Loading...
HomeMy WebLinkAboutPRODUCT APPROVAL METAL ROOFINGPARTMONT OF ss & Professional Requlatit%n, IPR 1) IVIS IoNs Q=AcT ospit I Foida Approval lic User aopr -P-,ro,-1v, P.L' � =, ProduELApgMyal Menu > Product or AD lication Search > App > Applicotion Detail FL # Application Type Code Version Application Status Comments Archived FL17022-R7 Revision 2017 Approved 08/18/2017v. date reapply 08/21/17 Product Manufacturer Extreme Metal Fabricators, LLC Address/Phone/Email 2160 SW Poma Drive Palm City, FL 34990 (772) 872-8034 fivalidation@yahoo.com Authorized Signature Richard McKuhen fivalidation@yahoo.com Technical Representative Richard McKuhen Address/Phone/Email 2160 SW Poma Drive Palm City, FL 34990 (772) 872-8034 richard@emfab.net Quality Assurance Representative Address/Phone/Email Category Roofing Subcategory Metal Roofing FRECEIV7ED A PD 0 A 'njo APR 2 4 2`018 ST. Lucie County, Permitting Compliance Method Evaluation Report from a Florida Registered Architect or a Licensed Florida Professional Engineer Evaluation Report - Hardcopy Received Florida Engineer or Architect Name who developed the LOCKE BOWDEN Evaluation Report Florida License PE-49704 Quality Assurance Entity Keystone Certifications, Inc. Quality Assurance Contract Expiration Date 04/22/2024 Validated By Zachary R. Priest, P.E. Re Validation Checklist - Hardcopy Received Certificate of Independence Referenced Standard and Year (of Standard) Equivalence of Produ,ct Standards Certified By Sections from the Code FL17022 R7 COI FL17022.1 5V CRIMP ssr.pdf Standard Year TAS 125 2003 UL 1897 2012 UL 580 2006 FILE COPY Product Approval Method Date Submitted Date Validated Date Pending FBC Approval Date Approved Summary of Products Method 1 Option D I 108/18/2017 08/25/2017 08/28/2017 10/10/2017 FL I Model, Number or Name Description 17022.1 1 - "5V Crimp" (116) i 26 Gauge steel, 3/8" rib height, 24" wide lapped roof panel mechanically attached to 15/32" plywood or Wood Deck with fasteners Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: No Installation Instructions FL17022 R7 11 FL 17022.1 5 V CRIMP ssr.pd Verified By: Locke Bowden, P.E. 49704 Created by Independent Third Party: Yes Design Pressure: +N/A/ -Table A Other: Refer to evaluation report for conditions'! Install the Evaluation Reports FL17022 R7 AE FL 17022.1 5 V CRIMP ssr.pdf assembly in compliance with the installation method listed in Created by Independent Third Party: Yes this report and applicable code sections of FBC. Refer to manufacturer's installation instructions. 17022.2 2 - "5V Crimp" (R6) 0.032" Aluminum, 3/8" Rib height, 21" wide lapped roof panel, mechanically attached to 15/32" plywood or Wood Deck with exposed fasteners Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: No installation Instructions FL17022 R7 II FL 17022.2 5 V CRIMP 0.032 ALUM ssr.pff Verified By: Locke Bowden, P.E. 49704 Created by Independent Third Party: Yes Design Pressure: +N/A/ -Table A Other: Refer to evaluation report for conditi6ns.Install the Evaluation Reports FL17022 R7 AE FL 17022.2 5 V CRIMP 0,032 ALUM ssr.p-df Created by Independent Third Party: Yes assembly in compliance with the installation inethod listed in this report and applicable code sections of FBC. Refer to manufacturer's installation i,nstructions. 17022.3 3 "1.5" Mechani�al Seam" (115) 1.5" rib height, 16" wide, 24 gauge steel, standing seam roof panel mechanically attached to 15/32" plywood or wood deck with clips and fasteners. Limits of Use Approved for use in HVHZ: No Installation Instructions FL17022 R7 II FL 17022.3 1.5 MECHANICAL Approved for use outside HVHZ: Yes Impact Resistant: No Design Pressure: +N/A/ -Table A seam 24 a ssr.pdf Verified By: Locke Bowden, P.E. 49704 Created by Independent Third Party: Yes Other: Refer to evaluation report for conditions and Evaluation Reports limitations of use. Install the assembly in.compliance with the FL17022 R7 AE FL 17022.3 1.5 MECHANICAL installation method listed in this report and applicable code sections of FBC. Refer to manufacturer's Installation seam 24 a ssr.pdf Created by Independent Third Party: Yes instructions. I I 17022.4 4 - "1.5" Mecl�anical Seam" (R5) 1.5" rib height, 16" wide, 0.032" aluminum, standing seam roof panel mechanically attached to 15/32" plywood or Wood Deck with clips and fasteners. Limits of Use Installation Instructions Approved for use in HVHZ: No FL17022 R7 11 FL 17022-4 MEC ANCIAL SEAM Approved for use outside HVHZ: Yes ALUMINUM ssr.of Impact Resistant: No Verified By: Locke Bowden, P.E. 49704 Design Pressure: +N/A/ -Table A Created by Independent Third Party: Yes Other: Refer to evaluation report for.'conditions and Evaluation Reports limitations of use. Install the assembly in compliance with the FL17 22 R7 AE FL 17022.4 MECHANCIAL SEAM installation method listed in this repo�t and applicable code ALUMINUM ssr,od sections of FBC. Refer to manufacturelr's installation Created by Independent Third Party: Yes instructions. I I I 17022.5 5 - % in. Nail Strip" (115) 1" rib height, 16" wide, 26 gauge steel, standing seam roof panel mechanically attached to 15/32" plywood or wood deck with fasteners. Limits of Use Installation Instructions Approved for use in HVHZ: No FL17022 R7 11 FL 17022.5 1.0 NAILSTRIP ssr.pd Approved for use outside HVHZ: Yes Verified By: Locke Bowden, P.E. 49704 impact Resistant: No I Created by Independent Third Party: Yes Design Pressure: +N/A/ -Table Evaluation Reports Product Report Manufacturer: Extreme Metal Fabricator! 2160 SW Porr?7 Palm City, FL 34990 (772)872-8034 Compliant with Florida Building Code 2017 (Whed.) Compliant with Florida Product Approval Rule 4 611320-3 Compliant: Keystone Certifications Fastener 1 (Method 1 Attachment): #9 x 1-10" Hex -Washer Head wood screw* to penetrate 3/16" min. thru deck or 5/8" embedment into wood plank. (*or sufficient length to meet requirements) Fastener 2 (Method 2,3, & 4 Attachment): #10 x 1-1/2" Hex -Washer Head wood screw* to penetrate 3/16" min. thru deck or 5/8" embedment into wood plank. (*or sufficient length to meet requirements) Underlayment: To be compliant with FBC Set. Chart 1507.1.1 Slope: Shall be in compliance with FBC Sec. 1,507. See Fastener attachment specificalions above METHOD 2 METHOD 3 METHOD 4 -93.5 PSF -102 PSF -228 PSF 16" O.C. 8" O.C. 6" O.C. 12" o.c. 22" o.c. 12" o.c. #20 #10 #10 Reference Data: ARCHITECTURAL TESTING, INC. TSTID#:1527 UL 580-06 & 1897-04" Test Report C05893.01-450-18 05/02/14 Test Report F3366.01-450-18 12/18/15 TAS 125-03 Test Report D05893.02-450-18 07/22/14 *EQUIVALENCY-UL1897-04 is equivalent to teststandard UL 1897-12 *Design pressure margin ofsafW 2.1 Locke Bowden, P.E. does not have, not will acquire a financial in% a 4��n.?%Nfacturing or distributing products under this evaluation. S Locke Bowden, P.E. is not owned, operated, or controlled by ally cosAparNornbiiafa&tur;o, orSistributing products under this report. /7 R ID FL17022.1 6V Crimp (26GA Steel), 24" Wide Roof Pandi- Details 1. Underlayment to be compliance with current Florida Building Qbde (FBC)2017 6th ed. 2. Minimum slope to be compliant with Florida Building Code 20111� 6th ed., and per with Manufacturers installation reference. 3. Products are compliant for State of Florida product approval per Rule 61 G20-3. Compliance Method: 1 -13 4. Engineering analysis for "project specific approval by local authorities w/jurisdiction is allowed by other registered engineers. 5. Fire classification is not part of this acceptance. Shear diaphragm values are outside this report. 6. Support framing in compliance w/FBC 2017 6th ed., Chapter 22 for Steel, Chapter 23 for Wood and Chapter 16 for Structural Loading. 7. This report does not imply warranty, installation, recommende d,l product use outside of this report. Q, A) — rdblu' lt!"� - #9 .1-1/2" Min! or #10 x . 1-1/2" MI I n. per Table M " for Row 5-V Urnp Roof Panel Spacing and Design Pressures Hex Washer Hbad Wood Screws Deck- 15132" or greater N� or Wood plank —4 247 sir I 1010LSIFUAWNIS--� Nominal 12" Nominal 12" O.C. O.C. fFx- —1-1 /2" Min. or #10 x 1-1 /2" Min. per I Table "A" Hex Washer Head Screw Panel 1 Spaced 12" o.c. across the Panel Width Refer to Table "A" for Spacing Along Panel Overlap Length Dec�- 15/32" or greater I '3';Ood, or W d plank