Loading...
HomeMy WebLinkAboutTRUSSMiTek fi4U0UJdrJ11JJS AS ft- am RE: M1 1412 - CARLTON 290 Lumber design values are in accordance with ANSI/TPI 1 sectiop These truss deligns rely on lumber values established by others. Site Information: Customer Info: Wynne Development Corp Project Lot/Block: Subdivisi Address: unknown City: St Lucie County State: FL Name Address and License # of Structural Ei Name: Address: City: MiTek USA, Inc. 6904 Parke East Blvd. M1 1412 Model: Tampa, FL 33610-4115 of Record, If there is one, for the building. ense #: General Truss Engineering Criteria & Design Load (individual Truss Design Drawings Show Special Loading Conditions): Design Code: FBC2017/TP12014 De ign 11�rogram: MiTek 20/20 8.1 Wind Code: ASCE7-10 Wil d Speed: 165 mph Roof Load: 37.0 psf Fl�or Load: N/A psf This package includes 18 individual, dated Truss Design Drawings and 0 Additional Drawings. With my seal affixed to this sheet, I hereby certify that I am the Truss Design Engineer and this index sheet conforms to 61 G 15-31.003, section 5 of the Florida Board of Professional Engineers Rules. I No. I.Seal# I Truss Name I Date � I No. I Seal# I Truss Name I Date 28 t KJA8 _13/22/18 11 IT136696111A 13/22/18 18 T1 35696 12 IT13569612JAl 13/22/18- 13 1 T1 3569613 1 A2 13/22/18 14 IT13569614IA3 13/22/19 15 1 T1 3569615 1 A4 13/22/18 1 16 1 T1 3569616 1 A5 13/22/18 17 T1 3569617 1. ATA 13/22/18 18 T1 3569618 1 AT6, 3/22/18 19 1 T1 3569619 1 ATC 13/22/18 110 1 T1 35696201 BHA 13/22/18 Ill I T1 35696211 G RA 13/22/18 1 112 IT13569622IJ2 13/22/18 113 IT13569623IJ4 13/22/18 114 IT13569624IJ6 13/22/18 1 115 IT _?5 5 A9p?__[J8 .13/22/18 — J 116 IT135696261JA8 13/22/18 1 39% FILE COFY 117 IT135696271KJ8 13/22/18 1 The truss drawing(s) referenced above have been prepared y M Tek If, R P USA, Inc. under my direct supervision based on the parameters provided by Chambers Truss. E IV Truss Design Engineer's Name: Finn, Walter N o 2�i My license reneWal date for the state of Florida is February 28, 2019. IMPORTANT NOTE: The seal on these truss component designs is a certification 13 % ANTE OF that the engineer named is licensed in the jurisdiction(s) identified and th�t the 0 . - designs comply with ANSI/TPI 1. These designs are based upon param6ters shown (e.g., loads, supports, dimensions, shapes and design codes), wh�ch 10i ;<O. were 4.0 R I VX- N .. ...... C4 given to MiTek. Any project specific information included is for MiTek's customers 0 N A Li�� file reference purpose only, and was not taken into account in the prepar�tion of 111111111,10% these -.designs. MIT& has not independently verified the applicability of t6e, design parameters or the designs for any particular building. Before use, the bul ding designer War P. Firm PE No.22839 - should verify applicability of design parameters and properly incorporate hese designs mrrok USA, Inc. K Con 604 into the overall building design per ANSI/TPI 1, Chapter 2. 6984 Paft East Blvd. Tampa FL33610 Date. March 22,2018 Finn, Walter 1 Of I Job Truss Truss Type Qty Ply CARLTON 299 T1356.9611 M 11412 A SPECIAL 1 Job Reference (optional) L'naMDerS I russ, I ne., r-ori vierce, t-L B-6-0 too! 11 -0 19 5-3 MOO 8-6-0 k4-_0 510-0 5--9-3 — 5XB 4x5 4.00 F1 2 3x6 3 4 24 265 23 2 6 �2 3X6 — 9-10-0 16 15 3x4 5X8 0. 1 JU 5 IVIUI I I 4U I D IVII I UK I I 11.11.1bUlUb, If W. I I IU IVIdl ee VU;V1;0U eU 10 rdye I ID:kFvnsnOwY4l9ZhO-nM3lc6ylJgg-Kxmhf24KxOBwioTmEHbuMgbSnjsl?A78qtMOJzYQn7 I _? 0 8 �%4 36-0-0 q 7-0- 6L8-;5 I _ 7-2-12 1-0-0 x6 = 4x5 6 7 14 4x4 :z 2.00F1_2 5xi 2 MT1 8HS 26 27 8 3x4 9 13 12 7x8 MT18HS = 3x4 Zz Scale = 1:63.0 28 1 Ich 6 4x­10 zz LOADING (psf) SPACING- 2-0-0 CS1. DEFL in (loc) I/detl Ud PLATES GRIP TCLL 20.0 Plate Grip DOL 1.25 TIC 0.94 Vert(LL) -0.73 13-14 >595 360 MT20 244/190 TCDL 7.0 Lumber DOL 1.26 BC 0.94 Vert(CT) -1.3413-14 >321 240 MT18HS 244/190 BCLL 0.0 Rep Stress Incr YES WB 0.91 Horz(CT) 0.45 10 n/a n/a BCDL 10.0 Code FB02017/TP12014 Matrix -MS Wind(LL) 1.01 13-14 >428 240 Weight: 161 lb FT 20% LUMBER- BRACING- TOPCHORD 2x4 SP M 30 *Except' TOPCHORD Structural wood sheathing directly applied. 6-8: 2x4 SP M 31 BOTCHORD Rigid ceiling,directly applied or 2-2-0 oc bracing. BOTCHORD 2X4 SP M 30 WEBS 2x4 SP No.3 REACTIONS. (lb/size) 2�1386/0-8-0, 10=1386/0-8-0 Max Horz 2=-1 19(LC 10) Max Uplift 2=-846(LC 12), 10=-846(LC 12) FORCES. (lb) -Max. Comp./Max. Ten. -All forces 250 (lb) or less except when shown., TOPCHORD 2-3=-3338/2212, 3-4=-3134/2132, 4-5=-3441/2388, 5-7:=-5141/3470, 7i8=-6766/4,992, 8-9=-5629/3608, 9-10=-5945/3856 1 BOTCHORD 2-16=-1 989/3129,15-16=-1777/2918,14-15=-2177/3455,13-14=-3307�5216, 12-13=-3301/5421, 10-12=-3593/5659 WEBS 3-16=-527/480, 4-16=-413/669, 4-15=-535/785, 5-15=- 198/1876, 7-14=-851/667, 7-13=-962/1695,8-13�1260/1909, 8-12=-45/349,9-12.=-319/328 NOTES- 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-10; Vult=165mph (3-second gust) Vasd=128mph; TCE)L=4.2psf; BCDL3.0psf; h=12ft; B=591t; L=36ft; eave=5ft; Cat. 11; Exp C; Encl., GCpl=0.18; MWFRS (directional) and C-C Exterior(2) _ 1 -0-0 to 2-7-3,1 Interior(l) 2-7-3 to 37-0-0 zone;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) Provide adequate drainage to prevent water ponding. 4) All plates are MT20 plates unless otherwise Indicated. 5) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 6) * This truss has been designed for a live load of 20.Opsf on the bottom chord In all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 1 7) Bearing at joint(s) 10 considers parallel to grain value using ANSVTPI 1 angle to gral formula. Building designer should verify capacity of bearing surface. 8) Provide mechanical connection (by others) of truss to bearing plate capable of witrista.nding 100 lb uplift at joint(s) except gt=lb) 2=846,10=846. Walter P. Finn PE No.22839 MiTek USA, Inc. FL Cort 6834 6904 Parke East Blvd. Tampa FL 33610 Date: March 22,2018 I WARNING- Verify design parameters and RE40 NOTES ON THIS AND INCLUDED =1 cK REFE-15 PAGE 1011-7473 rev. IO/V3,2015 BEFORE USE. Design valid for use only with MF[ekO connectors. This design Is based only upon parameters sho", and Is for an Individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameieiis and properly Incorporate this design Into the overall bullding design. Bracing Indicated Is to prevent buckling of Individual truss web and/or chord m6mbers only. Additional temporary and permanent bracing Mek' Is always required for stability and to prevent collapse with possUe personal Injury and property damage. For general guidance regarding the fabrication, storage. dellvery� erection and bracing of trusses and truss systerns� seeANSIITPI I Quality Criteria, DSB-89 and BCSI Building Component 6904 Parke East Blvd. Safety Information available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA ! 22314. Tampa, FIL 33610 dob Truss Truss Type Qly Ply CARLTON 299 T13569612 M 11412 At SPECIAL 1 1 � Job Reference (optional) (;hambers Truss, inc., Fort Fierce, FL S. 130 s Nor 11 2018 ivii i er, HILIUSLUeb, 111G. 1 "U Mal 44 VU.V1.Q I 4V 10 rage I ID:kFvnsnOwY4[gZhO�_nM3lc6ylJ9g-o8K3sN5yiJGnKy2yo?67vt7ifO?3mYOGNUcwY]zYQn6 B-6-0 18-7-4 ?5!L6 -0 '-9-4 36-0-0 9ZLO-9 "00- 8-6-0 6-9-4 -I T 7-2-12 Scale 1:63.0 5x6 3x8 5x6 4.00 FIT 4 22 5 23 6 3X4 3 3A 7 21 24 2 7x8 MT18HS 10 8 ich 6 14 12 3x4 11 3x4 6 13 3x6 3x4 5x6 2.00 F1 _2 WO zz 13-8-0 18�7_4 24-6-0 1 36-0-0 :-6-0 5-2-0 4_ 1 -4 5-10-12 7-2-12 1 Plate Offsets (X,Y)-- 12:0-G-2,Edgel,[8:0-2-10,Edge],fl3:0-3-0,0-3-01 LOADING (pst) SPACING- 2-0-0 CS1. DEFL. In (loc) I/defl Ud PLATES GRIP TCLL 20.0 Plate Grip DOL 1.25 TC 0.61 Vert(LL) -0.58 11 >749 360 MT20 244/190 TCDL 7.0 Lumber DOL 1.25 BC 0.95 Vert(CT) -1.07 11-12 >402 240 MT18HS 244/190 BCLL 0.0 Rep Stress Incr YES WB 0.55 Horz(CT) 0.40 8 n1a n/a BCDL 10.0 Code FBC2017fTP]2014 Matrix -MS WInd(LL) 0.80 11 >541 240 Weight: 163 lb FT = 20% LIUMBER- TOP CHORD 2X4 SP M 30 BOT CHORD 2X4 SP M 30 WEBS 2x4 SP No.3 REACTIONS. (lb/size) 2=1386/0-8-0,8=1386/0-8-0 Max Horz 2=-1 41 (LC 10) Max Uplift 2=-846(LC 12), 8=-846(LC 12) FORCES. (lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOPCHORD 2-3=-3356/2159, 3-4=-3358/2292, 4-5=-2798/1921, 5-6=-4830/3137, 6-� 7-8=-5962/3751 BOTCHORD 2-14=-1935/3141, 13-14=-1610/2666,12-13=-2399/3926,11-12=-2400/,' 10-11 =-3499/5680, 8-1 0=-3492-/5669 WEBS 3-114=-404MI, 4-14=-507/777, 4-13=-1 51/409, 5-13=-1 376/890, 5-11 6-11 =-849/1449, 7-11 =-641/463 BRACING- TOPCHORD Structural wood sheathing directly applied or 2-7-2 oc pudins. BOTCHORD Rigid ceiling directly applied or 2-2-0 oc bracing. WEBS 1 Row at midpt 5-13 048, NOTES- 1 ) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-10; Vult=165mph (3-second gust) Vasd=128mph; TCDL--4 2psf- BCDLt3 - Opsf; h=12ft; B=59ft; L=36ft; eave=5ft; Cat. 11; Exp C; Encl., GCpi=0.18; MWFRS (directional) and C-C Exterior(2) -1 0'0 to'2 7 3 111 terior(l) 2-7-3 to 37-0-0 zone;C-C for 1=1.60 members and forces & MWFRS for reactions shown; Lumber DOL=1 60 plate grip D6L 3) Provide adequate drainage to prevent water ponding. 4) All plates are MT20 plates unless otherwise indicated. 5) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with a ny other live loads. 6) * This truss has been designed for a live load of 20.Opsf on the bottom chord In all area I s where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 7) Bearing at joint(s) 8 considers parallel to grain value using ANSIrrPI 1 angle to grain formula. Building designer should verify capacity of bearing surface. 8) Provide mechanical connection (by others) of truss to bearing plate capable of withstandling 100 lb uplift at joint(s) except at=lb) 2=846,8=846. Walter P. Finn PE No.22839 M!Tek USA, Inc. FL Cart 6634 6904 Parke East Blvd. Tampa Fl. 33610 Date: March 22,2018 ,A& WA G -Verify design parameters and READ NOTES ON THIS AND INCLUDED—E. REFERAME —GE 11411-7473 rev. 10103)2015 BEFORE USE. Design valid for use only with MITekO connectors. This design Is based only upon parameters shown, and Is for an IndivIdual building component, not a truss system. Before use. the building designer must verify the applicability of design parameters 6nd property Incorporate this design Into the overall buildingdesIgn. Bracing Indicated Is to prevent buckling of Individual truss web and/or chord members only. Additional temporary and permanent bracing MiTek* is always required for stability and to prevent collapse with possible personal Injury and property damage. For general guidance regarding the fabrication. storage, clellvery� erection and bracing of trusses and truss systems. seeANSIJTP1 I Quality Criteria, DSB-89 and BCSI Building Component 6904 Parke East Blvd. Safety Information available from Trim Plate Institute. 218 N. Lee StreetSulte 312. Alexandria. VA 22,314, Tampa, FL 33610 l,Job Truss Truss Type Qty Ply CARLTON 299 T13569613 M1 1412 A2 SPECIAL Job Reference (optional) �hambers Truss, Inc., Fort Pierce, FL 8 130 s Mar 112018 MiTek Industries, Inc. Thu Mar 22 09:07:52 2018 Page I ID:kFvnsnOwY419ZhO—nM3lc6ylJgg-GKuR4i6bTdOey6dgMidMR5gtzoLPVycQc8MT4BZYQn5 8-6-0 10 0 1 �5 18-0-0 22-2-0 24�6-00 89 4 36-0-0 "00- 8-6-0 -_4 4-2-0 4-2-0 2- 4--3--4 7-2-12 Scale 1:63.0 6x6 — 5x6 3x4 4.00 F1_2 4 5 6 46 7 3x4 3x4 Zz: 8 23 12 7 3X10 If 3x4 11 9 10 A CP 1? 6 15 14 7x8 IVITI SHS 3x6 3x4 11 5XB 2. 0 0 F1_2 4x10 z= 13-8-0 �816.02 22�'2-0 4 a2 36-0-0 5-2-0 B-6-0 �10 .0 4--;- �4 7-2-12 Plate Offsets (X,Y)-- [2:0-0-6, Edge], [9:0-2-10, Edgel I LOADING (psf) SPACING- 2-0-0 CS1. DEFL. in (loc) Well Ud PLATES GRIP TCLL 20.0 Plate Grip DOL 1.25 TC 0.58 Vert(LL) -0.55 11-12 >779 360 MT20 244/190 TCDL 7.0 Lumber DOL 1.25 BC 0.94 Vert(CT) -1.03 11-12 >419 240 MT18HS 244/190 BCLL 0.0 Rep Stress Incr YES WB 0.72 Horz(CT) 0.39 9 nfa n/a BCDL 10.0 Code FBC2017/TP12014 Matrix -MS Wind(LL) 0.77 11-12 >564 240 Weight: 167 lb FT = 20% LUMBER - TOP CHORD 2X4 SP M 30 BOT CHORD 2x4 SP M 30 WEBS 2x4 SP No.3 REACTIONS. (lb/size) 2=1386/0-8-0,9=1386/0-8-0 Max Horz 2=1 63(LC 11) Max Uplift 2=-846(LC 12), 9=-846(LO 12) FORCES. (lb) -Max. Comp./Max Ten. -All forces 250 (1b) or less except when shown. TOPCHORD 2-3=-3359/2129, 3-4=-2661/1761, 4-5=-2445/1690, 5-6=-3533/2289, 6-' BRACING - TOP CHORD Structural wood sheathing directly applied or 2-7-0 oc pudins. BOTCHORD Rigid ceiling directly applied or 2-2-0 oc bracing. 7-8=-5359/3351, 8-9=-5963/3683 1 BOTCHORD 2-15=-1909/3146,14-15=-1909/3146,13-14=-1826/3099, 12-16=-0016/0125' 11 -1 2=-3433/5679, 9-11 =-3426/5669 1 WEBS 3-15=0/295, 3-14=-807/566, 4-14=-354/620, 5-14=-916/58 I ' 5- 13=-26 1/668' 6-13=-588/1003,7-13=-2219/1408,7-12=-1137/1893,8-12=-628/443 1 NOTES- 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASC E 7-10; Vult=1 65mph (3-second gust) Vasd=1 28m ph; TCD IL--4.2psf-, BCD L � 3 Opsf; h= 1 2ft; B=5911t; L=36ft; eave=5ft; Cat. T' 11; Exp C; Encl., GCpi=0.18; MWFRS (directional) and C-C Exterior(2) -1-0-0 to 2-7-3, Interion(l) 2-7-3 to 37-0-0 zone;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOLI=1.60 3) Provide adequate drainage to prevent water ponding. 4) All plates are MT20 plates unless otherwise indicated. 5) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 6) * This truss has been designed for a live load of 20.Opsf on the bottom chord In all area's where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 1 7) Bearing at joint(s) 9 considers parallel to grain value using ANSI/TP1 1 angle to grain formula. Building designer should verify capacity of bearing surface. 8) Provide mechanical connection (by others) of truss to bearing plate capable of withstandling 100 lb uplift at joint(s) except flt=lb) 2=846,9=846. Walter P. Finn PE No.22839 MiTek USA, Inc. FL Cori 6634 6904 Parke East Blvd. Tampa FL 33610 Date: March 22,2018 WARNING- IArifyd.s19nparamfrs..dRE4D NOTES ONTHIS AND INCLUDED mica REFERAN-1 AGE M11-7473 rev. 1010312015 BEFORE USE. Design valid for use only with MITek0 connectors. This design Is based only upon parameters shown, and Is for an Individual building component not a truss system. Before use, the building designer must verify the applicability of design parameters and properly Incorporate this design Into the overall building design. Bracing Indicated Is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing MeW Is always required for stability and to prevent collapsevvith possible personal Injury and property ddmage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems. seeANSI/TPI I Quality Criteria, DSB-89 and RCSI Building Component 6904 Parke East Blvd. Safety Information available from Truss Plate Institute. 218 N. Lee Street, Suite 312. Alexandria. VA 22314. Tarnpa, FL 33610 4ob Truss Truss Type i Qty Ply CARLTON 29 T1 3569614 M1 1412 A3 SPECIAL Chambers Truss, inc., Fort Pierce, Jr-L 6.!30 b Ividl I 1 40 1 IS IVII I UK I I Idubulub, 11 %�. 1 1 Iu­ar2209:0i:Q4 401. .V. , ID:kFvnsnOwY4[gZhC�—nM3lc6ylJgg-CiOCVP7r EfLBPnXT7fqXWIDjcOvzsni3Srag4zYQn3 B-6-0 15-10-0 0-2-0 24-6-0 1 ' N 6 0; "00- 7-4-0 8-6-0 4-4-0 4-4-0 4W �O 7% Scale: 3116'=I' 4.00 F1 _2 5x6 5x6 4 5 5x6 5X8 6 5x6 WEI zz� 7 3x4 8 22 23 i 2 13 12 11 7x6 MTi 8HS 3x4 I I 9 10 ;� — 6 14 48 15 3x4 11 4x10 z: 3x5 2. 0 0 F1_2 6-0 13-8-0 LO 2 01 46-0 8-9 4 1 36-0-0 6-0 5-2-0 6 1 4. .0 4 1 1W 7-2-12 Plate Offsets (X,Y)-- [2:0-1-2, Edge], [3:0-4-0,0-3-01, f7:0-3-0, Edge], r9:0-2-1 0, Edge] LOADING (psf) SPACING- 2-0-0 CS1. DIEFL. in (loc) I/defl Ud PLATES GRIP TCLL 20.0 Plate Gri� DOL 1.25 TC 0.56 Vert(LL) -0.57 11-12 >761 360 MT20 244/190 TCDL 7.0 Lumber DOL 1.25 BC 0.94 Vert(CT) -1.05 11-12 >41 0 240 MT18HS 244/190 BCLI_ 0.0 Rep Stress Incr YES WB 0.74 Horz(CT) 0.40 9 n1a n/a BCDL 10.0 Code FBQ2017/TPI2014 Matrix -MS Wind(LL) 0.78 11-12 >551 240 Weight: 167 lb FT = 20% LUMBER- BRACING - TOP CHORD 2x4 SP M 30 TOPCHORD Structural wood sheathing directly applied or 2-6-15 oc puffins. BOTCHORD 2x4 SP M 30 BOTCHORD Rigid ceiling directly applied or 2-2-0 oc bracing. WEBS 2x4 SP No.3 WEBS I Row at midpt 6-13 OTHERS 2x4 SP No.3 REACTIONS. (Ib/sIze) 2=1386/0-8j,O, 9=1386/0-8-0 Max Harz 2=1 85(LC 11) Max Uplift 2=-846(LC 12), 9=-846(LC 12) FORCES. (lb) - Max. Comp./Max. Te n. All forces 250 (lb) or less except when shown. TOPCHORD 2-3=-3371/2103, 3-4=-2633/1707, 4-5=-2803/1850, 5-6=-2968/1899, 6-8=-5371/3290, 8-9=-5960/3616 BOTCHORD 2-15=-1886/3159 l4jl5=-1886/3153,13-14=-1343/2432,12-13=-2958/5 46, 11-12=-3368/56��191111=-3362/5666 WEBS 3-15=0/306, 3-14--866/626, 4-13=-285/671, 5-13=-379/702, 6-13=-2706i 659, 6-12=-1094/1946, 8-1'2=-611/435 NOTES- 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-10; Vult=165mph (3-second gust) Vasd=128mph; TCDL=4.2psf; BCDL=3,.Opsf; h=12ft; B=59ft; L=36ft; eave=5ft; Cat. ll;.Exp C; Encl., GCpi=0.18; MWFRS (directional) and C-C Exterior(2) -1-0-0 to 2-7-3, Interior(l) 2-7-3 to 37-0-0 zone;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOLL1.60 1 7 3) Provide adequate drainage to prevent water ponding. 4) All plates are MT20 plates unless otherwise indicated. 5) This truss has been designed for a 110.0 psf bottom chord live load nonconcurrent with any other live loads. 6) * This truss has been designed for allive load of 20.Opsf on the bottom chord In all area� where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and, any other members. 7) Bearing at joint(s) 9 considers parallel to grain value using ANSI[TPI I angle to grain formula. Building designer should verify capacity of bearing surface. 1 1 8) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) except at=lb) 2=846,9=846. Walter P. Finn PE No.22839 MiTak USA, Inc. FL Cort 6834 6904 Parke East Blvd. Tampa FL 33610 Date: March 22,2018 WARNING- Verify design parameters and RE4D NOTES ON THIS AND INCLUDED MrTEKREFERANCEfAGE1411-7473 rev. 10103)2015 BEFORE USE. Design valid for use only vA[h MlTeka coAnectors. This design Is based only upon parameters shown,land Is for an Individual building component not a Irrusssyslem. Before use, the building designer musiverify the applicability of design parameters and properly Incorporate this design Info the overall NAcHng design. Bracing Indicated Is to prevent bucMing of Individual truss wet) and/or chord members only. Additional temporary and permanent bracing MiTek' is always required for stability and to prevent collapse vAth possible personal Injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems� secANSI/TPI 1 QualIN Criteria, DSB-89 and BCSI Building Component 6904 Parke East Blvd. Safety Information avallable from Truss Plate Institute. 218 N. Lee Street, Suite 312, Alexandra. VA 22314. Tampa, FL 33610 �Job Truss Truss Type i Qty Ply CARLTON 299 T13569615 M1 1412 A4 SPECIAL 1 1 I Job Reference (optional) �hambers Truss, Inc., Fort Pierce, FL 8.130 s Mar 112018 MiTek Industries, Inc. Thu Mar 22 09:07:55 2018 Page 1 ID:kFvnsnOwY4l9ZhO-nM3lc6ylJgg-gvaailBTIYnCpZMklrB33jlNy,.?MCiFpsl6a7hWzy0n2 8-6-0 13-8-0 18-0-0 24-6-0 8_'-4 36-0-0 17-0- MOO 8-6-0 5-2-0 1 4-4-0 6-6-0 1-34 7-2-12 1-0-0 Scale: 3/16"=I' 4.00 FIT 5x6 3x4 24 25 5x6 3x6 5 5x6 WB-- 7 3x4 4 8 3x4 3 9 23 26 13 1011 14 7x8 MT18HS 12 3x4 I I 16 15 3x12 3X5 3x4 11 SX8 2.00 F1 _2 4x10 z� 6-0 1 13-8-0 1 4�6 0 14 1 36-0-0 I - 1 g8-6-0 5-2-0 IN—M, T 7-2-12 Plate Offsets (X,Y)-- f2:0-1-2, Edge], 18:0-3-0, Edge], fl 0:0-2-10, Edgel, [15:0-2-12,0-3-01 1 LOADING (psf) SPACINU- 2-0-0 CS1. DEFL. in (loc) I/defl Ud PLATES GRIP TCLL 20.0 Plate Grip' DOL 1.25 TC 0.60 Vert(LL) -0.61 13 >709 360 MT20 244/190 TCDL 7.0 Lumber DOL 1.25 BC 0.93 Vett(CT) -1.13 13 >383 240 MT18HS 244/190 BCLL 0.0 Rep Stress Incr YES WB 0.95 Horz(CT) 0.42 10 n/a n/a BCDL 10.0 Code FBC2017/TP[2014 1 Matrix -MS Wind(LL) 0.84 13 >513 240 Weight: 170 lb FT = 20% LUMBER - TOP CHORD 2X4 SP M 30 BOT CHORD 2X4 SP M 30 WEBS 2x4 SP No.3 OTHERS 2x4 SP No.3 REACTIONS. (lb/size) 2=13svo-8-b, 10=1386/0-8-0 Max Harz 2=-207(LC 1'0) Max Uplift 2=-846(LC 1 i 12), 10=-846(LC 12) BRACING- TOPCHORD Structural wood sheathing directly applied or 2-6-11 oc purlins. BOTCHORD Rigid ceiling directly applied or 2-2-0 oc bracing. WEBS 1 Row at midpt 7-14 FORCES. (lb) -Max. Comp./Max. Ten'. -All forces 250 (lb) or less except when shown. I TOP CHORD 2-3=-3361/2183 3-5= I L2660/1831, 5-6=-2458/1735, 6-7=-2481/1719, 7-9=-5407/3513, 9-1 0=-5950/376� 1 1 BOTCHORD 2-16=-1 931/3146, 15-16=-1 931/3146,14-1 5=-1 489/2515, 13-14=-3185/5191, 12-13=-3510/5666, ld,-12=-3504/5656 WEBS 3-16=0/315, 3-15=-799/546, 5-14=-344/260, 6-14=-731/1202, 7-1 4=-31201/2048, 7-13=-1 130/1972, 9-1 �=-559/376 NOTES- 1 ) Unbalanced roof live loads have beeh considered for this design. 2) Wind: ASCE 7-10; Vult=165m 3h (3-second gust) Vasd=1 28mph; TCDL=4.2psf; bUUL=3.Opsf; h=12ft; B=59ft; L=36ft; eave=5ft; Cat. 11; Exp C; Encl., GCpi=O.l 8; MWFRS� (directional) and C-C Exterior(2) -1 -0-0 to 2-7-3, Interlor(l) 2-7-3 to 18-0-0, Exterior(2) 18-0-0 to 21-7-3 zone;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=�1.60 plate grip DOL=1.60 3) All plates are MT20 plates unless othprwise Indicated. 1 4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 5) * This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and'any other members. 6) Bearing at joint(s) 10 considers parallel to grain value using ANSI/TPI I angle to grain foii1mula. Building designer should verify capacity of bearing surface. 1 7) Provide mechanical connection (by ot I hers) of truss to bearing plate capable of withstandiln 100 lb uplift atjoint(s) except at=lb) 2=846,10=846. Walter P. Finn PE No.22839 MiTek USA, Inc. FL Cert 6634 6904 Parke East Blvd. Tampa FL 336`10 Date: March 22,2018 AWARNING -Verify design parametersand"READ NOTES ON THIS ANDINCLUDEDMITEKREFERANCE PAGE M11-7473 rev. 10103,2015BEFORE USE. Design valid for use only with MITek9 connectors. This design Is based only upon parameters shown, and Is for an Individual building component not a truss system. Before use. the building cle�gner must verify the applicability of design parameters ana properly Incorporate this design Into the overall building design. Bracing Indicated Is to prevent buckling of Individual truss web and/or chord members only. Additional temporary and permanent bracing WOW Is always requIred for stability and to prevent collapse with possible personal Injury and property darnage. For general guidance regarding the tabficallon, storage, delivery, erection and bracing of trusses and truss systems, seeANSI/TPI I Quality Criteria, DSEI-69 and 8CSI Building Component 6904 Parke East Blvd. Safety Information available from TIM Plate Institute, 218 N. Lee Street. Suite 312. Aexandfla. VA 22311�1. Tampa, Fl. 33610 �Job Truss Truss Type Qty Ply CARLTON 2119 T11 3569616 M1 1412 A5 SPECIAL 7 Job Refe Truss, Inc., Fort Pierce, FIL 8.130 s Mar 112018 MiTek Industries, Inc. Thu Mar 22 09:07:56 2018 Page I .chambers I ID:kFvnsnOwY419ZhO_nM3lc6ylJgg-958yw5g5Wsv3RjwwbYilcxrYhPiRRi ?XmKhDZZYQnl 8-6-0 1 8-0 15---2_0 18-0-0 24-6-0 36-0-0 H00- 8-6-0 i 4-4-0 6-6-0 i i 7-2-12 Scale 1:61.9 4.00 FIT SX6 6 3x4 !::m 24 25 5x6 3x6 5 5x6 WB 3x4 4 8 3x4 zz� 9 26 1 13 1 2 1 14 7x8 MT18HS 12 3x4 11 10 11 J: 6 16 15 4x10 3x5 3x4 5x8 = 2.00 FIT 4x10 zz 80 L5 0 0 14- 4-60 8;14 L6 36-0-0 N-20 -_� N 1 N 6 4 7-2-12 Plate Offsets (X,Y)-- 12:0-1-2, Edge], 118:0-3-0, Edge], [10:0-2-10, Edgel, [15:0-2-12,0-3-01 LOADING (psf) SPACING- 2-0-0 CS1. DEFL. in (loc) I/defl Ud PLATES GRIP TCLL 20.0 Plate Grl� DOL 1.25 TC 0.60 Vert(LL) -0.61 13 >709 360 MT20 244/190 TCDL 7.0 Lumber DOL 1.25 BC 0.93 Vert(CT) -1.13 13 >383 240 MT18HS 244/190 BCLL 0.0 Rep Stress Incr YES WB 0.95 Horz(CT) 0.42 10 n/a n/a BCDL 10.0 Code FBC2017/TP12014 Matrix -MS Wind(LL) 0.84 13 >513 240 Weight: 170 ib FT = 20% LUMBER - TOP CHORD 2X4 SP M 30 BOT CHORD 2X4 SP M 30 WEBS 2x4 SP No.3 OTHERS 2x4 SP No.3 REACTIONS. (lb/size) 2=1386/0-8�0, 10=1386/0-8-0 Max Horz 2=-208(LC i ' 0) Max Uplift 2=-846(LC 12), 10=-846(LC 12) i FORCES. (lb) - Max. Comp./MaA. I ei i. - M foices 250 (lb) or less except when shown. TOP CHORD 2-3=-3361/2183, 3-5---L2660/1831, 5-6=-2450/1730, 6-7=-2472/1713, 7- 9-1 0=-5950/3764 1 BOTCHORD 2-16=-1 931/3146, 15-16=-1 931/3146, 14-15=-1 489/2515, 13-14=-3184 12-13=-351015666, 10-12=-3504/5656 WEBS 3-16=0/315, 3-15=-799/546, 5-14=-355/272, 6-14=-743/1219, 7-14=-31 7-13=-1 130/1972, 9-1 6=-560/375 NOTES- i BRACING- TOPCHORD Structural wood sheathing directly applied or 2-6-11 oc purlins. BOTCHORD Rigid ceiling directly applied or 2-2-0 oc brading. WEBS 1 Row at midpt 7-14 90, I ) Unbalanced roof live loads have been considered for this design. 1 2) Wind: ASCE 7-10; VUlt=165mph (3-second gust) Vasd=128mph; TCDL=4.2psf; BCDL=3.upsT; n=12R; t3=59ft; L=36ft; eave=51t; Cat. 11; Exp C; Encl., GCpi=0.18; MWFRS1 (directional) and C-C Exterior(2) -1-0-0 to 2-7-3, Int6rior(l) 2-7-3 to 18-0-0, Exterlor(2) 18-0-0 to 21-7-3 zone;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1�1-60 plate grip DOL=1.60 3) All plates are MT20 plates unless otherwise indicated. 4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 5) * This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas rhere a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and �any other members. 6) Bearing at joint(s) 10 considers parallel to grain value using ANSl[TP1 11 angle to grain formula, Building designer should verify capacity of bearing surface. I 'kg 100 lb uplift at joint(s) except at=lb) 7) Provide mechanical connection (by others) of truss to bearing plate capable of withstand! 2=846,10=846. 1 Walter P. Finn PE No.22839 MiTek USA, Inc. FL Cert 6634 6904 Parke East Blvd. Tampa FL 33610 Date: March 22,2018 ja WARNING -Vedly design parameters and'RE4D MOTES ON THIS AND INCLUDED NITEKREFERANCEPAI GEM11-7473mv. 1010312015 BEFORE USE. Design valid for use only with MITekO conr�ectors. This design Is based only upon parameters shown, and Is for an Individual building component, not a truss system. Before use. the building designer must verify the applicability of design parameters and property Incorporate this design Into the overall building design. Bracing Indloaled Is to pfbvent buckling of Individual truss web and/or chord memb4ars only. Addlional temporary and permanent bracing MOW Is always required for stability and to pre;v6nt collapse with possible personal Injury and property dambge. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, seeANSIjTP1 I Quality Criteria, DSB-89 and RCSI Building Component Safety Information available from Truss Plate Institute, 218 N. Lee Street, Suite 312. Alexandrict, VA 2231 �. 6904 Parke East Blvd. Tampa, FL 33610 jJob Truss Truss Type Qty Ply CARLTON 299 T13569617 M 11412 ATA COMMON 7 1 Job Reference (optional) Chambers Truss, Inc., Fort Pierce, FL 8.130 s Mar 112018 MiTek Industries, Inc. Thu Mar 22 09:07:67 2018 Page 1 ID:kFvnsnOwy4lgZhO_nM3lc6ylJ9g-dHhK7RAjHgiw2tV69FDX8BNkPp6jAEjgIQ3EmPzYQnO B-1-1 12- 12_2 18_0_0 22-1-14 27 10 15 36-0-0 _0 V0 4 Voo 5 8-1-1 _9_� 4-1-14 4-1-14 _9_1 8-1-1 . -0 Scale = 1:61.0 4.00 FIT 5x6 3x4 11 3x4 11 626 27287 3x6 7;�- 5 3x6 3x4 4 B 3x4 a . 3 9 24 29 10 11 6 17 16 15 30 31 14 13 12 3x4 11 4x6 3X8 3x8 46 3x4 11 3X8 3x8 13-10-2 22-1-14 2 10 -115 36-0-0 5-9-1 8-1-1 Plate Offsets (X,Y)-- T2:0-8-6,0-0-81,JlO:0-8-6,0-0-8] I T3-12 LOADING (psf) SPACING- 2-0-0 CS1. DEFL. in (loc) I/defl Ud PLATES GRIP TCLL 20.0 Plate Grip DOL 1.25 TC 0.53 Vert(LL) -0.28 14-15 >999 360 MT20 244/190 TCDL 7.0 Lumber DOL 1.25 BC 0.67 Vert(CT) -0.59 14-15 >730 240 BCLL 0.0 Rep Stress Incr YES WB 0.60 Horz(CT) 0.14 10 n1a n/a BCDL 10.0 Code FBC2017/TPI2014 Matrix -MS Wind(LL) 0.34 14-15 >999 240 Weight: 172 lb FT = 20% LIUMBER- BRACN%D TOPCHORD 2X4 SP M 30 TOP CHO Structural wood sheathing directly applied or 3-2-15 oc puffins. BOTCHORD 2x4 SP M 30 BOTCHORD Rigid ceiling directly applied or 5-2-0 oc bracing. WEBS 2x4 SP No.3 REACTIONS. (lb/size) 2=1436/0-8-0, 10=1436/0-8-0 Max Horz 2=-208(LC 10) Max Uplift 2=-796(LC 12), 10=-796(LC 12) FORCES. (lb) -Max. Comp./Max. Ten. -All forces 250 (lb) or less except when shown. TOPCHORD 2-3=-3544/2053, 3-5=-2824/1651, 5-6=-2817/1766, 6-7=-2817/1766, 7-9---2824/1651, 9-10=-3544/2053 1 BOTCHORD 2-17=-1812/3323,15-17=-1812/3323,14-15=-997/2104,12-14=-1826/3323, 10-12=-1826/3323 1 WEBS 6-14=-569/1002, 7-14=-299/279, 9-14=-783/581, 9-12=0)e 1 1, 6- 1 5=-569/ UO2, 5-1 5=-300/279, 3-15=-782/581, 3-17=0/271 NOTES- 1 ) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-10; Vult=1 65mph (3-second gust) Vasc1=1 28mph; TCDL=4.ZPST; lJUIJI_-3.0psf; h=1 2ft; B=59ft; L=36ft; eave=5ft; Cat. 11; Exp C; Encl., GCpi=0.18; MWFRS (directional) and C-C Exterior(2) -1-0-0 to 2-7-3, Int I erior(l) 2-7-3 to 18-0-0, Exterlor(2) 18-0-0 to 21-7-3 zone;C-C for members and forces & MWFRS for reactions shown; Lumber DOLJ,1.60 plate grip DOL=1.60 3) 100.01b AC unit load placed on the top chord, 18-0-0 from left end, supported at two points, 6-0-0 apart. 4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 5) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas phere a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members, with BCDL = 1 O.Opsf. 6) Provide mechanical connection (by others) of truss to bearing plate capable of withstandi,hg 100 lb uplift at joint(s) except at=lb) 2=796,10=796. 1 Walter P. Finn PE No.22839 MiTek USA, Inc. FL Cori 6634 6904 Parke East Blvd. Tampa FL 33610 Date: March 22,2018 ,&WARNING - I/efflyalesign parameters and READ NOTES ON THIS AND INCLUDEDMITEKREFERAMCE PAGE M11-7473 rev. 1010352015 BEFORE USE Design valid for use only with M]Tek@) connectors. This design Is based only upon parameters shown, ci�d Is for an Individual building component not a truss system. Before use. the building designer must verily the applicability of design parameters and properly Incorporate this design Into the overall building design, Bracing Indicated Is to prevent buckling of Individual truss web and/or chord memb�rs only. Additional temporary and permanent bracing MiTek' Is always required for stability and to prevent collapse with possible personal Injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss sYsIeM sCeANSI/TPI I Quality Criteria, DSB-89 and BCSI Building Component 6904 Parke East Blvd. Safety Information available from Trim Plate Institute, 218 N. Lee Street, Suite 312, Mexandria, VA 22,31 Tampa, FL 33610 �Job Truss Truss Type city Ply CARLTON 29 TI 3569618 ATB COMMON I Job Referenc nnnnn7CDnn40 0 i Chambers Truss, inc., Fori Pierce, FL U.i ov S ar 1 i Zv I e n us nes, nc. I— �i U ID:kFvnsnOwY4l9ZhO_nM3lc6y]Jgg-5UFjKnBL2Tgngl4ijzkmhMwyeDWlvgpl-4pnlrzYQn? 8-1-1 18_0_0 22-1-14 2�190-15 36-0-0 0 �11 Vol 8-1-1 5_ 4-1-14 4-1-14 B-1-1 V� Scale = 1:60.9 4.00FI-2 SX6 3x4 11 3x4 11 "X4 'I 3x6 5 2 27 28297 627 3x6 Z�- 3X4 4 8 3x4 �8� 9 3 _--_550� 25 30 2 10 11 t2 16 6 18 17 16 Is 31 32 14 13 12 6 3x4 11 3x6 = 6x8 6X8 = 3x6 3x4 11 3x5 36 13-10-2 11, 21-10-0 4 36-0-0 &9-1 %719011 6-8-0 OW4 8-1-1 LOADING (psf) SPACING- 2-0-0 cSI. DEFL. in (loc) I/defl Ud PLATES GRIP TOLL 20.0 Plate Grip DOL 1.25 TC 0.37 Vert(U-) -0.10 18-21 >999 360 MT20 244/190 TODL 7.0 Lumber DOL 1.25 BC 0.40 Vert(CT) -0.22 18-21 >844 240 BCLI_ 0.0 Rep Stress Incr YES WB 0.68 Hor-z(CT) 0.02 15 n/a n/a BCDIL 10.0 Code FBC2017/TP12014 Matrix -MS Wind(LL) 0.15 18-21 >999 240 Weight: 172 lb FT = 20% LUIMBER- BRACING - TOP CHORD 2x4 SP M 30 TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins. BOTCHORD 2x4 SP M 30 BOTCHORD Rigid ceiling directly applied or 6-0-0 oc bracing. WEBS 2x4 SP No.3 WEBS 1 Row at midpt 6-14 REACTIONS. All bearings 0-8-0. (lb) - Max Harz 2=-208(LC 10) Max Uplift All uplift 100 lb or less at Joint(s) 15 except 2=-433(LC 12), 14=- 66(LC 12), 1 0=-240(LC 12) Max Grav All reactions 250 lb or less at joint(s) except 2=687(LC 21), 14= 635(LC 1), 1 0=399(LC 22), 15=349(LC 17) FORCES. (lb) -Max. Comp./Max. Ten. -All forces 250 (lb) or less except when shown. TOP CHORD 2-3=-1239f757, 3-5=-437/333, 5-6=-432/448, 6-7=-272/773, 7-9=-3761778, 9-1 0=-334/220 BOTCHORD 2-18=-587/1178,16-18=-587/1178,12-14=-1 88/281, 10-12=-1 88/281 WEBS 6-14=-1096/683, 7-14=-303/281, 9-14�853/614, 9-12=-13/307,6-16=-501/665, 5-16=-302/279, 3-16=-890/616, 3-18=-1 6/332� 1 NOTES- 1 ) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-10; Vult=165mph (3-second gust) Vasd=128mph; TCDL=4.L'psl; t5UIJL=d.qpsf; h=12ft; B=59ft; L=36ft; eave=5ft; Cat. 11; Exp C; Encl., GCpi=0.18; MWFRS (directional) and C-C Exterior(2) -1-0-0 to 2-7-3, Interior(l) 2-7-3 to 18-0-0, Exterior(2) 18-0-0 to 21-7-3 zone;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1. ' 0 plate girp DOL=1.60 3) 100.011b AC unit load placed on the top chord, 18-0-0 from left end, supported at two pointsr6-0-0 apart. 4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 5) * This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas w1kere a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members, with BCDL = 10.Opsf. 6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 15 except at=lb) 2=433,14=866.10=240. i Walter P. Finn PE No.22839 Mi rek USA, Inc. Fl. Cert 6634 6904 Parke East Blvd. Tampa FL 33810 Date: March 22,2018 WARNING- Verify design parameters and READ NOTES ON THIS AND INCLUDED MIT5KREFERANCE PAGE M11­7473 rev. 1010312015 BEFORE USE. Design valid for use only with MiTekg connectors. This design Is based only upon parameters shown ancills for an Individual building component, not a truss system. Before use. the building designer must vedfy the applicability of design parameters �nd pioperly incorporate this design into the overall building design. Bracing Indicated Is to prevent buckling of Individual truss web and/or chord mernbers'only. Additional temporary and permanent bracing MiTek* Is always required for stability and to prevent collapse with possible personal Injury and property darnog6. For general guidance regarding the fabricatiort storage. delivery, erection and bracing of trusses and truss systems, seeANSI/TPI I Quality CrIt6ria, DSB-89 and BCSI Building Component 6904 Parke East Blvd. Safety Information available from Truss Plate Institute, 218 N. Lee Street Suite 312, Alexandria, VA 22314. 1 Tampa, FL 33610 Job Truss Truss Type City Ply CARLTON 29 T1 3569619 M 11412 ATC COMMON I Job eference (optional) �;narnl)ers I russ, Inc., 1--Orl Melce, rL C�. 2 6 3X6 = 0. IOU b IVId[ I I eV 10 IVII I er, I I IUUb1IWb, H IU. I I JU IV1dI 44 UuvVl.ou 4V 10 rduv I ID:kFvnsnOwY4[gZhO—nM3lc6ylJgg-Zgp5Y78—pnHeI BfVGgF?EZT70dsXe73SDkYLqHzYQn- 18-0-0 � . 22-1-14 1 27-10-15 36-0-0 37-0-0 5-9-1 4-1-14 4-1-14 4.00FI-2 6x6 6 3 3x4 I 3x4 11 X4 11 28 3x6 5r 5 2627 297 3x4 4 3 25 17 � 31 18 16 15 3X4 11 3x6 = 6x8 = 32 — 13 14 6x8 = 3x6 3X6 zz� 8 3X4 Z-- 9 12 3x4 11 30 Scale = 1:60.9 10 11 �2 tz�IC6 6 3X5 = 8-1- 13-10-2 5 -1 22 7 27�180 15 36-0-0 �; 11 4 i �_J _1 I _ _ 1 5-9-1 1 — -2 111'�Ml - 14 8-1-1 6 O_h LOADING (pst) SPACING- 2-0-0 CS1. DEFL. in (loc) I/defl Ud PLATES GRIP TCLIL 20.0 Plate Grip DOL 1.25 TC 0.37 Vert(LL) -0.10 18-21 >999 360 MT20 244/190 TCDL 7.0 Lumber DOL 1.25 BC 0.40 Vert(CT) -0.22 18-21 >844 240 BCLL 0.0 Rep Stress Incr YES WB 0.68 Horz(CT) 0.02 15 n/a n1a BCDL 10.0 Code FBC2017ITP]2014 Matrix -MS Wind(LL) 0.15 18-21 >999 240 Weight: 172 lb FT = 20% LIUMBER- BRACING- TOPCHORD 2x4 SP M 30 TOPCHORD Structural wood sheathing directly applied or 6-0-0 oc purlins. BOTCHORD 2x4 SP M 30 BOTCHORD � Rigid ceiling directly applied or 6-0-0 oc bracing. WEBS 2x4 SP No.3 WEBS 1 Row at midpt 6-14 REACTIONS. All bearings 0-8-0 except at=length) 14=0-1 1-5. (lb) - Max Horz 2=-208(LC 10) Max Uplift All uplift 100 lb or less at joint(s) 15 except 2=-433(LC 12), 14= MaxGrav All reactions 260 lb or less atjoint(s) except 2=687(LC 21), 14:=1635(LC -866(LC 12), 10=-240(LC 12) 1), 10=399(LC 22), 15=349(LC 17) FORCES. (lb) -Max. Comp./Max. Ten. -All forces 250 (lb) oriess except when shown. TOPCHORD 2-3=-12391757,3-5=-437/333,5-6=-432/448,6-7=-272[773,7-9=-376/778, 9-1 0=-334/220 BOTCHORD 2-18=-587/1178, 16-18=-587/1178, 12-14=-1 88/281, 10-12=-1 88/281 WEBS 6-14=-1 096/683, 7-14=-303/281, 9-14�853/614, 9-12=-1 3/307, 6-16=-501/665 5-16=-302/279, 3-16=-890/616, 3-18=-1 6/332 1 NOTES- 1 ) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-10; Vult=165mph (3-second gust) Vasd=128mph; TCDL=4.2ps1; t5UIJL=3.0psf; h=12ft; B=59ft; L=36ft; eave=5ft; Cat. 11; Exp C; Encl., GCpi=0.18; MWFRS (directional) and C-C Exterlor(2) -1-0-0 to 2-7-3, In erior(l) 2-7-3 to 18-0-0, Exterior(2) 18-0-0 to 21-7-3 zone;C-C for members and forces & MWFRS for reactions shown; Lumber DOLt.60 plate grip DOL=1.60 3) 100.Olb AC unit load placed on the top chord, 18-0-0 from left end, supported at two points, 6-0-0 apart. 4) This truss has been designed for a 10.0 pst bottom chord live load nonconcurrent with any other live loads. 5) * This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas1where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members, with BCDL = 10.Opsf. 1 6) Provide mechanical connection (by others) of truss to bearing plate capable of withstand ng 100 lb uplift at joint(s) 15 except at=lb) 2=433,14=866.10=240. 1 Walter P. Finn PE No.22839 MiTek USA, Inc. FL Carl 6634 6904 Parke East Blvd. Tampa FL 33610 Date: March 22,2018 WARNING - Verify design parameters and READ AforEs ON THIS AND INCLUDED MITEK REFERANCE P AGE M11-7473 rev. 10103)2015 BEFORE USE. , Design valid for use only with MITek8 connectors. INs design Is based only upon parameters shown, and Is for an Individual building component, not a truss system. Before use. the building designer must vedfy the applicability of design parameters arid properly Incorporate this design Into the overall buildIng design. Bracing Indicated Is to prevent buckling of Individual truss web and/or chord members only. Additional temporary and permanent bracing MeW Is always required for stability and to prevent collapse with possible personal Injury and property damage. For general guidance regarding the fobficatiom storage. delivery, erection and bracing of trusses and truss systems. seeANSIJTPI 1 Quality , Criteria, DSB-89 and BCSI Building Component 6904 Parke East Blvd. Safety Information available from Truss Plate Institute, 218 N. Lee Street, Suite 312. Alexandria. VA 223� 4. Tampa, FL 33610 1 I Job Truss Truss Type Qty Ply CARLTON 21111 T13569620 M11412 BHA COMMON 1 Job Rate Chambers Truss, Inc., Fort Pierce, FL 8-0-0 4-0-0 . 2-0-0 8.130 s mar 11 2018 miieK industries, Inc. it1umar2zu9:u8:uu2u1b vagel ID:kFvnsnowY4l9ZhO—nM3lc6ylJgg-IsNTISCca4PVvKEhqOmEmn?CeOgGNYvbSOluLkzYQmz 16-0.0 1 24-0-0 2 -0-0 ' 2-0-0 ' 2-0-0 5x6 ME 4-0-0 8-0-0 Scale: 3/16"=I' 7xl 0 MT1 8HS �1� 7 16 5 18 7x10 4.00FI-2 3x6 3 8 0 17 20 2 21 2 C� 2 Al 28 27 26 25 24 23 3X6 11 4x6 6x8 6X8 3X6 11 3X5 3x6 3x6 15-6-0 22-10-15 36-0-0 No-_Oo 7-6-0 7-4-15 T-10 1-0 8-0-0 —1 Plate Offsets (X,Y)-- [2:0-0-2, Edge], [3:0-3-8, Edge], [11:0-3-0,0-3-01, [20:0-3-8, Edge], 1911:0-2-8, Edge], [25:0-3-8,0-3-01 LOADING (psf) SPACING- 2-0-0 CS1. DEFL. In (loc) I/defl L/d PLATES GRIP TCLL 20.0 Plate Grip DOL 1.25 TC 0.73 Vert(LL) -0.14 28-31 >999 360 MT20 244/190' TCDL 7.0 Lumber DOL 1.25 BC 0.56 Vert(CT) -0.25 23-34 >619 240 MT18HS 244/190 BCLL 0.0 Rep Stress Incr NO WB 0.83 Horz(CT) 0.04 21 n1a. n/a. BCDL 10.0 Code FBC2017/TP12014 Matrix -MS Wind(LL) 0.2028-31 >909 240 Weight: 206 1b FT = 20% LIUMBER- TOP CHORD 2X4 SP M 30 BOT CHORD 2x4 SP M 30 WEBS 2x4 SP No.3 REACTIONS. All bearings 0-8-0 except Ot=length) 25=0-1 1-5. (lb) - Max Horz 2=-208(LC 6) MaxUplift All uplift 100 lb or less at joint (s) except 2=-583(LC 8), 26=-1 E 21 =-455(LC 8) Max Grav All reactions 250 lb or less at joint(s) except 2=983(LC 13), 2E 21=757(LC 14) FORCES. (lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOPCHORD 2-3=-2242/1142, 20-21 =_ 1473/724, 3-4=-213/718, 4-6=-213/718, 6-8=-2 8-10=-213f718, 10-11=-213/718,11-13=-213/718,13-15=-2131718,15-1 17-19�87/610' 19-20=-87/610, 3-5=-1 99/422, 5-7=-1 12/391, 7-9=-33/3z 16-18=-67/301, 18-20=-206/363 BOTCHORD 2-2B=-971/2236, 26-28=-922/2090,25-26=-855/521, 23-25=-516/1204,: WEBS 8-26=-1333/1008, 17-25=-979/756, 3-28=-419/1254, 3-26=-3236/1698, � 20-25=-2385/1201, 9-1 0=-706/569, 6-7=-307/241, 15-16=-462/372, 18-1 BRACING - TOP CHORD Structural wood sheathing directly applied or 4-2-12 oc purlins. BOTCHORD Rigid ceiling directly applied or 6-0-0 oc bracing. WEBS I Row at midpt 20-25 2 Rows at 1/3 pts 3-26 JOINTS 1 Brace at Jt(s): 8, 4, 14, 16, 18 (LC 8), 25=-1 259(LC 8), =291 1 (LC 13), 25=2457(LC 14), 3/718, '=-213/71 8. I, 12-14=0/257, 1-23=-569/1344 )-23=-458/1210, i=-497/418 NOTES- 1) Unbalanced root live loads have been considered for this design. 2) Wind: ASCE 7-10; Vult=165mph (3-second gust) Vasd=128mph; TCDIL=4.2psf; BCDL�3.Opsf; h=12ft; B=59ft; L=36ft; eave=5ft; Cat. 11; Exp C; Encl., GCpi=0.18; MWFRS (directional); Lumber DOL=1.60 plate grip DOL=1!60 3) Provide adequate drainage to prevent water ponding. 4) All plates are MT20 plates unless otherwise indicated. 6) All plates are 3x4 MT20 unless otherwise indicated. 6) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 7) * This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 8) Provide mechanical connection (by others) of truss to bearing plate capable of withstan�lng 583 lb uplift at joint 2, 1557 lb uplift at joint 26, 1259 1b uplift at joint 25 and 455 lb uplift at joint 21. 9) Girder carries hip end with 8-0-0 end setback. 10) Graphical purlin representation does not depict the size or the orientation of the purlin along the top and/or bottom chord. 11) Hanger(s) or other connection device(s) shall be provided sufficient to support concentrated load(s) 967 lb down and 461 lb up at 28-0-0, and 967 lb down and 461 lb up at B-0-0 on bottom chord. The design/selection' of such connection device(s) is the responsibility of others. I 12) In the LOAD CASE(S) section, loads applied to the face of the truss are noted as front I(F) or back (B) I Walter P. Finn PE No.22839 MiTek USA, Inc. Fl. Cert 6834 6904 Parke East Blvd. Tampa Fl. 33610 Date: March 22,2018 ah &EI'SilmStandard ,&WARNING -Verify design parameters and READ NOTES ON THIS AA[DINCIUDEDMiTEKREFERANCE'PAGEMil-7473 rev. 1010312015 BEFORE USE Design valid for use only vAth MITekS connectors. This design Is based only upon parameters shownJ and Is for an Individual building component not a truss system. Before use, the building designer must verify the applicability of design parameters dnd properly Incorporate this design Into the overall building design. Bracing Indicated Is to prevent buckling of Individual truss web and/or chord members only, Additional temporary and permanent bracing MiTek* is always required for stability and to prevent collapse vAth possible personal Injury and property damage. For general guidance regarding the fabrication. storage, delivery, erection and bracing of busses and truss systems, seeANSIITPI I Quallt� Criteria, DSB-89 and BCSI Building Component 6904 Parke East Blvd. Safety Information available from Truss Plate Institute, 218 N. Lee Street Suite 312, Alexandria. VA 22 il 4. Tampa, FIL 33610 �Job Truss Truss Type City Ply CARLTON 299 T13569620 BHA COMMON I Job Refer Phambers Truss, Inc., Fort Pierce, FL 8.130 s Mar 112018 MiTek Industries, Inc. Thu Mar 22 09:08:01 2018 Page 2 ID:kFvnsnOwY419ZhC�—nM3lc6ylJgg-V3xrzoDELOXMXUptO5HTJ—YNOQVV6?8kg2lSuAzYQmy LOAD CASE(S) Standard 1) Dead + Roof Live (balanced): Lumber Increase=1.25, Plate Increase=1.25 Uniform Loads (plf) Verl: 1-3=-54, 20-22=-54, 28-29=-20, 23-28=-47(F=-27), 23-32=-20, 3-12=-126(F=-72)' Concentrated Loads (lb) Vert: 28=-641 (F) 23=-641 (F) 12-20=-126(F=-72) WARNING- Wrilydesign parameters and READ NOTES ON THIS AND INCLUDED MITEKREFERANCE PAGE M11-7473rev. 10103)2016 BEFORE USE. Design valid for use only Wth MIT06 connectors. This design Is based only upon parameters shown,and Is for an Individual building component not a truss system. Before use, the building designer must vedfy the applicability of design parameters chat properly Incorporate this design Into the overall bullcring design. Bracing Indicated Is to prevent buckling of Individual truss web and/or chord members only. Additional temporary and permanent bracing MeW is always required for stability and to prevent collapse Mth possible personal Injury and properly darlriage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems. SeeANSI/TP1 I Quality, Criteria, DSB-89 and BCSI Building Component 6904 Parke East Blvd. Safety Information available from Truss Plate Institute, 218 N. Lee Street, Suite 312. AJexandfla, VA 22,1. 14. Tampa, FL 33610 Job Truss Truss Type oty Ply CARLTON 299 T13569621 M 11412 GRA HIP 'Job Reference (optional) !-;namDers i russ, mc., r-ori merce, r-L 2 6 3X5 = 13-8-0 7-10-0 5x8 MT1 8HS 4.00 F1 —2 3x4 11 3 22 23 24 25 4 26 ID:kFvnsnOwY4l9ZhO—nM3lc6ylJ9g-zFVDA8Es6ifD9eO4xppirC5YMqocrRHuvin?QczYQmx -0 4-4-0 27 �X5 8 = 28 15 34 14 13 35 36 3x4 11 46 = 6x12 = 37 38 0-0 5x8 MT1 8HS 3x4 11 629 30 31 32 33 7 12 391, 40 10, 6x12 = 4x6 3x4 11 Scale = 1:61.9 8 9 9 ! 61 3x5 Plate Offsets (X,Y)-- [3:0-5-4,0-2-81, J5:0-4-0,0-3-0],17:0-5-4,0-2-81 I LOADING (pst) SPACING- 2-0-0 CSI. IDEFIL. in (loc) I/clefl Lid PLATES GRIP TCLL 20.0 Plate Grip DOL 1.25 TC 0.71 Vert(LL) -0.21 12-13 >999 360 MT20 244/190 TCDL 7.0 Lumber DOL 1.25 BC 0.76 Vert(CT) -0.44 12-13 >609 240 MT18HS 244/190 BCLL 0.0 Rep Stress Incr NO WB 0.84 Horz(CT) O�06 8 n/a n/a BCDL 10.0 Code FBC2017/TPI2014 Matr1x-MS Wind(LL) 0.22 10-21 >999 240 Weight: 161 lb FT = 20% LIUMBER- TOP CHORD 2X4 SP M 30 BOT CHORD 2X4 SP M 30 WEBS 2x4 SP No.3 *Except* 4-13,6-12: 2x6 SP No.2 REACTIONS. (Ib/size) 2=398/0-8-0,13=3546/0-8-0, 8=1252/0-8-0 Max Horz 2=-97(LC 6) Max Uplift 2=-292(LC 8),13=-2107(LC 8), 8=-799(LC 8) Max Grav 2=417(LC 17), 13=3546(LC 1), 8=1 256(LC 18) BRACING- TOPCHORD Structural wood sheathing directly applied or 3-4-6 oc purlins. BOTCHORD Rigid ceiling directly applied or 5-7-0 oc bracing. WEBS 1 Row at midpt 3-13,5-13 FORCES. (lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 2-3=-369/211, 3-4=-1 158/2051, 4-5=-1 158/2051, 5-6=-2318/1425, 6-7=-2318/1425, 7-8=-2981/1789 BOTCHORD 2-15=-196/311, 13-15=-201/342,12-13=-246/452, 10-12=-1588/2818, 8-10=-1578/2786 WEBS 3-15=-1 81/648, 3-13=-2568/1568, 4-13=-640/587, 5-13=-2900/1855, 5-12=-1 172/2196, 6-12=-6111569, 7-12=-558/375, 7-10=-184/651 1 NOTES - I ) Unbalanced root live loads have been considered for this design. 2) Wind: ASCE 7-10; Vult=1 65mph (3-second gust) Vasc1=1 28mph; TCDL.=4.2psf; BCDL10psf; h=1 2ft; B=59ft; L=36ft; eave=5ft; Cat. 11; Exp C; Encl., GCpi=O.l 8; MWFRS (directional); Lumber DOL=1.60 plate grip DOL=1.60 3) Provide adequate drainage to prevent water ponding. 4) All plates are MT20 plates unless otherwise indicated. 5) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with aby other live loads. 6) * This truss has been designed for a live load of 20.Opsf on the bottom chord In all areaswhere a rectangle 3� 6-0 tail by 2-0-0 wide will fit between the bottom chord and any other members, 1 7) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 292 lb uplift at joint 2, 2107 lb uplift at joint 13 and 799 lb uplift at joint 8. 8) Hanger(s) or other connection device(s) shall be provided sufficient to support concentr"ted load(s) 137 lb down and 301 lb up at 7-10-0, 103 lb down and 170 lb up at 10-0-12, 103 lb down and 170 Ito up at 12-0-12, 103 lb down and 170 lb up at 14-0-12, 103 Ito down and 170 lb up at 16-0-12,103 lb down and 170 lb up at 18-0-12 ' 103 lb down and 170 lb up at 19-11-4,103 lb down and 170 lb up at 21-11-4,103 lb down and 170 lb up at 23-11-4, and 103 lb down and 170 lb upi at 25-11-4, and 137 lb down and 301 lb up at 28-2-0 on top chord, and 340 lb down and 223 lb up at 7-10-0, 77 lb down and I lb up at 8-0-12, 77 lb down and 1 lb up at 10-0-12, 77 lb down and I lb up at 12-0-12, 77 lb down and 1 lb up at 14-0-12, 77 lb down and 1 lb up at 16-0-12, 77 lb down and I Ito up at 18-0-12, 77 lb down and I lb up at 19-11-4, 77 lb down and 1 lb up at 21 -11 �4, 77 Ito down and 1 lb up at 23-11-4, 77 lb down and I lb up at 25-11-4, and 77 lb down and 1 lb up at 27-11-4, and 340 lb down and 223 lb up at 28-2-0 on bottom chord. The design/selection of such connection device(s) is the responsibility of others. 1 9) In the LOAD CASE(S) section, loads applied to the face of the truss are noted as front fl or back (B). LOAD CASE(S) Standard Walter P. Finn PE No.22839 MJTek USA, Inc. FL Cart 6634 6904 Parke East Blvd. Tampa Fl. 33610 Date: March 22,2018 WARNING - Verify design parameters and READ NOTES ON THIS AND tArcLvDED mTrEK REFERANCE PAGE M11-7473 rev. 10VU12015 BEFORE USE. Design valid for use only with MITek0 connectors. This design Is based only upon parameters shown,land is for an individual building component. not a truss system. Before use, the building designer must verify the applicabliffy of design parameters and properly Incorporate this design Into the overall building design. Bracing Indicated Is to prevent buckling of Individual truss web and/or chord mernbefs only. Additional temporary and permanent bracing WeW Is always required for stability and to prevent collcpse v4th possible personal Injury and property damage. for general guidance regarding the fabricallorr. storage, delivery, erection and bracing of trusses and truss systems. se.aANSI/JPI I Quaflt� Criteria, DSB-89 and BCSI Building Component 6904 Parke East Blvd. Safety Information available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 227,M 4. Tampa, FL 33610 M 11412 1 GRA I HIP CARLTON 299 T13569621 Chambers Truss, Inc., Fort Pierce, FL LOAD CASE(S) Standard 1) Dead + Roof Live (balanced): Lumber Increase=1.25, Plate Increase=1.25 Uniform Loads (plf) Vert: 1-3=-54, 3-7=-54, 7-9=-54,16-19=-20 Concentrated Loads (lb) Vert: 3�11 37(B) 5=-1 03(B) 7=-1 37(13) 14=-49(B) 15=-389(B) 1 0=-389(B) 1 31=-103(B) 33=-103(B) 34=-49(B) 35=-49(B) 36=-49(B) 37=-49(B) 38=-49 8.130 s Mar 112018 MITeK Industries, Inc. I hU Mar 22 09:08:02 2018 Page 2 ID:kFvnsnOwY419ZhO—nM3ic6ylJgg-zFVDA8Es6ifD9eO4xppirC5YMqocrRHuvin?QczYQmx :-I 03(B) 26=-1 03(B) 27=-1 03(B) 28=-1 03(B) 29=-1 03(B) I WARNING - Verify design parameters and READ NorEs ON THIS AND fricLuDED mrrEKREFERANCE PAGE Mll-7473 rev. 10103,2015 BEFORE USE. Design valid for use only with MITek0 connectors. This design Is based only upon, parameters shown, land Is for an Individual building component, not -- Wt a truss system. Before use, the building designer must verily the applicability of design parameters or , xi property Incorporate this design Into the overall building design. Bracing Indicated Is to prevent buckling of Individual truss web and/or chord members only. Additional temporary and permanent bracing MiTele is always required for stability and to prevent collapse with possible personal Injury and property damage. For general guidance regarding the fabrication. storage, delivery, erection and bracing of trusses and truss System% SeeANSI/TPI I Quallt� Criteria, DSB-89 and BCSI Building Component 6904 Parke East Blvd. Safety Information avallable from Truss Plate Institute, 218 N. Lee Street Suite 312, Alexandria, VA 22�1 4. Tampa, FL 33610 Job Tri M11412 �J2 C . Truss Type 10 MONO TRUSS -1-0-0 1-0-0 4.00 F1 T 2 3x4 = � Job Reference 8.130 s Mar 112018 MiTO 2-0-0 a 4 T113569622 22 09:08:02 2018 Paae 1 Scale = 1:7.8 LOADING (pst) SPACING- 2-0-0 CS1. DEFL. in (loc) I/defl Ud PLATES GRIP TCLL 20.0 Plate Grip DOL 1.25 TC 0.18 Vert(LL) -0.00 7 >999 360 MT20 244/190 TCDL 7.0 Lumber DOL 1.25 BC 0.07 Vert(CT) -0.00 7 >999 240 BCLL 0.0 Rep Stress Incr YES WB 0.00 Horz(CT) -0.00 3 n/a n/a BCDL 10.0 Code FBC2017/TP12014 Matrix -MP Wind(LL) 0.00 7 >999 240 Weight: 8 lb FT = 20% LUIMBER- BRACING- TOPCHORD 2x4 SP No.3 TOPCHORD Structural wood sheathing directly applied or 2-0-0 oc pudins. BOTCHORD 2x4 SP No.3 BOTCHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS. (lb/size) 3=37/Mechanical, 2=141/0-8-0, 4=22/Mechanical Max Harz 2=67(LC 12) Max Uplift 3=-27(LC 12), 2=-1 36(LC 12). 4=-3(LC 9) Max Grav 3=40(LC 17), 2=141 (LC 1), 4=31 (LC 3) FORCES. (lb) -Max. Comp./Max. Ten. -All forces 250 (lb) or less except when shown. NOTES- 1) Wind: ASCE 7-10; Vult=165mph (3-second gust) Vasd=128mph; TCDL=4.2psf; BIDDL=�5,.0psf; h=12ft; B=59ft; L=36ft; eave=5ft; Cat. 11; Exp C; Encl., GCpi=0.18; MWFRS (directional) and C-C Exterior(2) zone;C-C for members and forces& MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 2) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 3) * This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas Where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 4) Refer to girder(s) for truss to truss connections. 5) Provide mechanical connection (by others) of truss to bearing plate capable of withstandiL 27 lb uplift at joint 3, 136 lb uplift at joint 2 and 3 lb uplift at joint 4. Walter P. Finn PE No.22839 MiTek USA, Inc. FL Cort 6634 6904 Parke East Blvd. Tampa FL 33810 DaW March 22,2018 ,& WARNING - VerIfy d..Ign pammeters andRE4D NOTES ON THIS AND INCLUDED MITEKREFERANCE — ! -_ --- -_ '0103)2015 BEFORE USE. Design valid for usee only with MITek8 connectors. This design Is based only upon parameters �h., aAd Is for an individual building component, not a truss system. Before use. the building designer must verify the applicability of design parameters and properly Incorporate this design Into the overall building design. Bracing Indicated Is to prevent buckling of Individual truss web and/or chord members only. Additional temporary and permanent bracing MiTek' Is always required for stability and to prevent collapse with possible personal Injury and properly damage. For general guidance regarding the fabricallort stofage. delivery, erection and bracing of trusses and truss system% seeANSI/TPI I Quality Criteria, DSB-89 and BCSI Building Component 6904 Parke East Blvd. Safety Information available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria. VA 22,314. Tampa, FL 33610 Job Truss Truss Type I aty Ply M11412 J4 MONO TRUSS 8 1 � CARLTON 299 T13569623 Job Refe nce (optional) Chambers Truss, Inc., Fort Pierce, FL 8.130 s Mar 112018 MiTek Industries, Inc. Thu Mar 22 09:08:03 2018 Page I ID:kFvnsnowY419ZhC�-nM3lc6ylJgg-RR3cOUEUt?n4mozGVWKxOPdpOEEya5bl8MWYy3zYQmw 4-0-0 __11__00_00 4-0-0 Scale 1: 11.1 3 4.00 fT2_ 8 t2 2 W = 4 LOADING (psf) SPACING- 2-0-0 CS11. DEFL. in (loc) I/defl L/d PLATES GRIP TCLL 20.0 Plate Grip DOL 1.25 TC 0.37 Vert(LL) -0.01 4-7 >999 360 MT20 244/190 TCDL 7.0 Lumber DOL 1.25 BC 0.37 Vert(CT) -0.02 4-7 >999 240 BCLL 0.0 Rep Stress Incr YES WB 0.00 Horz(CT) -0.00 3 n/a. n/a BCDL 10.0 Code FBC2017ITP12014 Matrix -MP WInd(LQ 0.02 4-7 >999 240 Weight: 14 lb FT = 20% LIUMBER- BRACING - TOP CHORD 2x4 SP No.3 TOPCHORD Structural wood sheathing directly applied or 4-0-0 oc pudins. BOTCHORD 2x4 SP No.3 BOTCHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS. (lb/size) 3=87/Mechanical, 2=204/0-8-0, 4=49/Mechanical Max Harz 2=102(LC 12) Max Uplift 3=-77(LC 12), 2=-159(LC 12), 4=-7(LC 12) Max Grav 3=91 (LC 17), 2=204(LC 1), 4=67(LC 3) FORCES. (lb) -Max. Comp./Max. Ten. -All forces 250 (lb) or less except when shown. NOTES- 1) Wind: ASCE 7-10; Vult=165mph (3-second gust) Vasd=128mph; TCDL.=4.2psf; 13CIDI-1.0ps1f; h=12ft; B=59ft; L=36ft; eave=5ft; Cat. 11; Exp C; Encl., GCpl=0.18; MWFRS (directional) and C-C Exterlor(2) -1-0-0 to 2-7-3, 19 1 terior(l) 2-7-3 to 3-10-4 zone;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL 1.60 2) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 3) * This truss has been designed for a live load of 20.Opsf on the bottom chord In all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 4) Refer to girder(s) for truss to truss connections. 5) Provide mechanical connection (by others) of truss to bearing plate cap —le or WILI I�Lal rding 77 lb uplift at joint 3, 159 lb uplift at joint 2 and 7 lb uplift at joint 4. Walter P. Finn PE No.22839 MiTek USA, Inc. Fl. Cert 6834 6904 Parke East Blvd. Tampa Fl. 33610 Date: March 22,2018 WARNING- Verify desfgn parameter. and READ NOTES ON THIS AND INCLUDED MMEKREFERANCE I PAGE M11.7473 rev. 1010312015 BEFORE USE. Design valid for use only with MITek(0) connectors. This design Is based only upon parameters shown,l and Is for an Individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and property Incorporate this design Into the overall building design. Bracing Indicated Is to prevent buckling of individual truss web and/or chord merribers only. Additional temporary and permanent bracing MiTeW Is always required for stability and to prevent collapse with possible personal Injury and property d&nage. For general guidance regarding the fabrication. storage, delivery, erection and bracing of trusses and truSS sYsloM s00ANSl/TPIl Qualll� Criteria, DSB-89 and BCSI Building Component 6904 Parke East Blvd. Safety Informalton available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22�1 4. Tampa, FIL 33610 1 T13569624 M11412 Truss, Inc., Fort 2 MONO TRUSS 4.00112 18 1 1 1 Job Reference (optional) 8.130 s Mar 11 2018 MiTek Industries, Inc. Thu Mar 22 09:08:04 2018 Page I ID:kFvnsnOwY419ZhO—nM3lc6ylJgg-wec—bqF6eJvxOyYS3DrAwdA_VeSsJYrBMOG6UVzyQmv 6-0-0 P-n-n i 3 Scale = 1:14.3 3x4 4 6-0-0 6-0-0 LOADING (psf) SPACING- 2-0-0 CS1. DEFL. in (ioc) I/defl Ud PLATES GRIP TCLL 20.0 Plate Grip DOL 1.25 TC 0.35 Vert(LL) -0.05 4-7 >999 360 MT20 244/190 TCDL 7.0 Lumber DOL 1.25 BC 0.83 Vert(CT) -0.11 4-7 >652 240 BCLL 0.0 Rep Stress Incr YES WB 0.00 Horz(CT) -0.00 3 rVa n/a BCDL 10.0 Code FBC2017fTP12014 Matrix -MP Wind(LL) 0.11 4-7 >639 240 Weight: 20 lb FT = 20% LUMBER- BRACING - TOP CHORD 2x4 SP M 30 TOPCHORD Structural wood sheathing directly applied or 6-0-0 oc pudins. BOTCHORD 2x4 SP No.3 BOTCHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS. (lb/size) 3=142/Mechanical,2=275/0-8-0,4=70/MechanicaI Max Harz 2=140(LC 12) Max Uplift 3=-129(LC 12), 2=-192(LC 12), 4=-8(LC 12) Max Grav 3=148(LC 17), 2=276(LC 1), 4=1 00(1-C 3) FORCES. (lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. NOTES- 1) Wind: ASCE 7-10; Vuft=165mph (3-second gust) Vasd=128mph; TCDL=4.2psf; BCDL--3.Opsf; h=12ft; B=59ft; L=36ft; eave=5ft; Cat. 11; Exp C; Encl., GCpi=0.18; MWFRS (directional) and C-C Exterior(2) -1-0-0 to 2-7-3, Interior(l) 2-7-3 to 5-10-4 zone;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 2) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 3) * This truss has been designed for a live load of 20.Opsf on the bottom chord in all aress where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 4) Refer to girder(s) for truss to truss connections. 5) Provide mechanical connection (by others) of truss to bearing plate capable or withstanding 129 lb uplift at joint 3, 192 lb uplift at joint 2 and 8 lb uplift at joint 4. 1 Wafter P. Finn PE No.22839 MiTek USA, Inc. Fl. Cart 6634 0904 Parke East Blvd. Tampa Fl. 33610 Date: March 22,2018 ,& WARNING- Verify design parameters and READ NOTES Off THIS AND INCLUDED MITEK REFE—Y, E PAGEM11-7473 rev. 10103)2016 BEFORE USE. Design valid for use only \vIth MITek8 connectors. This design Is based only upon parameters sho\4n, and Is for an Individual building component, not Wit a truss system. Before use, the building designer must vedfy the applicability of design parameters and properly Incorporate this design Into the overall building design. Bracing Indicated Is to prevent buckling of Individual truss web and/or chord mdmbers only, Addillonal temporary and permanent bracing MiTek* Is always required for stability and to prevent collapse wUh possible personal Injury and properly damage. For general guidance regarding the labricatiom storage, delivery, erection and bracing of trusses and truss systems. seeANSIfTPI 1 Quallty Criteria, DSB-89 cmd Best Building Component 6904 Parke East Blvd. Safety Informatilon available from Inuss Plate Institute, 218 N. Lee Street, Suite 312. Alexandria, VA 22314. 1 Tampa, FL 33610 lJob Truss Truss Type cry Ply CARLTON 29 T13569625 M11412 J8 MONO TRUSS 11 1 Job Reference (optional) Chambers Truss, Inc., Fort Pierce, FIL W �� Plate 4.00 8.130 s mar 11 2018 miTek industries, inc. Thu Mar 22 09:08:04 201i 6 Page i ID:kFvnsnOwY4lgZhO—nM3lc6ylJgg-wec�-bqF6eJvxOyYS3DrAwdAwSeYYJYrBMOG6UVzyQmv 8-0-0 8-0-0 LOADING (pst) SPACING- 2-0-0 cSI. DEFL. in (loc) I/defl L/d TCLL 20.0 Plate Grip DOL 1.25 TC 0.61 Vert(LL) -0.14 4-7 >676 360 TCDI_ Lumber DOL 1.25 BC 0.47 Vert(CT) -0�30 4-7 >31 0 240 BCLL 0�0. Rep Stress Incr YES WB 0.00 Horz(CT) -0.00 3 n1a n/a BCDL 10.0 Code FBC2017ITP12014 Matdx-MP WInd(LL) 0.26 4-7 >368 240 LIUMBER- TOP CHORD 2X4 SP M 30 BOT CHORD 2X4 SP M 30 REACTIONS. (lb/size) 3=188/Mechanical,2=348/0-8-0,4=99/MechanicaI Max Horz 2=178(LO 12) Max Uplift 3=-1 74(LC 12), 2=-226(LC 12), 4=-1 3(LC 12) Max Grav 3=1 95(LC 17), 2=348(LC 1), 4=1 41 (LC 3) FORCES. (lb) -Max. Comp./Max. Ten. -All forces 250 (lb) or less except when shown. Scale = 1: 17.7 PLATES GRIP MT20 244/190 Weight: 26 lb FT = 20% BRACING- TOPCHORD Structural wood sheathing directly applied or 6-0-0 oc purlins. BOTCHORD Rigid ceiling directly applied or 10-0-0 oc bracing. NOTES- I 1) Wind: ASCE 7-10; Vult=165mph (3-second gust) Vasd=128mph; TCDL=4.2psf; BCDL=3.Opsf; h=12ft; B=59ft; L=36ft; eave=5ft; Cat. 11; Exp C; Encl., GCpi=0.18; MWFRS (directional) and C-C Extehor(2) -1-0-0 to 2-7-3, Interior(l) 2-7-3 to 7-10-4 zone;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL-il 160 2) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 3) * This truss has been designed for a live load of 20.Opsf on the bottom chord In all areas here a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 4) Refer to girder(s) for truss to truss connections. 5) Provide mechanical connection (by others) of truss to bearing plate capable of vvlthstandi�g 174 lb uplift at joint 3, 226 lb uplift at joint 2 and 13 lb uplift at joint 4. Walter P. Finn PE No.22839 MiTek USA, Inc. FL Cert 6634 6904 Parke East Blvd. Tampa FL 33610 Date: March 22,2018 ,& WARNING- Verify design Parameter. and READ NOTES Off THIS AND INCLUDED MITEKREFERANCE PAGE Mll-7473 rev. 1010312015 BEFORE USE, Design valid foruse onlywith MITek8 connectors. ThIsclesign Is based onlyupon parameters shown, and Isfor an Individual building component. not a truss system. Before use, the building designer must verify the applicability of design parameters and properly Incorporate this design Into the overall building design. Bracing Indicated Is to prevent buckling of Individual truss web and/or chord members only. Additional temporary and permanent bracing MiTek* Is always required for stability and to prevent collapse with possIbfe personal Injury and property domage. For general guidance regarding the fabri,collon, storage. dellvery� erection and bracing of trusses and truss syslems� seeANSI/TPI I Quality Criteria, DSB-89 and BCSI Building Component 6904 Parke East Blvd. Safety Information avdiable from Truss Plate Institute. 218 N. Lee Street Suite 312, Mexandrla,VA,2231�. Tampa, FIL 33610 'Ab Truss Truss Type Qty Ply CARLTON 299 T13569626 JA8 MONO TRUSS 11 Job Referei Chambers Truss, Inc., Fort Pierce, FL 8.130 s Mar 112018 MiTek Industries, Inc. Thu Mar 22 09:08:05 2018 Page I ID:kFvnsnOwY4l9ZhO—nM3lc6ylJgg-OqAMoAGkPdloO66fdxMPTqi5hlu62?5Kbg?fIXZYQmu -1-0-0 7-10-0 1-0-0 7-10-0 Scale 1:17.6 3 4.00 F1 8. 2 3x4 4 7-10-0 7-10-0 Plate Offsets (X,Y)-- [2:0-1-14,Edgel LOADING (psf) SPACING- 2-0-0 CS1. DEFL. in (loc) I/defl L/d PLATES GRIP TCLL 20.0 Plate Grip DOIL 1.25 TC 0.58 Vert(LL) -0.13 4-7 >721 360 MT20 244/190 TCIDL 7.0 Lumber DOL 1.25 BC 0.45 Vert(CT) -0.28 4-7 >331 240 BCLL 0.0 Rep Stress Incr YES WB 0.00 Horz(CT) -0.00 3 n/a n/a BCDL 10.0 Code FBC2017/-FP]2014 Matrix -MP Wind(LL) 0.24 4-7 >392 240 Weight: 26 lb FT = 20% LUMBER- BRACING- TOPCHORD 2x4 SP M 30 TOPCHORD Structural wood sheathing directly applied or 6-0-0 oc puffins. BOTCHORD 2x4 SP M 30 BOTCHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS. (lb/size) 3=184/MeChanical,2=342/0-8-0,4=97/MechanicaI Max Horz 2= 1 75(LC 12) Max Uplift 3=-1 70(LC 12), 2=-223(LC 12), 4=-1 3(LC 12) Max Grav 3=191(LC 17), 2=342(LC 1), 4=138(LC 3) FORCES. (lb) -Max. Comp./Max. Ten. -All forces 250 (lb) or less except when shown. NOTES- 1) Wind: ASCE 7-10; Vult=165mph (3-second gust) Vasd=128mph; TCDL=4.2psf; BCDL=:3.Opsf; h=12ft; B=59ft; L=36ft; eave=5ft; Cat. 11; Exp C; Encl., GCpi=0.18; MWFRS (directional) and C-C Exterior(2) -1-0-0 to 2-7-3, Interior(l) 2-7-3 to 7-8-4 zone;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 2) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 3) * This truss has been designed for a live load of 20.Opsf on the bottom chord in all area's where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 4) Refer to girder(s) for truss to truss connections. 5) Provide mechanical connection (by others) of truss to bearing plate capable of withstand' 170 lb uplift at joint 3, 223 fb uplift at joint 2 and 13 lb uplift at joint 4. Walter P. Finn PE No.22839 MlTek USA, Inc. Fl. Cert 6634 69D4 Parke East Blvd. Tampa FL 33610 Date: March 22,201 WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED M17EK REFERANCE PAGE Mll-7473 rev. 1010312015 BEFORE USE. Design valid for use only vAth Mffek(D connectors. This design Is based only upon Parameters sho". and Is for on Individual building component. not a truss system. Before use, the building designer must verify the applicability ofdesign parameters �nd property incorporate this design Into the overall building design. Bracing Indicated Is to prevent buckling of Individual truss web and/or chord me mbers only. Additional temporary and permanent bracing MOW Is always required for stab4lity and to prevent collapse vvith possible personal Injury and property damage. For general guidance regarding the fabrication, storage. delivery, erection and bracing of trusses and truss systems. seeANSI/TPI I Quality Criferla, DSB-89 and BCSI Building Component 6904 Parke East Blvd. Safety Information avallable from Truss Plate Institute. 218 N. Lee Street —quite 312, Mexandria, VA 22314. 1 Taffq)a, FL 33610 Job Truss Truss Type oty Ply CARLTON 299 T13569627 M11412 KJB MONO TRUSS 2 1 Job Reference (optional) Chambers Truss, Inc., Fort Pierce, FL 8.130 s Mar 112018 MiTek Industries, Inc. Thu Mar 22 09:08:06 2018 Page 1 ID:kFvnsnOwY4lgZhO—nM3lc6ylJ9g-sOkkOWHNAwgfdFhrAeteO2FMER]UnNxUqJICZNzYomt -1`0 7-2-7 11-3-0 7-2-7 4-0-9 Scale4: 1: 2.83 72— 3x4 1.2. 3 11 10 2 13 14 6 15 2x3 3x4 5 7-2-7 11-0-12 W31 0 7-2-7 3-10-5 4 LOADING (psf) SPACING- 2-0-0 CSI. DEFL. in (loc) I/defl Ud PLATES GRIP TCLL 20.0 Plate Grip DOL 1.25 TC 0.21 Vert(LL) -0.05 6-9 >999 360 MT20 244/190 TCDL 7.0 Lumber DOL 1.25 BC 0.25 Vert(CT) -0.10 6-9 >999 240 BCLL 0.0 Rep Stress Incr NO WB 0.35 Horz(CT) 0.01 5 n/a n/a BCDL 10.0 Code FBC2017/TP]2014 Matrix -MS Wind(LL) -0.04 6-9 >999 240 Weight: 44 lb FT = 20% LUIMEIER- TOP CHORD 2X4 SP M 30 BOT CHORD 2X4 SP M 30 WEBS 2x4 SP No.3 REACTIONS. (lb/size) 4=90/Mechanical, 2=462/0-11-5,5=406/Mechanical Max Horz 2=1 78(LC 8) Max Uplift 4=-1 02(LC 8), 2=-1 87(LC 8), 5=-1 1 8(LC 8) FORCES. (b) -Max. Comp./Max. Ten. -All forces 250 (lb) or less except when shown. TOPCHORD 2-3=-866/230 BOTCHORD 2-6=-2341833, 5-6=-234/833 WEBS 3-6=0/287, 3-5=-g 13/257 NOTES- 1) Wind; ASCE 7-10; Vult=165mph (3-second gust) Vasd=128mph; TCDL=4.2psf; BCDL- 11; Exp C; Encl., GCpi=O.l 8; MWFRS (directional); Lumber DOL=1.60 plate grip DOL=1 2) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with ; 3) * This truss has been designed for a live load of 20.Opsf on the bottom chord in all area will fit between the bottom chord and any other members. 4) Refer to girder(s) for truss to truss connections. 5) Provide mechanical connection (by others) of truss to bearing plate capable of withstan joint 2 and 118 lb uplift at joint 5. 6) Hanger(s) or other connection device(s) shall be provided sufficient to support concentr 2-11-0, 39 lb down and 58 ib up at 2-11-0, 8 lb down and 101 lb up at 5-8-15, 8 lb do'A and 143 lb up at 8-6-14, and 42 lb down and 143 lb up at 8-6-14 on top chord, and 47 and 28 Ito up at 2-11-0, 47 lb down at 5-8-15, 47 lb down at 5-8-15, and 31 lb down ar lb up at B-6-14 on bottom chord. The design/selection of such connection device(s) is 7) In the LOAD CASE(S) section, loads applied to the face of the truss are noted as front BRACING- TOPCHORD Structural wood sheathing directly applied or 6-0-0 oc purins. BOTCHORD Rigid ceiling directly applied or 10-0-0 oc bracing. h=12ft; B=59ft; L=36ft; eave=5ft; Cat. iy other live loads. where a rectangle 3-6-0 tall by 2-0-0 wide 102 lb uplift at joint 4, 187 lb uplift at ed load(s) 39 lb down and 58 lb up at and 101 lb up at 5-8-15, and 42 lb down down and 28 lb up at 2-11-0, 47 lb down 14 lb up at 8-6-14, and 31 lb down and 14 e responsibility of others. ) or back (B). LOAD CASE(S) Standard 1) Dead + Roof Live (balanced): Lumber lnerease=1.25, Plate Increase:=1.25 Uniform Loads (plf) Vert: 1-4=-54, 5-7=-20 Concentrated Loads (lb) Vert: 1 0=80(F=40, B=40) 11 =-2(F=-1, B=-1) 12=-83(F=-42, 13=42) 13=1 4(F=711 B=7) 14=-20(F=-1 0, B=-1 0) 1 5=-50(F=-25, 13�25) Walter P. Finn PE No.22839 M!Tek USA, Inc. Fl. Cert 6834 6904 Parke East Blvd. Tampa Fl. 33610 Date: March 22,2018 ,& WARNING- Verity design parameters and RE4DNOTES ON THIS AND INCLUDED MffEKREFERANCEI PAGE M11-7473 rev. 1010312015 BEFORE USE. Design valid for use only with M]Tek(b connectors. This design Is based only upor) parameters show4 and Is for an Individual building component, not Sol' a truss system. Before use. the building designer must verify the applicability of design parameters building design. Bracing Indicated Is to prevent buckling of individual truss web and/or chord me6ibefs bnd properly incorporate this design Into the overall only. Additional temporary and permanent bracing Mel( is always required for stability and to prevent collapse with possible personal Injury and property d6mago. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss system% seeANSI/TPI I Quality Criteria, DSB-89 and BCSI Building Component Safety Information avallable from TFUSS Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314. 6904 Parke East Blvd. Tampa, FL 33610 �Job Truss Truss Type Qty Ply CARLTON 299 T13569628 KJA8 MONO TRUSS 2 1 1 Job Reference (optional) Chambers Truss, Inc., Fort Pierce, FL 8.130 s Mar 112018 MiTek Industries, Inc. Thu Mar 22 09:08:06 2018 Page 1 0 ID:kFvnsnOwY4l9ZhO�-nM3lc6yiJgg-sOkkOWHNAwgfdFhrAeteO2FMMRinnN6UqJICZNzYQmt -1 _5_0 6-10-0 11-0-3 1-5-0 6-10-0 1 4-2-3 3X4 = LOADING (psf) TCLL 20.0 TCDL 7.0 BCLI_ 0.0 BCDL 10.0 LUMBER - TOP CHORD 2X4 SP M 30 BOT CHORD 2X4 SP M 30 WEBS 2x4 SP No.3 SPACING- 2-0-0 Plate Grip DOL 1.25 Lumber DOL 1.25 Rep Stress Incr NO Code FBC2017/TP12014 2.8311,2 3X4 ::: If 10 13 14 6 2X3 11 6-10-0 cSI. TC 0.20 BC 0.23 WB 0.34 Mattix-MS REACTIONS. (lb/size) 4=106/Mechanical,2=447/0-11-5,5=385/MechanicaI Max Horz 2=175(LC 8) Max Uplift 4=-1 07(LC 8), 2=-321 (LC 8), 5=-202(LC 5) FORCES. (lb) -Max. Comp./Max. Ten. -All forces 250 (lb) or less except when shown. TOPCHORD 2-3=-846/526 BOTCHORD 2-6=-520/815, 5-6=-520/815 WEBS 3-6=0/268, 3-5=-8841665 12 15 11-0-3 Scale = 1:19.9 3X4 = DEFIL. in (loc) I/defl Ud PLATES GRIP Vert(LL) 0.06 6-9 >999 240 MT20 244/190 Vert(CT) -0.08 6-9 >999 240 Horz(CT) 0.01 5 n1a n/a Weight: 43 lb FT = 20% BRACING - TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins BOTCHORD Rigid ceiling directly applied or 10-0-0 oc bracing. NOTES- 1) Wind: ASCE 7-10; Vult=1 65mph (3-second gust) Vasd=1 28mph; TCDL=4.2psf; BCDL=3.1opsf; h=1 2ft; B=59ft; L=36ft; eave=5ft; Cat. 11; Exp, C; Encl., GCpi=0.18; MWFRS (directional); Lumber DOL=1.60 plate grip DOL=1.60 2) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 3) * This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas khere a rectangle 3-6-0 tall by 2-0-0 wide Mj I fit between the bottom chord and any other members. 4) Refer to girder(s) for truss to truss connections. 1 5) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 107 lb uplift at joint 4, 321 lb uplift at joint 2 and 202 lb uplift at joint 5. 6) Hanger(s) or other connection device(s) shall be provided sufficient to support concentrat.1 d load(s) 39 lb down and 58 lb up at 2-11-0, 39 lb down and 58 lb up at 2-11 -0, B lb down and 101 lb up at 5-8-15, 8 lb down and 101 lb up at 5-8-15, and 42 lb down and 143 lb up at 8-6-14, and 42 lb down and 143 lb up at B-6-14 on top chord, and 31 lb Op at 2-11-0, 31 lb up at 2-11 -0, 10 lb down and 30 lb up at 5-8-15, 10 lb down and 30 lb up at 5-8-15, and 31 lb down and 14 lb up at 8-6-14, and 31 lb down and 14 lb up at 8-6-14 on bottom chord. The desigri/selection of such connection device(s) is the responsibility of others. 7) In the LOAD CASE(S) section, loads applied to the face of the truss are noted as front (F) or back (B). LOAD CASE(S) Standard I 1) Dead + Roof Live (balanced): Lumber Increase=1.25, Plate Increase=1.25 Uniform Loads (plf) Vert: 1-4=-54, 5-7=-20 Concentrated Loads (lb) Vert: 1 0=80(F=40, B--40) 1 1=-2(F=-1, B=-1) 12=-83(F=-42, B=-42) 13=14(F=7, B=7) 14=-20(F=-10, B=-10) 15=-50(F=-25, B�25) I Walter P. Finn PE No.22839 MITek USA, Inc. FL Cert 6634 6904 Parke East Blvd. Tampa FL 33610 Date: March 22,2018 WARNING- Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEKREFERANCE PAGEM[I-7473 rev. la(MV2015 BEFORE USE. Design valid for use only with MITek@ connectors. This design Is based only upon parameters shown, or',id is for an Individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly Incorporate this design Into the overall building design. Bracing Indicated Is to prevent buckling of Individual truss web and/or chord memb6rs only. Additional temporary and permanent bracing M!Tek* Is always required for stability and to prevent collapse with possible personal Injury and property dama ge. For general guidance regarding the . labricallorr, storage, delivery, erection and bracing of trusses and truss systems, seeANSI/TPI I Quality Criteria, DSB-89 and BCSI Building Component 6904 Parke East Blvd. Safety Information available from Truss Plate Institute, 218 N. Lee Street Suite 312, Plexandria. VA 22,11 Tampa, Fl. 33610 Symbols � Numbering system � A General Safety Notes PLATE LOCATION AND ORIENTATION 3/�' Center plate on joint unless x, y offsets are indicated, Dimensions are in ff-in-sixteenths. Apply plates to both sides of truss and fully embed teeth. 0-111g. -7t- For 4 x 2 orientation, locate plates 0-1/i�' from outside edge of truss. This symbol indicates the required direction of slots in connector plates, *Plate location details available in MiTek 20/20 software or upon request. PLATE SIZE The first dimension is the plate 4 x 4 width measured perpendicular to slots. Second dimension is the length parallel to slots. LATERAL BRACING LOCATION Indicated by symbol shown and/or by text in the bracing section of the output. Use T or I bracing if indicated. Indicates location where bearings (supports) occur. Icons vary but reaction section indicates joint number where bearings occur. Min size shown is for crushing only. Industry Standards: ANSI/TP11: National Design Specification for Metal Plate Connected Wood Truss Construction. DSB-89: Design Standard for Bracing. BCSI: Building Component Safety Information, Guide to Good Practice for Handling, Installing & Bracing of Metal Plate Connected Wood Trusses, q a 0 '7 0 0- 0 6-4-8 1 dimensions shown in ft-in-sixteenths I(Drawings not to scale) 2 TOP CHORDS 8 7 6 5 JOINTS ARE GENERALLY NUMBERED/LETTERED CLOCKWISE AROUND THE TRUSS STARTING AT THE JOINT FARTHEST TO THE LEFT. CHORDS AND WEBS ARE IDENTIFIED BY END JOINT NUMBERS/LETTERS. PRODUCT CODE APPROVALS ICC-ES Reaoqs� ESR- 1311, ESR- 1352, ESR 1988 ER-3907, ESR-2362, ESR-1397, ESR-3282 0 0 Trusses are designed for wind loads in the plane of the truss unless otherwise shown. Lumber design values are in accordance with ANSI/TP1 1 section 6.3 These truss designs rely on lumber values established by others. @ 2012 MiTek@ All Rights Reserved MITek Engineering Reference Sheet: Mll-7473 rev. 10/03/2015 Failure to Follow Could Cause Property Damage or Personal Injury 1 . Additional stability bracing for truss system, e.g. diagonal or X-bracing, is always required. See BCSI. 2. Truss bracing must be designed by an engineer. For wide truss spacing, individual lateral braces themselves may require bracing, or alternative Tor I bracing should be considered. 3. Never exceed the design loading shown and never stack materials on inadequately braced trusses. 4. Provide copies of this truss design to the building designer, erection supervisor, property owner and all other interested parties. 5. Cut members to bear tightly against each other. 6. Place plates on each face of truss at each joint and embed fully. Knots and wane ationt locations are regulated by ANS1/TPl 1. 7. Design assumes trusses will be suitably protected from the environment in accord with ANSI/TPI 1. 8. Unless otherwise noted, moisture content of lumber Shall not exceed 19% at time of fabrication. 9. Unless expressly noted, this design is not applicable for use with fire retardant, preservative treated, or green lumber. 10. ca—m6e Fis anon-s�wct dral C onsid—eratlon and —is the responsibility of truss fabricator, General practice is to comber for dead load deflection. 11. Plate type, size, orientation and location dimensions indicated ore minimum plating requirements. 12. Lumber used shall be of the species and size, and in all respects, equal to or better than that specified. 13. Top chords must be sheathed or purlins provided at spacing indicated on design. 14. Bottom chords require lateral bracing at 10 ft. spacing, or less, if no ceiling is installed, unless otherwise noted. 15. Connections not shown are the responsibility of others. 16. Do not cut or alter truss member or plate without prior approval of an engineer. 17. Install and load vertically unless Indicated otherwise. 18. Use of green or treated lumber may pose unacceptable environmental, health or performance risks. Consult with project engineer before use. 19. Review all portions of this design (front back, words and pictures) before use. Reviewing pictures alone is not sufficient. 20. Design assumes manufacture in accordance with ANSI/TPI 1 Quality Criteria,