HomeMy WebLinkAboutPRODUCT EVALUATION REPORTf�E-CEIVED APR 2 6 2`1018 ST. Lucie CountY, PermiffIT19 SCANNED By GULF COAST 26 Ga. SV FL# 11651.13 R8 - OCTOBER 5, 2017 I X� N " 0 0, r *- Gulf CZ�QW SUPPLY & MANUFACTURING Evaluation Report Ly & MANUFACTURING, LLC. Roof Panel over 15132" Piywood a Product Approval #11651.13 R3 Florida Building Code 2017 Per Rule 61 G20-3 Method: 1 -D Category: Roofing Subcategory: Metal Roofing Compliance Method: 61 G20-3.005(l)(d) NON HVHZ Product Manufacturer: Gulf Coast Supply & Manufacturing, LLC. 14429 SW 2nd Place, Suite G30 Newberry, FL 32669 %%% VgF-L S Engineer Evaluator: Dan Kuhn, PE. #75519 Florida Evaluation ANE ID: 10743 Valiclator: Locke Bowden, PE. #49704 9450 Alysbury Place Montgomery, AL 36117 Contents: Evaluation Report Pages 1 - 5 No. 7551 9 STATE OF .'Izz -40RI -"'7" % Thickness: 0.018Y Minimum Width: 24" Coverage Rib Height: 3/a " M I. or Rib #9-1 5x1.5" with sealin� washing in the flat of the panel or approved equal, 1/4" minimum penetrat' on through plywood. Corrosion Resistance: Pe r Florida Building Code 2017, Section 1506.6, 1507.4.4 Minimum 1-9/32" thick ' APA Rated plywood over supports at maximum 24" O.C. Design of plywood and p I lywood supports are outside the scope of this evaluation. Must be designed in accordance w/ Florida Building Code 2017. Table "A" Fastener Pattern 12"-12" 9.5"-2"-9.5" 0 R Design Pressure includes a' Safety Factor 2.0. Z0,r"4..W--X- GuIfU70f SUPPLY & MANUFACTURING TM Compliance Statement: The product as clescr�bed in this report has demonstrated compliance with the Florida Building CM 2017, Sections 1504.3.2. Product Description: 5V Crimp Roof Panel� 26 Ga. Steel, 24" Coverage, through fastened roof panel with fastei�lers in the panel flat over minimum'5/32 "plywood decking. Non Structural application. I Panel Material/Standards: Material: Minimum 26 Ga. Steel, ASTM A792 or ASTM A653 G90 conforming to Florida Building Code �101 7 Section 1507.4.3. Paint Finish Optional Yield Strength: 80.0 k i Corrosion Resistance- Panel Material shall comply with Florida Building Code 2017, Section 1 �,07.4.3. Panel Dimension(s): Panel Fastener: Substrate Description: Design Uplift Pressures: FL# 11651.13 R3 0 OCTOBER 5, 2017 Gulfczw�f SUPPLY & MANUFACTURING TIM Code Compliance: The product described herein has demonstrated compliance with the Evaluation Report Scope: Florida Building Code 20 17, Sections 1504.3.2. The evaluation� is limited to compliance with the structural wind load product requirer - rida Building Code 2017, as relates to Rule 61 G20-3. Performance Standards: The product described herein has demonstrated compliance with: UL 580-06 - Test for Uplift Resistance of Roof Assemblies UL 1897-12 - Uplift Test for Roof Covering Systems. Reference Data: 1 UL 580-94 /1897-98 Uplift Test Force Engineering & Testing, inc. (FBC Organization # TST-5328) Report No. 11 7-0053T-05 & 117-033 1 T-08 2. Certificate of Indepen ence By Dan Kuhn, P.E�. (FL 75519) @ Kuhn Engineering, LLC (FBC Organizatio n, NEID:10743) Test Standard Equivalence: 1 . The UL 580-94 te st standard is equivalent to the UL 580-06 test standard. 1 2. The UL 1897-98 test standard is equivalent to the UL 1897-12 test standard. Quality Assurance Entity: The manufacturer has established compliance of roof panel products in accordance with the Floricl� Building Code and Rule 61 G20-3.005(3) for I manufacturing under a quality assurance program audited by an approved quality assurance entity. Minimum Slope Range: installation: Underlayment: Roof Panel Fire Classification: Shear Diaphragm: FL# 11651.13 R3 0 OCTOBER 5, 2017 HOW14 Minimum Slope shall compl� Section 1507.4.2 and in acco slopes less than 3:12, lap sea install per Manufacturer's rec Shall comply with Florida Buil Fire classification is not part c Shear Diaphragm values are ( with Florida Building Code 2017, including rdance with Manufacturers recommendations. For lant must be used in the panel side laps. mended details. q Code 2017 section 1507.1.1. this acceptance. cle the scope of this report. G61iCaLaozL SUPPLY & MANUFACTURING Design Procedure: For roofs within the pal ameters listed on the load table, fastening pattern must at a minimum meet those listed for the applicable wind zone. For all roofs outside the parameters listed on the load table, design wind loads shall be determined for each project in acco dance with FBC 2017 Section 1609 or ASCE 7-10 using allowable stress d sign. The maximum fastener spacing listed herein shall not be exceeded. This e aluation report is not applicable in High Velocity Hurricane Zone. Refer to urrent NOA or HVHZ evaluation report for use of this product in High Veloc �Curricane Zone. FL# 11651.13 R3 - OCTOBER 5, 2017 ENGINEER LOAD TABLE: 26 Ga. 5VCrimp Roof Panel ov4r 15/32" Plywood VME 'R f722, 1 140 150 160 170 180 ON CENTER ON CENTER ON CENTER ON CENTER ON CENTER ene ra on SPACING SPACIN SPACING SPACING SPACING SPACING SPACING z , ams—* ra VPF' 5* M ZONE 2 #9-15xl.S" Plywood 16" PE 1 16" TYPE I I 16"TYPE1 16"TYPE1 16" TYPE 1 16" TYPE 1 16"TYPE1 'W W 1/5 g� ga poWE24i, t1k, —'77 1.) PANEL DESCRIPTION: 5V CRIMP, MIN. 26 GA., GRADE 80,24"Cl OVERAGE. 2.) PANEL FASTENER: #9-15X1.5" HWH WITH SEALING WASHER 4 MIN. 1/4" PENETRATION. 3.) MAXIMUM ALLOWABLE PANEL UPLIFT PRESSURE: -94.25 PS I �@ 16" O.C. FASTENER SPACING TYPE 1 FASTENER PATTERN, -131.0 PSF @16" O.C. FASTENER SPACING TYPE 2 FASTENER PATTERN BASED ON TAS 125; UL 580/UL 1897 TESTING. CODE 2017. 4.) PLYWOOD DECKING: MIN. 1-1/32" THICK PLYWOOD MUST BE DE� I IGNED IN ACCORDANCE WITH FLORIDA BUILDING 5.) ROOF SLOPE: ON ROOF SLOPES LESS THAN 3:12, LAP SEALANT �UST BE USED IN PANEL SIDE LAPS. 6.) LOAD TABLE BASED ON WIND PRESSURES CALCULATED PER ASCE 7-10 (KD = 0.85) MULTIPLIED BY 0.6 PER FLORIDA BUILDING CODE 2017. //�ONE 2 ZONE 3—,, RIDGE ----------- ZONE 1 N ------------------ Note: Dimensibn (a) is defined as 10% ot the minimum wiciin or iLne uu iluilly ul -4a 40% of the rn�an height of the roof, whichever is smaller, however, (a) cannot be less than either 4% of the minimum width of the building or 3 feet. ZONE 2 GABLE ROOF 11#1 ---------------- i ----- -- �RIDGE -------- L- ----- ---------------------- 4- a _ja ZONE I �ZONE 3 —LAVC FL# 11651.13 R3 * OCTOBER 5, 2017 TYPE I FASTENER PATTERN ) #9-15 x 1-1/2" HWH w/Sealing Washer -1211 f 1211 At Panel Lap TYPE 2 FASTENER PATTERN -(1) 1 #9-15 x 1-1/2" HWH w/Sealing Washer 211 �j- 9.511 ------- f 2111