Loading...
HomeMy WebLinkAboutREVISION 7-2-19tsr - f-.,,4* i- q—. ,, OFFICE USE ONLY: SCANNEDD.s(TE FILED: I \ 3' \" PERNUT# REVISION FEE: lc - % RECEIPT# R E C Ez- I—VE:- 5 - — PLANNING & DEVELOPMENT SERVICES LL—' SGANNW BUILDING& CO E REGULATION DIVISION - L' V JU2300VIRGINIAAVENUEJUL FORT PIERCE, FL 34982-5652 Luc772) 462-1553 ST, Lucie CoUrIty A I FOR BUILDING PERMIT REVISIONS PROJECT INFORMATION LOCATION/SITE ADDRESS: 4422 HIGHWAY AIA - QUEENS ISLAND PRESERVE .—C-MISTAT LOT3 DETAILED DESCRIPTION OF PROX REVISIONS: Adjustments to frangible slab design per contractor construction CONTRACTOR INFORMATION: STATE of FL REG./CERT. #: CGC047289 BUSINESS NAME: UBALDO BLANCO GO INC QUALIFIERS NAME: UBALDO BLANCO ADDRESS: 437 GOLDEN ISLE drive APT-8F CITY: HARMONY STATE: PHONE (DAYTIME): (786) 512-5717 ONVNER/BUILDER INFORMATION: NAME: VENETIAN ADMINISTRATION LLC ADDRESS: 7400 FLAGLER AVENUE CITY: MIAMI PHONE (DAYTIME- ARCHITECT/ENGINEER INFORMA NAME: KNIGHT MCGUIRE & ASSOCIATES ST. LUCIE CO CERT. #: 30970 ZIP: 33009 FAX: STATE: FLORIDA ZIP: 33144 FAX: ADDRESS: 80 ROYAL PALM POINTE SUITE 401 CITY: VERO BEACH STATE: FLORIDA ZIP: 32960 PHONE (DAYTIME): (772) 569-5505 FAX: (772)569-1455 Revised 06130117 SLCCC.- 9123109 nffw""EV ISION F11 Knight, McGu e & Associates, hic. Consulting Engineers and Planners 80'.Royal Pahn Pointe, Suite 401 Vero Bea* Florida 32960 David S. Knight, P.E. Phone: (772) 569-5505 Scott B. McGuire, P.E. Fax: (772) 569-1455 June 24, 2019 Planning & Development Department RECEIVED Building & Code Regulation Division St. Lucie County J U L 0 2 "2192300VirginiaAvenue Ft. Pierce, FL 34982 ST. Lucie County, Pci-mitting J RE: AcquaVista Lot 3 (a.k.a. Queen Island Preserve, Block A, Lot 3) PERMIT #1901-0543 To Who It May Concern: The following clarifications and modifications for the above mentioned project/permit numberI shall be completed in accordance with the variations from the permitted design, as detailed below: 1. The following detail is provided for floating, fra lgible slabs to be constructed where rShearWallFootingsandTransitionCapswerepoured independently of the slabs. All cracking and settlement control is the responsibility of the contractor. refer to TYPICAL WALL I 2"Jeep x 244,vode THICKENED EDGE (5heet 5-10) for I'RANG151-I! - NO STEEL REINFORCEMENT— construction sper 300op5i flt3ffRME5H CONCRETE - TYPICAL WHERE MNGIDLE SLAB ABUTS PERMANENT FOUNDATIONS (51-lffARWALL FOOTINGS AND TRANSITION CAPS) 4' thick 3000p5i CONCRETE 5LA13 - FIBEKME51-i REINf. - FRANGIBLE - SAW CUT into 5&max. SECTIONS - refer to plans for cut locations T termte: J r'Md 4r iriia' fill den 4c;ted 95% dry den5lty) 224'x 24"deep FOOTING wl (3) #5'5 CONT, (top bottom) #3 5TIRR.UP5 @ I G" O.C. - TYPICAL at ALL SHEAF, WALI-5 * ELEVATOR WALLS Cordially, David S. Knight, P.E. FL Reg. No. 41060 12019 C- APPLY WATERPROOFING TO nry MASONRY WALLA MINIMUM 12' ABOVE ADJACENT 1`11,1151-1 GRADE NOT REQUIRED WdffRE FLOOR ELEVATION IS G'OR. MOPE ABOVE FIN15H GRADEN I'lNeN GRADE 7, @ edge of n (BELOW) PAN5ION MATERIAL per CONTRACTOR. P 4"3000p5i CONCRETE OVERFOUP GxG 10/ 10 W.W,M - 2-widp- STRIP) STANDARD HOOK 3 MIIN,PILE 22'. EMBEDMENT MI I rl., TYPICAL AUGER. CAST FILE I., . . . ...... I ...... ...... 110 1-IfticitREFERTODETAILS REVIEWED FOR CODE COMPLiANCE ST. LUCIE COUNTY BOCC