HomeMy WebLinkAboutBUILDING PLAN -PAGE 1-13Q I REVISIONS BY DATE permit sets GS 10.5.2018 1 st Bldg Comments GS 3.12.201� TOP CAP ON 2" x 2" TUBE SAFETY GLASS F PANEL 1 1/2" x 1 1/2" SQUARE 3j/2' PICKET (TYP,) NOTE: ALL FASTENERS FOR RAIL ATTACHMENTS TO BE STAINLESS STEEL NOTE: TOP CAP ON PICKET SPACING TO 2"x2" TUBE REJECT 4" DIA, SHERE NOTE: ALL FASTENERS FOR RAIL ATTACHMENTS TO BE STAINLESS STEEL 08 ALUMINUM BALCONY GUARD DETAIL 3/4 V-0" 04 ALUMINUM GUARD DETAIL Al 4" MIN EDGE DISTANCE 411 RAILING POST (REFER TO SHOP DRAWINGS FOR SIZE & LOCATIONS) MIN POST EMBEDMENT = 4" 3 1/4" DIA x 4" DEEP HOLE INTO CONCRETE, FILL HOLE W/ EPDXY BONDING/GROUTING ADHESIVE (SIKADUR 32 HI -MOD) 4 In < 07 EXTERIOR RAILING ATTACHMENT RECOMMENDED WATERPROOFING BE PROVIDE AT THE COLD JOINT BETWEEN THE DECK AND THE CMS TO PREVENT WATER INTRUSION. RECOMMEND WATERPROOFING BE PROVIDED 1" BEYOND THE SLIDING GLASS DOOR PERIMETER SEALANT TOWARD THE INTERIOR; 1" ON THE DECK OUT FROM THE RETURN; 2" OUT AWAY FROM THE CMU; AND SIX TO EIGHT INCHES UP THE EXTERIOR FACE OF THE WALL RECOMMENDED 3/4" X 3/4" SILICONE CANT PRIMER. IF REQUIRED CANT BEAD TO BE PROVIDED AFTER STUCCO AT THE JUNCTION OF THE CONCRETE SLAB AND THE EXTERIOR FACE, CANT BEAD TO TIE INTO THE SLIDING GLASS DOOR PERIMETER SEALANT. 1" BEYOND SLIDING GLASS DOOR PERIMETER SEAL —��rCONCRETE BLOCK STUCCO--,,,.. SLIDING GLASS DOOR FRAME SILL )/2" DIA SOLI ALUM ROD (TYP.) 1 1/2" x 2" PICKET 2" x 2" SQ PICKET -1AP @ DST 2x4 NAILED TO FLOOR TRUSSES ((2) 16d each truss) No. 6 x 1" GAILV SCREWS - @ 32" O/C TO TOP RUNNER No. 6 x V GALV SCREWS @ 32" O/C TO BOT PLATE P.T. 2x4 wl 1/4" x 3" CORROSION RESISTANT-�\ TAPCONS @ 16" O/C INTERIOR NON D3 3%" METAL RUNNER TRACKS (25 gal TOP & BOT 61 3%" METAL STUDS (25 ga) @ 16" O/C NORMAL MATERIALS DESIGN FLOOD ELEVATION (DFE) SEE PLANS FLOOD PROOF MATERIALS (CLASS 4 OR 5 PER FEMA TECHNICAL BULLETIN #2) THIS DESIGN ALLOWS THE METAL FRAMED WALL TO BREAKAWAY FROM THE PERMANENT TOP& :111 BOT 2X4 RUNNERS WITHIN THE 10-20 PSF LOADIM 'I ilI RANGE WITHOUT HARM TO THE ELEVATED PORTI fl; OF THE BUILDING OR SUPPORTING FOUNDATION ING ONSTRUCTION 1 1/211 1 1-011 )D BA STANDING SEAM METAL ROOF LUSI ERB 0 REJECT (.032 ALUM 5V CRIMP) ERSPHERE OVER VERSASHIELD ON PEEL & STICK MEMBRANE OVER 30# FELT TIN TAGGED TO APA 40/20 19132" EXPOSURE 1 PLYWOOD POST of V-01 NTS 03 WOOD BALCONY RAI LING DETAIL 3(4 GRASPABLE TOP RAIL PER N.F.P.A. 101 5-2.2.4.5 (C) R 311.5.6 HANDRAILS SHALL BE PROVIDED ON AT LEAST 1 SIDE OF EACH STAIRS & SHALL BE CONTINUOUS FOR THE FULL LENGTH OF THE FLIGHT HARDWOOD BALUSTERS SPACED TO REJECT , Z// 4" DIAMETER SPHERE TREADS CANT BEAD U) WOOD STAIRS —HARDWOC D MEMBRANE DECORATIVE RISERS WATERPROOFING /4' RECE /4" RECESS ARID HARDWOOD SKIRTBOARD VULKEM TRAFFIC COATI N TOBE-Z G USED ON BALCONY SURFACES UPPER STAIR - RISE=7.09", RUN=11" '74 LOWER STAIR - RISE=6.95", RUV11" 06 'TS WATERPROOFING BALCONY NTS 02 STAIR RAIL DETAIL 3/4 If 1 NON-SKID FLOORING ON EPDXY BASED SETTING MATERIAL :1 1 ['��3%" L IdG & GROUT OVER TRAFFIC COATING METAL RUNNER (NO PHOSPHATE BASED MORTAR) FOR FIRE RATED & ADJACENT WALL TRACKS (25 g TOP & BOT TOP & BOT RUNNERS TO BE FASTENED TO CEILING & FLOOR @ MAX 24" O/C wl 5/8" TRAFFIC COATING EMBED NAILS OR SELF TAPPING SHFFT 1� 5 BULLNOSE METAL SCREWS FOR METAL TO METAL 1� I S EDGE 3%" METAL ST JDS 4 (25 ga) @ 24" G/C < 4 < < 4 WATER DRIP - GROOVE SMOOTH STUCCO FINISHED BALCONY 05 1 BALCONY EDGE DETAIL 5/8"GYPBOAqDw/A LEVEL 4 FINIS� OR 5/8" DUROCK (M WET AREAS SEE ANCHOR SCHEDULE ON STRUCTURAL PLANS FOR ROOF TIE DOWNS EAM @Lo-+P-1 Il E4 P A. F. F. SEE SHEET A802 FOR-/ TRUSS END DETAILS IS 10P 0 AM & 1ST FLO ELE� OR V 0 �;E 8"x16" BOND BEAM---' (SEE STRUCTURAL PLANS) FILLED CELLS w/ VERT. DOWELS (SEE STRUCTURAL PLANS FOR SIZES & LOCATIONS) 3/4" RECESS GARAGE/LOBBY (0). ELEV-14'-10"/-11'-0" GRAIDEVARIES BATT INSULATION =OR WALLS BETWEEN CONDIT ONED and UNCONDITIONED 'FACES, AT OPT. LOCATIONS F OR SOUND- GEN!ERAL NOTE SPECIFICATIONS: SEE PLANS -ALL CONCRETE SHALL BE OCEAN MIX -ALL NAILS SHALL BE GALVANIZED -ALL FASTENERS SHALL BE STAINLESS STEEL NTS 01 INTERIOR FRAME WALL (NON BEARING) 1 11/211 = 1 1-011 D1 ITYPICAL2-STORY WALL SECTION MIN R-20 1/2 lb. PER CUBIC FOOT SPRAY APPLIED OPEN CELLED FOAM INSULATION THAT PASSES ACC 377 APPENDIXWWITHOUT A COATING 12 41/2 F INTERIOR WALL & CEILING FINISH NOTES: 1. ALL INTERIOR WALL & CEILING FINISHES TO COMPLY w/ FBC 2017 R302.9 FOR FLAME SPREAD & SMOKE DEVELOPED INDEX. 2. FLAME SPREAD INDEX NOT TO EXCEED 200. 3. SMOKE DEVELOPED INDEX NOT TO EXCEED 450. INSULATION NOTES: 1. ALL INSULATION TO COMPLY W/ FBC 2017 R302.1 0 FOR FLAME SPREAD & SMOKE DEVELOPED INDEX. 2. FLAME SPREAD INDEX NOT TO EXCEED 25. 3. SMOKE DEVELOPED INDEX NOT TO EXCEED 450. STANDING SEAM METAL ROOF (.032 ALUM 5V CRIMP) OVER VERSASHIELD ON PEEL & STICK MEMBRANE OVER 30# FELT TIN TAGGED TO APA 40/20 19/32" EXPOSURE 1 PLYWOOD SEE ANCHOR SCHEDULE ON STRUCTURAL PLANS FOR ROOF TIE DOWNS F EAM L@0-+P-293 -0 P A. F. F. R-/SEE SHEET A802 FO TRUSS END DETAILS MIN R-20 1/2 lb. PER CUBIC FOOT SPRAY APPLIED OPEN CELLED FOAM INSULATION THAT PASSES ACC 377 APPENDIX'X'WITHOUT A COATING 12 41/2 Y8" GYPSUM BOARD CLG ATTACHED TO BOT CHORD OF TRUSSES -P.T, 1x3 FIRESTOP CONT. -MIN 8"x8" BOND BEAM (SEE STRUCTURAL PLANS) 445�2G. ROOF UNES @ 24" O/C A -PT I�A('TWT RATRUN RESTRAINTS ?0 - 3/4" GYPSUM TOPPING ON Y4" T&G FiqP[E.Cz RUCTURAL PLANS) PLYWOOD GLUED & SCREWED TO FLOOR TRUSSES, (PLACE PLYWOOD R-16YP OM 66AK5 i5n;M!' CHED LOP IF PERPENDICULAR TO TRUSSES) TO BOT CHORD OF TRUSSES @ _�EAM & 2ND FLOOR 3_0 A.F.F. 0- P.T. 1x3 FIRESTOP CONT. 4- 24" DEEP PRE-ENG FLOOR T 7 9 TRUSSES @ 24" O/C MAX 14i MIN 8"x8" BOND BEAM 8"x`16" BOND BEAM--� (SEE STRUCTURAL PLANS) —MIN R-20 1/2 lb. PER CUBIC FOOT LIED (SEE STRUCTURAL PLANS) npp:N r.F:i i F:n ES ACC 377 APPENDIX'X'WITHOU7 A �-%" GYPSUM BOARD CLG ATTACHED L F7 CHORD OF TRUSSES OR v METAL FRAMING @ SOFFITS P.T. 1x3 FIRESTOP CONT. D I -A �nmy -DT `!�Arr)!,IT GYPSUM TOPPING ON Y4" T&G PLYWOOD GLUED & SCREWED TO FLOOR TRUSSES. (PLACE PLYWOOD PERPENDICULAR TO TRUSSES) W - 9 c5j 24" DEEP PRE-ENG FLOOR TRUSSES @24" O/C MAX T SP Y APF —MIN R-20 1/2 lb. PER CUBIC Foc r sp Y AP -N Q A MAC QPF -ELLED FOAM III__ ACC 377 APPENDIX'X'WITHOUI A :;OAT G - GYPSUM BOARD Cl G ATTACHED TO BOT CHORD OF TRUSSES OR NOTE: P.T. 2X4 FRAMING AROUND ALL SHOWER OPENINGS METAL FRAMING 9,-jUl­-l­1 I b P.T. 1 x3 FI RESTOP CONT. STAPLED TO P.T. 1x2 FURRING @ 24" O/C 5/8" GYP BOARD OVER R4.1 FI-FOIL INSULATION I P.T. 1 X4 CONT. L - - - - - - 4 III III H SEE STRUCTURAL PLANS I FOR PILING, GRADE BEAMS, J FOUNDATION DETAILS LIED �.EAM & 1ST FLOOR PC 6B El LE V O� 8"xl6" BOND BEAM­`� (SEE STRUCTURAL PLANS) FILLED CELLS w/ VERT. DOWELS (SEE STRUCTURAL PLANS FOR SIZES & LOCATIONS) 3/4" RECESS GARAGE/LOBIBY (a) \-w ELEV-14'-10"/-11'-0" GRADE VARIES GENERAL NOTE SPECIFICATIONS: -ALL CONCRETE SHALL BE OCEAN MIX -ALL NAILS SHALL BE GALVANIZED -ALL FASTENERS SHALL BE STAINLESS STEEL a all 0 see 0 a 0 0 NJ MFM w sme Muni MI ME 0 0 1:1 14111MV, 0 1 0, 0 MON 3/411 V-0" I D2 I TYPICAL 3-STORY WALL SECTION METAL FRAMING @ SOFFITS P.T. 1x3 FIRESTOP CONT. 5/8" GYP BOARD OVER R4.1 FI-FOIL INSULATION -STAPLED TO P.T. 1x2 FURRING @ 24" O/C P.T. 1x4 CONT. I I 1=1 I 1=1 I M I l�� I SEE STRUCTURAL PLANS FOR PILING, GRADE BEAMS, FOUNDATION DETAILS 6--4. A LIED �ES 3/411 1 0-011 1 C,fo 0 L .,..q It R U ;,4 ".4 r 'a > �X4 "WO owRowmaw > -Ir OZ, won �1� AM" 7 'I Job No, 1302011 Ft, 0011105 FIRM-AA003'-1- 801 1 1 I In N 12 4 1/2� GALV METAL DRIP OVER P.T. lx2 ON 2x6 CYPRESS FASCIA w/ (2) 16d TO EACH TRUSS MIN%" STUCCO ON SELF FURRING METAL LATH SOFFIT (SCORED TO LOOK LIKE T&G) 2'-0" OVERHANG (TYP.) L-1 12 4 1/2[ U FASCIA DETAIL -1 �11?'= f'O" 00 — REWSIONS BY DATE - qr- A permit sets GS Iq 5.2018 CN tS It § F. Ira Ar,% T34 WOW Job No. 1802011 ky -JAN ff, FL-Wlffli FIRM AAW1179 I" 15 A802 CASING BY INTERIOR 2X6 P.T. BUCK W/ 1/4" DIA. x 00 REMIONS BY DATE permft sets GS 10.5.2018 OR OWNER 1-3/4" EMBED. @ 12" O.C., 6" E.E. WOOD CASING, BY OWNER 1X6 P.T. NAILER PROVIDE 2-1/4" MASONRY EDGE DISTANCE METAL STUD PARTITION W/ PROVIDE SHIMS AS REQUIRED cq DRYWALL SEE WALL SECTION JAMB EXTENSION AS NEEDED GYPSUM WALLBOARD (SEE WALL TYPES) METAL STUD PARTITION W/ WOODDOOR ui (SEE FLOOR PLAN) V ATTACH DOOR FRAME PER LATEST NOA PRODUCT BLOCKING AS REQ'D GYPSUM WALLBOARD (SEE WALL TYPES) WOOD CASING, PAINT GRADE 6 9 I APPROVALS PROVIDE SHIMS AS DOOR STOP (VERIFY W/ OWNER) IMPACT RATED EXTERIOR REQUIRED PRE -HUNG WOOD DOOR FRAME DOOR (NOT FRENCH) PER WOOD CASING BY OWNER DOOR STOP BEYOND EXTEND LATEST NOA PRODUCT WATERPROOFING: APPROVAL PRE -HUNG WOOD DOOR FINISH FLOOR VARIES BY STONE OR BRICK FRAME ROOM THRESHOLD WOOD DOOR BLOCKING AS REQ'D CONCRETE FLOOR SLAB VULKEM SEALANT ON (SEE FLOOR PLAN) NOTES: PRE -HUNG WOOD (SEE FOUNDATION PLAN) BACK SIDE & FRONT F SOU INERIFY wl OWNER IF SOUND ND DOOR FRAME WATERPROOFING INSIDE & OFBUCK NOTES: QU INSULATION WILL BE REQUIRED. FACE OF OPENINGS, SEE SPECS. STUCCO RETURN l.VERIFY W/ OWNER IF SOUND WOODDOOR 2. VERIFY HINGE SIDE W/ FLOOR PLAN. (SEE DOOR SCHEDULE) NOTES: INSULATION WILL BE REQUIRED. STUCCO W/ 2. VERIFY HINGE SIDE FLOOR PLAN. l.VERIFY W/ OWNER IF SOUND SMOOTH FINISH W/ INSULATION WILL BE REQUIRED. 2. VERIFY HINGE SIDE W/ FLOOR PLAN. FILLED CELL OR It 0 POURED COL., SEE STRUCT. *CAULK AS REQUIRED lY2"=l'-0" *CAULK AS REQUIRED lY2"=l'-O" �CAULK AS REQUIRED lY2.'=V-0-' DOOR OUVOWIM0 JAM D[FrAOL 7YP. OMTEROOR DOOR HEAD DOETABIL TVP. ON'TEROOR DOOR JAMB DE7ADL 7YOP. ONTERdOR [DOOR THRESHOLD DIEVABIL NOTES: 8" 1. CAULKING, SEALANT, ADHESIVE, STUCCO W/ PRECAST LINTEL OR POURED BEAM INUIUAI 1=6 6KINI 1,UA I CMU WALL OVER PRECAST PLASTER W/ SMOOTH LINTEL OR POURED CONC.— FINISH BEAM, SEE STRUCT. STUCCO W/ PRECAST LINTEL OR POURED BEAM r PRECAST LINTEL OR POURED BEAM OR GASKET SEALS WINDOW FRAMING SE UCTURAL OVERLAP AND WALL JOINTS TO FORM AIR BARRIER. SMOOTH FINISH DW DWG's) (SEE STRUCTURAL DWG'S) (SEE STRUCTURAL DWG'sl IS 1--ittl 4 2X6 P.T. BUCK W/ Y4" SMOOTH FINISH 2. THESE PRINCIPLES ARE DRYWALL SEE DR' WA WALL SECTIONS t3y4 TAPCONS W/ WASHERS 1%" STUCCO w/ WATERPROOFING INSIDE & -z ALSO APPLICABLE TO DOOR WATERPROOFING INSIDE & SMOOTH FINISH -- ------------- �� I - 0 EMBED @ 8" O.C. MAX, 2" FACE OF OPENINGS, SEE 11 4 D RYWALL SEE fDF WEATHERPROOFING. LMOISTUR FACE OF OPENINGS, SEE M a 0 , s FROM CORNER SPECS. a 0 z WALL SECTIONS AR RIER z z w ell z OVERLAPPED DIRECT SPECS. lX6 P.T. NAILER 1 X6 STONE SURROUND IF At u_ DRYWALL SEE MOISTURE AWAY'FRQM STRUCTURE/ FRAMIN6.� 3Y4' APPLICABLE �zo w w r �`IX6 P.T. NAILER WATERPROOFING INSIDE & FACE OF OPENINGS z 0 W WALL SECTIONS W LL VULKEM SEALANT ON I SEE �, a- BACK SIDE & FRONT CASING BY INTERIOR OR OWNER �NN SPECS. wW. 4 _ly w lX6 P.T. NAILER 311� �6 OFBUCK CASING BY INTERIOR OR OWNER CASING BY INTERIOR OR '�—HEAD CASING/ TRIM JAMB EXTENSION AS OWNER NEEDED CORNERBEAD STANDARD 2" TRACK, 2X4 P.T. BUCK W/ Y4" TAPCONS 1)/4" EMBED 8" O.C. MAX, 2" JAMB EXTENSION AS NEEDED STONE SURROUND & 2X6 P.T. BUCK W/ 1/4" TORSION SPRING STONE SURROUND & @ FROM CORNER 9 �,6 RETURN OTIONAL ELEVATIONS) DIA. x 1-3/4" EMBED. @ 12- O.C., 6" E.E. DRIP KERF IN OPERATED O.H. STUCCO RETURN GARAGE DOOR. RETURN, SEE ELEVATIONS IMPACT RATED FRENCH STONE SURROUND & 2X6 RIPPED P.T. BUCK W/ 1/4" DIA. x 1-3/4" EMBED. @ 12" O.C., t0lk (SEE PROVIDE 2-1/4" 6"E.E. MASONRYEDGE WATERPROOFING INSIDE & STEEL INSULATED IMPACT VULKEM SEALANT ON DOOR INSTALL PER PRODUCT APPROVAL RETURN OPTIONAL SEE ELEVATIONS) PROVIDE 2-1/4" MASONRY WINDOW UNIT DISTANCE FACE OF OPENINGS, SEE SPECS. RATED OVERHEAD DOOR w/ BACK SIDE & FRONT OF BUCK EDGE DISTANCE IMPACT RATED SLIDING WOOD VENEER INSTALL PER FOLDED OR NOTE: DOOR INSTALL PER PRODUCT APPROVAL NOTE: VULKEM SEALANT ON SOLDERED SILL lx BUCKS MAY BE USED IN LIEU OF 2x BUCKS PRODUCT APPROVAL WD. MOULD OVER lx BUCKS MAY BE USED IN LIEU OF 2x BUCKS BACK SIDE & FF ( NT to OFBUCK IMPACT RATED FRENCH DOOR INSTALL PER FLASHING SILL (SLOPED TOP) USE P.T. lX4'S W/ lY2" COIL NAILS @ 8" O/C, THE WINDOW/DOOR IS THEN TAPCONNED THRU THE I X6 SMOOTH USE P.T. lx4'S wl lY2"COIL NAILS @ 8" O/C, THE WINDOW/DOOR IS THEN TAPCONNED THRU THE PRODUCTAPPROVAL JAMB CASING/ TRIM CEDAR BD. OVER OVERHANGS APRON +I- V BUCK TO THE CONCRETE STRUCTURE PER ITS Y4"=V-0" 1X PT. FURRING lY2"=l'-0" *CAULK AS REQUIRED BUCK TO THE CONCRETE STRUCTURE PER ITS lY2"=l'-0" 'CAULK AS REQUIRED ly2"=l.-0" RESPECTIVE NOA REQUIREMENT. RESPECTIVE NOA REQUIREMENT. MRHOOM MITIERPRODIFOH(a SLOMHO QLASS DOOR HE&D DET&L 10 GARME DOOR NE&D DE7AL L 'TWOCAL WHOOM HEAD DOE7&OL TYMCAL FREHCH DOOR HEAD DETAOL ACCEPTABLE WATERPROOFING 2X6 P.T. BUCK W/ 1/4" DIA. x 2X4 P.T BUC_KW/ 1/4" DIA. X 1-3/4' EMBED. @ 12" O.C., 6- E.E. INDICATES SKIM COAT PLASTER W/ SMOOTH FINISH CASING BY INTERIOR 1-3/4" EMBED. @ 12" O.C., 6" E.E. 1. THOROSEAL MIXED W/ ACRYL 60 WATERPROOFING MEMBRANE AROUND CASING BY INTERIOR OR OWNER PROVIDE 2-1/4" MASONRY EDGE DISTANCE 2X6 P.T. BUCK W1 Y4"TAPCONS W/ WASHERS lY4" OR OWNER PROVIDE 2-1/4" MASONRY EDGE DISTANCE CASING BY INTERIOR OR OWNER 2X P.T. BUCK W/ 1/4" DIA. x 1-3/4" EMBED. @ 12" O.C., 6" E.E. 0 PERIMETER OF ALL WINDOW OPENINGS. EXTEND 9" MIN. AROUND PERIMETER FACE EMBED @ 8" O.C. MAX, 2- FROM CORNER lX6 P.T. NAILER 1X6 P.T. NAILER JAMB EXTENSION AS NEEDED DRYWALL SEE JAMB EXTENSION AS NEEDED lX6 P.T. NAILER PROVIDE 2-1/4" MASONRY EDGE DISTANCE u 2. VULKEM 35ONF R MEMBRANE, 25 WET MILS MINIMUM INSIDE OPENING & 10 WET MILS W/ AGGREGATE FOR STUCCO FINISH. EXTEND 12" MINIMUM AROUND DRYWALL SEE IMPACT RATED SLIDING RECESS IN CONCRETE WALL SECTIONS 7 INTERIOR SILL, SEE BY INTERIOR DRYWALL SEE (D PERIMETER FACE. WALL SECTION V DOOR INSTALL PER OR OWNER WALL SECTIONS JAMB EXTENSION AS PRODUCT APPROVAL STEEL INSULATED IMPACT RATED IMPACT RATED WINDOW NEEDED VULKEM SEALANT ON OVERHEAD DOOR w/ WOOD VENEER R U T IMPACT RATED FRENCH DOOR BACK SIDE & FRONT INSTALL PER PRODUCT APPROVAL APPROVAL INSTALL PER PRODUCT OFBUCK �X' VULKEM SEALANT ON APPROVAL WD. MOULD OVER lX6 SMOOTH CEDAR IT, WA—TZERFPRQOFI G BACK SIDE & FRONT EXtEND VULKEM SEALANT ON j:fo 0 XTEND BD. OVER IX PT. FURRING I OF BUCK �IATERPRIQOFING BACK SIDE & FRONT RPROOFING STONE OR BRICK P, -EXTERIOR STONE SILL OF BUCK Xv THRESHOLD WATERPROOFING INSIDE & WATERPROOFING MEMBRANE AROUND STONE SURROUND & U11A STONE OR BRICK 9 u 4 04 R FACE OF OPENINGS, SEE OPENINGS, SEE SPECS. RETURN OPTIONAL THRESHOLD 0 SPECS. STUCCO W/ (SEE ELEVATIONS) STONE SURROUND & :44 m! STUCCO W/ STONE SURROUND & SMOOTH FINISH WATERPROOFING INSIDE & FACE OF OPENINGS, STUCCO w/ RETURN OPTIONAL Q) SMOOTH FINISH RETURN OPTIONAL STUCCO W/ SEE OR SPECS. SMOOTH FINISH (SEE ELEVATIONS) �>. rl 14:1 (SEE ELEVATIONS) SMOOTH FINISH CORNER BEAD FILLED CELL FILLED CELL OR POURED COL., SEE FILLED CELL OR WATERPROOFING INSIDE & POURED COL., SEE NOTE: FILLED CELL OR STONESURROUND STRUCT. NOTE: FACE OF OPENINGS, SEE POURED COL., SEE STRUCT. lx BUCKS MAY BE USED IN LIEU OF 2x BUCKS POURED COL. AT IF APPLICABLE, SEE ELEVATIONS lx BUCKS MAY BE USED IN LIEU OF 2x BUCKS STRUCT. SPECS. USE P.T. lx4'S W/ 1Y2" COIL NAILS @ 8"O/C, THE CMU WALL, SEE USE P.T. lx4'S W/ 1)/2" COIL NAILS @ 8" O/C, THE LK WINDOW/DOOR IS THEN TAPCONNED THRU THE STRUCT. WINDOW/DOOR IS THEN TAPCONNED THRU THE *CAULK AS REQUIRED BUCK TO THE CONCRETE STRUCTURE PER ITS lY2"=l'-0" *CAULK AS REQUIRED lY2"=l'-O" 'CAULK AS REQUIRED BUCK TO THE CONCRETE STRUCTURE PER ITS lY2"=l'-O" *CAULK AS REQUIRED ly2'.=l'-O" 7W RESPECTIVE NOA REQUIREMENT. RESPECTIVE NOA REQUIREMENT. z WAIRERPROOM(a SPECS SUDOH(a QLASS [DOOR J&HB DEUAL p (31MOIE NO METAL DOOR JA 'TVPOC&L �WIHDWW JAMB DE7L%OL irupocAL FRIEMCH DOOR JAMB DIFTAUL B im 1. ALL WINDOWS & EXTERIOR DOORS SHALL BE DESIGNED & INSTALLED TO WITHSTAND STONE OR STUCCO APPLICABLE WIND LOADS AS REQUIRED BY FLORIDA BUILDING CODE 2017 AND ANY EXTENSION IAMB —\ — OTHER APPLICABLE CODES. SLIDING GLASS IF APPLICABLE 2. GENERAL CONTRACTOR TO VERIFY MASONRY OPENINGS REQUIRED WITH WINDOW & ALUMINUM BI-PARTING DOOR SILL RISER (SEE MFG. SPEC's) MOULD & 1X6 SMOOTH CEDAR BD. TILE OR EPDXY FLOOR (SEE ELEVS) IMPACT RATED FRENCH DOOR INSTALL PER DOORJAMB EXTENSION Job No. 1802011 DOOR SPECIFICATIONS. SLIDING GLASS DOOR HVERIFY w/ OWNER) VULKEM SEALANT ON PRODUCT APPROVAL (SEE DOOR SCHEDULE) *ADJUST FINISH FLOOR AS 77 BACK SIDE & FRONT STONE OR STUCCO FRENCH DOOR & 3. ALL EXTERIOR WINDOW & DOOR GLAZING TO BE TINTED TO REDUCE SOLAR HEAT NECESSARY TO FINISH OUT FLUSH CASTSTONE OFBUCK 2X4 P.T. BUCK W/ 1/4" DIA. EXTENSION JAMB IF ALUM.THRESHOLD, ii GAIN IF REQUIRED BY ENERGY CALCULATIONS. ATTACHMENT PER W/ SLIDING GLASS DOOR SILL SURROUND, BEYOND x 1-3/4" EMBED. @ 12" O.C., APPLICABLE (SEE ELEVS) 7 INSTALL PER L MFG.SPEC's RISER WINDOW SILL 6" E.E. PRODUCT APPROVAL 4. ALL WINDOWS & EXTERIOR DOORS TO HAVE A SOLAR HEAT GAIN COEFFICIENT (SHOPI EXTERIOR LANAI STUCCO RETRUN (SEE ELEV'S) PROVIDE 2-1/4" MASONRY IX P T BUCK W/ Y4" AS INDICATED IN THE ENERGY CALCULATIONS. FLOOR FINISH EDGE DISTANCE TAPC'O'NS 1YFEMBED 5. G.C. SHALL SUBMIT ALL REQUIRED ENGINEERED SHOP DRAWINGS AND DOCUMENTED CONCRETE FLOOR SLAB SLOPE DRIVEWAY PAVERS (VERIFY W/ lz: WATERPROOFING INSIDE & SILL &APRON BY INTERIOR VULKEM TRAFFIC COATING @ 12" O.C., 2"MAX WINDOW AND DOOR TESTING SHALL BE SUBMITTED FOR REVIEW AND APPROVAL BY THE OWNER) SL PEEZ FACE OF OPENINGS, SEE OR OWNER 8 FROM CORNERS. ARCHITECT. SPECS. lu z STONE OR BRICK PAVERS, RISERS & FINISHED FLOOR, BY S 6. SEE FLOOR PLANS FOR WINDOW & DOOR LOCATIONS. I X6 P.T. NAILER THRESHOLD (TYP.) OWNER FL-0011105 FIRM-AA001379 7. ALL WINDOWS & DOORS SHALL BE MANUFACTURED TO PROVIDE ALL JOINING , DRYWALL SEE WALL w MATERIALS AND NECESSARY INSTALLATION ACCESSORIES AS REQUIRED PER WINDOW I STUCCO W/ SECTIONS OR DOOR DESIGN TO MEET CODE FOR LOADS. INDICATES CONCRETE SLAB (SEE STRUCTURAL DWG's) SMOOTH FINISH W %"RECESS CONCRETE SLAB TYP. 8. SEE BUILDING ELEVATIONS, DOOR & WINDOW SCHEDULES FOR HEAD HEIGHTS, POURED CONCRETE SILL (SEE STRUCTURAL DWG's) z w < V) _i a- 1 " RECESS @ DOOR MUNTIN BARS, AND OVERALL CONFIGURATION. INDICATES STEEL INSULATED DOOR wl WOOD VENEER A'3Y2. 41/2" THRESHOLD (SEE DOOR SCHEDULE) NOTE: 9. SHOWER WINDOWS TO HAVE WINDOW TREATMENT FOR PRIVACY, CONCRETE FLOOR lx BUCKS MAY BE USED IN LIEU OF 2x BUCKS 8" SLAB USE P.T. lx4'S w/ IY2" COIL NAILS @ 8" O/C, THE WINDOW/DOOR IS THEN TAPCONNED THRU THE *CAULK AS REQUIRED lY2"=l'-0" *CAULK AS REQUIRED lY2"=l'-0" *CAULK AS REQUIRED BUCK TO THE CONCRETE STRUCTURE PER ITS lY2"=l'-O" *CAULK AS REQUIRED lY2"=l.-O" 901 RESPECTIVE NOA REQUIREMENT. [EKYEROOR WHOOM A DOOR OEMENAL HOTES a SLOOM OUSS DOOR SLL [M&L H I QUIME DOOR OLL DEV&L OCAL Y�N_DDM BOLL DEVA�L E 'fMC&L FREHCH DOOR SADDLE DIEr6ML ! 1 I I I � 1 GUY GRAY SPACE SAVER WITH 4" DEEP BOX FOR METAL STUD WALL WATER HAMMER ARREST, HW & CW HOSE CONNE( WNACUUM BREAKERS (WATTS OR EQUAL) 2017 FLORIDA BUILDING CODE -RESIDENTIAL 1/2" HW & CWPIPING PER FBC 2017 P405.3.1: "A WATER CLOSET, URINAL, LAVATORY OR BIDET SHALL NOTBE 2" DIA, WASTE FINISHED WAL SET CLOSER THAN 15 INCHES FROM ITS CENTER TO ANY SIDE FINISHED FLOOR WALL, PARTITION, VANITY OR OTHER OBSTRUCTION, OR CLOSER THAN 30 INCHES CENTER -TO- CENTER BETWEEN ADJACENT FIXTURES. THERE SHALL BE NOT LESS THAN A 21-INCH CLEARANCE IN FRONT OF THE WATER CLOSET, URINAL, LAVATORY OR BIDET TO ANY WALL, FIXTURE OR DOOR. 3/8"=110" WASH�Na MACHWE CONNECnON BETML TYMCAL PLUMIMM FIKTURE CLEARANCE J, J BEAD — VERTICAL WALL PAN FLASHING NAILED TO WALL WITH 300, 1" RETURN. �� z ROOF ABUMNO CHU WALL z . C.M.U. WALL - REFER TO DRAWINGS FOR DETAILS. 5/8" STUCCO EXTEND ELASTOFLEX SAP UP WALL BEHIND COUNTER -FLASHING MIN. 4". PROVIDE TEST TEE 1. WATER HEATER: SEE MANUFACTURER'S SPECS FOR INSTALLATION DETAILS. 2. THERMAL EXPANSION PROVISIONS REQUIRED BY USE OF THERMAL EXPANSION TANK OR APPROVED DEVICE. 3. COORDINATE WITH PLUMBING PLANS T&P TO GR( WITH 2" AIR RELIEF VAL: 2"AIR GP 40T TO SCALE Mu I vvm I COLD WATER SUPPLY SUPPLY WATTS BRVT PRESSURE RELIEF VALVE HEAT PRESSURE TRAPS RELIEF DRAIN HOT WATER WITH 2" AIR GAP RETURN '�if recirc) CHECK )UD VALVE G A co — REVISIONS T"""" 0 Apermit sets BY DATE GS 1015.2018 ta MAX. SOUND INSULATION ^I 'q JU Z LU z < < IF REQUIRED OWNER) v 0 L6 W Lu U) U) (VERIFY wit 0- EL c; 5/8" DRYWALL EA. SIDE '-SEE NOTE" PROVIDE LEVEL a ruvion UlY AILL k^v INTERIOR PAINTED DRYWALL SURFACES METAL FRAMING (25ga) @ 16" D.C. MAX. -SOUND INSULATION, IF REQUIRED (VERIFY w/ OWNER) METAL SILL CHANNEL OVER PLATE NOTE: .H. **USE WATER RESISTENT GREEN BID. FOR ALL PAINTED, NON -TILED WALLS NOT IN M '\ 7'�' S. O.V. 0 nU AC 0 U nnRAO 0 VI7i`LJI=KI(Z nRCEMENTBACKER 12_ ELECTMC WATER HEATER DETML 20 ga. METAL FRAMING @ 16" O.C. MAX. OR AMRSTRONG DRYWALL GRID SYSTEM (SUSPENDED FROM STRUCTURE 4'OC MAX.) r___�) WITH SCREWED COUNTER- COLUMN OR PA�LTITION SUNK ASS PLASTIC PLUG: AS SHOWN ON I OOR PLAN TAPEREDiTHREAD WITH CLEANOUT FACE SHALL TFE JOINT COMPOUND BE WITHIN 4" OF WALL SURFACE. PROVIDE WHERE CLEANOUT TEE PIPE EXTENSION IF REQUIRED, IS CONCEALED IN A CHASE OR PARTITION, N PROVIDE A ROUND 18 GAUGE STAINLESS STEEL _E D COVER WITH BEVELED EDGES AND FLATHEAD MACHINE SCREW, CONCR!ET:E�� FLOOR SLAB NOTE: PROVIDEWCO WHERE SHOWN ON PLAN, AND ON SANITARY WASTE BRANCHES NOT SERVED WITH A FLOOR OLEANOUT� LOCATE ABOVE FIXTURE FLOOD RIM WITHIN 4'OF FLOOR. CONSULT LOCAL CODES FOR OTHER WCO REQUIREMENTS 1 1/2"=l '-0" H 14 1 WALL CLEA N OUT DE-ML CD NOT TO SCALE CF�L�X(a ZE74�L 4 4 CMU OR CAST IN Fw 4 1 , 1 4 PLACE WALL 4 4 4 4' 4 4 4 T_ P.T. 2x4 x 8" LONG w/ CONCRETE < (2) %4" x 3" TAPCONS FASTENERES AS TO CONCRETE REQUIRED P,T. 2x4 STRONG BACK BRACE @ 48" O/C MAX 48" max P.T. 2X4 STRONGBACK P.T. 2x4 @PERIM wit @ 16" OIC @ 48" O/C MAX Y4" x 1 Y4" EMBED TAPCONS 0 0 CLIP ANGLE, NO LESS THAN METAL JOIST DEPTH MINUS 1/2" (ATTACH CLIP P.T. 2x4'S @ 24" /C Ix T&G CLG NAILED TO 2x4S & TRACK TO CONCRETE wit EXP. , 1 ANCHOR BOLTS, OR TAPCONS) Fk�TERgcn DROPPED CFEUNQ DIETML NOTE: PROVIDE SOLID BLOCKING & BRIDGING AS REQUIRED C[E�LW(3 jawr 177ACHEMEN'T DlMrUL DIRECT CON IAGI Wi vvmltK U MI � I BID. (DUROCK) FOR ALL TILED WALLS IN DIRECT CONTACT wit WATER, SUCH AS SHOWERS & TUB SURROUNDS" NOT TO SCALE 1 1/2"=1'_0" T T TYMCAL W7EMOR FARTJTJOK WALL (NON-SEAMMM 5/8" STUCCO FINISH (VERIFY FINISH & COLOR) 7 _tw�d CD 0 U-1 F_ Q Z LU < LU cj� CD 0 z F- =� UJ 5/8" GYP. BID. FASTENED 6" D.C.@ PERIMETER & 8" O.C. BA NCE NOIE: **USE WATER RESISTENT GREEN ED. FOR ALL PAINTED, NON-TiLED WALLS NOT IN DIRECT CONTACT wit WATER SUCH AS BATHROOMS & KITCHENS, USE CEMENT BACKER BD. (DUROCK) FOR ALL TILED WALLS IN DIRECT CONTACT w/ WATER, SUCH 1 1/2"=l'-0" AS SHOWERS & TUB SURROUNDS" 1 1/2—l'-0- 7 TV MCAL EKTEMOR CHU WALL 3 4 INTERIOR 4 SIDE 518" DRYWALL (USE MOLD RESISTANT DRYWALL ON ALL EXTERIOR PERIMETER EXTERIOR WALLS), FURRING & INSULATION PER SIDE TYPICAL WALL SECTIONS CMU WALL OR CAST IN PLACE CONCRETE (SEE STRUCTURAL DWG's) METAL JOIST TRACK INTERIOR SPACE (UNFINISHED) METAL JOIST CMU WALL OR CAST IN PLACE CONCRETE INTERIOR (SEE STRUCTURAL SPACE DWG's) (FINISHED) 5/8" DRYWALL ON MIN. 7/8" FURRING CHANNELS @ 16" D.C. MAX NOTE: **USE WATER RESISTENT GREEN BD, FOR ALL PAINTED, NON -TILED WALLS NOT IN DIRECT CONTACT wit WATER SUCH AS BATHROOMS & KITCHENS, OR CEMENT BACKER ED. (DUROCK) FOR ALL TILED WALLS IN DIRECT CONTACT wl WATER, SUCH AS 1 1/2"=l'-O" SHOWERS & TUB SURROUNDS" 1 1/2"= 1 1-01, 1 6 TV MCAL WTEMOIR CHU WALL 12 J VENT W/ ----,—ROOF TRUSSES @ 24" O/C PERFORATED CAP 0 z C.0 PLUG 3" ABOVE TOP OF PRIMARY 0 W w Q. (SCREWED) DRAIN PAN AHU a 0 IN W LU PREFAB ATTIC ACCESS > TI ;E SCUTTLE FRAME ATTACH UNION PER MANUF SPECS z O_ CONNECTIO TSP -1 b LLI ELBOW n z TSP +1" .... .. IT' MIN ��177OF A. SLOPE DRAIN LINE TO CONDENSATE RECEPTOR (MIN. 1/8" PER FOOT) LPRE-MANUF SCUTTLE DOOR OR B DRAIN LINE SHALL BE COPPER TYPE"VANDINSULATED 518" GYP BOARD SCREWED TO G TSP = FAN TOTAL STATIC PRESSURE. MIN 1/2" CDX PLYWOOD PANEL —DECORATIVE TRIM IS PART SCUTTLE FRAME EXTERIOR FINISH (SEE ELEVATIONS) I GYP. ED. FINISH (SEE WALL TYPE 8 FLOOR PLANS) IU WALL OR CAST IN PLACE NCRETE :E STRUCTURAL DWG'S) kLL INSULATION :E TYPICAL WALL SECTIONS) IRRING & GYPSUM BOARD :R TYPICAL WALL SECTIONS 3" GYP. BID. FINISH EE WALL TYPE & FLOOR PLANS) ETAL STUD FRAMING EE WALL TYPE & FLOOR PLANS) )UND INSULATION kz:,EE WALL TYPE 8, FLUVM 1-1-MI10) Cl <� 1002 4-> 0 �Z4 L :> Oil r j U s r 9 'MOM Job No. 1802011 TYPICAL DETAILS A902 CEILING NOT TO SCALE NOT TO SCALE 1 1/2"=V-0" CONDENSATE P=TRAP DIETA�L 9 TfmALA'rncA0CE8SCEML L5 awo WALL TO CONCRETE WALL DEMML ELECTRI�AL RISER DIAGRAM ELECTRICAL I METER & MAIN DISCONNECT 0.1� 150AMP B = METER 150AMP A.I.C. A.I.C. 10,000 10,000 UNDERGROUND TO FP&L TIE-IN LOCATION (1) #2 CU TO 518" GROUNDING ROD & TO FOOTER STEAL (1) #2 CU. GND. WIRE TO H20 150A 150A PANEL PANEL B A 10 CKTS 40 CKTS M.L.O. M.L.O. (3) #2/0 CU & (1) #6 IN 2" C. ELECTRICAL LEGEND PHONEJACK ELECTRIC METER WALL MOUNTED FIXTURE DOUBLE CAT 5, CABLE ELECTRIC PANEL liv] VIDEO OUTLET CEILING MOUNTED FIXTURE DISCONNECT & CENTRAL VAC. HOSE OUTLET 220 VOLT RECEPTACLE WALL MOUNTED J-BOX 4) EXHAUSTFAN SINGLE OUTLET 0 SMOKE DETECTOR 4)c DUPLEX OUTLET CEILING MOUNTED J-BOX THERMOSTAT DUPLEX OUTLET - HALF SWITCHED L SPRINKLERTIMER GF G.F.C.I. PROTECTED OUTLET -4PC"- PULL CORD FIXTURE 0 INTERCOM VIPGF WEATHER PROOF GFCI OUTLET Fk-pl KEYPAD DUPLEX FLOOR OUTLET RECESSED ADJUSTABLE FIXTURE WALL SWITCH 13 RECESSED LIGHT FIXTURE MOTION DETECTOR -b-�-3 3-WAY WALL SWITCH VP [3 VAPOR PROOF RECESSED FIXTURE -69-4 4-WAY WALL SWITCH U71 FLOURESCENT LIGHT FIXTURE +�)-D DIMMER WALL SWITCH CEILING FAN -bg-PB PUSH BUTTON SWITCH A N FLOOOISECURITY LIGHTS UNDER CABINET FIXTURE 2) #6, 1 #6 NEUTRAL, 1) #10 GND IN 1" C. 60AMP M.L.O. PNL AMPS1 VOLTAGE :CKTS�SE A 150 120/240 42 1 3 1 1 CIR# WIRE POLEJAMPS SERVING WIN I CIR#IWIRE LE POLEJAMPS1 SERVING WIN 1 6 2 1 50 AHLI #1 5.0 2 6 2 50 ACCU #1 3 4 5 10 2 30 1 WATER HEATER 4.5 6 6 - 2 2 F2 50 OVENS 5.4 1 7 a 9 6 2 50 ACCU#3 - 10 1 0 6 2 2 60 1 AHU #3 10.0 0 0 11 12 1 2 13 12 1 1 20 COOKTOP HOOO 1.5 14 14 12 1 20 GARAGE DR OPENER 5 1.5 is 1 1 20 SMAL APPLIANfE #1 1.5 16 16 12 1 1 20 ATH GFI'S #1 1.5 - 5 17 SPACE - 18 18 ___7 12 1 1 io CEN VAC 1.2 12 19 14 1 1 15 GEN'L LIGHTING 20 14 1 1 21 14 1 15 GEN'L LIGHTING 22 1 1-4 1 15 GEN'L LIGHTING 23 14 1 15 GEN'L LIGHTING 24 14 1 5 GEN'L LIGHTING 25 14 1 15 GEN'LLIGHTING 26 1 14 1 1 15 GEN'L LIGHTING 27 14 1 15 -'&ENL LIGHTING 28 1 14 1 1 15 GEN'L LIGHTING 29 14 1 1 15 WL LIGHTING &E- 30 14 1 15 GEN'L LIGHTING 31 14 1 15 GEN'L LIGHTING 32 14 1 15 GEN'L LIGHTING 33 SPACE 34 SPACE 35 36 37 38 39 40 41 42 42 'A' LOAD @ 65% @ 100% 0 GEN. L-rING (2,509 SF @ 3W/SF) 7.5 PANEL A TOTAL KIN = 3a6 9.8 25,700 W. = 107.1 Amps 240 V. PNL AMPS1 VOLTAGE cKrs _F_P__s Fw-i-RE HA ET ... B 150 120/240 CIR# R Wl�E POLEJAMPS SERVING KW CIR# WIRE POLE AMPSFSERVING KIN 1 6 2 60 AHU#2 10.0 2 10 2 30 ELEVATOR 3.0 3 4 5 6 2 60 ACCU #2 . - 6 12 2 20 DIN & DISP #1 2.2 7 7 8 9 9 6 2 50 __ COOKTOP 5.0 10 - 10 2 30 DRYER 4.5 11 12 13 12 1 20 WASHER 1.2 14 12 1 20 BATH GFI'S #2 1.5 15 12 1 20 RECIRCULATING PUMP 1.2 16 12 1 20 SMALL APPLIANCE #2 1.5 17 12 1 20 KIT REF 1.6 18 -SPACE - 19 14 1 15 GEN'L LIGHTING 20 14 1 15 GEN'L LIGHTING 21 14 ____T_ 1 15 'L LIGHTING GEN- 22 14 1 - 15 GEN'L LIGHTING 23 14 1 1 15 GEN'L LIGHTING - 24 - 14 1 15 1 GEN'L LIGHTING 2 5 S 14 1 1 15 GEN-L LIGHTING 26 14 1 15 GEN'L LIGHTING 27 14 1 1 15 GEN-L LIGHTING 28 14 1 15 GEN'L LIGHTING 29 14 1 1 15 GEN'L LIGHTING 30 14 1 15 GEN'L LIGHTING 31 1 14 1 1 15 GEN'L LIGHTING 32 14 1 15 GEN'L LIGHTING 33 SPACE 34 SPACE 35 36 3 37 38 9 39 40 41 42 PANEL'B'LOAD CALCULATIONS lst 10.0 KW @ 100% 10.0 LARGEST OF: HEATING @ 65% 6.5 COOLING @ 100% REMAININGKWQ40% T7 TOTAL KIN 24.2 GEN. UTING (2,509 SF @ 3WISF) 7.5 PANEL B TOTAL KIN = 39.1 24,200 W. 100.8 Amps 240 V. ELECTRICAL NOTES GENERAL: 1) CONTRACTOR SHALL VERIFY THE LOCATION OF SERVICE AND $HAILL FKUR - 1) PROVIDE GREEN WIRE GROUND TO ALL EXTERIOR FIXTURES AND "J' LOCATE THE METER & PANELS AS REQUIRED. BOXES. 2) ALL WIRE SHALL BE THHN COPPER, UNLESS NOTED OTHERWISE. 2) ELECTRICAL FIXTURES, TRIM AND APPLIANCES SHALL BE UL APPROVED 3) WHERE REQUIRED BY OTHER CODES, SERVICE AND FEEDER AND AS SELECTED BY OWNER. CONDUCTORS SHALL BE COPPER OF EQUAL AMPACITY. 3) ALL LIGHTING FIXTURES AND FANS TO BE SELECTED & LOCATED BY 4) ALL BRANCH CIRCUITS IN RACEWAY OR NON METALLIC SHEATHED CABLE. OWNERIARCHITECT/INTERIOR DESIGNER, UNLESS OTHERWISE NOTED. 5) COORDINATE RACEWAY INSTALLATIONS WITH OTHER TRADES PRIOR TO 4) ARCHITECT TO SET MOUNTING HEIGHTS FOR ALL FIXTURES WHERE CONSTRUCTION. APPLICABLE, UNLESS OTHERWISE NOTED, 6) ROMEX MAY BE USED WHERE CONDUIT IS NOT REQUIRED. 5) FLUORESCENT CLOSET LIGHT FIXTURES SHALL HAVE A MINIMUM 7) BX CABLE MAY BE USED IN LIEU OF RIGID CONDUIT. CLEARANCE OF 6" AWAY FROM CLOTHING. 8) VERIFY ALL CONDUCTORS AND BREAKERS WITH EQUIPMENT 6) PREWIRE FOR GARAGE DOOR OPENER SENSOR. MANUFACTURER SPECIFICATIONS. 7) HIHATS TO BE 4' ROUND 9) PROVIDE DISCONNECT SWITCHES OF SIZE AS REQUIRED BY LOADS. OUTLETS: 10) PROVIDE NON -FUSIBLE GENERAL DUTY SAFETY SWITCHES ATAIC EQUIP. 1) ALL COUNTERTOP RECEPTACLES SHALL BE GFCl OUTLETS. AND AT PUMPS NOT VISIBLE FROM CIRCUIT BREAKER PANEL AND AS PER 2) PROVIDE GFCI BREAKERS FOR ALL BATHROOMS, GARAGE AND EXTERIOR MANUFACTURER RECOMMENDATIONS. OUTLETS AS SHOWN ON PLANS. 11) PROVIDE DISCONNECTS FOR POOL PUMP PER N.E.C. 680. POOL 3) ALL 125 VOLT 15 AND 20 AMP RECEPTACLES TO BE TAMPER RESISTANT CONTRACTOR SHALL PROVIDE ELECTRICAL CONTRACTOR WITH ALL LOADS PER FBCR E3902.12. PRIOR TO INSTALLATION. ELECTRICAL CONTRACTOR TO MAKE ALL 4) PROVIDE PRE -WIRED TELEPHONE & CABLE T.V. OUTLETS AS SHOWN ON CONNECTIONS PER POOL COMPANY DRAWINGS. VERIFY LOCATION OF ALL PLAN. PROVIDE OPTIONAL PRE -WIRED HIGHSPEED DATA OUTLETS AS SHOW POOUSPAEQIUPMENT. 12) ALL 120 VOLT 15 AND 20 AMP CIRCUITS THAT SERVE FAMILY ROOMS, ON PLANS, (IF APPLICABLE) 5) FOR FLOOR RECEPTACLES, PROVIDE A COVER PLATE AND FLUSH WITH DINING ROOMS, LIVING ROOMS, PARLORS, LIBRARIES, DENS, BEDROOMS, FLOOR. VERIFY EXACT LOCATION WITH GCIOWNER. PROVIDE 112"CONDUIT SUNROOMS, REC ROOMS, CLOSETS, HALLWAYS, OR SIMILAR ROOMS TO BE UNDER SLAB FROM WALL. ARC FAULT CIRCUIT PROTECTED PER FBCR E3902.12. SMOKE DETECTORS: 13) WIRES SMALLER THAN #6 SHALL HAVE THHN INSULATION, #6 & LARGER 1) ALL SMOKE DETECTORS TO HAVE BATTERY BACK UP AND SIGNAL SHALL HAVE THWN INSULATION. SIMULTANEOUSLY W/ TEMPORAL SOUND. 2) SMOKE DETECTORS TO BE LOCATED MIN 3�0" FROM: RIA & SUPPLY GRILLS, KITCHENS, BATH ROOMS. 3) SMOKE DETECTORS TO BE COMBINATION TYPE CARBON MONOXIDE ALARM & SMOKE DETECTOR. ELEVATOR NOTES: 1. ELEVATOR SHALL MEET NEC 620 22-23; VERIFY LOCATION AND ELECTRICAL REQUIREMENTS OF ELEVATOR EQUIPMENT WITH MFG SPECS PRIOR TO CONSTRUCTION. 2. IF THERE IS AN ELEVATOR PIT LOCATED BELOW, PROVIDE WITH FLOAT SWITCH SENSOR; LIGHT FIXTURE SHALL NOT BE INSTALLED IN ELEVATOR PIT. 3. PROVIDE A LIGHTING FIXTURE WITH RECEPTACLE OUTLET, CONTROLLED BY A SWITCH LOCATED AT THE PASSAGEWAY OPENING PER FMC 306.31. PNL JAMPS1 VOLTAGE ICKTSIWIRE1 PHASE I P (POOL) 60 120/240 12 1 3 1 1 1 CIR # WIRE I POLE JAMPS SERVING KW CIR# WIRE POLEJAMPS1 SERVING KW 1 8 2 40 POOLPUMP 1.5 2 1 20 1 POOL LIGHTS 0.8 3 4 12 1 20 POOL HEATER IGNITER 0.5 5 SPACE f2l 6 12 1 20 POOL CONTROLLER 0.5 7 8 SPACE 9 10 I 1 12 PANEL'P'LOAD CALCULATIONS Ist 10.0 KW @ 100% 3.3 LARGEST OF: 0.0 HEATING @ 65% (6.5 KIN) COOLING @ 100% (KW) REMAINING KIN (M, 40% TOTAL KW U.�s r`�C]Lr IV I ALINVV� o.. 3,300 W. = 13.8 Amps 240 V. co REMIONS BY DATE T� permit sets GS 103.2018 N Ln �4 -4 Ajift 9 802011 AAN 2 �_ 20% �. . 6k* E 10 1 dgm — row I (ama DR COOKTOP wl OVENS on w i A I I k L z L1 LIBRARY F-7 Li Cofiv, Cl� 10,4"J11, L (VERIFY HT.) 0+60. W/BACKING FOR TV MOU L TOLOWER VERIFV�--j FLOOR4- LOCATIONJ SWITCH GRI:�'A:'r ftoo'm C�,, I ��P 1' 4" ON TO UPPER FL20R SWITCH @ +60' (VERIFY HT v CKING w 2 FO'EV MOUNT ELE VATOR TO POOL %IGHTS I EXTERIOR LIGHTING FIXTURE SCHEDULE I SYMBOL I FIXTURE NAME QUANT BULB WATT & TYPE MOUNTING MOUNTING HEIGHT 0 FLIR 1 FLR 12 FLR I TOTAL Ll H36LVTAT-3011.TBZBB (BRONZE) H36LVTAT-301 1-SNBB (NICKEL) 11 11 5W AMBER LED MR16 CEILING IN CEILING L2 SeaGull 8313901 EN-1 0 WALL SCONCE 3 4 7 9w AMBER LED A19 WALL 6'-W L3 SAGA STEP LIGHT (HORIZ LOUVER) SG-R-1LED-HDL-AML 3 3 (4) 1w AMBER LED PER FIXTURE WALL ABV STEPS (SEE ELEVS) 1_4 1.5 TEKA 20" ARCADE HALF SHIELD (14" @ GARAGE DOOR) 4 2 6 (1) 10W LED WALL 8%6" LB PENTAIR INTELLIBRITE 5G 3 3 INTELLIBRITE LED 26W -TURTLE EDITION CEILING BELOW WATER LINE 'I � f"F v A i 1ST FLOOR ELEC RIC PLAN S ALE: 3/16" = V-011 L8 m L8 NOTE: PER 62B-33.0155(l)(n) ALL WINDOWS AND GLASS DOORS VISIBLE FROM ANY POINT ON THE BEACH MUST BE TINTED TO A TRANSMITTANCE VALUE (LIGHT TRANSMISSION FROM INSIDE TO OUTSIDE) OF 45% OR LESS THROUGH THE USE OF TINTED GLASS OR WINDOW FILM VERIFY FIXTURE FINISHES WITH OWNERIINTERIOR DESIGNER VERIFY FIXTURES WITH DEP SUBMITTAL NON -BREAKAWAY A STRUCTURAL CONCRETE Zj� COLUMN TYP. ELECTRICAL LEGEND ELECTRIC METER WALL MOUNTED FIXTURE PHONEJACK DOUBLE CAT 5e CABLE ELECTRIC PANEL FRI DISCONNECT -0- CEILING MOUNTED FIXTURE VIDEOOUTLET S CENTRAL VAC. HOSE OUTLET 4@1 220 VOLT RECEPTACLE -0- WALL MOUNTED J-BOX 6) EXHAUST FAN SINGLE OUTLET DUPLEX OUTLET 0 SMOKE DETECTOR CEILING MOUNTED J-BOX THERMOSTAT 4a. DUPLEX OUTLET - HALF SWITCHED GF G.F.C.I. PROTECTED OUTLET L 4PC'I- PULL CORD FIXTURE SPRINKLERTIMER INTERCOM WPGF WEATHER PROOF GFCI OUTLET 191 DUPLEX FLOOR OUTLET RECESSED ADJUSTABLE FIXTURE KEYPAD _61�_ WALL SWITCH RECESSED LIGHT FIXTURE MOTION DETECTOR -&)-3 3-WAY WALL SWITCH VP[3 VAPOR PROOF RECESSED FIXTURE -u�-4 4-WAY WALL SWITCH I FLOURESCENT LIGHT FIXTURE -6q-D DIMMER WALL SWITCH CEILING FAN -69-PB PUSH BUTTON SWITCH FLOOD/SECURITY LIGHTS UNDER CABINET FIXTURE 2 MMAMMININ 9MMMEMMERHEMMEMEMEJ qp qp BONLTS S'T.'ORAGEII ROOM NOTE: ELECTRIC, MECHANICAL, & PLUMBING SYSTEM COMPONENTS AT THIS LEVEL ARE NOT TO BE MOUNTED ON OR PENETRATE THROUGH WALLS THAT ARE DESIGNED TO BREAK AWAY UNDER AHU 1 WALLLOUVER 1-- BX6 �400 CFM FAN CONTROILED BY GARAGE CO SENSOR MOUNT FIXTURES TO COLUMNS -MOUNT VAC & RECEPTACLE TO COLUMN HARDWIRE W/ SWITCH POO EQUIP MOUNT FIXTURE TO C MN 0 LU GARAGE LEVEL ELECTRIC PLAN SCALE: 3/16" = V-0" MOUNT FIXTURE TO BEAMISLAB ABV NOT BREAKAWAY WALL m REMSIONS BY DATE 'Irm ;.�. Apemit sets GS 10.5.2018 & 1 st Bldg ColleltS GS 3.12.2019 2 pu f 0 4 u r .4-3, u '.t4 �ob No 180M! 1 FL-0011105 FIRM-AM0379 E201 I � EXTERIOR LIGHTING FIXTURE SCHEDULE I S �MBOL FIXTURE NAME QUANTITY BULBWATT&TYPE MOUNTING MOUNTING HEIGHT FLR 11 FLR 2 FLR TOTAL Ll H36LV-FAT-301 1 -TBZBB (BRONZE) H36LVTAT-3011-SNBB (NICKEL) 11 11 5w AMBER LED MR1 6 CEILING IN CEILING u SeaGull 8313901EN-10 WALL SCONCE 3 4 7 9w AMBER LED A19 WALL V-6- LZ SAGA STEP LIGHT (HORIZ LOUVER) SG-R-lLED-HOL-AML 3 3 I (4) 1w AMBER LED PER FIXTURE I WALL ABV STEPS (SEE ELEVS) L4 I LEE TEKA 20"ARCADE HALF SHIELD (14" @ GARAGE DOOR) 4 2 6 (1) 10w LED WALL 8'.6" LE PENTAIR INTELLIBRITE 5G 3 3 INTELLIBRITE LED 26W -TURTLE EDITION CEILING BELOW WATER LINE NOTE: PER 62B-33.0165(l)(n) ALL WINDOWS AND GLASS DOORS VISIBLE FROM ANY POINT ON THE BEACH MUST BE TINTED TO A TRANSMITTANCE VALUE (LIGHT TRANSMISSION FROM INSIDE TO OUTSIDE) OF 45% OR LESS THROUGH THE USE OF TINTED GLASS OR WINDOW FILM VERIFY FIXTURE FINISHES WITH OWNER/INTERIOR DESIGNER VERIFY FIXTURES WITH DEP SUBMITTAL F-�:: F ELECTRICAL LEGEND PHONEJACK ELECTRIC METER WALL MOUNTED FIXTURE DOUBLE CAT 5e CABLE ELECTRIC PANEL DISCONNECT CEILING MOUNTED FIXTURE VIDEO OUTLET S CENTRAL VAC. HOSE OUTLET 220 VOLT RECEPTACLE —0— WALL MOUNTED J-BOX 6) EXHAUSTFAN SINGLE OUTLET 0 SMOKE DETECTOR 3@r DUPLEX OUTLET —0— CEILING MOUNTED J-BOX THERMOSTAT DUPLEX OUTLET - HALF SWITCHED -L SPRINKLERTIMER GIF G.F.C.I. PROTECTED OUTLET -4PC)-- PULL CORD FIXTURE (D INTERCOM WPGF 4@1C WEATHER PROOF GFCI OUTLET =1 PEN DUPLEX FLOOR OUTLET RECESSED ADJUSTABLE FIXTURE R KEYPAD -bl�- WALL SWITCH RECESSED LIGHT FIXTURE MOTION DETECTOR -61�-3 3-WAY WALL SWITCH VP VAPOR PROOF RECESSED FIXTURE -E,9-4 4-WAY WALL SWITCH FLOURESCENT LIGHT FIXTURE -69- D DIMMER WALL SWITCH CEILING FAN -6+PB PUSH BUTTON SWITCH FLOOD/SECURITY LIGHTS UNDER CABINET FIXTURE @ +601' W/ BACKING ......... M "M,m IMIM C41 vp, �@+60"w/ BACKING FOR TV MOUNT K"DR( )0M 0 Ell @ +60' W/ BACKING FORTVMOUNT7 2ND FLOOR ELECTRIC PLAN SCALE: 3/16" = V-0" cNi T� vi i REVISI ONS BY DATE permit sets GS 10.5.2018 1st Bldg Comments GS 3.12.2019 0 C u con r y LL 2M= I Job No, 1802011 1 N MAR 13 2019 FL-0011105 FIRM - 1"00.3379 E202 GAS )!"�GE LEVEL Dt 03 R SCHEDULE MARK SIZE TYPE NOTES WD, HGT 1 3'-0" 8'-0' FRENCH 2 16'-0" 8'-Oo OVERHEAD-GWGE DRi 3 2'-6" 81-0- FRENCH 4 3'-0' 7'-0' EXT SWING PVC JAMB 5 3'-0" 7'-0' E)Cr SWING Pvc, AB 6 2'-6" 8'-0* FRENCH 7 2'-8" 8'-0' INT SWING (SC) I MIN 1 3/f.-I" 14, SELF CU)SER 8 2'-B' 8'-0' INT SWING (SC) 9 5'-0" 8'-0" INT SWING DBL (SC) 10 2'-8' 8'-0' INT SWING 11 2'-8" 8'-0" G �SC INT SWIN SC� 12 2'-8- 8'-0' MIN INT SWING (SC) . I" THIK, SELF 1 3/��­ CLOSER 13 2'-B" 8'-Om INT SWING (SC) MIN 1 3/8" THK, SELF- 00SE.R 14 2'-8" 8'-0' INT 15 2' -8" 8'-0" SWING INT SW " 2 N GARAGE::., LEVEL WINDCON *1,5�1111,'OHEDULE SIZE HEAD HT MARK TYPE NOTES WD HGT ELEV 1 2'-9" 8'-0" 511: EUGHT i 9 _O� 2 2:-9" 8'-0* SILEUGHT gi-om 3 2 -8 5'-6 CS914T W-00 4 2'-8* 5'-6* CSYNT I b 8-0 5 2-8" 5'-6" C`�;VNT 81-0* 6 6'-0* 5'-6" CSMN1' DOUBLE: 8i-of. 7 4'-Oo 4'-C FIXEC, DOUBLE 1 a-04 00 C-4 W5 _(003 UP I 19RISE:RS@6.96" EACH 11m TREADS w/ 1" LB. 4'-0" 8'-4" BULLNOSE L0BBY ool 4" 0 201-10" x 151 2 FA GARAGE 12'-10" C1g 49'-4" x 38'-10" 4'-4" Z07) STORAGE ROOM 91 CL, lot 90 KIM 14'-6m EQUIP. TO BE ELEVATED ON PECIESTALS/STANDS ABOV E DIFE (DESIGN FLOOD ELEVATION) OF NAVD 16.4 S-fl PF OC131 M7 T-110" -.,,;�.,'TORAGE 7'C'g 1? �8�"x �'r FoRu :114) 120 06' 4"� .7f',,r4 23'-9" 67'-4" 14'-6" )RAGE 9f cig 14ve� 9 Ck 1110001-01111 2'-0" op 4--W 04 04 1:3 1 21 Li 1 110 POOL ABOVE IF NON -HABITABLE AREA BELOW ELEVATED DECK c) NOTE: E )UIP. TO BE ELEVATED ON 1 EDIESTALS/STANDS ABOVE DIFE (DESIGN FLOOD ELEVATION) OF NAVD 16.4 005 X-8- raAAKI L L el I WT1111111 W WAAMI kq LIVING AREA CALCULA"TtiON 1) 1`3T FLOOR LIVING 1 SF 2) 2ND FLOOR LIVING 12?63 SF 3) L()BBY 335 SF ej-i 9 SF D11::_:'rAIL AREA CALCULATION 1) '1 ST FLOOR LIVING 2.611 SF 2)21 'qD FLOOR LIVING 1263 SF 3) LOBBY 2,35 SF BALCONY 1 55 SF BALCONY 2 61 SF BALCONY 3 200 SF BON US STORAGE 809 SF CON(ERED ENTRY 48 SF GASAGE 1877 SF OUTDOOR LIVING 356 SF 7 615 SIF 200 SERIES KEYNO"FES 200 - MIRROR 201 - BUILT-IN CABINETRY 202 - OPEN SHELVES 203 - CUSTOM CLOSET INTERIOR 2D4 - TEMPERED GLASS SHOWER ENCLC S URE 206 - CURB FOR SHOWER M - TROUGH FOR POOL INFINITY EDGE 207 - DRAPERY POCKET 208-.. 209 - ADJACENT WALLS TO HAVE MIN R-1 I I NSUL & MIN 1/2"GYP SO ON GARAGE SIDE FOR GARAGE SEPARATION 210 - MIN 5/8"TYPEW GYP BD FOR GAFU�GE CLG BELOW HABITABLE ROOMS 211 - T.S. COLUMN IN WALL 212 - T.S. COLUMN IN DECORATIVE COUPOST 213 - 42" HIGH CMU WALL 214 - 8"x16" ENGINEERED SMART FLOOD VENT PROVIDING 200 SF OF FLOOD COVERAGE 215-.. 216- 217- 218- 219- 220- pemi sem 0� iu.0�10 CN LO 7 ee-41 I NOTE: DESIGN FLOOD ELEVATION IS AT 16.4 NAVD. PER FSC R322.1.8 BUILDING MATERIALS AND INSI ALLILATION METHODS USED FOR FLOORING & INTERIOR AND EXTERIOR WALLS AND WALL COVERINGS BELOW THE DESIGN FLOOD ELEVATION (DFE) SHALL BE FLOOD DAMAGE RES STANT MATF: R ALS THAT CONFORM TO THE PROVISIONS OF FEMA TB-2. MECHANICAL, ELECTRICAL, & PLUMBING SYSTEMS BELOW DFE ARETC) BE DESIGNED & INSTALLED TO PREVENT YVATER FROM ENTERING ORACCUMULATING WITHIN THE COMPONENTS 4-J ANDTO RESIST HYDROSTATIC AND HYDRODYNAMIC LOADS u AND STRESSES PER FBC R322.1.6 Em� w 4-3 FLOC D VENT CALCULATION 8"xl 6' ENGINEERED FLOOD VENTS THAT CA PROVIDE 200 SF OF FLOOD COVERAGE u GARAGE 1877 SF1200 = 9.3 = 10 VENTS LOBBY &STORAGE AREAS 1144SF/200=5.7=6V: NTS BELOW POOL DECK AREA 1074 SF1200 = 5.4 = 6 VENTS �4 THE DESIGN OF THE FLOOD VENT OPENINGS WILL PROVIDE FOR EQUALIZATION OF HYDROSTATIC F LOOD 0 FORCE S ON EXTERIOR WALLS BY ALLOWING FOR I HE AUTOMATIC ENTRY AND EXIT OF FLOODWATERSAS 4-J cd SPECIFIED IN SECTION 2.7.2.2 OF ASCE 24. PER F13C ;.A R3221.2 FOOT NOTE 2.1 THE BOTTOM OF EACH OPENING SHALL BE NOT PIDRE THAN 4� FOOT ABOVE THE HIGHER OF THE FINAL INTERIOR FLOOR ANDTHE FINISHED EXTERIOR GRADE IMIVEDIATELY BELCW THE OPENING Q) > 4-� Job No. 12C.2011 -DUCI A211�')c BY DW GS io.5. OIST FLOOR DOOR SCHEDULE SIZE MARK, TYPE NOTES WD HGT 1 101 W-00 1 l'—O" SLD GLASS OXX 102 9'-0- 9'-0" SLD GLASS OXX 103 15-0" W-00 SLD GLASS OXX POCKET SGO 104 6'-0" 10'-0" SLD GLASS 105 20'-0" 10'-0" SLD GLASS OXXO 106 12'-0o 10'-0* SLD GLASS OXX 101 2'-6" 8'-0" Pocket Door 108 2'-8" 8'-00 INT SWING (SC) 109 2'-6" 8'-0" Pocket Door 110 2'-1" 8'-0* SW G -- SCI ill 2'-8- 8'-0- INNT T SW�N NG SC —7 112 2'-8" 8'-0* INT SWING SC -- ISC 113 2'-8" 8'-0" INT SWING 114. 4'-0 j- 8'—Om INT SWING DBL (SC) 115 2'-6 8'— 0.1 INT SW S 116 2'-6" 8'-0" W�NG INT S NG S 117 2'—Bw 8'-0" 1 ST1 FLOOR WIN D()W SCHEDULE SIZE HEAD HT: MARK TYPE NOTES WD HC;T ELEV 101 4`-00 1'- 6' FIXED 4'-6" BETWEEN CAB'S, V-ER-IF-Y WT. 102 4'-0' l'-- 6 FIXED 4:-6" BETWEEN C&S, VERIFY —HT. 2'-6" 5'- C CSMNT 9,-0: .103 104 2'-0" 5'- 0 CSMNT 9-0 105 2'-0": 5'- 0" CSMNT 9:-00 106 2'-0" 5- C " FIXED 9-0- 107 2'-0* 5'- 0 " CSMNT 9:4111 108 2'-0" 5'- 0 " CSMNT 9,-V 109 5'-4" 6'- 0" CSMNT DBL 9-00 1 110 2'-8" 5'-()" ' CSMNT W-00 iiII/ FIXED -GLASS ABV a GUARD SEAT L R 7R -:! 1 7 12'.2" .... 9; UTIL zo� 10, C1 J zTfT " L I p TR) 0 -x(on, 1032 LIBRARY 45; Qz 10`4711- 0. 0 1111 1112 100 2 101 0 C) 0 cac- OQ NTNS COOKTOP yd 21'l HOODAEV r;;71 13taan LO ;fir — — iL — T t', LIPPER STAR DETAILS 13'l FLOOR TO FLOOR -,.:2 RISERS @ 7,09" EACH �T4- f Ill w/ 1" BULLNOSE OPEN TO �78 BELOW -�J.j UP i . L 4--0- 8'-4" Rim FROM BALCO GUAR- 11, Cig 21-1 112 C, a nos IR91 I ta owl 0 11 DINING ItIC-19 16-13" x 11' 16-1 F111111T11111111 15-10" x 23' 16111MRM 7w, I;4mj:1fx&i 18 RISERS @ +-7 1/4" VERIFY HEIGHT OF GRAE TO ELEVATED DECK FOR RISER HEIGHT 12" TREADS W/ 1" BULLNC 0 Ill 112 113 114 115 116 117 104 SUN 24'-10" SHELF 8 )N EDGE oa GPXAT ROOM 0PT1(-.).l Coffer C1g ll'/11'-4" 25'x 23"l POOLl 20--6" 20'l 01 2'-C 21'-4' SPA l� coj 17 14'-0" J'l 4'.8" 41 1 1 �1. MASTER BEDROO-A Coffer C 101-611/111 19,40, x I'l 14!-0" �*IJN v C �G —LIVING AREA CALCULA-rION 1) 1 ST FLOOR LIVING 2611 SF 2)2ND FLOOR LIVING 1263 SF 3) LOBBY 335 SF 4� �09SF DETAIL AREA CALCULATION Tl 1) 1 ST FLOOR LIVING 2611 SF 2)2ND FLOOR LIVING 1263 SF 3) LOBBY 335 SF BALCONY 1 55 SF BA LCONY 2 61 SF BALCONY 3 200 SF BONUS STORAGE 809 SF CCIVERED ENTRY 48 SF GARAGE 1877 SF OUTDOOR LIVING 356 SF 7615 SF C9 200 SERIES KEYNO"rES 200 - MIRROR 201 - BUILT-IN CABINETRY 202 - OPEN SHELVES 203 - CUSTOM CLOSET INTERIOR 204 - TEMPERED GLASS SHOWER ENCLOSURE 205 - CURB FOR SHOWER 206 - TROUGH FOR POOL INFINITY EDGE 207 - DRAPERY POCKET 208-.. 209 - ADJACENT WALLS TO HAVE MIN R 11 INSUL & MIN 1/2'GYP BD ON GARAGE Sl FOR GARAGE SEPARATION 210 - MIN 5/8" TYPEWGYP BD FOR GARAGE CLG BELOW HABITABLE ROOMS 211 - T.S. COLUMN IN WALL 212 - T.S. COLUMN IN DECORATIVE COLIPOST 213 - 42"HIGH CMU WALL 214 - 8"l ENGINEERED SMART FLOOD ll.l PROVIDING 200 SF OF FLOOD COVERAGE 215-.. 216- 217- 218- 219- 220- T )L�ek &�;� b�. 06cr Calm -Frc. Marl 1�r"Cllt)o 1ST FLOOR P!:-AN SCALE: 1/l V-0" (2 00 KEVIS11 permit sets N Cn 7. Fool �7 C, 0-olool ;4 C 4 u 4-) U Moll' loll 4-l) u -oo) A C �ou No. fi:, 0011 I L 0011106 I.-NIA-AAl A2 11 2ND FLOC�1111`1 DOOR SCHEU�',11ULE SIZE MARK WD HGT TYF E, NOTES 201 8'-0" 8'-0" SLD G06S 202 8'-0" 4'On SLD GLASS 203 2:— 6" INT SWING 5C 204 2 —6" V-0 SWING C S I SC � 205 2'-8" 8—'-:0—' S INT SWING SC 206 2:-8" 8n�-�HNT SWING S S 207 2-8 8r Off _T_ I INT SWING S 208 2'-8" t �—O INT SWING :SC 209 2'-8" 8—� S INT SWING "K C 210 2'-6" 8'—O� INT SWING ISC 211 2'-6" 8'-0" INT SWING isc 212 2'-8" 8'-0" INT SWING I,SC 213 2'-6" 8'-0" Pocket Dr Dr 214 2 6" -0 INT SWING sc FLOOR Will"111DOW m SCHEDULIE.' SIZE HEAD HT MARK TYPE : --- NOTES VVID HIST ! ELE 201 5'­4" 5'-0" CWNT DEIIi 8,-0 EGRESS 202 J .0" 7' 8'-0" FIXED U-40 203 3, -.1)" 8,-0" FIXED 204 J:­O" 8'-0" FIXED 205 5'---0" 5'-0" CSIVINT MI. li-:bw EGRESS 206 21- -0" 5'-0" MINT 8'-0 207 41­0" T-O" FIXED 6'-_ 208 5'-Om CSIANT 8 -0" 209 2 1)" S-0� FIXED 8 0 210 J 1)" 3'-0" HOR Vb* 211 3'-0" -SLIDE! HOR S DIE: -bw FF I F 200 SERIES KEYN(,...:I'T'ES 200 - MIRROR 201 - BUILT-IN CABINETRY 202 - OPEN SHELVES 203 - CUSTOM CLOSET INTERIOR 204 - TEMPERED GLASS SHOWER ENC', LOSURE 205 - CURB FOR SHOWER 206 - TROUGH FOR POOL INFINITY EDGE 207 - DRAPERY POCKET 208-.. 209 - ADJACENT WALLS TO HAVE MIN R 11 INSUL & MIN 112"GYP SO ON GARAGE SIDE FOR GARAGE SEPARATION 210 - MIN 5/8" TYPEWGYP BID FOR GARAGE CLG BELOW HABITABLE ROOMS 211 - T.S. COLUMN IN WALL 212 - T.S. COLUMN IN DECORATIVE COL'POST 213 - 42" HIGH CMU WALL 214 - B"xl6" ENGINEERED SMART FLOOE: VENT PROVIDING 200 SF OF FLOOD CCVERAGE 215, 216- 217- 218- 219- 220- C�� (!:�" cr 61((s J�-lc r azu'ptl ,lyl(ml 00 REVISIOTS BY DATE - Tm Apermit sets GS 10.6,2018 L6 6 Cov �—a C1110 U V-14 I q 4-3 #1 lull MIN ! MIN qwn m nnD Di &Ki 1/-* - I -V -LIFE SAFETY WAFNING This symbol identi Pes Life Safety Warnins that 0 should be read and given special attentic to all persons installing trusses. SPACING NOTE All trusses are to be set 2'-0" on center except as noted. MULTIPLE PLY TRUSSES MUST BE FAS--=NED TOGETHER PER ENGINEERING BEF(2E SETTING. REFER TO ENGINEERING DRPVING A TO DETERMINE IF MULTIPLE PLY. . WITH SPANS LONGER THAN 30'BY THE PEAK CONSULT BCS] W SDArt or less 60 degrees or less Tag line -Eif 1/2 alien approx. REFER TO BCSI Truss must be set this way if crane is used. Truss is an example, your truss may not match. Insist crane operator sets truss this way, Tag I line <---Appm 213 I& Of Spin, REFER TO BGI Truss must be set this way icrane is used. Truss is an example, your trus may not match. Insist crane operator sets tin this way. All load beading walls, headers, I beams, & lintels must be in Oace I at indicated height before trusses i A arel installed. A, 14 0 AIR HANDLER NOTE Unless noted elsewhere on this layout, these trussEs are not designed for air handle�s in the roof or for any other A/C requirements. This may be in conflict with building code and A/C Design requirements. Consult with Building Department and A/C Contractor. WARNING The size of these trusses makes it necessary that they e set by a profeesional builder familiar with and experienced in the problems and dangers of setting large span trusses. The builder and erector should consult with an engineer licensed in Florida specializing in wood roof trusses about the safe erection of these trusses. The engineer should be at the job site when trusses are erected to provide supervision and advice. SEAT PLATES BY CHAMBERS TRUSS to bottam card as l Hatch Legend i BRG WALL �- 34' 1 GV BRIG WALL @ 221- 411 10Z I I I J 16REPRESENTS A HANGER I HANGER SCHEDULE USE HUS26 FOR 2X4, THD46 FOR 4X2 EXCEPT AS SHOWN CARRIED TRUSS CARRYING TRUSS HANGERiD FASTENER FOR CARRIED TRUSS FASTENER FOR CARRYING TRUSS *Please refer to Standard Engineerind package for general instuction on installing hangers 10d=0.148" x 3'. 16d=O. 162" x 3 1/2" DCONNECTIONS DESIGNED AND SUPPLIED BY OTHERS ADo not stand on trusses until they are braced per BCSI & properly nailed to straps METAL ROOFS SHOW IMPERFECTIONS. SPECIAL INSTALLATION CARE MUST BE TAKEN. Do not set floor trusses upside down! Refer to engineering drawings. and hangers .11. 55-04-00 48-00-00 7-04-00 Z Z Z Z Z "krjllrj r' r- F' r' r' rJ r rJ r rj rj r rJ rJ r rJ P r P r-r r- rJ r ri ri rr- Ill Ill 17 r r1 rJ r rJ rJ r rJ rJ r r' rJ r it -cTE if n -L -LL L A00V --L J3 c) Do 9 is '0 J3 -L LJ5 5-00-00 Jr is J3 3-00-00 is J3 C? U --- Li 11 J —A I J5 J3 ri ri -11- I'LL — D-Oo IT- 0-00 4X2 FLOOR TRUSSES 24" DEEP 24'0 C. SPACING 16-07-13 J3 FILM J� 4X2 FLOOR TRUSSEI 24" D z-EP 24'O.C. SPACING. �JCING J3 FLM FILL C? J3 J3 FILM -------------- ZY 9 FILL it FILM FILK T 17-03-13 Z FUM FLK FLM 7-04-00 CIO UJ FLJ 0 FLJ C%4 C? LU I uJ 4 FLJ 17-04-00 C�o Fl Lu C? Fl U) C? IMATE;H PUN" --------- FLJ FLJ 0 LL 9 2-00-00 FLI X dq FLI FUH C) < it J5 FLG MV4 J3 FLG is 7 is FLG LU X Q is 0 9 0 J6 5-00-00 -C 0 U FLG U) 5-00-00 -1-1 6 is =1 JU Lu 0 (D\ 0 -L 0 Lh 0 A is FUG 0 9 Do 0 is J5 0 0 J3 —J U- J3 FLG C? L 0 X J 1 C? '11 A r' r' rJl1r' r' r rJ rJ rJ rJ of rJ r r 1-1 Ill IFJII Ill ril Of 21-02-00 19-04-00 91-06-00 5-04-00 55-04-00 TOP OF ALL FLOOR TRUSS LEDGERS 0) 23l 9" THIS LEVEL. BOTTOM OF ALL ROOF TRUSS LEDGERS @ 22l 4" THIS LEVEL. HIP CARRIER LOCATED AS DIMENSIONED ON CORNIDER JACKII ARE NOT BEVELED. SEE STANDARD CORNER JACKS ONLY - 2r CORNER DETAIL OVERHANGS NOT SHOWN FOR CLARITY M MA (3 w Z 0 Z Nuo SQUARE CUT END 4X2 TOP CHORD LEDGER HEIGHT VARIES END DETAIL: TYPICAL FLOOR FABRICATION AGREEMENT TRUSSES CANNOT BE STARTED UNTIL THIS AGREEMENT IS SIGNED & RETURNED e undersigned acknowtedges and agrees: 1. Trusses will be made in strict accordance with this truss placement diagram layout, which is the sole authority for termining successful fabrication at the trusses. 2. All dimensions in this layout have been verfed by the undersigned. 3. Unless written notice is provided by certified mail to Chambers Truss within ten (10) days of delivery the dersigned agrees that no backcharges will be allowed. In the event such written notice is furnished Chambers Truss all have three (3) business days in which to begin repairs required, or to substitute other trusses, at Chambers option. ter 10 days of delivery remedy will be according to Florida statute 558. 4. The undersigned acknowledges receipt of 'BCSl' summary sheet by TPI & WTCA. 5. Delivery is to job site. It is the buyers responsibilfty to make the job site suitable for delivery. Chambers Truss has sole authority to determine the suitability of the job site or a portion of the job site for delivery. Chambers Truss vvill responsible for dump delivery only. The buyer is responsible for additional delivery expenses it Chambers Truss has redeliver because job site is not prepared for delivery or buyer is not prepared for delivery of trusses. Buyer is 3ponsible to Chambers Truss for towing costs due to site oondifions. 6. Price as shown in paragraph 7 below is subject to change ff any changes are made in this layout. A $50 per hour for revisions may be charged by Chambers Truss. 7. This is a PURCHASE ORDER to Chambers Truss of the sum agreed to, or if no agreement a reasonable price. ioil will be made on delivery and paid within tens of net on delivery. Invoice may be made at scheduled date of livery 6 buyer Cannot accept delivery of fabricated trusses. The undersigned agrees to pay Chambers Truss ded a sum not p ld in terms. 8. Silignature or initials anywhere on this sheet constitutes agreement to all term herein. 9. In consideration of Chambers Truss extending credit for this material the undersigned unconditionally guarantees yment when due of any and ail indebtedness owed to Chambers Truss by any entity receiving material and the dersigned agrees to pay such indebtedness including attorneys fees, 9 default in payment for material be made by the 10. In the event of any litigation concerning this agreement, the ittems furnished hereunderr or payments referred ten, the parties agree that the sole venue for any such action will be Saint Lucie County, Florida. 11. Design responsibilities are per .... National Standard And Recommended Guidelines On RespDrisibilifies f nstruction Using Metal Plate Connected Wood Trusses ANSIiTPI/WTCA 4 - 2002'"' 12. Warranty is per Chambers Truss Warranty attached. A spreader bar may be required per "BCSI" to prevent injury & damage. .d9al Multiple ply trusses must be fastened together per engineering before they are set, failure to do so can result in roof collapse. .996h. Temporary and permanent bracing are required and can save life and property and is the responsibility of the truss erector. Study the contents of the information packet included on delivery before setting trusses. .111191ill Trusses must be set and braced per design to prevent injury & damage. Trusses must be set plumb and square -.1111111M. Do not set bunks or stack of plywood, roofing material or any other concentrated loads on trusses, this can cause collapse. DO NOT JINSTALL TRUSSES USING THIS USE PLAN DELIVERED WITH TRUSSES TO SET TRUSSES CHAMBERS TRUSS INC ILW 310* uleancler Avenue Fort Pierce, Florida 34982-6423 800-551-5932 Fort Pierce 772-465-2012 Fax 772-465-8711 Vero Beach 772-569-2012 Stuart T72-286-3302 Web Site: CHAMBERSTRUSS.COM Email: MAIL@CHAMBERSTRUSS.COM LO&3INGADESIGN CRITER RE�CIBUE PER CODE SUCH AS S8C IW4.6.1 DESIGN CRITERIA County Saint Lucie County Building Department Saint Lucie County Wind Design Criteria ASCE 2010 Wind Design Method MWFRS(Directiorl hybrid Wind ASCE 7-10 Roofing Material Metal Loading in PSF Roof R.C.L. Floor Top Chord Live 20 40 Top Chord Dead 15 4.2 20 Bottom Chord Live *10-Non Concicurent 10 Bottom Chord Dead 10 3 5 Total Load 55 7.2 75 Duration Factor 1.25 1.00 WindSpeed 170mph Top Chord C.B. Sheathing by builder Bottom Chord C.B. Sheathing by builder Highest Mean Height 37' Building Type Enclosed Building Category II: Non Restrictive Exposure Category l Flat/ unobstructed/ exposed to wind over water... Miles from Ocean 0 Conforms to Florida Building Code 2017 R.D.L.=Restraining Dead Load C.B.=Continuous Bracing Verify DESIGN CRITERIA shown above with the building department and your engineer. Design Criteria is the responsibility of the Building Designer and/or Engineer of Record Chambers Truss Inc. Drawing Name: 75580 SCALE: 1/4" = V-011 291 total trusses, 65 unique designs Designer: BLW Reviewed by: Date: 11/13/18 FOR Sion Homes DESCRIPTION: ACQUAVISTA LOT #3 Page 2 of 3 CUSTOMER INITIALS EACH PAGE 75580 a FABRICATION AGREEMENT TRUSSES CANNOT BE STARTED UNTIL THIS AGREEMENT IS SIGNIL, A! =LIFE�SAFETY WARNING IThis symbol identifies Life Safety Wa— - s tha, should be read and given special atte--. 3 to all persons installing trusses SPACING NOTE All trusses are to be set 2'-0" c- center except as noted. MULTIPLE PLY TRUSSES MUST BE 7- z-: ENED TOGETHER PER ENGiNEERING 13=-=--�E SETTING. REFER TO ENGINEERING WING ,1k TO DETERMINE IF MULTIPLE I'L NTH SPANS LONGER THAN 31Y BY THE PEAK CONSULT BCSI =7 60 degmes or less Tagline IF2 spart approx, REFER TO IBCSI Truss must be set this way if crane is used. Truss is an example, your tnuss may not match. Insist crane operator sets truss this way. 0 Spreacr T�, line <--Ai W 112 of Spii REFER TO is[ Tnjss must be set this war crane is used Tmss is an example, your he may not match. Insist chains operator setruss this way. All load beading walls, heacars, beams, & linte'lls must be in [lace l at indicated height before trLsses are installed. AIR HANDLER NOTE Unless noted elsewhere on this layout, these trussis are not designed for air handlers in the roof or for any oier A/C requirements. This may be in conflict with building cde and A/C Design requirements. Consult with Building Departmint and A/C Contractor. /1\ WARNING /I'\ /a% a * The size of these trusses makes it necessary that they e set by a pr�eesional builder familiar with and experienced in the problems and dangers of setting k7ge Span trusses The builder and erector should consult with an engineer licensed in Flirida specializing in wood roof trusses about the safe erection of these trusses. The engieer should be at the job site when trusses are erected to provide supervision art advice. I Recommended STRONGBACK for Floor Trusses Refer to information on truss engineering drawings. l 1 (2) led nails @ top & bottom of 2x4 vertical blocki 2x6 (MIN) STRONGBACK restrained at each end. are recommended to MINIMIZE i, nails @ each vertical. Locate STRONGBACK . as do to bottom cord as possible- 0 C (3) 0 IL SQUARE CUT END 4X2 TOP CHORD LEDGER HEIGHT VARIES END DETAIL: TYPICAL FLOOR A Do not stand on trusses until they are braced per BCS1 & properly nailed to straps and hangers HI 'METAL ROOFS SHOW IMPERFECTIONS. SPECIAL INSTALLATION CARE MUST BE TAKEN. I Do not set floor trusses upside down! Refer to engineering drawings. w undersigned acknowledges and agrees: 1. Trusses will be made in stict accordance with this truss placement diagram layout which t, !termining successful fabrication of the trusses. 2. AJI dimensions in this layout have been verified by the undersigned. 3. Unless written notice is provided by certified mail to Chambers Truss within ten (10) days o. dersigned agrees that no backcharges will be allowed. In the event such written notice is fumished Chan, all have three (3) business days in which to begin repairs required, or to substitute other trusses, at Channi ter 10 days of delivery remedy will be according to Florida statute 558. 4. The undersigned acknowledges receipt of 'BCSI' summary sheet by TPI & WTCA- 5. Delivery is to job she. It is the buyers responsibility to make the job site suitable for delivery. Chambers Trui a sole authority to determine the suitability of the job site or a P01110n at the job she for delivery. Chambers Tru responsible for dump delivery only. The buyer is responsible for additional delivery expenses 9 Chambers Trin redefiver because job site is not prepared for delivery or buyer is not prepared for delivery of trusses. BL 5ponsible to Chambers Truss for towing costs due to site conditions. 6. Price as shown in paragraph 7 below is subject to change it any changes are made in this layout A $50 pE for revisions may be charged by Chambers Truss. 7. This is a PURCHASE ORDER to Chambers Truss of the sum agreed to, or if no agreement a reasonable ioice will be made on delivery and paid within terms of net on delivery. Invoice may be made at scheduled d livery 9 buyer cannot accept delivery of fabricated trusses. The undersigned agrees to pay Chambers asonable attorneys fee for collections in event of payment not fime� made. 1-1/2 % per month service charge ded for all sums not paid within terms. 8. Signature or initials anywhere on this sheet constitutes agreement to all terms herein. 9. In consideration of Chambers Truss extending credit for this material the undersigned uncoluktionally guari yment when due of any and all indebtedness owed to Chambers Truss by any entity receiving material at d . e . Signed agrees to pay such indebtedness including attorneys fees, if default in payment for material be made 10. In the event of any litigation concerning this agreement, the items furnished hereunder or payments refer !rein, the parties agree that the sole venue for any such action will be Saint Lucie County, Florida. 11. Design responsibilities are per .... National Standard And Recommended Guidelines On Responsibilitie :Instruction Using Metal Plate Connected Wood Trusses ANSIfTPI/WTCA 4 - 2002... 12. Warranty is per Chambers Truss Warranty attached. A spreader bar may be required per "BCSI" to prevent injury & damage. -010011il Multiple ply trusses must be fastened together per engineering before they i set, failure to do so can result in roof collapse. .01911111lill Temporary and permanent bracing are required and can save life and prope and is the responsibility of the truss erector. .01111111111h, Study the contents of the information packet included on delivery before setting trusses. .411111111111h. Trusses must be set and braced per design to prevent injury & damage. .Adhill Trusses must be set plumb and square Do not set bunks or stack of pooOZd, roofing material or any other concentrated loads on trusses, this can cause collapse. aaa DO NOT INSTALL TRUSSES USING THIS USE PLAN DELIVERED WITH TRUSSES TO SET TRUSSES CHAMBERS TRUSS IINC Fort Pierce, Florida 34982-6423 800-551-5932 Fort Pierce 772-465-2012 Fax 772-465-8711 VeroBeach 772-569-2012 Stuart T72-286-3302 Web Site: CHAMBERSTRUSS.COM Email: MAIL@CHAMBERSTRUSS.COM REVIEWED FOR CODE COMPLIANCE ST. LUCIE COUNTY 00 Co BOCC unty, Permitting FILE COPY LOADINGIDESIGN CRITERIA REDLICHIL PER CODE SUCH AS SEIC 161 DESIGN CRITERIA County Saint Lucie County Building Department Saint Lucie County Wind Design Criteria ASCE 2010 Wind Design Method MWFRS(Directional)/C-C hybrid Wind ASCE 7-10 Roofing Material Metal Loading in PSF Roof R.D.L. Floor Top Chord Live 20 40 Top Chord Dead 15 4.2 20 Bottom Chord Live *10-Non Conccurend 10 Bottom Chord Dead 10 3 5 Total Load 55 7.2 75 Duration Factor 1.25 1.00 Wind Speed 170mph Top Chord C.B- Sheathing by builder Bottom Chord C.B. Sheathing by builder Highest Mean Height 37' Building Type Enclosed Building Category If: Non Restrictive Exposure Category D> FIaV unobstructed/ exposed to wind over water... Miles from Ocean 0 Conforms to Florida Building Code 2017 R.D.L-=Restraining Dead Load C.B.=Continuous Bracing Verify DESIGN CRITERIA shown above with the building department and your engineer. Design Criteria is the responsibility of the Building Designer and/or Engineer of Record Chambers Truss Inc. Drawing Name: 75580 SCALE: 1/4" = V-011 291 total trusses, 65 unique designs Designer: BLW Reviewed by: Date: 11/13/18 FOR Sion Homes DESCRIPTION: ACQUAVISTA LOT #3 Page 1 of 3 CUSTOMER INITIALS EACH PAGE 75580 =LIFE SAFETY WARNIIG This symbol identifies Life Safety Warnings tit should be read and'given special attention toll persons, installing trusses. I SPACING NOTE All trusses are to be set 2'-0" on center except as noted. MULTIPLE PLY TRUSSES MUST BE FASTEND TOGETHER PERIENGINEERING BEFORE SETTING. REFER TO ENGINEERING DRAWIN TO DETERMINE IF MULTIPLE PLY. A WITH SPANS LONGER THAN 30'� BY THE PEAK CONSULT BCS] 30' Sp4n or less 60 degrees or less -E�— 112 span )? aplsox. Ta�fir. <--Am= 2J3 6D 112 of spar. REFER TO SCSI REFER TO BCSI Truss must be set this way if crane Is w Truss must be set this way if cran% used. Truss is an example, your truss may not =tch. Truss is an example, your truss mayrt match. Insist crane operator sets truss this we Insist crew operator sets truss th way. All load bearing walls, headen, beams, & lintels must be in plwe at indicated height before trussas A are � installed. A 0 AIR f L.Iriless noted elsewhere designed for air handle requirements. This may be Design requirements. Com 0 LNDLER NOTE I this layout, these trusses Core not ; in the roof or for any otherA/C I conflict with building code and A/C It with Building Department ind A/C W I ARNING The size of these trusses makes it necessary that they a set by a profeesional builder niliar with and experienced in the problems and dangers of setting large span trusses. -le builder and erector should consult with an engineer licensed in Florid6 specializing wood roof trusses about the safe erection of these trusses. The engineer should be at the job site when trusses are erected to provide supervision and advice. I SEAT PLATES BY CHAMBERS TRUSS Hatch Legend BRG WALL @ 34- BRG WALL @ 221- 411 J qREPRESENTS A HANGER HANGER SCHEDULE I IRF HUS26 FOR 2X4. THD46 FOR 4X2 EXCEPT AS SHOWN CARRIED TRUSS CARRYING -�M US as TRUSS HAN' ER 10 i FASTENER FOR CARRIED TRUSS FASTENER FOR CARRYING TRUSS *Please refer to Standard Engineering package for general instuction on installing hangers 1 Od=O. 148" x 3" � 16d=0.162" x 3 112" ADo not stand on trusses untO they are braced per BCSI & properly nailed to straps and hangers 11 METAL ROOFS SHOV'V IMPERFECTIONS. SPECIAL INSTALLATION CARE MUST BE TAKEN. HIP CARRIER LOCATED AS DIMENSIONED ON LAYOUT V A FIN ER ACKS CORNDER JAC CO C J _L ARE NOT BEVE D. LSED SEE STANDAR D W I ENGINEERING Z X koz 00 24'O.C. THRU CORNERJACKS ONLY — CORNER DETAIL OVERHANGSNOT SHOWN FOR CLARITY 4.5r- 4 - 0 0 PLUMB CUT END 2X4 70P CHORD WALL HEIGHT VARIES END DETAIL: TYPICAL ROOF FABRICATION AGREEMENT TRUSSES CANNOT BE STARTED UNTIL THIS AGREEMENT IS SIGNED & RETURNED he undersigned acknowledges and agrees: 1. Trusses will be made in sW accordance with this truss placement diagram layout which is the sole authority b etermining successful fabricabon of the trusses. 2. All dimensions in this layout have been verified by the undersigned. 3. Unless written notice is provided by caffified mail to Chambers Truss within ten (10) days of delivery the ridersigned agrees that no backcharges will be allowed. In the event such written notice is furnished Chambers Truss hall have three (3) business days in which to begin repairs required, or to substitute other trusses, at Chambers option. fter 10 days of delivery remedy will be according to Florida statute 558. 4. The undersigned acknowledges receipt of 'BCSI* summary sheet by TPI & WTCA. 5. Delivery is to job site. It is the buyers responsibility to make the job site suitable for delivery. Chambers Truss has IS sole authority to determine the suitability of the job site or a portion of the job site for delivery. Chambers Truss will a responsible for dump delivery only. The buyer is responsible for additional delivery expenses if Chambers Truss has ) redeliver because job site is not prepared for delivery or buyer is not prepared for delivery of trusses. Buyer is %ponsible to Chambers Truss for towing costs due to site conditions. 6. Price as shown in paragraph 7 below is subject to change If any changes are made in this layout A $50 per hour .a for revisions may be charged by Chambers Truss. 7. This is a PURCHASE ORDER to Chambers Truss of the sum agreed to, or if no agreement a reasonable price. ivoioe will be made on delivery and paid within terms of net on delivery. Invoice may be made at scheduled date of Blivery if buyer cannot accept delivery of fabricated trusses. The undersigned agrees to pay Chambers Truss lasonable attorneys fee for collections in event of payment not timely made. 1-1/2 % per month service charge will be Ided for all sums not paid within terms. 8. Signature or initiaL9 anywhere on this sheet constitutes agreement to all terms herein. 9. In consideration of Chambers Truss extending credit for this material the undersigned unconditionally guarantees 3yment when due of any and all indebtedness owed to Chambers Truss by any entity receiving material and the idersigned agrees to pay such indebtedness including attorneys fees, it default in payment for material be made by the 10. In the event of any litigation concerning this agreement, the items furnished hereunder or payments referred to ,rein, the parties agree that the sole venue for any such action will be Saint Lucie County, Florida. 11. Design responsibilities are per .... National Standard And Recommended Guidelines On Responsibilities For onstructon Using Metal Plate Connected Wood Trusses ANSIrrPYWTCA 4 - 2002'"' 12. Warranty is per Chambers Truss Warranty attached. A spreader bar may be required per "BCSI" to prevent injury & damage. Idialle, Multiple ply trusses must be fastened together per engineering before they are set, failure to do so can result in roof collapse. -dillikils- Temporary and permanent bracing are required and can save life and property and is the responsibility of the truss erector. Study the contents of the information packet included on delivery before setting trusses. Idgillihs. Trusses must be set and braced per design to prevent injury & damage. .ddhkl. Trusses must be set plumb and square .1966, Do not set bunks or stack of plywood , roofing material or any other concentrated loads on trusses, this can cause collapse. DO NOT INSTALL TRUSSES USING THIS USE PLAN DELIVERED WITH TRUSSES TO SET TRUSSES CHAMBERS TRUSS INC 3105 Olean er venue k2h Fort Pierce, Florida 34982-6423 800-551-5932 Fort Pierce 772-465-2012 Fax 772-465-8711 Vero Beach 772-569-2012 Stuart 772-286-3302 Web Site: CHAMBERSTRUSS.COM Email: MAIL@CHAMBERSTRUSS.COM DESIGN CRITERIA LOADINGDESIGN CRITERIA REDUCIBLE PER CODE SUCH AS SBC 1604.8.1 County Saint Lucie County Building Department Saint Lucie County Wind Design Criteria ASCE 2010 Wind Design Method MWFRS(Directional)/C-C hybrid Wind ASCE 7-10 Roofing Material Metal Loading in PSF Roof R.D.L. Floor Top Chord Live 20 40 Top Chord Dead 15 4.2 20 Bottom Chord Live *1 O-Non Conecurent 10 Bottom Chord Dead 10 3 5 L3 Total Load 55 7.2 75 Duration Factor 1.25 1.00 LU FJ, cm Wind Speed 170mph > Top Chord C.B. Sheathing by builder dCq 4— Bottom Chord C.B. Sheathing by builder Highest Mean Height 37' Lu CZ Building Type Enclosed Building Category II: Non Restrictive Exposure Category D> RaV unobstructed/ exposed to Wind over water.. Miles from Ocean 0 Conforms to Florida Building Code 2017 R.D.L.=Restraining Dead Load C.B.=Continuous Bracing Verify DESIGN CRITERIA shown above with the building department and your engineer. Design Criteria is the responsibility of the Building Designer and/or Engineer of Record Chambers Truss Inc. Drawing Name: 75580 SCALE: 1/4" = V-011 291 total trusses, 65 unique designs Designer: BLW Reviewed by: Date: 11/13/18 FOR Sion Homes DESCRIPTION: ACQUAVISTA LOT #3 Page 3 of 3 CUSTOMER INITIALS EACH PAGE 75580