iTV f F1PURflfjjN/
This series of vents is ideal for a . reas. quiring
flood. venting protection but no natura
air ventilation.
The flood door contains a 2" insulate, cote- that
n', " has an R-value of 8.34 and the ventJ ame is lined
with felt weather stripping, helping to keep the
enclosure as insulated from the elem6h'ts' -as possible.
IDEAL FOR.
Garages
Full height enclosures (e.g.. walk, uts)
Conditioned crawlspaces
Storage facilities
Metal buildings
Foyers
MAR, 2 U-019
Flood Vent Li
1540-520
61,.-Sta-cker
1540-521
Stacker Models are twice as efficient
as a single unit and are a great solution
for large amounts of square footage,
and in situations Where there is
not enough wall space to fit in
Single units.
Wood Wal I
1540-570
Wood Wall Models are designed to fit
between studs spated'at 16" on center
Pre -drilled slots in the four corners on
the vent flange make for an
ea' Installation. SY
For more information on Flood ProtOctioh SolUtions,
Smart Vent 430 Andbro Drive,,Unit 1 - Pitrnan, NJ 06b7i
Website: www.stilartvent.com Tel: (8771 44f_8368" Email:Anfol
SMART VENT
Foundation Flood Vents A?
1,k
mmm--
Eel
MIN171 -
MODEL NUMBER FLOOD COVERAGE VENT SIZE ROUGH OPENING
Smart VENT
877— 441— 8368
vww.smartvent.com.
INSTALLATION INSTRUCTIONS
DETAILS
MODEL 1540-520
FLOODVENT INSULATED
M "-Is
1. REMOVE VENT DOOR FROM VENT FRAME. (TURN UPSIDE DOWN, ROTATE. BOTTOM OF DOOR OUTWARD AND SLIDE OUT)
2. PREPARE A CLEAN 16.25" WIDE BY 8.25" HIGH ROUGH OPENING (APPROX. 1 BLOCK WIDE X 1 BLOCK HIGH) FOR EACH VENT. ENSURE THE BOTTOM OF THE ROUGH OPENING IS NO MORE
THAN 12" ABOVE THE FINISHED GRADE.
3. APPLY A BEAD OF HURRIBOND GRIP & SEAL OR EQUIVALENT ADHESIVE AROUND THE BACK OF THE FLANGE ON THE VENT FRAME. (FIG. 2)
4. INSERT INSTALLATION CLIPS INTO THE TWO SLOTS ON THE TOP AND TWO SLOTS ON THE BOTTOM OF THE FRAME.
5. THE SPRING ARM OF THE CUPS SHOULD BE ON THE OUTSIDE OF THE VENT FRAME.
COMPRESS THE BOTTOM TWO CLIPS AND BEGIN SUPPING THE FRAME INTO THE OPENING. ENSURE THAT THE BOTTOM CLIPS ARE IN THE OPENING BEFORE ALLOW THEM TO DECOMPRESS.
6. WITH THE FRAME NOW IN THE OPENING, AND THE 6OTrom—SPRING-S--]N-PIACE;-COMPRESS-THE-TOP-SPRINGS-AND-PUSH-THE—VENT-FRAME-INTO THE OPENING
COMPLETELY UNTIL THE FRAME IS FLUSH WITH THE WALL
7. RE -CHECK THAT FRAME IS SQUARE AND SLOTS ARE CLEAR OF DEBRIS, AND CAULK.
8. INSTALL THE DOOR INTO FRAME BY. GRASPING THE BOTTOM OF DOOR (WITH FLOAT PINS DOWN) AND FRONT (SMALL SCREEN IN FRONT). SLIDE DOOR INTO FRAME AND
ROTATE UNTIL IT IS LATCHED.
9. TO'OPEN THE DOOR INSERT TWO CREDIT CARDS INTO THE FLOAT SLOTS AS SHOWN IN THE DIAGRAM. THIS WILL UNLATCH THE DOOR FOR REMOVAL AND CLEANING.
DETAIL SPECIFICATIONS:
MATERIAL- STAINLESS STEEL
OPERATION: AUTOMATIC NON -POWERED ACTIVATION AND OPERATION
INSTALLATION:
SECURED W/ 4 STAINLESS STEEL INSTALLATION CLIPS INCLUDED AND AN ADHESIVE
HYDROSTATIC RELIEF: 200 SQ. FT PER VENT
REQUIREMENTS: MINIMUM OF 2 VENTS PER ENCLOSED AREA MOUNTED ON AT LEAST TWO DIFFERENT WALLS
COLORS: STAINLESS (STANDARD)
EXTERIOR POWDER COATED WHITE, WHEAT, GRAY, AND BLACK (AVAILABLE)
MEETS THE REQUIREMENTS FOR ENGINEERED OPENINGS AS SET FORTH BY-
FEMA, NFIP, ICC, & ASCE
SUPPORTIVE DOCUMENTS, TS 1-08, 44CFR 60.3(C)(5). ASCE 24-14
ICC EVALUATION # ESR-2074
SHEET 2 OF 2
FRAME
FIGURE 2
SIDE VIEW
DETAIL DIAGRAM
MODEL 1540-520
FLOOD VENT INSULATED
16 1/4- R/O
CLIP SLOTS USE TWO TOP
AND TWO BOTTOM
1/4'
FLOAT SLOTS
R/O
4
GRIP 8c SEAL FIGURE 1
00ATION FRONT VIEW
4
FIGURE 3 12" MAX FROM
CLIPS INSTALLED: TWO ON SIDE VIEW FINAL GRADE
T, 4<
TOP TWO ON BOTTOM
T<:7 MCA.
430 ANDBRO DR UNIT 1041111116;~ PITMAN NJ 09071
SMART VENT&
877-441-8368 FLOOD VENT INSULATED
WWW.SMARTVENT.COM - MODEL 1540-520
SIZE I DWG NO. RE
A 1540-520 E