Loading...
HomeMy WebLinkAboutVENTS E'RINSULATE'D t1 ONO iTV f F1PURflfjjN/ This series of vents is ideal for a . reas. quiring flood. venting protection but no natura air ventilation. The flood door contains a 2" insulate, cote- that n', " has an R-value of 8.34 and the ventJ ame is lined with felt weather stripping, helping to keep the enclosure as insulated from the elem6h'ts' -as possible. IDEAL FOR. Garages Full height enclosures (e.g.. walk, uts) Conditioned crawlspaces Storage facilities Metal buildings Foyers MAR, 2 U-019 Flood Vent Li 1540-520 61,.-Sta-cker 1540-521 Stacker Models are twice as efficient as a single unit and are a great solution for large amounts of square footage, and in situations Where there is not enough wall space to fit in Single units. Wood Wal I 1540-570 Wood Wall Models are designed to fit between studs spated'at 16" on center Pre -drilled slots in the four corners on the vent flange make for an ea' Installation. SY For more information on Flood ProtOctioh SolUtions, Smart Vent 430 Andbro Drive,,Unit 1 - Pitrnan, NJ 06b7i Website: www.stilartvent.com Tel: (8771 44f_8368" Email:Anfol SMART VENT Foundation Flood Vents A? 1,k mmm-- Eel MIN171 - MODEL NUMBER FLOOD COVERAGE VENT SIZE ROUGH OPENING Smart VENT 877— 441— 8368 vww.smartvent.com. INSTALLATION INSTRUCTIONS DETAILS MODEL 1540-520 FLOODVENT INSULATED M "-Is 1. REMOVE VENT DOOR FROM VENT FRAME. (TURN UPSIDE DOWN, ROTATE. BOTTOM OF DOOR OUTWARD AND SLIDE OUT) 2. PREPARE A CLEAN 16.25" WIDE BY 8.25" HIGH ROUGH OPENING (APPROX. 1 BLOCK WIDE X 1 BLOCK HIGH) FOR EACH VENT. ENSURE THE BOTTOM OF THE ROUGH OPENING IS NO MORE THAN 12" ABOVE THE FINISHED GRADE. 3. APPLY A BEAD OF HURRIBOND GRIP & SEAL OR EQUIVALENT ADHESIVE AROUND THE BACK OF THE FLANGE ON THE VENT FRAME. (FIG. 2) 4. INSERT INSTALLATION CLIPS INTO THE TWO SLOTS ON THE TOP AND TWO SLOTS ON THE BOTTOM OF THE FRAME. 5. THE SPRING ARM OF THE CUPS SHOULD BE ON THE OUTSIDE OF THE VENT FRAME. COMPRESS THE BOTTOM TWO CLIPS AND BEGIN SUPPING THE FRAME INTO THE OPENING. ENSURE THAT THE BOTTOM CLIPS ARE IN THE OPENING BEFORE ALLOW THEM TO DECOMPRESS. 6. WITH THE FRAME NOW IN THE OPENING, AND THE 6OTrom—SPRING-S--]N-PIACE;-COMPRESS-THE-TOP-SPRINGS-AND-PUSH-THE—VENT-FRAME-INTO THE OPENING COMPLETELY UNTIL THE FRAME IS FLUSH WITH THE WALL 7. RE -CHECK THAT FRAME IS SQUARE AND SLOTS ARE CLEAR OF DEBRIS, AND CAULK. 8. INSTALL THE DOOR INTO FRAME BY. GRASPING THE BOTTOM OF DOOR (WITH FLOAT PINS DOWN) AND FRONT (SMALL SCREEN IN FRONT). SLIDE DOOR INTO FRAME AND ROTATE UNTIL IT IS LATCHED. 9. TO'OPEN THE DOOR INSERT TWO CREDIT CARDS INTO THE FLOAT SLOTS AS SHOWN IN THE DIAGRAM. THIS WILL UNLATCH THE DOOR FOR REMOVAL AND CLEANING. DETAIL SPECIFICATIONS: MATERIAL- STAINLESS STEEL OPERATION: AUTOMATIC NON -POWERED ACTIVATION AND OPERATION INSTALLATION: SECURED W/ 4 STAINLESS STEEL INSTALLATION CLIPS INCLUDED AND AN ADHESIVE HYDROSTATIC RELIEF: 200 SQ. FT PER VENT REQUIREMENTS: MINIMUM OF 2 VENTS PER ENCLOSED AREA MOUNTED ON AT LEAST TWO DIFFERENT WALLS COLORS: STAINLESS (STANDARD) EXTERIOR POWDER COATED WHITE, WHEAT, GRAY, AND BLACK (AVAILABLE) MEETS THE REQUIREMENTS FOR ENGINEERED OPENINGS AS SET FORTH BY- FEMA, NFIP, ICC, & ASCE SUPPORTIVE DOCUMENTS, TS 1-08, 44CFR 60.3(C)(5). ASCE 24-14 ICC EVALUATION # ESR-2074 SHEET 2 OF 2 FRAME FIGURE 2 SIDE VIEW DETAIL DIAGRAM MODEL 1540-520 FLOOD VENT INSULATED 16 1/4- R/O CLIP SLOTS USE TWO TOP AND TWO BOTTOM 1/4' FLOAT SLOTS R/O 4 GRIP 8c SEAL FIGURE 1 00ATION FRONT VIEW 4 FIGURE 3 12" MAX FROM CLIPS INSTALLED: TWO ON SIDE VIEW FINAL GRADE T, 4< TOP TWO ON BOTTOM T<:7 MCA. 430 ANDBRO DR UNIT 1041111116;~ PITMAN NJ 09071 SMART VENT& 877-441-8368 FLOOD VENT INSULATED WWW.SMARTVENT.COM - MODEL 1540-520 SIZE I DWG NO. RE A 1540-520 E mw ot-01-19 I Q.C= I — 0