HomeMy WebLinkAboutNOA 1-25-19Lawson Industries, ]Inc.
8501 NW 90 Street
Medley, FL 33166
SCOPE:
This NOA is being issued under the app]
The documentation submitted has been
Section to be used in Miami Dade Coui
AHJ)-
This NOA shall not be valid after the e
Section (In Miami Dade County) and/or
have this product or material tested for q
the accepted manner, the manufacturer
revoke, modify, or suspend the use of suc
revoke this acceptance, if it is determinc
material fails to'meet the requiretuents of
This product is approved as described lic
including the High Velocity Hurricane Zc
DESCRIPTION: Series "3200" Outsw
SCANNhU
BY
X
MMM-DADE COUNTY
PRODUCT CONTROL SECTION
11805 SW 26 Street, Room 208
T(786)315-2590 F(786)315-2599
www.miamidade.gov/economy
ble rules and regulations governing the use of construction materials.
iewed and accepted by Miami -Dade County RER -Product Control
and other areas where allowed by the Authority Having Jurisdiction
iration date stated below. The Miami -Dade County Product Control
le AHJ (in areas other than Miami Dade County) reserve the right to
dity assurance purposes. If this product or material fails to perform in
ill incur the expense of such testing and the A14J may immediately
product or material within theirjurisdiction. RER reserves the right to
by Miami -Dade County Product Control Section that this product or
e applicable building code.
in, and has been designed to comply with the Florida Building Code,
APPROVAL DOCUMENT: Drawing Nol
Window", sheets I through 07 of 07, dated
1
11
signed and sealed by Thomas J. Sotos, P.1I
with the Notice of Acceptance number and I
AUSSILE hIPACT PLATING: Large an
Limitations:
1. See Design Pressure (DP) VS Window
2. See glass types in -sheet 5 & 6. The moi
require tempered glass, if used at 3 0 ft i
LABELING: Each unit shall bear a permai
following statement "Miami -Dade County I
RENEWAL of this NOA shall be considc
change in the applicable building code negal
TEW*IINATION of this NOA will occur 2
materials, use, and/or manufacture of 'the
product, for sales, advertising or any other
with any section of this NOA shall be cause
ADVERTISEMENT: The NOA number I
the expiration date may be dis layed in advcp
be done in its entirety.
Aluminum Casement Window — L.M.I.
L3200-0801 Rev D, titled "Series: 3200 Outswing Impact Casement
7/27/08 and last revised on NOV21, 2017, prepared by manufacturer,
bearing the Miami -Dade County Product Control Revision stamp
xpir tion date by the Miami -Dade County Product Control Section.
Small Missile Impact Resistant
INSPECTION: A copy of this entire NOA sl
and shall be available for inspection at the job ss
This NOA revises NOA No. 14-0908.20 and c(
as well as approval document mentioned above
The submitted documentation was reviewed by
F_4, L..L V L_ L f
ST. Lucie County, Permitting
RanAll E. St`offuc'
NOA Approval for
bFy: 4L dal
Is, configuration and glass types in sheets 5 and 6.
thic lite in insulated laminated glass is oriented at exterior side and
ve the grade
L label with the manufacturer's name. or logo, city, state, series, and0
luct Control Approved", unless otherwise noted herein.
after a renewal application has been filed and there has been no
ly affecting the performance of this product.
the expiration date or if there has been a revision or change in the
iuct or process. Misuse of this NOA as an endorsement of any
poses shall automatically terminate this NOA. Failure to comply
termination and removal of NOA.
eded by the words Miami -Dade County, Florida, and followed by
ing literature. If any portion of the NOA is displayed, then it shall
be provided to the user by the manufacturer or its distributors
at the request of the Building Official.
ists of this page I and evidence pages E-1, E-2 and E-3,
1. Chanda, P.E.
NOA No. 17-1212.22
Expiration Date: March 04,2019
P.A. Approval Date: Febru2ry 01, 2018
Page I
uavista Lot
I
4
Lawson Industries, Inc.
NOTICE OF ACCEPTANCE: EVIDENCE SUBMITTED
1. Evidence submitted in previous files
A. DRAWINGS
1. Manufacturer's die drawings and sections.
Submitted under NOA #08-1020.08)
2. Drawing No. L3200-0801, Sheets 1 through 07 of 07, titled "Series: 3200 Outswing
Impact Casement Window", dated 07/27/08, with revision "C" dated 08/25/14, prepared
by manufacturer, signed and sealed by Thomas 1. Sotos, P.E.
B. TESTS
1. Test report on: 1) Uniform Static Air Pressure Test, Loading per FBC TAS 202-94
2) Air Infiltration Test, per FBC, TAS 202-94
3) Water Resistance Test, per FBC. TAS 202-94
along with marked -up drawings and installation diagram of a ' series 3200 outswing
aluminum casement window, X configuration, w/5/16" ann. Lami glass w/PVB
laminate by DuPont, Test Report No.'s IE[ETI-08-2099A, liETI-08-2102A, RETI-08-
2097A HETI-08-2103A and FIEETI-08-2131A, all dated 07/10/08, signed and sealed by
Candido F. Font, P.E. (Submitted under NOA #08-1020.08)
2. Test reports on: 1) Large Nfissile Impact Test per FBC, TAS 201-94
2) Cyclic Wind Pressure Loading per F-BC, TAS 203-94
along with marked -up drawings and installation diagram of a series '0200 outswing
aluminum casement window, X configuration, w/5/16" ann. Lami glass w/PVB
laminate by DuPont, Test Report No.'s HETI-08-2099B, HETI-08-2100, HETI-08-
2101,BETI-08-2102B,HETI-08-2097B,HETI-08-2103B,HETI-08-2104, HETI-08-2105,
HETI-08-2106, BETI-08-2125, and HETI 08-2131B, all dated 07/10/08, signed and
sealed by Candido F. Font, P.E.
Submitted under NOA #08-1020.08)
C. CALCULATIONS
1. Anchor verification calculations and structural analysis, complying with FBC, prepared by
manufacturer, dated 10/01/08 and 01/30/09, signed -and sealed by Thomas J. Sotos, P.E.
Submitted underpreviousNOA #12-0127.21)
2- Glazing complies with ASTM E1300704/09.
D. QUALITY ASSURANCE
1. Nliami—Dade Department of Regulatory and Economic Resources (RER),
E. MATERIAL CERTMCATIONS
1. Notice of Acceptance No. 11-0624.02 issued to E.I. DuPont DeNemours & Co., Inc. for
their "DuPont SentryGlas@ Interlayer" dated 08/25/11, expiring on 01/14/17.
2. Notice of Acceptance No. 13-0129.27 issued to E.I. DuPont DeNemours &.Co., Inc. for
their "DuPont Butaciteg PVB Interlayer" dated 04/11/13, expiring on 12/11/16.
L 4 X"4A.—
Ishaq 1. Chanda, P.E.
Product Control Examiner
NOA No. 17-1212.22
Expiration Date: March 04,2019
Approval,Date: February 01, 2018
E-1
Lawson Industries, Inc.
E.
F.
MATERIAL CERTIFICA
3. Notice of Acceptance No.
their "Saflex Clear and C
STATEMENTS
1. Statement letter of conform ce to and complying with YBC 5t' Edition (2014), issued by
manufacturer, dated 09/02/147, signed and sealed by Thomas J. Sotos, P. E.
2. Department of State Certification of LAWSON INDUSTRIES, INC. as a for profit
zed under the laws of the State of Florida, dated 04/11/14
CONTINUED)
0423.17 issued to Eastman Chemical Company (MA) for
r Glass Interlayers" dated 06/19/14, expiring on 05/21/16.
3.
4.
complying with YBC-2010, dated 01/225/12, signed and
No. 12-0.127.21)
nterest, dated 10/01/08, signed and sealed by Thomas J.
Sotos, P. E.
Submitted tinder NOA No. 08-1,20.08)
5. Laboratory compliance letter for Test Reports No.'s HETI-08-2099A, dated
07/10/08, HETI-08-2102A, date 07/10/08, HETI-08-2097A, dated 07/10/08, HETI-
08-2103A,'dated 07/10/08 ' HETiO8-2131A, dated 07/10/08, HETI-08-2099B, dated
07/10/08, BETI-08-2100, dated ;10/08, HETI-08-2101, dated 07/10/08, BETI-08-
2102A, dated 07/10/08, HETI-08-2102B, dated 07/10/08, HETI-08-2097B, dated
07/10/08, HETI-OS-210313, dated 07/10/08, HETI-08-2104, dated 67/10/08, HETI-08-
2105, dated 07/10/08, HETI-08-210'6 dated 07/10/08, HETI-08-2125, dated 07/10/08,
I issued by Hurricane Engineering & Testing, Inc., and HETI-08-2131B, dated 07/10/08, al
signed and sealed by Candido F. Font, . E.
SubmittedunderpreviousNOA No. 0 4020.08)
G. OTHERS
1. Notice of A.cceptance No. 13-1217.22, issued to Lawson Industries, Inc, for their Series
3200 Outswing Aluminum Casement )indow - L.M.I., approved on 03/06/14 and
expiring on 03/04/19.
2. New Evidence submitted.
A. DRAWINGS
I Drawing No. L3200-0801 Rev D, titled "Series-200 Outswing Impact Casement Window",
sheets 1 through 07 of 07, dated 07/27/09 and las t revised on NOV21, 2017, prepared by
manufacturer, signed and sealed by Thomas J. Soltos, P.E.
Note: This revision consist of editorial changes of Fk, 17 (6& Edition) code compliance.
B. Test
1. None.
E-2
Ishhq 1. Chanda, P.E.
Product Control Examiner
NOA No. 17-1212.22
Expiration Date: March 04,2019
Approval Date: February 01, 2018
corporation, active and orgaiif
and filed at the Secretary of St 1111Statementletterofconformand
sealed by Thomas J. Sotos, P. E
Submitted underprevious NO,
Statement letter of no financial
Lawson Industries, Inc.
NOTICE OF ACCEPTANCE: EVIDENCE SUBM[ITTED
C. CALCULATIONS
1. None
D. QUALITY ASSURANCE
1. Miami Dade Department of Regulatory and Economic Resources (RER).
E. MATERIAL CERTIFICATIONS
1. Notice of Acceptance No. 14-0916.11 issued to Kuraray America., Inc. for their
SentryGlas@ (Clear and White) Interlayer", expiring on 07/04/18.
2. Notice of Acceptance No. 16-1117.01 issued to Kuraray America., Inc. for their "Trosffol@
Ultraclear, Clear, and Color FVB Interlayers" dated 0 1/19/17, expiring on 07/08/19.
3. Notice of Acceptance No. 15-1201.11 issued to Eastman Chemical Company (MA) for their
Saflex Clear and Color Glass Interlayers", expiring on 05/21/21.
F. STATEMENTS
1. Statement letter of conformance to FBC 2017 (61h Edition) and 'No fmancial interest" dated
11/17/17, prepared -by the manufacturer, signed and sealed by Thomas J. Sotos, P.E.
2. Statement letter dated 01/22/18 of the editorial drawing changes issued by Lawson Inc, signed
by Nelson Erazo, Senior design engineer.
G. OTHER
1. This NOA revises # 14-0908.20, expiring 03/04/19.
U
Ishaq 1. Chanda, P.E.
Product Control Examiner
NOA No. 17-1212.22
Expiration Date: March 04, 2019
Approval Date: February 01, 2018
E-3
ANCHORS.
A) 3 AT FRAME HEAD
C) 3 AT FRAME SILL
D) 5 AT EA. FRAME JAMB
C3
W o W
a:
La V uia - u0
C3
438\
3-6 TNI
Mall0D.L. in
N
u
r
F7
9
d
N
3
Lg CD
z t;
D
25- D.C. (14AX)
UAX)'
37-
WINDOW FRAME WIDTH
X" ELEVATION
LIMITED TO LOADS ON SHEET 5 OF 7)
Al J, 30 5/a'
V6d
ua
LL c t
rald—p. -4
General Notes:
1.) THIS WINDOW SYSTEM IS DESIGNED-AND-7ESTED, TO COMPLY WITH THE
REQUIREMENTS OF THE-FLORIOFA BUILDING CODE (2014 - 5th Edition &
2017 -6th-Editio-n)-INCLUDING HIGH VELOCITY HURRICANE ZONE (HVHZ)
AND-ASTM 1300-98. THIS PRODUCT IS IMPACT RESISTANT AND DOES NOT
REQUIRED SHUTTERS.
2.) iX or 2 X WOOD BUCKS SHALL BE INSTALLED AND ANCHORED SO THAT THE
BUILDING RESISTS THE SUPERIMPOSED LOADS IN ACCORDANCE WITH
REQUIREMENTS OF F.B.C. & TO BE REVIEWED BY BUILDING OFFICIAL
3.) ANCHORS SHOWN ABOVE ARE AS PER TEST UNITS. ON CENTER (O.C.)
ANCHOR SPACINGS WILL VARY WITH UNIT DIMENSIONS, AND THE NUMBER
OF ANCHORS REQUIRED, AS SPECIFIED ON THE LOAD TABLES AT SHEETS 5 & 6.
4.) ANCHOR CONDITIONS NOT DESCRIBED IN THESE DRAWING'S ARE TO BE
ENGINEERED ON A SITE SPECIFIC BASIS, UNDER SEPARATE APPROVAL AND
TO BE REVIEWED BY HOMING OMCIAL.
6.) SEE SHEET #3 FOR BILL OF MATERIALS AND DETAILS.
6.) SEE SHEET #5 & 6 FOR GLAZING DETAILS & OPTIONS AND CHARTS FOR
MAX. DESIGN PRESSURES.
7.) WOOD BUCKS IN CONTACT WITH CONCRETE MUST HE PRESSURE TREATED AND ANCHORED
BY OTHERS). PRIOR TO WINDOW INSTALLATION. (SEE SHEET #2 FOR DETAIL & NOTES)
8.) MATERIALS INCLUDING BUT NOT LIMITED TO STEEL SCREWS. THAT COME INTO
CONTACT WITH OTHER DTSSIMILAR MATERIALS SHALL MEET THE REQUIREMENTS
OF FLORIDA BUILDING CODE.
9.) EXT. & INT. FALSE COLONIAL MUNTINS ARE OFInONAL & AND ARE APPLIED W/ SILICONE
10.) FRAME SILL ANCHOR CLIPS TO BE MEASURED FROM THE INSIDE EDGE OF THE WINDOW FRAME
AND To BE LOCATED WITHIN A +/- 1/2" TOLERANCE.
TOTAL OF ANCHORS REQUIRED AT BILL TO BE THE SAME AS FRAME HEAD.
11.) SEE SHEET # 4 OF 10 FOR FLANGE PERIMETER CAULK/ INSTALLATION DETAIL.
12.) EXr- & INT. FALSE COLONIAL MUNTINS ARE OPTIONAL & AND ARE APPLIED W/ SILICONE
4
1 1 - I I
r'- 0"" '---11
74' - -
WINDOW FRAME-WIDT+r-
10" E1-U-A-'FI0N---(0X reversed)
TO WADS ON SHEET 6 OF 7)
ANCHOR CLUSTER
ANCHORS: SEE DETAIL #4 AT
A) 6 AT FRAME HEAD SHEET 7 OF 7
SI, (
FRAME SILL TYPICAL)
C) 6 AT FRAME :LL
MED) 4 AT EA. FRi EJAMB 'I
6'
MAX) rI.I.E.
T
WAAXX
DI
ANCHOR CLUSTER
ANCHORS, SEE DETAIL #4 AT
SHEET 7 OF 7A) 6 AT FRAME HEAD (FRAME SILL TYPICAL)
C) 6 AT FRAME SILL
i48\
A Al
Ln 5/8'
0. W
Wx :d X
q
0
Ic
aa?
z @E
Itxa!
ixed-Brac t
from and. mAx) B -44-
25* 0. . (MAX.)
1 all Fixed
at 8
zp. Lite
WHEN THE GAP BETWEEN THE WINDOW FRAME AND THE BUCK OR
MASONRY IS LESS THAN 1/8-, SHIMS ARE NOT REQUIRED.
ANCHORS NOU
ANCHORS TO BE #12 SMS OR WD. SCREWS INTO WOOD, OR
1/4' TAPCONS 0 APPROVED CONC. FASTENERS INTO CONC.,
WITH A MINIMUM OF 1 1/4' PENETRATION INTO WOOD OR
CONC. (REFER TO LOAD TABLES FOR QUANTITIES REQUIRED)
FYPICAL
T AlbM) ORN
MAX I
ELEVATION. .1 1 .1 FALSE: ..I
LIMITED TO LOADS ON SHEET 6 OF 7) MUNTINS ARE APPLIED W
V/ SILICONE AND ARE
AVAILABLE AS EIPTIONAL
PRODucrREVNED
Cox*4ft with twe wbrw
ft.1a.ze.&
A.W..N. r7-1212-w-
E,Fjftr 2,Iq
A / a."
kgMA%WPf.AO&CS"Mt
iWA A. R.,i-d t. CoMfy / 2010 FBC
N.W. 90 ST. LA WS ON
B. R-1 ..d R-W.n to ohmt 5 & 8 of 7
25 gy;T-3:
MEDLEY, FLORIDA 33166
X_T.Mrjz,:EM S , IIIT(:::. PH Na. (305) 696-8660
C. Revised to Comply w/ 2014 FBC M"MFUCTDRER OF QUAU27 ALUMM" ]PUBOYS AND CUSS DOORS
D, R"",d " C-Ply / 201 FBC NOA =.1 1 3203 1 LCNOA 08--Ol
OF n— ft,
N. ER&ZO 0-- 07/27/08 Series: 3200 Outswing Impact Casement Window
GENERAL NOTES & APPROVED ELEVATIONS (Y, XO or OX) 0. JR N. ERAZO 1L/OI/i7
3)
A'f— am f N—.
L320=0D-O8NQA-0I 00-0801 1 OF 7
1 5/32, ALL P.T, WOOD -Bucks
1/4' TAPCONS Wl---\ rnGE ENGINEERED SEPARATELY
1 1/4' MIN. CCINC,
D, STANCEIS
TO BE REVIEWED
EMBEDMENT BLUG. OFFICIAL (TYP.: 4EDGE 43
1 1/4'
MIN. E)dBEDJ
STUCCO
q..v
METAL LATH
BY OTHERS) STUCCO
UT UIMK)
1/4' MA'
FSHIM SP;2E
PERIM. CAULKING
B OTHERS
YP.) 1
EXTERIOR GRADE---/ 17 PERIMETER CAULKINI
15 BY OTHERS
TYP.) C,
24
22 23 17
A _/ 16
INTERIOR
GLASS
Ee 11
1 5/32' #
12 S.M,S. or WD. SCREW W/
EDGEISTANCE 1 1/4' MIN, WOOD EMBED
STUCCO—
BY OTHERS)
EXTERIOR
1/4' MAX
EXT. GRADE— ......... ..................... SHIM EXT, GRADE—
PERIM. CAULKING PERIM. CAULKING
TYP.) --
mm
CTYP.)
22'; 23' 6
STU 24
BY OTHERS) 'd E42L.)
A
A 4
4-
METAL LATH, STUCC 30
2 3/4' EDGE DISTANCE AND EXTERIOR GRADE
SHEATHING (BY OTHERS)
WHEN THE GAP BETWEEN THE WINDOW FRAME AND THE BUCK OR
MASONRY IS LEM THAN 1/8". SHIMS ARE NOT REQUIRED.
ANCHORS NOTE:
ANCHORS TO BE #12 SMS OR VD. SCREVS INTO WOOD, OR
1/4' TAPCONS or APPROVED CONC. FASTENERS INTO CONC.,
WITH A MINIMUM OF 1 1/4' PENETRATION INTO WOOD OR
CEINC. (REFER TO LOAD TABLES FOR QUANTITIES REQUIRED)
ex Wool]
BUCK (TYP.)
ALL WOOD FRAMING
ENGINEERED SEPARATELY
TO BE REVIEWED
BLDG. OFFICIAL (TYP.) F@
INTERIOR
1 5/32'
S
ALL WOOD BUCKS
ENGINEERED SEPARATELY
TO BE REVIEWED
43 BLDG. OFFICIAL (TYP.)
50
47 1 1/4-
MIN. Em8ED.)',,,--2X WOOD BUCK
ANCHORED TO CONC.
TO BE P.T. (TYP.)
17
1/4' MAK
SHIM SPACE
EXTERIOR INTERIOR
14 51
REVtW9PRODUCt
49 h"Adiog ewe
1/4' MAX.
HIM SPACE
BUCK (TYP.) ;L4O..) I N]E'l'
EXT. GRADE
M
PERIM. CAU INGLK
TYP.)
IX or 2X---
Z 44
P.T. WID. BUCK
2 3/4' EDGE DISTANCE
N.- Wwd to Comply / 21310 FBC LA WS ON -01 N.W. 90 ST.
Cr —Ij T
MEDLEY. FLORIDA 33166
T:S,rl_ PH No. (305) 696-8660m ... I W R le- to h..t 5 & 6 Lf 7
Ised to Comply w/ 2014 FBC MANUFACTURER OF QUAUTY ALUMMM WANDOWS AND GLASS DOORS
D,o. cl— 1 jp dougvi3WWoComply / 201 FBC ASSOM
Bw N. EFAZO D- 07/27/oa Series: 3200 Outswing Impact Casement Window
VERTICAL CROSS -SECTIONS, DETAILS & NOTESN. ERAZO 11/01/171
D
s- I P-d-A jhf— N-I,_ D-Av Avb- CASMENT3200-418NIIA-ol I L3200-0801 2 OF 7
k
Ik
PERIMETER CAULKING
FIXED VENT
S, -
ALL WOOD BUCKS
ENGINEERED SEPARATELY
TO BE REVIEWED
STUCCO BLDG. OFFICIAL (TYP.)
OVERALL FRAME
BY OTHERS)
PERIMETER CAULKING
OVERALL VENT
3
5 18 7 "
C 39 -
DAYLIGHT WID
EXTERIOR
21
13 GLA S
43
OPERABLE VE
TAPCON 14 51
its
MIN. EM
INTERIOR
42
4 -17- -21-- 17 16
WBEN THE GAP BLTMN THE WIND07 FRAME AND THE BUCK OR
MASONRY IS LESS THAN 1/8% SHIMS ARE NOT REQUIRED.
ANCHORS NOTE:
ANCHDRS TO BE #12 SMS OR WD, SCREWS INTO WOOD, OR
1/4' TAPCONS or APPROVED CONIC. FASTENERS INTO CONC.,
WITH A MINIMUM OF 1 1/4' PENETRATION INTO WOOD OR
CONC. (REFER TO LOAD TABLES FOR QUANTITIES REQUIRED)
STUCCO
BY OTHERS)
EXTERIOR
G w
OPERABLE VE
4""
PC5114TA 'ON
18
Mf- EMB
42
20
INTERIOR
16
17
16 17
@)
17 47
V
ALL WOOD BUCKS ENGINEERED SEPARATELY
TO BE REVIEWED BY BLDG. OFFICIAL (TYP.)
PJ WOOD BUCK NOT BY LAWSON IND.
MUST SUSTAIN IMPOSED LOA 1/4' MAX
7 -SHIM SPACE
METER CAULKINGPE "IPEP
05
36 3
EXTERIOR
21
12 16 48
LASS3334 >
43 43.-
35
PRODUCCREVISM
MIN. ED.) 14 51 M —Pbut with tLe Ft.-&
huwing C.I.
18 A
9n 21 35
2 41 .1 v
20.. 1 1 )
INTERIOR
47 47 11 D1
1 17 17 17 16 esh" Prod= C-ow
ALL WOOD BUCKS
32 ENGINEERED SEPARATELY
TO BE REVIEWED
BLDG. OFFICIAL (TYP.)
31
Rx ON A. ReVsed to Comply wl 2010 FEC
8501 N.W. 90 ST. LA WSUN ,EDLEY, FLORIDA 33166S. Renewal and Revision to sheet 5 & 6 of 7 E3 rrx eypy-_-3'xr-T <-_ PH No. (305) 696-8660
225
C. R-1-d to C..ply 2014 FEC AUNETAC7tFM OF QUALn7 ALUNDMU N3111DONS AMD CUSS DOdRS
M= D. Ra,6ed to C.nnply 2017 FBC I— —...'yMCN'WftW— 1 .12. 1'L=f1..-.11 97
4u Z Isms
0 N. EWO 07/27/os Series: 3200 Outswing Impact Casement Window
7 HORrZONTAL CROSS -SECTIONS. DETAILS & NOTES
f— lv. -08NOA-01 I" L3200-0801 3 OF''? D CASEMOTMOG
EXT. GRADE BACK 13EDD
TO BE APPLIED BEHIND
WINDOW FLANGE BY
INSTALLER (TYP.)
FACE CAULK -----I
BY OTHERS (TYP.)j I
LAWSON SERIES: 3200 CASEMENT WINDOW - BILL OF MATERIALS LIST
ITEM #DWG. NO. PART NO. QUANTITY DESCRIPTION
40 1 X VENT ANTI SAG VENT/SILL RAMP NYLON 6/6
41 1 X RANDLE LOCKIN - G HANDLE RACK PLATE
42 1 X VENT 5/16- INSECT SCREEN - OPTIONAL ALUMINUM FRAME
43 SEE ELEVATION FRAME INSTALLATION SCREWS #12 X 2 1/4- PH SMS
44 SEE ELEVATION FRAME SILL CUP SCREWS #12 X 1 1/2- PH SMS
45 SM-5504 SEE ELEVATION] FRAME/VENT ASSEMBLY SEALANT -
46 SEE ELEVAT10N FRAME INSTALLATION CAULKING EXTERIOR GRADE PERIMETER
47 L-3007 Ul-164 1 X ANCHOR FRAME HE&D/JAMB SHEAR PLATE 6063-75 ALUMINUM (3- L)
48 L-3009 Ul-159 AS REQD. GLAZING BEAD - 7/16- 6063-T5 ALUMINUM
49 2 X BRACKET FIXED VENT ATTACHMENT SCREW #8 x 1 1/4" FH./PHIL SDS.
50 8 X POST (N-POST ASSEMBLY SCREWS #10 X 1 1/4- PH SMS
51 DC-899 I AS RECID. GLAZING SEALANT SIUCONE
ALL WOOD BUCKS
ENGINEERED SEPARATELY
2X WOOD — &
TO BE REVIEWED
BUCK (TYP.)\ BLDG. OFFICIAL (TYP.)
f 12 S.M.S. or WD. SCREW
W,1 1 1/4' MIN. WOOD EMBED
INDOW FRAME
EXT. GRADE PERIMETER
CAULKING NOT BY
LAWSON INDUSTRIES',
TO BE APPLIED BY
OTHERS (TYP.)
EXTER113R FINISH
BY OTHERS CTYP.)
FRAME PERIMETER CAME DETAIL
SUBSTRATE.
CONCRETE OR
P.T. WOOD
BY OTHERS Clyp')
114' - ED.)
I
EXT. GRADE BACK BEDD
I[] BE APPLIED BEHIND
WINDOW FLANGE BY
INSTALLER (TYP.)
EXTERIOR GRADE
PERIMETER CAULKING
BY OTHERS (TYP.)
METAL LATH, STUCCO
2' AND EXTERIOR GRADE
SHEATHING (BY OTHERS)
SEE MULLION APPROVALS FOR MoI313CE'REVIS"
MULLION TYPE, SIZE AND MAX. ul,aw,41,g wull the Ft."
DESIGN PRESSURE LIMITATIONS. hwingCO& 27-
NOTE:
THE LOWER PRESSURES OF x
FIXED. CASEMENT WINDOW, OR
MULLION SHALL GOVERN.
12 S.M.S. X 1 1/4- L
SEE ELEV. FOR SPACING
4-
ZKO.) MIN. E t73Pt" I PERIMETER WINDOW FRAME
E SEALANT@) if C , " @
Ua; c o MULIJON ATTACHMENT DETAI
LAWSON SERIES: 3200 CASEMENT WINDOW - BILL OF MATERIALS MST
TTEu #DWG. NO.IPART NO. QUANTITY DESCRIPTION REMARKS
L-3001 UI-1 18 1 FRAME HEAD 6063-T6 ALUMINUM
2 L-3002 L11-1 15 1 FRAME SILL 6063-T6 ALUMINUM
3 L-3002 Ul-115 2 FRAME JAMB -HINGE SIDE 6063-T6 ALUMINUMr14L-3002 UI-115 2 FRAME JAMB -LATCH SIDE 6053-T6 ALUMINUM
5 L-3004 L11-1 19 2 VENT TOP RAIL 6063-T6 ALUMINUM
6 L-3004 UI-1 19 2 VENT BOTTOM RAIL 6063-T6 ALUMINUM
7 L-3004 Ul-1 19 2 VENT SIDE RAIL -HINGE SIDE 6063-TG ALUMINUM
8 L-3004 Ul-119 2 VENT SIDE RAIL -LATCH SIDE 6063-T6 ALUMINUM
9 L-3003 Ul-116 AS REO'D. IN -POST 6063-T6 ALUMINUM
10 L-3006 Ul-111 1 X ANCHOR FRAME SILL ANCHOR CUP 6063-T6 ALUMINUM (3- L)
11 L-3005 Ul-I 13 AS REO'D. FIXED LITE MOUNTING BRACKET 6063-T6 ALUMINUM (3- L)
12 L-3010 Ul-770B AS REDD. GLAZING BEAD - 5/16' 6063-T5 ALUMINUM
13 L-7531 L-7531 AS REOD. GLAZING BEAD BULB VINYL PVC VINYL
i 4 SM-5731 AS REOD. I GLAZING SEALANT - SIUCONE
15 L-3012 U-110 AS REQD. WEATHERSTRIPPING - FRAME/VEhTr PVC VINYL
16 L-3011 Ul-133 AS REQ'D. GLAZING BEAD 11/16- LAM./INSUL 6063-TS ALUMINUM
17 L-3013 12 CORNER KEY PER FRAME
18 L-3013 8 ER KEY PER VENT
12 L-3013 4 X POST
COR
CORNER KEY PER IN-POSr
20 8 FRAME ASSEMBLY SCREWS 10 X I- PH SMS
21 8 VENT ASSEMBLY SCREWS 10 X 1 1/4- PH SMS
22 2 X VENT 4 BAR 90* HINGES - STD. & H.D.
23 2 X VENT 4 BAR 45! HINGES - SID. & H.D.
24 AS REQD. HINGE MOUNTING SCREWS 10 X 1/2- P.H./PHIL B
25 1 X VENT VENT OPERATOR - DUAL or SINGLE
26 4/ OPER. OPERATOR MOUNTING SCREWS 10 X 3/,C- F.H./PHIL SOS
27 1/ OPER. STAINLESS STEEL 'C' TRACK
28 2/ TRACK TRACK MOUNTING SCREWS 8 X 1/2' F.H./PHIL SDS
29 1/ OPERATOR STUD BRACKET CONNECTOR
30 2/ BRACKET STUD BRACKET SCREWS 8 X 1/2- F.H./PHIL. SOS
31 1/ VENT LOCKING HANDLE
32 2/ LOCK LOCK HANDLE MOUNTING SCREWS 10-32 X 3/8' PH MS
33 1/ VENT LOCKING MULTI -POINT BAR
34 Ill X LOCK POINT TIE BAR NYLON GUIDES
35 2 X GUIDE NYLON GUIDES MOUNTING SCREWS 8 X 1 - PH./PHIL B
1/ LOCK KEEPER (ST. STEEL)
2/ KEEPER KEEPER MOUNTING SCREWS
4 SNUBBER 6063-T5 ALUMINUM
2/ SNUBBER SNUBBER INSTMIATION SCREWS 1#8 X 1/2' PH SMS
N.ftW-d t C..pty 2010 FUC
8501 N.W. 90 ST. LA WS ON MEDLEY, FLORIDA 33166
11-T3D tY'r1RII-E S,1111 PH N. (305) 696-8660
MANVE.ICITUM OF QUAL1117 AZUJUNDIf RMUNS AND CLASS DOORS
1 .d R-W- t hut 5 6 f 7
9—
OF: Q, N. ERAZO 67/2/os Series: 3200 Outswing Impact Casement Window
N. Ewo Dal OF MATERIALS LIST AND DETAILS
I— I pl f— . _' M'
200-0801 ls D CASEM..2,,-O8N0A-,, lor L3 4 OF 7
571-6- LAMINATED -GLASS COMPOSITION - TYPE
TrEu DESCRIPTION DETAIL
1 1/8' ANNEALED GLASS
2 D.0913' PVB INTERLAYERTRUSIFULPVRbyK~-y A-I- Inc
1SaRex PVB by Eastftn Chertical Co.
P-nm-
u'r
3
a
116" GLASS
14
DESCRWTION
GLASSt/8' KEAT-STRENCHTENED
ITE
oQ90' PVB INTERLAYER 5/16 -i ated
S &ftex PVII by E&Stm- Meracal Co
1/8' AT-STRENGHTENED GLASS 48
13
6/16" LAMINATED GLASS OMPOSITIMN TYPE
ITRU DESCRIPTION DRTAIL
1/8' HEAT-STRENGHTENED GLASL_
2 0.09V INTERLAYER gq
S-t,y(A.- Mt7t-Y' br
3 1/8' HEAT-S7RENGHTENED GLASS 1 14
9/16
A ING IT
7/16" Larainated
16 LAMINATED GLASS COMPOSITION E 'D"
DESCRUMON
3/16- ANNE LED GLASS
i DETAIL
Aw 16
0.090- PV9 INTERLAYER TC+
Saftex PVB by Eastman Cher4cat Co.
3 3/16m ANNEALED CLASS
11/16" U ATED GLASS COMPOSIT16N TYPE "E"
DESCRIPTION IIETAIL
ANNEALED GLASS
2 0.090' PVD INTERLAYER
S.fIO. PVB by E..t- Ch..I..t Co. 4 11,
3 1/8' ANNEALED GLASS
4 1/4' INSULATED AIR SPACE
5 So ANNEALED GLASS 3-
114
9,/16
GLA ING ITIE
11/16- Lanxinated&suld
LAMINATED GLASS TYPE -l DETAILS I
NOTE: WINDOWS WITH GLASS-1-1PES "E- INSTALIED ABOVE 30it- IN THE HVIiZ- THE I.G.
EXTERIOR LITE-SIIALL BE TEMPERED TO COMPLY WITH THE SMALL ML931LE IMPACT
RESISTANCE REQUIREMENTS (FBC-2017, Chapter 24 Section 2411.3.3.7).
320D Impact Casement Window
Confinurdfion- "V
aLIjN
U)
0
0
0
2060 24 1 72 2
W
2620 30 1 24 3
2630 30 36 3
N 2640 30 48 3
V) 2650 30 60 3
Of 2660 30 72 3
2820 32 24 3
2830 32 36 3'
0 2840 32 48- 3
2860 32- 1 60 3
2860- 32 72 3
3020 36 24 3
3030 36 36 3
3040 36 48 3
3050
F 30-60 1
36
36
60
72 1
3
3
GlassType"N' I GlassType"&' I GlassType"C' I GlassType"U' I GlassType"E'
5M6- Annealed Gass 1 SJ16" H.S. Gass - PVB 15116" RS. Gass -SGP 17116" Annealed Gass I 1IM6" Annealed Gass
59.0 1 59.0
5 59.0 1 59.0 70.0 1 82.0 70.0 1 70.0 1 73.0 010
6559.0 59.0 70.0 82.0 TP 82.0 70.0 73.0 7 1 73.0
2 59.0 59.0 70.0 B?,0- 70.0 82.0 70.0 73.0 70.0 1 73.0
3 59.0 59.0 70.0--82.0 70.0 82.0 70.0 73.0 70.0 73.0
4 59.0 59.0 70.0 BZO 70.0 82.0 70.0 73.0 70.0 73.0
5 59.0 _ 59.0 70.0 82.0 70.0 82.0 70.0 73.0 70.0 73.0
5 59-.o 59.0 70.0 820 70.0 82.0 70.0 73.0 70.0 73.0
2- 59.0 69.0 70.0 820 70.0 820 70.0 73.0 70.0 73.0
3 59.0 59.0 70.0 8zo 70.0 82.0 70.0 73.0 70.0 73.0
4 59.0 59.0 70.0 T2. 6 70.0 8ZO 70.0 73.0 70.0 73.0
5 59.0 59.0 70.0 820 70.0 820 70.0 73.0 70.0 73.0
5 59.0 59.0 70.0 820 70.0 62.0 70.0 73.0 70 O 73.0
2 59.0 59.0 70.0 820 70.0 8ZO 70.0 73.0 70.0 73.0
3 59.0 59.0 70.0 820 70.0 8ZO 70.0 73.0 70.0 73.0
4 59.0 590 700 2. 0 12. 2 20 0 73.0 70.0 73.0
5 590 S. 7.. 1 T2 1 7Z. 1 7.- 1 73.0 70.0 73.0
I
1 R
47367, Z
OF:
I. ..,Iy ./ 7010 FBC
B. Renewal and ReAeon to sheet 5
C. Re,(,..d I. C..ply 2014 FBC
D. R.,(-d I. Co.p, 2017 FBC
zv N. EWO 1 1
d B
FRODE1CfREVH*9
ft DIMP44as %irb
k6ang Cade
AK*Ivzjcr, N 1zfZ 2-2-
I- -Awhm
N.W. 90 ST. LA WS ON -M-ED,LEY, FLORIDA 33166
I1,T1::-x-Tn5,r1=zxr:: --3 1 IT g . ) PH No. (305) 696-8660
MAN17FACMIZIM Of QUA , FTY ALUMINUM WINDOWS AND CLASS DOORS
0- 1 C lPrM C.U JSAmM b Ift- RIf- 01 JR.W- 0. NCA ASSUM WNDOW 3200 LCNOA 08-01
Series: 3200 Outswing Impact Casement Window
GLASS & DP CHARTS AND GLAZING DETAILS FOR "X" UNITS
t IW- -. CASEMENM2GO-08NDA-01 W200-0801 6 OF 7
5/16" LAMINATED GLASS COMPOSITION TYPE "A"
rrEm DESC N
DETAIL
2
1/8& ANNEALED GLASS
0,090' PVB INTERLAYER
TRUSIFUL PV9 by Ku-y Amer(Co Inc.
or
14h
I I
13
S.ft.x PvB by Co.".. Ch-f-I Co.
3 1/8' ANNEALED GLASS
14 5116" LAMINATED GLASS COMPOSITION TYPE "B"
am DESCRIPTION DETAIL 9/16,
1
2
1/8' HEAT-STRENG147ENED
0.0901 PV8 INTERLAYER argjF
GLA ING IT
Soft- PVB by E..t- Co,
5/16- laminated
3 1/0' HEAT- TRENGHTENED Ass
48
13
16 LAMINATED CLASS COMPOSITION TYPE "C"
DrEm DESCRIPTION DETAIL
1 1/8' HEAT-STRENGHTENED GLASS
27 0.090' INTERLAYER
SentryGlass Intertayer by,
Kuror.y A .. Ic. In.
1/8' HEAT-STRENGHTENED ASS
14 51
9/16'_
GLA ING BITE
7 16 LAMINATED S COMPOSITION TYPE '*D" 7/16" Laminated
ITEM DESCRIPTION I DETAIL
1 3/16' ANNEALED GLASS 1 -1 AQ) 16 1320.090' PVII INTERLAYER TVSaftexPVBbyEQstmanh-i-t CO. 0401
3 3/16' ANNEALED GLASS
lIZ16- LAMINATED GLASS COMPOSITION TYPE E-
DES N DETAIL
1/8* ANNEALED GLASS
GUN' PV3 INTERLAYE 14 51
Saftex PvD by Eastmon ChenIcat CO, 9/16
3 1 S ANNEALED GLASS GLA ING BITE
I . INSLA-ATED AIR SPAM- 11/16" 1,Arn%ated/1nSuI&ted
5 11/8' ANNEALED CLASS
LAMINATED GLASS TYPES GLAZING OPTION
DETAILS
7
3200 Inipact Casen-ent Wndow CJass Type "N' GlassTypelrl I GlassTypia"C' I GlassType'V` I Glasi;Typia-'U'
Configuration: or "OK' BMW' Armealed Gass 06" H.S. Claw - PV131 W16"HS.GassSAP 1 7116" Annealed Gass 11116- AnuteaLed Gass
Size Wickh HDight Anchors bPM_]_ DP(-)
CO& I n) badfSill Jai Pd Pd Psf Ed I Pd I Pd 0 PSf
22. 37 26 4 2 70.0 70.0 70.0 73.0 70.0 820 70.0 7ao 70.0 73.0
LU 23 37 38.375 4 3 70.0 70.0 70.0 73.0 70.0 820 0 70.0 73.0
N 24 37 50.625 4 4 70.0 70.0 70.0 73.00 70.0 azo 70.0 73.0 70.0 7aO
25 37 63 4 4 70.0 70.0 70.0_ 00 70.0 820 70.0 73.0 70.0 73.0
32 53.125 26_ 4 2 70.0 70.0 70.0 73.0 70.0 820 70.0 73.0 70.0 73.0
0
33 53.125 38.375 4. 3 70.0 70.0 70.0 73.0 70.0 820 70.0 7aO 70.0 73.0
34 53.125 50-625 4 4 70.0 70.0 70.0 73.0 70.0 820 70.0 73.0 70.0 73.0
35 53.125 63 4- 4 70.0 - 70.0 70.0 73.0 70.0 820 70.0 73.0 70.0 73.0
0
0
D22 74 25 6 70.0 70.0 70.0 73.0 70.0 820 70.0 73.0 70.0 73.0
D23 74 38.375 6 a 70.0 70.0 70.0 73.0 1 70.0 82-0 70.0 73.0 70.0 73.0
D24 74 50.625 6 4 70.0 70.0 70.0 73.0 70.0 820 70.0 73.0 70.0 73.0
D25 74 63 6 4 70. LO 70.0 70.0 73.0 70.0 82.0 70.0 73.0 70.0 73.0
3020 36 24 4 2 70.0 70.0 70.0--- 7ao 70,0 820 70.0 73.0 70.0 73.0
3030 35 36 4 3 70.0 70.0 70.0 73.0 70.0 820 70.0 73.0 MO 73.0
3040 35 48 4 4 70.0 70.0 70.0 73.0 70.0 82.0 70.0 73.0 70.0 73.0
30M 36 60 4 4 70.0 70.0 70.0 73.0 70.0 820- 70.0 73.0 70.0 73.0
LU
4020 48 24 4 2 70.0 70.0 70.0 1 73.0 1 70.0 820 70.0 73.0 70.0 73.0
N 4030 48 36 4 3 M0 70.0 70.0 73.0 70.0 820 70.0 73.0 70.0 73.0
U) 4D40 48 48 4 4 70.0 70.0 MO 73.0 70.0 820 70.0 73.0 70.0 73.0
4050 48 60 4 4 70.0 70.0 70.0 73.0 70.0 820 70.0 73.0 7110 73.0
5020 60 24 5 2 70.0 70.0 70.0 73.0 70.0 820 70.0 73.0 70.0 73.0
5030 60 36 5 3 70.0 70.0 70,0 73.0 70.0 820 70.0 73.0 70.0 73.0
0 60 48 5 4 70.0 70.0 70.0 73.0 70.0 820 70.0 73.0 70.0 73.0
6050 61) 6D 5 4 70.0 70.0 70.0 73.0 70.0 820 70.0 73.0 70.0 73.0
6020 72 24 6 2 70.0 70.0 70.0 73.0 70.0 1120 70.0 73.0 70.0 73.0
6030 72 36 6 3 70.0 70.0 70.0 73.0 70.0 820 70.0 73.0 70.0 73T_
6040 72 48 6 4 70.0 70.0 70.0 73.0 MO 820 70.0 73.0 70.0 73.0
605D 72 60 6 4 70.0 70.0 70.0 73.0 MO 820 70.0 73.0 70.0 73.0
NOTE: WINDOWS WITH GLASS TYPES "E" INSTALLED ABOVE 3oft. IN THE HVHZ. THE I.G.
EXTERIOR LITE SHALL BE TEMPERED TO COMPLY WITH THE SMALL MISSUZ IMPACT
RESISTANCE REQUMMENTS (FBC-2017. Chapter 24 Section 2411.5.3.7).
PROIDUCIrRErdep
ftcvAPIY11`9Wkhd*FhQh
h.wageodeAoneplascaNal ?JZ.2z1-
Itspirulas bete
k
Nk-1,11
ft - A. R=d to r-.PIY / 2010 FBC
8501 NX 90 ST. LA.WSON
B. Rene -I end R.V.,. to sheet 5 & 6 of 7
1. 1
MEDLEY. FLORIDA 33166
11-T PH No. (305) 696-8660
C. Re%iged to Com IV w/ 2014 FBC
25 t
MUM7ACrUMR OF QUALF7Y ALUMU" WNDOWS AND CUSS DOORS
ITS
Ck--= 1 JP JILC.OAIcc,- D. ReAsed to Comply / 201 MC Ro. . R_..'
OF :ju w B.-
N. ERAZO jo Oo-7/;;/-- Series: 3200 Outswing Impact Casement Window
d 8,
IT. EWO iftu fi IL/01/17 GLASS & DP CHARTS AND GLAZING DETAILS FOR ')cx-ox-xo' uNrrs
n CASEUENMOO_WNOA__Gl I"' L3200-0801 6 OF 7
q) FRAME IN -POST RAIL
0 1218— F-i
L-3003
1435606.3-T6 ALUMINUM - - 4" 4 LY SCREWS
VENT RML
0 X 1 1/4-
FRAME HEAD0 0 MEWS4" 27- 1
IL SMS
L-3001 IL SMSH./PV VENT RAIL
6063-T6 ALUMINUM
rl
2.250
0.062
2.312
0.062- z__ L 17r.062
f 062
E.062 20
ANCHOR CLUSTER
21
1WJ.MB
I-
f Lb
3 HEAD/SILL TYPICAL) SIL VENT JA-UMB7—
INPOST
FRAME
G) 17
ANC OR DETAIL FRAME
18
CORNER DETAIL VENT RAIL CORNER DETAI1.875— 21
VENT RAIL FRAME IMPOST
FRAME SILL JAME 1-0.062 L-8004 SEE MULLION APPROVALS FOR
L-3002
6063-T6 ALUMINUM MULLION TYPE, SIZE AND MAX.
DESIGN PRESSURE LIMITATIONS.
6063-T6 ALUMINUM NOTNOTE- THE LOWER PRESSURES OF FIXED,
CASCASEMENT WINDOW OR MULL SHALL GOVERN
2250 -.
062 2.. 2 MAX1/4' SHIM
F.062 DOE0.062 I12 S.M.S. X 1 1/4" L_ 7 '
VSEEELEV. FOR SPACINGSEEEL0EFORSPAR FRAME S11
2.399 0.688 11
1_ ALL EE I1. ALL STEEL IN C014TACT WITHSTL
ALUM. TO BE PAINTED OR PLATED. ALUM To E FrMETAL2. STRUCTURES;
0.078 FRAME SHEAR PLATE:
L-3007
6063-T5 ALUMINUM
0.340
0. 120J
ST L 0 LLSTEELORALUM. 1/8" MIN. THICK)
A) STEEL Fy = 36 KSI MIN.
B) ALUMINUM : 6063-T5 MIN.
1
AS EMEILY SCREWS
0 X 1 1/4- kll_
P.H./PHIIL
1.231
SMS
ALUMINUM SNUBBER
L-3014
PERIMETER
SEALANT
WINDOW FRAME30B FRAME IMPOST DETAIL
0.377 6063-TS ALUMINUM METAL STRUCTURE ATTACHMENT DET FRAME & SASH CORNER ASSEMBLY DETAILS
FRAME SILL ANCHOR CMP 094 @
L-3008 rDM LITE MOUNTING BRACKET
6063-T6 ALUMINUM
1-0.094
70 L-3005
6063-T6 ALUMINUM
atmag Ck
Aftwom Na-L7- LZ 12- 2--2-
Ewkstion0 aate_.2' I
0.070J m, . L_ '_
2.794 FAdf PfObd CamW
GLAZING BRAD@5/16" Laminated
GLAZING BEAD GLAZING BEAD B 0 A. R.V..d t. C..ply 2010 FED
8501 N.W. 90 ST. LA uWS"NILRemwalendReWslontosheet56of7L-3010 or L-7708
11/16' I-ulated/Laminated
L-30il or LU-133
7/16' I—ffiated
L-3009 or MI-169 P-25
MEDLEY, FLORIDA 33166
PH N. (305) 696-8660
6063-T5 ALUMINUM 6063-TS ALUMINUM 6063-T5 ALUMINUM
I-
C. Reviged t, Comply w/ 2014 FBC MANUFACTURER OF QUAUZY ALUMJMW nNDOYS AND CL4SS DOORS
D. R.0-d t. Cmply w/ 2017 FBC NOA ASSEMBLY WNDOW 32000.05 0
0.801
0.391
a. 15
0
LO-gO-qO.6 J
AI
or
V1.
2'_ sw N. FRA20 IDW. 07/27/08 Series: 3200 Outswing Impact.Casement Window
A—d Dr. N. ERM 1. - llr0l/17
0 0.050 0.688L
6
EXTRUSION CROSS -SECTIONS, & ASSMLY DETAILS
CASEMENr3200--CaNOA-01 L3200-0801 I F 7
0.115
I IDAT