Loading...
HomeMy WebLinkAboutBUILDING PLAN PAGE 1-10RMSIONS BY DATE A permit sets GS 10.4.2018 A Ist Building Comments GS 3.12.2019 PICKET SPACING TO REJECT 4" DIA. SHERE NOTE: ALL FASTENERS FOR RAIL ATTACHMENTS TO BE STAINLESS STEEL [110011 Ffl 111111% k1FA I ILI [918 KC1111111MI :4 911111101:1111111 IFTAIU 4 Al 4" MIN EDGE DISTANCE 4" < 4 4 TOP CAP ON 2"xZXV TUBE Y2" DIA SOL ALUM ROD (TYP.) 2" x 2" PICKET 2" x 2" SO PICKET PICKET SPACING TO REJECT 4" DIA. SHERE NOTE: ALL FASTENERS FOR RAIL ATTACHMENTS TO BE STAINLESS STEEL 3/4 V-0" 1 04 1 ALUMINUM GUARD DETAIL RAILING POST (REFER TO SHOP DRAWINGS FOR SIZE & LOCATIONS) MIN POST EMBEDMENT = 4" 3 1/4" DIA x 4" DEEP HOLE INTO CONCRETE, FILL HOLE w/ EPDXY BONDING/GROUTING ADHESIVE (SIKADUR 32 HI -MOD) 4� 07 1 EXTERIOR RAILING ATTACHMENT RECOMMENDED WATERPROOFING BE PROVIDE AT THE COLD JOINT BETWEEN THE DECK AND THE CMS TO PREVENT WATER INTRUSION. RECOMMEND WATERPROOFING BE PROVIDED V BEYOND THE SLIDING GLASS DOOR PERIMETER SEALANT TOWARD THE INTERIOR; 1" ON THE DECK OUT FROM THE RETURN; 2" CUTAWAY FROM THE CMU, AND SIX TO EIGHT INCHES UP THE EXTERIOR FACE OF THE WALL RECOMMENDED 3/4" X 3/4" SILICONE CANT PRIMER. IF REQUIRED CANT BEAD TO BE PROVIDED AFTER STUCCO AT THE JUNCTION OF THE CONCRETE SLAB AND THE EXTERIOR FACE. CANT BEAD TO TIE INTO THE SLIDING GLASS DOOR PERIMETER SEALANT. 1" BEYOND SLIDING GLASS DOOR PERIMETER SEAL CONCRETEBLOCK STUCCO--,,,.. SLIDING GLASS DOOR ��rFRAME SILL TOP CAP 2"xZ' TL Y2" DIA ALUM (TYP.) �3%" METAL RUNNER 2X4 NAILED TO--X TRACKS (25 ga) TOP & BOT FIL R TRUSSES OOR TRUS E ((2) 161 each t2uss) No. 6 x 1 " GALV SCREWSA� 32" O/C TO TOP RUNNER 1 1/2" x 2" SQ ____�3%" METAL STUDS PICKET (25 9a) @ 16" O/C NORMAL MATERIALS DESIGN FLOOD 211 x 2" S --- ELEVATION (DFE) PICKET SEE PLANS jl� FLOOD PROOF MATERIALS (CLASS 4 OR 5 PER FEMA No. 6 x I" GALV SCREWS TECHNICAL BULLETIN #2) @ 32" O/C TO BOT PLATE 3/4 1 THIS DESIGN ALLOWS THE METAL FRAMED WALL TO BREAKAWAY FROM THE PERMANENT TOP & P.T. 2x4 w/ 1/4" x 3" BOT 2x4 RUNNERS WITHIN THE 10-20 PSF LOADIN, CORROSION RESISTANT RANGE WITHOUT HARM TO THE ELEVATED PORTI TAPCONS @ 16" O/C OF THE BUILDING OR SUPPORTING FOUNDATION INTERIOR NON -BEARING -011 MIDEM CAP @ D3 11/2 :WEL POST BREAKAWAY WALL CONSTRUCTION RDWOOD BALUSTERS STANDING SEAM METAL ROOF ACED TO REPECT (.032 ALUM 5V CRIMP) DIAMETER SPHERE OVER VERSASHIELD ON PEEL & STICK MEMBRANE OVER 30# FELT TIN TAGGED TO APA 40/20 19/32" EXPOSURE 1 PLYWOOD NEWELPOS� SEE ANCHOR SCHEDULE ON STRUCTURAL PLANS FOR ROOF TIE DOWNS NTS 03 WOOD BALCONY RAILING DETAIL 3/4" V-10' GRASPABLE TOP RAIL PER N.F.P.A. 101 5-2.2.4.5 (C) R 311.5.6 HANDRAILS Sl- ALL BE PROVIDED ON AT LEAST 1 SIDE OF EACH STAIRS & SHALL BE CONTINUOUS FOR THE FULL LENGTH OF THE FLIGHT HARDWOOD BALUSTERS SPACED TO REJECT Z//�4" DIAMETER SPHERE CANT BEAD—� . . . . . . . . . . . . . . . . WOOD STAIRS I�HARDNOOD MEMBRANE WATERPROOFING /4" RECESS DECORA E HARDWOODSKIRTB RD RISEP S VULKEM TRAFFIC COATING TO BE USED ON BALCONY SURFACES UPPER STAIR - RISE=7.09", RUN=1 1" LOWER STAIR - RISE=6.95", RUN=11" 06 WATERPROOFING BALCONY NTS 02 STAIR RAIL DETAIL 3/4 1 NON-SKID FLOORING ON EPDXY BASED SETTING MATERIAL & GROUT OVER TRAFFIC COATING META. RUNNER (NO PHOSPHATE BASED MORTAR) FOR FIRE RATED & ADJACENT WALLS:_j TRACKS ("5 ga) TOP & BOT TOP & BOT RUNNERS TO BE FASTENED TO TRAFFIC COATING CEILING & FLOOR @ MAX 24" O/C w/ 5/8" EMBED NAILS OR SELF TAPPING SHEET BULLNOSE METAL SCREWS FOR METAL TO METAL EDGE 39/8" ME STUDS (25 ga) @ 24" O/C zi < < WATER DRIP — GROOVE SMOOTH STUCCO FINISHED BALCONY 05 1 BALCONY EDGE DETAIL LOP— BEAM 0+41-4"A.F.F. Fi SEESHEETA802F OR 8 (qA802 TRUSS END DETAILS 12PVO EAM&1STFLOOR ELE O�V 8"x16" BOND BEAM­--� (SEE STRUCTURAL PLANS) FILLED CELLS w/ VERT. DOWELS (SEE STRUCTURAL PLANS FOR SIZES & LOCATIONS) 3/4" RECESS GARAGE/LOBBY @ \-w ELEV`-14'-10'7­11'-0" GRADE VARIES MIN R-20 1/2 Ib. PER CUBIC FOOT SPRAY APPLIED OPEN CELLED FOAM INSULATION THAT PASSES ACC 377 APPENDIX'X'WITHOUT A COATING 12 5 _AA :0 1-90 _D T I�A nnKI7 0 ON soM IN Uvirms 1 IN I 0 0 0 IN ME NJ 0! 5/8" GYP E CARD w/ A LEVEL 4 F NISH OR 518" DURCCK @ WET AREAS NOTE: —BATT INSULAT:ON FOR WALLS P.T. 2x4 FRAMING AROUND BETWEEN CONDITIONED and ALL SHOWER OPENINGS UNCONDITION ED SPACES, AT OPT. LOCATIONS FOR SOUND- GENERAL NOTE SPECIFICATIONS: SEE PLANS =ALL CONCRETE SHALL BE OCEAN MIX =ALL NAILS SHALL BE GALVANIZED mALL FASTENERS SHALL BE STAINLESS STEEL NTS 01 INTERIOR FRAME WALL (NON BEARING) If 1-011 1 1/2 1 D1 � TYPICAL 2-STORY WALL SECTION v METAL FRAMING @ SOFFITS P.T. 1x3 FIRESTOP CONT. ITIF5/8" GYP BOARD OVER R4.1 FI-FOIL INSULATION /-STAPLED TO P.T. 1x2 FURRING @ 24" O/C P.T. 1x4 CONT, L 14 SEE STRUCTURAL PLANS hi FOR PILING, GRADE BEAMS, A FOUNDATION DETAILS A INTERIOR WALL & CEILING FINISH NOTES: 1. ALL INTERIOR WALL & CEILING FINISHES TO COMPLY wl FBC 2017 R302,9 FOR FLAME SPREAD & SMOKE DEVELOPED INDEX. 2. FLAME SPREAD INDEX NOT TO EXCEED 200. 3, SMOKE DEVELOPED INDEX NOT TO EXCEED 450. INSULATION NOTES: 1. ALL INSULATION TO COMPLY wl FBC 2017 R302.10 FOR FLAME SPREAD & SMOKE DEVELOPED INDEX. 2. FLAME SPREAD INDEX NOT TO EXCEED 25. 3. SMOKE DEVELOPED INDEX NOT TO EXCEED 450. STANDING SEAM METAL ROOF (.032 ALUM 5V CRIMP) OVER VERSASHIELD ON PEEL & STICK MEMBRANE OVER 30# FELT TIN TAGGED TO APA 40/20 19/32" EXPOSURE 1 PLYWOOD SEE ANCHOR SCHEDULE ON STRUCTURAL PLANS FOR ROOF TIE DOWNS P F LO _-N _OPEAM g+23 A.F.F. SEE SHEET A802 FOR--/ TRUSS END DETAILS F4P F BEAM & 2ND FLOOR 3 -0" A. F.F. 8"x16" BOND BEAM----'� (SEE STRUCTURAL PLANS) PC �EAM & 1ST FLOOR E 2LE ZO 0 8"x16" BOND BEAM----'� 'LIED (SEE STRUCTURAL PLANS) �ES FILLED CELLS w/ VERT. DOWELS (SEE STRUCTURAL PLANS FOR SIZES & LOCATIONS) 3/4" RECESS GARAGE/LOBBY (a. \-w ELEV-14'-10"/-1j'-0" GRADE VARIES GENERAL NOTE SPECIFICATIONS: -ALL CONCRETE SHALL BE OCEAN MIX -ALL NAILS SHALL BE GALVANIZED -ALL FASTENERS SHALL BE STAINLESS STEEL MIN R-20 1/2 lb. PER CUBIC FOOT SPRAY APPLIED OPEN CELLED FOAM INSULATION THAT PASSES ACC 377 APPENDIX'X'WITHOUT A COATING 12 F - ir I rn - c �'8" GYPSUM BOARD CLG ATTACHED rO BOT CHORD OF TRUSSES P.T. 1x3 FIRESTOP CONT MIN 8"x8" BOND BEAM (SEE STRUCTURAL PLANS) A A -A 0*1 N 00 jai 1-ma MINME in in unf_.... IMIN 91 KWAASTITA I I --------- ---- METAL FRAMING @ SOFFITS P.T. 1x3 FIRESTOP CONT. A M� -A 0 0 N 0 If 3/4 V-10" I D2 I TYPICAL 3-STORY WALL SECTION METAL FRAMING @ SOFFITS P.T. 1x3 FIRESTOP CONT. 5/8" GYP BOARD OVER R4.1 FI-FOIL INSULATION STAPLED TO P.T. 1x2 FURRING @ 24" O/C T. 1x4 CONT. — --- — — — — — — — — — 1=1 1=1 hl 4, SEE STRUCTURAL PL 1. ` 11, FOR PILING, GRADE I A FOUNDATION DETAIL r A LIED ;ES LIED ES 4-.) U No 0) 4--a 4-j U 4.3 U �`A g 4� U) MUMMER= z '0 1 Am, :7, *40 �rll z Ali" Job No. 1802011 1A -001.1105 FIRM -AM FL 801 It 1-011 3/4 1 00 REWSIONS BY DATE 0 � permft sets GS 10.42018 GALV METAL DRIF OVER P.T. U2 ON 2xi CYPRESS FASCIA vy (2) 16d TO EACH TRUS! MIN SELF EMU 4 CY 0 (D 0-1 z Auks" Job No, 1802011 FV�0011105 MM-MX-3379 I A802 CASING BY INTERIOR 2X6 P.T. BUCK W/ 1/4" DIA. x 00 REVBIONS BY IC permit sets GS 1 OR OWNER 1-3/4" EMBED. @ 12" O.C., 6" E.E. WOOD CASING, BY OWNER TOM lX6 P.T. NAILER PROVIDE 2-1/4" MASONRY DRYWALL SEE EDGE DISTANCE METAL STUD PARTITION w/ PROVIDE SHIMS AS REQUIRED WALL SECTIONS JAMB EXTENSION AS NEEDED GYPSUM WALLBOARD (SEE WALL TYPES) METAL STUD PARTITION w/ WOODDOOR (SEE FLOOR PLAN) 71 1 ATTACH DOOR FRAME BLOCKING AS REQ'D 0 GYPSUM WALLBOARD fS ;EE WALL TYPES) WOOD CASING, PAINT GRADE 6 9 PER LATEST NOA PRODUCT APPROVALS PROVIDE SHIMS AS DOOR STOP A \9 (VERIFY W/ OWNER) T� IMPACT RATED EXTERIOR REQUIRED PRE -HUNG WOOD DOOR FRAME DOOR (NOT FRENCH) PER WOOD CASING BY OWNER DOOR STOP BEYOND .,EXTEND LATEST NOA PRODUCT WATERPR' 1.4 APPROVAL PRE -HUNG WOOD DOOR FINISH FLOOR VARIES BY STONE OR BRICK FRAME ROOM (VERIFY SPEC's w/ OWNER) THRESHOLD BLOCKING AS REQ'D WOODDOOR NOTES: CONCRETE FLOOR SLAB VIWATTERPROOFING VULKEM SEALANT ON (SEE FLOOR PLAN) PRE -HUNG WOOD (SEE FOUNDATION PLAN) BACK SIDE & FRONT I.VERIFY W/ OWNER IF SOUND DOOR FRAME INSIDE& OFBUCK NOTES: INSULATION WILL BE REQUIRED. FACE OF OPENINGS, SEE SPECS. STUCCO RETURN l.VERIFY W/ OWNER IF SOUND WOOD DOOR 2. VERIFY HINGE SIDE w/ FLOOR PLAN. (SEE DOOR SCHEDULE) NOTES: INSULATION WILL BE REQUIRED. l.VERIFY w/ OWNER IF SOUND STUCCO W/ 2. VERIFY HINGE SIDE FLOOR PLAN. SMOOTH FINISH wl INSULATION WILL BE REQUIRED. 2. VERIFY HINGE SIDE w/ FLOOR PLAN. FILLED CELL OR N POURED COL., SEE R STRUCT. *CAULK AS REQUIRED 1Y2"=V-0" 'CAULK AS REQUIRED lY2"=l'-0" *CAULK AS REQUIRED 1)/2.'=V-0" UVP. WITIEROOR DOOR MEAD DEVAUL TYP. JNTERHOR DOOR J,%NB DE7A[L TYP. gHTEROOR DOOR THRIESHOLD 0177AHL tid DOOR OUTSM01M J&HB DIMM R INIJIUA 1 E6 6KII NOTES: 8" 1. CAULKING, SEALANT, ADHESIVE, STUCCO W/ PRECAST LINTEL OR POUREDBEAM CMU WALL OVER PRECAST PLASTER w/ SMOOTH LINTEL OR POURED CONC, FINISH BEAM, SEE STRUCT. STUCCO W/ PRECAST LINTEL OR POURED BEAM PRECAST LINTEL OR P POURED BEAM (SEE STRUCTURAL OVERLAP AND WALL JOINTS TO FORM AIR BARRIER. SMOOTH FINISH 'S 2. THESE PRINCIPLES ARE DRYWALL SEE WALL SECTIONS 2X6 P.T. BUCK W1 4" TAPCONS W/ WASHERS 1%" STUCCO w/ WATERPROOFING INSIDE I I . 0 & 0 SMOOTH FINISH ALSO APPLICABLE TO DOOR 0 EMBED @ 8" O.C. MAX, 2" WEATHERPROOFING. '�-MOISTUt�PRR 'ER WATERPROOFING INSIDE & FACE OF OPENINGS, SEE 00 �za SMOOTH FINISH FROM CORNER z FACE OF OPENINGS, SEE SPECS. no DRYWALL SEE zR WALL SECTIONS w : a � t.4 z OVERLP P DIRECT OM 0 MOISTURE AW/ M SPECS. IX6 P.T. NAILI ER W 4 STONE SURROUND IF no A w W IX6 P.T. NAILER WATERPROOFING INSIDE & LL I - DF 0�0 DRYWALL SEE W WALL SECTIONS 9 STRUCTURE/ FRkyA=MIN Lu 3Y4' APPLICABLE �zo wx FACE OF OPENINGS, SEE z w VULKEM SEALANT ON CASING BY INTERIOR SPECS. J17 4 ff, Z BACK SIDE & FRONT OR OWNER La L w 1_1y ui lX6 P.T. NAILER CI <11 OFBUCK 6 CASING BY INTERIOR OR OWNER CASING BY INTERIOR OR \-HEAD CASINGI TRIM JAMB EXTENSION AS OWNER N. NEEDED CORNERBEAD STANDARD 2" TRACK, 2X4 P.T. BUCK W/ Y4" TAPCONS JAMB EXTENSION AS NEEDED STONESURROUND 2X6 P.T. BUCK W/ 1/4" TORSION SPRING STONE SURROUND & IY4" EMBED @ 8" O.C. MAX, 2" FROM CORNER 6" RETURN OTIONAL DIA. x 1-3/4" EMBED. @ 12" O.C., 6" E.E. DRIP KERF IN OPERATED O.H. RETURN,SEE ELEVATIONS 2X6 RIPPED P.T. BUCK W1 1/4" DIA. x 1-3/4" EMBED. @ 12" O.C., MiN. (SEE ELEVATIONS) PROVIDE 2-1/4" STUCCO RETURN GARAGE DOOR. IMPACT RATED FRENCH STONE SURROUND & 6" E.E. 'MIN. MASONRY EDGE STEEL INSULATED IMPACT VULKEM SEALANT ON DOOR INSTALL PER T PRODUCT APPROVAL RETURN OPTIONAL SEE ELEVATIONS) PROVIDE 2-1/4" MASONRY WINDOW UNIT DISTANCE WATERPROOFING INSIDE & FACE OF OPENINGS, SEE SPECS. RATED OVERHEAD DOOR wl BACK SIDE & FRONT OF BUCK EDGE DISTANCE IMPACT RATED SLIDING WOOD VENEER INSTALL PER FOLDED OR NOTE: DOOR INSTALL PER PRODUCT APPROVAL NOTE: VULKEM SEALANT ON BACK SIDE & FRONT IMPACT RATED FRENCH SOLDERED SILL lxBUCKS MAYBE USED IN LIEU OF2x BUCKS PRODUCTAPPROVAL WD. MOULD OVER lx BUCKS MAY BE USED IN LIEU OF 2x BUCKS OF BUCK DOOR INSTALL PER IIIIIIIIIIIIII1111M FLASHING SILL (SLOPED TOP) USE P.T. lx4'S W/ 1Y2" COIL NAILS @ 8" O/C, THE WINDOW/DOOR IS THEN TAPCONNED THRU THE lX6 SMOOTH USE P.T. lx4'S W/ 1Y2" COIL NAILS @ 8" O/C, THE WINDOW/DOOR PRODUCT APPROVAL JAMB CASING/ TRIM CEDAR BID. OVER IS THEN TAPCONNED THRU THE OVERHANGS APRON 1 BUCK TO THE CONCRETE STRUCTURE PER ITS Y4"=V-0" 1X PT. FURRING 1Y2"=V-0" *CAULK AS REQUIRED BUCK TO THE CONCRETE STRUCTURE PER ITS 11Y2"=V-0" 'CAULK AS REQUIRED ly2"=l'4- RESPECTIVE NOA REQUIREMENT. RESPECTIVE NOA REQUIREMENT. WONDOW MM71ERPROOF[He SLODUM OLMS DOOR Hfg�&D DnTAOL Q aanh%(RIE [DOOR NEZU DEVIML L Ir-fPOCAL WHOOM HEAD DE76ML Q TYPOC&L FREENCH DOOR MEAD DETaDL I c 2X6 P.T. BUCK W/ 1/4" DIA. x 2X4 P.T. BUCK W/ 1/4" DIA. x ACCEPTABLE WATERPROOFING 1-3/4" EMBED, @ 12" O�C., 6" E.E. INDICATES SKIM COAT PLASTER W/ SMOOTH FINISH CASING BY INTERIOR 1-3/4" EMBED. @ 12" O.C., 6" E.E. 1 . THOROSEAL MIXED w/ ACRYL 60 WATERPROOFING MEMBRANE AROUND CASING BY INTERIOR OR OWNER PROVIDE 2�1/4" MASONRY EDGE DISTANCE 2X6 P.T. BUCK W/ Y4" TAPCONS W/ WASHERS IY4" OR OWNER PROVIDE 2-1/4" MASONRY EDGE DISTANCE CASING BY INTERIOR OR OWNER 2X P.T. BUCK W1 1/4" DIA. x PERIMETER OF ALL WINDOW OPENINGS. EXTEND 9" MIN. AROUND PERIMETER FACE EMBED @ 8" O.C. MAX, 2" FROM CORNER lX6 P.T. NAILER 1-3/4" EMBED. @ 12" O.C., 6" E.E_ 1X6 P.T. NAILER JAMB EXTENSION AS NEEDED DRYWALL SEE JAMB EXTENSION AS NEEDED lX6 P.T. NAILER PROVIDE 2-1/4" MASONRY EDGE DISTANCE 2. VULKEM 35ONF R MEMBRANE, 25 WET MILS MINIMUM INSIDE OPENING & 10 WET MILS W/ AGGREGATE FOR STUCCO FINISH. EXTEND 12" MINIMUM AROUND DRYWALL SEE IMPACT RATED SLIDING RECESS IN CONCRETE WALL SECTIONS7 INTERIOR SILL, SEE BY INTERIOR DRYWALL SEE PERIMETER FACE. WALL SECTIONS1 DOOR INSTALL PER OR OWNER WALL SECT ION JAMB EXTENSION AS c . PRODUCT APPROVAL STEEL INSULATED IMPACT RATED IMPACT RATED WINDOW V NEEDED 4mon VULKEM SEALANT ON OVERHEAD DOOR wl WOOD VENEER INSTALL PER PRODUCT APPROVAL INSTALL PER PRODUCT APPROVAL IMPACT RATED FRENCH DOOR INSTALL PER PRODUCT BACK SIDE & FRONT APPROVAL OFB'CK EXI -END WD. MOULD OVER lX6 SMOOTH CEDAR VULKEM SEALANT ON WATERPROOFING BACK SIDE & FRONT EXTEND VULKEM SEALANT ON 0 EXTEND YlVA'T'ERPRO0FING, BID. OVER 1X PT. FURRING OFBUCK YVATER�P�RQOFI G BACK SIDE & FRONT OFIBUCK STONE OR BRICK EXTERIOR STONE SILL THRESHOLD 164 r� u WATERPROOFING INSIDE & —WATERPROOFING MEMBRANE AROUND /STUCCO STONE SURROUND & STONE OR BRICK �lt 7 7., 1,1 7 FACE OF OPENINGS, SEE OPENINGS, SEE SPECS. RETURN OPTIONAL THRESHOLD W, W4 SPECS. wl (SEE ELEVATIONS) STONE SURROUND & STUCCO W/ STONE SURROUND & SMOOTH FINISH WATERPROOFING INSIDE & STUCCO w/ RETURN OPTIONAL SMOOTH FINISH RETURN OPTIONAL STUCCO W/ FACE OF OPENINGS, SEE SMOOTH FINISH (SEE ELEVATIONS) > (SEE ELEVATIONS) SMOOTH FINISH CORNER BEAD FILLED CELL OR SPECS. *rl FILLED CELL OR POURED COL., SEE FILLED CELL OR WATERPROOFING INSIDE & POURED COL., SEE NOTE: FILLED CELL OR STONESURROUND STRUCT. NOTE: POURED COL., SEE FACE OF OPENINGS, SEE STRUCT. Ix BUCKS MAY BE USED IN LIEU OF 2x BUCKS POURED COL. AT IF APPLICABLE, SEE ELEVATIONS Ix BUCKS MAY BE USED IN LIEU OF 2x BUCKS STRUCT. SPECS. USE P.T. lx4'S W/ 1Y2" COIL NAILS @ 8" O/C, THE WINDOW/DOOR IS THEN TAPCONNED THRU THE CMU WALL, SEE STRUCT. USE P.T. lx4'S W/ V/2" COIL NAILS @ 8" O/C, THE WINDOW/DOOR IS THEN TAPCONNED THRU THE *CAULK AS REQUIRED BUCK TO THE CONCRETE STRUCTURE PER ITS ly2"=V-0" *CAULK AS REQUIRED IY2"=V-0" *CAULK AS REQUIRED BUCK TO THE CONCRETE STRUCTURE PER ITS 1Y2"=V-0" *CAULK AS REQUIRED ly2'.=l'-O'. RESPECTIVE NOA REQUIREMENT. RESPECTIVE NOA REQUIREMENT. Y&MRPROOM(a SPECS Fir SHOM QLA83 DOOR JAMB MAL [P O&RAW DOOR J&HB 13FTAL TYPOCA4 L MHOOM JAMB DEETUL FIFTYPOC&L FREHCH DOOR J&NB 0E7L%dL 1. ALL WINDOWS & EXTERIOR DOORS SHALL BE DESIGNED & INSTALLED TO WITHSTAND STONE OR STUCCO 4 ON PS, iiia APPLICABLE WIND LOADS AS REQUIRED BY FLORIDA BUILDING CODE 2017 AND ANY EXTENSION IAMB ---\ i OTHER APPLICABLE CODES. SLIDING GLASS IF APPI-ICABLE 2. GENERAL CONTRACTOR TO VERIFY MASONRY OPENINGS REQUIRED WITH WINDOW & ALUMINUM BI-PARTING DOOR SILL RISER (SEE MFG. SPEC's) MOULD & lX6 SMOOTH CEDAR BID. T LE OR EPDXY FLOOR (SEE EI-EV'S) IMHACT RATE D FRENCH DOOR INSTALL PER DOORJAMB EXTENSION Job No. 1802011 DOOR SPECIFICATIONS. SLIDING GLASS DOOR (VERIFY w/ OWNER) VULKEM SEALANT ON PRODUCT APPROVAL (SEE DOOR SCHEDULE) *ADJUST FINISH FLOOR AS F-- BACK SIDE & FRONT STONE OR STUCCO FRENCH DOOR & 3. ALL EXTERIOR WINDOW & DOOR GLAZING TO BE TINTED TO REDUCE SOLAR HEAT NECESSARY TO FINISH OUT FLUSH CASTSTONE OFBUCK 2X4 P.T. BUCK W/ 1/4" DIA. EXTENSION JAMB IF ALUM. THRESHOLD, GAIN IF REQUIRED BY ENERGY CALCULATIONS. ATTACHMENT PER wl SLIDING GLASS DOOR SILL SURROUND, BEYOND x 1-3/4" EMBED. @ 12" O�C., APPLICABLE (SEE ELEV'S) INSTALL PER � 1* S MFG. SPEC's RISER WINDOW SILL 6" E.E. PRODUCT APPROVAL 4. ALL WINDOWS& EXTERIOR DOORS TO HAVE A SOLAR HEAT GAIN COEFFICIENT (SHGC) EXTERIOR LANAI STUCCO RETRUN (SEE ELEVS) PROVIDE 2-1/4" MASONRY 1 X P.T. BUCK W/ Y4" AS INDICATED IN THE ENERGY CALCULATIONS. FLOOR FINISH EDGE DISTANCE TAPCONS lY2"EMBED 5. G.C. SHALL SUBMIT ALL REQUIRED ENGINEERED SHOP DRAWINGS AND DOCUMENTED CONCRETE F LOOR SLAB SLOPE DRIVEWAY PAVERS (VERIFY W/ WATERPROOFING INSIDE & SILL & APRON BY INTERIOR VULKEM TRAFFIC COATING @ 12" D.C., 2"MAX WINDOW AND DOOR TESTING SHALL BE SUBMITTED FOR REVIEW AND APPROVAL BY THE OWNER) SL PEtZ FACE OF OPENINGS, SEE 0 OR OWNER FROM CORNERS. ARCHITECT. SPECS. tu la� j- STONE OR BRICK 6. SEE FLOOR PLANS FOR WINDOW & DOOR LOCATIONS- w lX6 P.T. NAILER PAVERS, RISERS & THRESHOLD (TYP.) FINISHED FLOOR, BY OWNER FL-MR105' FaM-.4A00 7. ALL WINDOWS & DOORS SHALL BE MANUFACTURED TO PROVIDE ALL JOINING DRYWALL SEE WALL l/n MATERIALS AND NECESSARY INSTALLATION ACCESSORIES AS REQUIRED PER WINDOW OR DOOR DESIGN TO MEET CODE FOR LOADS. INDICATES CONCRETE SLAB (SEE STRUCTURAL DWG's) I STUCCO W/ SMOOTH FINISH SECTIONS uj N4"RECESS CONCRETE SLAB TYP. Lu z 8. SEE BUILDING ELEVATIONS, DOOR & WINDOW SCHEDULES FOR HEAD HEIGHTS, POURED CONCRETE SILL (SEE STRUCTURAL DWG'S) (0 5 0- V RECESS @ DOOR MUNTIN BARS, AND OVERALL CONFIGURATION. INDICATES STEEL INSULATED DOOR w/ WOOD VENEER AlY2. 4Y�t" THRESHOLD (SEE DOOR SCHEDULE) NOTE: 9. SHOWER WINDOWS TO HAVE WINDOW TREATMENT FOR PRIVACY. CONCRETE FLOOR lx BUCKS MAY BE USED IN LIEU OF 2x BUCKS SLAB USE P.T. lx4'S w/ %" COIL NAILS @ 8" O/C, THE WINDOW/DOOR IS THEN TAPCONNED THRU THE *CAULK AS REQUIRED *CAULK AS REQUIRED 1Y2"=V-0" *CAULK AS REQUIRED BUCK TO THE CONCRETE STRUCTURE PER ITS 1Y2"=V-1)" *CAULK AS REQUIRED lY2"=l'-0-' 901 G&RME [DOOR OLL DET&L V[PDCAL NqJHDCW RESPECTIVE NOA REQUIREMENT. BELL DE71EL 7YNCAL FREMCH [DOOR SADDLE DE7adL [UTEMOR WMOMW A DOOR (WHERAL H07ES SUMHO (MaS8 [DOOR OLL DIET&L IN) is FLA �l 00 REWSIONS BY DATE qt- Apermit sets GS 10.4.2018 GUY GRAY SPACE SAVER V41TH 4" DEEP BOX FOR METAL STUD WALL WATER HAMMER ARREST( HW&CWHOSECONNEC WNACUUM BREAKERS (WATTS OR EQUAL) 2017 FLORIDA BUILDING CODE -RESIDENTIAL 1/2" HW & PER FBC 2017 P405.3.1: CWPIPING "A WATER CLOSET, URINAL, LAVATORY OR BIDETSHALL NOTBE 2" DIA. WASTE FINISHED WALI SET CLOSER THAN 15 INCHES FROM ITS CENTER TO ANY SIDE OOR WALL, PARTITION, VANITY OR OTHER OBSTRUCTION, OR CLOSER FINISHED FL iL�= -TO- CENTER BETWEEN ADJACENT THAN 30 INCHES CENTER FIXTURES. THERE SHALL BE NOTLESS THANA 21-INCH CLEARANCE INFRONT OF THE WATER CLOSET, URINAL, LAVATORY OR BIDET TO ANY WALL, FIXTURE OR DOOR. 3/8"=1'0" TYMCAL [PLUMMMU PK7URE CLEARANCE IF) IWASHm MACHME CONNECMON BE7ML J BEAD VERTICAL WALL PAN FLASHING NAILED TO WALL WITH 300, 1 RETURN. ROOF ABUTTWO CMU WALL Z' z C.M.U. WALL - REFER TO DRAWINGS FOR DETAILS. 5/8" STUCCO EXTEND ELASTOFLEX SAP UP WALL BEHIND COUNTER -FLASHING MIN. 4". 4 48" max EXTERMH DROPPED COLONG DEML 1. WATER HEATER: SEE MANUFACTURER'S SPECS FOR INSTALLATION DETAILS. 2. THERMAL EXPANSION PROVISIONS REQUIRED BY USE OF THERMAL EXPANSION TANK OR APPROVED. DEVICE. 3. COORDINATE WITH PLUMBING PLANS HOT WATER!,_� COLD WATER SUPPLY SUPPLY WATTS BRVT PRESSURE RELIEF VALVE HEAT PRESSURE TRAPS RELIEF DRAIN HOT WATER WITH 2" AIR GAP RETURN (if recirc) CHECK T&P TO GROUD VALVE WITH 211 Al A H T GRO AIR V LV RELIEF AL Uj 2 U) 5 Lu < m 1� IT, 'r " �SOUND INSULATION IF REQUIRED I (VERIFY w/ OWNER) 7 5/8" DRYWALL EA. SIDE **SEE NOTE" PROVIDE LEVEL 5 FINISH ON ALL EXPOSED INTERIOR PAINTED DRYWALL SURFACES METAL FRAMING (25ga) @ 16" O.C. MAX. SOUND INSULATION, IF REQUIRED (VERIFY W/ OWNER) METAL SILL CHANNEL OVER PLATE NOTE: **USE WATER RESISTENT GREEN BID FOR ALL PAINTED NON TILED WALLS NOT IN 2"AIR GAP NOT TO SCALE 112 20 ga. METAL FRAMING @ 16" O.C. MAX. OR AMRSTRONG DRYWALL GRID SYS TEM (SUSPENDED FROM STRUCTURE 4'0.C. MAX.) PROVIDE TEST TEE WITH SCREWED COUNTER- COLUMN OR PARTMON CD C:D _ SUNK ABS PLASTIC PLUG: Z AS SHOWN ON FLOOR PLAN TAPEkED-THREAD WTH CLEANOUT FACE SHALL TFE JOINT COMPOUND BE WITHIN 4" OF WALL SURFACE PROVIDE WHERE CLEANOUT TEE PIPE EXTENSION IF REQUIRED IS CONCEALED IN A CHASE OR PARTITION, PROVIDE A ROUND 18 GAUGE STAINLESS STEEL COVER WITH BEVELED EDGES AND FLATHEAD MACHINE SCREW T CONCRETE FLOOR SLAB NOTE: PROVIDE WOO WHERE SHOWN ON PLAN AND ON S, NITARY WASTE BRANCHES NOT SERVED WITH A FLOOR CLEANOUT. LOCATE ABOVE FIXTURE FLOOD RIM WITHIN 4'OF FLOOR. CONSULT LOCAL CODES FOR OTHER WCO REQUIREMENTS. 1 1/2"=T-0" 14 WALL CLEAN OU7 DEML 8" NOT TO SCALE CMM DE7ML CMU OR CAST IN 4 4 PLACE WALL- P.T. 2X4 X 8" LONG w/ CONCRETE (2) Y4" x 3" TAPCONS q4 16 < TO CONCRETE q FASTENERES AS REQUIRED------� P.T. 2X4 STRONG BACK BRACE @ 48" O/C MAX rP.T. 2X4 STRONGBACK P.T. 2x4 @PERIM w/ 4 @ 48" O/C MAX )/4" x 1 Y4" EMBED TAPCONS @ 16" O/C 4 CLIP ANGLE, NO LESS THAN METAL 17 CLIP q JOIST DEPTH MINUS 1/2" (ATTACH CLIP P.T. 2x4'S @ 24" O/C lx T&G CLG NAILED TO 2X4'S & TRACK TO CONCRETE W/ EXP., 4 ANCHOR BOLTS, OR TAPCONS) NOTE: 1-1/2" V-0" PROVIDE SOLID BLOCKING & BRIDGING AS REQUIRED 110 CMMa JOM7 ATTACHEMEwr 0FTML . , DIRECT CONTACT W/ WATER SUCH AS BATHROOMS & KITCHENS, OR CEMENT BACKER BID. (DUROCK) FOR ALL TILED WALLS IN DIRECT CONTACT w/ WATER, SUCH AS SHOWERS & TUB SURROUNDS" NOT TO SCALE 1 1/2"=l'-O" 8 TYMCAL INTEMOR [PAR-flTOK WALL �NON-BEAMNQ� _4 5/8" STUCCO FINISH (VERIFY FINISH & COLOR) 7 0 UJ F_ 0 Z LU :� EXTERIOR LL CL LLI w (D SIDE LU m 0 5/8" GYP. BD. FASTENED 6" 0,C.@ PERIMETER & 8" O.C. BALANCE NOTE: **USE WATER RESISTENT GREEN BD. FOR ALL PAINTED, NON -TILED WALLS NOT IN DIRECT CONTACT w/ WATER SUCH AS BATHROOMS & KITCHENS, USE CEMENT BACKER BD. (DUROCK) FOR ALL TILED WALLS IN DIRECT CONTACT w/ WATER, SUCH AS SHOWERS & TUB SURROUNDS" 1 1/2"=V-0" 1 1/2"=V-0" _T 7 TYMCAL 9K7EMOR CMU WALL 0. N: 1 t. N -d METAL JOIST TRACK INTERIOR (UNFINISHED) METAL JOIST CMU WALL OR CAST IN INTERIOR PLACE CONCRETE (SEE STRUCTURAL SPACE DWG's) (FINISHED) 5/8" DRYWALL ON MIN. 7/8" FURRING CHANNELS @ 16" O.C. MAX NOTE: **USE WATER RESISTENT GREEN BD. FOR ALL PAINTED, NON -TILED WALLS NOT IN DIRECT CONTACT w/ WATER SUCH AS BATHROOMS & KITCHENS, OR CEMENT BACKER BD. (DUROCK) FOR ALL TILED WALLS IN DIRECT CONTACT w/ WATER, SUCH AS 1 1/2"=T-0" SHOWERS & TUB SURROUNDS' 1 1/2"= 1 -0 (5 7YRCAL mnimam CNU WALL VENT W1 �_�ROOF PERFORATED CAP TRUSSES @ 24" OlC_____m I EXTERIOR FINISH C.O. PLUG 3" ABOVE TOP 0 z 0 Lu (SEE ELEVATIONS) (SCREWED) OF PRIMARY W 3- DRAIN PAN AHU 0 < TEE IN Uj LU PREFAB ATTIC ACCESS ------------- :4 > SCUTTLE FRAME ATTACH UNION PER MANUF. SPEC'S z ........... _0 CONNECTIO EL13OW TSP T, 0 LU m 2 0 U) TSP -1" . . . . . . N,) A. SLOPE DRAIN LINE TO CONDENSATE --FPRE-MANUF RECEPTOR (MIN. 1/8" PER FOOT) GYP. BD. FINISH B. DRAIN LINE SHALL BE COPPER SCUTTLE DOOR OR (SEE WALL TYPE & TYPE 1" AND INSULATED. 5/8" GYP BOARD SCREWED TO FLOOR PLANS) C TSP - FAN TOTAL STATIC PRESSURE. MIN 1/2" CDX PLYWOOD PANEL DECORATIVE TRIM IS PART OF SCUTTLE FRAME �CEILING lU WALL OR CAST IN PLACE )NCRETE -E STRUCTURAL DWG'S) %LL INSULATION 7-E TYPICAL WALL SECTIONS) JRRING & GYPSUM BOARD :R TYPICAL WALL SECTIONS - 3" GYP. BD. FINISH EE WALL TYPE & FLOOR PLANS) ETAL STUD FRAMING EE WALL TYPE & FLOOR PLANS) )UND INSULATION (ziEE WALL TYPE & FLOOR PLANS) NOT TO SCALE NOT TO SCALE 9 7VIMCALATM ACCESS DEML 5 STUD WALL 70 CWHCRETIE WALL DEML 6!� 01 �111 On 0 u r 94 z now - Job No 1802011 FL 0OW05 FIRM-AAOO TYPICAL DETAILS A902 HDIENSME P-71RAIP DEMML 1 1/2"=V-0" I 7- EXTERIOR LIGHTING FIXTURE SCHEDULE QUANT I MOUNTING D FLR h FLR 12 FLR TOTAL SYMBOL FIXTURE NAME I BULB WATT & TYPE MOUNTING HEIGHT Ll H36LVTAT-301 1 -TBZBB (BRONZE) 5w AMBER LED MR16 CEILING IN CEILING H36LVTAT-301 1-SNBB (NICKEL) 9 L2 SeaGull 8313901EN-10 WALL SCONCE 9w AMBER LED Al 9 WALL 6'�6' 3 4 7 L3 SAGA STEP LIGHT (HORIZ LOUVER) (4) lw AMBER LED PER FIXTURE WALL 12" I SG-R-ILED-HDL-AML 2 2 L4 L5 brayden 1070 WALL MOUNT (1) lOw LED WALL 8'-6" 4 4 L6 HINKLEY 1665TT LED (1) 8w LED CEILING @ CEILING CLG FLUSH MOUNT 1 1 L7 I L8 PENTAIR INTELLIBRITE 5G INTELLIBRITE LED 26W -TURTLE CEILING BELOWWATER 3 3 I EDITION LINE GF -7 MB Ll Li =-Ll Li ROOM TO POOL LIGHTS '@ +60'(VERIFY HT.) " w ZKIZ B FOR TV MOUNT ELEvAT071 R vpff, Ll -0 1ST FLOOR ELECTRIC PLAN SCALE: 3118" = V-0" L8 m L8 mv NOTE: PER 62B-33.0155(l)(n) ALL WINDOWS AND GLASS DOORS VISIBLE FROM ANY POINT ON THE BEACH MUST BE TINTED TO A TRANSMITTANCE VALUE (LIGHT TRANSMISSION FROM INSIDE TO OUTSIDE) OF 45% OR LESS THROUGH THE USE OF TINTED GLASS OR WINDOW FILM VERIFY FIXTURE FINISHES WITH OWNERIINTERIOR DESIGNER VERIFY FIXTURES WITH DEP SUBMITTAL ELECTRICAL LEGEND ELECTRIC METER WALL MOUNTED FIXTURE PHONEJACK DOUBLE CAT 5e CABLE f:;jA ELECTRIC PANEL FRI DISCONNECT 4— CEILING MOUNTED FIXTURE VIDEO OUTLET S CENTRAL VAC. HOSE OUTLET 220 VOLT RECEPTACLE WALL MOUNTED J-BOX Q EXHAUST FAN SINGLE OUTLET 0 SMOKE DETECTOR 3@r DUPLEX OUTLET CEILING MOUNTED J-SOX (D THERMOSTAT nCl� DUPLEX OUTLET - HALF SWITCHED GF G.F.C.I. PROTECTED OUTLET L -41`6�-- PULL CORD FIXTURE �t SPRINKLER TIMER 0 INTERCOM WPGF WEATHER PROOF GFCI OUTLET DUPLEX FLOOR OUTLET RECESSED ADJUSTABLE FIXTURE KEYPAD WALL SWITCH 13 RECESSED LIGHT FIXTURE MOTION DETECTOR -bl�-3 3-WAY WALL SWITCH VP13 VAPOR PROOF RECESSED FIXTURE -61�4 4-WAY WALL SWITCH FLOURESCENT LIGHT FDCrURE -v)-D DIMMER WALL SWITCH CEILING FAN -bl�-PB PUSH BUTTON SWITCH A f\ FLOOD/SECURITY LIGHTS UNDER CABINET FIXTURE WALLLOUVER t00 CFM FAN CONTROILED BY GARAGE CO SENSOR —MOUNT VAC & RECEPTACLE TOCOLUMN, HARDWIRE w/ SWITCH LL---- POO EQUIP GARAGE LEVEL ELECTRIC PLAN SCALE: 3/16" = V-0" REVISIONS BY DATE., penit wt-s __ GS 10.4.2018 lStBlildilgCom�t, GS 3,12,2019 cm cvi tv *u L-2 $.4 0 4-; r u slow , Aw"m z 1� 3ob No. 1802011 E201 I I PYTPRIOR I 1QHT1Nr3 FIXTLIRF SCHEDULE IMBOL I FIXTURE NAME QUANTITY BULB WATT & TYPE MOUNTING MOUNTIN(' HEIGHT L--j 3 FLR I FLR 12 FLR TOTAL I Ll H16LVTAT-101 I-TBZBB (BRONZE) H36LVTAT-301 1 -SNBB (NICKEL) 9 - 9 Sw AMBER LED MR16 CEILING IN CEILING Lj I SeaGull 8313901 EN-1 0 WALL SCONCE 3 4 - 7 gwAMBERLEDA19 WALL 6'-6" Lj I SAGA STEP LIGHT (HORIZ LOUVER) SG-R-lLED-HDL-AML 2 - - 2 (4) lw AMBER LED PER FIXTURE WALL 12" Lf I L5 brayden 1070 WALL MOUNT 4 - 4 (1) low LED WALL 8'4' L6 HINKLEY 1665TT LED CLG FLUSH MOUNT 1 1 (1) 8w LED CEILING @ CEILING L" __�ELOW US PENTAIR INTELLIBRITE 5G - 3 3 INTELLIBRITE LED 26W -TURTLE EDITION CEILING WATER LINE NOTE: PER 62B-33.0155(i)(n) ALL WINDOWS AND GLASS DOORS VISIBLE FROM ANY POINT ON THE BEACH MUST BE TINTED TO A TRANSMITTANCE VALUE (LIGHT TRANSMISSION FROM INSIDE TO OUTSIDE) OF 45% OR LESS THROUGH THE USE OF TINTED GLASS OR WINDOW FILM VERIFY FIXTURE FINISHES WITH OWNERIINTERIOR DESIGNER VERIFY FIXTURES WITH DEP SUBMITTAL Fr - - 17 IL I � LL -m-M (M ELECTRICAL LEGEND PHONEJACK [a ELECTRIC METER WALL MOUNTED FIXTURE DOUBLE CAT 5e CABLE [:�N ELECTRIC PANEL VIDEO OUTLET FRI DISCONNECT 4— CEILING MOUNTED FIXTURE S CENTRAL VAG. HOSE OUTLET 220 VOLT RECEPTACLE # WALL MOUNTED J-BOX EXHAUST FAN SINGLE OUTLET SMOKE DETECTOR 3@1: DUPLEX OUTLET —0— CEILING MOUNTED J-BOX THERMOSTAT 4;� DUPLEX OUTLET - HALF SWITCHED IL SPRINKLERTIMER GIF G.F.C.I. PROTECTED OUTLET -4PC\_ PULL CORD FIXTURE (D INTERCOM WPGF WEATHER PROOF GFCI OUTLET KEYPAD 151 DUPLEX FLOOR OUTLET RECESSED ADJUSTABLE FWTURE -69- WALL SWITCH 13 RECESSED LIGHT FIXTURE MOTION DETECTOR -b+3 3-WAY WALL SWITCH VP13 VAPOR PROOF RECESSED FIXTURE -b9-4 4-WAY WALL SWITCH FLOURESCENT LIGHT FIXTURE CEILING FAN -b,�-D DIMMER WALL SWITCH -br)- P B PUSH BUTTON SWITCH A /\ FLOODISECURITY LIGHTS UNDER CABINET FIXTURE @ +60"w/ BACKING FORTVIVIOUNT -7 F_ VP Q qutv :aj 0 @ +60"w/ BACKING FOR TV MOUN BFIDR( )01%14 VPU +60"w/ BACKING FOR TV MOUNT7 J, 2ND FLOOR ELECTRIC PLAN SCALE: 3/16" = V-0" Q RMSIONS BY DATE permit sets GS 10.4.2018 ISt Building Comments GS 3.12.2019 Cq 0 U �_l t4 4_� 'T 4-) U Ammon" vam Job No. 1802011 t FL-0011105 FIRWAA00337 p , _[ 't I� GARM]'NE LEVEL MOP? CICHEDULE %3 Sl ZE MARK 1 ! WD HC�'11` TYPE NOTES 1 3,-0" 8,-lo" FRENCH 2 16'-0" 8'- �)" OVERHEAD GAMGE DRI 3 2'-6" 8:'--), FRENCH 4 S-O" 7".- �"I'l EXT SWING PVC JAME 5 S-O" 7'--!�i` EXT SWING PVC JAME 6 2'-6- 8"-- 1 ),:1 FRENCH -- 7 2'-8" 6-:1'' INT SWING (SC) MIN -1 3/8" T , HK, SLLF CLOSER 8 2'-6", 8'- )1` INT SWING (SC) 9 5'-0' 81 1 INT SWING DEIL (SC) 10 2'-8" 8' �l INT SWING Sc 11 2'-8" 81- C INT SWING 0� 12 '2'-8" 6-j" INT SWING (SC) MIN 1-3/8" THK, SEV CLOSER 13 2'-8" 8'---l)4' INT SWING (S MIN 1 S160 Tw, sELF CLOSER' 14 2'-8" 8'- 1:1' INT SWING Sc 15 2'-8" 8'-:1" INT SWING SIC 16 2'-43' INT SWING GARAGE LEVEL WINDMil' SCIIEDULE SIZE ...... HEAD HT MARK WD HGT TYPE NOTES ELEV 1 2'-0" 8:-0: SIDELIGHT 9-0 1 2 2'-0" 8-0 SIDELIGHl' 91-01, 3 2'-8" 5'-6" CSMNT 8'-0" 4 2'-8- 5-6.. CWNT 81-01, 5 2' 8" 5'-6" CSMNT 8'-0' 6 5'--0' 5'-6- CSMNT DOIJI:H-j: 8,-0" 7 4'-0'3 5'-0" FIXED DOLOU 8,-0" U002 cl) �ql Ron, z Kj 0 ON 112 1611-10" Dyl 1 112 0. GARAGE 10,40" clg 49'1 x 38'1 210 5�' CHEW 4-1 )10 4`1 TI STC)TtA.I CHASE 011 '9 4 C ABV EAEVATOR 12'-F.l"x 11 -2" -IRAGE ROOM CIg I A I �11 2D 17 SIT Irgo low— 14 WA "a on OD4 fE-- C I q PUM 2'-0' le - va cy cIq ABLE AREA BELOW ELEVATED DECK IUIP. TO BE ELEVATED ON "DIESTALSISTANDS ABOVE DIFE (DESIGN FLOOD ELE`o'IA TION) OF NAVID 16.4 15'-9" -23'1 18'-6" 4'-0" 20'1 . ...... 7XI I 1 POOL ABOVE ...... L LL 1 1 �/ING AREA CALCULATiDN 11) 1 - "I FLOOR LIVING 2.15811 SF 2) 21,,T) FLOOR LIVING V263 SF 3) I-C"16BY 338 F . ..... �-1 82 SF DETAIL AREA CALCULAI ON 1) Tv:TFLOOR LIVING 25,81 SF 2) 21IIID FLOOR LIVING 1263 SF 3) 1.13113BY :328 SF BALCONY 1 0 55 SF BAU�NDNY 2 200 SF BON II ROOM 747 SF COVERED ENTRY 1132 SF GARAGE 1 11:577 SF OUTDC)OR LIVING 359 SF 7!(,7�3 =SF 200 SERIES KEYNO-FE-S 200 - MIRROR 201 - BUILT-IN CABINETRY 202 - OPEN SHELVES 203 - CUSTOM CLOSET INTERIOR 204 - TEMPERED GLASS SHOWER ENCLC LIRE 205 - CURB FOR SHOWER 206 - TROUGH FOR POOL INFINITY EDGE 207 - DRAPERY POCKET 208-.. 209 - ADJACENT WALLS TO HAVE MIN R�'l I I NSUL & MIN 1/2"GYP BD ON GARAGE SIDE FOR GARAGE SEPARATION - MIN 6/8" TYPEX'GYP BID FOR GARAf"E 210 CLG BELOW HABITABLE ROOMS 211 - T.S. COLUMN IN WALL 212 - T.S. COLUMN IN DECORATIVE COL/I 213 42" HIGH CMU WALL 214 &1 ENGINEERED SMART FLOOD I?1-.-,NT PROVIDING 200 SF OF FLOOD COVF.:I;AGE 215- 216- 217- 218- 219- 220- NOTE: DESIGN FLOOD ELEVATION IS AT 16.4 NAVD. PER FBC R322.1.8 BUILDING MATERIALS AND INSTALLATION METHOU�:', USED FOR FLOORING & INTERIOR AND EX*T ERIOR WALLS AND WALL COVERINGS BELOW THE DESIGN 1: LCOD ELEVATION (DFE) SHALL BE FLOOD DAMAGE RESISTNNT MAI THAT CONFORM TO THE PROVISIONS 01: FEMA TB-2. MECHANICAL, ELECTRICAL, & PLUMBING SYSTEMS BFILOW DFE ARE T03E DESIGNED & INSTALLED TO PREVENT WA TER FROM ENTERING OR ACCUMULATING WITHIN THE COMPON FI,IITS AND TO RESIST HYDROSTATIC AND HYDRODYNAMIC LOADS AND STRESSES PER FBC R322.1.6 ELOOD VEWT CALCULATION 81 ENGINEERED FLOOD VENTS THAT PROVIDE 200 SF OF FLOOD COVERAGE 7 GARAGE: 1877 SF/200 111 9.3 = 10 VENTS LOBBY & STORAGE AREAS 1085 SF/200 = 6.4 6 VIEWS BELOW PCOL DECK AREA 1058 SF/200 = 5.3 6 VENT!, 'N OF THE FLOOD VENT OPENINGS WILL THE DE.SIG PROVIDE': FOR EQUALIZATION OF HYDROSTATIC FL FORCES ON EXTERIOR WALLS BY ALLOWING FOR TI-:E AUTOMPI I'IC ENTRY AND EXIT OF FLOODWATERS AS SPECIFI 1: ID IN SECTION 2.7.2.2 OF ASCE 24. PER FBC , R322.2.2'FOOT NOTE 2.1 THE BOI TOM OF EACH OPENING SHALL BE NOT MORE THAN I FOOT ABOVE THE HIGHER OF THE FINAL INTEFi[OR =LOOR AND THE FINISHED EXTERIOR GRADE IMMED INITELY 3ELOWTHE OPENING I I —jkci JI� U4, C y- �9 C ple, AQ� GARAGF]:"� LEVEL PLAN SCALE: 1/4" V-011 W REVISIONS BY DATE T-- A permit sets GS 10.4.2018 0 a U. 0 U Q) 4-) .,.q u --1 �-q cd 0 4-j (z R um u 4-1 Iz < z z Mono 1-4 Mj-will I -.— Job No. 1811):.'1011 Fl, -0011105 FIR"k-l-AM0379 rlA2`10 JAN P, 6 2M Luele countv� hH, I ST IFLOOR DOOR 11.1��'CHEDULE sizi�i� MARK TYPE NOTEEl WD 1-1 1: 3T 102 15'-0" 1!� -0" SILD GLASS OXX POCKET S(;D 103 6'-0" '1 ��' -0- SILD GLASS 20'-0" 1 l�l' -0" SLO GLASS 6XX0 105 12'-0" 1 � " -0" SILD GLASS OXX 106 2'-6 1. ;1, on Pocket boor 107 2'-8 9�' -0* INT SWING (SC) 108 2'-6 a, 0" Pocket Door 109 2'-8" 8: 0" INT SWING 110 2'-8 a -on INT SWING SSCCI 111 2'-8 �0" INT SWING SC ISC 112 2'—B" .0" INT SWING 113 5-0 0" 'INT SWING -,bBL (SC) 114 2'-8" T S 'G SIC 115 2'-6 0 1NNT SW�NG Sc 116 2'-6 Ill - 0" INT SWING SIC 117 9,—,, ll:, 1) 11 INT 4M qr. 1 ST FL(��:o:DR WINDOW SCIFIEDULE SIZE HEAD HT MARK TYPE: NOTES WD HGT ELEV 101 4'-0" 1'-6" FIXED 4'-6" BETWEEN CAB'S ' VI jT. 102 4'-0" 1'-60 FIXED 4--6- BETWEEN CABI'lS, VERI`I IT, 103 2'-6" 5-0" CSMNT W—C 104 2'-0" 5-0" CSMNT 91-0. 105 2'-0" 5-0" FIXED 91-0. 106 2'-0" 5-0" CSMNT 9,-0" 107 5-4" 6'—Om CSMNT DEL 91-0. EGRESS, w/ FIXED GLASS BELOW 109 2'-0" 5-0" CSMNT 91-011 110 4'-0" 5-6" CSMNT DIK 91-0. 111 5'-4" 6'—Om CSMNT UK 91-01, lin " '. w fl PCIAIT in, n" FIVM P1 ACQ III 1ST FLOOR PLAN SCALE: 1/41' �-- V-0-1 FA '.31 AREA CALCULATIOP-1 �')OR LIVING 2581 :SF-1 OOR LIVING 1263:.3111� 338:::,,..F 4182 DETl AREA CALCULATION 1) IIST FL ()OR LIVING 2581 '::')F' 2) 2ND F1,11C)OR LIVING 1263::'F` 3) LOBBI( 338:31F BALCON'�( 1 55:::;F- BALCON'( 2 200::'>F' BONUS FlOOM 747::ZIF COVEREI.) ENTRY 62Sr.:, GARAGE IBM.,- OUTDOCIR LIVING 359 F 7483 S ) F- 200 SERIES KEYNOTEi:3) 00 - MIRROR Ill - BUILT-IN CABINETRY l')2 - OPEN SHELVES 03 - CUSTOM CLOSET INTERIOR (A - TEMPERED GLASS SHOWER ENCLOSLIRF-- 05 - CURB FOR SHOWER 06 - TROUGH FOR POOL INFINITY EDGE 0 7 - DRAPERY POCKET 08 09 - ADJACENT WALLS TO HAVE MIN R-1 1 Pll�13.11- & MIN 1/2"GYP BD ON GARAGE SIDE FOR GARAGE SEPARATION 1 13 - MIN 51811 TYPE 1XI GYP BD FOR GARAGE CLG BELOW HABITABLE ROOMS 11 - T.S. COLUMN IN WALL 12 - T.S. COLUMN IN DECORATIVE COLIFOI: I' '13 - 42" HIGH CMU WALL 14 - 8l ENGINEERED SMART FLOOD VENT PROVIDING 200 SF OF FLOOD COVERAIDL JIB '17- 119- 19- x,-Cj a<,s-;1Cp b4: 'cr 00 I REVISIONS Apermit sets CIA BY DA GS 10A Ile - ..q rp 0 rill 0 CID el 6l u Job No. 18D,201 1 � I I� )III, � I t � k,l -i FIR:vl -AA0033 00 REVISIONS BY DAT Apenit sets GS 104.21 2ND FLOOR �1)00R SCHEDUII.E SIZE MARK! TYPE NOTES WD HIST 261 8'-0- 8'-0- 1 SLD GLASS-_ 202- 8'-O� SLD GLASS _20S 8,-04 �INT SMNG 204 2'-6" 8 1 -0' INT SMNG c St - M5 2'-8� 8'4� TNT ­SMNG St, 1 206 2'-B' 8'--Y- (N-T S �NG 96 _207 -2r4* 8'_4�*T_SWING SC —96 - 2 W 8F-_O� _INT SWING Sc _109 - -1 �-6' 8�_-V_ INT SWING __ C S 210 2�4" 8-��_INT SWIN_Gt_S_Q, 211 2'-8" 8'-0' INT SWING SCI 212 2'-6" 8'1:e- - Pm—ket or 213 2'- 6" 8'-0" INT SWING 2PI111D FLOOR WIN11','11OW SCHEDULE HEAD HT MARK TYPE WD HGT ELEV 201 2'-6" 5'-0" CSMNT 203 2'-6" 3'--da CSMNT 204 2'-4" 3' _b. FIXED 205 2'-4" 13' -0. FIXED 206 2'-4' 13'�:O' FIXED __8_0 208 5'-()� 5:T CSMNT DBL 8'4�_ 209 2'-W 5�-00 CSmNT 81_0�___ 210 4'-04 54' FIXED 8'-0" 211 2'4� 5'-d* CSMNT 81-0 212 2'-00 :!�'-O" FIXED Er-cr 213 S-00 Y-0" HOR SLIDE NOTES EGRESS �200 SERIES KEYNOTE��� 200 - MIRROR 201 - BUILT-IN CABINETRY 202 - OPEN SHELVES 203 - CUSTOM CLOSET INTERIOR :104 - TEMPERED GLASS SHOWER ENCLOSU ��E. :205 - CURB FOR SHOWER 2116 - TROUGH FOR POOL INFINITY EDGE 20'r - DRAPERY POCKET 208 - .. 2109 - ADJACENT WALLS TO HAVE MIN R-1 1 INS IJL & MIN 1/2" GYP ED ON GARAGE SIDE FOR GARAGE SEPARATION 2 10 - MIN 518" TYPEXGYP BD FOR GARAGE CLG BELOW HABITABLE ROOMS 2 T I - T.S. COLUMN IN WALL 2 112 - T.S. COLUMN IN DECORATIVE COUPOS I' 2 13 - 42" HIGH CMU WALL 2 4 - 8"x16" ENGINEERED SMART FLOOD VENT PROVIDING 200 SF OF FLOOD COVERAGE 215- 216- 2 IT - 2 113 - 2 19 220 )icy- cc, cs AIVAC - &_ &ca�(] im v-0 010 A III p u U Q C) 0�1 U 4-,) Job No. 18,'."��01 1 Ilk! "kA003.3"1' A2 2