EVALUATION REPORT
APR 2 5 20418
nty, Permittiog
EXTERIOR RESEARCH & DESIGN, LLC.
Certificate ofAuthorization #9503
353 CHRISTIAN STREET, UNIT#13
OXFORD, CT 06478
PHONE: (203) 262-9245
FAX: (203) 262-9243
Interwrap, Inc.
32923 Mission Way THESE PLANS AND ALL PROPOSED WORK Evaluation Report 111980-11.08-113
ARE SUBJECT TO ANY CORRECTIONS FI-11602-113
Mission, BC V2V-6E4 REQUIRED BY FIELD INSPECTORS THAT Date of Issuance: 11/03/2008
Canada MAY BE ' WY IN ORDER TO Revision 3:05/01/2015
COMEN,EREASALL APPLICABLE CODES.
SCOPE:
This Evaluation Report is issued under ule 61G20-3 and the applicable rules and regulations governing the use of
construction materials in the State of Flor �, -1
-M. The documentation submitted has been reviewed by Robert Nieminen, P.E. for
use of the product under the Florida Bui�cling Code and Florida Building Code, Residential Volume. The products described
herein have been evaluated for complian, ce with the 5 th Edition (2014) Florida Building Code sections noted herein.
DESCRIPTION: Titanium' Roof Underlaviments
LABELING: Labeling shall be in accorclad, ce with the requirements the Accredited Quality Assurance Agency noted herein.
CONTINUED COMPLIANCE: This Evaluat�Zn Report is valid until such time as the named product(s) changes, the referenced
Quality Assurance documentation cp anges, or provisions of the Code that relate to the product change. Acceptance of this
Evaluation Report by the named client constitutes agreement to notify Robert Nieminen, P.E. if the product changes or the
referenced Quality Assurance doc /,mentation changes. Trinity I ERD requires a complete review of this Evaluation Report
relative to updated Code require ents with each Code Cycle.
ADVERTISEMENT: The Evaluation�le p ort number preceded by the words "TrinitylERD Evaluated" may be displayed in
30 1
ic
advertising literature. If any 1 0 n of the Evaluation Report is displayed, then it shall be done in its entirety.
INSPECTION: Upon request, a copy of this entire Evaluation Report shall be provided to the user by the manufacturer or its
distributors and shall be availa& for inspection at the job site at the request of the Building Official.
I
This Evaluation Report
Prepared by:
of pages I through 6.
Robert J.M. Nieminen' P E'
Florida Registration No. 5916�)Florido DCA ANE1983
CERTIFICATION OF INDEPEN
1. TrinityJERD does
distributing produ
2. Trinity I ERD is not
3. Robert Nieminen,
which the evaluat
4. Robert Nieminen/
product. 7
CONCEALED FASTENERS OR ATTACHMENTS
ARE THE RMPON131BILITY OF THE
13 "-N-,'Viw0R 02 Fr40,90
FILE COPY - -
The faainnfle seal appearing was authorized by Robert Nieminen,
p * E. on 0510112015. This does not serve as an electronically signed
document. Signed, sealed handcapies have been transmitted to the
Product Approval Administrator and to the named client
no / It have, nor does it intend to acquire or will it acquire, a financial interest in any company manufacturing or
:ts it evaluates.
o�necl, operated or controlled by any company manufacturing or distributing products it evaluates.
P.E. does not have nor will acquire, a financial interest in any company manufacturing or distributing products for
on reports are being issued.
P E does not have, nor will acquire, a financial interest in any other entity involved in the approval process of the
5. This is a buildin c d evaluation. Neither Trinityl ERD nor Robert Nieminen, P.E. are, in any way, the Designer of Record for any
project on whicl� this Evaluation Report, or previous versions thereof, is/was used for permitting or design guidance unless retained
specifically for that purpose.
ST. LUCIE COUNTY BUILDING DIVISION
REVIEWED FOR COMPLIANCJ��
REVIE� -D
DATE
P S
LANS AND PERMIT LIST BE K PT ON JOB
SITE OR No INSPECTION(S) WILL BE MADE
Q0TPt1N1TYJERD
ROOFING COMPONENT EVALUATION:
1. SCOPE:
Product Category: Roofing
Sub -Category: Underlamen'
Compliance Statement: TitaniUMTm Roof U nderlaiments, as produced by Interwrap, Inc., have demonstrated compliance with
the intent of the following sections of the Florid I Building Code through testing in accordance with applicable sections the
following Standards. Compliance is subject to the I stallation Requirements and Limitations / Conditions of Use set forth herein.
2. STANDARDS:
Section Pro ert Standard Year
15 07.2.3, 1507.3.3, 1507.5.3, 1507.7.3, Unrolling, Bre?king Strength, Pliability, ASTM D226 2006
T1507.8, 1507.8.3, 1507.9.3 Loss on Heati g
1507.2.4, 1507.2.8, 1507.2.9.2, Thickness, Lo d-Strain, Adhesion, Thermal ASTM D1970 2009
1507.4.5.1, 1507.4.5.2, 1507.5.3, Stability, Flexi ility, Tear, Permeance
1507.5.3.2, 1507.7.3, 1507.7.3.2
1507.3.3 Installation PLtice FRSA/TR1 April 2012 (04-12) 2012
1523.6.S.2.1 Physical Prop rties (2-ply system) TAS103 1995
TAS110 Accelerated eathering TAS110 2000
3. REFERENCES:
Kaml Examination Reference Date
ERD (TST6049) Physic@ Pro�erties 115010.04.09 04/29/2009
ERD (TST6049) Physica Properties 115010.05.10 05/14/2010
ERD (TST6049) Physical Properties 135520.06.11 06/15/2011
ERD (TST6049) Wind Upliftl 135520.08.11-1 08/12/2011
ITS(TST1509) Phys:ical P rt' s 3146738COQ-003A 03/28/2008
Phys c. p:lt::, 3146738COQ-003B 03/28/2008
ITS (TST1509) I Pr�p
ITS(TST1509) Physical Pr perties 3126617COQ-005 10/31/2007
ITS (QUA1673) Quality Co trol ITS Listings Current
ITS (QUA1673) Qual:ty Co trol Inspection Report 11/19/2014
4. PRODUCT DESCRIPTION:
4.1 Self -Adhering Underlayments:
4.1.1 Titanium" PSU-30 is an unreinforced I polymer modified bitumen material adhered to the underside of a polymer -
coated, synthetic woven sheet. The underside is backed with a release film. Unit weight 24 lbs/square.
4.2 Mechanically Fastened UnderianimentL
4.2.1 Titanium— UDL-25 is a synthetic she I let -type underlayment comprised of a woven core coated on one side with a
polymer coating. Unit weight 2.5 lbs/square.
4.2.2 TitaniUMTM UDL-25 PLUS is a synthetij sheet -type underlayment comprised of a woven core coated on one side with a
polymer coating. Unit weight 2.9 lbs/ quare.
4.2.3 Titanium— UDL-30 is a synthetic sh 2ict-type underlayment comprised of a woven core coated on both sides with a
polymer coating. Unit weight 4.0 lbs/square.
4.2.4 Titanium— UDL-50 is a synthetic sh I coated on both sides with a
,jet -type underlayment comprised of a woven core
polymer coating. Unit weight 4.7 lbs/ quare.
4.2.5 Titanium— UDL-TT is a synthetic shelet-type underlayment comprised of a woven core coated on one side with a
polymer coating. Unit weight 2.9 lbs I quare
4.2.6 Titanium" UIDL-TF is a synthetic sheet- pe underlayment comprised of a woven core coated on both sides with a
polymer coating. Unit weight 2.9 lbs square.
4.2.7 UDL-TrMC300 is a synthetic sheet -type underlayment comprised of a woven core coated on both sides with a polymer
coating. Unit weight 3.2 lbs/square.
Exterior Research and Design, LLC. Evaluation Report 111980.11.08-113
Certificate afAutharizotion #9503 FL11602-R3
Revision 3: 05/01/2015
Page 2 of 6
S. LiMITATIONS:
5.1
5.2
5.3
5.4
5.5
This is a building code evaluation. Neithe
Record for any project on which this Evalt
design guidance unless retained specifically
This Evaluation Report is not for use in the F
Fire Classification is not part of this report;
product.
Titanium" Roof Underlayments may be US
within FBC approval documents. If not li't�
combined with supporting data for the pre
All —A —WO Pnnf rnwarv., 11
TrinityJERD nor Robert Nieminen, P.E. are, in any way, the Designer of
ition Report, or previous versions thereof, is/was used for permitting or
)r that purpose.
to current Approved Roofing Materials Directory for fire ratings of this
d with any prepared roof cover where the product is specifically referenced
d, a request may be made to the AHJ for approval based on this evaluation
ared roof covering.
Table I- Roof Cover Options
Underlayment
Asphalt
Nail -On Tile
Foam -On Tile
Metal
Wood Shakes &
Shingles
Slate
Shingles
PSU-30
Yes
Yes
Yes
Yes
Yes
Yes
(See 5.5.1)
UDL-25
Yes
No
No
Yes
Yes
Yes
Yes
Yes
UDL-25 PLUS
Yes
base layer in 2-
(base layer in 2-
Yes
Yes
Yes
ply system)
ply system)
Yes
Yes
UDL-30
Yes
(base layer in 2-
(base layer in 2-
Yes
Yes
Yes
ply system)
ply system)
UDL-50
Yes
No
No
Yes
Yes
Yes
UDL-TT
Yes
No
No
Yes
Yes
Yes
UDL-TF
Yes
No
No
Yes
Yes
Yes
t UDL-T-rMC300
Yes
No
Yes
Yes
Yes
'Private Labeled
5.5.1
"Foam -On Tile" is limited to use of 3M'":
Adhesive (FL717) applications unless tensil
provided.
5.6
Allowable Substrates; Titanium PSU-30:
5.6.1
DireCt-Bond t9 Deck:
> New untreated plywood;
> Existing untreated plywood, primed as
5.6.2
Bond to Mechanically Attached Base She
> ASTM D226, Type I or 11 felt.
> Titanium UDL-25 PLUS, UDL-30 (prime
5.6.3
NA/ind Resistance for Underlayment Syste
wind uplift resistance of all underlaymei
of the load -path. The following wind
FRSA/TRI April 2012 (04-12) and are use(
for wind load resistance based on allowa
1 margin of safety per FBC 1504.9 has all
or FBC 1609 for determination of design
5.6.3.1 Maximum Design Pressure = -45 ps -
Deck: Min. 15/32-inch plyi
Primer: (Optional) ASTM D4
Underlayment: Titanium PSU-30, se
:omponent Foam Roof Tile Adhesive AH-160 (FL6332) or Dow TILE BOND'" Roof Tile
adhesion / long term aging data from an accredited testing laboratory is
needed with D41 primer to achieve bond.
I with D41 primer) or UDL-30 (inverted).
is in Foam -On Tile Applications: FRSA/TRI April 2012 (04-12) does not address
systems beneath foam -on tile systems, where the underlayment forms part
plift limitations apply to underlayment systems that are not addressed in
in foam -on tile applications. Maximum Design Pressure is the result of testing
le wind loads, and reflects the ultimate passing pressure divided by 2 (the 2 to
ady been applied). Refer to FRSA/TRI April 2012 (04-12), Appendix A, Table 1A
iind loads.
to meet project requirements to satisfaction of AHJ.
hered
Exterior Research and Design, LLC. Evaluation Report 111980.11.08-113
Certificate ofAuthorization #9503 F1.11602-1113
Revision 3: 05/01/2015
Page 3 of 6
5.6.3.2
TRINITYIERD
Maximum Design Pressure = -30 psf*
Deck: Min. 15/32-iinch pl � wood to meet project requirements to satisfaction of AHJ.
Base Sheet: Titanium UDL_25 P -
a�US or UDL 30 (inverted)
h,
Fasteners: Mechanically atta hed with 12 ga. annular ring shank nails having not less than 20 rings per inch,
heads not less th 1 3/8 inch diameter and length sufficient to penetrate through the thickness of
n 11
S, -inch with min. 32 ga., 1-5/8" diameter tin caps
deck not le s than 3/16
Spacing: 6-inch o.c. at 4-Sh wide side laps and 12-inch o.c. at three (3), equally spaced center rows.
Primer: ASTM D41 prime required at all tin -caps.
Titanium P! self -adhered
Underlayment: I.
5.6.3.3 Maximum Desi
Deck:
Base Sheet:
Fasteners:
Spacing:
Primer;
Underlayment:
5.6.3.4 Maximum Desi
Deck:
Base Sheet:
Fasteners:
Spacing:
Primer:
Underlayment:
5.6.3.5
2ssure = -.iu pbi -. I
Min. 15/32-inch � lywood to meet project requirements to satisfaction of AHJ.
Titanium UDL-30 I (printed side up)
Mechanically a ached with 12 ga. annular ring shank nails having not less than 20 rings per inch,
heads not less t an 3/8 inch diameter and length sufficient to penetrate through the thickness of
deck not less th n 3/16-inch with min. 32 ga., 1-5/8" diameter tin caps.
G-inch o.c. at 4-'nch wide side laps and 12-inch o.c. at three (3), equally spaced center rows.
ASTM D41 prim I r required over printed side of UDL-30.
Titanium PSU 3P, self -adhered
2ssure = -4:��
r
5T
Min. 15/32. nl plywood to meet project requirements to satisfaction of AHJ.
TitaniumUDL 5 PLUS orUDL-30 (inverted)
Mechanica ' -Ittached with 12 ga. annular ring shank nails having not less than 20 rings per inch,
heads not les than 3/8 inch diameter and length sufficient to penetrate through the thickness of
deck not less han 3/16-inch with min. 32 ga., 1-5/8" diameter tin caps
6-incho.c.at -inch wide side laps and 8-inch o.c. at three (3), equally spaced center rows.
ASTMD41pri er required at all tin -caps.
Titanium PSU130, self -adhered
maximum uesign F'ressure = -4z
Deck: Min. 15/32
Base Sheet: Titanium U
Fasteners: Mechanica
heads not
deck not IE
Spacing: 6-inch o.c.
Primer: ASTM D41
Underlayment: Titanium P
5.6.3.6 For mechanically attached bas,
meet or exceed the Zone I de
Table 1A or FBC 1609. Zones 2
resist the elevated pressure (
Assemblies marked with an asi
enhancements
5.7 Exposure Limitations: I
Titanium UDL-25, UDL-25 PLUS
Titanium PSLI-30 shall not be I I ic
UDL-TTMC300 not be left expp
Exterior Research and Design, U-C.
Certificate ofAuthorization #9503
I
-inch plywood to meet project requirements to satisfaction of AHJ.
) 30 (printed side up)
ly�attached with 12 ga. annular ring shank nails having not less than 20 rings per inch,
dss than 3/8 inch diameter and length sufficient to penetrate through the thickness of
than 3/16-inch with min. 32 ga., 1-5/8" diameter tin caps.
it 4-inch wide side laps and 8-inch o.c. at three (3), equally spaced center rows.
primer required over printed side of UDL-30.
I U 30, self -adhered
sheet in a 2-ply system, the maximum design pressure for the selected assembly shall
;Ign pressure determined in accordance with FRSA/TRI April 2012 (04-12), Appendix A,
and 3 shall employ an attachment density designed by a qualified design professional to
riteria. Commonly used methods are RAS 117, FM LPDS 1-29 and ANSI/SPRI WD1.
�risk* carry the limitations set forth in Section 2.2.1.5.1(a) of FM LPDS 1-29 for Zone 2/3
UDL-30, UDL-50, UDL-TT or UDL-TF shall not be left exposed for longer than 30-days.
t exposed for longer than 90-days.
ed for longer than 180-days.
Evaluation Report 111980.11.08-113
FL11602-R3
Revision 3: 05/01/2015
Page 4 of 6
6. INs-rALLATION:
6.1
6.2
Titanium Roof Underlayments shall be installed in accordance with Interwrap published installation requirements
subject to the Limitations set forth in Sec ion 5 herein and the specifics noted below.
Re -fasten any loose decking panels, and check for protruding nail heads. Sweep the substrate thoroughly to remove
any dust and debris prior to application, ;, nd prime the substrate (if applicable).
6.3 Tita niurn— U DL-Z5, U LX-25 P LUb. U UL-J , U u L-bu, u u L- I I , u uL� i r d FJU I rF 1Vd LC Ld UCIC. I U 1 1 — � —
6.3.1 Install in compliance with manufacturer's published installation instructions and the requirements for ASTM D226, Type
I and 11 underlayments in FBC Sections 15 1 07 for the type of prepared roof covering to be installed.
6.3.2 Fasteners: I
Mechanical attachment of Titanium U L-25, UDL-25 PLUS and UDL-30 is limited to ring shank roofing nails with
minimum 1-inch diameter plastic caps.
Mechanical attachment of UDL-50, UDL-TT, UDL-TF and (Private Labeled) UDL-TTMC300 is limited to ring shank roofing
nails with minimum 3/8-inch diameter heads; ring shank roofing nails with minimum 1-inch diameter plastic caps;
screws and plates; or plastic cap staples.
6.3.3 Slopes of 4:12 or greater:
End (vertical) laps shall be minimum 6-in ches and side (horizontal) laps shall be minimum 4-inches.
Minimum attachment shall be 12-inche P o.c. vertically and 24-inches o.c. horizontally in accordance with the surface
markings on the exposed face of the underlayment. When batten systems are to be installed atop the underlayment,
the underlayment need only be preliminbrily attached pending attachment of the battens.
6.3.4 Slopes of 2:12 to less than 4:12:
Double layer application; begin by fast I Ling a 25-inch wide strip along the eaves. Place a full -width sheet over the
starter, completely overlapping the sta Iter course. Continue as noted in 6.3.3, but maintaining minimum 25-inch side
(horizontal) laps, resulting in a clouble-11yer application.
6.4 Titanium— PSU-30:
6.4.1 Install in compliance with manufactur�r's published installation instructions and the requirements for ASTM D1970
underlayments in FBC Sections 1507 for I the type of prepared roof covering to be installed.
6.4.2 Direct -to -Deck with Mechanically Fastened Roof Cover:
6.4.3
Cut manageable sections and re -roll v
Membrane Application:
> Peel back release film approximat
side up.
> Apply the balance of the membra
place.
> Apply subsequent courses parallel
> End (vertical) laps shall be minimu
> if the membrane becomes misalig
> Upon completion, inspect the mei
The use of sealant or mastic at tile fa
for approved sealant or mastic types.
Reference is made to FRSA/TRI April :
instructions noted above as a guidelini
Wait a minimum of 24 hours prior to
the roof underlayment.
The use of sealant or mastic at tile fa�
for approved sealant or mastic types.
Exterior Research and Design, LLC.
Certificate ofAuthorization #9503
the release film side out.
1 to 2 feet and align with the lower edge of the roof and set in place, printed
to the substrate by removing the film and firmly pressing the membrane into
the eave in a shingle -type, water -shedding manner.
12-inches and side (horizontal) laps shall be minimum 3-inches.
JI, cut the roll and re -start.
rane and repair any defects or fish -mouths.
!ner penetrations is required for all tile roofing installations. Contact Interwrap
(04-12) Installation Manual and Table 1 and Section 5.6.2 herein, using the
ding roof tiles. Tiles shall be staged so as to avoid slippage and/or damage to
penetrations is required for all tile roofing installations. Contact Interwrap
Evaluation Report 111980.11.08-R3
FL11602-R3
Revision 3: 05/01/2015
Page 5 of 6
I 1 4
7.
B.
9.
6.5 Titanium 2-Ply System:
6.5.1 The Titanium System consists of a bas
mechanically attached to the wood roof c
6.5.2 Non -Tile Applications:
Install Titanium UDL-25 PLUS or UDL-30
6.3.3 followed by Titanium PSU-30 in accc
6.5.3 Tile Applications:
Reference is made to FRSA/TRI April 20J
above as a guideline.
For mechanically fastened tile roofing, r
April 2012 (04-12), Table 1.
For adhesive -set tile roofing, rel
Wait a minimum of 24 hours prior to lo I
the roof underlayment. I
The use of sealant or mastic at tile faste
for approved sealant or mastic types.
BUILDING PERMIT REQUIREMENTS:
As required by the Building Official or Authority Ha,
MANUFAcTURING PLANTS:
Contact the named CIA agency for information on
QUALITY ASSURANCE ENTITY:
Intertek Testing Services NA Inc.-ETL/Warnock
Exterior Research and Design, U.C.
Certificate ofAuthorization #9503
- IF,
layer of Titanium UDL-PLUS or UDL-30 (top -surface primed or inverted)
:k followed by Titanium PSU-30, self -adhered.
(top surface primed or inverted) in accordance with Sections 6.3.1 through
rdance with Section 6.4.
(04-12) Installation Manual and Table I herein, using the instructions noted
!r to Interwrap published installation instructions, but not less than FRSA/TRI
)n 5.6.3 herein.
Ing roof tiles. Tiles shall be staged so as to avoid slippage and/or damage to
!r penetrations is required for all tile roofing installations. Contact Interwrap
Jurisdiction in order to properly evaluate the installation of this product.
uction locations covered by F.A.C. Rule 61G20-3 CIA requirements.
y — QUA1673; (604) 520-3321
OF EVALUATION REPORT -
Evaluation Report 111980.11.08-R3
FL11602-113
Revision 3: 05/01/2015
Page 6 of 6