HomeMy WebLinkAboutTRUSSLumber design values'are,in accordance with ANSI/TPI 1 section 6.3
These truss design's rely on lumber values established by others.
0
MiTek
*�Qgl
RE: M1 1323 - 62'd4nd Carlton III with porch
Site Information:
Customer Info: WYNNNE DEVELOPEMENT CORP
Lot/Block: Subdivisii
Address: N/A
City: PORT ST LUCIE State: FL
Name Address and License # of Structural Engini
Name:
Address:
City:
General Truss Engineering Criteria & Design
Loading Conditions):
Design Code: FBC2017/TPI2014
Wind Code: ASCE 7-10
Roof Load: 37.0 psf
.-'2-
MiTek USA, Inc.
6904 Parke East Blvd.
�Epyl 5ff610-4115
Project Name: M1 1323 Mode
er of Record, If there is one, for the building.
License #: -
State:
(individual Truss Design Drawings Show Special
Design Program: MiTek 20/20 8.1
Wind Speed: 165 mph
Floor Load: N/A psf
This package includes 13 individual, dated TrussiDesign Drawings and 0 Additional Drawings.
With my seal affixed to this sheet, Yhereby certify that I am the Truss Design Engineer and this index sheet
conforms to 61 G1 5-31.003, section 5 of the Florida Board of Professional Engineers Rules.
No.
I S6al#
Truss Name
Date
=
Ti�q��
2/21/18
12
1 T1 33023911
A5
2/21/18 1
13
JT13302392JA6
12/21/18 1
14
JT13302393JA7
(2/21/18 1
15
IT13302394IA8
12/21/18 1
16 1
T1 3302395
1 A9 12/21/18
17 1
T1 3302396
1 GRA 12/21/18
18 __LT1
3302�97
I GR B 12/21/18
J
19 IT13302398IJ2
12/21/18
110 IT13302399IJ4
12/21/18
Ill IT13302400IJ6
12/21/18
112 IT13302401IJ8
12/21/18
113 1
T1 3302402 1
KJ8
2/21/18
The truss drawing(s) referenced above have b&n. prepared by MiTek
USA, Inc. under my direct supervision based on the parameters
provided by Chambers Truss.
Truss Design Engineer's Name: Albani, Thomas
My license renewal date for the state of Florioa is February 28, 2019.
IMPORTANT NOTE: The seal on'these truss
that the engineer named is licensed in the jurisdiction
designs comply with ANSI/TPI 1. These designs are
shown (e.g., loads, supports, dimensions, shapes ani
given to MiTek. Any project specific information inch
file reference purpose only, and was not taken into a(
these designs. MiTek has not independently verifiedi
parameters or the designs for any particular building.'
should verify applicability of design parameters and �
into the overall building design per ANSl/TPl 1, Chaol
,omponent designs is a certification
6) identified and that the
)ased upon parameters
design codes), which were
ded is for MiTek's customers
,ount in the preparation of
he applicability of the design
Before use, the building designer
3perly incorporate these designs
,r 2.
01111111 Ur sit..
... A
N
o 3 0
TATE OF 4U
%
Thomas A. Marl PE No.39380
MlTek USA, Irc. FL Gert 6634
6904 Parke East Blvd. Tampa FL 33610
Date:
February 21,2018
Albani, Thomas 1 of 1
Job
Truss
Truss Type
�ty
Ply
62'Grand Carlton III with porch
T13302390
M11323
A
COMMON
9
_ _
ob ele,ence (optional)
'�7 ; i � ; i — A C n4 4A 4n CQ nn4O D 4
Chambers Truss, inc., Foii Pierce, rL
Z 1 ��' Z U
ID:a3B4Pa,,�r'�'n'Zw'eXyJckSFBgyu�UN-iltlua6G;6.dIn ITrGI?CZC IGrGmYZaVXlillxziuKK
-1 3 12-4-13 17-0-0
21-7-3
L7 43 34-0-0
�11_0040 2_17-i 5_9_0 4-7-3
4-7-3
6-7-13 T-0--ol
Scale 1:57.8
4.00 F1 _2 1 1
4x5
1
6 27
2x3 11 25 2
28 2"3 11
3x6 5
7 3x6
3x4 4
3x4
3
9
24
29
10 It
@
I.A
6
6
17 16 is 30 31
U 13 12
2x3 11 4x6 &B
3x8 4x6 2x3 11 3x6
3x6
12-4-13
21-7-3
L7 4-3 34-0-0
4—
6-7-13 5-9-0 1
9-2-7
>_;_o 6-7-13
Plate Offsets (X,Y)-- f2:0-0-2,Edgel, [10:0-0-2,Edgel
LOADING (psf)
SPACING- 2-0-0
CS1.
DEFL.
in (loc) Vdefl Ud
PLATES GRIP
TCLL 20.0
Plate Grip DOL 1.25
TC 0.39
Vert(LL) 0.32 14-15 >999 360
MT20 244/190
TCDL 7.0
Lumber DOL 1.26
BC 0.68
Vert(CT) -0.61 14-15 >670 240
BCLL 0.0
Rep Stress Incr YES
WB O.,b5
Horz(CT) 0.12 10 n/a n/a
BCDL 10.0
Code FBC20171TPI2014
Matrix -MS
Weight: 163 lb FTn0%
LUMBER-
BRACING-
TOPCHORD 2x4 SP M 30
TOPCHORD
Structural wood sheathing directly applied or 3-7-12 oc puffins.
BOTCHORD 2X4 SP M 30
BOTCHORD
Rigid ceiling directly applied or 4-11-7 oc bracing.
WEBS 2X4 SP No.3
REACTIONS. (lb/size) 2=1362/0-8-0, 10=136210-8-0
Max Horz 2=-1 79(LC 8)
Max Uplift 2=-832(LC 10), 1 0=-832(LC 10)
FORCES. (lb) -Max. Comp./Max. Ten. -All forces 250 (lb) or less except: henshown.
TOPCHORD 2-3=-3419/2395, 3-5=-2771/2031, 5-6=-2770/2152, 6-7=�77012152, 7-9=-2771/2031,
9-10=-3419/2395
BOTCHORD 2-17=-2132/3213,15-17=-2132-/3213,14-15=-1269/2000�il2-14=-2132/3213,
10-12=-2132/3213
WEBS 6-14=-635/983, 7-14=-313/362, 9-14=-689/499, 6-15=-61/983, 5-15=-313/362,
3-15=-689/499 1
NOTES-
1) Unbalanced roof live loads have been considered for this design.
2) Wind: ASCE 7-10; Vult=165mph (3-second gust) Vasd=128Mph; TCDL--4.2pSf; BCDL=3.Opsf; h=14ft; B=52ft; L--34ft; eave=6ft; Cat.
11; Exp C; Encl., GCpi=0.18; MWFRS (directional) and C-C Exterior(2) I L 1 -0-0 to 2-4-13, Interior(l) 2-4-13 to 13-7-3, Exteflor(2) 13-7-3
to 17-0-0, Interlor(l) 20-4-13 to 31-7-3 zone;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate
grip DOL=1.60
3) This truss has been designed for a 10.0 psf bottom chord live load no concurrent with any other live loads.
4) * This truss has been designed for a live load of 20.Opsf on the bottom chord In all areas where a rectangle 3-6-0 tall by 2-0-0 wide
Will fit between the bottom chord and any other members, with BCDL L 1 O.Opsf.
5) Provide mechanical connection (by others) of truss to bearing plate -c, I i'pable of withstanding 100 lb uplift at Joint(s) except at=lb)
2=832,10=832. 1
6) Hanger(s) or other connection device(s) shall be provided sufficient to support concentrated load(s) 50 lb down and 47 lb up at
15-0-0, and 50 lb down and 47 lb up at 19-0-0 on top chord. The design/selection of such connection device(s) Is the responsibility
of others. 1
7) In the LOAD CASE(S) section, loads applied to the face of the truss I 'are noted as front (F) or back (B).
LOAD CASE(S) Standard I
1) Dead + Roof Live (balanced): Lumber Increase=1.' 25, Plate IncreaseL1.25
Uniform Loads (plf)
Vert: 1-6=-54, 6-11 =-54, 18-21 �20
Concentrated Loads (lb)
Vert: 26=-50(F) 27=-50(F)
Thomas A. Albani PE No.39380
MiTek USA, Inc. FL Cert 6634
6904 Parke East Blvd. Tampa FL 33610
Date:
February 21,2018
WARNING -Verify design parameters and READ MOTES ON THIS AND INCLUDEDMiTEKREFERANCE PAGE Mll-7473 rev. IOM312015 BEFORE USE
Design valid for use only with MITek0 connectors. This design Is based only bpon parameters shown. and Is for an Individual building component, not
a it= system. Before use. the buildIng designer must vedfy the applicabilily of design parametets and properly Incorporate this design Into the overall
Bracing Indicated is to buckling Individual truss web andlor chord members only. Addiflonal temporary and permanent bracing
MOW
building design. prevent of
is always required for stability and to prevent collapse with possible perso6al Injury and property damage. For general guidance regarding the
fabricallorr, storage. delivery. erection and bracing of trusses and truss sys ems, seeANSI/TPI I Quality Criteria, DSB-89 and BCSI Building Component
Safety Information available from Iruss Plate Institute, 218 N. Lee Street St. te 312, Plexandfla, VA 22314.
6904 Parke East Blvd.
Tampa, FL 33610
Job
Truss
I Truss Type
qty
Ply
62'Grand Carlton III with porch
T13302391
M 11-.23
A5
SPECIAL
9
1
Job Reference (optional)
a 430
s Se
15 2017 MiTek!ndustries !nc Wed Feb 21 141a:54 201A PAnP I
Chambers Truss, inc.,
ruit riefue, rL
I
r . -1 .
lD-2GIScwwyY5hnGhXVARzUkuyuFUM-BURgnSH4tFldcR2lqTWR6QXpvF)(__HlUfmhlbZNziuKJ
7-8-5
'Tog �� 45
17-0-0
0 8
4, -
34-0-0
-04
VO-0
Oil Voo
7-8-5
6-5-12
�4
82
7-8.0
Scale 1:59.8
4. 0 0 F1_2
5xB I I
2x3 11
2x3 11
5x6 WB--
22
7 3x6
2x3 zz�
4 5
8 3x4
3
21
23
14
10 1110
5x1 2 MT1
8HS
13 12
5x12 2x3 11
Sx6
3X12
2.00 F1 _2
10-6-4
20-4-8
26-4-0
34-0-0
10-6-4
9-10-4
5-11-8
7-8-0
Plate Offsets (X,Y)--
f2:0-1-15, Edge], [4:0-3-0, Edge], f1 0:0-0-6,Edgel i
LOADING (psf)
SPACING-
2-0-0
C St.
�5
DEFL.
In (loc) Well Ud
PLATES
GRIP
TCLL 20.0
Plate Grip DOL
1.25
TC 0.
Vert(LL)
0.76 14 >539 360
MT20
244/190
TCDL 7.0
Lumber DOL
1.25
BC 0A0
Vert(CT)
-1.18 13-14 >344 240
MT18HS
244/190
BCLL 0.0
Rep Stress Incr
YES
WB 0.60
Horz(CT)
0.36 10 n/a n/a
BCDL 10.0
Code FBC2017fTP]2014
Matrix -MS
f
Weight: 155 lb
FT = 0%
LUIMBER- BRACING -
TOP CHORD 2X4 SP M 30 TOPCHORD
BOTCHORD 2X4 SP M 30 BOTCHORD
WEBS 2x4 SP No.3 *Except* WEBS
6-14: 2x4 S P M 30
OTHERS 2x4 SP No.3
REACTIONS. (lb/size) 2=1312/0-8-0, 10=1312/0-8-0
Max Harz 2=-1 79(LC 8)
Max Uplift 2=-803(LC 10), 1 0=-803(LC 10)
FORCES. (lb) -Max. Comp./Max. Ten. -All forces 250 (lb) or less except when shown.
TOPCHORD 2-3=-5529/3776, 3-5=-5164/3538, 5-6=-5209/3667, 6-7=--2 - !424/1902, 7-9=-2462/1813,
9-10=-3195/2210 -14=-1305/2115,12-13=-1948/2995 , 1�10-12=-1948/2995
BOTCHORD 2-14=-3466/5266,13
WEBS 3-14=-355/314, 5-14=-293/354, 6-14=-2175/3326, 6-13=-279/534, 7-13=-237/277,
9-13=-786/560, 9-12=0/269 1
Structural wood sheathing directly applied or 1-7-8 oc puffins.
Rigid ceiling directly applied or 3-9-12 oc bracing.
1 Row at midpt 6-14
NOTES-
1) Unbalanced roof live loads have been considered for this design.
2) Wind: ASCE 7-10; Vult=165mph (3-second gust) Vasd=128mph; T D 2pst, BCD L=3.0psf; h=1 4ft; B=52ft; L:�:3411; eave=6ft; Cat.
C I
11; Exp C; Encl., GCpi=O.l 8; MWFRS (directional) and C-C Exterion(2) - J-0-0 to 2-4-13, Interior(l) 2-4-13 to 13-7-3, Exterior(2) 13-7-3
to 17-0-0, Interlor(l) 20-6-4 to 31-7-3 zone;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate
grip DOL=1.60
3) All plates are MT20 plates unless otherwise Indicated.
4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
5) * This truss has been designed for a live load of 20.Opsf on the bottom 6hord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide
will fit between the bottom chord and any other members.
6) Bearing at joint(s) 2 considers parallel to grain value using ANSI/TPI 1 jangle to grain formula. Building designer should verify
capacity of bearing surface.
7) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at Joint(s) except at=lb)
2=803,10=803.
Thomas A. Albani PE No.39380
MiTsk USA, Inc. FL Cert 6634
8904 Parke East Blvd. Tampa FL 33610
Date:
February 21,2018
WARNING -Verify desig. parameters and READ NOTES ON THIS AND INCLUDFD MITEKREFERANCE PAGE Mll-7473 rev. 10103)2015 BEFORE USE
Design valid for use onlywith MiTek8connectors. ThIsdesIgn Is based ly u n parameters shown. and Is for an Individual bullding component. not
a truss system. Before use, the building designer must v pplicabill I sign parameters and properly Incorporate this design Into the overall
.dfy lt� de
building design. Bracing Indicated Is to prevent buckling of Individual trussFeb and/or chord members only. Additional temporary and permanent bracing
WeW
Is always required for stability and to prevent collapse wilh possible personai injury and property damage. For general guidance regarding the
fabrication, storage. delivery. erection and bracing of trusses and truss systems. seeANSI/IPII Quality Criteria, DSB-69 and BCSI Building Component
6904 Parke East Blvd.
Safety Information available from Truss Plate Institute, 218 N. Lee Street Sultd 312, Mexandfla. VA 22314.
Tampa, FL 33610
Job
Truss
Truss Type
9ty
Ply
62'Grand Carlton III with porch
T13302392
M 11 �',423
AB
SPECIAL
1
Job Reference (optional)
unamDers truss, Inc., t-on merce, I- -I_
2
6
4.00 FIT 6�8
2x3 -Z�,
5x6 WB��
34
21
W2 ;z 2.00 F1 _2
14
5x12 MT1 BHS
?5.1,5v 5 0ep I OZU I I lvll I er, I nuubli let" 111U. VVeu reu � I 14� I U;00 eu I o rdye I
ID:2GIScwwyY5hnGhXVARzUkuyuFUM-fh 3?olieYtUEbdENAlgfd4?AftlOQoo-Lns6qzjuKI
�4 8 25-11-15 34-0-0 so
'8 0-0 1 0 Wo
Y-� _0 L2 5-7-7 8-0-1
5x6
6
13 ------- W-1
3x4 ZZ 12
5x6 =
3x4 --
5X6 WB::z7
7 8
22
Scale = 1:61.9
9 10 U)
17 C?
0
3X6
10-6-4
0
22
��O� 8
25-11-15
34-0-0
10-6-4
i ffl-
4-4
5-7-7
8-0-1
Plate Offsets (X,Y)--
f2:0-1-15, Edge], [3:0-3-0,Edgel, [5:0-4-0,0-2-31,17:0-2-7,lEdgel, [9:0-0-6,Edgel
LOADING (psf)
SPACING- 2-0-0
CS1. I
DEFL.
in (too) I/dell
Ud
PLATES
GRIP
TCLL 20.0
Plate Grip DOL 1.25
TO 0.81
Vert(LL)
0.69 14 >590
360
MT20
244/190
TCDL 7.0
Lumber DOL 1.25
BC 0.63
Vert(CT)
-0.92 14-17 >443
240
MT18HS
244/190
BOLL 0.0
Rep Stress Incr YES
WB 0.66
Horz(CT)
0.34 9 n/a
n/a
BCDL 10.0
Code FBC2017/TP12014
Matrix -MS
I
Weight: 157 lb
FT � 0%
LUMBER-
TOPCHORD
2X4 SP M 30 -Except'
3-6,6-7: 2x4 S P M 31
BOTCHORD
2x4 SP M 30
WEBS
2x4 SP No.3 *Except*
5-14: 2x4 S P M 30
OTHERS
2x4 SP No.3
REACTIONS. (lb/size) 2=1312/0-8-0, 9=1312/0-8-0
Max Horz 2=-1 69(LC 8)
Max Uplift 2=-803(LC 10), 9=-803(LC 10)
FORCES. (lb) -Max. Comp./Max. Ten. -All forces 250 (lb) or less except �vhen shown
BRACING-
TOPCHORD Structural wood sheathing directly applied or 2-2-0 oc puffins.
BOTCHORD Rigid ceiling directly applied or 2-2-0 oc bracing.
TOPCHORD 2-4=-549113336, 4-5=-509513071, 5-6=-2314/1551, 6-8=- 398/1533 8-9 -319911981
BOTCHORD 2-14=-3040/5224,13-14=-1 195/2361, 12-13=-1 123/2199,,111-12=-1 �3�/ZIOI,
9-11 =-1 731/3001
WEBS 4-14=-492/513.5-14=-1707/2959,5-13=-405/196,6-13=-il79/522 8 12- 893/660,
8-11 =01303 1
NOTES-
1) Unbalanced roof live loads have been considered for this design.
2) Wind: ASCE 7-10; Vult=165mph (3-second gust) Vasd=128mph; TCDL'i=4.2psf; BCDL=3.Opsf; h=14ft; B=52ft; L=34ft; eave=6ft; Cat.
11; Exp C; Encl., GCpi=0.18; MWFRS (directional) and C-C Exterlor(2) -ti-0-0 to 2-4-13, Interior(l) 2-4-13 to 31-7-3, Exterlor(2) 31-7-3
to 35-0-0 zone;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60
3) Provide adequate drainage to prevent water ponding.
4) All plates are MT20 plates unless otherwise indicated.
5) This truss has been designed for a 10.0 psf bottom chord live load nonlconcurrent with any other live loads.
6) * This truss has been designed for a live load of 20.0psf on the bottom; chord In all areas where a rectangle 3-6-0 tall by 2-0-0 wide
will fit between the bottom chord and any other members. 1
7) Bearing at joint(s) 2 considers parallel to grain value using ANSI/TPI 1 angle to grain formula. Building designer should verify
capacity of bearing surface. 1
8) Provide mechanical connection (by others) of truss to bearing plate c6pable of withstanding 100 lb uplift at JoInt(s) except at=lb)
2=803,9=803. 1
Thomas A. Alban! PE No.39380
MiTek USA, Inc. FL Cert 6634
6904 Parke East Blvd. Tampa FL 33610
Date:
February 21,2018
I
WARNING -Verity design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERANCE PAGE M11-7473 rev. I&ON2015 BEFORE USE
--
Design valid for use only vAth MffekG connectors. This design Is based rameters shown, and Is for an Individual building component. not
a truss system. Before use. The building designer must verify the appliconilylituy rofnirsign parameters and properly Incorporate this design Into the overall
W1,
building design. Bracing Indicated Is to prevent buciding of Individual truss web and/or chord members only. Additional temporary and permanent bracing
MOW
Is always required for stabIlity and to prevent collapse vAfh possible personal Injury and properly damage. For general guidance Fegardtng the
fabfication, storage, delivery. erection and bracing of trusses ancitrusssyst' S. seeANSI/TPI I Quality Criteria, DSB-89 and BCSI Building Component
6904 Parke East Blvd.
Safety Information available from TFUSs Plate Institute. 218 N. Lee street, SulfrAZ Alexandria, VA 22314.
Tampa, FL 33610
Job
Truss
Truss Type
�ty
Ply
62' Grand Carlton I I I with porch
J13302393
M 11,;23
A7
SPECIAL
I
Job Reference (optional)
unamoers I russ, Inc., t-ori t-ierce, M
B-10-10 4-0-0
"10 -1 8-10-10 15_1 _6
.. . — . —Ij , . — , , .." , .. .1— � I .. I .. — . — .— � U�
ID:WSJqpGwaIPpeur6hkgUjG5yuFUL-7tYRC7JLPsOLr[CQxuZvBfcAj3DQIsZXD�W,eG,iuK�
34-0-0 5-0-
8-0-1 �1 _04
Scale 1:60.8
5X8
5X6
4
4.00F1_2
5
2x3
3x4 zZz
3
6
18
19
2
7
8 t2
5xl2MT18HS=
91
6
10
9
5x12
2x3 11
3X6
3xi 2 2.00 F12_
10-6-4 20-4-8
2%.171 15
34-0-0
%�_l
10-6-4 31 6-4-8
8-0-1
Plate Offsets (X,Y)-- f2:0-1-15, Edge], f4:0-4-0,D-2-31, [7:0-0-2, Edgel
LOADING (psf)
SPACING- 2-0-0
CS1.
DIEFL. In
(loc) Well
Lid
PLATES
GRIP
TCLL 20.0
Plate Grip DOL 1.25
TC 0.83
Vert(LL) 0.66
11 >616
360
MT20
244/190
TCDL 7.0
Lumber DOL 1.25
BC 0.60
Vert(CT) -1.10
10-11 >369
240
MT18HS
244/190
BCLL 0.0
Rep Stress Incr YES
WB 0.45
Horz(CT) 0.34
7 n/a
n/a
BCDL 10.0
Code FBC2017fTP12014
MatrIx-M I S
Weight: 147 lb
FT = 0%
LUMBER-
BRACING-
TOPCHORD 20 SP M 30
TOPCHORD
Structural wood
sheathing directly applied or 2-2-0 oc pudins.
BOTCHORD 2X4 SP M 30
BOTCHORD
Rigid ceiling directly applied or 4-0-2 oc bracing.
WEBS 2x4 SID No.3 *Except*
4-11: 2x4 SP M 30
REACTIONS. (lb/size) 2=1312/0-8-0, 7=1312/0-8-0
Max Horz 2=-1 49(LC 8)
Max Uplift 2=-803(LC 10), 7=-803(LC 10)
FORCES. (lb) -Max. Comp./Max. Ten. -All forces 250 (lb) or less except when shown.
TOP CHORD 2-3=-5484/3370, 3-4=-5116/3126, 4-5=-2229/1544, 5-6=-�448/1599, 6-7=-3169/1993
BOTCHORD 2-1 1=-3071/5219, 10-1 1=-1590/2874,9-10=-1738/2968, 7�9=-11738/2968
WEBS 3-1 1=-419/443, 4-1 1=-1466/2647, 4-10=-812/448,5-10=-205/487, 6-10=-785/575,
6-9=0/272
NOTES-
1 ) Unbalanced roof live loads have been considered for this design.
2) Wind: ASCE 7-10; Vult=165mph (3-second gust) Vasd=128mph; TCD
L�=4.2psf; BCDL=3.0psf; h=14ft; B=52ft; L=34ft; eave=6ft; Cat.
11; Exp C; Encl., GCpi=0.18; MWFRS (directional) and C-C Extedor(2) - �_0-0 to 2-4-13, Interior(l) 2-4-13 to 31-7-3, Extedor(2) 31-7-3
to 35-0-0 zone;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60
3) Provide adequate drainage to prevent water pondinj
4) All plates are MT20 plates unless otherwise IndicatEt
5) This truss has been designed for a 10.0 psf bottom rl�ord live load norlLcurrent with any other live loads.
6) * This truss has been designed for a live load of 20.0psf on the bottom ichord In all areas where a rectangle 3-6-0 tall by 2-0-0 wide
will fit between the bottom chord and any other members. 1
7) Bearing at JoInt(s) 2 considers parallel to grain value using ANSIrrPI 11 angle to grain formula. Building designer should verify
capacity of bearing surface. 1
8) Provide mechanical connection (by others) of truss Ito bearing plate capable of withstanding 100 lb uplift at JoInt(s) except at=lb)
2=803,7=803. 1
Thomas A. Albani PE No.39380
MiTek USA, Inc. FL Cert 6634
6904 Parke East Blvd. Tampa FL 33610
Date:
February 21,2018
A WARNING - VarW design parameters andRE4D NOTES ON THIS AND INGUIDEDMITEKREFERANCE PAGE M11-7473 rev. 10103)2015 BEFORE USE,
Design valid for use only with Milek(E) connectors. This design Is based only dpon
parameters shown, and Is for an Individual building component. not
a truss system. Before use, the building designer must vedfy the app4icabfllq
building design. Bracing Indicated Is to buckilng of Individual ffuss�web
of design parameters and properly Incorporate this design Into the overall
and/or chord members only. Additional temporary and permanent bracing
MiTek*
prevent
is always required for stability and to prevent collapse with possible personpi Injury and properly damage. For general guidance regarding the
fabrication. storage, delivery, erection and bracing of trusses and truss systems. seeANSIIWI 1 Quality Criteria, DSB-89 and BCSI Building Component
6904 Parke East Blvd.
Safety Information available from Truss Plate Institute, 218 N. Lee Street Sullie 312, Alexandria, VA 22314.
Tampa, FL 33610
Job
Truss
Truss Type
Qty
Ply
62'Grand Carlton III with porch
T13302394
M11323
A8
SPECIAL
Job Reference (optional)
(;hambers Truss, inc.,
Fort Pierce, FL
S.Iausocp IoMi 1v111uk1nuLiSu.eS,iriC. vveu e �j j�:jv:u c age
ID:WSJqpGwaIPpeur6hkgUjG5yuFUL-b36pQTKzAA8CTvncVb48k29LBTZgUMw5SfGFAiziuKG
8-8-4
15-8-4
20-4-8 4-8 2 34-0-0
0� 1 L2
50
�,N___?
M-00
8-8-4
3-8-4
4-8-4 _ 13512 9-3-4
Scale 1:60.6
5X6
2X3 11 SX8 —
3X4
4.00 FIT
4
21
6 22 2x3
2 2x3 Z�-
'Z�'
x3
8
-
C;.
.4
23
23
t2
�20
13
9
10 Ir
17
5x1 2 MT1 8HS
,x12 MT18HS—
C0
6
12 11
5x12 3x4
45
3x12
2.00 FIT
10-64
20-4-8
L2 0 01 34-0-0
10-6-4
9-10-4
1 12-0-0
Plate Offsets (X,Y)--
[2:0-1-15, Edge), [7:0-5-8,0-2-81
1
LOADING (psf)
SPACING-
2-0-0
CS1. i
DEFL. in (loc) I/clefl Ud
PLATES
GRIP
TCLL 20.0
Plate Grip DOL
1.25
TC O.T8
Vert(LL) 0.65 12-13 >624 360
MT20
244/190
TCDL 7.0
Lumber DOL
1.25
BC 0.90
Vert(CT) -1.08 12-13 >379 240
MT18HS
244/190
BCLL 0.0
Rep Stress Incr
YES
WB 0.69
Horz(CT) 0.33 9 n/a n/a
BCDL 10.0
Code FBC2017/TP12014
Matrix -MP
Weight: 154 lb
FT = 0%
LIUMBER-
BRACING -
TOP CHORD 2x4 SP M 30
TOP CHORD Structural wood sheathing directly applied or 2-2-0 oc pudins.
BOT CHORD 2x4 SP M 30
BOTCHORD Rigid ceiling directly applied or 3-11 -11 oc bracing.
WEBS 2x4 SP No.3
REACTIONS. (lb/size) 2�1312/0-8-0,9=1312/0-8-0
Max Horz 2=-1 29(LC 8)
Max Uplift 2=-803(LC 10), 9=-803(LC 10)
FORCES. (lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except w . hen shown.
TOPCHORD 2-3=-5488/3444, 3-4=-5117/3183, 4-5=-3911/2497, 5-6=-1 1 57611770, 6-7=-2586/1779,
7-8=-2663/1762, 8-9=-3021/1971
BOTCHORD 2-13=-314315224,12-13=-195613292, 11-12=-1369/2481,,9-11=-1705/2827
WEBS 3-13=-396/420, 4-13=-1028/1721, 5-13=-300/797, 5-12=-894/601, 6-12=-2651263,
7-12=-294/391, 7-11=-374/691, 8-11=-535/502 1
NOTES-
1) Unbalanced roof live loads have been considered for this des!
2) Wind: ASCE 7-10; Vult=165mph (3-second gust) Vasc1=128mgn: TCDL--4.2psf; BCDL=3.Opsf; h=14ft; B=52ft; L--34ft; eave=6ft; Cat.
11; Exp C; Encl., GCpi--0.18; MWFRS (directional) and C-C Exterlor(2) )-0-0 to 2-4-13, Interlor(l) 2-4-13 to 31-7-3, Exterior(2) 31-7-3
to 35-0-0 zone;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60
3) Provide adequate drainage to prevent water poncling.
4) All plates are MT20 plates unless otherwise Indicated.
5) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
6) * This truss has been designed for a live load of 20.Opsf on the bottoml chord In all areas where a rectangle 3-6-0 tall by 2-0-0 wide
will fit between the bottom chord and any other members.
7) Bearing at Joint(s) 2 considers parallel to grain value using ANSI/TPI I angle to grain formula. Building designer should verify
capacity of bearing surface. i
8) Provide mechanical connection (by others) of trus§ to bearing plate capable of withstanding 100 lb uplift at Joint(s) except Gt=lb)
2=803,9--803. 1
Thomas A. Albani PE No.39380
MiTak USA, Inc. FIL Cart 6634
6904 Parke East Blvd. Tampa FL 33610
Date:
February 21,2018
,&WARNING -Vedly design parameters and READ NOTES Off THIS AND IAlCLUD'EDMfTEKREFERANCE PAGE M/1-7473 rev. 10,03J2015 BEFORE USE
Design valid for use only vAlh MffekO connectors. This design is based orgy dpon parameters shown, and Is for an Individual building component. riot
a truss system. Before use, the building designer must verify the applicability. , of design parameters and properly Incorporate this design Into the overall
building design. Bracing Indicated Is to prevent buckling of Individual truss �veb and/or chord members only. Addlifional temporary and permanent bracing
MOW
Is always required for stability and to prevent collapse with possible personol Injury and property damage. For general guidance regardng the
fabrIcallort storage. delivery, erection and bracing of trusses and truss syst,�ms, seeANSI/TPI I Quality Criteria, DSB-89 and BCSI Building Component
6904 Parke East Blvd.
Safety Information available from Taw Plate Institute. 218 N. Lee Street, Suite 312, Alexandria. VA 22314.
Tampa, FL 33610
Job
Truss
Truss Type
qty
Ply
62'Grand Carlton III with porch
T13302395
fvll.�23
Ag
HIP
Job Reference (optional)
(;namt)ers I russ, Inc., t-on: merce, t-L
C�.
6
T-0-0 152- 4
3-TT 9 114
4x4 3x4
10-4-0
D. kou � oup I a — � I Ivil I wn 111-- —, I.-
3ixVV?huls?ypJyuFUK-3FgBdpKbwTG353Mp3JbNGGidcs?ZDm3EgJ?oiI
1 �4
3�0-0 �7 4-11 34-0-0 5-
6-7-15 ?1_0
2x3 11 48 =
LOADING (pst)
S ACING-
2-0-0
CS1.
I
DEFL.
In (loc)
I/defl
Ud
TOLL 20.0
Plate Grip DOL
1.25
TO
0.35
Vert(LL)
-0.18 11-21
>917
360
TCDL 7.0
Lumber DOL
1.25
BC
Oj54
Vett(CT)
-0.38 11-21
>432
240
BOLL 0.0
Rep Stress Incr
YES
WB
0189
Horz(CT)
0.02 13
n1a
n/a
BCDL 10.0
Code FBC2017/TPI2014
Matrix -MS
LIUMBER- BRACING-
TOPCHORD 2X4 SP M 30 TOPCHORD
BOTCHORD 2X4 SP M 30 BOTCHORD
WEBS 2x4 SP No.3
REACTIONS. (lb/size) 2m663/0-8-0.9=346/0-8-0,13=1616/0-8-0
Max Harz 2=1 09(LC 9)
Max Uplift 2=-430(LC 10), 9=-249(LC 10), 13=-928(LC 10)
Max Grav 2=685(LC 19), 9=386(LC 20), 13=1 616(LC 1)
FORCES. (lb) -Max. Comp./Max. Ten. -All forces 250 (lb) or less except when shown.
TOPCHORD 2-3=-1275/1025,3-4=-913f7O8,4-5=-829/705,5-6=-565/ 0 6-7=-565/807,
7-8=-104/278, 8-9=-341/235
BOTCHORD 2-15=-836/1187,13-15=-34/309,11-13=-256/348 9-11J124/304
WEBS 3-15=-425/50115-15=-444/665,5-13=_1215/1079:6-13—'-264/300,7-11=-255/396,
8-11 =-461/521, 7-1 3=-8371703
NOTES-
1 ) Unbalanced roof live loads have been considered for this design.
2) Wind: ASCE 7-10; Vult=165mph (3-second gust) Vasd=128mph; T
11; Exp C; Encl., GCpi=0.18; MWFRS (directional) and C-C Exterior
10-0-0, Interior(l) 14-9-11 to 19-2-5, Exterior(2) 24-0-0 to 35-0-0 zo
Lumber DOL=1.60 plate grip DOL"-1.60
3) Provide adequate drainage to prevent water ponding.
4) This truss has been designed for a 10.0 psf bottom chord live load
5) * This truss has been designed for a live load of 20.Opsf on the bott
will fit between the bottom chord and any other members.
6) Provide mechanical connection (by others) of truss to bearing plate
2=43019=249,13=928.
Scale = 1:58.6
PLATES GRIP
MT20 244/190
Weight: 156 lb FT=0%
Structural wood sheathing directly applied or 5-11-9 oc purlins.
Rigid ceiling directly applied or 6-0-0 oc bracing.
L=4.2psf; BCDL=3.Opsf; h=14ft; B=52ft; L=34ft; eave=6ft; Cat.
-1-0-0 to 2-4-13, Interior(l) 2-4-13 to 5-2-5, Extedor(2) 5-2-5 to
C-C for members and forces & MWFRS for reactions shown;
concurrent with any other live loads.
chord In all areas where a rectangle 3-6-0 tall by 2-0-0 wide
of withstanding 100 lb uplift at joint(s) except at=lb)
t2
�L
C6
0 �2
16
6
Thomas A. Albani PE No.39380
MiTek USA, Inc. FL Cart 6634
6904 Parke East Blvd. Tampa FL 33610
Date:
February 21,2018
,& WARAllt[G- Verily design parameters and READ NOTES ON THIS AND INCiUDEDMirEKREFERANCE PAGE Mll-7473 rev. 1010312015 BEFORE USE.
Design valid for use only with MITek0 connectors. This design is based oni� upon parameters shown, and Is for an Individual building component not
a truss system. Before use, the building designer must verify the applicability of design parameters and properly Incorporate this design Into the overall
building design. Bracing Indicated Is to prevent buckling of Individual truss web and/or chord members only. Additional temporary and permanent bracing
MiTele
Is always required for stability and to prevent collapse with possible pers�nal injury and property damage. For general guidance regarding the
fabilcation, storage. delivery, erection and bracing of trumes and truss systems, seeANSI/TPI 1 Quality Criteria, DSB-89 and SCSI Building Component
6904 Parke East Blvd.
Safety Information available from TRm Plate Institute, 218 N. Lee Street, Suite 312, Mexandfia, VA 22314.
Tampa, FIL 33610
Job
Truss
Truss Type
City
Ply
62'Grand Carlton III with porch
T13302396
M11323
GRA
HIP
I
1
1
�
Job Reference (optional)
Chambers Truss, Inc., Fort Pierce, FL u. i 3u s Sep i o 20i 7 Miii ek indusirie5, inc. vveu reu 2 i i -t; i ��5G 40 i a ruy� i
I ID:_etClcxC3ixVV?huls?ypJyuFUK-XSEZqgLDhnOwiD)O. c06cpTEfaGKGyBpOvzlMFbziuKE
8-0-0 17-0-Of IL8 6 01 2 22 0 34-0-0 0-?
B-0-0 5-10-15 1 -0 --
4-0-0-0 -0 0
3 8
TOP CHORD MUST BE BRACED BY END JACKS, Scale 1:60.6
ROOF DIAPHRAGM, OR PROPERLY CONNECTED
PURLINS AS SPECIFIED.
6
3x5 3.6 11 : 6X8 3x6 = 6X8 4x4
6x8 i
3 t2
4
0
Plate Offsets (X,Y)-- [2:0-2-2,Edgel, [3:0-3-8,Edgel, [21:0-3-8,Edgel, [24:0-0-8,0-3-01, f27:0-3-8,0-3-0]
LOADING (psf)
SPACING- 2-0-0
CS1. I
DEFL. in (too) I/defl Ud
PLATES GRIP
TCLL 20.0
Plate Grip DOL 1.25
TC 0.91
Vert(LL) 0.20 24-35 >914 360
MT20 244/190
TCDL 7�O
Lumber DOL 1.25
BC b.57
Vert(CT) -0.24 29-32 >552 240
BCLI- 0.0
Rep Stress [nor NO
I
WB 1 0 1 98
Horz(CT) 0.02 22 Na n/a
BCDL 10.0
Code FBC2017rrP[2014
MatrlxrMS
Weight: 194 lb FT = 0%
LUMBER-
BRACING -
TOP CHORD 2X4 SP M 30
TOPCHORD Structural wood sheathing directly applied or 4-2-5 oc puffins.
BOT CHORD 2x4 SP M 30
Except:
WEBS .2x4 SP No.3
1 Row at mIdpt 8-21
BOTCHORD Rigid ceiling directly applied or 6-0-0 oc bracing.
JOINTS 1 Brace at Jt(s): 7, 8, 19,17,14
REACTIONS. All bearings 0-8-0.
Qb) - Max Horz 2=-1 79(LC 6)
MaxUpllft All uplift 100 lb or less atjoint(s) except 2=-351(l-C 8). 27=-1168(LC 8), 26=-1495(LC 8),
22=-625(LO 8)
1
MaxGrav All reactions 250 lb or less at joint(s) except 2=487(LC 17), 27=2232(LC 13), 26=2929(LC 14),
22=984(LC 14)
1
FORCES. (lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown.
TOPCHORD 2-�3=-621/387, 3-5=-304/838, 5-7=-588/1209, 7-8=-58811209, 8-12=-588/1209,
12-13=-588/1209,13-15=-688/1209,15-16=-588/1209,16-18=-q88/1209,
18-20=-2230/1280,20-21=-2230/12EI0, 21-22=-2271/i263,6-9=-l26/305, 9-1 1=-106/363,
11-14=-193/412,14-17=-94/271,19-�21- 143/272 1
BOTCHORD 2-29=-247/677, 27-29m-189/540, 26-',27=:779/446, 2416=411/653, 22-24=-1083/2108
WEBS 3-29=-500/1176, 3-27=-1766/911, 5-27=-748/622, 5-26=-546/351, 13-26=-946/617,
18-26=-2412/1474,18-24=-846/1780,21-24=-35/35 4-5=-608/514,19-20=-335/305,
14-15=-556/407,11-12=-254/54 I
NOTES-
1) Unbalanced roof live loads have been considered for this design. 1
2) Wind: ASIDE 7-10; Vult=165mph (3-second gust) Vasd=128mph; TCDL=4.2psf; BCDL=3.opsf; h=14ft; B=52ft; L=3411t; eave=6ft; Cat.
11; Exp C; Encl., GCpl=O.l 8; MWFRS (directional); Lumber DOL=J .60 plate grip DOL=1.60
3) Provide adequate drainage to prevent water ponding.
4) All plates are 2x3 MT20 unless otherwise indicated.
5) This truss has been designed for a 10.0 psf bottom chord live loa I d nonconcurrent with any other I Ive loads.
6) * This truss has been designed for a live load of 20.Opsf on the b I ottorn chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide
will fit between the bottom chord and any other members. 1
7) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 351 lb uplift at joint 2, 116B lb uplift at
joint 27, 1495 lb uplift at joint 26 and 625 lb uplift at joint 22.
8) Girder carries hip end with 8-0-0 end setback.
9) Graphical pudin representation does not depict the size or the onentation of the purlin along the top and/or bottom chord.
10) Hanger(s) or other connection device(s) shall be provided sufficient to support concentrated load(s) 967 lb down and 461 lb up at
26-0-b, and 967 lb down and 461 lb up at B-0-0 on bottom chord. The design/selection of such connection device(s) is the
responsibility of others. 11
11) In the LOAD CASE(S) section, loads applied to If W faVV VJ Ll 1� Ll un are noted as front (F) or back (B).
I
Thomas A. Albani PE No.39380
MiTek USA, Inc. FIL Cert 6634
8904 Parke East Blvd. Tampa Fl. 33610
Date:
February 21,2018
,& WARNING- Verify design parameters and READ NOTES ON THISAND iNCLUDED MITEKREFERANCE PAGE M11-7473 rev. 1010=015BEFORE USE.
Design valid foruse onlywith MITek9 connectors. ThIsclesign tsbasc�onlyupon parameters shown. andisforan Individual building component. not
a truss system. Before use. the building designer must verify the applicability of design parameters and properly Incorporate this design Into the overall
building design. Bracing Indicated Is to prevent buckling of Individual truss web and/or chord members only. Additional temporary and permanent bracing
WeW
Is always required for stability and to prevent collapse with possible personal Injury and property damage. For general guidance regarding the
fabrication. storage. delivery. erection and bracing of trusses and truss systems. seeANSI/TPI 1 Quality Criteria, DSB-89 and BCSI Building Component
6904 Parke East Blvd.
Safety Information available from Truss Plate Institute. 218 N. Lee Str6et, Suite 312. Alexandria. VA 22314.
Tampa, FL 33610
Job
russ
Truss Typ
1�ty
Ply
62'Grand Carlt n III with porch
T13302396
M11323
GRA
HIP
1
1
Job Reference (optional)
Chambers Truss, Inc., Fort Pierce, I'L
ts.i;jus oep io eui / MaTeK MdUbuleb, jriL;. VVWu r1VU e i i-to i�.Du ev 10 rayv C
ID:—etClcxC3ixVV?huls?ypJyuFUK-XSEZq9LDhnOwiDx?co6cpTEfaGKGyBpOvz[MFbziuKE
LOAD CASE(S) Standard
1) Dead + Roof Live (balanced): Lumber Increase=1.25, Plate Increase=1.25
Uniform Loads (pit)
Vert: 1-3=-54, 21-23=-54, 29-30=-20, 24-29=-47(F=-27), 24-33=-20, 3-11,=-126(F=-72), 11-21=-126(F=-72)
Concentrated Loads (lb)
Vert: 29=-641 (F) 24=-641 (F)
WARNING- Verify design paraind.. and READ iVOTES ON THIS AND MCLUDED MITEK REFERANCE PAGE MlIP7473 rev. 1010312015 BEFORE USE.
Design valid for use only with MiTekO connectors. This design is based ohy upon parameters shown. and Is for an Individual bugdlng component. not
a Iruss; system. Before use, the building designer must verify the appucabuity, of design parameters and properly Incorporate this design Into the overall
building design. Bracing Indicated Is to prevent buckling of Individual Iruss web and/or chord members only. Additional temporary and permanent bracing
MiTeW
Isalways requIred for stability and to prevent collapse with possible personal Injury and property damage. For general guidance regardlng the
fabilcatiom storage. delivery, erection and bracing of frusses and 1pissfsystems, seeANS 17PIl Quality Criteria, DSB-89 and BCSI Building Component
6904 Parke East Blvd.
Safety Information avallable from Truss; Plate Institute. 218 N. Lee Street, Suite 312, Maxandfla. VA22314.
Tempe. FL 33610
Job
Truss
Truss Type
oty
Ply
62 ran at I n I I I with porch
T13302397
M11323
GRB
HIP
Job Reference (optional)
Chambers Truss, Inc., Fort Pierce, FL 8.130 s Sep i 5 20i 7 MiTek industries, Inc. Wed Feb 21 14:20:0 1 2018 Page I
ID:SrRaEyyrqO4M78G4raWBLWyuFUJ-TqMKFrNTDOedyW4NkR84uuKlw4_?Q6XhNGETJTziuKC
8-0-0 13-80 700 4 0 600 34-0-0 5-0-
8-0-0 58_ 8-0-0
q140 .3
Scale = 1:58.6
— —1.UC — I WO =
0 !�2
16
6
U6 5xr, SX6 4x6
13-8-0
-40
26-0-0
34-0-0
8-0-0 5-8-0
6-
5-8-0
B-0-0
Plate Offsets (X,Y)-- [3:0-5-4,0-2-81, [5:0-3-0, Edge], [8:0-5-4,0-2-81
LOADING (pst)
SPACING- 2-0-0
CS1.
DEFL.
in (loc) I/defl Lid
PLATES
GRIP
TCLL 20.0
Plate Grip DOL 1.25
TC 0.80
Vert(LL)
0.22 16-19 >999 360
MT20
244/190
TC;DL 7.0
Lumber DOL 1.25
BC 0.68
Vert(CT)
-0.30 16-19 >820 240
MT18HS
244/190
BCLL 0.0
Rep Stress Incr NO
WB .0'.90
Horz(CT)
0.06 9 rVa n/a
BCDL 10.0
Code FBC2017/TP12014
Matrix -,MS
Weight: 153 lb
FT = 0%
LUMBER-
BRACING -
TOP CHORD 2X4 SP M 30
TOPCHORD
Structural wood sheathing directly applied or 3-1-14
oc purlins.
BOTCHORD 2x4 SP M 30
BOTCHORD
Rigid ceiling directly applied or 5-3-14 oc bracing.
WEBS 2x4 SP No.3 *Except*
WEBS
I Row at midpt 3-14,8-13,6-13
4-14,7-13: 2x6 SP No.2
REACTIONS. (lb/size) 2=1269/0-8-0,13=4057/0-8-0,9=474/0-8-0
Max Horz 2=90(LC 7)
Max Uplift 2=-853(LC 8). 13=-2590(LC 8), 9=-345(LC 8)
Max Grav 2=1451(LC 13), 13=4743(LO 15), 9=528(LC 14)
1
FORCES. (lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown.
TOPCHORD 2-3=-3625/1950, 3-4=-208011236, 4-6---2080/1236 ' 6-7--1296/2589, 7-8=-1296/2589,
B-9=-751/370
BOTCHORD 2-16=-172913460,14-16=-1753/3525,11-13=-2621733[9-1 1=-2411668
WEBS 3-16=-435/1209, 3-14=-1 5521774, 4-14--837/691, 7-1 3=-878f713, 8-13=-36351191
9,
8-11 =-432/1204, 6-14=-1 453/2814, 6-13=-3198/1807 1
NOTES-
1 ) Unbalanced roof live loads have been considered for this design.
2) Wind: ASCE 7-10; Vult=165mph (3-second gust) Vasd=128mph; TODL=4.2psf; BCDL=3.Opsf; h=14ft; B=52ft; L=34ft; eave=6ft; Cat.
11; Exp C; Encl., GCpl=0.18; MWFRS (directional); Lumber DOL=1.60 plate grip DOL=1.60
3) Provide adequate drainage to prevent water ponding.
4) All plates are MT20 plates unless otherwise Indicated.
5) This truss has been designed for a 10.0 psf bottom chord live load.nonconcurrent with any other live loads.
6) * This truss has been designed for a live load of 20.Opsf on the bot,tom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide
will fit between the bottom chord and any other members.
7) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 853 lb uplift at joint 2, 2590 lb uplift at
joint 13 and 345 lb uplift at joint 9.
8) Girder carries hip end with 8-0-0 end setback.
9) Hanger(s) or other connection device(s) shall be provided sufficient to support concentrated load(s) 967 Ito down and 461 lb up at
26-0-0, and 967 lb down and 461 . lb up at 8-0-0 on bottom chord., The design/selection of such connection device(s) Is the
responsibility of others. I
10) In the LOAD CAS E(S) section, loads applied to the face of the I I �uss are noted as front (F) or back (B).
LOAD.CASE(S) Standard Thomas A. Alban! PE No.36380
1) Dead + Roof Live (balanced): Lumber Increase=1.25, Plate Incr6ase=1.25
MiTek USA, Inc. FL Cert 6634
Uniform Loads (plf) 6904 Parke East Blvd. Tampa FL 33610
Vert: 1 -3=-54, 3-8=-1 31 (F=-77). 8-1 0=-54, 'I 6-17=-20, 1 1 �1 -1 6=-49(F=-29), 11-20=-20 Date:
February 21,2018
WARNING- Verify design parameters and REW NOTES ON THIS AND INCLUDED WEI(REFERANCE PAGE M11-7473 rev. 10/03)2015 BEFORE USE.
Design valid for use onlywith MiTekO connectors. This design is based �niy upon parameters shown. and Is for an Individual building component not
a truss system. Before use, the building designer must verify the applicability of design parameters and properly Incorporate this design Into the overall
building design. Bracing Indicated Is to prevent buckling of Individual truss web and/or chord members only. Additional temporary and permanent bracing
MiTek*
is always required for stability and to prevent collapse with possible personal Injury and property damage. for general guidance regarding the
fabrIcatlort storage. delivery� erection and bracing of trusses and tnt� . s systems. seeANSI/TPI I Quality Criteria, DSB-89 and BCSI Building Component
6904 Parke East Blvd.
Safety Information available from Truss Plate Institute. 218 N. Lee Streot, Suite 312, Aexandria, VA 22314.
Tampa, FL 33610
Job
Truss
Truss Type
9ty
Ply
Carlton III with porch
T13302397
M`111�23
GREI
HIP
i
,
�62'Grand
Job Reference (optional)
Chambers Truss, Inc., Fort Pierce, FL
LOAD CASE(S) Standard
Concentrated Loads (lb)
Vert: 1 6=-641 (F) 11 =-641 (F)
U30 s Sep i5 2017 MiT ek industries, Inc. vveu rev � i 1�:ev:u 1 40 18 Page
ID:SrRaEyyrqO4M78G4raWBLWyuFUJ-TqMKFrNTDOedyW4NkR84uuKlw4—?Q6XhNGETJTziuKC
,& wARNtNG- verify design parameters and REW NOTES ON THIS AND,11NCLUDEDMffEKREFERANCE PAGE M11-7473 rev. lelo3,2015 BEFORE USE.
for use only with MITek9 connectors. This design Is bas� dy upon parameters shown, and Is for an Individual bullding component. not
Design 0
valid
I cability of design parameters and property Incorporate this design Into the overall
a truss system. Before use, the budiding designer must V, I
building design. Bracing Irsdicated Is to prevent buckling or Individual truss web and/or chord members only. Additional temporary and permanent bracing
MiTek*
Is always required for stability and to prevent collapse with possible personal Injury and property damage. For general guidance regarding the
fabricallom storage. delivery, erection and bracing of trusses and truss system% seeANSI/TPI I Quality Crilerla, DSB-89 and BCSI Building Component
6904 Parke East Blvd.
Safety Information available from Truss Plate Institute. 218 N. Lee Str�et, Suite 312, Aexandrla, VA 22314.
Tampa, Fl- 33610
Job
Truss
Truss Type
aty
Ply
62 rand Carlton III with porch
I .
I
T13302398
M11323
J2
MONO TRUSS
8
1
Job Reference (optional)
L;nalnbers I russ, Inc., I -on Pierce, 1-L Mou 5 oep ioeui i IVII I BK mousines, mc. Yveu rev e i i-+;eu;u i eu io r-age i
ID:xl?zSlzTbJCDIIrGPHiQukyuFUI-TqMKFrNTDOedyW4NkR84uuKBb47aQKfhNGETJTziuKC
-1-0-0 2-0-0
1-0-0 2-0-0
Scale = 1:7.8
LOADING (ps" - )
S ACING- 2-0-0
CS1. i
DEFL.
in
(loc)
I/defl
Ud
PLATES GRIP
TCLL 20.0
Prate GrIp DOL 1.25
TC 0.18
Vert(LL)
-0.00
7
>999
360
MT20 2441190
TCDL 7
Lumber DOL 1.25
Bc 6.07
Vert(CT)
-0.00
7
>999
240
BCLL 0�00
Rap Stress Incr YES
WB 6.00
Horz(CT)
-0.00
3
n/a
n/a
BCDL 10.0
Code FBC2017rrPI2014
Matrix- I MP
Weight: 8 lb FT=O%
LUMBER -
TOP CHORD 2x4 SP No.3
BOT CHORD 2x4 SP No.3
REACTIONS. (lb/size) 3=38/Mechanical,2=141/0-8-0,4=22/Mec
Max Horz 2=67(LC 10)
Max Uplift 3=-28(LC 10). 2=-1 36(LC 10), 4=-3(LC 7)
Max Grav 3=39(LC 15), 2=141 (LC 1), 4=31 (LC 3)
FORCES. (lb) -Max. Comp./Max. Ten. -All forces 250 (lb) or less
NOTES-
1) Wind: ASCE 7-10; Vult=165mph (3-second gust) Vasd=1 28mph; T
11; Exp C; Encl., GCpi=0.18; MWFRS (directional) and C-C Exterior
shown; Lumber DOL=11.60 plate grip DOL=1.60
2) This truss has been designed for a 10.0 psf bottom chord live load
3) * This truss has been designed for a live load of 20.Opsf on the bott
will fit between the bottom chord and any other members.
4) Refer to girder(s) for truss to truss connections.
5) Provide mechanical connection (by others) of truss to bearing plate
2 and 3 lb uplift at joint 4.
BRACING -
TOP CHORD Structural wood sheathing directly applied or 2-0-0 oc pudins.
BOTCHORD Rigid ceiling directly applied or 10-0-0 oc bracing.
whenshown.
L=4.2psf; BCDL=3.Opsf; h=14ft; B=52ft; L=34ft; eave=6ft; Cat.
zone; C-C for members and forces & MWFRS for reactions
concurrent with any other live loads.
chord In all areas where a rectangle 3-6-0 tall by 2-0-0 wide
of withstanding 28 lb uplift atJoInt 3, 136 lb uplift at joint
Thomas A. Albani PE No.39380
MiTak USA, Inc. FL Cart 6634
6904 Parke East Blvd. Tampa FL 33610
Date:
February 21,2018
,& WARNING - Verify design parameters and READ NOTES ON THIS AND IkCLUDED MITEK REFERANCE PAGE M11-7473 rev. 101=015 BEFORE USE
Design valid for use only wilb, MITek@ connectors. This design is based 6niy upon parameters shown. and Is for or) Individual building component, not
a truss system. Before use. the building designer must verity the applicability of design parameters and properly Incorporate this design Into the overall
building design. Bracing Indicated Is to prevent buckling of Individual truss web and/or chord members only. Addillonal temporary and permanent bracing
MiTek*
Is always required for stability and to prevent collapse wilh possible personal Injury and property damage. For general guidance regarding the
fabrication. storage, delivery; erection and bracing of trusses and " systems. seeANSI/TPI I Quality Criteria, DSB-89 and BCSI Building Component
6904 Parke East Blvd.
Safety Information available from Truss Plate Institute, 218 N. Lee Street, Suite 312, AJexcnddcx VA 22314.
Tampa, FIL 33610
Job
Truss
Truss Type
9ty
Ply
62'Grand Carlton III with porch
T1330239
M 11323
J4
MONO TRUSS
8
Job Reference (optional)
Chambers Truss, Inc., Fort Pierce, FL
LOADING (pst)
TCLL 20.0
TCDL 7.0
BCLL 0.0
BCDL 10.0
LUMBER -
TOP CHORD 2x4 SIP No.3
BOT CHORD 2x4 SP No.3
1-0-0
3x4 =
SPACING-
2-0-0
Plate Grip DOL
1.25
Lumber DOL
1.25
Rep Stress Incr
YES
Code FBC2017/TP12014
8. i 30 s Sep i 5 2017 Mi Tek Industries, I ne. vy eu reu 4 j 14:20:02 20 16 F age I
I D: PDYLfd_5MdK4MSQTz?ZfRxyuFU H-y I wiTBN5�_imUZgfal8fJR6s[—UP79nvqbwzOswziuKB
Scale = 1: 11. 1
t 4.00F1_2
CSi. i
DEFL. in (loc) I/defl Ud
PLATES GRIP
'
TC 0.39
Vert(LL) 0.02 4-7 >999 360
MT20 244/190
BC 6.37
Vert(CT) -0.02 4-7 >999 240
WB 0.00
Horz(CT) -0.00 3 n1a n/a
MatrixiMP
Weight: 14 Ib FT = 0%
BRACING -
TOP CHORD Structural wood sheathing directly applied or 4-0-0 oc puflins.
BOTCHORD Rigid ceiling directly applied or 10-0-0 oc bracing.
REACTIONS. (lb/sIze) 3=90/Mechanical,2=207/0-8-0,4=50/MeCl'
Max Horz 2=1 04(LC 10)
Max Uplift 3=-80(LC 10), 2=-161(LC 10), 4=-7(LC 10)
Max Grav 3=90(LC 1), 2=207(LC 1), 4=69(LC 3)
FORCES. (lb) -Max. Comp./Max. Ten. -All forces 250 (lb) or less except when shown.
NOTES- I
1) Wind: ASCE 7-10; Vult=165mph (3-second gust) Vasd=128mph; TCDL=4.2psf; BCDL=3.opsf; h=14ft; B=52ft; L=34ft; eave=6ft; Cat.
11; Exp C; Encl., GCpi=0.18; MWFRS (directional) and C-C Exterjor(2� zone;C-C for members and forces & MWFRS for reactions
shown; Lumber DOL=1.60 plate grip DOL=1.60 1
2) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
3) * This truss has been designed for a live load of 20.Opsf on the bojtto�n chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide
will fit between the bottom chord and any other members.
4) Refer to girder(s) for truss to truss connections. 1
5) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 80 lb uplift at joint 3, 161 lb uplift at joint
2 and 7 lb uplift at joint 4.
Thomas A. Albani PE No.39380
MiTak USA, Inc. FL Cert 6634
G904 Parke East Blvd. Tampa FL 33610
Date:
February 21,2018
WARNING - Verily desIgn parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERANCE PAGE M117473 rev. 10/03)2015 BEFORE USE
Design valid for use only with MITek9 connectors. This design is based only upon parameters shown, and Is for an Indiddual building component. not
a truss system. Before use, the building designer must verify the appll�abgily of design parameters and properly Incorporate Mrs design Into the overall
bullcringdesign. Bracing Indicated Is to prevent buckling ofindividudl truss web and/or chord members only. Additional temporary and permanent bracing
MiTek'
Is always required for stability and to prevent collapse with possible personal Injury and property damage. For general guidance regarding the
fabrication, storage, delivery, erection and bracing of trusses and truss systems� seeANSI/TPI I Quality Criteria, DSB-89 and BCSI Building Component
6904 Parke East Blvd.
Safety Information available from Truss Plate InsIllute, 218 N. LeeStreet. Suite 312, Alexandria. VA 22,M4.
Tampa, FL 33610
Job
Truss
Truss Type
9ty
Ply
rand Carlton III with porch
T13302400
M 11323
J6
MONO TRUSS
8
1
�62'G
J � Reference (optional)
L,narrlDel"S iruss, mc., r-011 M8[Ce, I-L
-1-0-0
2
3x4 =
4.00Fi —2
L�_j7xS)(_p_fXi4uzgyuFU;-QDT4gX�'kl'O'?u[3�E'M'ISB���PUDtd4uE9zqajZOMziuKA
I
6-0-0
Cl
4
Scale = 1:14.6
i 1 6-0-0
LOADING (psf)
SPACING- 2-0-0
CSI-
DEFL. In (loc) I/defl Ud
PLATES GRIP
TCLL 20.0
Plate Grip DOL 1.25
TC q�36
Vert(LL) 0.11 4-7 >629 360
MT20 244/190
TCDL 7.0
Lumber DOL 1.25
BC 0.83
Verl(CT) -0.12 4-7 '>617 240
BCLL 0.0
Rep Stress Incr YES
WB 6.00
Horz(CT) -0.00 3 n/a n/a
BCDL 10.0
Code FBC2017ITP12014
MatrIx-VP
Weight: 20 lb FT=O%
LUMBER- BRACING -
TOP CHORD 2x4 SP M 30 TOPCHORD Structural wood sheathing directly applied or 6-0-0 oc puffins.
BOTCHORD 2x4 SP No.3 BOTCHORD Rigid ceiling directly applied or 10-0-0 oc bracing.
REACTIONS. (lb/size) 3=145/Mechanical, 2=279/0-8-0, 4=71/Mechanical
Max Horz 2=1 42(LC 10)
Max Uplift 3=-1 31 (LC 10), 2=-1 94(LC 10), 4=-8(LC 10)
Max Grav 3=145(LC 1), 2=279(LC 1), 4=102(LC 3)
FORCES. (lb) - Max. Comp./Max, Ten. - All forces 250 (lb) or less excep when shown.
NOTES-
1) Wind: ASCE 7-10; Vult=165mph (3-second gust) Vasd=128mph; TCDI =4.2psf; BCDL=3.Opsf; h=14ft; B=52ft; L=34ft; eave=6ft; Cat.
11; Exp C; Encl., GCpi=O.l 8; MWFRS (directional) and C-C Exterior(2) 11zone;C-C for members and forces & MWFRS for reactions
shown; Lumber DOL=1.60 plate grip DOL=1 �60 1
2) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
3) * This truss has been designed for a live load of 20.Opsf on the bottor� chord in an areas where a rectangle 3-6-0 tall by 2-0-0 wide
will fit between the bottom chord and any other members.
4) Refer to girder(s) for truss to truss connections.
5) Provide mechanical connection (by others) of truss to bearing plate c,apiable of withstanding 131 lb uplift at joint 3, 194 lb uplift at
joint 2 and 8 lb uplift at joint 4:
Thomas A. Albani PE No.39380
MiTek USA, Inc. FIL Cort 6634
6904 Parke East Blvd. Tampa FIL 33610
Date:
February 21,2018
WARNING- Vfify design Paraineten and READ NOTES ON THIS AND INCLUDED MITEK REFERANCE PAGE Mll-7473 rcv. 1010312015 BEFORE USE
Design valid for use only with MlTek6 connectors. This design is based only upon parameters shown, and Is for an Individual building component not
a truss system. Before use, the building designer must verify the applicability of design parameters and property Incorporate this design Into the overall
Bracing Indicated Is to buckling Individual 1�uss web and/or chord members only. Additional temporary and permanent bracing
MiTek'
building design. prevent of
Is always required for stability and to prevent collapse Win possible personal Injury and property damage. For general guidance regarding the
fabrIcallom storage, delivery. erection and bracing of trusses and truss ystem&, seeANSI/TPI I Quality Crilerlo, DSB-89 and BCS1 Building Component
6904 Parke East Blvd.
Safety Information avallable from Truss Plate Institute. 218 N. Lee StreetI.Sulte 312, Mexandilo, VA 22314.
Taff9a, FL 33610
Job
Truss
Truss Type
9ty
Ply
62' Grand Carlton I I I with porch
T13302401
M11323
J8
MONO TRUSS
20
1
Job Reference (optional)
unambers I russ, Inc., I-ort vierce, t-L
9
2
A I
3x4 ��
8
LOADING (pst)
S ACING-
2-0-0
CS1.
TCLL
20.0
Plete Grip DOL
1.25
TC
TCDL
7.0
Lumber DOL
1.25
BC
BCLL
0.0
Rep Stress Incr
YES
WB
BCDL
10.0
Code FBC2017fTP12014
Matr
4.00 F1 _2
. C5.1'Ju soup I oeu I I Ivil I �& I I luu.11M., I . I— — .. —9. ,
ID:tP6jtz-j7xS)Lc-fXi4uzgyuFUG-uPiSutPMWJOCp-pyPZinWXybuH5UdhP73ES7woziuKg
8-0-0 1
3
4
DEFL.
in
(loc)
Well
Ud
PLATES GRIP
Vert(LL)
0.26
4-7
>367
360
MT20 244/190
Vert(CT)
-0.30
4-7
>319
240
Horz(CT)
-0.00
3
n1a
n/a
LUMBER- BRACING-
TOPCHORD 2X4 SP M 30 TOPCHORD
BOTCHORD 2X4 SP M 31 BOTCHORD
REACTIONS. (lb/size) 3=188/Mechanical, 2=352/0-8-0, 4=103/Mechanical
Max Horz 2=1 80(LC 10)
Max Uplift 3=-175(LC 10), 2=-228(LC 10), 4=-1 5(LC 10)
Max Grav 3=188(LC 1), 2=352(LC 1), 4=145(LC 3)
FORCES. (lb) -Max. Comp./Max. Ten. -All forces 250 (lb) or less excepj when shown.
Srale = 1:17.4
Weight: 26 lb FT=O%
Structural wood sheathing directly applied or 6-0-0 oc puffins.
Rigid ceiling directly applied or 10-0-0 oc bracing.
NOTES -
I Wind: ASCE 7-10; Vult=1 65mph (3-second gust) Vasd=1 28mph; TCDI=4.2psf; BCDL=3.opsf; h=1 41t; 8=52ft; L=34ft; eave=6ft; Cat.
11; Exp C; Encl., GCpi=0.18; MWFRS (directional) and C-C Exterior(2)1 1-0-0 to 2-4-13, Interior(l) 2-4-13 to 3-1-13, Exterior(2) 3-1-13
to 7-11-8 zone;C-C for members and forces & MWFRS for reactions s�own; Lumber DOL=1.60 plate grip DOL=1.60
2) This truss has been designed for a 10.0 psf bottom chord live load no n1concurrent with any other live loads.
3) * This truss has been designed for a live load of 20.0psf on the bottom' chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide
will fit between the bottom chord and any other members.
4) Refer to girder(s) for truss to truss connections.
5) Provide mechanical connection (by others) of truss; to bearing plate capable of withstanding 175 lb uplift at joint 3, 228 lb uplift at
joint 2 and 15 lb uplift at joint 4. 1
Thomas A. Albani PE No.35380
MiTak USA, Inc. FL Cert 6634
6904 Parke East Blvd. Tampa Fl. 33610
Date:
February 21,2018
,& WARNING - Verify design parameters and READ NOTES ON THIS AND iNcl LuDEo mrrEKREFERANCE PAGEMII-7473 rev. 10AW016 BEFORE USE
Design valid for use only with MITek8 connectors. This design Is based ohy upon parameters shown. and Is for an Individual building component not
a truss system. Before use, lhe building designer must vedfy the applicability of design parameters and properly Incorporate this design Into the overall
building design. Bracing Indicated Is to prevent buckling of Individual tiuss web and/or chord members only. Additional temporary and permanent bracing
MiTek'
Is always required for stability and to prevent collapse wIth possible personal Injury and property damage. For general guidance regarding the
fabricallon, storage. dellvery� erection and bracing of trusses and truss �ystems. seeANSI/TPI I Quality Criteria, DSB-89 and SCSI Building Component
6904 Parke East Blvd.
Safety information available from Truss Plate Institute. 218 N. Lee Street,f Suite 312, Alexandria, VA 22314.
Tampa, FL 33610
Job
Truss
Truss Type
Qty
Ply
62'Grand Carlt n III with porch
T13302402
M11323
KJ8
MONO TRUSS
4
1
Job Reference (optional)
unamDers I russ, I nc., t-on: vierce, t-L ts.].Ju 5,3ep 10 ev I I Iva I UK lnuubules' 111u. vveu rvu e i i�;eu�uu �v i a rdy� i
I ID:Lcg54J?LuEancmZr4Qb7WMyuFUF-Mcbr5CQ—Hd83Q80gzHD02kUrohRsMlVGHuCgSEziuKs
5 0 7-3-4 11-3-0
1--5--0 7-3-4 3-11-12
Scale = 1:20.3
7-3-4
1
3-11-12
LOADING (pst)
SPACING-
2-0-0
CS1. I
DEFL.
in
(loc)
I/defl
. Ud
PLATES GRIP
TCLL 20.0
Plate Grip DOL
1.25
TC 0.29
Vert(LL)
0.07
7-10
>999
360
MT20 244/190
TCDL 7.0
Lumber DOL
1.25
BC 0.30
Vert(CT)
-0.12
7-10
>999
240
BCLL 0.0
Rep Stress Incr
NO
WB 1 0 ' 46
Horz(CT)
0.02
6
Wa
n/a
BCDL 10.0
Code FBC2017fTPI2014
Matti rMS
Weight: 44 lb FT = 0%
LUMBER -
TOP CHORD 2X4 SP M 30
BOT CHORD 2X4 SP M 30
WEBS 20 SP No.3
REACTIONS. (lb/size) 4=201 /Mechanical, 2=466/0-11-5, 6=576/fv
Max Harz 2=244(LC 8)
Max Uplift 4=-205(LC 8), 2=-305(LC 8), 6=-286(LC 8)
Max Grav 4=245(LC 13), 2=466(LC 1), 6=590(LC 13)
FORCES. (lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less
TOPCHORD 2-3=-1 151/523
BOTCHORD 2-7=-687/1126, 6-7=-687/1126
WEBS 3-7=0/330, 3-6=-1 236[755
NOTES-
1) Wind: ASCE 7-10; Vult=165mph (3-second gust) Vasd=128mph;
11; Exp C; Encl., GCpl=0.18; MWFRS (directional); Lumber DOL=1
2) This truss has been designed for a 10.0 psf bottom chord live load
3) * This truss has been designed for a live load of 20.Opsf on the bol
will fit between the bottom chord and any other members.
4) Refer to girder(s) for truss to truss connections.
5) Provide mechanical connection (by others) of truss to bearing plat(
joint 2 and 286 lb uplift at joint 6.
6) In the LOAD CASE(S) section, loads applied to the face of the truE
BRACING-
TOPCHORD Structural wood sheathing directly applied or 6-0-0 oc pudins.
BOTCHORD Rigid ceiling directly applied or B-9-6 oc bracing.
whenshown.
'L=4.2psf; BCDL=3.Opsf; h=14ft; B=52ft; L=34ft; eave=6ft; Cat.
plate grip DOL=1.60
iconcurrent with any other live loads.
chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide
capable of withstanding 205 lb uplift at joint 4, 305 lb uplift at
are noted as front (F) or back (B).
LOAD CASE(S) Standard I
1) Dead + Roof Live (balanced): Lumber Increase=1.25, Plate Increase=1.25
Uniform Loads (plf)
Vert: 1-2=-54
Trapezoidal Loads (pit)
Vert: 2=0(F=27, B=27)-to-4=-1 52(Fm-49, B=-49), 8=0(F--11 0, B=1 0)-to-5=-56(F=-1 8, B=-1 8)
Thomas A. Albani PE No.39*
MiTak USA, Inc. FL Cart 6634
6904 Parke East Blvd. Tampa FL 33610
Date:
February 21,2018
A WARNING- Verify design parameters and REW NOTES ON THIS AND iNGLUDED MITEKREFERANCE PAGE Mll-7473 rev. 10)V=015 BEFORE USE.
Design valid for use only with MITekG connectors. This design is base� oNy upon parameters shown, and Is for an Individual building component not
a IFLISS SWCM. Before use, the building designer must verify the applicability of design parameters and property Incorporate this design Into the overall
bullcling design. Bracing Indicated Is to prevent buckling of Individual Iniss web and/or chord members only. Additional temporary and permanent bracing
MiTek*
Is always required for stability and to prevent collapse with possible personal Injury and property damage. For general guidance regardling the '
fabrication. storage, delivery, erection and bracing of trusses and truss systems. seeANSI/TPI I Quality Criteria, DSB-89 and BCSI Building Component
6904 Parke East Blvd.
Safety Information available from Truss Plate Institute. 218 N. Lee Street, Suite 312, Alexandria VA 22314.
Tampa, FL 33610
Symbols
PLATE LOCATION AND ORIENTATION
3/�' Center plate on joint unless x, y
offsets are indicated.
Dimensions are in ft-in-sixteenths.
Apply plates to both sides of truss
and fully embed teeth.
0-719,
go -
For 4 x 2 orientation, locate
plates 0-1/id' from outside
edge of truss.
This symbol indicates the
required direction of slots in
connector plates.
Plate location details available in MiTek 20/20
software or upon request
PLATE SIZE.
The first dimension is the plate
width measured perpendicular
--to-slots�Seconcl-climenslonjs
the length parallel to slots.
LATERAL BRACING LOCATION
MIN
Indicated by symbol shown and/or
by text in the bracing section of the
output, Use T or I bracing
if indicated.
Indicates location where bearings
(supports) occur. Icons vary but
reaction section indicates joint
number where bearings occur.
Min size shown is for crushing only.
Industry Standards:
ANSI/TPI1: National Design Specification for Metal
Plate Connected Wood Truss Construction.
DSB-89: Design Standard for Bracing.
BCSI: Building Component Safety Information,
Guide to Good Practice for Handling,
Installing & Bracing of Metal Plate
Connected Wood Trusses.
Numbering System
6-4-8 1 dimensions shown in ft-in-sixteenths
I(Drawings not to scale)
2
TOP CHORDS
0
a-
0
5
JOINTS ARE GENERALLY NUMBEREDAETTERED CLOCKWISE
AROUND THE TRUSS STARTING AT THE JOINT FARTHEST TO
THE LEFT.
CHORDS AND WEBS ARE IDENTIFIED BY END JOINT
NUMBERSAETTERS.
PRODUCT CODE APPROVALS
ICC-ES Reports:
ESR-1 311, ESR-1 352, ESR1 988
ER-3907, ESR-2362, ESR-1397, ESR-3282
0
01
0
a-
0
Trusses are designed for wind loads in the plane of the
truss unless otherwise shown.
Lumber design values are in accordance with ANSI/TP1 1
section 6.3 These truss designs rely on lumber values
established by others.
@ 2012 MITek@ All Rights Reserved
MiTek Engineering Reference Sheet: Mll-7473 rev. 10/03/2015
A General Safety Notes
Failure to Follow Could Cause Property
Damage or Personal Injury
I , Additional stability bracing for truss system, e.g.
diagonal or X-bracing, is always required. See BCSL
2. Truss bracing must be designed by an engineer. For
wide truss spacing, individual lateral braces themselves
rnoy require bracing, or alternative Tor I
bracing should be considered.
3. Never exceed the design loading shown and never
stock materials on inadequately braced trusses.
4. Provide copies of this truss design to the building
designer, erection supervisor. property owner and
all other interested parties.
5. Cut members to bear tightly against each other.
6. Place plates on each face of truss at each
joint and embed fully. Knots and wane atjoint
locations are regulated by ANSI/TPI 1.
7. Design assumes trusses will be suitably protected from
the environment in accord with ANSI/TPI 1.
8. Unless otherwise noted, moisture content of lumber
shall not exceed 19% at time of fabrication.
9. Unless expressly noted, this design Is not applicable for
use with fire retardant preservative treated, or green lumber.
10. Comber is a non-structural consideration and is the
responsibility of truss fabricator. General practice Is to
comber for dead load deflection.
are minimum plating requirements.
12. Lumber used shall be of the species and size, and
in all respects, equal to or better than that
specified.
13. Top chords must be sheathed or purlins provided at
spacing indicated on design.
14. Bottom chords require lateral bracing at 1 Oft. spacing,
or less, if no ceiling is installed, unless otherwise noted.
15. Connections not shown are the responsibility of others.
16. Do not cut or alter truss member or plate without prior
approval of an engineer.
17. Install and load vertically unless Indicated otherwise,
18. Use of green or treated lumber may pose unacceptable
environmental, health or performance risks. Consult with
project engineer before use.
19. Review all portions of this design (front back, words
and pictures) before use. Reviewing pictures alone
is not sufficient.
20. Design assumes manufacture in accordance with
ANSI/TPI 1 Quality Criteria.