Loading...
HomeMy WebLinkAboutDRAWING GENERATOR"pu, ST LUCIE COUNW PLAN REVIEW o ELE co (Y)(' . v bxtell:�- PLLNB:— C c- fs Trk DATE�' MECH'— DAM—� RtCEI\1�15--- APR 2 5 2018 ST. Lucie County, Permitting r L(L-, C' I MO Cern orv,1-6 r a0A kj ted I COMFORT CONTROL SERVICES PHONE: 772-785-7075 FAX: 772-785-9144 PROJECT: DAVID NAUGLE . LOCATION: 15367 SKYLINE DRIVE EXISTING FEEDER SIZE: 4/0 AU EXISTING PANEL SIZE: 200 MAIN BREAKER SIZE: 200 NIJMRFR nF RRFAKFRS: 30 k�bEIVF-b APR 2 5 2018 ST. Lucie County, Per mitOno EXISTING LOADS WATTS 2,768 SQ FEET X 3 WATTS PER SQ FT 8,304 2 APPLIANCE CIR @ 1500 WATTS EACH 3,000 1 LAUNDRY CIR @ 1500 WATTS EACH 1,500 1 RANGE @ 8 KW 8000 1 DISHWASHER AND DISPOSAL @ 1500 WATTS EACH 3,000 1 MICROWAVE @ 200 WATTS)' 2,000 1 WATER HEATER @ 4.5 KW 4500 TANKLESS WATER HEATER 1 DRYER @ 5 KW 5,000 1 REFRIGERATOR @1500 WATTS EACH 1,500 2 BATHROOM 1 @ 1500 WATTS 3,000 SPRINKLER PUMP POOL PUMP POOL LIGHT HEAT PUMP CHLORINE GENERATOR AIR BLOWER BOATLIFT OTHER OTHER OTHER TOTAL: 39,804 FIRST 10 KW @ 100% 10,000 29,804 REMAINDER @ 40% 11,921 2 TOTAL WATTS: 21,921 21,921 DIVIDED BY 240 VOLTS 91.3 IPREPAIRED BY: WAYNE ZIMIVIERM�N DATE: 4/25/18