406/3592, 3-4=-3081/3233, 4-5=-3634/3903, 5-6=-3634/390'c, 6-7=-3748/3887, 7-8=-5402/5644, B-9=-3551/3626 BOTCHORD 2-17=-3093/3103,15-17=-2552/2810,14-15=-3211/3456,12-14=-5 t37/5474, 11 - 1 2=-3140/3236, 9-11 =-313813228 WEBS 3-17=-453/664, 4-17=-342/448, 4-15=-1 053/1054, 5-15=-506/693, E -1 5=-290/413, 6-14=-870/945, 7-14=-2211/2420, 7-12=-925/1065, 8-12=-2419/2367 NOTES - I ) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-10; Vult=170mph (3-second gust) Vasd=132mph; TCDL=4.2psf; BCDL=3.Opsf; h=33ft; B�53ft; L=65ft; eave=7ft,* Cat.- 11; Exp D; Encl., GCpi=0.18; MWFRS (directional) and C-C Exterior(2) -1-6-0 to 4-i 1-13, Interior(l) 4-11-13 to 9-0-0, Extedor(2) 9-0-0 to 26-4-0, Interior(l) 26-4-0 to 30-8-0 zone;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) Provide adequate drainage to prevent water poncling. 4) All plates are MT20 plates unless otherwise indicated. 5) This truss has been designed for a 10.0 psf bottom chord live load nohconcurrent Nith any other live loads. 6) * This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. , - 7) Provide mechanical connection (by others) of trus's to'bearing plate capable of withstanding 100 lb uplift at joint(s) except Gt=lb) 2=154o,9=1540. I Walter P. Finn. PE No.22839 MiTek USA, ln'e. FL Cent 6634 6904 Parke East Blvd. Tampa FL 33610 Date'. November 12,2018 wARNiNr. - Verify design parameters and READ NOTES ON THIS AND INCLUDED 1141TEK REFERANCE PAGE Mll-7473 rev. 10103)2015 BEFORE USE. Design vold for use only with Mffek(g) connectors. This design Is based a . nly upon parameters shown, and Is for an Individual building component, not a truss system. Before use, the building designer must verity the applicability of design parameters and properly Incorporate this design Into the overall building design. Bracing Indicated Is to prevent buckling of Individual truss wet, and/or chord Members only. Additional temporary and permanent bracing MiTek' Is always required for stability and to prevent collapse with possible personal injury and properiy damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, seeANSYPII Qualtlilir Criteria. DS113-89 and BCSI Building Component Salloty Informationavalloble from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria. V� 22314. 6904 Parke East Blvd. Tampa, FL 33610 Job Truss Truss Type Qty Ply ACQUAVISTA T15560570 75575 C Common 2 Job Ghambers I russ, Inc., Fort Ilierce, FL 6-11-2 6-11--2 5.00 F1_2 17 16 2 3x5 mious iviaT I 1 41.110 M11BK inuusines, inu. mun iN[uv ieuv;13o;-+o4u10 rdye I 10.0.0 ID:aNkrWfLwRDXTOZhc4Bay—yKyKq-rGKx7zpEk2cjocHxh-9?KiXQAnAY5xfA58XiyMyJz7u L, --0-- —1, 20-0-0 1 '--0 3-0-14 '.0." 6-11-2 Ll� -0 Scale = 1:36.9 4x4 4 2X3 'I, 2X3 1' ___> 5 3 1 1 � 9 3x6 3818 18 19 6 3x5 = Plate Offsets (X,Y)-- [2:0-0-6,Edgel, r6:0-0-6,Edgel LOADING (pso SPACING- 2-0-0 CS1. DEFL. in (loc) I/defl Ud PLATES GRIP TCLL 20.0 Plate Grip DOL 1.25 TC 0.50 Vert(LL) -0.14 8-15 >999 360 MT20 244/190 TCDL 15.0 Lumber DOL 1.25 BC 0.58 Vert(CT) -0.34 8-15 >715 240 BCLL 0.0 Rep Stress Incr YES WB 0.33 Horz(CT) 0.03 6 n/a n/a BCDL 10.0 Code FBC2017/TP[2014 Matrix -MS Wind(LL) 0.17 8-15 >999 240 Weight: 85 lb FT = 20% LUMBER- BRACING- TOPCHORD 2x4 SP M 30 TOPCHORD Structural wood sheathing directly applied or 5-2-1 oc purlins. BOTCHORD 2x4 SP M 30 BOTCHORD Rigid ceiling directly applied or 5-11-15 oc bracing. WEBS 2x4 SP No.3 REACTIONS. (lb/size) 2�1005/0-8-0,6=1005/0-8-0 Max Harz 2=-255(LC 10) Max Uplift 2=-962(LC 12), 6=-962(LC 12) FORCES. (lb) -Max. Comp./Max. Ten. -All forces 250 (lb) or less except when shoyvn. TOPCHORD 2-3=-1 668/1693, 3-4=-1 373/1391, 4-5=-1 373/1391, 5-6=-1 668/1692 BOTCHORD 2-8=-1 316/1472, 6-8=-1 37111482 WEBS 4-8=-943/971, 5-8=-5371775, 3-8=-5381776 NOTES- 1 ) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-10; Vult= 170mph (3-second gust) Vasd=132mph; TCDL=4.2psf; BCDL�3.0psf; h=33ft; B=53ft; L=65ft; eave=7ft; Cat. 11; Exp D; Encl., GCpi=0.18; MWFRS (directional) and C-C Exterior(2) -1-6-OW4 1-13,lnte(jor(1)4-11-13tolO-O-O,Exterior(2) 10-0-0 to 16-5-13 zone;C-C for members and forces & MWFRS I X; Lumber DOL=1.60 plate grip DOL=1.60 3) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent 6th any other live loads. 4) * This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 5) Provide mechanical connection (by others) of truss to bearing plate capable at wit tanding 100 lb uplift at joint(s) except at=lb) 2=962,6=962. 'Is 7 11 T. 0 Walter P. Finn PE No.22839 MiTek USA, Inc. FL Cart 6634 6904 Parke East Blvd. Tampa FL 33610 Date: November 12,2018 WARNING- Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERANCE I PAGE 11111-7473 rev. 10/03)2015 BEFORE USE Design valid for use only with MITek@ connectors. This design Is based only upon parameters shown, and Is for on Individual building c6mponent not a truss system. Before use, the bullding designer must verify the applicability of design parametbrs and properly Incorporate this design Into the overall building design. Bracing Indicated Is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing Mek' Is always required for stability and to prevent collapse with possible personal Injury and proper� damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of tfusses and truss systems, seeANSVMII Quality Criteria, DS11.69 and BCSI Bulildling Component 6904 Parke East Blvd. Salloty Informatlanovallable from Truss Plate lnstitute� 218 N. Lee Street, Suite 312, Alexandria, VA, 22314. Tampa, FL 33610. Job Tru s Truss Type A Qty Ply ACQUAVIS TA . T15560571 75575 C1 Hip 1 �nal) L;namDers I russ, Inc., ron vierce, M 1 -1-6-0 . 5-8-12 2 3x5 = 5.00 F12 2x3 Z'� 18 9-0-0 4X4 -- 4 11 1 1 0 3x6 = q.1 0. 1 JU 5 Mar I I 4U 10 IVII I eK 111OUbtrieU, 111U. IVIUI I 111UV I e UU;'30;-+0 4V 10 rdye I ID:aNkrWfLwRDXTOZhc4Bay—yKyKq-JSuJLJqsVMIaPms7FhgEsw4cwBZOqQSJKoGFUoyJz7t _0 4-'-4 20-0-0 1`0 1 �3.3-'� 1 5-8-12 ! 11-0-0 4x4 5 9 '3X4 Scale 1:37.5 2x3 5;, 6 19 7 7 7 8 8 17 0 3X5 LOADING (psf) SPACING- 2-0-0 CS1. DEFL. in (loc) I/def] Ud PLATES GRIP TCLL 20.0 Plate Grip DOL 1.26 TC 0.44 Vert(LL) -0.12 9-17 >999 360 MT20 244/190 TCDL 15.0 Lumber DOL 1.25 BC 0.44 Vert(CT) .-0.28 9-17 >854 240 BCLL 0.0 Rep Stress Incr YES WB 0.23 Horz(CT) 0.04 7 n/a n/a BCDL 10.0 Code FBC20171TP12014 Matrix -MS Wind(LL) 0.15 9-17 >999 240 Weight: 89 lb FT = 20% LUMBER- IBRACING- TOPCHORD 2x4 SP M 30 TOPCHORD Structural wood sheathing directly applied or 5-2-13 oc purlins. BOTCHORD 2x4 SP M 30 BOTCHORD Rigid ceiling directly applied or 5-8-8 oc bracing. WEBS 2x4 SP No.3 REACTIONS. (lb/size) 2=1005/0-8-0,7=1005/0-8-0 Max Horz 2=233(LC 11) Max Uplift 2=-962(LC 12), T=�-962(!_C 12) FORCES. (lb) -Max. Comp./Max. Ten. -All forces 250 (lb) or less except when shown. TOP CHORD 2-3=-1736/1905, 3-4=-1404/1499, 4-5=-1302/1438, 5-6=-1404/149E, 6-7=-1735/1905 BOTCHORD 2-1 0=-1 542/1565, 9-1 0=-930/1191, 7-9--L-1 560/1562 WEBS 3-1 0=-514/773, 4-1 0=-372/402, 5-9=-372/402, 6-9=-515f773 NOTES- 1 ) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-10; Vult=170mph (3-second gust) Vasd=132mph; TCDL=4.2psf; BCDL=3.Opsf; h=33ft; B=53ft; L=65ft; eave=7ft; Cat. 11; Exp D; Encl., GCpi=0.18; MWFRS (directional) and C-C Exterior(2) -1-6-0 to 4-1.1-13, Interior(l) 4-11-13 to 9-0-0, Exterior(2) 9-0-0 to 11-0-0, Interior(l) 20-0-Oto 21-6-0 zone,C-C for members and forces& MWFR for reactions shown; Lumber DOL=1.60 plate grip DOL=11.60 3) Provide adequate drainage to prevent water poncling. 4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 5) * This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift atjoint(s) except Gt=lb) 2=962,7�_962. . : I Walter P. Finn.PE No.22839 MiTek USA, Inc. FL Carl 604 6904 Parke East Blvd. Tampa FIL 33610 Date: November 12,2018 ,& WARNuir- Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEKREFERA CE PAGE MIP7473 rev. 10/03)2015 BEFORE USE. Design valid for use only with MiTek@ connectors. This design Is based only upon parameters shown, and Is for an Individual building component not altruss system. Before use, the building designer must verify the applicability of design parometbrs building design. Bracing Indicated Is to prevent buckling of Individual truss web and/or chord and properly Incorporate this design Into the overall tembers only. Additional temporary and permanent bracing MiTek' is always required for stability and to prevent collapse with possible personal Injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems. seeANSVIIFII Quality Safety Informationavallable from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA Citledia. DSB-89 and BCSII Building Component 22314. 6904 Parke East Blvd. Tampa, FL. 33610 Job Truss Truss Type Qty Ply ACQUAVISTA. T15560572 75575 E MONOPITCH 6 1 Job Reference (optional) L,naMDers i russ, inc., ran rierce, l­L 2 0 3x4 = 5.00 ti.ious mar ii zuitj miieK inclusines, mc.,mon ijov iz uumb:4t zuits rage i ID:aNkrWfLwRDXTOZhc4Bay—yKyKq-oeShYfqUGgtRlwRKpPBTP7cqFb?EZvxTZSOplEyJz7s Scale 1:10.6 3 4 9 4 3X4 LOADING (psf) SPACING- 2-0-0 CS1. DEFL. in (loc) I/defl Ud PLATES GRIP TCLL 20.0 Plate Grip DOL 1.25 TC 0.21 Vert(LL) 0.00 8 >999 240 MT20 244/190 TCDL 15.0 Lumber DOL 1.25 BC 0.06 Vert(CT) -0.00 8 >999 240 BCLL 0.0 Rep Stress Incr YES WB 0.09 Horz(CT) -0.00 9 n/a n/a BCDL 10.0 Code FBC2017/TP12014 Matrix -MR Weight: 12 lb FT = 20% LUMBER- BRACING - TOP CHORD 2X4 SP M 30 TOPCHORD Structural wood sheathing directly applied or 2-8-0 oc purlins, BOT CHORD 2x4 SP M 30 except end verlicals. WEBS 2x4 SP No.3 BOTCHORD Rigid ceiling directly applied or 10-0-0 oc bracing. OTHERS 2x4 SP No.3 REACTIONS. (lb/size) 2=248/0-8-0,9=57/0-3-8 Max Horz 2=170(LC 12) Max Uplift 2=-412(LC 12), 9=-98(LC 9) FORCES. (lb) -Max. Comp./Max. Ten. -All forces 250 (lb) or less except when sho vn. NOTES- 1) Wind: ASCE 7-10; Vult=170mph (21-second gust) Vasd=132mph; TCDL=4.2psf; BCDL7:3.Opsf; h=33ft; B=53ft; L=65ft; eave=7ft; Cat.. 11; Exp D; Encl., GCpi=O. 18; MWFRS (directional) and C-C Exterior(2� zone; porch left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL:�:1.60 plate grip DOL=1.60 1 2) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 3) *This truss has been designed for alive load of 20.Opsf on the bottom chord in all r6as where a rectangle 3-6-0 tall by2-0-0 wide will fit between the bottom chord and any other members. 4) Bearing at joint(s) 9 considers parallel to grain value using ANSlfTPl I angle to grac in formula. Building designer should verify capacity of bearing surface. - 5) Provide mechanical connection (by others) of truss to bearing plate capable of witl­ standing 100 lb uplift at joint(s) 9 except Ot=lb) 2=412. Walter P. Finn. PE No.22839 MiTek USA, Inc. FL Cart 66U 6904 Parke East Blvd. Tampa FL 33610 Date - November 12,2018 WARNING -Verily design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERANCE PAGE MX7473 rev. 101103V2015 BEFORE USE. Design valid for use only with MITek@ connectors. This design Is based only upon parameters'sho , wn, and Is for an Individual building component not a truss system. Before use, the building designer must verify the applicability of design paramet6rs and properly Incorporate this design Into the overall building design. Bracing Indicated is to prevent buckling of individual truss web and/or chord r�embers Is always required for stability and to prevent collapse with possible personal Injury and properN, only. Additional temporary and permanent bracing damage. For general guidance regarding the MiTek' fabrication, storage, delivery, erection and bracing of trusses and truss systems, seeANSVTP11 Q4ollly Cdtoda. DSB-89 and BCSI flullding Component 6904 Parke East Blvd. Safety Informationavailable from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VAI 22314. Tampa, FL 33610 Job Truss Truss Type Qty Ply ACQUAVISTA T15560573 75575 FLA Floor 10 1 Job Reference (optional) Chambers I russ, Inc., ron Pierce, FL 8.130 s Mar 11 2018 MiTek ndustrie5, Inc. Man Nov 12 09;38;48 2016 raye i ID:aNkrWfLwRDXTOZhc4Bay—yKyKq-GqO3m?r6lz?lf4OWM6iiyL9s5?7RIEDcn6lMZhyJz7r 0-3-8 HI 2-6-0 ?:Z4 2-0-0 k 0 8 le 1:42.4 3x4 6xB 6x8 US 4x4 4x4 3x6 FP 4x5 3x4 1 2 3 4 5 6 7 8 9 10 11 12 13 14 is 919 I lu. 0 24 23 22 21 20 19 18 17 16 5x12 4x8 3x6 FP 4x4 48 5x12 5x12 MT18HS SP 4x4 L 13-6-8 LOADING (psl) SPACING- 2-0-0 CSI. DEFL. in ([cc) I/defl Ud PLATES GRIP TCLL 40.0 Plate Grip DOL 1.00 TC 0.78 Vert(LL) -0.31 19-20 >948 480 MT20 244/190 TCDL 20.0 Lumber DOL 1.00 BC 0.89 Vert(CT) -0.50 19-20 >583 360 MT1BHS 244/190 BCLL 0.0 Rep Stress Incr YES WB 0.60 Horz(CT) -0.10 15 n1a n/a BCDL 5.0 Code FBC2017fTP12014 Matrix-S Weight: 140 lb FT = 20%F, I 1%E LUMIBER- BRACING - TOP CHORD 2x4 SP M 30(flat) TOPCHORD BOT CHORD 2x4 SP M 30(flat) WEBS 2x4 SP No.3(flat) *Except* BOTCHORD 1-23,15-17: 2x4 SP M 30(flat) REACTIONS. (lb/size) 1=1568/0-3-0, 15=156B/0-3-0 FORCES. (lb) -Max. Comp./Max. Ten. -All forces 250 (lb) or less except when shown. TOPCHORD 1-3=-1 999/0, 3-4=-1 964/0, 4-5=443121/0, 5-6=-4438/0, 6-7=-5017/0, 7-8=-5017/0, 8-9=-5017/0,9-11=-4438/0,11-12=-4438/0,12-13=-1994/0113-15=JI1999/0 BOTCHORD 22-23=0/3428, 20-22=0/4955,19-20=0/5017,18-19=0/4955,17-18=,0/3428 WEBS 7-20=-543/226, 8-19=-543/226,1-23=0/2423, 3-23=-290/0, 4-23=-17,77/0, 4-22=0/1252, 5-22=-315/0, 6-22=-749/0, 6-20=-3091694,15-17=0/2423,13-17=-290/0,12-17=-1777/0, 12-18=0/1252,11-18=-315/0, 9-18=-749/0, 9-19=-309/694 1 Structural wood sheathing directly applied or 5-7-6 cc purlins, except end verticals. Rigid ceiling directly applied or 10-0-0 cc bracing. NOTES- i) Unbalanced floor live loads have been considered for this design. 2) All plates are MT20 plates unless otherwise indicated. 3) All plates are 2x3 MT20 unless otherwise indicated. 4) The Fabrication Tolerance at joint 21 = 11 % 5) Recommend 2x6 strongbacks, on edge, spaced at 10-0-0 cc and fastened to eacl� truss with 3-1 Od (0. 131" X 3") nails. Strongbacks to be attached to walls at their outer ends or restrained by other means. 6) Gap between inside of top chord bearing and first diagonal or vertical web shall noill, exceed 0.500in. Walter P. Finn. PE No.22839 MiTek USA, Inc. FL Cart 6634 6904 Parke East Blvd. Tampa FL 33610 Date; November 12,2018 WARNING - Verity design parameters and READ NOTES ON THIS AND INCLUDED MffEK REFERANCE PAGE 11,111-7473 rev. 101031201S BEFORE USE. Design valid for use only with MITek@ connectors. This design Is based only upon parameters sho�vn, and Is for an Individual building component, not wt a truss system. Before use, the building designer must verity the applicability of design paramete'rs and properly Incorporate this design Into the overall building design. Bracing Indicated Is to prevent buckling of Individual truss web and/or chord rdembers only. Additional temporary and permanent bracing M!Tek'- Is always required for stability and to prevent collapse with possible personal Injury and property1damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, se9ANSVWl1 Quality Criteria, DSB-69 and BCSI Building Component 6904 Parke East Blvd. Safety Informationavallable from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VAI 22314. - Tampa, FL 33610 Job Truss Truss Type Qty Ply ACQUAV ISTA T15560574 75575 FLB Floor 2 Job Refereno Chambers Truss, inc., Fort Pierce, FL 8.11,50 s mar i 1 2018 MIT ek inausines, Inc. Man Nov 12 09;38;49 2016 rage I ID:aNkrWfLwRDXTOZhc4Bay—yKyKq-k1 aRzLskoH78GEbiwqExUyi7sOVJ1 cj[OmVv57yJz7q 0-3-8 1 2-6-0 1 0-11-8 2-0-0 soi:U daid = 1:34.8 6x6 3x4 3x4 3x4 3x4 3x6 FP 3x4 3x4 6x8 1 2 3 4 5 6 7 8 9 10 11 12 13 C C 9 d 9 9 6 CP 21 20 19 18 17 16 15 14 4xl 0 3x5 3x5 4xl 0 0 9-3-0 10 3 1 111 ;1-.1 20-2-B 29-60 OE23-4 B-11-8 OL3-8 Plate Offsets (X,Y)-- [1:0-1 -8, Edgel, [6:0-1-8, Ed -gel, 17:0-1-8, Edge], 1 3:0-1-8,Edqel� [14:0-1-8, Ed_qel, rl 7:0-1-8,0-0-01, rl 8:0-1-8, Ed_qel LOADING (psf) SPACING- 2-0-0 CS1. DEFL. in (loc) I/defl Ud PLATES GRIP TCLL 40.0 Plate Grip DOL 1.00 TC 0.39 Vert(LL) -0.15 18-19 >999 480 MT20 244/190 TCDL 20.0 Lumber DOL 1.00 BC .0.72 Vert(CT)- -0.24 17-18 >980 360 BCLL 0.0 Rep Stress Incr YES WB 0.93 Horz(CT) -0.06 13 n/a n/a BCDL 5.0 Code FBC2017frPI2014 Matrix-S Weight: 118 lb FT = 20%F, I I %E LIUMBER- BRACING- TOPCHORD 2x4 SP M 30(flat) TOPCHORD Structural wood sheathing directly applied or 6-0-0 oc purlins, BOTCHORD 2x4 SP M 30(flat) except end verticals. WEBS 2x4 SP No.3(flat) BOTCHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS. (lb/size) 1=1286/0-3-0,13=1286/0-3-0 FORCES. (lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOPCHORD 1-3=-1 605/0, 3-4=-1 600/0, 4-5=-3262/0, 5-6=-3262/0, 6-7=-33 , -8=-3262/0, 8-10=-3262/0, 10-11=-1600/0,11-13=-1605/0 BOTCHORD 19-20=0/2653,18-19=0/3368,17-18=0/3368,16-17=0/3368,15-16=10/�2653 WEBS 1-20=0/1944,3-20=-29810,4-20=-1305/0,4-19=0/755,5-19=-31 5 6-19=-578170, 13-15=011944,11-15=-298/0,10-15=-1305/0,10-16=0[75518-16=- 12/53, 7-16=-578/170 NOTES- 1).Unbalanced floor live loads have been considered for this design. 2) All plates are 2x3 MT20 unless otherwise indicated. 3) Recommend 2x6 strongbacks, on edge, spaced at 10-0-0 oc and fastened to eacl) truss with 3-1 Od (0.131 X 3") nails. Strongbacks to be attached to walls at their outer ends or restrained by other means. 4) Gap between inside of top chord bearing and first diagonal or vertical web shall not, exceed 0.500in. Walter P. Finn PE No.22839 MiTek USA, Inc. K Cent 66 34 6904 Parke East Blvd. Tampa FL 33610 Date: WARNING -Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEKREFERANCE PAGE M11-7473 rev. 10103,2015 BEFORE USE. Design valid for use only with MiTek@ connectors. This design Is based only upon parameters shown, and Is for an Individual building component not a truss system. Before use, the building designer must verify the applicability of design parameters and properly Incorporate this design into the overall building design. Bracing indicated Is to prevent buckling of Individual truss web and/or chord rr�embers only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal Injury and prcpe�), domage�, For general guidance regarding the MiTek' fabrication, storage, delivery, erection and bracing of trusses and truss systems, seeANSVrPI1 Quality Cifforlo, DSB-89 and BCSI Building Component 6904 Parke East Blvd. Safety Informationovallable from Truss Plate Institute, 218 N. Lee Street Suite 312, Alexandria, VA 22314. Tampa, FL 33610 Job Truss Truss Type Qty Ply AC QUAVISTA T15560575 � 75575 FLC Floor 7 1 Job Reference (optional) Unambers I russ, Inc., t-ort merce, I­-L 0-3-8 H 1 2-6-0 5X6 11 3X4 W 11 1 2 3 C q 16 15 2x3 11 4x10 3x4 4 miju s mar I I ZU 10 Wit 18K inausines, inc. rviun niuv iz uu;ja;ou eu jo rdyu I ID:aNkrWfLwRDXTOZhc4Bay—yKyKq-CD7pAhtMZbF?uNAuUX]A1 mEJuotWm5JvFQETeZyJz7p 2-0-0 Sed a = 1:31.4 2X3 11 2X3 11 5 1 6 14 13 3x4 3x4 10-3-8 3x4 2x3 11 3X4 = 5x6 7 8 9 10 12 11 4x10 2X3 11 0 9 6 CP & LOADING (pso SPACING- 2-0-0 CSI. DEFL. in (loc) I/defl Ud PLATES GRIP TCLL 40.0 Plate Grip DOL 1.00 TC 0.37 Ven(LL) -0.21 14-15 >991 480 MT20 244/190 TCDL 20.0 Lumber DOL 1.00 BC. 0.60 Vert(CT) -0.29 14-15 >719 , 360 BCLL 0.0 Rep Stress Incr YES WB 0.81 Horz(CT) -0.04 10 n/a n/a BCDL 5.0 Code FBC2017fTP]2014 Matrix-S Weight: 101 lb FT= 20%F, ll%E LUMBER- EIRACING- TOP CHORD 2x4 SP M 30(flat) TOPCHORD Structural wood sheathing directly applied or 6-0-0 oc purlins, BOTCHORD 2x4 SP M 30(flat) except end verticals.' WEBS 2x4 SP No.3(flat) BOTCHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS. (lb/size) 1=1146/0-3-0,10=1146/0-3-0 FORCES. (lb) -Max. Comp./Max. Ten. -All forces 250 (lb) or less except when sho�n. TOPCHORD 1-3=-1 410/0, 3-4=-1 405/0, 4-5=-2686/0, 5-6=-2685/0, 6-7=-2685/0, 7-8=-1 405/0, 8-1 0=-1 410/0 BOTCHORD 14-15=0/2262, 13-14=0/2685, 12-13=0/2262 WEBS 5-1 4=-309/0, 6-13=-309/0, 1 -1 5=0/1 708, 3-15=-297/Cl, 4-15=-1 062/01 4-14=0/706, 10-12=0/1 708, 8-12=-297/0, 7-12=-1062/0, 7-13=01706 i NOTES- 1) Unbalanced floor live loads have been considered for this design. 2) Recommend 2x6 strongbacks, on edge, spaced at 10-0-0 oc and fastened to eac�� truss with 3-1 Od (0.131 3") nails. Strongbacks to be attached to walls at their outer ends or restrained by other means. 3) Gap between inside of top chord bearing and first diagonal or vertical web shall no�' exceed 0.500in. Walter P. Finn PE No.22839 MiTek USA, Inc. Fl. Cerl: 6634 .6904 Parke East Blvd. Tampa FL 33810 Vatic November 12.2018 ,& WARNING- Verify design parameters and READ NOTES ON THIS AND iNcLuDED mrTEK REFERANICE PAGE 11111-7473 rev. 1WO312015 BEFORE USE. Design valid for use only with MiTe1<@ connectors. This design Is based only upon parameters sho�tn, and Is for an Individual building component, net a truss system. Before use, the building designer must verify the applicability of design paramete , rs and properly Incorporate this design Into the overall building design. Bracing Indicated Is to prevent buckling of individual truss web and/or chord rriembers only. Additional temporary and permanent bracing MOW Is always required for stability and to prevent collapse with possible personal Injury and property1domage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, seeANSIMII Quality Ciftedo, DSB-89 and IIICSI Sulding Component. 6904 Parke East Blvd. Safety Informationavallable from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VAI 22314. Tampa, FL 33610 Job Tru s Truss Type City Ply ACQUAVIII TA T15560576 75575 FLD Floor 7 1 Job Reference (optional) (;naMbers I russ, Inc., Fort Pierce, FL t0ou s mar i i vulb mi i eK industries, inc. man Nov 12 09:36;51 Nits rage i ID:aNkrWfLwRD)CrOZhc4Bay—yKyKq-gPhCOlt?KuNsWX152FGPZznThCEZVY62U4—OAOyJz7o 0-3-8 2-6-0 2-2-0 2-0-0 2-2-0 013-P §cile 1:30.3 5x6 11 3x4 2x3 11 3x4 2X3 11 2X3 11 8x4 2x3 11 3x4 5x6 11 1 2 3 4 5 6 7 8 9 10 c 9 9 9 9 CU 16 15 14 13 12 11 2x3 I I 4xB 3x4 3x4 48 2x3 11 B-10-0 9-11-8 7-8-8 7-19-0 1 i 9 10,0 17-4-8 11-80 �3 7-5-0 0_11LB 1-0-0 N-8 A 1, 7-5-0 0-3-8 Plate Offsets (X,Y)-- [1:0-3-0, Edgel, [5:0-1-8, Edge], [6:0-1-8,0-0-01, [10:0-3-0, Edqel,i [I 10-1 -8, Edge], [1 3:0-1-8,Edgel, [14:0-1 -8, Edge] LOADING (psf) SPACING- 2-0-0 CS1. DEFL. in (loc) I/defI Ud PLATES GRIP TCLL 40.0 Plate Grip DOL 1.00 TC 0.43 VerI(LL) -0.18 14-15 >999 480 MT20 244/190 TCDL 20.0 Lumber DOL 1.00 BC 0.54 Vert(CT) -0.25 14-15 >824 360 BCLL 0.0 Rep Stress Incr YES WB 0.78 Horz(CT) -0.03 10 n/a n/a BCDL 5.0 Code FBC2017ITP[2014 Matrix-S Weight: 98 lb FT = 20%F, 1 1%E LIUIVIBER- BRACING - TOP CHORD 2x4 SP M 30(flat) TOPCHORD Structural wood sheathing directly applied or 6-0-0 oc purlins, BOTCHORD 2x4 SP M 30(flat) except end verticals. WEBS 2x4 SP No.3(flat) BOTCHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS. (lb/size) 1=1102/0-3-0,10=1102/0-3-0 FORCES. (lb) -Max. Comp./Max. Ten. -All forces 250 (lb) or less except when shown. TOPCHORD 1-3=- 1350/0, 3-4=-1 345/6, 4-5=-2480/0, 5-6=-2480/0, 6-7=-2480/0 1-8=- 1345/0, 8-1 0=- 1350/0 BOTCHORD 14-1 5=0/2138, 13-14=0/2480,12-13=0/2138 WEBS 5-14=-306/016-13=-306/0,1-15=0/1635,3-15=-305/0,4-15=-982/0,, -14=0/632,10-12=0/1635,8-12=-305/0, 7-12=-982/0, 7-13=0/632 NOTES- 1) Unbalanced floor live loads have been considered for this design. 2) Recommend 2x6 strongbacks, on edge, spaced at 10-0-0 oc and fastened to each truss with 3-10d (0.131 " X 3") nails. Strongbacks to be attached to walls at their outer ends or restrained by other means. 3) Gap between inside of top chord bearing and first diagonal or vertical web shali not iexceed 0.500in. I Walter P. Finn PE'No.22839 MiTek USA, Inc. FL Cart 6634 6904 Parke East Blvd. Tampa FL 33610 Date: . November 12,'2018 ,& WARNING - Verify design parameters andREAD NOTES ON THISAND INCLUDED MITEK REFERANCE PAGE 11,111-7473 11n, 1010312015 BEFORE USE. Design valid for use only with VITekO connectors. This design Is based only upon parameters show I n, and Is for an Individual building component, not a truss system. Before use, the building designer must verify the applicability of design poramete6,and properly Incorporate this design Into the overall building design. Bracing Indicated Is to prevent buckling of Individual truss web and/or chord members only. Additional temporary and permanent bracing MiTek* Is always required for stability and to prevent collapse with possible personal Injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, seeANSVWII Quality Cdtorlo,.DSB.89 and BCSI BuRding Component 6904 Parke East Blvd. SofotV [nfoffnationovallable from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 1 22314. Tampa, FL 33610 Job Truss Truss Type City Ply ACQUAVII TA T15560577 75575 FLE Floor 4 1 Job Reference (optional) Uhambers I russ, Inc., Fort Fierce, I-L i 2-6-0 2-0-14 15 3x6 d.i3u s mar ii zuit:; mi ieK inaustries, Inc. man NOV 1Z U9:Jt5:bX XUld t-age i ID:aNkrWfLwRDXTOZhc4Bay—yKyKq-BcFabMud5CVj7hKHbyne6BJe?cZ5EOcCikjaiSyJz7n 1-10-14 Scale = 1:29.1 3x5 2X3 3X4 2X3 3X4 2 3 1 4 5 6 7-6-14 LOADING (psf) SPACING- 2-0-0 TCILL -40.0 Plate Grip DOL 1.00 TCDL 20.0 Lumber DOL 1.00 BCLL 0.0 Rep Stress Incr YES BCDL 5.0 Code FBC2017/TP12014 14 13 3X8 2x3 11 12 3X4 16-10-! 7 1 1A 2X3 3X4 = 5XIS 11 7 8 9 11 10 4x8 2X3 0 0 6 c 1 6 '� CSI. DEFL. in (loc) I/defl Ud PLATES GRIP TC 0.40 Vert(LIL) -0.15 11-12 >999 480 MT20 244/190 BC 0.59 Vert(CT) -0.21 11-12 >956 360 WB 0.76 Horz(CT) 0.02 9 n1a n/a Matrix-S Weight: 97 lb FT = 20%F, 11 %E LUMBER- BRACING - TOP CHORD 2x4 SP M 30(flat) TOPCHORD Structural wood sheathing directly applied or 6-0-0 oc pudins, BOT CHORD 2x4 SP M 30(flat) except end verticals. WEBS 2x4 SP No.3(flat) BOTCHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS. (lb/size) 15=1084/Mechanical, 9=1013410-3-0 FORCES. (lb) -Max. Comp./Max. Ten. -All forces 250 (lb) or less except when shown. TOPCHORD 2-3=-2103/0, 3-4=-210310, 4-5=-2390/0, 5-6=-239010 6-7--1318/0 7 9=-1323/0 BOTCHORD 14-15=0/1312,13-14=0/2390,12-13=0/2390,11-12—�b/20�5 WEBS 5-12=-295/0, 2-15=- 1612/0, 2-14=0/980, 3-14=-327/0, 4-14=-589/0, 9-11 =0/1 602, 7-11 =-310/0, 6-11 =-950/0, 6-12=0/599 1 NOTES- 1) Unbalanced floor live loads have been considered for this design. 2) Refer to gircler(s) for truss to truss connections. 3) Recommend 2x6 strongbacks, on edge, spaced at 10-0-0 oc and fastened to each Strongloacks to be attached to walls at their outer ends or restrained by other mean 4) Gap between inside of top chord bearing and first diagonal or vertical web shall not 5) CAUTION, Do not erect truss backwards. with 3-10d (0.131 " X 3") nails. !d 0.500in. Walter P. Finn.PE No.22839 MiTek USA, Inc. FL Cart 6634 69114 Parke East Blvd. Tampa Fl. 33810 Date:. November 12,2018 WARNING- Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEKREFERANCE PAGE MX7473 rev. la/=015 BEFORE USE. Design valid for use only with VIITek0 connectors. This design Is based only upon parameters sho�n, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly Incorporate this design Into the overall building design. Bracing Indicated Is to prevent buckling of Individual truss web and/or chord members only. Additional temporary and permanent bracing MiTek' Is always required for stability and to prevent collapse with possible personal Injury and property damage. For general guidance regarding the fabrication, storage, delivery, erecfion and bracing of trusses and truss systems, seeANSVFPII Qu6ilty Criteria, DS13-69 and BCSI Building Component 6904 Parke East Blvd. Safety [niformationovallable from Truss Plate Institute, 218 N. Lee Street, Suite 312; Alexandria, VA 22314. Tampa, FL 33610 Job Truss Truss Type Qty 'Ply ACQUAVISTA T15560578 75575 FLF Floor, 11 1 Job Reference (optional) Chambers Truss, Inc., Fort Pierce, FL 0-3-8 " i 2-6-0 5x6 11 3x4 1 2 k7l c c C, 16 2X3 11 2x3 11 3 15 4xB � 7-2-8 6-11-0 H� 8.1JU s mar 11 2ulb Mi I eK Industries, Inc. mon,NOV 12 UU:3d:bZ ZUItJ I -age 1 ID:aNkrWfLwRDXTOZhc4Bay—yKyKq-BcFabMud5CVj7hKHbyne6BJegcbwEOBCikjaiSyJz7n 1-8-0 2-0-0 1-8-0 "3- ca 1:28.5 3x4 2X3 4 5 14 3X4 2X3 11 6 13 3x4 3x4 2x3 11 3x4 = 5x6 11 7 a 9 10 12 11 4x8 2X3 11 1 9 99 LOADING (psf) SPACING- 2-0-0 CSI. DEFL. in (loc) I/defl Ud PLATES GRIP TCLL 40.0 Plate Grip DOL 1.00 TC 0.39 Vert(LL) -0.14 14-15 >999 480 MT20 244/190 TCDL 20.0 Lumber DOL 1.00 BC 0.47 Vert(CT) -0.19 14-15 >999 360 BCLL 0.0 Rep Stress Incr YES WB 0.73 Horz(CT) -0.03 10 n/a n1a BCDL 5.0 Code FBC2017ITP12014 Matrix-S Weight: 94 lb FT = 20%F, 11 %E LUMBER- BRACING - TOP CHORD 2x4 SP M 30(flat) TOPCHORD Structural wood sheathing directly applied or 6-0-0 oc purlins, BOTCHORD 2x4 SP M 30(flat) except end verticals. WEBS 2x4 SP No.3(flat) BOTCHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS. (lb/size) 1=1037/0-3-0, 10=1037/0-3-0 FORCES. (lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOPCHORD 1-3=-1259/0,3-4=-1254/0,4-5---2189/0,5-6=-2189/0,6-7=-2189/O i-8=-1254/0,8-10=-'1259/0 BOTCHORD 14-15=0/1 954,13-14=0/2189,12-13=0/1 954 1 WEBS 5-14=-306/0, 6-13=-306/0, 1-15=0/1 524, 3-15=-314/0, 4-15=-867/0, 1-14=0/538,10-12=0/1 524, 8-12=-314/0, 7-12=-867/0, 7-13=0/538 NOTES- 1) Unbalanced floor live loads have been considered for this design. 2) Recommend 2x6 strongbacks, on edge, spaced at 10-0-0 oc and fastened to each I truss with 3-1 Od (0. 131 3") nails. Strongbacks to be attached to walls at their outer ends or restrained by other means. 3) Gap between inside of top chord bearing and first diagonal or vertical web shall not.6xceed 0.500in. Walter P. Finn PE No.22839 MiTek USA, Inc. FL Carl 6634 6904 Parke East Blvd. Tampa FL 33610 Oats: November 12,2018 WARNING- Verity design parameters and RE4D NOTES ON THIS AND INCLUDED MrTEK REFERANC EPA GE 11411-7473 rev. 1010312016 BEFORE USE. Design valid for use only with IVIffe1<8 connectors. This design is based only upon parameters shown, and Is for on Individual building component, not a truss system. Before use, the building designer must verity the applicability of design parameters'and properly Incorporate this design Into the overall building design. Bracing indicated Is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing MiTek' Is always required for stability and to prevent collapse with possible personal Injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, s9eANSVIFII Quality CrIllodo, DSB49 and BCSI BuRdIng Component 6904 Parke East Blvd. Safety [nformationovallable from Truss Plate Institute, 218 N. Lee Street, Suite 312-Nexondria, VA 2 1 2314. Tampa, FIL 33610 Job Truss Truss Type Qty I Ply ACQUAVITA T15560579 75575 FILG Floor 6 1 Job Reference (optional) Chambers I russ, Inc., t-ort Pierce, FL u.i;jus mar ii zuib mi ieK mausmes, Inc. mon NOV 12 UU:Jb:b3 ZU1b rage i ID:aNkrWfLwRDXTOZhc4Bay—yKyKq-copypivFsWdairuT9f[tf0sqPOwPzTjLxDT7EUYJz7m 0-3-S 2-6-0 1-4-10 2-0-0 1-6-10 Scale 1:27.0 5x6 11 3x4 2x3 11 3x4 2x3 11 3x4 2X3 11 3x4 3x4 1 2 a 4 5 6 7 8 9 0 q 6 15 14 13 12 11 10 2x3 11 4x8 3x4 2X3 3x6 3x6 6-11-2 B-0-10 16-1-3 6-7-10 71&; 10 L;1 140-0 � 1 0 7-0-10 Plate Offsets (X,Y)-- [1:0-3-gEdqel,[5:0-1-8,Edqel,[6:0-1-8,Edqel,[12:0-1-8,Edqel,l[13:0-1-8,Edge1 LOADING (psf) SPACING- 2-0-0 CS1. DEFL. in (loc) I/defl Ud PLATES GRIP TCLL 40.0 Plate Grip DOL 1.00 TC 0.36 Vert(LL) -0.11 13-14 >999 480 MT20 244/190 TCDL 20.0 Lumber DOL 1.00 BC 0.52 VerI(CT) -0.16 13-14 >999 360 BCLL 0.0 Rep Stress Incr YES WB 0.71 Horz(CT) 0.02 10 n/a n/a BCDL 5.0 Code FBC2017/TP[2014 Matrix-S Weight: 93 lb FT = 20%F, I 1%E LUIMBER- BRACING- TOPCHORD 2x4 SP M 30(flat) TOPCHORD Structural wood sheathing directly applied or 6-0-0 oc purlins, BOTCHORD 2x4 SP M 30(flat) except end verticals. WEBS 2x4 SP N.o.3(flat) BOTCHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS. (lb/size) 10=1015/Mechanical, 1=1015/0-3-0 FORCES. (lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when sho TOPCHORD 1-3=-1228/0, 3-4=-1223/6,4-5=-2092/0,5-6=-2092/0,6-7=-1909/0, 8=-1909/0 BOTCHORD 13-14=0/1 894, 12-13=0/2092,11-12=0/2092, 10-11 =0/1 218 WEBS 5-13=-299/0,1-14=0/1486,3-14=-317/0, 4�114=-833/0, 4-13=0/512,8 1 0=-1 497/0, 8-11 =0/856, 7-11 =-296/0, 6-11 =-495/0 NOTES- 1 ) Unbalanced floor live loads have been considered for this design. 2) Refer to girder(s) for truss to truss connections. 3) Recommend 2x6 strongbacks, on edge, spaced at 10-0-0 oc and fastened to each �russ with 3-10d (0.131" X 3") nails. Strongbacks to be attached to walls at their outer ends or restrained by other means. 4) Gap between inside of top chord bearing and first diagonal or vertical web shall not xceed 0.500in. 5) CAUTION, Do not erect truss backwards. Walter P. Finn PE No.22839 MiTek USA, Inc. FL Cart 663,4 69D4 Parke East Blvd. Tampa FL 33610 Date: November 12,2018 ,& WARNING - Verify design parameters and READ NOTES ON -THIS AND INCLUDED MrTEK REFERANC E PAGE mu-7473 rev. 1011=015 BEFORE USE. Design valid for use only with MITek@ connectors, This design Is based only upon parameters shown, and is for an Individual building component, not a truss system. Before use, the building designer must Verify the applicability of design parameters and properly Incorporate this design into the overall building design. Bracing Indicated Is to prevent buckling of Individual truss web and/or chord mdmbers only. Additional temporary and permanent bracing MOW Is always required for stability and to prevent collapse with possible personal Injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, seeANSVrPI1 Quality CrIll DSB-69 and BCSI Bulldlng Component 6904 Parke East Blvd. Safety Informationavallable from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 212314. Tampa, Fl- 33610 Job Truss Truss Type Cty I Ply ACQUAVISTA T15560580 75575 FLH Floor 21 1 I Job Reference (optional) unamDers I russ, Inc., i--ort merce, I-L 0-3-8 2-6-0 5X6 3x4 2 C C� 16 2x3 11 2X3 3 15 4x8 6-3-8 4X4 = 2X3 4 5 14 4X4 ts.iiju s mar ii ZUItS Ml I BK inausines, Inc. mon r4ov iz uu:jt5:oq zuio rage i ID:aNkrWfLwRD)CrOZhc4Bay—yKyKq-4—NK02wtdp]RN?TgiNp6BcPOIPIDiyCVA2CgnKyJz7I 2-0-0 2 - "at = 1;25.3 8-5-0 2x3 11 4X4 6 7 13 4X4 2X3 3x4 = 5X6 11 8 9 10 12 11 4x8 2X3 11 0 96 C� 6-3-6 6-0-0 ojiiB 1-010 1 1-0-C) 0-11118 6-0-0 Plate Offsets (X,Y)-- rl:0-3-0, Edge], r5:0-1 -8, Edge], [6:0-1-8,0-0-01, rl 0:0-3-0, Edge], I rl 1:0-1 -8, Edge], rl 3:0-1-8, Edge],[ 14:0-1 -8, Edgel q LOADING (pso SPACING- 2-0-0 CSI. DEFL. in (loc) I/defl Ud PLATES GRIP TCLL 40.0 Plate Grip DOL 1.00 TC: 0.32 Vert(LL) -0.08 14-15 >999 480 MT20 244/190 TCDL 20.0 Lumber.DOL 1.00 BC 0.35 Verl(CT) -0.11 14-15 >999 360 BCLL 0.0 Rep Stress Incr YES WB 0.63 Horz(CT) -0.02 10 n/a n/a BCDL 5.0 Code FBC2017fTP12014 Matrix-S Weight: 87 lb FT = 20%F, I I%E LUMBER- BRACING- TOPCHORD 2x4 SP M 30(flat) TOPCHORD Structural wood sheathing directly applied or 6-0-0 oc purlins, BOTCHORD 2x4 SP M 30(flat) except end verticals. ' WEBS 2x4 SP No.3(flat) BOTCHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS. (lb/size) 1=918/0-3-0, 10=918/0-3-0. FORCES. (lb) -Max. Comp./Max. Ten. -All forces 250 (lb) or less except when sho" TOPCHORD 1-3=-1092/0, 3-4=-1087/0, 4-5=-1708/0,5-6=-1708/0,6-7=-1708/0, _T BOTCHORD 14-15=0/1628; 13-14=0/1708,12-13=0/1628 �8=-1087/0, 8-10=-1092/0 WEBS 5-14=-338/10,6-13=-338/10,1-15=0/1321, 3-15=-321/0, 4-15=-670/C, 4-14=-32/446,10-12=0/1321, 8-12=-321/0, 7-12=-670/0, 7-13=-32/446 NOTES- 1) Unbalanced floor live loads have been considered for this design. 2) Recommend 2x6 strongbacks, on edge, spaced at 10-0-0 oc and fastened to each truss with 3-1 Od (0.131" X 3") nails. Strongbacks to be attached to walls at their outer ends or restrained by other means'. 3) Gap between inside of top chord bearing and first diagonal or vertical web shall not 'exceed 0.500in. Walter P. Finn. PE No.12839 MiTak USA, Inc. Fl. Cart 6634 6904 Parke East Blvd. Tampa Fl. 33610 Date:' November 12,2018 WARNING- Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERANCE PAGE 111111-7473 mv. 1010312015 BEFORE USE. Design valid for use only with MIT08 connectors. This design is based only upon parameters show , n, and Is for an individual building component, not a truss system. Before use, the building designer must verity the applicability of design parametersland properly incorporate this design Into the overall MF building design. Bracing Indicated Is to prevent buckling of Individual truss web andlor chord members only. Additional temporary and permanent bracing MiTek' Is always required for stability and to prevent collapse with possible personal Injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, seeANSI/Tpll Quality Crillarks, DSB-89 and BCSI Bulding Componant 6904 Parke East Blvd. Safety [nformatlanovallable from Truss Plate Institute, 218 N. Lee Street, Suite 312; Alexandria, VA 22314. Tampa, FIL 33610 Job Truss Truss Type Qty Ply ACQUAVISTA T15560581 75575 FLI Floor 1 Job Reference (optional) Chambers I russ, Inc., Fort Pierce, FL 0. IOU b NMI 1 1 4V10 IVII I �K 11MUSMUS, 1171U. IVIU11I INOV 14 09:36:54 401 a rags I ID:aNkrWfLwRDXTOZhc4Bay—yKyKq-4—NK02wtdpIRN?TgjNp6BcP1 DPIAizkVA2CgnKyJz7l 0-3-8 2-6-0 2-4-0 2-0-0 2-4-0 i i i I S pale = 1:22.1 4X6 11 3x4 2x3 11 3X4 — 2X3 11 3x4 4X6 11 1 2 3 4 5 3x4 6 7 8 9 q CP Vr r 14 2X3 11 13 3xB 12 2X3 11 2X3 11 10 3xB 12-8-8 9 2X3 Plate Offsets (X,Y)-- 1:0-3-0, Edgel, [4:0-1 -8, Edgel, r5:0-1-8, Edgell [8:0-3-0, Edge], [9:0-1-8, Edgel, [ 11:0- 1 -8,0-0-01, [12:0-1-8, Edgel LOADING (psf) SPACING- 2-0-0 CS1. DEFL. in (loc) I/defl Ud PLATES GRIP TCLL 40.0 Plate Grip DOL 1.00 TC; 0.22 Vert(LL) -0.08 10-11 >999 480 MT20 244/190 TCDL 20.0 Lumber DOL 1.00 BC :0.36 Verl(CT) -0.09 10-11 >999 360 BCLL 0.0 Rep Stress Incr YES WB 0.53 Horz(CT) -0.01 8 n/a n/a BCDL 5.0 Code FBC2017ITP12014 Matrix-S Weight: 75 lb FT = 20%F, 11 %E LIUMBER- BRACING- TOPCHORD 2x4 SP M 30(flat) TOPCHORD Structural wood sheathing directly applied or 6-0-0 oc purlins, BOTCHORD 2x4 SP M 30(flat) except end verticals. WEBS 2x4 SP No.3(flat) BOTCHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS. (lb/size) 1=799/0-3-0, 8=799/0-3-0 FORCES. (lb) -Max. Comp./Max. Ten. -All forces 250 (lb) or less.except when shown. TOPCHORD 1-3=-922/0, 3-4=-917/0, 4-5=-1296/0, 5-6=-917/0, 6-8=-922/0 BOTCHORD 12-13=0/1 296, 11-12=0/1 296, 10-11 =0/1 296 1 WEBS 1- 1 3=0/1 114, 3-13=-346/0, 4-13=-558/0, 8-1 0=0/i 114, 6-1 0=-346/0, 5-1 0=-558/0 NOTES- 1) Unbalanced floor live loads have been considered for this design. 2) Recommend 2x6 strongbacks, on edge, spaced at 10-0-0 oc and fastened to each truss with 3-10d (0.131 " X 3") nails. Strongbacks to be attached to walls at their outer ends or restrained by other means I . 3) Gap between inside of top chord bearing and first diagonal or vertical web shall not el xceed 0.500in. Walter P. Finn.PE No.22839 MiTek USA, Inc. FL Cert 6634 691114 Parke East Blvd. Tampa FL 33610 Date: November 12,2018 WARNING- Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERANCE PAGE M11-7473 rev. 1WO312015 BEFORE USE. Design valid for use only with Mffek@ connectors. This design Is based only upon parameters shown, and Is for an Individual building component, not a truss system. Before use, the building designer must verify the appllcoblllty of design parometers'and properly Incorporate this design Into the overall building design. Bracing Indicated Is to prevent buckling of Individual truss web and/or chord members only. Additional temporary and permanent bracing Is always required for stability and to prevent collapse with possible personal Injury and property domage. For general guidance regarding the MiTek* fabrication, storage, delivery, erection and bracing of trusses and truss systems, seeANSVTPII Quality Critarla. DSB-89 and BCSI BuldIng Camporant 6904 Parke East Blvd. Saferty [nformationavallable from Truss Plate Institute, 218 N. Lee Street Suite 312, Alexandria, VA 22314. Tampa, FL 33610 Job Truss Truss Type City Ply ACQUAVISTA T155605B2 75575 FLJ Floor 7 1 Job Reference -(optional) Lonamoers i russ, Inc., t-on vierce, t-L 0-3-8 1­� i 3X6 11 3x4 1 2 10 2x3 11 LOADING (psf) SPACING- 2-0-0 TCLL 40.0 Plate Grip DOL 1.00 TCDL 20.0 Lumber DOL 1.00 BCLL 0.0 Rep Stress Incr YES BCDL 5.0 Code FBC2017/TP12014 b.iju s mar i i ZURS Ml I eK inausines, inc..mon ivov ie uu:omon zujtj rage i ID:aNkrWfLwRDXTOZhc4Bay—yKyKq-ZB)dEOwVN7t[?92sH4KLkpxBopguRUoeOiyEJnyJz7k 2-0-0 Scale; 3/4"=l' 2x3 3x4 3x6 11 i 2X3 11 3 i 4 5 6 9 3x4 4-2-0 3x4 a 8-0-8 CS1. DEFL. in (loc) I/defl Lid TC 0 '0 Vert(LL) -0.04 7-8 >999 480 BC O�20 Vert(CT) -0.05 7-8 >999 360 WB - 0.29 Horz(CT) -0..00 6 n1a n/a Matrix-S LUMBER - TOP CHORD 2x4 SP M 30(flat) BOTCHORD 2x4SPM30(flat) WEBS 2x4 SP No.3(flat) REACTIONS. (lb/size) 1=496/0-3-0,6=496/0-3-0 FORCES. (lb) -Max. Comp./Max. Ten. -All forces 250 (lb) or less exceptw.hen shom TOPCHORD 1-3=-506/0, 3-4=-501/0, 4-6=-506/0 BOT CHORD 8-9=0/501 WEBS 3-9=-304/0, 4-8=-304/011-9=0/600, 6-8=0/600 NOTES- 1) Unbalanced floor live loads have been considered for this design. 2) Recommend 2x6 strongbacks, on edge, spaced at 10-0-0 oc and fastened to each Strongbacks to be attached to walls at their outer ends or restrained by other mean 3) Gap between inside of top chord bearing and first diagonal or vertical web shall not 7 2X3 11 PLATES GRIP MT20 244/190 Weight: 48 lb FT = 20%F, 1 I%E BRACING- TOPCHORD Structural wood sheathing directly applied or 6-0-0 oc purlins, except end verticals. BOTCHORD Rigid ceiling directly applied or 10-0-0 oc bracing. with 3-1 Od (0. 131 " X 3") nails. )d 0.500in. Walter P. Finn PE No.22839 MiTek USA, Inc. FIL Cart 6834 6904 Parke East Blvd. Tampa FL 33810 (Yale-.- . November 12,2018 WARNING- Verify design parameters and READ NOTES ON THIS AND iNcLuDED mrTEK REFERANC� PAGE 11111­7473,e�,. 1010312015 BEFORE USE. Design valid for use only with Vffek8 connectors. This design Is based only upon parameters shomh and Is for an Individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters , and properly Incorporate this design Into the overall building design. Bracing Indicated Is to prevent buckling of Individual truss web and/or chord members only. Additional temporary and permanent bracing MiTek' Is always required for stability and to prevent collapse with possible personal Injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, seeAN3VTP1I Quality Criteria, DSB-89 and BCSI Building Component Safety Informationavalloble from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314. 6904 Parke East Blvd. Tampa, FIL 33610 Job Truss Truss Type Qty Ply ACQUAVISTA, T15560583 75575 FLK Floor 2 Job Reference (optional) Chambers I russ, inc., Fori Pierce, FL 8.130 u rvikir 11 2018 IVII !UK inuusirieb, mu. rviun mv te- uu:omoo eujo rdgw i ID:aNkrWfLwRD)CrOZhc4Bay—yKyKq-ZB)dEOwVN7tl?92sH4KLkpxB1 pajRKzeOiyEJnyJz7k 2-6-0 2-4-14 2-0-0 2-2-14 Scale = 1:30.9 2x3 3X4 1 3X8 P.01 go US 2x3 11 3X4 2X3 11 2 3 4 5 14 13 12 3xS 2x3 11 3X4 . — .. � _ "10-0-6 1 7-10-14 Plate Offsets (X,Y)-- fl: Edge,0-1 -81, [4:0-1 -8, Edge], [9:0-1 -8, Edge], [10:0-1 -8, E LOADING (psf) SPACING- 2-0-0 CS1. TCLL 40.0 Plate Grip DOL 1.00 TC 0.28 TCDL 20.0 Lumber DOL 1.00 BC 0.59 BCLL 0.0 Rep Stress Incr YES WB 0.91 BCDL 5.0 Code FBC2017fTP12014 Matdx-S 3X4 2X3 11 3x4 = 6x8 6 7 a 9 DEFL. in (loc) I/defl Ud Vert(LL) -0.14 13 >999 480 Vert(CT) -0.22 13 >946 360 Horz(CT) 0.02 9 n/a n/a LUMEIER- BRACING - TOP CHORD 2x4 SP M 30(flat) TOPCHORD BOT CHORD 2x4 SP No.3(flat) *Except* 10-15: 2x4 SP M 30(flat) BOTCHORD WEBS 2x4 SP No.3(flat) REACTIONS. (lb/size) 9=1127/0-3-0,16=1127/Mechanical FORCES. (lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOPCHORD 2-3=-2708/0, 3-4=-2708/0, 4-5=-3148/0,5-6=-3148/0, 6-7=-1673/0, 7i[9=-1678/0 BOTCHORD 14-15=0/1666,13-14=0/3148,12-13=0/3148,11-12=0/26B3,15-16=-�127/0 WEBS 5-12=-261/0, 2-15=- 1932/0, 2-14=0/1 216, 3-14=-302/0, 4-14=-516/0, 9-11 =0/1 920, 7-11 =-294/0, 6-11 �- 1179/0, 6 -12=0/560 1 11 10 4x10 2X3 11 3 PLATES GRIP MT20 244/190 9 9 T Weight: 96 lb FT = 20%F, 1.1 %E Structural wood sheathing directly applied or 6-0-0 oc purlins, except end verticals. Rigid ceiling directly applied or 10-0-0 oc bracing, Except: 6-0-0 oc bracing: 15-16. NOTES- 1) Refer to girder(s) for truss to truss connections. 2) Recommend 2x6 strongbacks, on edge, spaced at 10-0-0 oc and fastened to each russ with 3-1 Od (0.131 " X 3") nails. Strongbacks to be attached to walls at their outer ends or restrained by other meanJ1. 3) Gap between inside of top chord bearing and first diagonal or vertical web shall not el xceed 0.500in. 4) CAUTION, Do not erect truss backwards. I Walter P. Finn. PE No.22839 MiTak USA, Inc. FL Cart 6634 6904 Parke East Blvd. Tampa Fl. 33610 DaW November 12,2018 WARNING- Verify design parameters and READ NOTES ON THIS AND XCLUDED MITE)CREFERANCE PAGE M11-7473 rev. 10/0=015 BEFORE USE. Design valid for use onlywith MITek8 connectors. This design Is based only upon parameters shown, and Is for an Individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters;'and properly Incorporate this design Into the overall building design. Bracing Indicated Is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing MiTek* Is always required for stability and to prevent collapse with possible personal Injury and property damage. For general guidance regarding the fabrication. storage, delivery, erection and bracing of trusses and truss systems, seeANSI/711111 Quo"T, Criteria, DSO-89 and 1i BuDdIng Cantipariont 6904 Parke East Blvd. Safety ffiforrinationavallable from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22 4. Tampa, Fl- 33610 Job Truss Truss Type City Ply ACQUAVISTA T15560584 75575 FLL Floor 8 Job Reference (optional) Chambers Truss, Inc., Fort Pierce, FL 8.130s Mar il 2018 Will UK 1[1UU5ir1U5, 1HU. IVIUI I INUV 14 VV:00:QU 4U10 rage 1 ID:aNkrWfLwRD)CrOZhc4Bay—yKyKq-1 NV5Rkx78R?9cld2qosaGi UJXDwUAosndMhnrDyJz7j 0-3-8 2-6-0 1-9-2 2-0-0 2-2-14 guale 1:29.7 6xB 3x4 2x3 11 3x4 2x3 2x3 11 3x4 2x3 11 3x4 6x8 1 2 3 4 5 6 7 8 9 10 L_ Oi 9 -------- 9 9 C9 T 16 15 14 13 12 11 2X3 11 4x10 3X4 3x4 4x10 2X3 11 7-3-10 lopill 2NNOV1.,-80 17-0-8 1 MR 7-0-2 71-�01 7-5-14 f.4 Plate Offsets (X,Y)-- [1:0-1 -8,Edgel, [5:0-1-8, Edge], [6:0-1 -8,0-0-01, [10:0-1 -8, Edge], t 11:0-1 -8, Edclel, [13:0-1-8, Edgel, [14:0-1-8, Edge] LOADING (psf) SPACING- 2-0-0 CS1. DEFL. in (loc) I/def] Ud PLATES GRIP TCLL 40.0 Plate Grip DOL 1.00 TC 0.49 Vert(LL) -0.20 12-13 >977 480 MT20 244/190 TCDL 20.0 Lumber DOL. 1.00 BC 0.62 Vert(CT) -0.30 12-13 >657 360 BCLL 0.0 Rep Stress Incr YES WB 0.87 Horz(CT) -0.04 10 n/a n1a BCDL 5.0 Code FBC2017[TP]2014 Matdx-S Weight: 92 lb FT 20%F, I I %E LUMBER - TOP CHORD 2x4 SP M 30(flat) BOT CHORD 2x4 SP M 30(flat) WEBS 2x4 SP No.3(flat) REACTIONS. (lb/size) 1=1081/0-3-0, 10=1081/0-3-0 FORCES. (lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when show TOPCHORD 1-3=-1599/0, 3-4=-1594/0, 4-5=-2892/0, 5-6=-2892/0, 6-7=-2892/0, 7 BOT CHORD 14-15=0/2522, 13-14=0/2892, 12-13=0/2527 WEBS 5-14=-337/0, 6-13=-279/0, 1 -1 6=0/1 829, 3-15=-305/0, 4-15=-1 084/0, 7-12=-1084/0, 7-13=0/655 BRACING- TOPCHORD , Structural wood sheathing directly applied or 6-0-0 oc puflins, except end verticals. BOTCHORD Rigid ceiling directly applied or 10-0-0 oc bracing. -1598/0, 8-1 0=- 1603/0 4=0/690,10-12=0/1834, 8-12=-292/0, NOTES- 1) Unbalanced floor live loads have been considered for this design. 2) Recommend 2x6 strongbacks, on edge, spaced at 10-.0-0 oc and fastened to each truss with 3-1 Od (0.131 " X 3") nails. Strongbacks to be attached to walls at their outer ends or restrained by other meansl I 3) Gap between inside of top chord bearing and first diagonal or vertical web shall not exceed 0.500in. Walter P. Finn PE No.22839 MiTek USA, Inc. Fl. Cart 6634 6904 Parke East Slvd. Tampa FL 33610 Date: November 12,2018 AWARNING -Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEKREFERANCE PAGE MX7473 rev. 1010&2015 BEFORE USE. Design valid for use only with MfTekO connectors. This design Is based only upon parameters showr�, and Is for an Individual building component not a truss system. Before use, the building designer must verify the applicability of design parameters bnd properly Incorporate this design Into the overall building design. Bracing Indicated Is to prevent buckling of Individual truss web and/or chord members only. Additional temporary and permanent bracing MiTek' Is always required for stability and to prevent collapse with possible personal Injury and property d6mage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, seeANSVrpll Quat"T, Criteria. DSB-89 and BCSI Bullding Component 6904 Parke East Blvd. Safety triformationavollable from Truss Plate Institute, 218 N. Leg Street, Suite 312, AJexandrla, VA 22 4. Tampa, FL 33610 Job Truss Truss Type Qty Ply ACQUAVISTA. . T155605135 75575 FUM Floor 2 1 Job Reference (optional) unamDers i russ, Inc., i--on vierce, ti.-i ou s mar i i zui?j mi i eK inausines, inc. man piov iz utvoomt zu i o rage i ID:aNkrWfLwRDXTOZhc4Bay—yKyKq-VZ3Tf4ylvk7OESCFOVNppElYPdJMvJFXSORLNfyJz7i 0-3-8 2-6-0 2-4-0 2-0-0 2-4-0 S&a Pe-- 1:22.1 5X6 [I 3x4 2X3 11 1 2 3 e 14 2X3 11 13 3x8 5-6-0 3x4 4 12 2X3 11 5 3x4 — 11 2X3 2X3 6 10 3x8 3X4 5X6 11 7 8 9 2X3 LOADING (psf]l SPACING- 2-0-0 CS1. DEFL. in (loc) Vdef] Ud PLATES GRIP TCLL 40.0 Plate Grip DOL 1.00 TC; 0.23 Vert(LL) -0.08 12-13 >999 480 MT20 244/190 TCDL 20.0 Lumber DOL 1.00 BC 0.39 Vert(CT) -0.11 12-13 >999 360 BCLL 0.0 Rep Stress Incr YES WB 0.61 Horz(CT) -0.01 8 n/a n/a BCDL 5.0 Code FBC2017/TP[2014 Matrix-S Weight: 71 lb FT = 20%F, I I%E LUMBER- BRACING - TOP CHORD 2x4 SP M 30(flat) TOPCHORD BOT CHORD 2x4 SP M 30(flat) WEBS 2x4 SP No.3(flat) BOTCHORD REACTIONS. (lb/size) 1=799/0-3-0,8=799/0-3-0 FORCES. (lb) -Max. Comp./Max. Ten. -All forces 250 (lb) or less except when show TOPCHORD 1-3=-1 118/0, 3-4=-1 13/0, 4-6=ml 576/0, 5-6=-1 113/0, 6-8=-1 118/0 BOTCHORD 12-13=0/1 576, 11-12--0/1576, 10-11 =0/11 576 WEBS 1-1 3=0/1 277, 3-13=-340/0, 4-13=-638/0, B-1 0=011 277, 6-1 0=-340/0, 5-1 0=-638/0 NOTES- 1) Unbalanced floor live loads have been considered for this design. Structural wood sheathing directly applied or 6-0-0 oc pudins, except end verticals. Rigid ceiling directly applied or 10-0-0 oc bracing. 2) Recommend 2x6 strongbacks, on edge, spaced at. 10-0-0 oc and fastened to each russ with 3-1 Od (0.131 " X 3") nails. Strongbacks to be attached to walls at their outer ends or restrained by other meansi. 3) Gap between inside of top chord bearing and first diagonal or vertical web shall not exceed 0.500in. Walter P. Finn,PE No.22839 MiTek USA, Inc. FL Cart 6634 6904 Parke East Blvd. Tampa FL 33610 Date� . November 12,2018 A WARNING -Verity design parameters and READ NOTES ON THIS AND INCLUDED MITEKREFERANCE PAGE MIP7473 re. M=015 BEFORE USE. Design valid for use only with M71ek& connectors. This design Is based only upon parameters showk and Is for an Individual building component not a truss system. Before use, the, building designer must verity the applicability of design parometers'and properly Incorporate this design Into the overall building design. Bracing Indicated Is to prevent buckling of Individual truss web and/or chord members only. Additional temporary and permanent bracing MiTek' Is always required for stability and to prevent collapse with possible personal Injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, seeANSVWII Quality Citte'ria. DSB-69 and BCSI Building Component 6904 Parke East Blvd. Safety Inforimationovallable from Truss Plate Institute, 218 N. Lee Street Suite 312, AJexandrio, VA 22314. Tampa, FIL 33610 Job Truss Truss Type Oty Ply ACQUAVII TA T15560586 75575 GEE MONOPITCH SUPPORTED 2 1 Job Reference (optional) Lonamiaers iruss, inc., �-orl: rierce, �-L F1 2 miou s mar i i zuic; mi i eK inausines, inc. man iNiov ie uto;jo;oo eu io rage i ID:aNkrWfLwRDXTOZhc4Bay—yKyKq-zmcrsQzOg2FtscnRyDu2MSZhHllDev?45gAuw6yJz7h 2-8-0 9-FI-n 3 4x6 = Scale = 1:10.6 I I LOADING (pst) SPACING- 2-0-0 CSI. DEFL. in (loc) I/def] Ud PLATES GRIP TCLL 20.0 Plate Grip DOL 1.25 TC 0.35 Vert(LL) 0.01 1 n/r 120 MT20 244/190 TCDL 15.0 Lumber DOL 1.25 BC 0.03 Vert(CT) -0.00 1 n/r 120 BCLL 0.0 Rep Stress Incr YES WEI 0.00 Horz(CT) 0.00 4 n/a n/a BCDL 10.0 Code FBC2017/TP12014 Matrix-P Weight: 12 lb FT = 20% LIUMBER- TOPCHORD 2X4 SP M 30 BOTCHORD 2X4 SP M 30 WEBS 2x4 SP No.3 OTHERS 2x4 SP No.3 REACTIONS. (lb/size) 4=76/2-8-0,2"240/2-8-0 Max Horz 2=174(LC 12) Max Uplift 4=-53(LC 9), 2=-331 (LC 12) Max G rev 4=91 (LC 17), 2=240(LC 1) FORCES. (lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when NOTES- 1) Wind: ASCE 7710; Vult=170mph (3-second gust) Vasd=132mph; TCDL=4.2psf; B 11; Exp D; Encl., GCpi=0.18; MWFRS (directional) and C-C Comer(3) zone; porch & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 2) Truss designed for wind loads in the plane of the truss only. For studs exposed to Gable End Details as applicable, or consult qualified building designer as per ANS 3) Gable requires'continuous bottom chord bearing. 4) Gable studs spaced at 2-0-0 oc. 5) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent 6) * This truss has been designed for a live load of 20.Opsf on the bottom chord in all will fit between the bottom chord and any other members. 7) Provide mechanical connection (by others) of truss to bearing plate capable of witl 2=331. BRACING - TOP CHORD Structural wood sheathing directly applied or 2-8-0 oc purlins, except end verticals. BOTCHORD Rigid ceiling directly applied or 6-0-0 oc bracing. L=3.Opsf; h=33ft;.B=53ft; L=65ft; eave=2ft; Cat. and right exposed;C�C for members and forces id (normal to the face), see Standard Industry 311. any other live loads. is where a rectangle 3-6-0 tall by 2-0-0 wide iding 100 lb uplift at joint(s) 4 except at=lb) Walter P. Finn PE No.22839, M!Tek USA, Inic. FL Car( 6634 6904 Parke East Blvd. Tampa FL 33610 Date: November 12,2018 ,& WARNING - Verify design parameters and READ NOTES ON THIS AND iNcLuDED mr;EKR'EFERANCE1 PAGEM11-7473 rev. 10(03/2015 BEFORE USE. Design valid for use only with Mrre& connectors. This design Is based only upon parameters shown', and Is for an Individual building component not a truss system. Before use, the building designer must verify the applicability of design parameters 6nd properly Incorporate this design Into the overall building design. Bracing indicated Is to prevent buckling of Individual truss web and/or chord marpbers only. Additional temporary and permanent bracing MiTek' Is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regardIng the , . fabrication, storage, delivery, erection and bracing of trusses and truss systems. seeANSVTPII Qual Critefla, DSB-89 and IBM Building Component. 6904 Parke East Blvd. Safety Informationovallable from Truss Plate Institute, 218 N. Lee Street Suite 312, Alexandria, VA 22114. Tampa, FIL 33610 Job Tru s Truss Type Q ty ply �.ACQUAVISTA T15560587 75575 GFZ FLOOR 1 2 �nal) L;namners truss, Inc., t-ort merce, I-I_ 3-1-14 u.-Iou s mar i i ZU1 1:1 M1 I eK inausines, inc. mon Nov i z uv:otj:ou zui b rage i ID:aNkrWfLwRDXTOZhc4Bay—yKyKq-RyAD3m—ORMNkTmMdWwPHuf6mhQxhN7uEJKwRSYyJz7g Scale = 1:20.4 THD46 THD46 3X4 11 3xB 5x12 1 5x12 11 2 3X8 3 4 5 F __1 L-A I I __T1_1 i [i fi n I I tLu THD46 10x10 10 12 9 13 14 8 15 16 17 7 18 19 6 5x6 THD46 1ox10 THD46 HUS46 7xl 4 = HUS46 THD46 HUS46 THD46 HUS46 5x6 THD46 3-1-14 6-2-0 9-2-2 12-4-0 3-1-14 3-0-2 3-0-2 3-1-14 Plate Offsets (X,Y)-- [2:0 -3-8,0-1-81, 14:0-3-8,0-1.81, r6:Edge,0-2-81, [7:0-3-8,0-5-01, r8:0-7-0,0-4-121, [9:0-3-8,0-5-01 LOADING (psf) SPACING- 2-0-0 CS1. DEFL. in (loc) Vdef] Ud PLATES GRIP TCLL 40.0 Plate Grip DOL 1.00 TC 0.75 Vert(LL) -0.13 8 >999 480 MT20 244/190 TCDL 20 * 0 Lumber DOL 1.00 BC 0.65 Vert(CT) -0.22 8 >662 360 BCLL 0.0 Rep Stress Incr NO WB 0.98 Horz(CT) 0.02 6 n/a n/a BCDL 5.0 Code FBC2017/TP12014 Matrix -MS Weight: 169 lb FT = 20% LUMBER- BRACING - TOP CHORD 2x6 SP No.2 TOPCHORD Structural wood sheathing directly applied or 3-2-6 oc purlins, BOTCHORD 2X6 SP 240OF 2.OE except end verticals. WEBS 2x4 SP No.3 *Except* BOTCHORD Rigid ceiling directly applied or 10-0-0 oc bracing. 1-10,5-6:2x6 SP No.2,1-9,5-7: 2x4 SP M 30 REACTIONS. (lb/size) 10=7067/Mechanical, 6=6828/Mechanical FORCES. (lb) - Max. Comp./Max. Ten. - Ali forces 250 (lb) or less except when showq. TOPCHORD 1-10=-6213/0,1-2=-10330/0, 2-3=-13476/0, 3-4=-13476/0, 4-5=-10295/0, 5-6=-5484/0 BOTCHORD 9-10=W747, 8-9=0/10330, 7-8=0/10295, 6-7=0/700 1 WEBS 1-9=0/10831, 2-9=-3087/0, 2-8=0/3534, 4-8=0/3574, 4-7=-1772/0, 5-7i=0/10846 NOTES - I ) 2-ply truss to be connected together with 1 Od (0. 131 "x3") nails as follows: Top chords connected as follows: 2x6 - 2 rows staggered at 0-9-0 oc. Bottom chords connected as follows: 2x6 - 2 rows staggered at 0-9-0 oc. Webs connected as follows: 2x4 - 1 row at 0-9-0 oc, Except member 2-9 2x4 - 2 rowl staggered at 0-2-0 oc, member 4-7 2x4 - 2 rows staggered at 0-2-0 oc. 2) All loads are considered equally applied to all plies, except if noted as front (F) or bac k (B) face in the LOAD CASE(S) section. Ply to ply connections have been provided to distribute only loads noted as (F) or (B), unles I s otherwise indicated. 3) Refer to girder(s) for truss to truss connections. 1 4) Recommend 2x6 strongbacks, on edge, spaced at 10-0-0 oc and fastened to each truss with 3-10d (0.131- X 3") nails. Strongbacks to be attached to walls at their outer ends or restrained by other means.1 5) Use USP THD46 (With 16d nails into Girder& 10d nails into Truss) or equivalent spaced at 1-10-4 oc max. starting at 1-0-12 from the left end to 2-11-0 to connect truss(es) to front face of top chord. 6) Use USP THD46 (With 16d nails into Girder& 10d nails into Truss) or equivalent spaced at 2-0-0 oc max. starling at 4-7-8 from the left end to 10-5-12 to connect truss(es) to front face of bottom chord. 7) Use USP THD46 (With 16d nails into Girder & 10d nails into Truss) or equivalent spaced at 2-0-0 oc, max. starting at 1-4-8 from the left end to 3-4-8 to connect truss(es) to back face of bottom chord. 1 8) Use USP HUS46 (With 16d nails into Girder & 16d nails into Truss) or equivalent spaced at 2-0-0 oc max. starting at 5-4-8 from the left end to 11 -2-12 to connect truss(es) to back face of bottom chord. 9) Fill all nail holes where hanger is in contact with lumber. LOAD CASE(S) Standard 1) Dead + Floor Live (balanced): Lumber Increase=1.00, Plate Increase=1.00 Uniform Loads (plf) Vert: 1-5=-120, 6-10=-10 Walter P. Finn PE No.22839 MiTek USA, Inc. FL Cert 6634 6904 Parke East Blvd. Tampa FL 33610 Date: November 12,2018 ,& WARNING - Verify design parameters andRE4D NOTES ON THISAND INCLUDED MITEKREFERANCE PAGE MIP7473 rev. la(0312015 BEFORE USE. Design valid for use only with MITek@ connectors. This design Is based only upon parameters shown', and Is for an Individual bulldind component, not a truss system. Before use, the building designer must verify the applicability of design parameters 6nd properly Incorporate this design Into the overall building design. Bracing Indicated Is to prevent buckling of Individual truss web and/or chord mernbers only. Additional temporary and permanent bracing MiTek' Is always required for stability and to prevent collapse with possible personal Injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, seeANSVrPlI Quality CrIlliefla, DSIII-89 and BCSI Building Component 6904 Parke East Blvd. Safety Informationovallable from Truss Plate Institute, 218 N. Lee Street, Suite 312. Alexandria, VA 22314. Tampa, FL 33610 Job Truss Truss Type Qty- Ply ACQUAVISTA T15560587 75575 GFZ FLOOR 1 2 Job Reference (optional) Chambers Truss, Inc., Fort Pierce, FL LOAD CASE(S) Standard Concentrated Loads (lb) Vert: 9=-1 005(B) 2=-1 007(F) 7=-1 005(B) 11 =-1 01 7(F) 112=-1 005(B) 13=-1 8.130 s Mar 11 2018 MiTek Industries, Inc. Mon Nov 12 09:38:59 2018 Page 2 ID:aNkrWfLwRDXTOZhc4Bay—yKyKq-RyAD3m—ORMNkTmMdWwPHuf6mhQxhN7uEJKwRSYyJz7g 14=-1005(B) 15=-1074(F) 16=-1005(B) 17=-1074(F) 18=-1074(F) 19=-1006(B) ,& WARNING - Verify design parameters andREAD NOTES ON THIS AND INCLUDED MfTEK REFERANCE PAGE M11-7473 rev. 10103)2015 BEFORE USE. Design valid for use only with Mffekg connectors. This design is based only upon parameters showni and Is for an Individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly Incorporate this design Into the overall building design. Bracing indicated Is to prevent buckling of Individual truss web and/or chord members only. Additional temporary and permanent bracing MiTek* Is always required for stability and to prevent collapse with possible personal Injury and property clarnage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, seeANSVT13ll Quality Cilterla, DSB-89 and BCSI BuldIng Component 6904 Parke East Blvd. Safety Informationavallable from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22�1 4. - Tampa, Fl- 33610 Job Tru s Truss Type A I Q ty ACQUAVISTA T15560588 75575 GRA HIP GIRDER 1 1 �Ply 2 � Job Uhambers Iruss, Inc., t-ort Pierce, F-L 1-11.6-001 - 0-0 6_ 3. .14 c� 2 1-:55 5.00FI-2 4x4 = LOADING (pso TCLL 20.0 TCDL 15.0 BCLL 0.0 BCDL 10.0 5x6 = 2X3 11 5x12 = 3 4 25 26 6 27 28 34 18 35 17 36 16 37 38 6X12 = 3X6 = 2X3 11 ts.iousmarii ;euitjmijeK1naUS1n8S,1nC. ivioni4ov tzuv;.jtP:ueeuta rage i 3-2-2 5x8 MT1 8HS 2X3 11 4x6 3x4 629 30 -7 31 8 32 33 9 9 15 39 4041 42 14 43 13 44 12 4x10 3x4 4x6 2x3 11 3-9-14 1-6-0 ' Scale = 1:61.9 7 03 C6 10 :Z� 107 Sx8 = 1;2-�O 23-1144 1_ 17-6-0 1 ��2 112 0130 u 1 2-2 5 0 1- — . _ 2. 4� 5-2-2 1 I 5� __ 5. 3-� 2 3_ 1 V�4 12,0-2-81, [7:0-3-0,Edgel, [9:0-5-12,0-2-81, [10:0-0-0,0-0-21 SPACING- 2-0-0 CS1. DEFL. in (loc) Ildefl Ud PLATES GRIP Plate Grip DOL 1.25 TC 0 ' 62 Vert(LL) 0.46 12-14 >702 240 MT20 244/190 Lumber DOL 1.25 BC 0.68 Vert(CT) 0.42 12-14 >771 180 MT18HS 244/190 Rep Stress Incr NO WB 0.92 Horz(CT) -0.06 10 n1a . n/a Code FBC2017/TP12014 Matrix -MS Weight: 338 lb FT = 20% LUIMIBER- BRACN%D TOPCHORD 2x4 SP M 30 TOPCHO BOTCHORD 2X4 SP M 30 BOTCHORD WEBS 2x4 SP No.3 *Except* 5-18: 2x4 SP M 30, 4-18: 2x6 SP No.2 REACTIONS. (lb/size) 2=-777/0-8-0,18=5389/0-8-0, 10=2143/0-8-0 Max Horz 2=1 89(LC 7) Max Uplift 2=-995(LC 18), 18=-8717(LC 8), 1 0=-3534(LC 8) Max Grav 2=1888(LC 6),18=5389(LC 1), 10=2143(LC 1) FORCES. (lb) -Max. Comp./Max. Ten. -All forces 250 (lb) or less except when showni TOPCHORD 2-3=-5055/3166, 3-4=-5325/3354, 4-5=-5325/3354, 5--6=-3742/6324, 6LB=-3742/6324, 8-9=-4887/8199, 9-10=-4574/7466 BOTCHORD 2-18=-2874/4863, 16-18=-792/547, 15-16=-792/547, 14-15=-7846/488 12-14=-6728/4182, 10-12=-6644/4138 WEBS 5-18=-4720[7754, 5-16=-1024/513, 5-15=-6049/3691, 6-15=-432/432, 8_115=-1342160, B-1 4=-792/383, 9-14=-1 367/908, 9-12=-1 695/898, 4-18=-231/303, 3-1 8=-1 658/2541 Structural wood sheathing directly applied or 6-0-0 oc pudins. Rigid ceiling directly applied or 5-4-8 oc bracing. NOTES- 1) 2-ply truss to be connected together with 1 Od (0.131 "x3") nails as follows: Top chords connected as follows: 2x4 - I row at 0-9-0 oc. Bottom chords connected as follows: 2x4 - I row at 0-5-0 oc. Webs connected as follows: 2x4 - I row at 0-9-0 oc, 2x6 - 2 rows staggered at 0-9-0 OC. 2) All loads are considered equally applied to all plies, except if noted as, front (F) or back (B) face in the LOAD CASE(S) section. Ply to. ply connections have been provided to distribute only loads noted as; (F) or (B), unless otherwise indicated. 3) Unbalanced roof live loads have been considered for this design. 4) Wind: ASCE 7-10; Vult=l 70mph (3-second gust) Vasd=1 32mph; TCDL=4.2psf; BCD ll=3.0psf; h=33ft; B=53ft; L=65ft;. eave=7ft; Cat. 11; Exp D; Encl., GCpi=0.18; MWFRS (directional); porch right exposed; Lumber DOL�1.60 plate grip DOL=1.60 6) Provide adequate drainage to prevent water ponding. 6) All plates are MT20 plates unless otherwise indicated. 7) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent witJ any other live loads. 8) * This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. I 9) Provide mechanical connection (by others) of truss to bearing plate capable of withsta ding 100 lb uplift at joint(s) except at=lb) 2=995,18=8717,10=3534. Walter P. Finn PE No.22839 MiTek USA, Inc. Fl. Carl 6634 6904 Parke East Blvd. Tampa FL 33610 Uate: November 12,2018 A WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MTTEKREFERANCE PAGE M11­7473 rev. 10103*015 BEFORE USE. Design valid for use only with M[Tek@) connectors. This design Is based only upon parameters shown, I and is for an Individual building component not a truss system. Before use, the building designer must verify the applicability of design parameters and properly Incorporate this design Into the overall building design. Bracing Indicated Is to prevent buckling of individual truss web and/or chord mem6ers only. Addlflonol temporary and permanent bracing Is always required for stability and to prevent collapse with possible personal Injury and property clorhage. For general guidance regarding the Mffek' fabrication, storage, delivery, erection and bracing of trusses and truss systems, seeANSVFPII Qualftj Criteria. DS6.89 and SCSI BuDding Component. 6904 Parke East Blvd. Safety Infamnationovallable from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 223,14. Tampa, FL 33610 Job Truss Truss Type Qty ply ACQUAVII TA T1556058B 75575 GRA HIP GIRDER 1 2 Job Refer nce (optional) Chambers Truss, Inc., Fort Pierce, FL NOTES- 10) Hanger(s) or other connection device(s) shal I be provided sufficient to support coi 9-0-12,157 lb down and 92 lb up at 11-0-12,157 lb down and 92 lb up at 13-0-1 down and 92 lb up at 17-11-4, 157 lb down and 92 lb up at 19-11-4, 157 lb down lb up at 25-11-4, and 268 lb down and 333 lb up at 28-0-0 on top chord, and 567 and 386 lb up at 11-0-12, 216 lb down and 386 lb up at 13-0-12, 216 lb down an up at 17-11-4, 216 lb down and 386 lb up at 19-11-4, 216 lb down and 386 lb up 25-11-4, and 567 lb down and 1044 lb up at 27-11-4 on bottom chord. The desic LOAD CASE(S) Standard 1) Dead + Roof Live (balanced): Lumber Increase=1.25, Plate Increase=1.25 Uniform Loads (plo Vert: 1-3=-70, 3-9=-70, 9-11 =-70, 19-22=-20 Concentrated Loads (lb) Vert: 3=-42(B) 7=-1 (B) 9=42(B) 12=-567(B) 25=-1 (B) 26=-1 (B) 27=-1 (B) 36=-216(B) 37=-216(B) 38=-216(B) 39=-216(B) 40=-216(B) 41=-216(B) � 8.130 s Mar-1 1 2018 MiTek Industries, Inc. Mon Nov 12 09:39:02 2018 Page 2 ID:aNkrWfLwRDXTOZhc4Bay—yKyKq-rXsMinOukHm]KD5CB2y—Wlkl?eyzaUag?1853tyJz7d centrated load(s) 268 lb down and 333 lb up at 7-0-0, 157 lb down and 92 lb up at !, 157 lb down and 92 lb up at 15-0-12,157 lb down and 92 lb up at 17-0-12,157 lb and 92 lb up at 21-11-4, 157 lb down and 92 lb up at 23-11-4, and 157 lb down and 92 lb down and 1176 lb up at 7-0-0, 216 lb down and 386 lb up at 9-0-12, 216 lb down 1386 lb up at 15-0�12, 216 lb down and 386 lb. up at 17-0-12, 216 lb down and 386 lb at 21-11-4, 216 lb down and 386 lb up at �341-4, and 216 lb down and 386 lb up at Vselection of such connection device(s) is the responsibility of others. ,& WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERANCE Design valid for use only with MiTek@ connectors. This design Is based only upon parameters shown a truss system. Before use, the building designer must verify the applicability of design parameters c building design. Bracing indicated Is to prevent buckling of Individual truss web and/or chord men Is always required for stability and to prevent collapse with possible personal Injury and property dc fabrication, storage, delivery, erection and bracing of trusses and truss systems, seeANSVTPII Quoit Safety Infafmationavollable from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22 (B) 29=-1 (B) 30=-1 (B) 31 =-1 (B) 32=-1 (B) 33=-1 (B) 34=-567(B) 35=-216(B) 6(B) 43=-216(B) 44=-216(B) IGE MIP7473 rev. 1010=2015 BEFORE USE. nd Is for an Individual building component, not J properly Incorporate this design Into the overall qrs only. Additional temporary and permanent bracing MiTek* age. For general guidance regarding the Criteria, DSB-89 and BCSI Bulding Component 4. 6904 Parke East Blvd. Tampa, FL 33610 Job Truss Truss Type A City Ply ACQUAVITA. T15560589 75575 GRB Roof Special Girder 1 2 Job Reference (optional) L;naMDers I russ, inc., i--orl rierce, 1--l- -1-6-0. 3-9-14 7-0-0 ts.iou s mar i i zuits mi I eK inclusines, Inc. man r4ov iz u-d:ou:uf zui tj rage i ID:aNkrWfLwRDXTOZhc4Bay—yKyKq-CUfFIV4lZpObR?zA—cy9DLR4TfaJFpGP9Zssk4yJz7) Scale = 1:62.9 7x8 MT1 8HS i 7x8 MT1 8HS 4x1 0 5x8 MT 3XB 5.0 0 rl —2 3 213 4 29 ,1BHS S r 30 31 7 32 33 8 - T I I — 7�14 MT18HS= 5x8 MT1 BHS c� 9 34 35 10 9 7 n 2 2 6 2j; 41iz� o 21 36 20 19 37 18 38 17 1639 15 14 40 13 4X10 44 5xB MT1 BHS 3x8 3x4 I I 7xB 3x4 11 5x1 2 MT1 8HS = 4x8 3x4 11 5x8 IVITI 8HS 2-:-11 1;0.0 11.-2-1144 15-4-0 19-5-2 22 8-.1-0 2�1 0 35-0-0 3 _ .14 1 4 2� 4-1-2 %0 4-1-2 4 4_ _0 4. 2-4-0 Plate Offsets (X,Y)-- [2:0-3-5,0-2-7], [3:0-5-0,0-2-8], 15:0-1-12,0-0-0], [6:0-4-0, Edge], [6:0-0-0,0-1-12], [8:0-4-0,0-2-2], [10:0-4-0,0-1 - 13], [11 :0-0-0,0-0-4] , 113:0-3-8,0-2-8], [15:0-4-0,0-3-01 1 LOADING (psf) SPACING- 2-0-0 CS1. DEFL. in (loc) I/defl Ud PLATES GRIP TCLL 20.0 Plate Grip DOL 1.25 TC 0.96 Vert'LL) 1,65 17-111 >254 240 MT20 244/190 TCDL 15.0 Lumber DOL 1.25 Bc 0.99 Vert(CT) -1.02 17-18 >411 240 MT18HS 244/190 BCLL 0.0 Rep Stress Incr NO WB 0.70 Horz(CT) -0.35 11 n/a n/a BCDL 10.0 Code FBC2017/TP]2014 Matrix -MS Weight: 358 lb FT = 20% LUMBER- BRACING- TOPCHORD 2x4 SP M 30 *Except* TOPCHORD 8-9: 2x6 SP 240OF 2.OE BOTCHORD BOTCHORD 2x4 SP M 30 *Except* 11 -16:2x4 SP M 31 WEBS 2x4 SP No.3 *Except* 9-15,9-13: 2x4 S P M 30 WEDGE Left: 2x4 SP No.3 REACTIONS. (lb/size) 2=3270/0-8-0,11=2762/0-8-0 Max Harz 2=1 89(LC 7) Max Uplift 2=-4754(LC 8), 11 =-3927(LC 8) FORCES. (lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when showni TOPCHORD 2-3=-7424/11016,3-4=-6884/10444, 4-5=-10213/15421, 5-7=-10213/15,421, 7-8=-8675/12894,8-9=-9105/13365,9-10=-6351/9018, 10-11=-6565/9270 BOTCHORD 2-21=-9907/6765, 20-21=-13438/9102,18-20=-13438/9102,17-18=-141532/9926, 15-17=-14532/9926,14-15=-20.955/14826,13-14=-20885/14794,11-13=-8383/6025 WEBS 3-21 =-3751/2431, 4-21 =-2818/4131, 4-20=-948/536,,4- 1 8=-2012/13871 5-1 8=-359/35 1, 7-18=-814/432, 7-17=-801/473, 7-15=-1 658/2516, 8-15=-4616/30641, 9115=-6567/9023, 9-14=-227/49319-13=-8689/12392, 10-i3=-3242/2299 I Structural wood sheathing directly applied or 4-8-8 oc purlins. Rigid ceiling directly applied or 2-6-9 oc bracing. NOTES- 1 ) 2-ply truss to be connected together with 1 Od (0. 131 "x3") nails as follows' Top chords connected as follows: 2x4 - 1 row at 0-7-0 oc, 2x6 - 2 rows staggered at 1-0 oc. Bottom chords connected as follows: 2x4 - 1 row at 0-7-0 oc. Webs connected as follows: 2x4 - I row at 0-9-0 oc, Except member 13-10 2x4 - 2 ro%L staggered at 0-2-0 oc. 2) All loads are considered equally applied to all plies, except if noted as front (F) or back (B) face in the LOAD CASE(S) section. Ply to ply connections have been provided to distribute only loads noted as (F) or (B), unless otherwise indicated. 3) Unbalanced roof live loads have been considered for this design. 1 4) Wind: ASCE 7-10; Vult=170mph (3-second gust) Vasd=132mph; TCDL=4.2psf; BCDL=3.Opsf; h=33ft; B=53ft; L=65ft; eave=7ft; Cat. 11; Exp D; Encl., GCpi=0.18; MWFRS (directional); Lumber DOL=1.60 plate grip DOL=�1.60 5) Provide adequate drainage to prevent water ponding. 6) All plates are MT20 plates unless otherwise indicated. 7) The Fabrication Tolerance at joint 3 = 12% 8) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with�any other live'loads. 9) * This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. I 10) Provide mechanical connection (by others) of truss to bearing plate capable of withst landing 100 lb uplift at joint(s) except at=lb) Walter P. Finn. PE No.22839 MiTok USA, Inc. FL Cod 6634 6904 Parke East Blvd. Tampa FL 33610 Date' November 12,2018 ,& wARNiNr. - Verify design parameters and REW NOTES ON THIS AND INCLUDED MITEKREFERANCE �AGE Mll-7473 rev. 1WO312015 BEFORE USE. Design valid for use only with MITek6 connectors. This design Is based only upon parameters shown, land Is for an Individual bulldln . g component, not a truss system. Before use, the building designer must verify the applicability of design parameters a6d properly incorporate this design Into the overall building design. Bracing Indicated Is to prevent buckling of Individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal InJury and property d#cge. For general guidance regarding the . Welk' fabrication, storage, delivery, erection and bracing of trusses and truss systems, seeANS[fTPIT Quo' Criteria, DSB-69 and BCSII Building Component 6904 Parke East Blvd. Safety Informationavallable from Truss Plate Institute, 218 N. Lee Street Suite 312, Alexandria, VA 22714. Tampa, IFIL 33610 Job Truss Truss Type A City Ply ACQUAVISTA . . . T15560589 : 75575 GRB Roof Special Girder 1 2 . I Job Reference (optional) Chambers Truss, Inc., Fort Pierce, FL NOTES- 11) Hanger(s) or other connection device(s) shall be provided sufficient to support cc 9-0-12, 157 lb down and 92 lb up at I 1 -0-12, 157 lb down and 92 lb up at 13-0- down and 92 lb up at 17-7-4, 157 lb down and 92 lb up at 19-7-4, 157 lb down E up at 30-7-4, and 342 lb down and 202 lb up at 32-8-0 on top chord, and 567 lb 447 lb up at 11-0-12, 216 lb down and 447 lb up at 13-0-12, 216 lb down and 4, 17-7-4, 216 lb down and 447 lb up at 19-7-4, 216 lb down and 447 lb up at 21-7 lb down and 76 lb up at 32-7-4 on bottom chord. The design/selection of such c LOAD CASE(S) Standard 1) Dead + Roof Live (balanced): Lumber Increase=1.25, Plate Increase=1.25 Uniform Loads (plo Vert: 1-3=-70, 3-8=-70, 8-9=-70, 9-1 0=-70, 10-12=-70, 22-25=-20 Concentrated Loads (lb) Vert: 3=-42(F) 8=-1 3(F) I 0=47(F) 21 =-567(F) 4=-1 (F) 20=-216(F) 18=- 31=-1 (F) 33=-1 (F) 34=-1 (F) 36=-216(F) 37=-216(F) Z18=-216(F) 39=-21 8.130 a Mar 11 2018 mi I eK Industries, Inc. Mon Nov 12 U9:3U:Uf ZU1 6, Page 2 ID:aNkrWfLwRDXTOZhc4Bay—yKyKq-CUfFIV4lZpObR?zA.cY9DLR4TfaJFpGP9Zssk4yJz7Y :entrated load(s) 268 lb down and 333 lb up at 7rO-O, 157 lb down and 92 lb up at 157 lb down and 92 lb up at 15-0-12, 157 lb down and 92 lb up at 16-7-4, 157 lb 192 lb up at 21-7-4, 241 lb down and 264 lb up at 23-8-0, and 138 lb down and 96 lb iwn and 1191 lb up at 7-0-0, 216 lb down and 447 lb up at 9-0-12i 216 lb down and lb up at 15-0-12, 216 lb down and 447 lb up at 15-7-4, 216 lb down and 447 lb up at 379 Ilb down and 836.1b up at 23-7-4, and 27 lb down and 29 lb up at 30-7-4., and 164 nection device(s) is the responsibility of other& ,& WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEKREFERANCEi Design valid for use only with MITek@ connectors, This design Is based only upon parameters shown, a truss system. Before use, the building designer must verity the applicability of design parameters a building design. Bracing indicated Is to prevent buckling of Individual truss web and/or chord mem Is always required for stability and to prevent collapse with possible personal Injury and property doi fabrication, storage, delivery, erection and bracing of trusses and truss systems, seeANSVIPI I Qualit Safety [nfafrnatlonovallable from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 2Z 5=-1 (F) 17=-216(F) 15=-379(F) 7=-1 (F) 13=41 (F) 28=-1 (F) 29=-1 (F) 30=-1 (F) )=-16(F) 11111-7473 rev. 10103)2015 BEFORE USE. Is for an Individual building component, not 'operly Incorporate this design Into the overall only. Additional temporary and permanent bracing MiTek' D. For general guidance regarding the 'aria, DSB-89 and BCSI Building Component 6904 Parke East Blvd. Tampa, FL 33610 Job Tru s Truss Type Qty Ply ACQUAVISTA T15560590 75575 GRC Hip Girder Job Reference (optional) Chambers Truss, Inc., Fort Pierce, FIL 3-9-14 3-2-2 5. 0 0 F1 _2 2 4x10 �� 3-9-14 8.130 s Mar 11 2018 MiTek Industries, Inc. Mon Nov 12 09:39:08 2018 Page 1 ID:aNkrWfLwRDXTOZhc4Bay—yKyKq-ghDdyr5fK7WS28YMXJ3OmZ—El�—)UKJYODbQGXyJz7X 13-0-0 16-2-2 20-0-0 . � 1 21-6-0 , 3-0-0 7XB MT1 8HS k� 3X8 = 7x8 MT1 8HS /I 3 18 � 4 19 5 11 10 20 9 21 8 1x1 WB 2X3 11 3X4 4x10 �� Scale = 1:37.5 LOADING (psf) SPACING- 2-0-0 CS1. DEFL. in (loc) I/defl Ud PLATES GRIP TCLL 20.0 Plate Grip DOL 1.25 TC 0.99 Vert(LL) 0.42 9-11 >569 240 MT20 244/190 TCDL 15.0 Lumber DOL 1.25 BC 0.71 Vert(CT) -0.25 9 >966 - 240 MT18HS 244/190 BCLL 0.0 Rep Stress Incr NO WB 0.39 Hor-z(CT) -0.14 6 n/a n/a BCDL 10.0 Code FBC2017rrPI2014 Matrix -MS Weight: 93 lb FT = 20% LUIMBER- BRACING - TOP CHORD 2x4 SP M 30 TOPCHORD Structural wood sheathing directly applied or 2-10-13 oc purlins. BOTCHORD 2x4 SP M 30 BOTCHORD Rigid ceiling directly applied or 2-11-14 oc bracing. WEBS 2x4 SP No.3 OTHERS 2x4 SP No.3 WEDGE Left: 2x4 SP No.3, Right: 2x4 SP No.3 REACTIONS. (lb/size) 2=1832/0-8-0, 6=183�/0-8-0 Max Horz 2=189(LC 7) Max Uplift 2=-2631 (LC 8), 6=-2631 (LC 8) FORCES. (lb) -Max. Comp./Max. Ten. -All forces 250 (lb) or less except when shown TOPCHORD 2-3=-3761/5603, 3-4=-3451/5373, 4-5=-3451/6372, 5-6=-3761/5603 BOTCHORD 2-11 =-4922/3392, 9-11 =-5395/3644, 8-9=-5395/3644, 6-8=-4922/3392 WEBS 3-1 1=-1 673/1035, 4-1 1=-388f748, 4-9=-838/316, 4-8=-388f748, 5-8=-1 NOTES- 1 ) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-10; Vult=170mph (3-second gust) Vasd=132mph; TCDL=4.2psf; BCD —3.0psf; h=33ft; B=53ft; L=65ft; eave=7ft; Cat. 11; Exp D; Encl., GCpi=0.18; MWFRS (directional); Lumber DOL=1.60 plate grip DOL 1.60 3) Provide adequate drainage to prevent water ponding. 4) All plates are MT20 plates unless otherwise indicated. 5) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 6) * This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 7) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) exceptot=lb) 2=263116=2631. 1 8) Hanger(s) or other connection clevice(s) shall be provided sufficient to support concentrated load(s) 268 lb down and 333 lb up at 7-0-6,157 lb down and 92 lb up at 0-0-12, and 157 lb down and 92,lb up at 10-11-4, 1 and 268 lb down and 333 lb up at 12-11 -10 on top chord, and 567 lb down and 1191 lb up at 7-0-0, 216 lb down and 447 lb up at 9-0-12, and 216 lb down and 447 lb up at 10-11-4, and 567 lb down and 1191 lb up at 12-11-4 on bottom chord. The design/selection of such connection device(s) is the responsibility of others. J 9) In the LOAD CASE(S) section, loads applied to the face of the truss are noted as froni I (F) or back (B). LOAD CASE(S) Standard 1) Dead + Roof Live (balanced): Lumber Increase=1.25, Plate Increase=1.25 Uniform Loads (plf) Vert: 1-3=-70, 3-5=-70, 5-7=-70,12-15=-20: Walter P. Finn PE N6.12839 MiTek USA, Inc. FL Carl 6634. 6904 Parke East Blvd. Tampa FL 33610 Date; November 12,2018 ,& WARNING - Verify design parameters and READ NOTES ON THISAND INCLUDED MITEKREFERANCE�AGEMII-7473 rev. 10103)2015 BEFORE USE Design valid for use only with MlTek0 connectors. This design is based only upon parameters shown land Is for an Individual building component, no a truss system. Before use, the building designer must verify the applicability of design parometers,;kd properly incorporate this design Into the ovei!.Il building design, Bracing Indicated Is to prevent buckling of Individual truss web and/or chord members only. Additional temporary and permanent bracing MOW is always required for stability and to prevent collapse with possible personal Injury and property do�nage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, seeANSVTPII Qualtlij Criforla, DSB-89 and 13CSI Bugdlng Companont 6904 Parke East Blvd. Safety Informationavallable from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314. Tampa, FL 33610 Job Tru s Truss Type Qty Ply ACQ UAVISTA T15560590 � 75575 GFIC Hip_ Girder 1 Job Reference (optional) Chambers Truss, Inc., Fort Pierce, I-L LOAD CASE(S) Standard Concentrated Loads (1b) Vert: 3=-42(F) 5=-42(F) 1 1=-567(F) 8=-567(F) 18=-l(F) 19=-l(F) 20=-21 8.1JUs Mar ii zuid mijeK inaustnes, Inc. man NOV 1Z UV:3�):Llb ZU11:5 vage z ID:aNkrWfLwRDXTOZhc4Bay—yKyKq-ghDdyr5fK7WS28YMXJ3OmZ_EI3_X__KJYODbQGXyJz7X 21=-2.16(F) WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERANCE P AGE 11,111-7473 rev. 1010,2015 BEFORE USE. , Design valid for use only with WOO connectors. This design Is based only upon parameters shown, and, Is for an Individual building component not a truss system. Before use, the building designer must verity the applicability of design parameters and properly Incorporate this design into the overall building design. Bracing Indicated Is to prevent buckling of Individual truss web and/or chord mernbers only. Additional temporary and permanent bracing MiTek' Is always required for stabllity and to prevent collapse with possible personal Injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, seeANSVI[I)III Quallt� Criteria. DSB-89 and BCSI Building Component 6904 Parke East Blvd. Salloty [nformatlanovallable from Truss Plate Institute, 218 N. Lee Street Suite 312, Alexandria, VA 223� 4. Tampa, FL 33610 Job Truss Truss Type i ! Qty Ply ACQUAVISTA I . T15560591 75575 GIRD Common.Girder I 2 Join Reference (optional) t,narrlDers i russ, inc., t-on rierce, r-L 0.113vb Ividl I I eu I o Ivil I un H luubulub, it lu. mul 1 1— — —ou. I u — I o rayu . 10.0.0 ID:aNkrWfLwRDXTOZhc4Bay—y�yKq-c3LNNW6vrkmAlSikfk6s�-3emsdjS8prrX4XLPyJz7V 5-3-14 1 1 14-8-2 1 20-0-0 P715CM 5. 0 0 F1 —2 6x10MT18HS 11 5x6 SX6 -- I I � -- Scale = 1:34.5 LI 11111 111111 11 Lu 1111 9 14 8 15� 7 16 17 6 18 19 5x12 MT18HS 3X10 11 6x10 MT18HS 1 lox10 = HUS26 3x10 11 HUS26 5x12WT1BHS HUS26 HUS26 HUS26 HUS26 HUS26 5-3-14 10-0-0 14-8-2 20-0-0 5-3-14 4-8-2 1 4-8-2 5-3-14 Plate Offsets (X,Y)-- [1:0-3-11,0-3-41,[5:0-3-11,0-3-41 1 LOADING (psf) SPACING- 2-0-0 CS1. DEFL. in (loc) I/defl Ud PLATES GRIP TCLL 20.0 Plate Grip DOL 1.25 TC 0.76 Vert(LL) 0.41 7-9 >579 240 MT20 244/190 TCDL 15.0 Lumber DOL 1.25 BC 0.95 Vert(CT) -0.40 7-9 >594 240 MT18HS 244/190 BCLL 0.0 Rep Stress Incr NO WB 0.78 Horz(CT) -0.11 5 n/a n/a BCDL 10.0 Code FBC2017frPI2014 Matrix -MS Weight: 209 lb FT = 20% LIUMBER- TOP CHORD 2X4 SP M 31 BOT CHORD 2x6 SP 240OF 2.OE WEBS 2x4 SP No.3 *Except* 3-7: 2x4 SP M 30 REACTIONS. (lb/size) 1=4930/0-8-0,5=7739/0-8-0 Max Harz 1 =221 (LC 7) Max Uplift 1=-4274(LC 8), 5=-6716(LC 8) FORCES. (lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown TOPCHORD 1-2=-1 2667/10995, 2-3=-1 0579/9254, 3-4=-1 0602/9263, 4-5=-1 6143/1 BOTCHORD 1-9=-10021/11646, 7-9=-10021/11646,6-7=-12853/14903, 5-6=-1285: WEBS 3-7=-6721 f7751, 4-7=-5715/5076, 4-6=-3459/4089, 2-7=-2124/1954, 2 BRACING- TOPCHORD Structural wood sheathing directly applied or 3-2-10 oc pudins. BOTCHORD Rigid ceiling directly applied or 5-5-115 oc bracing. 4903 =-11 135/1416 NOTES- 1) 2-ply truss to be connected together with 1 Od (0.131 "x3") nails as follows: Top chords connected as follows: 2x4 - 1 row at 0-7-0 oc. Bottom chords connected as follows: 2x6 - 2 rows staggered at 0-5-0 oc. Webs connected as follows: 2x4 - 1 row at 0-9-0 oc. 2) All loads are considered equally applied to all plies, except if noted as front (F) or bac : (B) face in the LOAD CASE(S) section. Ply to ply connections have been provided to distribute only loads noted as (F) or (B), unlesg otherwise indicated. 3) Unbalanced roof live loads have been considered for this design. 4) Wind: ASCE 7-10; Vult=1 70mph (3-second gust) Vasd=1 32mph; TCDL=4.2psf; BCD L1-3.0psf; h=33ft; B=53ft; L=65ft; eave=7ft; Cat. 11; Exp D; Encl., GCpi=0.18; MWFRS (directional); Lumber DOL=11.60 plate grip DOL-i.1.60 5) All plates are MT20 plates unless otherwise indicated. 6) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with' any other live loads. 7) * This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. I - 8) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) except Gt=lb) 1=4274,5=6716. 9) Use USP HUS26 (With 16d nails into Girder & 16d nails into Truss) or equivalent spaged at 2-0-0 oc max. starting at 7-2-12 from the left end to 18-5-4 to connect truss(es) to back face of bottom chord. 10) Fill all nail holes where hanger is in contact with lumber. I LOAD CASE(S) Standard Walter P. Finn PE No.22839 1) Dead + Roof Live (balanced): Lumber Increase=1.25, Plate Increase=1.25 MiTek USA, Inc. Fl. Cori 6634 Uniform Loads (plf) Vert: 1-3=-70, 3-5=-70,1-5=-20 8904 Parke East Blvd. Tampa FIL 33610 Date: November 12,2018 I -- WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERANCE PAGE 11411-7473 rev. 101=015 BEFORE USE. Design valid for use only with MiTekO connectors. This design Is based only upon parameters shown, 'and Is for an Individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters o0d properly incorporate this design Into the overall W1, building design. Bracing Indicated Is to prevent buckling of Individual truss web and/or chord members only. Additional temporary and permanent bracing MiTek' Is always required for stability and to prevent collapse with possible personal Injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, seeANSVJPII Quallti CrItarla. DSB-89 and BCSI BuIldlino Componont 6904 Parke East Blvd. Safety Infafirriatlonovallable from Truss Plate Institute, 218 N. Lee Street Suite 312, Alexandria, VA 2231� 4. Tampa, FL 33610 Job Truss Truss Type q I City Ply ACQUAVISTA - T15560591 75575 GRD Common Girder 1 2: inal) Chambers Truss, Inc., Fort Pierce, FIL I . 6.1du s mar ii 2uits miieK industries, Inc. man NOV 1Z UV:3U:1U ZUld vage z ID:aNkrWfLwRDXTOZhc4Bay—yKyKq-c3LNNW6vrkmAlSikfk6sr-3emsdjSBprrX4XLPyJz7V LOAD CASE(S) Standard Concentrated Loads (1b) Vert: 6=-1553(B) 14=-1553(B) 15=-1553(B) 16=-1553(B) 1-7=-1553(B) 181553(B) 19=-1553(B) i WARNING - Verify design parameters andREAD NOTES ON THIS AND INCLUDED MITEKREFERANCE PAGE M11-7473'.. 1WO312015 BEFORE USE. Design valid for use only with MITek@ connectors. This design Is based only upon parameters shown, and Is for an Individual building component, not a truss system. Before use, the building designer must verify the applIcablIlty of design parameters and properly Incorporate this design Into the overall building design. Bracing Indicated Is to prevent buckling of Individual truss web and/or chord members only. Additional temporary and permanent bracing MiT6k' Is always required for stability and to prevent collapse with possible personal Injury and property clamage For general guidance regarding the fabrication, storage, delivery, erection and bracIng of trusses and truss systems, seeANSV[Pll Quali� Cdto'do, DSB-89 and BCSI Building Component 6904 Pari(e East Blvd. Safety Informationovallable from Truss Plate Institute, 218 N. Lee Street Suite 312, Alexandria, VA 22314. Tampa, I'L 33610 Job Truss Truss Type City Ply ACQUAVISTA T15560592 75575 GRK Hip Girder 1 Job Reference (optional) Chambers Truss, Inc., Fort Pierce, Fl- 11, 5x8 MT18HS 5. 0 0 F1 —2 3x10 = 2x3 3-9-14 LOADING (psf) TCLL 20.0 TCDL 15.0 BCLL 0.0 BCDL 10.0 SPACING- 2-0-0 Plate Grip DOL 1.25 Lumber DOL 1.25 Rep Stress Incr NO Code FBC2017[TP12014 CS1. TC 0.83 BC 0.60 WB 0.28 Matrix -MS LUIMBER- TOPCHORD 2X4 SP M 30 BOTCHORD 2X4 SP M 30 WEBS 2x4 SP No.3 REACTIONS. (lb/size) 2=1442/0-8-0,5=1442/0-8-0 Max Harz 2=1 89(LC 24) Max Uplift 2=-2049(LC 8), 5=-2049(LC 8) FORCES. (lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when TOPCHORD 2-3=-2749/4092, 3-4=-2491/3937, 4�5=-2749/4092 BOTCHORD 2-9=-3526/2457, 7-9=-35B4/2491, 5-7=-3526N57 WEBS 3-9=-1 171 f724, 4-7=-1 171[794 8.130 a Mar 11 2018 MiTek Industries, Inc. Mon Nov 12 09:39:112018 Page I ID:aNkrWfLwRDXTOZhc4Bay—yKyKq-5Gvmbs7Xc2ulvcHxDRd5NBcoWG2QBiw?4Bq4tryJz7U Scale = 1:31.2 5xB MT1 8HS = 4x6 = 2X3 11 16-2-0 WO = DEFL. in (loc) I/defl Lid PLATES GRIP Vert(U-) 0.27 9-12 >713 . 240 MT20 244/190 Vert(CT) -0.25 7-15 >789 240 MT18HS 244/190 Horz(CT) -0.08 5 n/a n/a Weight: 63 lb FT = 20% BRACING- TOPCHORD Structural wood sheathing directly applied or 3-7-13 oc purlins. BOTCHORD Rigid ceiling directly applied or 3-8-0 oc bracing. 7 c? 17 NOTES- 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASIDE 7-10; Vult=170mph (3-second gust) Vasd=132mph; TCDL=4.2psf; BCDL3.0psf; h=33ft; B=53ft; L=65ft; eave=7ft; Cat. 11; Exp D; Encl., GCpi=0.18; MWFRS (directional); Lumber DOL=1.60 plate grip DOL= ' 60 3) Provide adequate drainage to prevent water ponding. 4) All plates are MT20 plates unless otherwise indicated. 5) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 6) * This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 1 7) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) except at=lb) 2=204915=2049. 1 8) Hanger(s) or other connection device(s) shall be provided sufficient to support concentrated load(s) 268 lb down and 333 lb up at 7-0-0, and 268 lb down and 333 lb up at 9-2-0 on top chord, and 567 lb down and 1191 lb up at 7-0-0, and 567 lb down and 1191 lb up at 9-1-4 on bottom chord. The design/selection of such connection device(s) is the responsibility of others. I 9) In the LOAD CASE(S) section, loads applied to the face of the truss are noted as front (F) or back (B). LOAD CASE(S) Standard 1) Dead + Roof Live (balanced): Lumber Increase=1.25, Plate Increase=1.25 Uniform Loads (plf) Vert: 1-3=-70, 3-4=-70, 4-6=-70,10-13=-20 Concentrated Loads (lb) Vert: 3=-42(B) 4=-42(B) 9=-567(B) 7=-567(B) Walter P. Finn PE N6.22839 M!Tek USA, Inc. FL Cert 6634 6904 Parke East Blvd. Tampa FL 31610 Date: November 12,2018 WARNING- Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEKREFERANCE PAI GEM11-7473rev. 1010312015 BEFORE USE. Design valid for use only with MITek@ connectors. This design Is based only upon parameters shown, and Is for an Individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters ana properly Incorporate this design into the overall building design. Bracing Indicated Is to prevent buckling of Individual truss web and/or chord members only. Additional temporary and permanent bracing MiTek'. Is always required for stability and to prevent collapse with possible personal Injury and property domb,ge. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, seeANSI/Tpll Quality Criteria, DSB-69 and BCSI Building Component 6904 Parke East Blvd. Safaty [nformationovallable from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 2231',4. Tampa, FIL 33610 Job Truss Truss Type City Ply ACQUAVII TA T15560593 75575 GRL Hip. Girder 1 1 Job Reference (optional) Chambers Truss, Inc.,, Fort Pierce, FL 8.130 a Mar 11 2018 MiTek Industries, Inc. Mon Nov 12 09:39:12 2018 Page 1 ID:aNkrWfLWRDXTOZhc4Bay—yKyKq-ZSTBoC8ANLOuXmr7m98KwP9?jg(?qw2S8JrZdPlyJz7T -1-6-0 3-0-0 7-4-9 11-7-7 16-0-0 1 19-0-0 1 20-6-0 . 1-6-0 3-0-Y, 4-4-9 4-2-13 4-4-9 3-0-0 Scale 1:35.8 5x8 MT18HS 5. 0 0 rl —2 2x3 3x4 5x8 MT18HS 3 20 21 224 23 24 5 25 26 27 6 2 7 13 28 29 12 1 11 30 10 31 32 9 2x3 2x3 3x5 4xB 3x5 3x5 7-4-9 �3-20-20 1 16-0-0 90-0 4-4-9 V 4-4-9 Plate Offsets (X,Y)-- [3:0-5-12,0-2-81,[6:0-5-12,0-2-81 LOADING (psf) SPACING- 2-0-0 CS1. DEFL. in (loc) I/defl Ud PLATES GRIP TCLL 20.0 Plate Grip DOL 1.25 TC 0.67 Vert(U-) 0.51 10-12 >443 240 MT20 244/190 TCDL 15.0 Lumber DOL 1.25 BC 0.58 Vert(CT) -0.34 10-12 >663 240 MT18HS 244/190 BCLL 0.0 Rep Stress Incr NO WB 0.77 Horz(CT) -0.07 7 n/a n/a BCDL 10.0 Code FBC2017/TP12014 Matrix -MS Weight: 87 lb FT = 20% LUMBER- TOPCHORD 2X4 SP M 30 BOTCHORD 2X4 SP M 30 WEBS 2x4 SP No.3 REACTIONS. (lb/size) 2=103010-8-0, 7=1030/0-8-0 Max Horz 2=1 OO(LC 31) Max Uplift 2=-1 350(LC 8), 7=-1 349(LC 8) Max Grav 2=1 088(LC 36), 7=1 088(LC 37) FORCES. (lb) - Max. Comp./Max. Ten. - All forces 2�O (lb) or less except when shoy TOPCHORD 2-3=-2128/2561, 3-4=-3262/4377, 4-5=-3262/4377, 5-6=-3263/4378, BOTCHORD 2-13=-2270/1995,12-13=-2284/2013,10-12=-4192/3299, 9-10=-228 7-9=-2271/1953 WEBS 3-12=-2051/1495, 4-12=-321/414, 5-1 0=-328/416, 6-1 0=-2054/1496 BRACING- TOPCHORD Structural wood sheathing directly applied or 3-9-15 oc purlins. BOTCHORD Rigid ceiling directly applied or 3-5-5 oc bracing. 970, NOTES- 1 ) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-10; Vult=170mph (3-second gust) Vasd=132mph; TCDL--4.2psf; BCDLII=3.Opsf; h=33ft; B=53ft; L=65ft; eave=7ft; Cat. 11; Exp D; Encl., GCpi=O. 18; MWFRS (directional); Lumber DOL=11.60 plate grip DOL=1 1 60 3) Provide adequate drainage to prevent water ponding. 4) All plates are MT20 plates unless otherwise indicated. 5) This truss has been designed for a 10.0 psf bottom chord live load r�onconcu �rent wirth� ny other live loads. 6) * This truss has been designed for.a live. load of 20.0psf on the bottc m chord In all a e here a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 1 7) Provide mechanical connection (by others) of truss to bearing plate capable of withsta in 100 Ito uplift atjoint(s) except Ot=lb) 2=1350,7=1349. 8) Hanger(s) or other connection device(s) shall be provided sufficient to support concent.r ted load(s) 271 lb down and 259 lb up at 3-0-0, 65 lb down and 116 lb up at 5-0-12, 65 lb down and 1 i 6 lb up at 7-0-12, 65 lb down and 116 lb up at 9-0-12, 65 lb down and 116 lb up at 9-11-4, 65 lb down and 116 lb up at 11 - 11-4, and 65 lb down and 116 lb ul p at 13-11-4, and 271 lb down and 259 lb up at 16-0-0 on top chord, and 124 lb down and 118 lb up at 3-0-0, 21 lb down and 84 lb'up at 5-0-12, 21 lb down and 84 lb up at 7-0-12, 21 lb down and 84 lb up at 9-0-12, 21 lb down and 84 lb up at 9-11-4, 21 lb down and 84 lb up at 11 -11-4, and 21 lb down and 84 lb up at 13-11-4, and 124 lb down and 118 I.b up at 15-11-4 on bottom chord. The design/selection of such connection device(s) is the responsibility of others. 1 9) In the LOAD CASE(S) section, loads applied to the face of the truss are noted as front (F) or back (B). LOAD CASE(S) Standard 1) Dead + Roof Live (balanced): Lumber lncrease=1.25, Plate lncrease=1.25 Uniform Loads (plf) Vert: 1-3=-70, 3-6=-70, 6-8=-70,14-17=-20 Walter P. Finn PE No.22839 MITek USA, In'c. FL Cott 6634 6904 Parke East Blvd. Tampa FL 33010 Data: November 12,2018 WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MTTEKREFERANCE P�GEM114473 rev. 1010312015 BEFORE USE. Design valid for use only with MITek@ connectors. This design Is based only upon parameters shown, and is for an Individual building component, not a truss system. Before use, the building designer must verity the applicability of design parameters and properly Incorporate this design Into the overall building design. Bracing Indicated Is to prevent buckling of Individual truss web and/or chord members only. Addiflonal temporary and permanent bracing MiTek' Is always required for stability and to prevent collapse with possible personal Injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, seeANSVTPI] Quallty.Cifforlo, DSB-89 and BCSl Buldillng Component Salloty Informationovallable from Truss Plate Institute, 218 N. Lee Street, Suite 312. AJexandria, VA 22311,4. 6904 Parke East Blvd. Tampa, FL 33610 Job Tru S Truss Type Qty Ply ACQUAVISTA I T15560593 75575 GFIL Hip Girder 1 1 Job Reference (optional) Chambers Truss, Inc., Fort Pierce, FL LOAD CASE(S) Standard Concentrated Loads (lb) Vert: 3=-5(F) 6=-5(F) 11=-1 1 (F) 13=-17(F) 9=-17(F) 21=-5(F) 22=-5(F) 8.130 s mar 11 zul 8 Mi I ex industries, Inc. man NOV i z ug:39:1 z zui tj rage z ID:aNkrWfLwRDXTOZhc4Bay—yKyKq-ZST8oC8ANLOuXmr7m98KwP9?jgOqw2SBJrZdP]yJz7T 24=-5(F) 25=-5(F) 26=-5(F) 28=- 11 (F) 29=-1 1 (F) 30=-1 1 (F) 31 =- I I (F) 32=- 11 (F) WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MfTEK REFERANCE Design valid for use only with MiTekO connectors. This design Is based only upon parameters shown, a truss system. Before use, the building designer must verity the applicability of design parameters building design. Bracing Indicated Is to prevent buckling of Individual truss web and/or chord membbrs PAGE M11-7473 rev. latMOIS BEFORE USE. a , nd, Is for an Individual building component not and properly Incorporate this design Into the overall only. Additional temporary and permanent bracing MiTek' Is always required for stability and to prevent collapse with possible personal injury and property damloge. fabrication, storage, delivery, erection and bracIng of trusses and truss systems, seeANSVMII QUOI Safety Informatlonovallable from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 227114, For general guidance regarding the C'dt*ft. DSB49 and BCSI Building Component 6904 Parke East Blvd. Tampa, Fl- . 33610 Job Truss Truss Type Cty Ply ACQUAVII TA T15560594 75575 GRP HIP GIRDER 1 1 Job Re rence optional) Chambers Truss, Inc., Fort Pierce, FL 8.130 s Mar 11 2018 MiTek Industries, Inc. Mon Nov 12 09:39:14 2018 Page 1 ID:aNkrWfLwRDXTOZhc4Bay—yKyKq-VrauDu9QvzGbm3?WuaAo?qEKUTzsOOHRm92kUAyJz7R .1-F;-n A-7-R 7.n.n ii-R-n 1 s.n.n . 1 R-4-1 n . qn-ri.n . 94-S-n . 1-6-0 4-7-6 2-4-10 4-6-0 4-6-0 2-4-10 4-7-6 Scale 1:42.4 6x10 MT18HS-- 3x10 6x10 MT18HS-- —2 4 20 21 225 23 24 25 6 5. 0 0 F1 2X3 2X3 c� 3 7 cf 2 8 L-L 1 9 13 26 12 27 11 28 29 10 5x14 6x8 5x8 MT1 8HS = 6x8 5x14 2x3 11 7 1-_1 11-6-0 16-0-0 L2 23-0-0 41-71 T_ _ �.Jo 443.0 4-6-0 I �4-1100 ___ 4-7-6 Plate Offsets (X,Y)-- r2:0-3-11,0-3-41, [4:0-6-12,0-2-121, r6:0-6-12,0-2-121, [7:0-0-0,0-01,01, f8:0-3-11,0-3-41 LOADING (psf) SPACING- 2-0-0 CS1. DEFL. in (loc) Vdefl Ud PLATES GRIP TCLL 20.0 Plate Grip DOL 1.25 TC 0.72 Verl(LL) 0.70 10-11 >394 240 MT20 244/190 TCDL 15.0 Lumber DOL 1.25 BC 1.00 Vert(CT) -0.39 10-11 >712 240 MT18HS 244/190 BCLL 0.0 Rep Stress Incr NO WB 0.56 Horz(CT) -0.24 8 n/a We BCDL 10.0 Code FBC2017[rPI2014 Matrix -MS Weight: 119 lb FT = 20% LUMBER - TOP CHORD 2x4 SP M 31 -Except' 4-6: 2x6 SP 240OF 2.OE BOT CHORD 2X4 SP M 30 WEBS 2x4 SP No.3 WEDGE Left: 2x4 SP No.3, Right: 2x4 SP No.3 REACTIONS. (lb/size) 2=2184/0-8-0, 8=2184/0-8-0 Max Horz 2=1 88(LC 7) Max Uplift 2=-361 1 (LC 8), 8=-361 1 (LC 8) FORCES. (lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOPCHORD 2-3=-4773/7792, 3-4=-4571/7670, 4-5=-4282/7268, 5-6=-4282/7268, 6- 7-8=-4773/7792 BOTCHORD 2-13=-6994/4349, 11-13=-8238/51 00, 10-11 =-8238/51 00, B-1 0=-6994/i WEBS 3-13=-b92/498, 4-13=-257211458, 5-13=-1 034/1593, 5-111 =-1 300f7l 0, f 6-1 0=-2571/1458, 7-1 0=-394/498 NOTES- 1 ) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-10; Vult=170mph (3-second gust) Vasd=132mph; TC DL=4.2psf; BCDLi 11; Exp D; Encl., GCpi=0.18; MWFRS (directional); porch left and right exposed; Lumbe 3) Provide adequate drainage to prevent water ponding. 4) All plates are MT20 plates unless otherwise indicated. 5) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with i 6) * This truss has been designed for a live load of 20.Opsf on the bottom chord in all area will fit between the bottom chord and any other members. 7) Provide mechanical connection.(by others) of truss to bearing plate capable of withstan 2=3611,8=3611. 8) Hanger(s) or other connection device(s) shall be provided sufficient to support concentr 7-0-0, 157 lb down and 92 lb up at 9-0-12, 157 lb down and 92 lb up at 11 -0-12, 157 It down and 92 lb up at, 13-11-4, and 268 lb down and 333 lb up at 16-0-0 on top chord, 216 lb down and 386 lb up at 9-0-12, 216 lb downand 386 lb up at 11-0-12, 216 lb dol down and 386 lb up at 13-11-4, and 567 lb down and 1044 lb up at 15-11-4 on bottom connection device(s) is the responsibility of others. 9) In the LOAD CASE(S) section, loads applied to the face of the truss are noted as front i LOAD CASE(S) Standard BRACING- TOPCHORD Structural wood sheathing directly applied or 3-5-0 oc purlins. BOTCHORD Rigid ceiling directly applied or 1-11-12 oc bracing. 0=-1034/1592, 3.Opsf; h=33ft; B=53ft; L=65ft; eave=7ft; Cat. DOL=1.60 plate grip DOL=1.60 iy other live loads. where a rectangle 3-6-0 tall by 2-0-0 wide 100 lb uplift at joint(s) except at=lb) ,ted load(s) 268 lb down and 333 lb up at down and 92 lb up at 11 -11-4, and 157 lb nd 567 lb down and 1044 lb up at 7-0-0, nand386lbupat 11-11-4,and2l6lb �hord. The design/selection of such :) or back (B). Walter P. Finn PE No.22839 MiTek USA, Inc. FL Cent 6634. 6904 Parke East Blvd. Tampa FL 33810 Date: November 12,2018 WARNING - Verify design parameters andREAD NOTES ON THIS AND INCLUDED MIT5KREFERANCE PAGE 11111-7473 rev. 1010312015 BEFORE USE. Design valid for use only with MITek6 connectors. This design Is based only upon parameters shown, a , no Is for an Individual building component not a truss system. Before use, the building designer must verity the applicability of design parameters an6 properly Incorporate this design Into the overall building design. Bracing Indicated Is to prevent buckling of Individual truss web and/or chord members only. Additional temporary and permanent bracing MOW Is always required for stability and to prevent collapse with possible personal Injury and property dombge. For general guidance regarding the fabrication, storage, delivery. erection and bracing of trusses and truss systems, seeANSV[pll Quall Criteria. DSB-89 and BCSI Building Component 6904 Parke East Blvd. Safety Informatlonovallable from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA22 4- Tampa, FL 33610 Job Truss Truss Type Cty Ply ACQUAVII TA T15560594 75575 GRP HIP GIRDER 1 1 Job Reference (optional) Chambers Truss, Inc., Fort Pierce, FIL ti.1ju s mar 11 zultj miieK industries, Inc. man NOVI Z MM:14 ZU"Id t-agez ID:aNkrWfLwRDXTOZhc4Bay—yKyKq-VrauDu9QvzGbm3?WuaAo?qEKUTzsOOHRm92kUAyJz7R LOAD CASE(S) Standard 1) Dead + Roof Live (balanced): Lumber Increase=1.25, Plate Increase=1.25 Uniform Loads (pif) Vert: 1-4=-70, 4-6=-70, 6-9=-70,14-17=-20 - Concentrated Loads (lb) Vert: 4=-42(B) 6=-42(B) 13=-567(B) 10=-567(B) 21=-I(B) 22=-1 (B) 23=-1 (P) 24=-1 (B) 26=-216(B) 27=-216(B) 28=-216(B) 29=-216(B) WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEKREFERANCE PAGE M11-7473 rev. 1WO312015 BEFORE USE. Design valid for use onlywith MITek0 connectors. This design Is based only upon parameters shown, a i nd Is for an Individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters ona properly Incorporate this design Into the overall building design. Bracing Indicated Is to prevent buckling of Individual truss web and/or chord membbrs only. Additional temporary and permanent bracing MiTek' Is always required for stability and to prevent collapse with possible personal Injury and property domhge. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, seeANSVTPIJ Qual Safety Informatlanovallable from Truss Plate Institute, 218 N. Lee Street, Suite 312, AJexandria, VA 22110. bitterla, DSB-69 and BCSII Building Componont 6904 Parke East Blvd. Tampa, FL 33610 Job Tru S Truss Type Qty , Ply ACQUAVISTA . T15560595 75575 GFIR Half Hip Girder 1 1 Job Re ference (optional) Lonamoers I russ, Inc., ran rierce, t-L 5.00 5_2 3x6 = 5X8 = b.­riju a mar i i zuitj Nn i eK inausines, inc. rvion tNiov iz uv;jv;io zv iv rage i ID:aNkrWfLwRDXTOZhc4Bay—yKyKq-z1 8GQEA2gGOSODaiSHhlYl mVItSl7Poa?poHOdyJz7Q 3X6 11 5x10 15 4 16 17 53x6 8 1 19 7 20 21 6 2X3 11 1 4x10 = 3X4 11 Scale = 1:29.2 13 16 Plate Offsets (X,Y)-- [3:0-5-12,0-2-81, [5:0-3-8,0-3-01 1 LOADING (pso SPACING- 2-0-0 CS1. DEFL in (loc) I/defl Ud PLATES GRIP TCLL 20.0 Plate Grip DOL 1.25 TC 0.75 Vert(LL) 0.28 7-8 >662 240 MT20 244/190 TCDL 15.0 Lumber DOL 1.25 BC 0.42 Vert(CT) -0.15 7-8 >999 240 BCLL 0.0 Rep Stress Incr NO WB 0.79 Horz(CT) -0.04 13 n/a n/a BCDL 10.0 Code FBC2017[TP[2014 Matrix -MS Weight: 74 lb FT = 20% LIUMBER- TOP CHORD 2X4 SP M 30 BOT CHORD 2X4 SP M 30 WEBS 2x4 SP No.3 OTHERS 2x4 SP No.3 REACTIONS. (lb/size) 2=1176/0-8-0,13=1275/0-3-8 Max Horz 2=277(LC 25) Max Uplift 2=-1 61 O(LC 8), 13=-1 925(LC 8) FORCES. (lb) -Max. Comp./Max. Ten. -All forces 250 (lb) or less except when shown. TOPCHORD 2-3=-2251/3157, 3-4=-2155/3241, 4-5=-2155/3241 BOTCHORD 2-8=-2986/2025, 7-8=-3012/2042, 6-7=-362/247 WEBS 3-8=-391/378, 3-7=-333/183, 4-7=-661/914, 5-7=-3148/2086, 5-13=-1 3( NOTES- 1 ) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-10; Vult=170mph (3-second gust) Vasd=132mph; TCDL=4.2psf; BCDL 11; Exp D; Encl.,'GCpi=0.18; MWFRS (directiorfal); Lumber DOL=11.60 plate grip DOL=, 3) Provide adequate drainage to prevent water ponding. 4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with 5) * This truss has been designed for a live load of 20.Opsf on the bottom chord in all aree will fit between the bottom chord and any other members. 6) Bearing at joint(s) 13 considers parallel to grain value using ANSVTPI 1 angle to grain, capacity of bearing surface. 7) Provide mechanical connection (by others) of truss to bearing plate capable of withstar 2=1610,13=1925. 8) Hanger(s) or other connection device(s) shall be provided sufficient to support concent 5-0-0,112 lb down and 229 lb up at 7-0-12,112 lb down and 229 lb up at 9-0-12,112 and 229 lb up at 11 -3-4, and 112 lb down and 229 lb up at 13-3-4, and 106 lb down at 136 lb down and 273 lb up at 5-0-0, 52 lb down and 154 lb up at 7-0-12, 52 lb down a up at 9-3-4, 52 lb down and 154 lb up at 11 -3-4, and 52 lb down and 154 lb up at 13-: on bottom chord. The design/selection of such connection device(s) is the responsibik 9) In the LOAD CASE(S) section, loads applied to the face of the truss are noted as front LOAD CASE(S) Standard 1) Dead + Roof Live (balanced): Lumber Increase=11.25, Plate Increase=1.25 Uniform Loads (plo Vert: 1-3=-70, 3-5=-70, 6-10=-20 BRACING- TOPCHORD Structural wood sheathing directly applied or 4-6-12 oc purlins, except end verticals. BOTCHORD Rigid ceiling directly applied or 3-11-12 oc bracing. WEBS 1 Row at midpt 5-7 961 ; h=33ft; B=53ft; L=65ft; eave=7ft; Cat. .60 ry other live loads. where a rectangle 3-6-0 tall by 2-0-0 wide Building designer should verify 100 lb uplift at joint(s) except at=lb) ed load(s) 359 lb down and 533 lb up at down and 229 lb up at 9-3-4, 112 lb down 227 Ilp up at 15-0-12 on top chord, and ' 154 lb up at 9-0-12, 52 lb down and 154 lb 1, and 75 lb down and 148 lb up at 15-0-12 of others. ) or back (B). Walter P. Finn PE No.22839 M!Tek USA, Inc. Fl. Cart 6634, 6904 Parke East Blvd. Tampa FL 33610 Date: November 12,2018 WARNING - Verity design parameters and READ NOTES ON THISAND INCLUDED MITEKREFERANCE PAIGE 111114473 rev. 1010312015 BEFORE USE ' Design valid for use only.with MITek6 connectors. This design Is based only upon parameters shown, and Is for an Individual building component, n�'N a truss system. Before use, the building designer must verity the applicability of design parameters andiproperly incorporate this design Into the overall building design. Bracing Indicated Is to prevent buckling of Individual truss web and/or chord members only. Additional temporary and permanent bracing Is always required for stability and to prevent collapse with possible personal Injury and property damage. For general guidance regarding the M!Tek' fabrication, storage, delivery, erection and bracing of trusses and truss systems, seeANSIMII Quality Criteria. DSB-89 and BCSI Building Component 6904 Parke East Blvd. Safety Informationavallable from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314� I Tampa, FL 33610 Job Tru S Truss Type Qty Ply ACQUAVISTA T15560595 75575 GRR Half Hip Girder 1 1 . Job Reference (optional) Chambers Truss, Inc., Fort Pierce, FL LOAD CASE(S) Standard Concentrated Loads (lb) Vert: 3=-159(F) 6=-55(F) 8=-90(F) 5=-105(F) 14=-73(F) 15=-146(F) 16=- 8.130 s Mar 11 2018 MiTek Industries, Inc. Mon Nov 12 09:39:15 2018 Page 2 ID:aNkrWfLwRDXTOZhc4Bay—yKyKq-zlBGQEA2gGOSODaiSHhlYlmV[tSl7Poa?poHOdyJz7Q 17=-73(F) I 8=-43(F) 19=-87(F) 20=-43(F) 21 =-43(F) ,&WARNING -Verify design parameter. and READ NOTES ON THIS AND INCLUDED MIDEKREFERANCEPA'GE11111-7473 rev. 1010&2015 BEFORE USE. Design valid for use only with MiTek@ connectors. This design Is based only upon parameters shown, and Is for an Individual building component, not wt a truss system. Before use, the building designer must verify the applicability of design parameters and properly Incorporate this design Into the overall building design. Bracing Indicated Is to prevent buckling of individual truss web and/or chord membdrs only. Additional temporary and permanent bracing Mffek' Is always required for stability and to prevent collapse with possible personal Injury and property damage. For general guidance regarding the . fabrication, storage, delivery. erection and bracing of trusses and truss systems, seeANSIMIJ Quality Cifforla, DSB-89 and BCSI Building Component 6904 Parke East Blvd. Safety Informalfonavollable from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314, Tampa, FL 33610 Job Truss Truss Type ply ACQUAVISTA T15560596 75575 A JACK -OPEN �Qty 28 1 � Job Reference (optional) unarnDers I russ, Inc., t-on merce, I`-L 1-6-0 5.00 b.iou a iviar 1 1 eU 10 IVU I UK IT IIJIUSUIUS, UIG. IVIUII INIUV 14 UZI;OU; 10 eu 10 rage I ID:aNkrWfLwRD)CrOZhc4Bay—yKyKq-RDi.feaBgRaWJON9u??DG4FJgyHtFs2SkDTXrY3yJz7P 1-0-0 1-0-0 Scale = 1:7.1 3 2 4 3x4 = LOADING (psi) SPACING- 2-0-0 CS1. DEFL. in (loc) I/defl Ud TCLL 20.0 Plate Grip DOL 1.25 TIC 0.65 Vert(LL) -0.00 5 >999 240 TCDL 15.0 Lumber DOL 1.25 BC 0.11 Vert(CT) 0.00 5 >999 240 BCLL 0.0 Rep Stress Incr YES WB 0.00 Horz(CT) 0.00 4 n/a n/a BCDL 10.0 Code FBC2017rrPI2014 Matrix -MP LIUMBER- TOPCHORD 2x4 SP No.3 BOTCHORD 2x4 SP No.3 REACTIONS. (lb/size) 3=-8/Mechanical, 2=229/0-8-0, 4=-27/Mechanical Max Harz 2=123(LC 12) Max Uplift 3=-8(LC 1), 2=-390(LC 12), 4=-27(LC 1) Max Grav 3=40(LC 12), 2=229(LC 1), 4=82(LC 12) FORCES. (1b) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. NOTES- 1) Wind: ASCE 7-10; Vult=170mph (3-second gust) Vasd=132mph; TCDL=4.2psf; BCDL 11; Exp D; Encl., GCpi=0.18; MWFFIS (directional) and C-C Exteriorl zone; porch left forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 2) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with 3) * This truss has been designed for a live load of 20.Opsf on the bottom chord in all are will fit between the bottom chord and any other members. 4) Refer to girder(s) for truss to truss connections. 5) Provide mechanical connection (by others) of truss to bearing plate capable of withsta 2=390. PLATES GRIP MT20 244/190 Weight: 6 lb FT = 20% EIRACING- TOPCHORD Structural wood sheathing directly applied or 1-0-0 oc purlins. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. i.Opsf; h=33ft; B=53ft; L=65ft; eave=7ft; Cat. d right expo§ed;C-C for members and iy other live loads. where a rectangle 3-6-0 tall by 2-0-0 wide 100 lb uplift at joint(s) 3, 4 except at=lb) Walter P. Finn PE No.22839 MiTek USA, Inc. FL Cert 6634 6904 Parke East Blvd. Tampa FL 33610 Date: November 12,2018 ,& WARNING - Verify design parameters andRE4D NOTES ON THISAND INCLUDED MITEKREFERANCE PA6E MIP7473 rev. laG312015 BEFORE USE. . Design valid for use only with MiTek@ connectors. This design Is based a nly upon parameters shown, aqd Is for an Individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and, properly Incorporate this design Into the overa building design. Bracing Indicated Is to prevent buckling of Individual truss web and/or chord members only. Additional temporary and permanent bracing Is always required for stability and to prevent collapse with possible personal Injury and property damage. For general guidance regarding the . MOW fabrication, storage, delivery, erection and bracing of trusses and truss systems, seeANSIMIJ Quality Criferia. D511-89 and BCSI Building Component 6904 Parke East Blvd. Safety Informationovallable from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314� Tampa, FL 33610 Job Truss Truss Type Cty Ply ACQUAVII TA T15560597 75575 J3 JACK -OPEN 29 1 Job Reference (optional) Chambers Truss, Inc_ Fort Pierce, FIL 8.13o s mar 11 zuib MiTek industries, inc. Man Nov liz 09:39:itj zuiti flage 1 ID:aNkrWfLwRDXTDZhc4Bay—yKyKq-RDifeaBgRaWJONgu??DG4FJgyHops2SkDTXrY3yJz7P .1-6-0 3-0-0 1-6-0 3-0-0 Scale 1: 11.3 3 Ir 5.001 7 C� 2 4 3x4 3-0-0 3-0-0 Plate Offsets (X,Y)-- f2:0-0-6,0-0-01 LOADING (psf) SPACING- 2-0-0 CS1. DEFL. in floc) I/clefl L/d PLATES GRIP TCLL 20.0 Plate Grip DOL 1.25 TC 0.65 Vert(LL) 0.02 4-7 >999 240 MT20 244/190 TCDL 15.0 Lumber DOL 1.25 BC 0.39 Vert(CT) -0.01 4-7 >999 240 BCLL 0.0 Rep Stress Incr YES WB 0.00 Horz(CT) -0.00 3 n1a n1a BCDL 10.0 Code FBC2017/TP[2014 Matrix -MP Weight: 12 Ito FT = 20% LUMBER- TOPCHORD 2x4 SP No.3 BOTCHbRD 2x4 SP No.3 REACTIONS. (lb/size) 3=74/Mechanical, 2=26410-8-0, 4=31/Mechanical Max Harz 2=1 97(LC 12) Max Uplift 3=-1 04(LC 12), 2=-426(LC 12), 4=-76(LC 9) Max Grav 3=75(LC 17), 2=264(LC 1), 4=51 (LC 3) FORCES. (lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. NOTES- 1) Wind: ASCE 7-10; Vult=170mph (3-second gust) Vasd=132mph; TCDL=4.2psf; BI 11; Exp D; Encl., GCpi=0.18; MWFRS (directional) and C-C Exterior(2) zone; porch forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 2) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent, 3) * This truss has been designed for a live load of 20.Opsf on the bottom chord in all will fit between the bottom chord and any other members. 4) Refer to girder(s) for truss to truss connections. 5) Provide mechanical connection (by others) of truss to bearing plate capable of vvitl� 3=104,2=426. IBRACING- TOPCHORD Structural wood sheathing directly applied or 3-0-0 oc puffins. BOTCHORD Rigid ceiling directly applied or 10-0-0 oc bracing. =3.Opsf; h=33ft; B=53ft; L=65ft; eave=7ft; Cat. and right exposed;C-C for members and any other live loads. is where a rectangle 3-6-0 tall by 2-0-0 wide 100 lb uplift at joint(s) 4 except at=lb) Walter P. Finn PE No.22839 MiTek USA, Inc. FL Cert 66 , 34 6904 Parke East Blvd. Tampa FIL 33610 Date: November 12,2018 ,&WARNING -Vedry design parameters and READ NOTES ON THIS AND INCLUDED mrrEKREFERANCEPAIGEMIP7473 rev. 1010312015 BEFORE USE. Design valid for use only with MITek9) connectors. This design Is based only upon parameters shown, a , nd Is for an Individual building component, not ci truss system. Before use, the building designer must verity the applicability of design parameters and properly Incorporate this design Into the overall building design. Bracing Indicated Is to prevent buckling of Individual truss web and/or chord members only. Additional temporary and permanent bracing MiTek* Is always required for stability and to prevent collapse with possIble personal Injury and property dorr�oge. For general guidance regarding the . fabrication, storage, delivery, erection and bracing of trusses and truss systems, seeANSVWII QualifyCrItedo, DSB-89 and BCSI 1130ding Component Safety Informotlonovallable from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314. 6904 Parke East Blvd. Tampa, FL 33610 Job Tru S Truss Type Qty Ply AC QUAVISTA T15560598 75575 J3A Jack -Open Job Reference (optional) Chambers Truss, Inc., Fort Pierce, FL 8.130 s Mar 112018 MiTek Industries, Inc. Mon Nov 12 09:39:17 2018 Page 1 1 D:aNkrWfLwRDXTOZhc4Bay—yKyKq-vQG1 rwC[CufAdXk5ZikVdSspGh5TbVftS7HO5VyJz7O —3-8-0 3-8-0 3X4 4X4 11 LOADING (psf) SPACING- 2-0-0 CS1. DEFL in (loc) Vdefl Ud TCLL 20.0 Plate Grip DOL 1.25 TC 0.81 Vert(LL) -0.01 3-4 >999 360 TCDL 15.0 Lumber DQL 1.25 BC - 0.62 Vert(CT) -0.02 3-4 >999 240 BCLIL 0.0 Rep Stress Incr YES WB 0.00 Horz(CT) -0.03 2 We n1a BCDL 10.0 Code FBC2017/TP12014 Matdx-MR Wind(LL) 0.03 3-4 >999 240 LUMBER - TOP CHORD 2x4 SP No.3 BOT CHORD 2x4 SP No.3 WEBS 2x4 SP No.3 REACTIONS. (lb/size) 4=156/0-8-0,2=112/Mechanical,3=44/MechanicaI Max Harz 4=1 32(LC 12) Max Uplift 4=-81 (LC 12), 2=-1 65(LC 12), 3=-21 (LC 12) Max Grav 4=1 59(LC 17), 2=1 31 (LC 17), 3=68(LC 3) FORCES. (lb) -Max. Comp./Max. Ten. -All forces 250 (lb) or less except when shown. NOTES- 1) Wind: ASCE 7-10; Vult=170mph (3-second gust) Vasd=132mph; TCDL=4.2psf; BC 11; Exp D; Encl., GCpi=0.18; MWFRS (directional) and C-C Exterior(2) zone;C-C for shown; Lumber DOL=1.60 plate grip DOL=11.60 2) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent %A 3) * This truss has been designed for a live load of 20.Opsf on the bottom chord in all c will fit between the bottom chord and any other members. 4) Refer to girder(s) for truss to truss connections. 5) Provide mechanical connection (by others) of truss to bearing plate capable of with! 2=165. Scale = 1: 15.0 PLATES GRIP MT20 244/190 Weight: 12 lb FT = 20% BRACING- TOPCHORD Structural wood sheathing directly applied or 3-8-0 cc pudins, except end verticals. BOTCHORD Rigid ceiling directly applied or 10-0-0 cc bracing. Opsf; h=33ft; B=53ft; L=65ft; eave=7ft; Cat. )ers and forces & MWFRS for reactions iy other live loads. where a rectangle 3-6-0 tall by 2-0-0 wide 100 lb uplift at joint(s) 4, 3 except at=lb) Walter P. Finn PE No.22839 MiTek USA, Inc. FL Cart 6634. 6904 Parke East Blvd. Tampa FL 33610 Date: November 12,2018 WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERANCE PAGE MX7473 rev. 101=015 BEFORE USE. Design valid for use only with MiTek@ connectors. This design Is based only upon parameters shown, c1nd is for an Individual building component not a truss system. Before use, the building designer must verify the applicability of design porameters and properly Incorporate this design Into the overall building design. Bracing Indicated is to prevent buckling of Individual truss web and/or chord members only. Additional temporary and permanent bracing Mffek' Is always required for stability and to prevent collapse with possible personal Injury and property darnbge. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, seeANSVIPII Quollhr Critero. D5111-89 and BCSI BuUdlng Component 6904 Parke East Blvd. Safety [nforrnationavoilable from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22311,4. Tampa, FL 33610 Job Truss Truss Type City Ply ACQUAVII TA T15560599 75575 J5 JACK -OPEN 26 1 Job Reference (optional) L,namoers I russ, Inc., rort rierce, rL miju s mar i i zuits mi I eK industries, Inc. man r,4ov iz uu:oun / zuitj rage i ID:aNkrWfLwRDXTOZhc4Bay—yKyKq-vQG1 rwClCufAdXk5ZiWdSsuAh7ubVitS7HO5VyJz7O 5-d-0 Scale = 1: 15.4 5.00 1'2 7 T 6 C� 2 4 3x5 = LOADING (psf) SPACING- 2-0-0 CSI. DEFL. in (loc) I/defl Ud PLATES GRIP TCLL 20.0 Plate Grip DOL 1.25 TC 0.50 Vert(LL) 0.16 4-7 >373 240 MT20 244/190 TCDL 15.0 Lumber DOL 1.25 BC 0.46 Vert(CT) -0.05 4-7 >999 240 BCLL 0.0 Rep Stress Incr YES WB 0.00 Horz(CT) -0.00 3 n/a n/a BCDL 10.0 Code FBC2017fTP12014 MatHx-MP Weight: 18 lb FT = 20% LIUMBEF11- TOPCHORD 2X4 SP M 30 BOTCHORD 2x4 SP M 30 REACTIONS. (lb/size) 3=143/Mechanical, 2=343/0-8-0, 4=63/Mechanical Max Horz 2=273(LC 12) Max Uplift 3=-208(LC 12), 2=-525(LC 12), 4=-1 39(LC 12) Max Grav 3=147(LC 17), 2=343(LC 1), 4=92(LC 3) FORCES. (lb) -Max. Comp./Max. Ten. -All forces 250 (lb) or less except when shown. NOTES- 1) Wind: ASIDE 7-10; Vult=170mph (3-second gust) Vasd=132mph; TCDL=4.2psf; BCDL 11; Exp D; Encl., GCpi=0.18; MWFRS (directional) and C-C Exterior(2) zone; porch left forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 2) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with 3) * This truss has been designed for a live load of 20.Opsf on the bottom chord in all are will fit between the bottom chord and any other members. 4) Refer to girder(s) for truss to truss connections. 5) Provide mechanical connection (by others) of truss to bearing plate capable of withsta 3=208,2=525,4ml39. IBRACING- TOPCHORD Structural wood sheathing directly applied or 5-0-0 oc purlins. BOTCHORD Rigid ceiling directly applied or 10-0-0 oc bracing. :3.Opsf; h=33ft; B=53ft; L=65ft; eave=7ft; Cat. Ind right exposed;C-C for members and iny other live loads. s where a rectangle 3-6-0 tall by 2-0-0 wide 100 lb uplift at joint(s) except at=lb) Walter P. Finn PE No.22839 MiTek USA, Inc. Fl. Cert 6634 69D4 Parke East Blvd. Tampa FL 13610 Date: November 12,2018 WARNING - Verilrydesign parameters and READ NOTES ON THISAND INCLUDED MrTEK REFERANCE PAGE M11­7473 rev. 1010312016 BEFORE USE. Design valid for use only with MITek1D connectors. This design is bo . sod only upon parameters shown, aS' d Is for an Individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameter an s , building design. Bracing Indicated Is to prevent buckling of Individual truss web and/or chord members properly Incorporate this design Into the overall only. Additional temporary and permanent bracing MiTek' Is always required for stability and to prevent collapse with possible personal Injury and property dam6ge. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, seeANSVIP11 Quality CrIllarla, DS11-89 and III BuldIng Component 6904 Pari(e East Blvd. Safety Informationavallable from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22311. Tampa, FL 33610 Job Truss Truss Type Qty Ply ACQUAVISTA T15560600 75575 J7 JACK -OPEN 34 1 Job Reference (optional) Chambers Truss, Inc., Fort Pierce, FIL -1-6-0 4-2-13 3x1 0 �� Plate Offsets (X,Y)-- 5.00 8.130 s Mar 11 2018 MiTek Industries, Inc. Mon Nov 12 09:39:18 2018 Page 1 ID:aNkrWfLwRDXTOZhc4Bay—yKyKq-NcqP3FCwzBn1 FhJH7PFk9gO1 R5SKKu?1 hnOydxyJz7N Z-0-0 2-9-3 3X5 '�' 10 LOADING (psf) SPACING- 2-0-0 CSI. DIEFL. in (loc) Vdefl Ud TCLL 20 Plate Grip DOL 1.25 TC 0.59 Vert(LL) 0.34 6-9 >245 240 TCDL 1 0 5:0 Lumber DOL 1.25 BC 0.51 Vert(CT) -0.12 6-9 >688 240 BCLL 0.0 Rep Stress Incr YES WB 0.32 Horz(CT) -0.01 5 n/a n/a BCDL 10.0 Code FBC2017ITP[2014 Matrix -MP i LUMBER - TOP CHORD 2X4 SIP M 30 BOT CHORD 2X4 SP M 31 WEBS 2x4 SP No.3 WEDGE Left: 2x4 SP No.3 REACTIONS. (lb/size) 4=65/Mechanical, 2=429/0-8-0,5=236/Mechanical Max Harz 2=349(LC 12) Max Uplift 4=-83(LC 12), 2=-637(LC 12), 5=-427(LC 12) Max Grav 4=93(LC 17), 2=429(LC 1), 6=236(LC 1) FORCES. (lb) -Max. Comp./Max. Ten. -All forces 250 (lb) or less except when shown. TOPCHORD 2-3=-324/540 BOTCHORD 2-6=-8911367 WEBS 3-6=-439/1067 6 6x8 Scale = 1:19.9 PLATES GRIP MT20 244/190 Weight: 30 lb FT = 20% BRACING- TOPCHORD Structural wood sheathing directly applied or 6-0-0 oc pudins. BOTCHORD Rigid ceiling directly applied or 6-4-7 oc bracing. NOTES- 1) Wind: ASCE 7-10; Vult=170mph (3-second gust) Vasd=132mph; TCDL=4.2psf; BCDLi3.Opsf; h=33ft; B=53ft; L=65ft; eave=7ft; Cat. 11; Exp D; Encl., GCpi=0.18; MWFFIS (directional) and C-C Exterior(2) -1-6-0 to 4-11-1� 1 , Interion(l) 4-11-13 to 6-11-4 zone; porch left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 2) This truss has been designed fora 10.0 psf bottom chord live ioad nonconcurrent with a nyother live loads. 3) * This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 4) Refer to girder(s) for truss to truss connections. 5) Provide mechanical connection (by others) of truss to bearing plate capable of withstan d1ing 100 lb Uplift at joint(s) 4 except Ot=lb) 2=637,5=427. Walter P. Finn PIE No.22839 MiTek USA, Inc. EL Cert 66 9 6904 P&kelast Blvd. Tampa FL 33610 Date: November 12,2018 WARNING- Ventlydesign parameters and READ NOTES ON THISAND INCLUDED MITEKREFERANCE PA6E MIP7473 rev. la(0312016 BEFORE USE. Design valid for use only with MITek8 connectors. This design Is based only upon parameters shown, cQ'd a truss system. Before use, the building designer must verity the applicability of design parameters and1properly Is for an Individual building component, not Incorporate this design Into the overall wt building design. Bracing indicated Is to prevent buckling of Individual truss web and/or chord members is always required for stability and to prevent collapse with possible personal Injury and property damdge. only. Additional temporary and permanent bracing For general guidance regarding the MiTek' fabrication, storage, delivery, erection and bracing of trusses and truss systems, seeANSVFPII Quality Criteria, DSB-89 and I3CSI Bulding Component 6904 Parke East Blvd. Safety Informationovallable from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314. Tampa, FL 33610 Job Truss Truss Type Qty Ply ACQUAVISTA T15560601 75575 JA Jack -Open i - Job Reference (optional) L;naMDers I russ, Inc., vort vierce, VL 2 0 5.00 3X4 = 8.130 s mar 11 zu'lu Mi I ek Inausines, Inc. Mon Nov 12 UU:UU11:1 ZU18 Vage 1 ID:aNkrWfLwRDXTOZhc4Bay—yKyKq-NcqP3FCwzBn1 FhJH7PFk9gOOS5Y—KyylhnOydxyJz7N 2-4-0 2-4-0 Scale = 1:9.9 3 T I? 6 4 LOADING (psf) SPACING- 2-0-0 CS1. DEFL. in (loc) Vdefl Ud PLATES GRIP TCLL 20.0 Plate Grip DOL 1.25 TC 0.65 Ven(LL) -0.00 7 >999 360 MT20 244/190 TCDL 15.0 Lumber DOL 1.25 BC 0.15 Vert(CT) -0.00 7 >999 240 BCLL 0.0 Rep Stress Incr YES WB 0.00 Horz(CT) -0.00 3 n/a n/a BCDL 10.0 Code FBC2017ITP]2014 Matrix-Ml? Wind(LL) -0.00 7 >999 240 Weight: 10 Ito FT = 20% LIUMBER- BRACING- TOPCHORD 2x4 SP No.3 TOPCHORD Structural wood sheathing directly applied or 2-4-0 oc purlins. BOTCHORD 2x4 SP No.3 BOTCHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS. (lb/size) 3=50/Mechanical, 2=242/0-8-0, 4=18/Mechanical Max Harz 2=172(LC 12) Max Uplift 3=-51 (LC 12), 2=-333(LC 12) Max Grav 3=60(LC 17), 2=242(LC 1), 4=36(LC 3) FORCES. (lb) -Max. Comp./Max. Ten. -All forces 250 (lb) or less except when shown. NOTES- 1) Wind: ASCE 7-10; Vult=170mph (3-second gust) Vasd=132mph; TCDL=4.2psf; BCDIL=3.Opsf; h=33ft; B=53ft; L=65ft; eave=7ft; Cat. 11; Exp D; Encl., GCpi=0.18; MWFRS (directional) and C-C Exterior(2) zone;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 2) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with Iny other live loads. 3) * This truss has been designed for a live load of 20.Opsf on the bottom chord in all area I s where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 4) Refer to girder(s) for truss to truss connections. 5) Provide mechanical connection (by others) of truss to bearing plate capable of withstaiding 100 lb uplift at joint(s) 3 except at=lb) 2=333. 1 Walter P. Finn PE No.22839 MiTek USA, Inc. FL Cart 6634 6904 Parke East Blvd. Tampa Fl. 33610 Date; November 12,2018 ,& WARNING - Verify design parameters and READ NOTES ON THIS AND iNcLuDED mrTEK REFERANCEPAGEMII-7473 rev. 10/0.WOIS BEFORE USE. Design valid for use onlywith Mrrek@ connectors. This design Is based only upon parameters shown, and Is for an individual building component, not a truss system. Before use, the building designer must verity the applicability of design parameters and properly Incorporate this design Into the overall building design. Bracing Indicated Is to prevent buckling of Individual truss web and/or chord members only, Additional temporary and permanent bracing MiTek' Is always required for stability and to prevent collapse with possible personal Injury and property domdge. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, seeANSUVII Quallty Cifferla, DSB-89 and IICSI Belding Component 6904 Parke East Blvd., Safety [riformationavalloble from Truss Plate Institute, 218 N. Lee Street, Suite 312, AJexandria, VA 2231 Tampa, FL 33610 Job Truss Truss Type Qty Ply ACQUAVISTA . T15560602 75575 JB Jack -Open 1 Job Reference (optional) Uhambers I russ, Inc., t-on vierce, t-L ij.l;iu a mar i i zui b mi i eK inausines, inc. ivion iNov i z u'd:ou; i to eu i a rage I ID:aNkrWfLwRDXTOZhc4Bay—yKyKq-soOnGbDZkVvutruTh7mzitxJTUt53PCAwRmV9OyJz7M 2 6.00 T 6 3 3x4 = �---4-O ch Scale = 1:9.4 LOADING (pso SPACING- 2;0-0 CS1. DEFL. in (loc) I/defl Ud PLATES GRIP TCLL 20.0 Plate Grip DOL .25 TC 0.19 Vert(LL) -0.00 6 >999 360 MT20 244/190 TCDL 15.0 Lumber DOL 1.25 BC 0.22 Vert(CT) -0.00 6 >999 240 BCLL 0.0 Rep Stress Incr YES WB 0.00 Horz(CT) -0.00 2 n/a n1a BCDL 10.0 Code FBC2017ITP12014 Matrix -MP Wind(LL) 0.01 3-6 >999 240 Weight: 7 lb FT = 20% LIUMBER- TOP CHORD 2x4 SP No.3 BOT CHORD 2x4 SP No.3 REACTIONS. (lb/size) 1=102/0-8-0,2=66/Mechanical,.3=36/MechanicaI Max Harz 1=87(LC 12) Max Uplift 1=-68(LC 12), 2=-85(LC 12), 3=-22(LC 12) Max Grav 1 =1 07(LC 17), 2=75(LC 17), 3=44(LC 3) FORCES. (lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. NOTES- 1) Wind: ASCE 7-10;.Vult=170mph (3-second gust) Vasd=132mph; TCDL=4.2psf; BCDL 11; Exp D; Encl., -GCpi=O. 18; MWFRS (directional) and C-C Exterior(2) zone;C-C for m shown; Lumber DOL=1.60 plate grip DOL=1.60 2) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with 3) * This truss has been designed for a live load of 20.Opsf on the bottom chord in all are will fit between the bottom chord and any other members. 4) Refer to girder(s) for truss to truss connections. 5) Provide mechanical connection (by others) of truss to bearing plate capable of withsta BRACING- TOPCHORD Structural wood sheathing directly applied or 2-4-0 oc purlins. BOTCHORD Rigid ceiling directly applied or 10-0-0 oc bracing. :; h=33ft; B=53ft; L=65ft; eave=7ft; Cat. and forces & MWFRS for reactions ty other live loads. where a rectangle 3-6-0 tall by 2-0-0 wide 100 lb uplift at joint(s) 1, 2, 3. Walter P. Finn PE No.22839 MiTek USA, lhe. FL Carl 6634, 6904 Parke East Blvd. Tampa FL 33,610 Date' November 12,2018 ,& WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MffEKREFERANCEPAGEMII-7473 rev. 10103*015 BEFORE USE. Design valid for use only with MITek@ connectors. This design Is based only upon parameters shown, and is for an Individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters andproperly incorporate this design Into the overall building design. Bracing Indicated Is to prevent buckling of Individual truss web and/or chord members only. Additional temporary and permanent bracing Is always required for stability and to prevent collapse with possible personal Injury and property damage. For general guidance regarding the , MiTek' fabrication, storage, delivery, erection and bracing of trusses and truss systems, seeANSVIPII Quality Cifieft, DSB-89 and SCSI Building Component 6904 Parke East Blvd. Safety Informationavollable from Truss Plate Institute, 218 N. Lee Street Suite 312, Alexandria, VA 22314J, Tampa, FL 33610 Job Truss Truss Type Qty Ply ACQUAVIS TA I T15560603 75575 Jul JACK -OPEN 2 � Job Re Uhambers I russ, Inc., i-ort merce, 1--l- ADEQUATE SUPPORT REQUIRED. b.izju a mar ii zuib mi ieK inausines, Inc. man Nov i;d uu:du:zu zvib rage i ID:aNkrWfLwRDXTOZhc4Bay—yKyKq-K_x9TxEBVpl IU_TfEqHCF5UTyuAPorSJ85V2hqyJz7L -1-6-0 i 1-0-0 3 Fl —2 . -- . y 2 7 CP '7 6 3.5 LOADING (ps� SPACING- 2-0 CSI DEFL. in (loc) I/defl Ud TCLL 20.0 Plate Grip DOL 1 5 .�O TC 0.21 Vert(LL) , -0.00 5 >999 360 TCDL 1 5.0 Lumber DOL 1.25 BC 0.35 Vert(CT) -0.00 5 >999 240 13CLL 0.0 Rep Stress Incr YES WB 0.00 Horz(CT) -0.00 1 n/a n/a BCDL 10.0 Code FBC2017fTP]2014 Matrix -MP Wind(U-) 0.00 5 >999 240 LUIMEIER- TOP CHORD 2x4 SP No.3 BOT CHORD 2x4 SP No.3 REACTIONS. (lb/size) 1=68/Mechanical,3=-O/Mechanical,4=166/MechanicaI Max Harz 3=266(LC 17), 4=-284(LC 17) Max Uplift 1=-65(LC 12), 4=-1 17(LC 12) Max Grav 1=76(LC 17), 4=178(LC 17) FORCES. (lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOPCHORD 2-3=-304/261 BOTCHORD 2-4=-345/498 NOTES- 1) Wind: ASCE 7-10; Vult=170mph (3-second gust) Vasd=132mph; TCDL=4.2psf; BCDLI 11; Exp D; Encl., GCpi=0.18; MWFRS (directional) and C-C Exterior(2) zone; cantilever forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 1 2) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with , 3) * This truss has been designed for a live load of 20.Opsf on the bottom chord in all area will fit between the bottom chord and any other members. 4) Refer to girder(s) for truss to truss connections. 5) Provide mechanical connection (by others) of truss to bearing plate capable of withstan 4=1 17. Scale = 1:9.7 PLATES GRIP MT20 244/190 Weight: 6 lb FT = 20% BRACING - TOP CHORD Structural wood sheathing directly applied or 1 -0-0 oc purlins. BOTCHORD Rigid ceiling directly applied or 6-0-0 oc bracing. )psf; h=33ft; B=53ft; L=65ft; eave=7ft; Cat. and right exposed ;C-C for members and iy other live loads. where a rectangle 3-6-0 tall by 2-0-0 wide 100 lb uplift at joint(s) 1 except at=lb) Walter P. Finn PE No.22839 MiTek USA, Inc. Fl. Cori 6634. 6904 Parke East Blvd. Tampa FIL 33610 Date: November 12,2018 ,& WARNING - Verify design parameters and READ NOTES ON THISAND INcLuDED mrrEKREFERANCEPAGE M11-7473 re, 1W=015BEFORE USE. Design valid for use only with MITek@ connectors. This design Is based only upon parameters shown, and Is for an individual building component, not a truss system. Before use, the building designer must verify the cibpllcoblllty of design parameters and 1properly Incorporate this design Into the overall building design. Bracing indicated Is to prevent buckling of Individual truss web and/or chord members only. AddItional temporary and permanent bracing MiTek* Is always required for stability and to prevent collapse with possible personal Injury and property damage. For general guidance regarding the fabrication, storage, delivery, erectlon and bracing of trusses and truss systems, seeANSVIP11 Quality Criteria, DSB-89 and BCSI Building Component 6904 Parke East Blvd. Solely Informationovallable from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 223141 Tampa, FL 33610 Job Tru s Truss Type Qty Ply AC QUAVISTA T15560604 � 75575 JU3 JACK -OPEN 1 1 Job Reference (optional) L;namDers I russ, Inc., i--orr rierce, �-!_ ADEQLIj SUPPOF REQUIR ts.iju s mar 11 zui ts mi I eK inaustries, Inc. man NOV I Z UV:JV:ZU ZU1 d vage i ID:aNkrWfLwRD)CrOZhc4Bay—yKyKq-K-x9TxEBVp1 IU-TfEqHCF5URTuCcoqZJ85V2hqyJz7L I1 1.40-06 1. LOADING (psf) SPACING- 2-0-0 CS1. DEFL. in (loc) I/clefl Lid TCLL 20. 0 ate Grip DOL Ple 1.25 TC 0.36 Vert(LL) -0.00 7 >999 360 TCDL 15 .0 Lumber DOL 1.25 BC 0.21 Vert(CT) -0.01 7 >999 240 BCLL 0.0 Rep Stress Incr YES WB 0.12 Horz(CT) -0.01 5 n1a n/a BCDIL 10.0 Code FBC2017/TP12014 Matrix -MP Wind(LL) 0.02 7 >999 240 LUIMEIER- TOP CHORD 2X4 SP NO.3 BOT CHORD 2x4 SP No.3 WEBS 2x4 SP No.3 Scale = 1:13.9 PLATES GRIP MT20 244/190 Weight: 13 lb FT �_ 20% BRACING - TOP CHORD Structural wood sheathing directly applied or 3-0-0 oc purlins. BOTCHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS. All bearings Mechanical except at=length) 6=0-8-0. (lb) - Max Harz 1 =1 67(LC 12) MaxUplift All uplift 100 lb or less atjoint(s) 1, 4, 5 except 6=-298(LC 12) Max Grav All reactions 250 lb or less at joint(s) 1, 4, 5 UAUUPL 17) FORCES. (lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. WEBS 3-6=-249/41 0 NOTES- 1) Wind: ASCE 7-10; Vult=170mph (3-second gust) Vasd=132mph; TCDL=4.2psf; BCDL 11; Exp D; Encl., GCpi=0.18; MWFRS (directional) and C-C Extetior(2) zone; cantilever MWFRS for reactions shown; Lumber DOL=1.60 plate gdp DOL=1 �60 2) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with 3) * This truss has been designed for a live load of 20.Opsf on the bottom chord in all are, will fit between the bottom chord and any other members. 4) Refer to girder(s) for truss to truss connections. 5) Provide mechanical connection (by others) of truss to bearing plate capable of withstar at=lb) 6=298. )psf; h=33ft; B=53ft; L=65ft; eave=7ft; Cat. exposed ;C-C for members and forces & iy other live loads. where a rectangle 3-6-0 tall by 2-0-0 wide 100 Ito uplift at joint(s) 1, 4, 5 except Walter P. Finn PE No.22839 MiTek USA, Inc. Fl. Cart 6634 69D4 Parke East Blvd. Tampa Fl. 336 , 10, Date: November 12,2018 AL WARNING -Verity design parameters and READ NOTES ON THIS AND INCLUDED MITEKREFERANCE PAGE M11-7473 rev. la1=015 BEFORE USE. Design valid for use only with lVIITek@ connectors. This design Is based only upon parameters shown, and Is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly Incorporate this design Into the overall building design. Bracing Indicated Is to prevent buckling of Individual truss web and/or chord members only. Additional temporary and permanent bracing M!Tek* Is always required for stability and to prevent collapse with possible personal Injury and property clam�ge. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, seeANSUTPI1 Quality Criteria, DSB-89 and BCSI Building Componant 6904 Parke East Blvd. Safelly Informatlanovallable from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22310. Tampa, FL 33610 Job Truss Truss Type I Qty Ply ACQUAVISTA T15560605 75575 K Common 4 Job Reference (optional) L,namoers I russ, Inc.,. ran rierce, M 0. IOUs MIR 1 1 eu I a IVII I UK H IuUbL1 [Uzi, IT IL;. IVIUI I 1MUV 14 UV;OV;4I ev I a ruyu I ID:aNkrWfLwRDXTOZhc4Bay—yKyKq-oBVYhHFpG69c681 soYoRn[04ylVtXGsTNIFcEGyJz7K 3X4 = 27.0 6 3x4 = 1 3XB 11 .0 LOADING (psf) SPACING- 2-0-0 CSI. DEFL. in (loc) I/defl Ud TCLL 20.0 Plate Grip DOL 1.25 TIC 0.57 Vert(LL) -0.06 7-14 >999 360 TCDL 1 5.0 Lumber DOL 1.25 BC 0.40 Vert(CT) -0.13 7-14 >999 240 BCLL 0.0 Rep Stress Incr . YES WB 0.18 Horz(CT) 0.62 6 n/a n1a BCDL 10.0 Code FBC2017rrP]2014 Matrix -MS Wind(LL) 0.13 7-10 >999 240 LIUMBER- TOP CHORD 2X4 SP M 30 BOT CHORD 2X4 SP M 30 WEBS 2x4 SP No.3 SLIDER Right 2x4 SP No.3 2-6-0 REACTIONS. (lb/size) 6=681 /Mechanical, 2=796/0-8-0 Max Horz 2=1 98(LC 11) Max Uplift 6=-577(LC 12), 2=-790(LC 12) FORCES. (lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOPCHORD 2-3=-1360/1609, 3-4=-1034/1211, 4-6=-992/1172 BOTCHORD 2-7=-1408/1228, 6-7=-857/839 WEBS 3-7=-452/608, 4-7=-303/413 NOTES- 1 ) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-10; Vult=170mph (3-second gust) Vasd=132mph; TCDL--4.2psf; BCD1 11; Exp D; Encl., GCpi=O.l 8; MWFRS (directional) and C-C Exteflor(2) -1-6-0 to 4-11-1 to 14-9-2 zone;C-C for members and forces & MWFRS for reactions shown; Lumber 1 3) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with 4) * This truss has been designed for a live load of 20.Opsf on the bottom chord in all are will fit between the bottom chord and any other members. 5) Refer to girder(s) for truss to truss connections. 6) Provide mechanical connection (by others) of truss to bearing plate capable of withsta 6=577,2=790. PLATES GRIP MT20 244/190 Weight: 64 lb FT = 20% BRACING - TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc puffins. BOTCHORD Rigid ceiling directly applied or 6-0-14 oc bracing. 3.Opsf; h=33ft; B=53ft; L=65ft; eave=7ft; Cat. Interior(l) 4-11-13 to 8-1 -0, Exterior(2) 8-1 -0 )L=1.60 plate grip DOL=1.60 ny other live loads. ; where a rectangle 3-6-0 tall by 2-0-0 wide 100 lb uplift at joint(s) except at=lb) Walter P. Finn.PE No.22839 MiTek USA, Inc. FL Cert 6634 6904 Parke East Blvd. Tampa FL 33610 DaW. November 12,2018 ,& WARNING - Verity design parameters and REA D NOTES ON THIS AND INCLUDED MfTEK REFERANCE PAGE M11-7473 rev. 1010312015 BEFORE USE. Design valid for use only with MITek@ connectors. This design Is based only upon parameters shown ond is for an individual building component, not the the �n� a truss system. Before use, building designer must verity applicability of design parameters properly Incorporate this design Into the overall building design. Bracing Indicated Is to prevent buckling of Individual truss web and/or chord members only. Additional temporary and permanent bracing M!Tek' Is always required for stability and to prevent collapse with possible personal Injury and property dom6ge. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, seeANSVrPI1 Quality Cittarla, DSB-89 and I3CS1 Building Componant 6904 Parke East Blvd. Safally Informationcivallable from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314. Tampa, FL 33610 Job Truss Truss Type City Ply7AI QUAVISTA T15560606 75575 K1 Half Hip 2 1 1 J jot ob Reference (optional) Chambers Truss, Inc., Fort Pierce, FL 5.00 F12 2X3 -Z�, 3 13 3x5 = 8.130 s Mar 11 2018 MiTek Industries, Inc. Mon Nov 12 09:39:22 2018 Page I ID:aNkrWfLwRDXTOZhc4Bay—yKyKq-GN3wudFRIQHTkic2MFJgKWZmqir8GYxccP-9miyJz7J 9-0-0 15-6-0 6-6-0 4x6 5x8 4 53X6 3x8 = 3X4 11 Scale = 1:29.4 1 9-0-0 6-6-0 Plate Offsets (X,Y)-- [2:0-0-6,Edgel, [5:0-1-8,0-3-01 LOADING (psf) SPACING- 2-0-0 CS1. DEFL. in (loc) I/def] Ud PLATES GRIP TCLL 20.0 Plate Grip DOL 1.25 TC 0.44 Vert(LL) -0.11 7-11 >999 360 MT20 .244/190 TCDL 15.0 Lumber DOL 1.25 BC 0.39 Vert(CT) -0.26 7-11 >720 240 BCLL 0.0 Rep Stress Incr YES WB 0.83 Horz(CT) -0.02 12 n/a n/a BCDL 10.0 Code FBC2017[TP12014 Matdx-MS Wind(LL) 0.12 7-11 >999 240 Weight: 80 lb FT = 20% LUMBER - TOP CHORD 2X4 SP M 30 BOT CHORD 2X4 SP M 30 WEBS 2x4 SP No.3 OTHERS 2x4 SP No.3 REACTIONS. (lb/size) 2=801/0-8-0,12=660/0-3-8 Max Horz 2=429(LC 12) Max Uplift 2=-751(LC 12), 12=-601(LC 12) Max Grav 2=825(LC 17),12=660(LC 1) FORCES. (lb) - Max. Comp./Max. Ten. - All forces 260 (lb) or less except when shown. TOPCHORD 2-3=-1 195/1265, 3-4=-836/861, 4-5=-763/861 BOT CHORD 2-7=-1487/1170 WEBS 3-7=-488/746, 5-7=-906/804, 5-12=-677/765 BRACING- TOPCHORD Structural wood sheathing directly applied or 6-0-0 oc puffins, except end verticals. BOTCHORD Rigid ceiling directly applied or 5-9-13 oc bracing. NOTES- 1) Wind: ASCE 7-10; Vult=l 70mph (3-second gust) Vasd=1 32mph; TC DL=4.2psf; BCDLi3.Opsf; h=33ft; B=53ft; L=65ft; eave=7ft; Cat. 11; Exp D; Encl., GCpi=0.18; MWFRS,(directional) and C-C Exterior(2) -1-6-0 to 4-11-1�1' Interior(l) 4-11-13 to 9-0-0, Exterior(2) 9-0-0 to 15-0-12 zone;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 2) Provide adequate drainage to prevent water ponding. I : 3) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent With any other live loads. 4) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 1 5) Bearing at joint(s) 12 considers parallel to grain value using ANSIrrP1 1 angle to grain formula. Building designer should verify capacity of bearing surface. 6) Provide mechanical connection (by others) of truss to bearing plate capable of withstan d1ing 100 lb uplift at joint(s) except at=lb) 2=751,12=601. 1 Walter P. Finn PE NoM39 MiTak USA, In'c. FL Cart 6634 691114 Parke East Blvd. Tampa FL 3361 , 0 Date� November 12,2018 WARNING -Verify design parameters and READ NOTES ON THIS AND INCLUDED MrrEKREFERANCE PAGE MIJL7473 rev. 1WO3,2015 BEFORE USE. Design valid for use only with IvIITek@ connectors. This design Is based only upon parameters shown, and Is for an Individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly Incorporate this design Into the overall building design. Bracing Indicated Is to prevent buckling of Individual truss web and/or chord members only. Additional temporary and permcnentbracIng MiTdk' Is always required for stability and to prevent collapse with possible personal Injury and property dam6ge. For general guidance regarding the . fabrication, storage, delivery; erection and bracing of trusses and truss systems, seeANSVTPII Quality Cdteda. DSIII-69 and BCSI Bufldtng Component 6904 Parke East Blvd. Safety Informationovallable from Truss Plate Institute, 218 N. Lee Street Suite 312, Alexandria, VA 22314. . Tampa, FL 33610 Job Truss Truss Type Qty Ply ACQUAVISTA T15560607 75575 K2 Halt Hip 1 Job Reference (optional) Chambers Truss, Inc., Fort Pierce, FL 8.130 s Mar 11 2018 MiTek Industries, Inc. Mon Nov 12 09:39:22 20118 Page I imirouduccr-9miyaLM Scale = 1:33.0 5.00F12 16 5x6 i:�- r--11 L I 14 2 F E 13 1� � 4 1 r4. L- In, 6 6 H 8 7 3x5 7-8-4 2x3 11 3x8 3x4 11 15-6-0 7-8-4 4-6-0 Plate Offsets (X,Y)-- [2:0-1-2,Edgel, [5:0-1-8,0-3-01 LOADING (psf) SPACING- 2-0-0 CS1. DEFL. in (loc) I/defi Ud PLATES GRIP TCLL 20.0 Plate Grip DOL 1.25 TC 0.60 Vert(LL) -0.07 8-12 >999 360 MT20 244/190 TCDL 15.0 Lumber DOL 1.25 BC 0.44 Vert(CT) -0.19 B-12 >971 240 BCLL 0.6 Rep Stress Incr YES WB 0.55 Horz(CT) -0.02 13 n/a n/a BCDL 10.0 Code FBC2017[TP12014 Matrlx-MS Wind(LL) 0.18 8-12 >999 240 Weight: 88 lb FT = 20% LIUMBER- TOP CHORD 2X4 SP M 30 BOTCHORD 2X4 SP M 30 WEBS 2x4 SP No.3 OTHERS 2x4 SP'No.3 REACTIONS. (lb/size) 2=801/0-8-0,13=660/0-3-8 Max Harz 2=505(LC 12) Max Uplift 2=-730(LC 12),13=-622(LC 12) Max Grav 2=832(LC 17),13=675(LC 17) FORCES. (lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 2-3=-1 132/1049, 3-4---576/608, 4-5=-488/588 BOTCHORD 2-8=-1 334/1071, 7-8�--1 334/1071 WEBS 3-8=-85/291, 3-7=-800/1022, 5-7=-803/662, 5-13=-698/811 NOTES- 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-10; Vult=170mph (3-second gust) Vasd=132mph; TCDL=4.2psf; BCDL 11; Exp D; Encl., GCpi=0.18; MWIF * RS (directional) and C-C Exterior(2) -1-6-0 to 4-11 -1 11 -0-0 to 15-0-12 zone;C-C for members and forces & MWFRS for reactions shown; L 3) Provide adequate drainage to prevent water ponding. 4) This truss has been designed for a 10.0 lost bottom chord live load nonconcurrent with 5) * This truss has been designed for a live load of 20.Opsf on the bottom chord in all are� will fit between the bottom chord and any other members. 6) Bearing at joint(s) 13 considers parallel to grain value using ANSI/TPI 1 angle to grain capacity of bearing surface. 7) Provide mechanical connection (by others) of truss to bearing plate capable of withstai 2=730,13=699. BRACING- TOPCHORD Structural wood sheathing directly applied or 6-0-0 oc purlins, except end verticals. BOTCHORD Rigid ceiling directly applied or 5-5-13 oc bracing. i.Opsf; h=33ft; B=53ft; L=65ft; eave=7ft' Cat. Inteflor(l) 4-11-13 to I 1 -0-0, Exterior(�) nber DOL=1.60 plate grip DOL=1.60 iy other live loads. where a rectangle 3-6-0 tall by 2-0-0 wide Building designer should verify 100 lb uplift at joint(s) except Gt=lb) Walter P. Finn PE No.22839 MiTek USA, Inc. FL Cart 6634. 6904 Parke East Blvd. Tampa FL 33610 Date' November 12,2018 wAnNiNa - verify design parameters and READ NOTES ON THIS AND INCLUDED MITEKREFERANCE PAGE MIP7473 rev. 1010=015 BEFORE USE. Design valid for use only with MITek@ connectors. This design Is based only upon parameters shown, a , nd li for an Individual building component not a truss system. Before use, the building designer must verify the applicability of design parameters and properly Incorporate this design Into the overall building design. Bracing Indicated Is to prevent buckling of Individual truss web and/or chord members only. Additional temporary and permanent bracing MiTek' Is always required for stability and to prevent collapse with possible personal Injury and property dambgg. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems. seeANSYWII Quality CrItaft, D513-89 and BCSI Building Component 6904 Parke East Blvd. Safaty Infounationavollable from Truss Plate Institute, 218 N. Lee Street Suite 312, Alexandria, VA 22314. Tampa, FIL 33610 Job Truss Truss Type , . Qty . Ply ACQUAVISTA I T15560608 75575 KJ3 Diagonal Hip Girder 2 1 Job Reference (optional) L;namDers iniss, Inc., von merce, t-L b.i;ju a mar i i zult3 mi i eK inouslines, Inc. man NOV 1Z UU:dU:Zd ZUItS t-age i ID:aNkrWfLwRDXTOZhc4Bay—yKyKq-kZdl6zG3nkPKLSBEwzrvsi6zT6Ec?CBmq3kil9yJz7I -2-1-7 4-2-3 2-1-7 4-2-3 Scale: 1"=1' 3 FA 2 1 3x4 = r1_2 NAILED NAILED 8� 9 NAILED NAILED LOADING (psf) SPACING- 2-0-0 CS1. DEFL. in (loc) I/defl Ud TCLL 20.0 Plate Grip DOL 1.25 TC 0.32 Vert(LL) -0.07 4-7 >756 240 TCDL 15.0 Lumber DOL 1.25 BC 0.25 Vert(CT) -0.06 4-7 >786 180 BCLL 0.0 Rep Stress Incr NO WB 0.00 Horz(CT) 0.00 2 n/a n/a BCDL 10.0 Code FBC2017fTP12014 Matrix -MP LUMIBER- TOP CHORD 2X4 SP M 30 BOTCHORD 2X4 SP M 30 REACTIONS. (lb/size) 3=75/Mechanical, 2=270/0-10-15, 4=13/Mechanical Max Harz 2=1 96(LC 8) Max Uplift 3=-1 11 (LC 8), 2=-493(LC 8), 4=-1 5(LC 17) Max Grew 3=94(LC 28), 2--307(LC 28), 4=98(LC 24) FORCES. (lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. NOTES- 1) Wind: ASCE 7-10; Vult=170mph (3-second gust) Vasd=132mph; TCDL=4.2psf; BCDL 11; Exp D; Ehcl.,,GCpi=0.18; MWFRS (directional); Lumber DOL=1.60 plate grip DOL—_ 2) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with 3) * This truss has been designed for a live load of 20.Opsf on the bottom chord in all arez will fit between the bottom chord and any other members. 4) Refer to girder(s) for truss to truss connections. 5) Provide mechanical connection (by others) of truss to bearing plate capable of withstar 3=111,2=493. 6) "NAILED" indicates 3-1.0d (0.1 48"x3") or 2-112d (0.1 48"x3l.25") toe -nails per NDS guidlii 7) In the LOAD CASE(S) section, loads applied to the face of the truss are noted as front LOAD CASE(S) Standard 1) Dead + Roof Live (balanced): Lumber Increase=1.25, Plate lncrease=1.25 Uniform Loads (plf) Vert: 1-3=-70, 4-5=-20 Concentrated Loads (lb) Vert: 8=8�(F=44, 13=44) 9=72(F=36, B=36) 4 PLATES GRIP MT20 244/190 Weight: 16 lb FT = 20% BRACING- TOPCHORD Structural wood sheathing directly applied or 4-2-3 oc puflins. BOTCHORD Rigid ceiling directly applied or 10-0-0 oc bracing. h=33ft; B=53ft; L=65ft; eave=7ft; Cat. iy other live loads. where a rectangle 3-6-0 tall by 2-0-0 wide 100 lb uplift at joint(s) 4 except at=lb) or back (B). Walter P. Finn PE No.22839, MiTak USA, Inc. Fl. Cott 6634 6904 Parke East Blvd. Tampa FIL 33610 Date: November 12,2018 ,& WARNING - Verify design pararnefrs andREAD NOTES ON THIS AND INCLUDED MITEKREFERANCE PAC';E 11111-7473 rev. I&OX2015BEFORE USE. Design voild,for use only with IVIITek@ connectors. This design Is based only upon parameters shown, and Is for an Individual building component not a truss system. Before use, the building designer must verify the applicability of design parameters and �roperly incorporate this design Into the overall building design. Bracing Indicated Is to prevent buckling of Individual truss web and/or chord members only. Additional temporary and permanent bracing M!Tek' is always required for stability and to prevent collapse with possible personal Injury and property damobe, For general guidance regarding the fabrication, storage, delivery, erectlon and bracing of trusses and truss systems, seeANSVTPII Quality Cifforla, DSB-89 and 111101 Building Component Safety Informatlanavallable from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.1 6904 Parke East Blvd. Tampa, FL 33610 Job Tru s Truss Type . I Qty Ply ACQU AVI] TA T15560609 75575 KJ5 Diagonal Hip Girder 1 1 Job Refen Chambers Truss, inc., Fori Pierce, FL 8J30 5 iviui 11 4010 IVII I eK H IUMMUS, 101C. ­05 140V 1C UV:QV:C" 40 10 rage 1 ID:aNkrWfLwRD)CrOZhc4Bay—yKyKq-CmBgJdHhYlXBzcmRTgMBPxe57VYKkfRv3jTGqbyJz7H -2-1-7 3-9-9 7-0-2 2-1-7 3-9-9 3-2-8 Scale= 1: 17.6 NAILED 3.5 .. 4 F1 _2 NAILED 9 NAILED C� NAILED 9 8 CU 2 4 NAILED NAILED NAILED NAILED 3x4 7-0-2 7-0-2 Plate Offsets (X,Y)-- [2:0-1-4,Edgel LOADING (pso SPACING- 2-0-0 CSI. DEFL. in (loc) I/defl Ud PLATES GRIP TCLL 20.0 Plate Grip DOL 1.25 TC 0.45 Vert(LL) 0.26 4-7 >325 240 MT20 244/190 TCDL 15.0 Lumber DOL 1.25 BC 0.35 Vert(CT) 0.25 4-7 >339 180 BCLL 0.0 Rep Stress Incr NO WB 0.00 HOrz(CT) -0.00 3 n/a n/a BCDIL 10.0 Code FBC2017[rPI2014 Matrix -MP Weight: 25 lb FT = 20% LIUMBER- TOP CHORD 2x4 SP M 30 BOT CHORD 2X4 SP M 30 REACTIONS. (lb/size) 3=186/Mechanical,2=361/0-10-15,4--75/MechanicaI Max Horz 2=272(LC 8) Max Uplift 3=-256(LC 8), 2=-624(LC 8), 4---104(LC 5) Max Grav 3=1 88(LC 28), 2=413(LC 28), 4--113(LC 3) FORCES. (lb) -Max. Comp./Max. Ten. -All forces 250 (lb) or less except when shown. NOTES- 1) Wind: ASCE 7-10; Vult=170mph (3-second gust) Vasd=132mph; T(3DL=4.2psf; BCDLj3 11; Exp D; Encl., GCpi=0.18; MWFRS (directional); Lumber DOL=1.60 plate grip DOL=1 1E 2) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with an 3) * This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas will fit between the bottom chord and any other members. 4) Refer to girder(s) for truss to truss connections. 5) Provide mechanical connection (by others) of truss to bearing plate capable of withstandi 3=256,2=624,4=104. 1 6) "NAILED" indicates 3-10d (0.148"x3") or 2-12d (0.148"x3.25") toe -nails per NDS guiclline� 7) In the LOAD CASE(S) section, loads applied to the face of the truss are noted as front (IF LOAD CASE(S) Standard 1) Dead + Roof Live (balanced): Lumber Increase=1.25, Plate Increase=1.25 Uniform Loads (plf) Vert: 1-3=-70, 4-5=-20 Concentrated Loads (lb) Vert: 8=86(F=44, B=44) I 0=72(F=36, B=36) 11 =-8(F=-4, B=-4) BRACING - TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc puffins. BOTCHORD Rigid ceiling directly appliedo.r 10-0-0 oc bracing. h=33ft; B=53ft; L=65ft; eave=7ft; Cat. y other live loads. where a rectangle 3-6-0 tall by 2-0-0 wide 100 lb uplift at joint(s) except at=lb) or back (B). Walter P. Finn PE No.22839 MiTek USA, Inc. FL Cert 6634 6904 Parke East Blvd. Tampa FL 33.810 Date: November 12,2018 ,&WARNING -Verity design parameters and READ NOTES ON THIS AND INCLUDED MITEKREFERANCE PAGE 11111-7473 rev. 1WO312015 BEFORE USE. Design valid for use only with MITek@ connectors. This design Is bosed.only upon parameters shown, and Is for an Individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and broperly Incorporate this design Into the overall building design. Bracing Indicated Is to prevent buckling of Individual truss web and/or chord member� only. Additional temporary and permanent bracing M!Tek' Is always required for stability and to prevent collapse with possible personal Injury and property damage. For general guidance regarding the . fabrication, storage, delivery, erectIon and bracing of trusses and truss systems, seeANSVWII QUOUty Crttedo, DSB-89 and BCSI Building Component Safety Informictlonovallable from Truss Plate Institute, 218 N. Lee Street Suite 312, Alexandria, VA 22314.1 6904 Parke East Blvd. Tampa, FL 33610 Job T s Truss Type City Ply ACQUAVITA I T1 5560610 75575 KJ7 DIAGONAL HIP GIRDER 1 9 1 Job Reference (optional) Chambers Truss, Inc., Fort Pierce, FL 8.130 a Mar 11 2018 MiTek Industries, Inc. Mon Nov 12 09:39:25 2018 Page 1 ID:aNkrWfLwRDXTOZhc4Bay—yKy�<q-gyl2XfIJJLf2bmLdlOtNy8Bl7vvGT?L3]NDpNlyJz7G Scale = 1:22.6 17 C� C 'R M C� 5-8-3 5-8-3 1 9-10-1 4-1-14 Plate Offsets (X,Y)-- [2:0-1-4,Edgel LOADING (psf) SPACING- 2-0-0 CS1. DEFL. in (loc) I/defl Ud PLATES GRIP TCLL 20.0 Plate Grip DOL 1.25 TC 0.37 Vert(LL) 0.10 6-7 >999 240 MT20 244/190 TCDL 15.0 Lumber DOL 1.25 BC 0.31 Vert(CT) -0.05 6-7 >999 240 BCLL 0.0 Rep Stress Incr NO WB 0.47 Horz(CT) -0.02 5 We n/a BCDL 10.0 Code FBC2017/TP12014 Matrix -MS Weight: 41 lb FT = 20% LUMBER - TOP CHORD 2X4 SP M 30 BOT CHORD 2X4 SP M 30 WEBS 2x4 SP No.3 REACTIONS. (lb/size) 4--140/Mechanical, 2=516/0-10-15,5=379/Mechanical Max Horz 2=348(LC 8) Max Uplift 4=-1 93(LC 8), 2=-11 023(LC 8), 5=-716(LC 8) FORCES. (lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 2-3=-834/1345 BOTCHORD 2-7=;-1444t779, 6-7=-1444t779 WEBS 3-7=-4621267, 3-6=-852/1579 BRACING - TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins. BOT CHORD Rigid ceiling directly applied or 5-9-3 oc bracing. NOTES- 1) Wind: ASCE 7-10; Vult=170mph (3-second gust) Vasd=132mph; TCDL--4.2psfl- BCDL--13.Opsf; h=33ft; B=53ft; L=65ft; eave=7ft; Cat. 11; Exp D; Encl., GCpi=0.18; MWFRS (directional); porch left and right exposed; LumberlDOL=1.60 plate grip DOL=1.60 2) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with a I hy other live loads. 3) * This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 4) Refer to girder(s) for truss to truss connections. 1 1 5) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) except at=lb) 4=193,2=1023,5=716. 1 6) "NAILED".indicates 3-1 Od (0.1 48"x3") or 2-12d (0.1 48"x3.25") toe -nails per NDS guidline,-. 7) In the, LOAD CASE(S) section, loads applied to the face of the truss are noted as front (F) or back (B). LOAD CASE(S) Standard 1) Dead + Roof Live (balanced): Lumber lncrease=1.25, Plate increase=1.25 Uniform Loads (plf) Vert: 1-4=-70, 5-8=-20 Concentrated Loads (lb) Vert: 11 =88(F=44, B=44) 13=-88(F=-44, B=-44) 14--72(F=36, B=36) 15=- B(F=-4 'I B=-4) 16=-70(Fm-35, B=-35) Walter P. Finn PE No.22839 M!TekUSA, Inc. FL Cert 6634. 6904 PMWEast Blvd. Tampa FL 33610 Date: November 12,2018 wARNiNr - Verify design parameters and READ NOTES ON THIS AND INCLUDED MnEK REFERANCE PAG I E M11-7473 rev, 10103(2015 BEFORE USE. Design valid for use only with MITek0 connectors, This design Is based only upon parameters shown, and Is for an Individual building component not a truss system. Before use. the building designer must verify the applIcabIlity of design parameters and l5roperly Incorporate this design Into the overall building design, Bracing Indicated Is to prevent buckling of Individual truss web and/or chord members only. Additional temporary and permanent bracing MiTek" Is always required for stability and to prevent collapse with possible personal Injury and property damage. For general guidance regarding the . fabrication, storage, delivery, erection and bracing of trusses and truss systems, seeANSYT113111 Quality Criteria, DSB-89 and BCSI Bulding Component SOfGty Informatlanovallable from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.1 6904 Parke East Blvd. Tampa, FIL 33610 Job Tru s Truss Type y ACQUAVISTA T15560611 75575 KJA Diagonal Hip Girder 1 Job Reference (optional) U1141flUdIb I Wbb, IFIU., run rimue, rL 2 0 Plate Offsets (X,Y)-- ti.lou s mar ii zuits mi ieK inausines, Inc. man NOV 12 U9:392tj ZUlb vage i ID:aNkrWfLwRDXTOZhc4Bay—yKyKq-BBJQK-ly4fnuDvwpb5OcUMkUjJFpCZXCX1 yNvUyJz7F 3-2-14 3-2-14 Scale = 1:10.6 3 NAILED 7 3.5 4 1`1� 2 NAILED 8 9 4 NAILED NAILED 3x4 = LOADING (psf) SPACING- 2-0-0 CS1. DEFL. in (loc) Vdefl Ud PLATES GRIP TCLL 20.0 Plate Grip DOL 1.25 TC 0.32 Vert(LL) -0.04 4-7 >999 240 MT20 244/190 TCDL 15.0 Lumber DOL 1.25 BC 0.22 Vlert(CT) 0.02 4-7 >999 240 BCLL 0.0 Rep Stress Incr NO WB 0.00 Horz(CT) 0.00 2 n/a n/a BCDL 10.0 Code FBC2017/TP12014 Matrix -MP Weight: 13 lb FT = 20% LUMBER - TOP CHORD 2X4 SP M 30 BOT CHORD 2X4 SP M 30 REACTIONS. (lb/size) 3=31 /Mechanical, 2=257/0-10-15, 4=-14/Mechanical Max Horz 2=1 71 (LC 24) - Max Uplift 3=-62(LC 8), 2=-482(LC 8), 4---48(LC-1 7) Max Gram 3=77(LC 22), 2=276(LC 28), 4=1 35(LC 24) FORCES. (lb) -Max. Comp./Max. Ten. -All forces 250 (lb) or less except when shown. NOTES- 1) Wind: ASCE 7-10; Vult=170mph (3-second gust) Vasd=132mph; TCDL--4-2psf-, BCDLj, 11; Exp D; Encl., GCpi=0.18; MWFRS (directional); Lumber DOL=1.60 plate grip DOL=1' I 2) Truss designed for wind loads in the plane of the truss only. For studs exposed to wind 1 1( Gable End Details as applicable, or consult qualified building designer as per ANSI/TPI I 3) Gable studs spaced at 2-0-0 oc. 1 4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with an 5) * This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas' will fit between the bottom chord and any other members. 6) Refer to girder(s) for truss to truss connections. 1 7) Provrde mechanical connection (by others) of truss to bearing plate capable of withstand! 2=482. 1 8) "NAILED" indicates 3-1 Od (0. 1 48"x3") or 2-12d (0. 1 48"x3.25") toe -nails per INDS guldline,� 9) In the LOAD CASE(S) section, loads applied to the face of the truss are noted as front (17, LOAD CASE(S) Standard 1) Dead + Roof Live (balanced): Lumber lncrease=l.�5, Plate Increase=1.25 Uniform Loads (plf) Vert: 1-8=-70, 4-5=-20 Concentrated Loads (lb) Vert: 8=88(F=44, 121=44) 9=72(F=36, 13=36) EIRACING7 TOP CHORD Structural wood sheathing directly applied or 3-2-14 oc puffins. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. ; h=33ft; B=53ft; L=65ft; eave=7ft; Cat. to the face), see Standard Industry y other live loads. where a rectangle 3-6-0 tall by 2-0-0 wide 100 lb uplift at joint(s) 3, 4 except at=lb) or back (B). Walter P. Finn FIE No.22839 MiTek USA, Inc. FL Cert 6634. 8904 Parke East Blvd. Tampa FL 33610 Date: November 12,2018 WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEKREFERANCE PAGE' Mll-7473 re. 1010312015 BEFORE USE. I Design valid for use only with IVITek@ connectors. This design is based only upon parameters shown, and Is for an Individual building component not a truss system. Before use, the building designer must verify the applicability of design parameters and �.roperly Incorporate this design Into the overall building design, Bracing Indicated Is to prevent buckling of Individual truss web and/or chord members'only. Additional temporary and permanent bracing M!Tdk' Is always required for stability and to prevent collapse with possible personal Injury and property clarnagg. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, seeANSIMIJ Quality CrItedo, DSO-69 and BCSI Building Component 6904 Parke East Blvd. Safety Informationavallable from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314. 1 Tampa, FL 33610 Job Tru a Truss Type Qty Ply ACQUAVIII TA T15560612 75575 KJB Roof Special Girder Job Reference (optional) Chambers Truss, Inc., Fort Pierce, FIL 8.130 a Mar 11 2018 MiTek Industries, Inc. Mon Nov 12 09:39:26 2018 Page I ID:aNkrWfLwRDXTOZhc4Bay-yKyKq-88JQk-ly4fnuDvwpb5OcUMkpjJHYCZxCXIyNvUyJz7F .2-1-7 2-7-0 2-1-7 2-7-0 3.54F1-2 IF NAILED NAILED 10 NAILED NAILED LOADING (psf) SPACING- 2-0-0, CS11. DEFL. in (loc) I/defI Lid TCLL 20.0 Plate Grip DOL . 1.25 TC 0.32 Vert(LL) -0.01 8 >999 240 TCDL 15.0 Lumber DOL 1.25 BC 0.11 Vert(CT) 0.00 8 >999 240 BCLL 0.0 Rep Stress Incr NO WB 0.00 Horz(CT) 0.00 5 n/a n1a BCDL 10.0 Code FBC2017/TP12014 Matrix -MP LIUMBER- TOPCHORD 2X4 SP M 30 BOT CHORD 2X4 SP M 30 WEBS 2x4 SP No.3 OTHERS 2x4 SP No.3 REACTIONS. (lb/size) 5=-62/0-2-1, 2=282/0-10-15 Max Harz 2=1 43(LC 24) Max Uplift 5=-1 56(LC 17), 2=-491 (LC 8) Max Grav 5=362(LC 24), 2=282(LC 1) FORCES. (lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. 4xB ::� Scale = 1:9.3 I 4 3X4 11 PLATES GRIP MT20 244/190 Weight: 12 lb FT = 20% BRACING- TOPCHORD Structural wood sheathing directly applied or 2-7-0 op purlins, except end verticals. BOTCHORD Rigid ceiling directly applied or 6-0-0 oc bracing. NOTES- I 1) Wind: ASCE 7-10; Vult=1 70mph (3-second gust) Vascl=1 32mph; TCDL=4.2psf; BCDL�3.Opsf; h=33ft; B=53ft; L=65ft; eave=7ft; Cat. 11; Exp D; Encl., GCpi=0.18; MWIFFIS (directional); Lumber DOL=1.60 plate grip DOL=1�60 2) Truss designed for wind loads in the plane of the truss only. For studs exposed to windl(normal to the face), see Standard Industry Gable End Details as applicable, or consult qualified building designer as per ANSI/TPI 3) Gable studs spaced at 2-0-0 oc. 4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with 1� I ny other live loads. 5) * This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 1 6) Bearing at joint(s) 5 considers parallel to grain value using ANSI/TPI 1 angle to grain formula. Building designer should verify capacity of bearing surface. 7) Provide mechanical connection (by others) of truss to bearing plate at joint(s) 5. 8) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) except Ot=lb) 5=156,2=491. 1 9) "NAILED" indicates 3-1 Od (0.1 48"x3") or 2-12d (0.1 48"x3.25") toe-nalls pe, 1- yu-1h lus. 10) In the LOAD CASE(S) section, loads applied to the face of the truss are noted as front'(F) or back (B). LOAD CASE(S) Standard 1) Dead + Roof Live (balanced): Lumber Increase=1.25, Plate lncrease=1.25 Uniform Loads (plf) Vert: 1-3=-70, 4-6=-20 Concentrated Loads (lb) Vert: 9=65(F=32, B=32) 10=51(F=28, B=28) Walter P. Finn PE No'.22839 MiTek USA, Inc. FL Cert 6634 6904 Parke East Blvd. Tampa Fl. 33610 Date: November 12,2018 AWARNING- Verify design parameters and READ NOTES ON THIS AND INCLUDED MffEK REFERANCE PAGEMIP7473re. 1010312015 BEFORE USE. Design valid for use only with MITek0 connectors. This design Is based only upon parameters shown, an8 Is for an Individual building component, not a truss system. Before use, the building designer must verify the applicability of design parometersand �rcperly Incorporate this design into the overall bulldingdesIgn. Bracing indicated Is to prevent buckling of Individual truss web and/or chord members only. Additional temporary and permanent bracing Is always required for stability and to prevent collapse with possible personal Injury and property damabe. For general guidance regarding the M!Tek'. fabrication, storage, delivery, erection and bracing of trusses and truss systems, seeANSVIPII Quallij, Citterla, DSIII-89 and BCSI BuDdIng Component Safety [nfannationavallable from Truss Plate Institute, 218 N. Lee Street Suite 312, Alexandria, VA 22 14.! 6904 Parke East Blvd. Tampa, FL 33610 Job Tru s Truss Type City Ply ACQUAVISTA T15560613 75575 KJC DIAGONAL HIP GIRDER 1 1 Job'Reference (optional) Chambers Truss, Inc., Fad Pierce, FL 2-1-7 5-2-9 3.54 NAILED NAILED 13 8.130 s Mar 11 2018 MiTek Industries, Inc. Mon Nov 12 09:39:27 2018 Page 1 ID:aNkrWfLwRDXTOZhc4Bay—yKyKq-dLtpxKJaryvlq3VO9ovrlZGd5jZ9x—RLIhiwRwyJz7E 7-0-10 9-10-1 NAILED NAILED 3X4 Scale: 1/2"=l' 3x4 14 15 7 6 NAILED 2X3 11 5 3X8 NAILED NAILED 3x4 NAILED 3X10 NAILED NAILED 11 1 V3 -19� 7-0-10 9-10-1 .9.1 1 4-9-2 2-9-7 Plate Offsets (X,Y)-- [2:0-3-8,Edgel, [2:0-0-2,1-6-141, [2:0-0-10,2-4-121 LOADING (psf) SPACING- 2-0-0 CS1. DEFL. in (loc) I/defl Ud PLATES GRIP TCLL 20.0 Plate Grip DOL 1.25 TC 0.40 Vert(LL) 0.10 8 >999 240 MT20 244/190 TCDL 15.0 Lumber DOL 1.25 BC 0.34 Verl(CT) -0.09 8 >999 240 BCLL 0.0 Rep Stress Incr NO WEI 0.18 Horz(CT) 0.02 4 n/a n/a BCDL 10.0 Code FBC2017ITP]2014 Matrix -MS Weight: 47 lb FT = 20% LUMBER - TOP CHORD 2X4 SP M 30 BOT CHORD 2X4 SP M 30 WEBS 2x4 SP No.3 WEDGE Left: 2x8 SP 240OF 2.OE REACTIONS. (lb/size) 4=1 11 /Mechanical, 5=1 9 1 /Mechanical, 2=1 068/0-11-5 Max Harz 2=348(LC 24) Max Uplift 4=-1 27(LC 8), 5=-361 (LC 5), 2=-1 263(LC 8) Max Grav 4=1 11 (LC 1), 5=221 (LC 28), 2=1068(LC 1) FORCES. (lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOPCHORD 2-3=-445/423 BOTCHORD 2-7=-449/287, 6-7=-449/287 WEBS 3-6=-376/589 BRACING - TOP CHORD Structural wood sheathing directly applied or 5-5-11 oc purlins. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. NOTES- I 1) Wind: ASCE 7-10; Vult=170mph (3-second gust) Vasd=132mph; TCDL=4.2psf; BCDL=3.Opsf; h=33ft; B=53ft; L=65ft; eave=7ft; Cat. 11; Exp D; Encl., GCpi=0.18; MWFRS (directional); cantilever left exposed; Lumber DOLL1.60 plate grip DOL=1.60 2) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with anly other live loads. 3) * This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 4) Refer to girder(s) for truss to truss connections. 5) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) except Gt=lb) 4=127,5=36112=1263. 6) "NAILED" indicates 3-1 Od (0.1 48"x3") or 2-12d (0.1 48"x3.25") toe -nails per NOS guidlinels. 7) Hanger(s) or other connection device(s) shall be provided sufficient to support concentraied load(s) 49 lb down and 101 lb up at -2-1-7 on top chord. The design/selection of such connection device(s) is the responsibility of others. 8) In the LOAD CASE(S) section, loads applied to the face of the truss are noted as front (F) or back (B). LOAD CASE(S) Standard 1) Dead + Roof Live (balanced): Lumber Increase=1.25, Plate Increase=1.25 Uniform Loads (plf) Vert: 1-4=-70, 5-8=-20 Concentrated Loads (lb) Vert: 1=-36 7=-51(F=-15, B=-35) 3=-57(F=-13, B=-44) 13=44(F) 14=-276(F=-1381 B=-138) 15=34(F=38, B=-4) Walter P. Finn PE No.22839 MiTek USA, Inc. FL Cert 6634 6904 Parke East Blvd. Tampa FL 33610 Date: November 12,2018 WARNING - Verify design parametersand READ NOTES ON THIS AND INCLUDED MIDEKREFERANCE PAG E M11-7473 rev. 10103)2015 BEFORE USE. Design valid for use only with MITek@ connectors. This design Is based only upon parameters shown, and Is for an Individual building component, not c truss system. Before use, the building designer must verify the applicability of design parameters and i3roperly Incorporate this design Into the overall building design. Bracing Indicated Is to prevent buckling of Individual truss web and/or chord members'only. Additional temporary and permanent bracing MiTek' Is always required for stability and to prevent collapse with possible personal Injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, seeANSLMIJ Quality CrIlluda, D3111-89 and BCSI Bulding Componant 6904 Parke East Blvd. SafolyInformationavallable from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314. Tampa, FL 33610 Job Tru s Truss Type City Ply ACQUAVISTA T15560614 75575 L Roof Special 2 � i Job Reference (optional) Chambers Truss, Inc., Fort Pierce, FL 8.130 s Mar 11 2018 MiTek Industries, Inc. Mon Nov 12 09:39:28 2018 Page 1 ID:aNkrWfLwRDXTOZhc4Bay—yKyKq-5XQB9gKCcG1 cSD4CiWQ4Znpo27uMgNg\�-KRUzMyJz7D -6-0 6-2-8 9-6-0 14-4-0 —11-6.,) 6-2-8 3-3-8 4-10-0 Scale 1:27.6 4x4 4 2X3 5-00 F1_2 13 14 4xl 0 = 53x6 — 12 7 6 3x8 3x4 11 3x5 9-6-0 14-4-0 9-6-0 4-10-0 Plate Offsets (X,Y)-- [2:0-0-2,Edgel, [5:Edge,0-0-81 LOADING (psf) SPACING- 2-0-0 CS1. DEFL. in (loc) I/defl Ud PLATES GRIP TCLL 20.0 Plate Grip DOL 1.25 TC 0.39 Vert(LL) -0.13 7-11 >999 360 MT20 244/190 TCDL 15.0 Lumber DOL 1.25 BC 0.41 Vert(CT) -0.30 7-11 >560 240 BCLL 0.0 Rep Stress Incr YES WB 0.43 Horz(CT) -0.02 12 n/a n/a BCDL 10.0 Code FBC2017[TP12014 Matdx-MS Wind(U-) 0.11 7-11 >999 240 Weight: 70 lb FT 20% LIUMBER- TOP CHORD 2X4 SP M 30 BOT CHORD 2X4 SP M 30 WEBS 2x4 SP No.3 OTHERS 2x4 SP No.3 REACTIONS. (lb/size) 2=749/0-8-0,12=607/0-3-8 Max Harz 2=280(LC 12) Max Uplift 2=-735(LC 12),12=-528(LC 12) FORCES. (lb) -Max. Comp./Max. Ten. -All forces 250 (lb) or less except when shown. TOPCHORD 2-3=-1048/1107, 3-4=-723/746, 4-5=-698f,715 BOTCHORD 2-7=-1188/1000 WEBS 3-7=-527[770,+7=-224/304, 5-7=-488/505, 5-12=-673/698 BRACING- TOPCHORD Structural wood sheathing directly applied or 6-0-0 oc purlins, except end verticals. BOTCHORD Rigid ceiling directly applied or 6-6-5 oc bracing. NOTES- 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-10; Vult=170mph (3-second gust) Vasd=132mph; TC DL=4.2psf; BCDLj3.Opsf; h=33ft; B=53ft; L=65ft; eave=7ft; Cat. 11; Exp D; Encl., GCpi=0.18; MWFRS (directional) and C-C Exterior(2) -1-6-0 to 4-11-13� Interion(l) 4-11-13 to 9-6-0, Exterior(2) 9-6-0 to 13-10-12 zone;C-C for members and forces & MWIFFIS for reactions shown; Lumber DOL=11.60 plate grip DOL=1.60 3) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with a�y other live loads. 4) *.This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 5) Bearing at joint(s) 12 considers parallel to grain value using ANSVTPl 1 angle to grain formula. Building designer should verify capacity of bearing surface. 1 6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) except at=lb) 2=735,12=528. Walter P. Finn, PE No.22839 MiTek USA, ]he. FL Carl 6634 6904 Parke East Blvd. Tampa Fl. 33610 Date: November 12,2018 WARNING - Verify design parameters and READ NOTES ON THIS A ND INCLUDED MITEK REFERANCE PAGE MII-7473 rev. 10103120 IS BEFORE USE. Design valid for use only with MITek9 connectors. This design Is based only upon parameters shown, and Is for an Individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly Incorporate this design Into the overall building design. Bracing Indicated Is to prevent buckling of Individual truss web and/or chord member§ only. Additional temporary and permanent bracing MiTbak' Is always required for stability and to prevent collapse with possible personal Injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems. seeANStMI1 Qual" CrIleft, DSB-89 and BCSI Building Component 6904 Parke East Blvd. Safety Informationovallable from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22114.1 Tampa, FL 33610 Job Truss Truss Type Qty Ply ACQUAVISTA T15560615 75575 Hip I Job Reference (optional) Chambers Truss, Inc., Fort Pierce, FL 8.130 s Mar 11 2018 MiTek Industries, Inc. Mon Nov 12 09:39:29 2018 Page 1 ID:aNkrWfLwRD)CrOZhc4Bay—yKyKq-Zi—ZMOLqNa9T4NfOGDxK6_M7JWEvPrseD—B1 WpyJz7C -'1-6*0 5-8-12 9-0-0 000 1 14-4-0 .B.0 5-6-12 ! 3-3-4 4-4-0 44. = 45 = 0 L 5-oo 5-2 2x3 WO 3 6 3x6 15 x1' >6 3, E40 2 it C>< I U5:�� 9 B3x4 7 3x4 3x4 11 3x5 Plate LOADING (pst) SIP ACING- 2-0-0 CSI. DEFL. 1 in (loc) I/d6f] Ud TCLL 20.0 Plate Grip DOL 1.25 TC 0.39 Verl(LL) -0,13 9-13 >999 360 TCDL 1 5.0 Lumber DOL 1 1 25 BC 0.39 Vert(CT) -0.29 9-13 >592 240 BCLL 0. Rep Stress Incr YES WB 0.37 Horz(CT) -0.62 14 n/a n/a BCDL 10. Code FBC2017/TPI2014 Matdx-MS Wind(LL) 0.14 9-13 >999 240 LIUMEIER- TOPCHORD 2X4 SP M 30 BOTCHORD 2x4 SP M 30 WEBS 2x4 SP No.3 OTHERS 2x4 SP No.3 REACTIONS. (lb/size) 2=749/0-8-0,14=607/0-3-8 Max Horz 2=280(LC 12) Max Uplift 2=-735(LC 12),14=-528(LC 12) Max Grav 2=751 (LC 17), 14=607(LC 1) FORCES. (lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when TOPCHORD 2-3=-1 084/1232, 3-4---71 W774, 4-5=-6591777, 5-6=-l695f767 BOTCHORD 2-9=-1 323/1043, 8-9=-632/585 WEBS 3-9=-565/841, 4-9=-284/343, &B=-590/546, 6-14=-665/708 Scale = 1:27.5 14 PLATES GRIP MT20 244/190 Weight: 74 lb FT = 20% IBRACING- TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins, except end verticals. BOT CHORD Rigid ceiling directly applied or 6-2-2 oc bracing. NOTES - I ) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-10; Vult=170mph (3-second gust) Vasd=132mph; TCIDL=4.2psf; BCDLL3.0psf; h=33ft; B=53ft; L=65ft; eave=7ff, Cat. 11; Exp D; Encl., GCpi=0.18; MWIFFIS (directional) and C-C Exterior(2) -1-6-0 to 4-11-10, Interior(l) 4-11-13 to 9-0-0, Exterior(2) 9-0-0 to 10-0-0 zone;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) Provide adequate drainage to prevent water ponding. 4) This truss has been clesigne I d for a 10.0 psf bottom chord live load nonconcurrent with� any other live loads. 5) * This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 1 6) Bearing at joint(s) 14 considers parallel to grain value using ANSIITIPI 1 angle to grain formula. Building designer should verify. capacity of bearing surface. 7) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) except at=lb) 2=735,14--528. Walter P. Finn PE No.22839 MiTek USA, Inc. FL Cort 6634 6904 Parke East Blvd. Tampa FL 33610 Data: 14 November 12,2018 ,& WARNING- Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEKREFERANCE PAGE M11-7473 rev. IW03)2015 BEFORE USE. . Design valid for use only.with MITek@ connectors. This design Is based only upon parameters shown, pnd Is for an Individual building component, not a truss system. Before use, the building designer must verity the applicability of design parameters and properly incorporate this design Into the overall building design. Bracing Indicated Is to prevent buckling of Individual truss web and/or chord members only. Additional temporary and permanent bracing MiTek' Is always required for stability and to prevent collapse with possible personal Injury and property domage, For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, seeANSVFPII Quall CrIllada. DSB-89 and SCSI Bulding Component HY1 6904 Parke East Blvd. Scifetylnfaffnationavailable from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22 4. Tampa, FIL 33610 Job Tru s Truss Type Qty Ply AC QUAVISTA T15560616 75575 L2 Hip Job Reference (optional) L,namoers i russ, inc., rorl rierce, M 2 3x4 = 5. 0 0 F1 _2 7-0-0 14 0. 1 JU S Mar I I 4U 10 Ml I UKH 1UU5LF1U5, H W. IVIU11 INUV 14 WV;0!2;0U 4U 10 r dye I ID:aNkrWfLwRD)CrOZhc4Bay—yKyKq-lwYxaMMS8tHKhXEaqxTZfCu5RwaW8JxoRewa2FyJz7B 12-0-0 4�1-1 5-0-0 L2 .0 4x10 = 8 2X3 4x5 4 7 3XB 4xB 5 3x6 6 3X4 11 Scale = 1:27.2 I? c? CU 13 0 7-0-0 5-0-0 Plate Offsets (X,Y)-- [2:0-1-10,Edqel,[3:0-6-8,0-2-01,[5:0-1-8,0-0-121 LOADING (ps� SPACING- 2-0-0 CS1 DEFL. in (loc) I/defl Ud PLATES GRIP TCLL 20.0 Plate Grip DOL 1.25 TC 0.59 Vert(LLY -0.06 B-12 >999 360, MT20 244/190 TCDL 15.0 Lumber DOL 1.25 BC 0.43 Vert(CT) -0.15 8-12 >999 240 BCLL 0.0 Rep Stress Incr YES WB 0.32 Horz(CT) -0.01 13 n/a n/a BCDL 10.0 Code FBC2017rrPI2014 Matdx-MS Wind(LL) 0.16 8-12 >999 240 Weight: 71 lb FT = 20% LUMBER - TOP CHORD 2X4 SP M 30 BOT CHORD 2X4 SP M 30 WEBS 2x4 SP No.3 OTHERS 2x4 SP No.3 REACTIONS. (lb/size) 2=749/0-8-0,13=607/0-3-8 Max Horz 2=280(LC 12) Max Uplift 2=-735(LC 12),13=-528(LC 12) Max Grav 2=756(LC 17),13=607(LC 1) FORCES. (lb) -Max. Comp./Max, Ten. -All forces 250 (lb) or less except when shown. TOPCHORD 2-3=-991/1093, 3-4=-4621594, 4-5=-483/581 BOTCHORD 2-8=-1 100/892, 7-8=-1 104/902 WEBS 3-8=-73/289, 3-7=-559002, 5-7=-587/492, 5-13=-6341743 BRACING - TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc pudins, except end verticals. BOTCHORD Rigid ceiling directly applied or 6-1 -0 oc bracing. NOTES- 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-10; Vult=1 70mph (3-second gust) Vasd=1 32mph; TC DL=4.2psf; BCDLi3.Opsf; h=33ft; B=53ft; L=65ft; eave=7ft; Cat. 11; Exp D; Encl., GCpi=0.18; MWFRS (directional) and C-C Exterior(2) -1-6-0 to 4-11-13, Interior(l) 4-11-13 to 7-0-0, Exterlor(2) 74-0 to 12-0-0 zone;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) Provide adequate drainage to prevent water ponding. 1 4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 5) * This truss has been designed for a live load of 20.Opsf on the bottom chord in all area� where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 6) Bearing at joint(s) 13 considers parallel to grain value using ANSI/TPI 1 angle to grain formula. Building designer should verify capacity of bearing surface. 7) Provide mechanical connection (by others) of truss to bearing plate Capable of withstanLg 100 lb uplift at joint(s) except Ot=lb) 2=735,13=528. Walter P. Finn PE No.22839 MiTelk USA, Inc. FL Carl 68NI 6904 Parke East Blvd. Tampa FL 33610 Date: November 12,2018 ,& WARNING- Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERANCEPAGIE M11-7473 re. 10/0=015 BEFORE USE. I Design valid for use only with MITek@ connectors. This design is based only upon parameters shown, ari d Is for an Individual building component not a truss system. Before use, the building designer must verify the applicability of design parameters andiproperly Incorporate this design Into the ove".1i building design. Bracing Indicated Is to prevent buckling of Individual truss web and/or chord members only. AddIllonal temporary and permanent bracing M!Tek' Is always required for stability and to prevent collapse with possible personal Injury and property damd ge. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, seeANSVTPIJ QualftV Crfforla, DSB-89 and BCSI Building Component 6904 Parke East Blvd. SafatV Informationovallable from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 223111. Tampa, FL 33610 Job Truss Truss Type Cty Ply AC QUAVISTA . T15560617 � 75575 L3 Hip 1 1 Job Reference (optional) unamners I russ, Inc., i--ort merce, I- -I_ tm ju s mar I I ZU1 t3 mi I eK Inausines, Inc. Mon NOV I Z IJIJ:UV:�JU ZU1 It$ t-age i ID:aNkrWfLwRDXTOZhc4Bay—yKyKq-1 wYxaMMSBtHKhXEaqxTZfCu5W.wa78HKoRewa2FyJz7B '5-0-0 9.6.0 14-0-0 16-4-P T-,. 0 .6—') 1 5-0-0 4-6-0 4-6-0 5.00 r1­2 2 3x4 5-0-0 5-0-0 6xB = 73x4 = 3X4 4 LOADING (psf) SPACING- 2-0 CSI DEFL. in (loc) I/def] Ud TCLL 20.0 Plate Grip DOL .�O 1 5 TC 0.58 Veri(LL) -0.13 6-7 >999 360 TCDL 15 -0 Lumber DOL 1.25 BC 0.39 Verl(CT) -0.26 6-7 >646 240 BCLL 0.0 Rep Stress Incr YES WB 0.42 Horz(CT) -0.02 12 n1a n/a BCDL 10.0 Code FBC2017[rPI2014 Matrix -MS Wind(LL) 0.06 7-11 >999 240 LIUMEIER- TOP CHORD 2X4 SP M 30 *Except* 3-5: 2x6 SP No.2 BOT CHORD 2x4 SP M 30 WEBS 2x4 SP No.3 OTHERS 2x4 SP No.3 REACTION& (lb/size) 2=750/0-8-0,12=606/0-3-0 Max Harz 2=269(LC 12) Max Uplift 2=-737(LC 12),12=-525(LC 12) FORCES. (lb) -Max. Comp./Max. Ten. -All forces 250 (lb) or less except when shown. TOP CHORD 2-3=-1 181/1270, 3-4=-1 108/1277, 6-8=-520/459, 5-8=-520/459 BOT CHORD 2-7=-1 273/1097, 6-7=-1 310/965 WEBS 4-6=-895/1288, 5-12=-6211774 NOTES- 1) U , nbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-10; Vult=170mph (3-second gust) Vasd=132mph; TCDL=4.2psf; BCDL 11; Exp D; Encl., GCpi�0.118; MWFFIS (directional) and C-C Exterior(2) zone;C-C for ml shown; Lumber DOL=1.60 plate grip DOL=1.60 3) Provide adequate drainage to prevent water ponding. 4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with 5) * This truss has been designed for a live load of 20.Opsf on the bottom chord in all arel will fit between the bottom chord and any other members. 6) Bearing at joint(s) 12 considers parallel to grain value using ANSI/TPI 1 angle to grain capacity of bearing surface. 7) Provide mechanical connection (by others) of truss to bearing plate capable of withstal 2=737,12=525. Scale = 1:27.2 3x6 5 6xB co 7 ch 19 12 6 3x8 PLATES GRIP MT20 244/190 Weight: 74 lb FT = 20% BRACING - TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins, except end verticals. BOTCHORD Rigid ceiling directly applied or 6-4-9 oc bracing. ; h=33ft; B=53ft; L=65ft; eave=7ft; Cat. and forces & MWFRS for reactions iy other live loads. where a rectangle 3-6-0 tall by 2-0-0 wide Building designer should verify 100 lb uplift at joint(s) except at=lb) Walter P. Finn PE No'.22839 MlTek USA, Inc. FL Cart 6634, 6904 Parke East Blvd. Tampa FL 3 3610 Date: November 12,2018 ,& WARNING- Vertry desIgn parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERANCE PAGE Ml,,7473 rev. 1010312015 BEFORE USE. Design valid for use only with MIT91<0 connectors. This design Is based only upon parameters shown, and Is for an Individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly Incorporate this design Into the overall buildingdosign. Bracing indicated Is to prevent buckling of Individual truss web and/or chord members only. Additional temporary and permonentbrocing M!Tek* Is always required for stability and to prevent collapse with possible personal Injury and property do�'cge For general guidance regarding the fabrication, storage, delivery. erection and bracing of trusses and truss systems, seeANSVIPIJ Qual 2 1. DSB-69 and BCS1 Building Component I Cgd. Safety Informatlanarvalloble from Truss Plate Institute, 218 N. Lee Street, Suite 312, Adexandria, VA22 4. 6904 Parke East Blvd. Tampa, I'L 33610 Job Truss Truss Type I Qty Ply ACQUAVISTA i T1 5560618 75575 M Monopitch 12 1 . Job Reference (optional) unamoers i russ, inc., r-on merce, r-L. 1-6-0 3 2 3x4 = 7-8-6 13 0" "" 5 "lut 1 1 " 1 o Ivil I er' 11 luutill lt!h, 111. 1viul 1 11uv 1 4 uu;Z0 1 4v 1 0 rdyu I ID:aNkrWfLWRDXTOZhc4Bay—yKyKq-V66JniM4vBPBJhon0e-oBPRHAKxutb5kglgBahyJz7A 14-4-0 4x6 5 5.005-2 3x4 55� 4 - M = x6 12 2S 7 6 2X3 11 3X4 Scale = 1:36.4 Plate Offsets (X,Y)-- [2:0-2-0,Edgel, [3:0-3-0,Edgel I LOADING (psf) SPACING- 2-0-0 CSI. DEFL. in (loc) I/defl Ud PLATES GRIP TCLL 20.0 Plate Grip DOL 1.25 TC 0.53 Vert(LL) -0.07 7-11 >999 360 MT20 244/190 TCDL 15.0 Lumber DOL 1.25 BC 0.35 Vert(CT) -0.18 7-11 >950 240 BCLL 0.0 Rep Stress Incr YES W13 0.97 Horz(CT) -0.02 12 n/a n/a BCDL 10.0 Code FBC2017rrP]2014 Matrix -MS Wind(LL) 0.16 7711 >999 240 Weight: 77 lb FT = 20% LIUMEIER- BRACING- TOPCHORD 2x4 SP M 30 TOPCHORD Structural wood sheathing directly applied or 6-0-0 oc purlins, BOTCHORD 2x4 SP M 30 except end verticals. WEBS 2x4 SP No.3 BOTCHORD Rigid ceiling directly applied or 6-10-0 oc bracing. OTHERS 2x4 SP No.3 REACTIONS. (lb/size) 2=749/0-8-0,12=607/0-3-8 Max Harz 2=615(LC 12) Max Uplift 2=-640(LC 12),12=-622(LC 12) Max Grav 2=776(LC 17), 12=681 (LC 17) FORCES. (lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOPCHORD 2-4=-1001/587, 6-8=-434/527, 5-8=-434/527 BOTCHORD 2.-7=-926/984, 6-7=-926/984 - WEBS 4-7=-21/328, 4-6=-1 052/996, 5-12=-708/640 NOTES- 1) Wind: ASCE 7-10; Vult=170mph (3-second gust) Vasd=132mph; TCDL=4.2psf; BCD1. 11; Exp D; Encl., GCpi=O. 18; MWFRS (directional) and C-C Extedor(2) -1-6-0 to 4-11 -1 members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DC 2) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with 3) * This truss has been designed for a live load of 20.Opsf on the bottom chord in all are will fit between the bottom chord and any other members. 4) Bearing at joint(s) 12 considers parallel to grain value using ANSVTP1 1 angle to grain capacity of bearing surface. 5) Provide mechanical connection (by others) of truss to bearing plate capable of withsta 2=640,12=622. I.Opsf; h=33ft; B=53ft; L=65ft; eave=7ft; Cat. Interior(l) 4-11-13 to 13-10-12 zone;C-C for :1.60 y other live loads. where a rectangle 3-6-0 tall by 2-0-0 wide Tnula. Building designer should verify ng 100 lb uplift at joint(s) except at=lb) Walter P. Finn PE No.22839 MiTek USA, Inc. Fl. Cori 6634 6904 Parke East Blvd. Tampa FL 33610 Date: November 12,2018 WARNING - Verify design parameters and RE41? NOTES ON THIS AND INCLUDED MITEK REFERANCE P I AGE MIP7473 rev. la/=015 BEFORE USE. Design valid for use only with IVITek@ connectors. This design Is based only upon parameters shown, and Is for an Individual building component, not a truss system. Before use, the building designer must verity the applicability of design parameters arid properly Incorporate this design Into the overall building design. Bracing Indicated Is to prevent buckling of Individual truss web and/or chord members only. Additional temporary and permanent bracing MiTek' Is always required for stability and to prevent collapse with possible personal Injury and property dar�, age. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, seeANSVMII Quail 2T, Citteria, DSB-89 and BCSI Bullding Component Safety triformationovailable from Truss Plate Institute, 218 N. Lee Street, Suite 312, AJexandria, VA 22 14. 6904 Parke East Blvd. Tampa, FL 33610 Job Truss Truss Type Qty Ply AC QUAVISTA T15560619 � 75575 M11 Half Hip 1 1 Job Reference (optional) uriamners I russ, Inc., �-ort merce, FIL d.13u s mar i i xuit3 mt I eK inausines, Inc. man r4ov iz uv:dd:;jz Zulu rage i ID:aNkrWfLwRDXTOZhc4Bay—yKy�q-zlgi?2NigVX2xqNzxMVlkd—RBkFec9T5vyPh78yJz79 7-8-4 12-4-0 1 1, - —1-01 4_4-00 7-8-4 4-7-12 Scale = 1:36.7 2 3X4 = 5-oo 5_2 6x8 3 15 14 2X3 11 3x6 4X4 5x8 4 5 7 6 3x8 3X4 11 LOADING (pso SPACING- 2-0-0 CSI. DEFL. in (loc) I/defl Lid TCLL 20.0 Plate Grip DOL 1.25 TC 0.57 Vert(LL) -0.07 B-12 >999 360 TCDL 15.0 Lumber DOL 1.25 BC 0.38 Vert(CT) -0.18 8-12 >922 240 BCLL 0.0 Rep Stress Incr YES WEI 0.57 Horz(CT) -0.01 13 n/a n1a BCDL 10.0 Code FBC2017fTP12014 Matrix -MS Wind(LL) 0.17 B-12 >999 240 LIUMBER- TOP CHORD 2X4 SP M 30 BOT CHORD 2X4 SP M 30 WEBS 2x4 SP No.3 OTHERS 2x4 SP No.3 REACTIONS. (lb/size) 2=749/0-8-0,13=607/0-3-8 Max Harz 2=556(LC 12) - Max Uplift 2=-663(LC 12),13=-599(LC 12) Max Gram 2=779(LC 17),13=654(LC 17) FORCES. (lb) -Max. Comp./Max. Ten. -All forces 250 (lb) or less except when shown. TOP CHORD 2-3=-998/831, 3-4=-286/199, 4-5=-204/257 BOTCHORD 2-8=-1210/967, 7-8=-1210/967 WEBS 3-8=-531307, 3-7=-919/1144, 5-7=-765/602, 5-13---682/844 NOTES- 1) Wind: ASCE 7-10; Vult=170Mph (3-second gust) Vasd=132mph; TCDL=4.2psf; BCDL 11; Exp D; Encl., GCpi=O.l 8; MWFRS (directional) and C-C Exterior(2) -1-6-0 to 4-11 -1 12-4-0 to 13-10-12 zone;C-C for members and forces & MWFRS for reactions shown; 2) Provide adequate drainage to prevent water ponding. 3) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with 4) * This truss has been designed for a live load of 20.Opsf on the bottom chord in all are; will fit between the bottom chord and any other members. 5) Bearing at joint(s) 13 considers parallel to grain value using ANSIITPI 1 angle to grain capacity of bearing surface. 6) Provide mechanical connection (by others) of truss to bearing plate capable of withstal 2=663,13=599. 13 PLATES GRIP MT20 244/190 Weight: 88 lb FT = 20% BRACING- TOPCHORD Structural wood sheathing directly applied or 6-0-0 oc purlins, except end verticals. BOTCHORD Rigid ceiling directly applied or 5-10-15 oc bracing- I.Opsf; h=33ft; B=53ft; L--�65ft; eave=7ft; Cat. Interior(l) 4-11-13 to 12-4-0, Exterior(2) imber DOL=1.60 plate grip DOL=11.60 iy other live loads. I where a rectangle 3-6-0 tall by 2-0-0 wide Building designer should verify 100 lb uplift at joint(s) except Ot=lb) Walter P. Finn PE No.22839 MiTek USA, Inc. FL Cart 6634. 6904 Pirko East Blvd. Tampa FL 33610 Date: November 12,2018 ,& WARNING - Verify design parametesandREAD NOTES ON THISAND INCLUDED MITEKREFERANCEPA I GE 11111-7473 rev. 10/03)20 15 BEFORE USE. Design valid for use only with M[Tek@ connectors. This design Is based only upon parameters shown, an!, d Ii for an Individual building component not a truss system. Before use, the building designer must verify the applicability of design parameters and properly Incorporate this design Into the overall building design, Bracing Indicated Is to prevent buckling of Individual truss web and/or chord memb6rs only. Additional temporary and permanent bracing MiTak' is always required for stability and to prevent collapse with possible personal Injury and property dam6ge. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, seeANSVFP17 Quality Crillaft, DSB49 and BCSI Building Component 6904 Parke East Blvd. Safety [nformoffonovallable from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314. 1 Tampa, FL 33610 . . Job Tru s Truss Type Qty Ply ACQUAVISTA T15560620 75575 M2 Half Hip 1 Job Reference (optional) Gharribers I russ, Inc., i-ort Pierce, i-L tm;ju a mar I I ZU16 rill I eK inausines, Inc. man NOV 1Z UU:JU:JZ ZVItJ Page i ID:aNkrWfLwRDXTOZhc4Bay—yKyKq-z!gi?2NigVX2xqNzxMVI kd—QVkEJcBt5vyPh78yJz79 -1-6-0 7-8-5 1 0'dL 14-4-0 1.6_0 1 1 �;O 7-8-5 2-7 1 4-0-0 14 1 '::�4 3X5 = 5. 0 0 F1 2- 7-8-5 15 3x6 Scale = 1:31.1 4x4 5x8 4 5 6x8 3 8 7 6 2X3 3xB 3x4 LOADING (pso SPACING- 2-0-0 CS1. DEFL. in (loc) I/defi Ud TCLL 20.0 Plate Grip DOL 1.25 TC 0.62 Vert(LL) -0.07 B-12 >999 360 TCDL 15.0 Lumber DOL 1.25 BC 0.47 Vert(CT) -0.18 B-12 >930 240 BC Rep Stress Incr YES WB 0.42 Horz(CT) -0.01 13 n/a n/a BC Code FBC2017fTP12014 Malrix-MS Wind(LL) 0.18 B-12 >938 240 LIUMBER- TOP CHORD 2X4 SP M 30 BOT CHORD 2X4 SP M 30 WEBS 2x4 SP No.3 OTHERS 2x4 SP No.3 REACTIONS. (lb/size) 2=749/0-8-0,13=607/0-3-8 Max Horz 2=480(LC 12) Max Uplift 2=-689(LC 12),13=-574(LC 12) Max G rav 2=777(LC 17), 13=623(LC 17) FORCES. (lb) -Max. Comp./Max. Ten. -All forces 250 (lb) or less except when shown. TOPCHORD 2-3=-996/939, 3-4=-516/579, 4-5=-430/527 BOTCHORD 2-8=-1 207/951, 7-8=-1 207/951 WEBS 3-8=-1 121299, 3-7=-804/1048, 5-7=-742/601, 5-13=-653/771 NOTES- 1) Wind: ASCE 7-10; Vult=170mph (37second gust) Vasd=132mph; TCDL=4.2psf; BCDL 11; Exp, D; Encl., GCpi=0.18; MWFRS (directional) and C-C Exterion(2) -1-6-0 to 4-11-1 10-4-0 to 13-10-12 zone;C-C for members and forces & MWFRS for reactions shown; 2) Provide adequate drainage to prevent water ponding. 3) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with 4) * This truss has been designed for a live load of 20.Opsf on the bottom chord in all arei will fit between the bottom chord and any other members. 5) Bearing at joint(s) 13 considers parallel to grain value using ANSIITPI I angle to grain capacity of bearing surface. 6) Provide mechanical connection (by others) of truss. to bearing plate capable of withstal 2=689,13=574. 13 PLATES GRIP MT20 244/190 Weight: 82 lb FT = 20% BRACING- TOPCHORD Structural wood sheathing directly applied or 6-070 oc purlins, except end verticals. BOTCHORD Rigid ceiling directly applied or 5-8-2 oc bracing. I.Opsf; h=33ft; B=53ft; L=65ft; eave=7ft; Cat. Interion(l) 4-11-13 to 10-4-0, Exterior(2) imber DOL=1.60 plate grip DOL=1.60 iy other live loads. where a rectangle 3-6-0 tall by 2-0-0 wide Building designer should verify 100 lb uplift at joint(s) except Ot=lb) Walter P. Finn PE No.22839 MiTek USA, Inc. FL Carl 6634 6904 Parke East Blvd. Tampa FL 33610 Data: November 12,2018 'A WARNING- Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERANCE PAGE 11,111-7473 rev. 10/=015 BEFORE USE. Design valld for use only with MITek8 connectors. This design Is based only upon parameters shown, and Is for an Individual building component, not MF a truss system. Before use, the building designer must verity the applicability of design parameters and properly incorporate this design Into the overall building design. Bracing Indicated Is to prevent buckling of Individual truss web and/or chord members only. Additional temporary and permanent bracing MiTek* Is always required for stability and to prevent collapse with possible personal Injury and property dambge. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, seeANSVTPII Quallty6tterla. DSB-89 and BCSI Building Component 6904 Parke East Blvd. Safety Informationavailable from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 2231�1. : . : I Tampa, FL 33610 job Tru s Truss Type Oily Ply ACQUAVISTA T15560621 75575 MV2 Valley 2 Job Reference (optional) L;r1ambers truss, Inc., l--ort Vierce, l­-L 1 3x4 �� 0. IOU 5 Mar I I eU 10 IVII I eK 111LIUSETIL5, H ILL IVIUI I IMUV 14 UUmOV.00 4U I a rdYu I ID:aNkrWfLwRDXTOZhc4Bay—yKyKq-F�VE4COOLRogvl�-y9V30GGqWjN8hSLkgEBc9EfayJz78 2-0-0 1 2-0-0 5.00 F1_2 2 3 Scale = 1:6.9 LOADING (psf) SPACING- 2-0-0 CS1. DEFL. in (loc) I/defl Ud PLATES GRIP TCLL 20.0 Plate Grip DOL 1.25 TC 0.10 Vert(LL) n1a n/a 999 MT20 244/190 TCDL 15.0 Lumber DOL 1.25 BC - 0.03 Vert(CT) n/a n/a 999 BCLL 0.0 Rep Stress Incir YES WB 0.00 Horz(CT) -0.00 2 n/a n/a BCDL 10.0 Code FBC2017fTP12014 Matrix-P Weight: 5 lb FT = 20% LIUMBER- TOPCHORD 2x4 SP No.3 BOTCHORD 2x4 SP No.3 REACTIONS. (lb/size) 1=57/2-0-0, �=44/2-0-0, 3=13/2-0-0 Max Harz 1=48(LC 12) _ Max Uplift 1=-39(LC 12), 2=-63(LC 12) Max G rev I =60(LC 17), 2=51 (LC 17), 3=25(LC 3) FORCES. (lb) -Max. Comp./Max. Ten. -All forces 250 (lb) or less except when shown. NOTES- 1) Wind: ASCE 7-10; Vult=170mph (3-second gust) Vasd=132mph; TCDL=4.2psf; BCDL 11; Exp D; Encl., GCpi=0.18; MWFRS (directional) and C-C Exterior(2) zone;C-C form, shown; Lumber DOL=1.60 plate grip DOL=1.60 2) Gable requires continuous bottom chord bearing. 3) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with 4) * This truss has been designed for a live load of 20.Opsf on the bottom chord in all are will fit between the bottom chord and any other members. 5) Bearing at joint(s) 2 considers parallel to grain value using ANSVTPI 1 angle to grain f, capacity of bearing surface. 6) Provide mechanical connection (by others) of truss to bearing plate capable of withsta BRACING - TOP CHORD Structural wood sheathing directly applied or 2-0-0 oc puffins. BOTCHORD Rigid ceiling directly applied or 10-0-0 oc bracing. :; h=33ft; B=53ft; L=65ft; eave=7ft; Cat. and forces & MWFRS for reactions' iy other live loads. where a rectangle 3-6-0 tall by 2-0-0 wide nula. Building designer should verify ng 100 lb uplift at joint(s) 1, 2. Walter P. Finn PE No.22839 MiTek USA, litc. FL Cart 6634 6904 Parke East Blvd. Tampa FL 33610' Data: November 12,2018 WARNING - Verify design parameters andREAD NOTES ON THIS AND INCLUDED MITEKREFERANCE PAGE MIP7473 rev. 10103V2015 BEFORE USE. Design valid for use only with MITek@ connectors. This design Is based only upon parameters shown akd Is for an Individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters �na properly Incorporate this design Into the overall building design. Bracing Indicated Is to prevent buckling of Individual truss web and/or chord members only. Additional temporary and permanent bracing MiTek' Is always required for stability and to prevent collapse with possible personal Injury and property dambge. For general guidance regarding the . fabrication, storage, delivery, erection and bracing of trusses and truss systems, seeANSLITPII Qual Criteria, DSB-89 and BCSI Building Component 6904 Parke East Blvd. Safety Infounationovc1lable from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 2 2110. Tampa, FL 33610 Job Tru s Truss Type Qty Ply ACQUAVIII TA T15560622 MV4 Valley 1 1 Job Reference (optional) Chambers Truss, Inc., Fort Pierce, FIL 8.130 si Mar 11 2018 MiTek Industries, Inc. Mon Nov 12 09:39:34 2018 Page 1 ID:aNkrWfLwRDXTOZhc4Bay—yKyKq-vhoSQkPzC6omABXM3mXvp231?X?84BvNMGuoBOyJz77 4-0-0 4-o-o scale = 1:11.1 3x4 11 5.00 FIT "_!� 3x4 �� 3X4 11 LOADING (psf) SPACING- 2-0-0 CS1. DEFL. in (loc) I/defl Ud PLATES GRIP TCLL 20.0 Plate Grip DOL 1.25 TC 0.68 Vert(LL) n/a n/a 999 MT20 244/190 TCDL 15.0 Lumber DOL 1.25 BC 0.19 Vert(CT) n/a n/a 999 BCLL 0.0 Rep Stress Incr YES WB 0.00 Horz(CT) 0.00 n/a n/a BCDL 10.0 Code FBC2017/TP12014 Matdx-P Weight: 13 lb FT = 20% LUIMIBER- TOP CHORD 2x4 SP No.3 BOTCHORD 2x4 SP No.3 WEBS 2x4 SP No.3 REACTIONS. (lb/size) 1=141/4-0-0,3=141/4-0-0 Max Horz 1 =1 19(LC 12) Max Uplift 1=-96(LC 12), 3=-145(LC 12) Max Grav 1 =1 48(LC 17), 3=1 58(LC 17) FORCES. (lb) -Max. Comp./Max. Ten. -All forces 250 (lb) or less except when shown. TOP CHORD 2-3=-158/294 NOTES- 1) Wind: ASCE 7-10; Vult=170mph (3-second gust) Vasd=132mph; TCDL=4.2psf; BCDL=' 11; Exp D; Encl., GCpi=0.18; MWFRS (directional) and C-C Exterior(2) zone;C-C for merr shown; Lumber DOL=11.60 plate grip DOL=1.60 2) Gable requires continuous bottom chord bearring. 3) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with a[ 4) * This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas will fit between the bottom chord and any other members. 5) Provide mechanical connection (by others) of truss to bearing plate capable of withstand 3=1 45. BRACING - TOP CHORD Structural wood sheathing directly applied or 4-0-0 oc purlins, except end verticals. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. .Opsf; h=33ft; B=53ft; L=65ft; eave=7ft; Cat. bers and forces & MWFRS for reactions other live loads. iere a rectangle 3-6-0 tall by 2-0-0 wide 100 lb uplift at joint(s) 1 except at=lb) Walter P. Finn PE No.22839 MiTek USA, Inc. Fl. Cert GGX 6904 Parke East Blvd. Tampa FL 33810 Data: November 12,2018 ,& I&AnNtfir - Verify design parameters and READ NOTES ON THIS AND INCLUDED miTEK REFERANCE PAGE 1 11,111-7473 rev.'1010312015 BEFORE USE. Design valid for use only with MITek@ connectors. This design Is based only upon parameters shown, and is for an Individual building component no a truss system. Before use, the building designer must verity the applicability of design parameters and properly Incorporate this design Into the ovei!ail building design, Bracing Indicated is to prevent buckling of Individual truss web and/or chord members drily. Additional temporary and permanent bracing MiTek' Is always required for stability and to prevent collapse with possible personal Injury and property domagel For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, seeANSVFPII Quality Crffoda, DSB-89 and BCSI Building Component 6904 Parke East Blvd. Safety Informationavollable from Truss Plate Institute, 218 N. Lee Street Suite 312, Alexandria, VA 22314. J Tampa, FL 33610 Job Truss Truss Type I Qty Ply -1 ACQUAVISTA i T15560623 75575 MV6 Valley 1 � . I Job Reference (optional) L;namDers I russ, Inc., t-ort t-ierce, I-L mtou5 rviar i i euic rvuiuK inuutariub, mu. iviuji imuv ie uv;aw;0% 4uio rayu I I ID:aNkrWfLwRDXTOZhc4Bay—yKyKq-vhoSQkPzC6omABXM3mxvp23pUXOJ498NMGuoBOyJz77 6-0-0 1 6-0-0 2 10 5.00 F1 _2 3X4 11 3 4 3X4 -5- 2X3 11 3x4 11 Scale = 1: 15.7 LOADING (pst) SPACING- 2-0-0 CSI. DEFL. in (loc) I/def] Ud PLATES GRIP TCLL 20.0 Plate Grip DOL 1.25 TC 0.39 Veri n/a n/a 999 MT20 244/190 TCDL 15.0 Lumber DOL 1.25 BC 0.12 Vert(CT) n/a n/a 999 BCLL 0.0 Rep Stress Incr YES W13 0.18 Horz(CT) 0.00 n/a n/a BCDL 10.0 Code FBC2017fTP12014 Matrix-P Weight: 21 lb FT = 20% LIUMBER- TOP CHORD 2x4 SP No.3 BOT CHORD 2x4 SP No.3 WEBS 2x4 SP No.3 OTHERS 2x4 SP No.3 REACTIONS. (lb/size) 1=69/6-0-0,4=10216-0-0,5=291/6-0-0 Max Horz 1 =1 95(LC 12) Max Uplift 4---105(LC 12), 5=-300(LC 12) Max G rav 1 =69(LC 1), 4--114(LC 17), 5=326(LC 17) FORCES. (lb) -Max. Comp./Max. Ten. -All forces 250 (lb) or less except when shown. TOPCHORD 1-2=-325/134 WEBS 2-5=-321/595 NOTES- I 1) Wind: ASCE 7-10; Vult=170mph (3-second gust) Vasd=132mph; TCDL=4.2psf; BCDL� 11; Exp D; Encl., GCpi=0.18; MWFRS (directional) and C-C Exterlor(2) zone;C-C for mal shown; Lumber DOL=1.60 plate grip DOL=1.60 2) Gable requires continuous bottom chord bearing. 3) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with E 4) * This truss has been designed for a live load of 20.Opsf on the bottom chord in all area, will fit between the bottom chord and any other members. 5) Provide mechanical connection (by others) of truss to bearing plate capable of wlthstan�, 4=105,5=300. 1 BRACING- TOPCHORD Structural wood sheathing directly applied or 6-0-0. oc purlins, except end verticals. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. :; h=33ft; B=53ft; L=65ft; eave=7ft; Cat. and forces & MWFRS for reactions iy other live loads. where a rectangle 3-6-0 tall by 2-0-0 wide Ing 100 lb uplift at joint(s) except at=lb) Walter P. Finn PE No.22839 MiTek USA, Inc. Fl. Cori 6634 69D4 Parke East Blvd. Tampa Fl. 33610 Date: November 12,2018 WARNING- Verify design parameters and REW NOTES ON THIS AND INCLUDED MITEK REFERANCE PAGE 111114473 rev. 1010312015 BEFORE USE. Design valid for use only with MiTek9 connectors. This design Is based only upon parameters shown, and Is for an Individual building component not a truss system. Before use, the building designer must verlfy the applicability of design parameters and properly Incorporate this design Into the overall building design. Bracing Indicated Is to prevent buckling of Individual truss web and/or chord members only. Additional temporary and permanent bracing MiTek' Is always required for stability and to prevent collapse with possible personal Injury and property dam6ge. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, seeANSVIP]l Quality CrIteda. DSB-69 and BCSI BuNdIng Camponent 6904 Parke East Blvd. Safety [riformatioravallable from Truss Plate Institute, 218 N. Lee Street Suite 312, Alexandria, VA 22314. Tampa, FL 33610 Job Truss Truss Type City Ply ACQ UAVISTA � T15560624 75575 N Half Hip 1 1 � Job Refen Chambers Truss, Inc., Fort Pierce, FL los Mar 11 2018 MiTek Industries, Inc. Mon Nov 12 09:39:35 2018 Page 1 8'1' ID:aNkrWfLwRDXTOZhc4Bay—yKyKq-OtLqd3PbzQwdol6YdU2kMFbwDx[XpS)o(bweLjSyJz76 7-8-6 13-0-0 14-4-0 11.-6.-I'l 7-8-6 5-3-10 1-4-0 14 3x4 = 5.00F12 6x8 15 2X3 11 3x6 4x4 = 6XB 4 5 7 6 6X8 =5X6 LOADING (psf) SPACING- 2�O CSI. DEFL. in (loc) I/defl Ud TCLL 20.0 Plate Grip DOL .�O 5 TC 0.65 Verl -0.07 8-12 >999 360 TCDL 15.0 Lumber DOL 1.25 BC 0.37 Vert(CT) -0.18 8-12 >957 240 BCLL 0.0 Rep Stress Incr YES WB 0.78 Horz(CT) 0.00 2 n/a , n/a BCDL 10.0 Code FBC2017/TP12014 Matrix -MS Wind(LL) 0.16 B-12 >999 240 LIUMBER- TOP CHORD 2X4 SP M 30 BOT CHORD 2X4 SP M 30 WEBS 2x4 SP No.3 OTHERS 2x4 SP No.3 REACTIONS. (lb/size) 2=749/0-8-0,13=607/0-3-8 Max Harz 2=582(LC 12) Max Uplift 2=-654(LC 12),13=-609(LC 12) Max Grav 2=778(LC 17),13=665(LC 17) FORCES. (lb) -Max. Comp./Max. Ten. -All forces 250 (lb) or less except when shown. TOP CHORD 2-3=-1014/805, 6-9=-622/461, 5-9=-622/461 BOTCHORD 2-8=-1 219/988, 7-8=-1 219/988 WEBS 3-8=-90/343, 3-7=-1041/1277,5-13=-693/870 Scale = 1:39.8 13 14 PLATES GRIP MT20 244/190 Weight: 82 lb FT = 20% BRACING- TOPCHORD Structural wood sheathing directly applied or 6-0-0 oc purlins, except end verticals. BOTCHORD Rigid ceiling directly applied or 5-11-13 oc bracing. NOTIES- 1 ) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-10; Vult=170mph (3-second gust) Vasd=132mph; TCDL=4.2psf; BCDL40psf; h=33ft; B=53ft; L=65ft; eave=7ff,.Cat. 11; Exp D; Encl., GCpi=0.18; MWFRS (directional) and C-C Exterion(2) -1-6-0 to 4-11-13, Interion(l) 4-11-13 to 13-0-0, Exterior(2) 13-0-0 to 13-10-12 zone;C-C for members and forces & MWFRS for reactions shown; 111 umber DOL=1.60 plate grip DOL=1.60 3) Provide adequate drainage to prevent water ponding. 1 4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 5) * This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. I 6) Bearing at joint(s) 13 considers parallel to grain value using ANSI/TP I I a, ivia to vial, i lormula. Building designer should verify capacity of bearing surface. 7) Provide mechanical connection (by others) of truss to bearing plate capable of withstan 01ing 100 lb uplift at joint(s) except at=lb) 2=654,13=609. Walter P. Finn PE No.22839 MiTek USA, Inc. Fl. Carl 6634 6904 Parke East Blvd. Tampa FL 33610 Date; November 12,2018 A WARNING -Vefify design parameters and READ NOTES ON THIS AND INCLUDED MTTEKREFERANCEPA I GE M11-7473 rev. I(IM2015 BEFORE USE. Design valid for use only with Mfrek@ connectors. This design Is based only upon parameters shown, and is for an Individual building component, not a truss system. Before use, the building designer must verity the applicability of design parameters and properly Incorporate this design Into the overall building design. Bracing Indicated Is to prevent buckling of Individual truss web and/or chord members only. Additional temporary and permanent bracing MiTek' Is always required for stability and to prevent collapse with possible personal Injury and property domdge. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, seeANSVTFI1 Quality Cifferla, DSB49 and BCSI Building Component 6904 Parke East Blvd. Safety Informatlonavailable from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.. Tampa, FL 33610 Job Tru s Truss Type City Ply ACQUAVISTA T15560625 75575 0 Half Hip 1 1 Job Reference (optional) Chambers Truss, Inc., Fort Pierce, FIL 8.130 s Mar 112018 MiTek Industries, Inc. Mon Nov 12 09:39:36 2018 Page I ID:aNkrWfLwRDXTOZhc4Bay—yKyKq-s3vCqPQDkj2UPShkABazuS86hLcZY?FgqaNvGvyJz75 7-8-4 14-4-0 -60 7-8-4 1 lioio 3-4-0 11--6--0 3x6 Scale = 1:32.3 4i4 5x8 14 2! 5.00 5-2 15 6x8 �� 3X5 = 1 2X3 11 3x8 = 3X4 11 7-8-4 14-4-0 7-8-4 3-4-0 Plate Off.;t. (X,Y)-- [2:0-1-2,Edgel, [5:0-1-8,0-3-01 LOADING (psf) SPACING- 2-0-0 CS1. DEFL. in (loc) I/cleff Ud PLATES GRIP TCLL 20.0 Plate Grip DOL 1.25 TC 0.60 Vert(LL) -0.07 8-12 >999 360 MT20 244/190 TCDL 15.0 Lumber DOL 1.25 BC 0.45 Vert(CT) -0.18 8-12 >923 240 BCLL 0.0 Rep Stress Incr YES WB 0.39 Horz(CT) -0.61 13 n/a n/a BCDL 10.0 Code FBC2017rrPI2014 Matrix -MS Wind(LL) 0.18 8-1 � >959 240 Weight: 83 lb FT = 20% LIUMBER- TOPCHORD 2X4 SP M 30 BOTCHORD 2X4 SP M 30 WEBS 2x4 SP No.3 OTHERS 2x4 SP No.3 REACTIONS. (lb/size) 2=749/0-8-0,13=607/0-3-8 Max Harz 2=505(LC 12) Max Uplift 2=-681 (LC 12), 13=-582(LC 12) Max Grav 2=778(LC 17), 13=633(LC 17) FORCES. (lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOPCHORD 2-3=-997/908, 3-4---433/448, 4-5=-353/438 BOTCHORD 2-8=-1214/956, 7-8=-12141956 WEBS 3-8=-89/300, 3-7=-828/1063, 5-7=-735/588, 5-13=-662[795 BRACING- TOPCHORD Structural wood sheathing directly applied or 6-0-0 oc puffins, except end verticals. BOTCHORD Rigid ceiling directly applied or 5-8-12 oc bracing. NOTES- 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-10; Vult=170mph (3-second gust) Vasd=132mph; TCDL=4.2psf; BCDL=3.opsf; h=33ft; B=53ft; L=65ft; eave=7ft; Cat. 11; Exp D; Encl., GCpi=O.l 8; MWFFIS (directional) and C-C Exterior(2) -1-6-0 to 4-11-13, In'terior(l) 4-11-13 to 11 -0-0, Exterior(2) 11-0-0 to 13-10-12 zone;C-C for members and forces & MWFRS for reactions shown; LiAber DOL=1.60 plate grip DOL=1.60 3) Provide adequate drainage to prevent water poncling. 4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any, other live loads. 5) * This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 1 6) Bearing at joint(s) 13 considers parallel to grain value using ANSVTPl 1 angle to grain forniula. Building designer should verify capacity of bearing surface. I 7) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding' 100 lb uplift at joint(s) except at=lb) 2=681,13=582. Walter P. Finn PE No.22839 MiTek USA, Inc. FL Cart 6634 6904 Parke East Blvd. Tampa FL 33610 Date: November 12,2018 WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MT`EK REFERANCE PAGE M, "w7473 rev. 1010312015 BEFORE USE. Design valid for use only with MiTel<0 connectors. This design Is based only upon parameters shown, and Is for an Individual building component, no a truss system. Before use, the building designer must verify the applicability of design parameters and properly Incorporate this design Into the ovqi�cil building design. Bracing Indicated Is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing MiTek' Is always required for stability and to prevent collapse with possible personal Injury and property damage. JFor general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, seeANSVJPII Quality Criteria. DS13-69 and BCSI Building Component 6904 Parke East Blvd. Safety Infarmatlanovallable from Truss Plate Institute, 218 N. Lee Street Suite 312, Alexandria, VA 22314. 1 Tampa, Fl- 33610 Job Truss Truss Type Cty Ply ACQUAVISTA T15560626 75575 P Half Hip 1 Job Reference (optional) Chambers Truss, Inc., Fort Pierce, FL 5.00 F-2 2X3 3 13 3X5 — �8.130 s Mar 11 2018 MiTek Industries, Inc. Mon Nov 12 09:39:37 2018 Page 1 ID:aNkrWfLwRDXTOZhc4Bay—yKyKq-KGTb2lRrUlAL1 cGxkv5CRghL—I—uHQtq2E7SoLyJz74 9-0-0 1 14-4-0 5-4-0 4x5 = 5x8 4 53x6 3Xs = 3X4 11 Scale = 1:28.7 7 12 1 9-0-0 1 5-4-0 Plate Offsets (X,Y)-- [2:0-0-6,Edgel, [5:0-1-8,0-3-01 1 LOADING (psf) SPACING- 2-0-0 CSI. DEFL. in (loc) I/clefl Ud PLATES GRIP TCLL 20.0 Plate Grip DOL 1.25 TIC 0.38 Vert(LL) -0.11 7-11 >999 360 MT20 244/190 TCDL 15.0 Lumber DOL 1.25 BC 0.38 Vert(CT) -0.26 7-11 >662 240 BCLL 0.0 Rep Stress Incr YES WB 0.56 Horz(CT) -0.02 12 n/a n/a BCDL 10.0 Code FBC2017[TP12014 M Wind(LL) 0.11 7-11 - >999 240 Weight: 75 lb FT = 20% LIUMBER- BRACING - TOP CHORD 2x4 SP M 30 TOPCHDRD Structural wood sheathing directly applied or 6-0-0 oc purlins, BOTCHORD 2x4 SP M 30 except end verticals. WEBS 2x4 SP No.3 BOTCHDRID Rigid ceiling directly applied or 6-0-5 oc bracing. OTHERS 2x4 SP No.3 REACTIONS. (lb/size) 2=749/0-8-0,12=607/0-3-8 Max Horz 2=429(LC 12) Max Uplift 2=-703(LC 12),12=-559(LC 12) Max Gram 2=773(LC 17),12=607(LC 1) FORCES. (lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOPCHORD 2-3=-1 06611146, 3-4=-698/719, 4-5=-634/726 BOTCHORD 2-7=-1386/1062 WEBS 3-7=-513/787, 5-7=-823/723, &1 2=-6371725 NOTES- 1) Wind: ASCE 7-10; Vult=l 70mph (3-second gust) Vasd=1 32mph; TCDL=4.2psf; BCDL= 3.Opsf; h=33ft; B=53ft; L=65ft; eave=7ft; Cat. 11; Exp D; Encl., GCpi=0.18; MWFRS (directional) and C-C Extedor(2) -1-6-0 to 4-11-13, Interion(l) 4-11-13 to 9-0-0, Exterior(2) 9-0-0 to 13-10-12 zone;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 2) Provide adequate drainage to prevent water ponding. 3) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 4) * This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 1 5) Bearing at joint(s) 12 considers parallel to grain value using ANSI/TPI 1 angle to grain formula. Building designer should verify capacity of bearing surface. I 6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) except at=lb) 2=703,12=559. Walter P. Finn PIE No.22839 MiTek USA, Inc. FL Cert 6634 6904 Parke East Blvd. Tampa FL 33610 Date: November 12,2018 WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERANCE PAGE M11-7473 rev. 10103)201S BEFORE USE. Design valid for use only with MITe1k@ connectors, This design Is based only upon parameters shown, an8 Is for an Individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and Oroperly incorporate this design Into the overall building design. Bracing Indicated Is to prevent buckling of Individual truss web and/or chord memberi only. Additional temporary and permanent bracing M!Tek' Is always required for stability and to prevent collapse with possible personal Injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, seeANSVFPII Quality Criteria, DSO-89 and BCSI Building Component 6904 Parike East Blvd. Sall"Ily Informatlonovallable from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.1 Tampa, Fl- 33610 IL Job Truss Truss Type Qty Ply ACQUAVII TA T15560627 75575 R. Half Hip Job Reference (optional) - unambers I russ, Inc., i--ort vierce, I-L 1-6 0 5.00F1-2 2 3X4 = 13 48 8.1au s mar 11 2olu mi I eK Industries, Inc. man NOV 12 U!J:3!J:37 2Q18 I'age I ID:aNkrWfLwRDXTOZhc4Bay—yKyKq-KGTb2lRrUlALlcGxkv5CRghHflzlHTiq2E7SoLyJz74 11-1-4 15-6-0 3)C4 4 LOADING (pso SPACING- 270-0 CS1. DEFL. in (loc) I/defl Ud TCLL 20.0 Plate Grip DOL 1.25 TC 0.59 Vert(LL) -0.08 6-7 >999 360 TCDL 15.0 Lumber DOL 1.25 BC 0.42 Vert(CT) -0.16 6-7 >999 240 BCLL 0.0 Rep Stress Incr YES WB 0.38 Hor7.(CT) -0.02 12 n/a n/a BCDL 10.0 Code FBC2017/TPI2014 Matrix -MS Wind(U-) 0.17 7-11 >999 240 LUMBER - TOP CHORD 2X4 SP M 30 BOT CHORD 2X4 SP M 30 WEBS 2x4 SP No.3 OTHERS 2x4 SP.No.3 REACTIONS. (lb/size) 2=801/0-8-0,12=660/0-3-8 Max Horz 2=353(LC 12) Max Uplift 2=-768(LC 12),12=-585(LC 12) Max Grav 2=813(LC 17),12=660(LC 1) FORCES. (lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOPCHORD. 2-3=-1129/1068,3-4=-1023/1117,6-8=-578/534,5-8=-578/534 BOT CHORD 2-7=-1 127/1023, 6-7=-903/723 WEBS 4-7=-370/374, 4-6"--789/1015,5-12=-665[784 Scale = 1:29.2 3x6 5 6xB 12 16 6 4x5 PLATES GRIP MT20 244/190 Weight: 74 lb FT = 20% BRACING - TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins, except end verticals. BOT CHORD Rigid ceiling directly applied or 6-0-5 oc bracing. NOTES- 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-10; Vult=170mph (3-second gust) Vasd=132mph; TC DL=4.2psf; BCDLj3.Opsf; h=33ft; B=53ft; L=65ft; eave=7ft; Cat. 11; Exp D; Encl., GCpi=0.18; MWFRS (directional) and C-C Exterior(2) -1-6-0 to 4-11--13j Interior(l) 4-11-13 to 7-0-0, Exterior(2) 7-0-0 to 15-0-12 zone;C-C for members and forces & MWFRS for reactions shown; Lumber [J,OL=1.60 plate grip DOL=1.60 3) Provide adequate drainage to prevent water ponding. 4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 5) * This truss has been designed for a live load of 20.Opsf on the bottom chord in all areaEl where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 1 6) Bearing at joint(s) 12 considers parallel to grain value using ANSI/TPI I angle to grain fo I rmula. Building designer should verify capacity of bearing surface. 1 7) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) except Ot=lb) 2=768,12=585. Walter P. Finn PE No.22839 MiTek USA, Inc. FL Carl 6634 6904 Parke East Blvd. Tampa FL 33610 Date: November 12,2018 A WARNING - Verify design parameters and READ NOTES ON THISAND INCLUDED MIrEKREFERANCEPA GIEMIP7473rev. IWO12015BEFORE USE. Design valid for use only with Mffek@ connectors. This design Is based only upon parameters sh . own, an� Is for an Individual building component not a truss system. Before use, the building designer must verity the applicability of design parameters andproperly incorporate this design Into the overall building design. Bracing Indicated Is to prevent buckling of Individual truss web and/or chord members only. Addifional temporary and permanent bracing MiTek' is always required for stability and to prevent collapse with possible personal Injury and property damobe. For general guidance regarding the fabrIcation, storage, delivery, erection and bracing of trusses and truss systems, seeANSVTPlI Quallty Cittedo, DSB-89 and BCS1 BuNdIng Component 6904 Parke East Blvd. Safaty Informatlomvallable from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandric', VA 22314,1 Tampa, FL 33610 Job Truss Truss Type Qty Ply CQU TA T15560628 75575 SFBB01 UnKnDwn 1 1 � Job RefeViSnce (optional) uriamners I russ, Inc., t-ort Pierce, l-L 0 2 8.i3u s mar 11 2uiB mi ieK Industries, Inc. MonNovlZU9:39:382018 Paget ID:aNkrWfLwRDXTOZhc4Bay—yKyKq-oSI zF5STFL]Bflr7iccRzIDbd9PI O—vzHus?KnyJz73 6-2_0 6-2-0 Scale = 1:12.3 3 NAILED 4 1P C? LOADING (psf) SPACING- 2-0-0 CS1. DEFL. in (loc) I/defl Ud PLATES GRIP TCLL 20.0 Plate Grip DOL 1.25 TC 0.06 Vert(LL) -0.00 1-2 >999 360 TCDL 15.0 Lumber DOL 1.25 BC 0.00 Vert(CT) -0.01 1-2 >999 240 BCLL 0.0 Rep Stress Incr NO WB 0.00 Horz(CT) 0.00 n/a n/a BCDL 10.0 Code FBC2017fTP12014 Matrix -MP Wind(LL) 0.01 1-2 >999 240 Weight: 4 lb FT = 20% LIUMBER- BRACING - TOP CHORD 2x4 SP M 30 TOPCHORD Structural wood sheathing directly applied or 6-2-0 oc pudins. BOTCHORD Rigid ceiling directly applied Or 10-0-0 oc bracing. REACTIONS. All bearings 0-3-8. (lb)- MaxUplift All uplift 100 Ild or less atjoint(s) 1, 4 except 2=-178(LC 8), 3= 135(LC 8) MaxGrav All reactions 250 lb or less atjoint(s) 1, 4, 2, 3 FORCES. (lb) -Max. Comp./Max. Ten. -All forces 250 (lb) or less except when shown. NOTES- 1) Wind: ASCE 7-10; Vultz�170mph (3-second gust) Vasd=132mph; TCDL=4.2psf; BCDL- 11; Exp D; Encl., GCpi=0.18; MWFRS (directional); Lumber DOL=11.60 plate grip DOL=1 2) Provide adequate drainage to prevent water ponding. 3) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with 1 4) * This truss has been designed for a live load of 20.Opsf on the bottom chord in all area will fit between the bottom chord and any other members. 5) Provide mechanical connection (by others) of truss to bearing plate capable of withstan 2=1 78, 3=1 35. 6) "NAILED" indicates 3-1 Od (0.1 48"x3") or 3-12d (0.1 48"x3.25") toe -nails per NDS guldlir 7) In the LOAD CASE(S) section, loads applied to the face of the truss are noted as front LOAD CASE(S) Standard 1) Dead + Roof Live (balanced): Lumber Increase=1.25, Plate Increase=1.25 Uniform Loads (plf) Vert: 1-4=-70 Concentrated Loads (lb) Vert: 2=-9(B) 3=-47(B) h=33ft; B=53ft; L=65ft; eave=7ft; Cat. iy other live loads. where a rectangle 3-6-0 tall by 2-0-0 wide ing 100 lb uplift at joint(s) 1, 4 except at=lb) or back (6). Walter P. Finn PE No.22839 MiTek USA, Inc. FL Cart 6614: 6904 Pak East Blvd. Tampa FIL 33810 DaW November 12,2018 ,&WARNING -Verify design parameters and READ NorEs ON rHIS AND iNcLuDED mrrEK REFERANCE PAGE 11111-7473 mv. 101012015 BEFORE USE. Design valid for use only with Mffek@ connectors. This design Is based only upon parameters shown, and Is for an Individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and'properly Incorporate this design Into the overall building design. Bracing Indicated Is to prevent buckling of Individual truss web and/or chord members only. Additional temporary and permanent bracing M!Tek' Is always required for stability and to prevent collapse with possible personal Injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, seeANSIMIJ Qualtly, CrIterla, DS111.89 and BCSI BuldIng Component 6904 Parke East Blvd. Safety Infounationovallable from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 223141 Tampa, FL 33610 Job Tru s Truss Type Qty Ply ACQUAVISTA T15560629 75575 V4 Valley 1 Job Chambers I russ, Inc., i-ort Vierce, F-L 3X4 5:� 5-oo F_2 s iviar 11 4U10 W11 1eK InUU5111US, 111U. IVIU11 NUV j4 uumazpaq i 4MO rdyu j ID:aNkrWfLwRD' )C'r"OjZuhc4Bay—yKyKq-Cli5u7UMYGgmWDZizl9BbWr4FMObDLePzs5gx6yJz7O 4-0-0 2-0-0 3x6 = 3X4 -- Scale = 1:7.5 LOADING (pso SPACING- 2-0-0 CS1. DEFL. in (loc) I/defl Ud PLATES GRIP TCLL 20.0 Plate Grip DOL 1.25 TIC 0.17 Vert(LL) n/a n/a 999 MT20 244/190 TCDL 15.0 Lumber DOL 1.25 BC 014 Vert(CT) n/a n/a 999 BCLL 0.0 Rep Stress Incr YES WB 0:00 Horz(CT) -0.00 3 n/a n/a BCDL 10.0 Code FBC2017/TP12014 Matrix-P Weight: 10 lb FT = 20% LUMBER- BRACING - TOP CHORD 2x4 SP No.3 TOP CHORD Structural wood sheathing directly applied or 4-0-0 oc purlins. BOTCHORD 2x4 SP No.3 BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS. (lb/size) 1=114/4-0-0,3=114/4-0-0 Max Horz 1 =-28(LC 10) Max Uplift 1 =-98(LC 12), 3=-98(LC 12) FORCES. (lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 1-2=-1 56/265, 2-3=-1 56/265 NOTES- 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-10; Vult=170mph (3-second gust) Vasd=132mph; TCDL=4.2psf; BCDL=3.Opsf; h=33ft; 13=53ft; L=65ft; eave=7ft; Cat. 11; Exp D; Encl., GCpi=O.l 8; MWFRS (directional) and C-C Exterior(2) zone;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) Gable requires continuous bottom chord bearing. 4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 5) * This truss has been designed for a live load Of 20.Opsf on the bottom chord in all areas �here a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and a.ny other members. 1 6) Provide mechanical connection (by others) of truss to bearing plate capable of withstandi Ing 98 lb uplift at joint 1 and 98 lb uplift at joint 3. Walter P. Finn PE No.22839 Mi rek USA, Inc. Fl. Cert 6634. 6904 Parke East Blvd. Tampa FL 33610 Date: November 12,2018 WARNING - Verify design parameters and READ NOTES ON THISAND INCLUDED MITEKREFERANCEPAGEIMII.7473 rev. 1MV2015BEFORE USE. Design valid for use only with MITek8 connectors, This design is based only upon parameters shown, and Is for an Individual building component not a truss system. Before use, the building designer must verlty the applicability of design parameters and pr6perly Incorporate this design Into the overall building design, Bracing Indicated Is to prevent buckling of Individual truss web and/or chord members only. Additional temporary and permanent bracing MiTdk' Is always required for stability and to prevent collapse with possible personal Injury and property dcmage� For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, seeANSVrpll Quality Cdtoria, DS13-89 and BCSI Buldtng Component 6904 Parke East Blvd. Safety Inforynationavallable from Truss Plate Institute, 218 N. Lee Street Suite 312, Alexandria, VA 22314. Tampa, FL 33610 a I Job Truss Truss Type City Ply ACQUAVISTA T15560630 75575 VB Valley 1 1 Job Reference (optional) Chambers Truss, Inc., Fort Pierce, FL 8.130 a Mar 11 2018 MiTelk Industries, Inc. Mon Nov 12 09:39:42 2018 Page 1 ID:aNkrWfLwRDXTOZhc4Bay—yKyKq-hDHU5TV — JZod7N8uXSgN8jO7dmk7yn?ZCWqDTYyJz7? 4-0-0 8-0-0 1 Scale = 1:14.6 3X4 2x3 III 3X4 LOADING (pso SPACING- 2-0-0 CS1. I DEFL. in (loc) Vdefl Lid PLATES GRIP TCLL 20.0 Plate Gdp DOL 1.25 TC 0.70 Vert(LL) n/a n/a 999 MT20 244/190 TCDL 15.0 Lumber DOL 1.25 BC 0.18 Vert(CT) n/a n/a 999 BCLL 0.0 Rep Stress Incr YES WB 0.12 Horz(CT) 0.00 3 n/a n1a, BCDL 10.0 Code FBC2017fTP]2014 Matrix-P I Weight: 24 lb FT = 20% LUIMBER- BRACING - TOP CHORD 2x4 SP No.3 TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins. BOT CHORD P_x4 SP No.3 BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. OTHERS 2x4 SP No.3 I REACTIONS. (lb/size) 1=14618-0-0,3=146/8-0-0,4=297/8-0-0 Max Horz 1 =-72(LC 10) Max Uplift 1=-147(LC 12), 3=-147(LC 12), 4=-209(LC 12) Max Grav 1=147(LC 17), 3=156(LC 18), 4--2911) FORCES. (lb) -Max. Comp./Max. Ten. -All forces 250 (lb) or less except when shown. WEBS 2-4---248/409 NOTES- 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-10; Vult= ' 170mp� (3-second gust) Vasd=132mph; TCDL=4.2psf; BCDL=3.Opsf; h=33ft; B=53ft; L=65ft; eave=7ft; Cat. 11; Exp D; Encl., GCpi=o.l 8; MWFRS (directional) and C-C Exterior(2) zone;C-C for members and forces & MWIFFIS for reactions shown; Lumber DOL=1.60 plate grip DOL=11.60 3) Gable requires continuous bottom chord bearing. 4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 5) * This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord ai'id any other members. 6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 1147 lb uplift at joint 1, 147 lb uplift at joint 3 and 209 lb uplift at joint 4. Walter P. Finn PE No.22839 MiTak USA, Inc. FL Cott 6634 6904 Parke East Blvd. Tampa FL 33810 Date: November 12,2018 WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERANCE PAGE M11-7473 rev. 1010312015 BEFORE USE. Design valid for use only with MiTek0 connecfors. This design Is based only upon parameters shown, and Is foran Individual building component not a truss system. Before use, the building designer must verity the applicability of design parameters and properly Incorporate this design Into the overall building design. Bracing Indicated Is to prevent buckling of Individual truss web and/or chord members only,1 Additional temporary and permanent bracing MiTdk' Is always required for stability and to prevent collapse with possible personal Injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, seeANSVTP11 Quality Cifferia,11I)SIII-89 and BCS1 aluldling Component 6904 Parke East Blvd. Safety trifoonatIonovailable from Truss Plate InstItute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314. Tampa, FL 33610 Job Truss Truss Type Qty Ply ACQUAVISTA T15560631 75575 V12 Valley 1 Job Reference (optional) unamuers i russ, inc., r-on merce, r-L 5.00 F1-2 0 3X4 �� b.iuu s mar i i zuib mi I eK Industries, Inc. Mon NOV 12 09:39:39 2018 Page 1 ID:aNkrWfLwRDXrOZhc4Bay—yKyKq-GebLTRT6OeQ2GvQJsK7gW5mhiYd)dPG6WYcZsEyJz72 1 12-0-0 6-0-0 1 Scale = 1: 18.9 5x6 2 4 11 12-0-0 LOADING (psf) SPACING- 2-0-0 CS1. DEFL. in (loc) I/defl Ud TCLL 20.0 Plate Grip DOL 1.25 TC 0.36 Vert(LL) n1a. We 999 TCDL 15.0 Lumber DOL 1.25 BC 0.47 Vert(CT) n/a n/a 999 BCLL 0.0 Rep Stress Incr YES WB 0.19 Horz(CT) 0.00 3 n/a n/a BCDL 10.0 Code FBC20171TP12014 Matrix-S LIUMBER- TOP CHORD 2X4 SP M 30 BOT CHORD 2x4 SP No.3 OTHERS 2x4 SP No.3 REACTIONS. (lb/size) 1=211/12-0-0,3=211/12-0-0,4=527/12-0-0 Max Horz 1 =-1 17(LC 10) Max Uplift 1=-204(LC 12), 3=-204(LC 12), 4---404(LC 12) Max Grav 1=216(LC 17), 3=233(LC 18), 4=527(LC 1) FORCES. (lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. WEBS 2-4---3991624 NOTES- 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-10; Vult=170mph (3-second gust) Vasd=132mph; TCDL=4.2psf; BCDL= 11; Exp D; Encl., GCpi=0.18; MWFRS (directional) and C-C Exterior(2) zone;C-C for mer shown; Lumber DOL=11.60 plate grip DOL=1.60 3) Gable requires continuous bottom chord bearing. 4) This truss has been designed for a 10. , 0 psf bottom chord live load nonconcurrent with a 5) * This truss has been designed for a I ' ive load of 20.Opsf on the bottom chord in all areaE will fit between the bottom chord and any other members. 6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanc 1=204,3=204,4=404. 3 3X4 Z�- PLATES GRIP MT20 244/190 Weight: 38 lb FT = 20% BRACING - TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. ; h=33ft; B=53ft; L=65ft; eave=7ft; Cat. and forces & MWFRS for reactions other live loads. iere a rectangle 3-6-0 tall by 2-0-0 wide 1100 lb uplift at joint(s) except at=lb) Walter P. Finn PE No.22839 MiTek USA, Inc, FL Cart 6634 6904 Parke East Blvd. Tampa FL 33610 Date: November 12,2018 ,& wARNiNr- Verify design parameters and READ NOTES ON THIS AND INCLUDED MfTEKREFERANCE PAGE' MIP7473rev. 10/0&2015 BEFORE USE. Deslgnvolid foruse onlywith MITek0 connectors. ThIsclesign Is based onlyupon parameters shown, andilsforan Individual building component, not a truss system. Before use, the building designer must verity the applicability of design parameters and properly Incorporate this design Into the overall building design. Bracing Indicated Is to prevent buckling of individual truss web and/or chord members!only. Additional temporary and permanent bracing Mffbk' Is always required for stability and to prevent collapse with possible personal Injury and property damage. For general guidance regarding the . fabrication, storage, delivery, erection and bracing of trusses and truss systems, seeANSVTPI1 Qual CrIt do, DSO-89 and BCSI Building Component HT Safety Informationavallable from Truss Plate Institute, 218 N. Lee Street Suite 312, Alexandria, VA 22 14. 1 6904 Parke East Blvd. Tampa, Fl- 33610 Job Tru s Truss Type Qty Ply ACQUAVISTA T15560632 75575 V16 Valley 1 al) Chambers Truss, Inc., Fort Pierce, FIL 8.130 s Mar11 2018 MiTek Industries, Inc. Mon Nov 12 09:39:402018 Page 1 ID:aNkrWfLwRDXTOZhc4Bay—yKyKq-kr9ignTknyYvu3_�VPlev3[Jivy2MUr—GICL6PgyJz71 8-0-0 16-0-0 8-0-0 B-0-0 Scale = 1:25.c 4x4 LOADING (psf) SPACING- 2-00 CS1 - I DEFL. in (loc) I/defl Lid TCLL 20.0 Plate Grip DOL 1 �5 TC 0.97 Vert(LL) n/a n/a 999 TCDL 15 .0 Lumber DOL 1.25 BC 0.14 Vert(CT) n/a n/a 999 BCLL 0.0 Rep Stress Incr YES WB 0.22 Horz(CT) 0.00 5 n/a n1a BCDL 10.0 Code FBC2017/TP12014 Matrix-S LUMBER - TOP CHORD 2x4 SP No.3 BOT CHORD 2X4 SP M 30 OTHERS 2x4 SP No.3 REACTIONS. All bearings 16-0-0. (lb) - Max Harz 1 =-1 61 (LC; 10) MaxUplift All uplift 100 lb or less atjoint(s) except 1=-153(LC 12), 12). 8=-532(LC 12) PLATES GRIP MT20 244/190 Weight: 57 lb FT = 20% RACING- DPCHORD Structural wood sheathing directly applied� OT CHORD Rigid ceiling directly applied or 6-0-0 oc bracing. 12), 7=-1 12(LC 1), 6=-532(LC MaxGeav All reactions 250 lb or less atjoint(s) 1, 5, 7 except 6=577(LC 181., 8=578(LC 17) FORCES. (lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 2-3=-120/271, 3-4=-120/271 WEBS 3-7=-311/130, 4-6=-4381734, 2-8=-438f734 NOTIES- 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-10; Vult=1 70mph (3-second gust) Vasd=1 32mph; TCDL=4.2psf; BCDL=3.Obsf; h=33ft; B=53ft; L=65ft; eave=7ft; Cat. 11; Exp D; Encl., GCpi=0.18; MWFRS (directional) and C-C Exterior(2) 0-8-12 to 7-2-9, Interi , or(l) 7-2-9 to 8-0-0, Extedor(2) B-0-0 to 14-5-13 zone;C-C for members and forces & MWFRS for reactions shown; Lumber DOL .=l.'60 plate grip DOL=1.60 3) Gable requires continuous bottom chord bearing. 1 1 4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 5) * This truss has been: designed for a live load of 20.Opsf on the bottom chord in all areas win 'ere a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 153 lb uplift at joint 1, 153 lb uplift at joint 5, 112 lb uplift at joint 7, 532 lb uplift at joint 6 and 532 lb uplift at joint 8. 1 Walter P. Finn PE No.22839 MiTek USA, Inc. FL Carl 6634. 6904 Parke East Blvd. Tampa FL 33610 Date: - Novembet 12,2018 &WARNING -Verify design parameters and READ NOTES ON,THIS AND INCLUDED MITEK REFERANCE I M11=7473 rev. 10/03,2015 BEFORE USE. .pAGE Design valid for use only with Mrrek@ connectors, This design Is based only upon parameters shown, and Is for Ion Individual building component not a truss system. Before use, the building designer must verify the applicability of design parameters,and properly Incorporate this design Into the overall building design. Bracing Indicated Is to prevent buckling of Individual truss web and/or chord members only. �Addltlonol temporary and permanent bracing MR&W Is always required for stability and to prevent collapse with possible personal Injury and property damage. For, general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see^NSVTPII Qual' Criteria, DSII-89 and BCSI Building Componont 6904 Parke East Blvd. Safety Informationavollable from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 2 2�1 4. i Tampa, FL 33610 Symbols PLATE LOCATION AND ORIENTATION 14 /; Center plate on joint unless x, y -13 offsets are indicated. Dimensions are in ft-in-sixteenths. Apply plates to both sides of truss and fully embed teeth. 0-111gi JF For 4 x 2 orientation, -locate plates 0-1/0frorn outside edge of truss. This symbol indicates the required direction of slots in connector plates. *Plate location details available in MiTek 20/20 software or upon request. PLATE WE __Fs —the—plate-_ Tf�e first climenskon 4 x 4 width measured perpendicular to slots. Second dimension is the length parallel to slots. LATERAL BRACING LOCATION Indicated by symbol shown and/or by text in the bracing section of the output. Use T or I bracing if indicated. BEARING Indicates location where bearings (supports) occur. Icons vary but reaction section indicates joint number where bearings occur. Min size shown is for crushing only. Industry Standards: ANSI/TP11: National Design Specification for Metal Plate Connected Wood Truss Construction. DSB-89: Design Standard for Bracing. BCSI: Building Component Safety Information, Guide to.Good Practice for Handling, Installing & Bracing of Metal Plate Connected Wood Trusses. 0 CL 0 0 Numbering System &4-8 dimensions shown in ft-in-sixteenths I (Drawings not to scale) 2 3 TOP CHORDS . BOTTOM CHORDS 8 7 6 5 JOINTS ARE GENERALLY NUMBERED/LETTERED CLOCKWISE AROUND THE TRUSS STARTING AT THE JOINT FARTHEST TO THE LEFT. CHORDS AND WEBS ARE IDENTIFIED BY END JOINT NUMBERSAETTERS. PRODUCT CODE APPROVALS ICC=ES-Reports:— -- - _' — ESR-1 311, ESR-1 352, ESR1 988 ER-3907, ESR-2362, ESR-1397, ESR-3282 0 0� 0 0 a_ 0 Trusses are designed for wind loads in the plane of the truss unless otherwise shown. Lumber design values are in accordance with ANSI/TIPI 1 section 6.3 These truss designs rely on lumber values established by others. @ 2012 M!Tek@) All Rights Reserved mm W1 0 M'iTek 0 MiTek Engineering Reference Sheet: MII-7473 rev. 10/03/2015 AL General Safety Notes Failure to Follow Could C., ause Property Damage or Personal Injury 1. Additional stability bracing for truss system, e.g. diagonal or X-bracing, is always required. See BCSI. .2. Truss bracing must be designed by an engineer. For wide truss spacing, individual lateral braces themselves may require bracing, or alternative Tor I bracing should be considered. 3. Never exceed the design loading shown and never stack materials on inadequately braced trusses. 4. Provide copies of this truss design to the building designer, erection supervisor, property owner and all other interested parties. 5. Cut members to bear tightly against each other. 6. Place plates on each face of truss at each joint and embed fully. Knots and wane at joint locations are regulated by ANSI/TPI 1. 7. Design assumes trusses will be suitably protected from the environment in accord with ANSI/TPI 1. 8. Unless otherwise noted, moisture content of lumber shall not exceed 19% at time of fabrication. 9. Unless expressly noted, this design is not applicable for — use with fire retard-Ont-preseLvative-treated, or green -lumber. 10. Comber is a non-structural consideration and is the responsibility of truss fabricator. General practice Is to camber for dead load deflection. 11. Plate type, size, orientation and location dimensions indicated are minimum plating requirements. 12. Lumber used shall be of the species and size, and in all respects, equal to or better than that specified. 13. Top chords must be sheathed or purlins provided at spacing indicated on design. 14. Bottom chords require lateral bracing at 10 ft. spacing, or less, if no ceiling is installed, unless otherwise noted. 15. Connections not shown are the responsibility of others. 16. Do not cut or after truss member or plate without prior approval of an engineer. 17. Install and load vertically unless Indicated otherwise. 18. Use of green or treated lumber may pose unacceptable environmental, health or performance risks. Consult with project engineer before use. 19. Review all portions of this design (front, back, words and pictures) before use. Reviewing pictures alone Is not sufficient. 20. Design assumes manufacture in accordance with ANSI/TPI 1 Quality Criteria.