HomeMy WebLinkAboutENERGY EFFICIENCY CODEFORM R405-2017
FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION
Florida bepartment of Business and Rulbssiu, I al Regulation - Residential Performance Method
Project Name: WYNNE THE GRAND CARLTON Builder Name: WYNNE BUILDING COPR.
:�R 12� rmil� Office: ST. LUCIE COUNTY
Street: 4%_ C Pe
City, State, Zip: FT. PIERCE, FL, �e,&rmit Number:
Owner: WYNNE BUILDING CROP Jurisdiction: ST. LUCIE COUNTY
Design Location: FL, Fort Pierce County:: St. Lucie (Florida Climate Zone 2
1. New construction.or existing
New (From Plans)
9. Wall Types (1442.0 sqft.)
Insulation Area
2. Single family or multiple family
Single-family
oncrete Block - Ext Insul, Exterior
t C
R=4.1 1250.00 ft2
e _
b Fram Nood, Adjacent
R=1 1.0 192.00 ft2
3. Number of units,'if multiple family
I
c. N/A
R= ft2
4. Number of Bedrooms
2
d. N/A
R= ft2
5. Is this a worst case?'
Yes
10. Ceiling Types (1446.0 sqft.)
Insulation Area
a. Under Attic (Vented)
R=30.0 1446.00 ft2
6. Conditioned floor area above grade (ft2)
1446
b. N/A
R= ft2
Conditioned floor area below grade (ft2)
0
c. N/A
R= ft2
1. Ducts
R ft2
7. Windows(141.3 sqft.) Description
Area
a. Sup: Attic, Ret: Attic, AH: Attic
6 325
a. U-Factor: Sgl, U=0.54
101.25 ft2
SHGC: SHGC=0.25
b. U-Factor: SgI, U=0.55
40.00 ft2
Cooling systems
kBtu/hr Efficiency
SHGC: SHGC=0.25
a. Central Unit
34.8 SEER:15.00
c. U-Factor: N/A
ft2
SHGC:
13. Heating systems
kBtu/hr Efficiency
d. U-Factor: N/A
ft2
a. Electric Heat Pump
34.8 HSPF:8.50
SHGC:
Area Weighted Average Overhang Depth:
3.832 ft .
Area Weighted Average SHGC:
0.250
L
14 Hot water systems
Electric
Cap: 40 gallons
8. FloorTypes (1445.5' sqft.)
Insulation Area
EF: 0.970
a. Slab -On -Grade Edge Insulation
R=0.0 1445.50 ft2
b. Conservation features
b. N/A
R= ft2
None
R= ft2
15. Credits
Pstat
Total Proposed Modified
Loads: 48.03
loor Area' 0-.098
Tot I al Baseline
Loads: � 48.08
PASS
I hereby certify tha4 the plans and specifications covered by
this calculation are.in compliance with the Florida Energy
Code. - ------
PREPARED BY- V- - I X.&=lk V A S2XJV-�-kL'_�
DATE: 5,
I hereby certify that thisi building, as designed, is in compliance
with the Florida Erergy�Cocle.
OWNE
DATE:
Review of the plans and
specifi6tions covered by this
calculation indicates compliance
with the' Florida Energy Code'
Before 'construction is completed
this building will be inspected for
complia�ce with Section 553.908
Florida Statutes.
BUILDING OFFICIAL:
DATE: �
- Compliance requires certification by the air handier unit manufacturer
certified factory -sealed in accordance with R403.3.2.1.
- Compliance requires an Air Barrier and Insulation Inspection Checklist
envelope leakage test report with envelope leakage no greater than 7.00
, t%E S
0
7�
0 WF
the air handier enclosure qualifies as
accordance with R402.4.1.1 and this project requires an
'H50 (R402.4.1.2).
4/4/2018 12:13 PM
EnergyGauge@) USA - FlaRes2017 Section R405.�A Compliant Software
Page 1 of 5
FdRM R405-2017
PR I PJECT
Title: WYNNE THE GRAND CARL Bedrooms: 2
Address Type:
Street Address
Building Type: User
Conditioned Are 1446
Lot #
Owner Name: WYNNE BUILDING CROP Total Stories: 1
Block/Subdivision:
# of Units: I
Worst Case: Yes
PlatBook:
Builder Name: WYNNE BUILDING COPR.
Rotate Angle: 180
Street:
Permit Office: ST. LUCIE COUNTY
Cross Ventilation: No
County:
St. Lucie
Jurisdiction: ST. LUCIE COUNTY
Whole House Fan: No
City, State, Zip:
FT. PIERCE,
Family Type: Single-family
FL,
New/Existing: New (From Plans)
Comment:
CLIMATE
V
�Design Temp
Int Design Temp Heating
Design Daily Temp
Design Location
TMY Site 97.5% 2.5%
Winter
Summer Degree Days Moisture
Range
FL, Fort Pierce FL—VERO—BEACH—MUNI 39 90
70
75 299
62
Low
131_061 KS
Number Name
Area Volume
Entire House
1446 11568
SPAC ES
Number Name
Area Volume Kitchen Occupants
Bedrooms
Infil ID Finished Cooled
Heated
I BEDROOM
301 2408 No 0
1
1 Yes
Yes
Yes
2 WIC
63 504 No 0
1 No
Yes
Yes
3 M.BATH
56 448 No 0
1 Yes
Yes
Yes
4 KITCHEN
192 1536 Yes 0
1 No
Yes
Yes
5 BATH
45 360 No 0
1 Yes
Yes
Yes
6 BEDROOM 2
204 1632 No 0
1
1 Yes
Yes
Yes
7 ENTRY
55 440 No 0
1 Yes
Yes
Yes
8 LAUNDRY
42 336 No 0
1 Yes
Yes
Yes
9 GREAT/DINING
488 3904 No 0
1 Yes
Yes
Yes
171_00R�
1
# Floor Type
Space Perimeter Perimeter R-Value
Area
Joist R-Value
Tile Wood
Carpet
1 Slab -On -Grade Edge Insulatio
BEDROOM 52 ft 0
301 ft2
----
0 1
0
2 Slab -On -Grade Edge Insulatio
WIC ift �0
63 ft2
----
0 1
0
3 Slab -On -Grade Edge Insulatio
M.BATH 8ft b
56 ft2
----
0 1
0
4Slab-On-Grade Edge Insulatio
KITCHEN 1 ft 0
192 ft2
----
0 1
0
5 Slab -On -Grade Edge Insulatio
BATH 5ft 0
45 ft2
----
0 1
0
6 Slab -On -Grade Edge Insulatio
BEDROOM 2 32.2 ft 0
203.5 ft2
----
0 1
0
7Slab-On-.Grade Edge Insulatio
ENTRY 7ft 0�
55 ft2
----
0 1
0
414/2018 12:13 PM
EnergyGauge@ USA - FlaRes2017 Section
R405.4.1 Compliant Software
Page 2 of 5
FORM R405-2017
F�100RS
# Floor Type Space Perimeter I Perimeter R-Value
Area
Joist R-Value
Tile
Wood Carpet
8 Slab -On -Grade Edge Insulatio LAUNDRY 6ft
0
42 ft2
----
0
1
0
9 Slab -On -Grade Edge Insulatio GREAT/DINING 46 ft 0
488 ft2
----
0
1
0
R60F
Roof
Galble
Roof
Solar SA
Emitt
Emitt
Deck
Pitch
# Type Materials Area
Alrea
Color
Absor.
Tested
Tested
Insul.
(deg)
1 Gable or Shed Metal 1524 ft2
240 TV
Ught
0.6
No
0.9
No
0
18.4
ATTIC
Type Ventilation
Vent Rlio (1 in)
Area
RBS
IRCC
I Full attic Vented
150
1446 ft2
N
N
CEILI NG
# Ceiling Type Space
R-Valule
Ins Type
Area
Framing Frac Truss Type
I Under Attic (Vented) BEDROOM
30
Blown
301 ft2
0.1
Wood
2 Under Attic (Vented) WIC
30
Blown
63 ft2
0.1
Wood
3 Under Attic (Vented) M.BATH
30
Blown
56 ft2
0.1
Wood
4 Under Attic (Vented) KITCHEN
30
Blown
192 ft2
0.1
Wood
5 Under Attic (Vented) BATH
30
Blown
45 ft2
0.1
Wood
6 Under Attic (Vented) BEDROOM 2
30
Blown
204 ft2
0.1
Wood
7 Under Attic (Vented) ENTRY
30
Blown
55 ft2
0.1
Wood
8 Under Attic (Vented) LAUNDRY
30
Blown
42 ft2
0.1
Wood
9 Uhder Attic (Vented) GREAT/DINING
30
Blown
488 ft2
0.1
Wood
WALLS I
I
Adjacent Cavity Width
�z g nrnt In 1AW1 L4.p,-- Space R--Vallle Ft In
Height
Et In
Are:;
Sheathing Framing
R-NIal-le Eraction
Solar
Ahqnr
Below
Grnrie%
I NE=>SW Exterior Concrete Block - Ext InsdHEDROOM
4.1 10
0 8
0
80.0 ft2
0
0
0.6
0
2 SW=>NE Exterior Concrete Block - Ext Insd9EDROOM
4.1 28
0 8
0
224.0 ft2
0
0
0.6
0
3 NW=>SE Exterior Concrete Block - Ext InsdHEDROOM
4.1 14
0 8
0
112.0 ft2
0
0
0.6
0
4 SW=>NE Exterior Concrete Block - Ext InsulM. BATH
4.1 8
0 8
0
64.0 ft2
0
0
0.6
0
5 NE=>SW Exterior Concrete Block - Ext Insul BATH
4.1 5
0 8
0
40.0 ft2
0
0
0.6
0
6 NE=>SW Exterior Concrete Block - Ext In-QEDROOM 2
4.1 16
0 8
0
128.0 ft2
0
0
0.6
0
7 SE=>NW Exterior Concrete Block - Ext In2KDROOM 2
4.1 10
0 8
0
80.0 ft-
0
0
0.6
0
8 S=>N Exterior Concrete Block - Ext InEREDROOM 2
4.1 4
3 8
0
34.0 ft2
0
0
0.6
0
9 SW=>NE Exterior Concrete Block - Ext InfiEDROOM 2
4.1 2
0 8
0
16.0 ft2
0
0
0.6
0
10 SE=>NW Exterior Concrete Block - Ext Insul ENTRY
4.1 6
0 8
0
48.0 ft2
0
0
0.6
0
11 SW=>NE Exterior Concrete Block - Ext Insul ENTRY
4.1 1 1
0 8
0
8.0 ft2
0
0
0.6
0
12 SW=>NE Exterior Concrete Block - Ext InsaLAUNDRY
1
4.1 6
0 8
0
48.0 ft2
0
0
0.6
0
13 NE=>SW Exterior Concrete Block - Ext InsGREAT/DINI
4.1 26
0 8
0
208.0 ft2
0
0
0.6
0
14 NW=>SE Exterior Concrete Block - Ext InsGREAT/DINI
4.1 20
0 8
0
160.0 ft2
0
0
0.6
0
15 N=>S Gara ge Frame - Wood KITCHEN
11 24
8
192.0 ft2
0.23
0.6
0
4/4/2018 12:13 PM EnergyGaugeO USA - RaRes2017 Section R4b5.4.1 Compliant Software Page 3 of 5
FORM R405-2017
DbORS
# Orn'.t
DoorType
Space Storms U-Value Width
Ft In
Height
Ft In
Area
1 SE=>NW
Insulated
ENTRY None .39 3 1
6 8
20.6 ft2
WINDOWS
Orientation shown is the entered orientation �=>) changed to Worst Case.
Wall
V # Ornt ID Frame
Panes
Overhang
NFRC U-Factor� SHGC Imp Area Depth Separation Int Shade
Screening
1 NW=>SE.3 Metal
2 SW=>NE 4 Metal
3 SE=>NW 7 Metal
4 NE=>SW13 Metal
5 NW=>SE14 Metal
Low-E Single
Low-E Single
Low-E Single
Low-E Single
Low-E Single
Yes 0.54 0.25 N 32.9 ft2 1 ft 0 in 1 ft4 in
Yes 0.54 0.25 N 6.9 ft? 1 ft 0 in 1 ft4 in
Yes 0.54 0.25 N 24.0 ft2 6 ft 0 in 1 ft 4 in
Yes 0.54 0.25 N 37.5 ft2 1 ft 0 in I ft 4 in
Yes 0.55 0.25 N 40.0 ft2 8 ft 0 in 1 ft 4 in
Drapes/blinds
None
None
None
Drapes/blinds
Exterior 5
None
None
None
Exterior 5
GARAGE
# Floor Area
Ceiling Area Exposed Wall Perimeter Avg. Wall Height Exposed Wall Insulation
F-= 1 �15 ft2
315 ft2 24 �ft 8ft
11
INFILTR�TION
# Scope Method
SLA CFM 50 E I LA EqLA ACH ACH 50
1 Wholehouse Proposed ACH(50) .000356
1349.6 74�09 139.34 .2598
7
HEATING S�STEM
System Type
Subtype Efficiency Capacity
Block
Ducts
I El 4ctric Heat Pump/
Split HSPF:8.5 34.8 kBtu/hr
I
sys#1
COOLING SYSTEM
1-7- # System Type
Subtype Efficiency Capacity Air Flow
SHR Block
Ducts
1 Central Unit/
Split SEER: 15 34.8 kBtu/hr cfm
0.8 1
sys#1
HOT WATER SY'STEM
# System Type
SubType
Location EF Use SetPnt
Conservation
I Electric
None
—dap
Garage 0.97 40� gal 60.9 gal 120 deg
None
SOLAR HOT WATER SYSTEM
FSEC
Cert # Company Name
Collector
System Model # Collector Model # Area
Storage
Volume
FEF
None None
ft2
4/4/2018 12:13 PM EnergyGauge@ USA - FlaRes2017 Section R465.4.1 Compliant Software Page 4 of 5
1
FORM R405-2017
DUCTS
Supply
----
---- Return --
Air
CFM 25
CFM25
HVAC #
V/ # 'Location R-Value
Area
Location
Area
Leakage Type
Handler
TOT
OUT
QN
RLF
Heat Cool
1
Attic 6
325 ft2
Attic
85 ft2
Default Leakage
Attic
(Default)
(Default)
1 1
TEMPEkATURES
Prograrnable Thermostat: Y
Ce ing Fans:
Coolin Jan
F:b
M r
Ap r
ay
Jun Jul
AU
ug
Seep
Oct
No
Dec
Heat ng Jan
�X�
F b
M:r
A pr
May
IM
Jun Jul
rj rl
A
rl
�Xl S
�i
Oct
Novv
Dec
Venting Jan
Feb
X Mar
Xj
Apr
May
un Jul
Aug
Sep
Oct
Xi Nov
Dec
Thermostat Schedule:
HERS 2006 Reference
Hours
Schedule Type
1
2
3
4
5 6
7
8
9
10
11
12
Cooling (WD)
AM
78
78
78
78
�78 78
78
78
80
80
80
80
PM
80
80
78
78
8 78
78
78
78
78
78
78
Cooling (WEH)
AM
78
78
78
78
78 78
78
78
78
78
78
78
PM
78
78
78
78
78 78
78
78
78
78
78
78
eat ng D)
AM
66
66
66
66
0b btS
68
68
68
68
68
68
PM
68
68
68
68
6 8 68
68
68
68
68
66
66
Heating (WEH)
AM
66
66
66
66
6 68
68
68
68
68
68
68
PM
68
68
68
68
6 68
68
68
68
68
66
66
4/4/2018 12:13 PM
EnergyGauge(D USA - FlaRes2017 Section
K405.4.1 Compliant Software
Page 5 of 5
2017 - AIR BARRIER AND INSULATION INSPECTI N COMPONENT CRITERIA
I AtSLE 402.4.1.1
AIR BARRIER AND INSULATION INSPECTION COMPONENT CRITERIA
Project.Name: WYNNE THE GRAND CARLTON Builder Name: WYNNE BUILDING COPR.
Street: Permit Office: ST. LUCIE COUNTY
City, State, Zip: FT. PIERCE, FL, Permit Number:
Owner: WYNNE BUILDING CROP Jurisdiction: ST. LUCIE COUNTY
Design Location: FL, Fort Pierce
COMPONENT
AIR BARRIER CRI7rER11
INSULATION INSTALLATION CRITERIA
General
A continuous air barrier shall be installed in the bui ding envelope.
Air -permeable insulation shall
requirements
The exterior thermal envelope contains a continuo s air barrier.
not be used as a sealing material.
Breaks or joints in the air barrier shall be sealed.
The air barrier in any dropped ceiling/soffit shall be a with
gne
Ceiling/attic I
the insulation and any gaps in the air barrier shall be sealed.
I The insulation in any dropped ceiling/soffit
I shall be aligned with the air barrier.
Access openings, drop down stairs or knee wall doo s to
unconditioned attic spaces shall be sealed.
Walls The junction of the foundation and sill plate shall b r1aled.
Cavities within corners and headers of frame walls
The junction of the top plate and the top of exterior`:�w lis shall be
shall be insulated by completely filling the cavity with
sealed.
a material having a thermal resistance of R-3 per inch
Knee walls shall be sealed.
minimum.
Exterior thermal envelope insulation for framed walls
shall be installed in substantial contact and
continuous alignment with the air barrier.
Windows, skylights The space between window/door jambs and framing,
and doors skylights and framing shall be sealed. �d
Rim joists Rim joists shall include the air barrier. Rim joists shall be insulated.
Floors The air barrier shall be installed at any exposed edge oi, Floor framing cavity insulation shall be installed to
(including insulation. i maintain permanent contact with the underside of
above-gara*,e subfloor decking, or floor framing cavity insulation
and cantilevered shall be permitted to be in contact with the top side
floors) i of sheathing, or continuous insulation installed on
the underside of floor framing and extends from the
bottom to the top of all perimeter floor framing
members.
Crawl space walls" Exposed earth in unvented crawl spaces shall be covere� with i, Where provided instead of floor insulation, insulation
a Class I vapor retarder with overlapping joints taped. shall be permanently attached to the crawlspace walls.
Shafcs, penetrations Duct shafts, utility penetrations, and flue shafts opening t
exterior or unconditioned space shall be sealed.
Batts in narrow cavities shall be cut to fit, or narrow
Narrcw cavities cavities shall be filled by insulation that on
installation readily conforms to the available cavity
spaces.
Garage separation Air sealing shall be provided between the garage and conditioned spac as.
Recessed lighting Recessed light fixtures installed in the building thermal enve I lope
Recessed light fixtures installed in the building
shall be sealed to the drywall.
thermal envelope shall be air tight and IC rated.
Plumbing and wiring
Batt insulation shall be cut neatly to fit around wiring
and plumbing in exterior walls, or insulation that on
installation readily conforms to available space shall
'xtend behin pil2ona and wiring
Shower/tub
The air barrier installed at exterior walls adjacent to showers a nd
Exterior walls adjacent to showers and tubs shall
on exterior wall
tubs shall separate them from the showers and tubs.
be insulated.
Electrical/phone box o The air barrier shall be installed behind electrical or communi tion
CP
exterior walls boxes or air -sealed boxes shall be installed.
HVAC register boots
HVAC register boots that penetrate building thermal envelope shall
be sealed to the sub -floor or drywall.
Concealed When required to be sealed, concealed fire sprinklers shall only' be
sprinklers sealed in a manner that is recommended by the manufacturer.
Caulking or other adhesive sealants shall not be used to fill voids
betwe n firpspr'nkler cover plates -and walls or ceilings. I
a. In addition, inspection of log walls shall be in accordance with the provisions of ]CC-400.
4/4/2018 12:13 PIVI EnergyGaugeO USA - FlaRes2017 FBC 6th Edition (?017) Compliant Software Page 1 of I
�ORM R405-2017
ENERGY PERFOR MANCE LEVEL (EPL)
DISPLAY CARD
ESTIMATED ENERGY PE FORMANCE INDEX* = 100
The lower the EnergyPerformancrIndex, the more efficient the home.
I . New construction or existing
2. Single family or multiple family
3. Number of units, if multiple family
4. Number of Bedrooms'
5. Is this a worst cage?
6. Conditioned floor..area (ft')
7. Windows- Description
a. U-Factor: SgI, U=0.54
SHGC: SHGC=0.25
b. U-Factor: SgI, U=0.55
SHGC: SHGC=0.25
c. U-Factor: N/A
SHGC:
d. U-Factor: N/A
SHGC:
Area Weighted Average Overhang Depth:
Area Weighted Average SHGC:
8. Floor Types
a. Slab-On-Grade.Edge Insulation
b. NIA
c. N/A
, FT. PIERCE, FL,
New (From Plans)
Single-family
1
2
Yes
1446
Area
101.25 ft2
40.00 ft2
ft2
ft2
3.832 ft.
0.250
Insulation
Area
R=0.0
1445.50 ft2
R=
ft2
R=
ft2
I certify that this home has complied with the Florida Energy Effic
Construction through the above energy saving features which will
in this home before final inspection. Otherwise, a new EPL Displ�
based on installed Code compliant features.
Builder Signature:
Address of New Home:
9. Wall Types
a. Concrete Block - Ext Insul, Exterior
b. Frame - Wood, Adjacent
c. N/A
d. N/A
10. Ceiling Types
a. Under Attic (Vented)
b. N/A
c. N/A
11. Ducts
a. Sup: Attic, Ret: Attic, AH: Attic
12. Cooling systems
a. Central Unit
13. Heating systems
a. Electric Heat Pump
14. Hot water systems
a. Electric
b. Conservation features
None
15. Credits
Insulation
Area
R=4.1
1250.00 ft2
R=1 1.0
192.00 ft2
R=
ft2
R=
ft2
Insulation
Area
R=30.0
1446.00 ft2
R=
ft2
R=
ft2
R ft2
6 325
kBtu/hr Efficiency
34.8 SEER:15.00
kBtu/hr Efficiency
34.8 HSPF:8.50
Cap: 40 gallons
EF: 0.97
Pstat
icy Code for Building . -fJ4ES
e installed (or exceeded) g 14E S A
-AR
01
Card will be completed S
?LAe)- IT
- rs��N�.
zip.
City/Fl- 46 M121. 00 WE
- --s- -kR -S-1
*Note: This is not a Building Energy Rating. If your Index is below 70, your home may qualify for energy efficient
mortgage (EEM) incentives if you obtain a Florida EnergyGau I ge Rating. Email EnergyGauge tech support at
techsupport(oenergygauge.com or see the EnergyGauge web site at energygauge.com for information and a list of
certified Raters. For information about the Florida Building C de, Energy Conservation, contact the Florida Building
Commission's support staff. I
**Label requi red by Section R303.1.3 of the Florida Building
I Energy Conservation, if not DEFAULT.
4/4/2018 12:13 PM EnergyGauge@ USA - FIaRes2017 - S6ction R405.4.1 Compliant Software Page 1 of I