Loading...
HomeMy WebLinkAboutENERGY EFFICIENCY CODEFORMf'R405-2017 FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION Florida Department of Business and Professional Regulation - Residential Performance Method I Project Name: WYNNE THE WINDSOR IMPACT Builder Name: WYNNE DEVELOPMENT Street: THE WINDSOR Permit Office: ST. LUCIE COUNTY qity, State, Zip: FT. PIERCE, FL, Owner: Permit Number: Jurisdiction: Design Location: FL, Fort Pierce County:: St. Lucie (Florida Climate Zone 2 1. New construction or existing New (From Plans) 9. Wall Types (1432.0 sqft.) Insulation Area 2. Single family or multiple family Single-family a. Concrete Block - Ext Insul, Exterior R=4.1 1224.00 fl:2 b. Frame - Wood, Adjacent R=l 1.0 208.00 ft' 3. Number of units, if multiple family 1 c. N/A R= ft2 4. Number of Bedrooms 3 d. N/A R= ft2 10. Ceiling Types (1753.0 sqft.) Insulation Area 5. Is this a worst case? Yes a. Under Attic (Vented) R=30.0 1753.00 fl:2 6. Conditioned floor area above grade (fl:2) 1753 b. N/A R= ft2 Conditioned floor area below grade (fl:2) 0 c. N/A R= ft2 11. Ducts R fl:2 7. Windows(151.4 sqft.) Description Area! a. Sup: Attic, Ret: Attic, AH: Attic 6 225 a. U-Factor: Sgl, U=0.63 Ill . 36 ft- SHGC: SHGC=0.25 b. U-Factor: Sgl, U=0.65 40.0� ft2 12. Cooling systems kBtu/hr Efficiency SHGC: SHGC=0.21 a. Central Unit 34.8 SEER:15.00 c. U-Factor: N/A ft2 SHGC: 110 13. Heating systems kBtu/hr Efficiency d. U-Factor: N/A ft2 a. Electric Heat Pump 34.8 HSPF:8.50 SHGC: Area Weighted Average Overhang Depth: 2.8 ft. Area Weighted Average SHGC: 0.236 14. Hot water systems I a. Electric Cap: 40 gallons 8. FloorTypes (1753.0 sqft.) Insulation Ai EF: 0.970 a. Slab -On -Grade Edge Insulation R=0.0 1753 - fl:2 b. Conservation features b. N/A R= ft2 None c. N/A R= ft2 15. Credits Pstat Glass/Floor Area: 0.086 Total Prop I sed Modi led Loads: 53.83 PASS Total Baseline Loads: 53.85 1 1 hereby certify that the plans and specifications co e Ld by V Zy Review of the plans and E S this calculation are in compliance with the Florida En specifications covered by this z *t� Code. calculation indicates compliance with the Florida Energy Code. vs PREPM BY' '!4 �2� >�:K_ 1../ DATE. Af le AK�V Before construction is COMPleted this building will be inspected for compliance with Section 553.908 I hereby certify that this building, as de ,signed, the Florida Energ Code is in c ompliance Florida Statutes. with WME OWNERI���. BUILDING OFFICIAL: DATE: VQ5 DATE: - I - Compliance requires certification by the air certified factory -sealed in accordance with I - Compliance requires an Air Barrier and Insu envelope leakage test report with envelope le unit manufacturer that the air handier enclosure qualifies as .1. Inspection Checklist in accordance with R402.4.1.1 and this project requires an no greater than 7.00 ACH50 (R402.4.1.2). 4/16/2018 8:46 PM EnergyGauge@JUSA - FlaRes2017 Section R405.4.1 Compliant Software Page 1 of 5 FORM R405-2017 PROJECT Title: WYNNE THE WINDSOR IM Bedrooms: 3 Address Type: Street Address Building Type: User Conditi loned Area: 1753 Lot # Owner Name: I Total Stories: 1 Block/Subdivision: #of Units: 1 Worst I Case: Yes PlatBook: Builder Name: WYNNE DEVELOPMENT Rotate Angle: 225 Street: THE WINDSOR Permit Office: ST. LUCIE COUNTY Cross entilation: No County: St. Lucie Jurisdiction: Whole House Fan: No City, State, Zip: FT. PIERCE, Family Type: Single-family FL, New/Existing: New (From Plans) Comment: CLIMATE V Design Temp Int Design Temp Heating Design Daily Temp Design Location TMY Site 97.5% 2.5% Winter Summer Degree Days Moisture Range FL, Fort Pierce FL—VERO—BEACH—MUNI 39 90 70 75 299 62 Low I BLOCKS Number Name Area Volume I 1 Entire House 1753 14024 SPACES Number Name Area Volume Kitchen Occupants Bedrooms Infil ID Finished Cooled Heated 1 MASTER BEDROO 224 1792 No 0 1 1 Yes Yes Yes 2 WIC 63 504 No 0 1 No Yes Yes 3 MASTER BATH 56 448 No 0 1 Yes Yes Yes 4 M. BATH 61 488 No 0 1 Yes Yes Yes 5 LAUDRY 36 288 No 0 1 No Yes Yes 6 BEDROOM 2 180 144 1 No 0 1 1 Yes Yes Yes 7 DINING/GREAT R 588 470 No 2 1 Yes Yes Yes 8 KITCHEN 209 1672 Yes 0 1 Yes Yes Yes 9 BATH 50 400 No 0 1 Yes Yes Yes 10 HALL 25 200 No 0 1 No Yes Yes 11 FOYER 92 736 No 0 1 Yes Yes Yes 12 BEDROOM 3 169 135, No 0 1 1 Yes Yes Yes FLOORS y# Floor Type Space Perimeter Perimeter R-Value Area Joist R-Value Tile Wood Carpet 1 Slab -On -Grade Edge Insulatio MASTER BEbRO 37 ft 0 224 ft2 ---- 0 1 0 2 Slab -On -Grade Edge Insulatio WIC 1 ft 0 63 ft2 ---- 0 1 0 3 Slab -On -Grade Edge Insulatio MASTER BATH 8 ft 0 56 ft2 ---- 0 1 0 4 Slab -On -Grade Edge Insulatio M. BAT� 7 ft 0 61 ft2 ---- 0 1 0 5 Slab -On -Grade Edge Insulatio LAUDR�, 1 ft 0 1 36 ft2 ---- 0 1 0 4/16/2018 8:46 PM EnergyGauge@ USA - FlaRes2017 Section R405,4,1 Compliant Software Page 2 of 5 FORM R405-2017 FLOORS v# Floor Type Space Perimeter Perimeter R-Value Area Joist R-Value Tile Wood Carpet 6 Slab -On -Grade Edge Insulatio BEDROOM 2 12 ft 0 180 ft2 ---- 0 1 0 7 Slab -On -Grade Edge Insulatio DINING/GREAT 50ft 0 588 ft2 ---- 0 1 0 8 Slab -On -Grade Edge Insulatio KITCHEN 11 ft 0 209 ft2 ---- 0 1 0 9 Slab -On -Grade Edge Insulatio BATH 5 ft 0 50 ft2 ---- 0 1 0 10SIab-On-Grade Edge Insulatio HALL 1 ft 0 25 ft2 ---- 0 1 0 1 1SIab-On-Grade Edge Insulatio FOYER 9 ft 0 92 ft2 ---- 0 1 0 12SIab-On-Grade Edge Insulatio BEDROOM 3 14 ft 0 169 lit' ---- 0 1 0 ROOF Roof Gable Roof Solar SA Emitt Emitt Deck Pitch # Type Materials Area Area Color Absor. Tested Tested Insul. (deg) 1 Gable or Shed Metal 1847 ft2 292 fl:2 Light 0.6 No 0.9 No 0 18.4 ATTIC V# Type Ventilation Vent Ratio (1 in) Area RBS IRCC 1 Full attic Vented 150 1753 ft2 N N CEILING V# Ceiling Type S 'Pace R-Value Ins Type Area Framing Frac Truss Type 1 Under Attic (Vented) MAS7, BEDRO 30 Blown 224 ft2 0.1 Wood 2 Under Attic (Vented) C 30 Blown 63 ft2 0.1 Wood 3 Under Attic (Vented) rMASTER BATH 30 Blown 56 ft2 0.1 Wood 4 Under Attic (Vented) M -1 BATH 30 Blown 61 ft2 0.1 Wood 5 Under Attic (Vented) LAUDRY 30 Blown 36 ft2 0.1 Wood 6 Under Attic (Vented) BED ROOM 2 30 Blown 180 ft2 0.1 Wood I 7 Under Attic (Vented) DINII� G/GREAT 30 Blown 588 ft2 0.1 Wood 8 Under Attic (Vented) KITCHEN 30 Blown 209 ft2 0.1 Wood 9 Under Attic (Vented) BATH 30 Blown 50 fl:2 0.1 Wood 10 Under Attic (Vented) 1HALL 30 Blown 25 ft2 0.1 Wood 11 Under Attic (Vented) FOYER 30 Blown 92 ft2 0.1 Wood 12 Under Attic (Vented) BEDROOM 3 30 Blown 169 ft2 0.1 Wood WALLS Adjacent Ornt In Wall 141pe Lavity Width Space le Et In Height Et In Area Sheathing Framing R-1/ahle Ernction Solar Ahqnr Below rrarfe% 1 NE=>W Exterior Concrete Block - Ext InsMASTER BE 4.1 16 1 0 8 0 128.0 ft2 0 0 0.5 0 2 SW=>E Exterior Concrete Block - Ext IndMASTER BE 4.1 7 0 8 0 56.0 ft2 0 0 0.5 0 1 3 NW=>S Exterior Concrete Block - Ext IndM ASTER BE 4.1 14 0 8 0 112.0 fl:2 0 0 0.5 0 I 4 NE=>W Exterior Concrete Block - Ext IndMASTER BA 4.1 8 1 0 8 0 64.0 ft2 0 0 0.5 0 1 4/16/2018 8:46 PM EnergyGauge9) USA - FlaRes2017 Section R405.4.1 Compliant Software Page 3 of 5 FORM R405-2017 I WALLS 9 Adjacent Ornt In VV:;" 4pe Space Cavity Width R--Val-le Et 113 Height Et In Area Sheathing Framing Solar RA/mIlle Eraction AhSor Below r4rarjp% 5 NE=>W Exterior Concrete Block - Ext InsulM. BAT H 4.1 7 0 8 0 56.0 ft2 0 0 0.5 0 6 NE=>W Exterior Concrete Block - Ext InQEDRO 9 M 2 4.1 12 0 8 0 96.0 ft2 0 0 0.5 0 7 SW=>E Exterior Concrete Block - Ext InaJNING/GRE 4.1 30 0 8 0 240.0 ft2 0 0 0.5 0 8 NW=>S Exterior Concrete Block - Ext IndANING/GRE 4.1 20 0 8 0 160.0 ft2 0 0 0.5 0 9 SW=>E Exterior Concrete Block - Ext InsuKTCH N 4.1 11 0 8 0 88.0 ft2 0 0 0.5 0 10 NE=>W Exterior Concrete Block - Ext Insul BAT 4.1 5 0 8 0 40.0 ft2 0 0 0.5 0 11 SE=>N Exterior Concrete Block - Ext Insul Foy R 4.1 8 0 8 0 64.0 ft2 0 0 0.5 0 12 SW=>E Exterior Concrete Block - Ext Insul FOYER 4.1 1 0 8 0 8.0 ft2 0 0 0.5 0 I 13 NE=>W Exterior Concrete Block - Ext InRIEDIRO OM3 4.1 13 0 8 0 104.0 ft2 0 0 0.5 0 14 SW=>E Exterior Concrete Block - Ext InfiEDR OM 3 4.1 1 0 8 0 8.0 ft2 0 0 0.5 0 15 N=>SW Garage Frame - Wood BEDROOM 3 11 26 8 208.0 ft2 0.23 0.5 0 DOORS V # Ornt Door Type Spa�e Storms U-Value Width Height Area Ft In Ft In I SE=>N Insulated FOYER None .39 3 3 6 8 21.7 ft2 WINDOWS Orientation shown i the entered orientation (=>) changed to Worst Case. V Wall I Overhang # Ornt ID Frame Panes Nr- RC U-Factor SHGC Imp Area Depth Separation Int Shade Screening 1 NW=>S 3 Metal Low-E Single Yes 0.63 0.25 N 32.4 ft2 1 ft 0 in I ft 4 in Drapes/blinds Exterior 5 2 NE=>W 5 Metal Low-E Single 0.25 N 6.9 ft2 1 ft 0 in 1 ft 4 in None None 3 NE=>W 6 Metal Low-E Single as 0.63 0.25 N 16.2 ft2 1 ft0in 1 ft4in None None 4 SW=>E 7 Metal Low-E Single es 0.63 0.25 N 39.8 ft2 1 ft0in 1 ft4in None None 5 NW=>S 8 Metal Low-E Single Yes 0.65 0.21 N 40.0 ft2 8 ft 0 in I ft 4 in None None 6 NE=>W 13 Metal Low-E Single Yes 0.63 0.25 N 16.2 ft2 1 ft 0 in 1 ft4 in Drapes/blinds Exterior 5 GARAGE V# Floor Area Ceiling Area' Exposed Wall Perimeter Avg. Wall Height Exposed Wall Insulation 1 806 ft2 806 ft2 26 ft 8 ft 11 INFILTRATION # Scope Method SL� CFM 50 ELA EqLA ACH ACH 50 1 Wholehouse Proposed ACH(50) .000356 1636.1 89.82 168.92 .2598 7 4/16/2018 8:46 PM EnergyGaugbo USA - FlaRes2017 Section R405.4.1 Compliant Software Page 4 of 5 FnRU R4n.,i-qn17 1HEATING SYSTEM y # System Type Subtype Efficiency Capacity Block Ducts 1 Electric Heat Pump/ Split HSPF:8.5 34.8 kBtu/hr I sys#1 I COOLING SYSTEM y # System Type Subtype Efficiency Capacity Air Flow SHR Block Ducts I Central Unit/ Split SEER: 15 34.8 kBtu/hr cfm 0.85 1 sys#1 1HOT WATER SYSTEM y # System Type SubType Location EF Cap Use SetPnt Conservation 1 Electric None Garage 0.97 40 gal 60.9 gal 120 deg None SOLAR HOT WATER SYSTEM V FSEC Collector Storage Cert # Company Name System Model # Collector Model # Area Volume FEF None None ft2 DUCTS -- Supply Return ---- Air CFM 25 CFM25 HVAC # V # Location R-Value Area Locatio I n Area Leakage Type Handler TOT OUT QN RLF Heat Cool 1 Attic 6 225 ft2 Atticl 65 ft2 Default Leakage Attic (Default) (Default) 1 1 1 TEMPERATURES Prograrnable Thermostat: Y Ceiling Fans: Cooling Jan Feb Mar Apr Jun Jul M:y Aug Sep Oct Nov Dec He H Jan Feb H Mar HX Apr Jun Jul i im y ri ri Aug ri S ri Oct Nov HX Dec H Ve Jan Feb Mar Apr May Jun Jul Aug S Oct Nov Dec Thermostat Schedule: HERS 2006 Reference Hours Schedule Type 1 2 3 4 5 6 7 8 9 10 11 12 Cooling (WD) AM 78 78 8 78 78 78 78 78 80 80 80 80 PM 80 80 78 78 78 78 78 78 78 78 78 78 Cooling (WEH) AM 78 78 78 78 78 78 78 78 78 78 78 78 PM 78 78 78 78 78 78 78 78 78 78 78 78 Heating (WD) AM 66 66 66 66 66 68 68 68 68 68 68 68 PM 68 68 68 68 68 68 68 68 68 68 66 66 Heating (WEH) AM 66 66 66 66 66 68 68 68 68 68 68 68 PM 68 68 68 68 68 68 68 68 68 68 66 66 4/16/2018 8:46 PM EnergyGauge@ USA - FlaRes2017 Section R405.4.1 Compliant Software Page 5 of 5 1 2617 - AIR BARRIER AND INSULATION INSPEC I ION COMPONENT CRITERIA ITABLE 402.4.1.1 AIR BARRIER AND INSULATION INSPECTION COMPONENT CRITERIA I Project Name: WYNNE THE WINDSOR IMPACT Builder Name: WYNNE DEVELOPMENT Street: THE WINDSOR Permit Office: ST. LUCIE COUNTY City, State, Zip: FT. PIERCE, FL, Permit Number: Owner: Jurisdiction: Design Location: FL, Fort Pierce COMPONENT AIR BARRIER UKI I MKIA INSULATION INSTALLATION CRITERIA General I A continuous air barrier shall be installed in the building envelope. Air -permeable insulation shall requirements The exterior thermal envelope conta I ins a continuous air barrier. Breaks or joints in the air barrier shall be sealed. not.be used as a sealing material. I The air barrier in any dropped ceiling/soffit shall be aligned with Ceiling/aftic The insulation in any dropped ceiling/soffit the insulation and any gaps in the air barrier shall be sealed. shall be aligned with the air barrier. Access openings, drop down stairs or knee wall doors to unconditioned attic spaces shall belsealed. Walls I The junction of the foundation and sill plate shall be sealed. Cavities within corners and headers of frame walls The junction of the top plate and thel top of exteriorwalls shall be shall be insulated by completely filling the cavity with sealed. a material having a thermal resistance of R-3 per inch Knee walls shall be sealed. minimum. Exterior thermal envelope insulation for framed walls shall be installed in substantial contact and continuous alignment with the air barrier. Windows, skylights The space between window/doorjplmbs and framing, and and doors skylights and framing shall be sea I led. Rim joists Rim joists shall include the air barrler. Rim joists shall be insulated. Floors The air barrier shall be installed ai any exposed edge of Floor framing cavity insulation shall be installed to (including insulation. maintain permanent contact with the underside of above -garage subfloor decking, or floor framing cavity insulation and cantilevered shall be permitted to be in contact with the top side floors) of sheathing, or continuous insulation installed on the underside of floor framing and extends from the bottom to the top of all -perimeter floor framing members. Crawl space walls Exposed earth in unvented crawi spaces shall be covered with Where provided instead of floor insulation, insulation a Class I vapor retarder with ov�rlapping joints taped. shall be permanently attached to the crawlspace walls. Shafts, penetrations Duct shafts, utility penetrations, I and flue shafts opening to exterior or unconditioned space!shall be sealed. Batts in narrow cavities shall be cut to fit, or narrow Narrow cavities cavities shall be filled by insulation that on installation readily conforms to the available cavity spaces. Garage separation Air sealing shall be provided be I 'tween the garage and conditioned spac as. Recessed lighting Recessed light fixtures installed' in the building thermal envelope Recessed light fixtures installed in the building shall be sealed to the drywall. thermal envelope shall be airtight and IC rated. Plumbing and wiring Batt insulation shall be cut neatly to fit around wiring and plumbing in exterior walls, or insulation that on installation readily conforms to available spare shall extend behind piping and wiring, Shower/tub The air barrier installed at exterior walls adjacent to showers and Exterior walls adjacent to showers and tubs shall on exterior wall tubs shall separate them fromithe showers and tubs. be insulated. Electricallphone box or The air barrier shall be installed behind electrical or communication exterior walls boxes or air -sealed boxes shall be installed. HVAC register boots HVAC register boots that peneltrate building thermal envelope shall be sealed to the sub -floor or �Irywall. Concealed I When required to be sealed, concealed fire sprinklers shall only be sprinklers sealed in a manner that is rec, ornmended by the manufacturer. Caulking or other adhesive s elalants shall not be used to fill voids between fire WrjaEler cover P, lates and walls or ceilincs- a. in addition, inspection of log walls shall be in accordance with the provisions of [CC-400. 1 4/16/2018 8:46 PM EnergyGauge@) USA - FlaRes20117 FBC 6th Edition (2017) Compliant Software Page 1 of 1 FORM R405-2017 ENERGY PERF RMANCE LEVEL (EPL) DIIS,IPLAY CARD ESTIMATED ENERGY PERFORMANCE INDEX 100 The lower the EnergyPe,rformance Index, the more efficient the home. I THE WINDSOR, FT. PIERCE, FL, 1 . New construction or existing 2. Single family or multiple family 3. Number of units, if multiple family 4. Number of Bedrooms 5. Is this a worst case? 6. Conditioned floor area (ft2) 7. Windows- Description a. U-Factor: SgI, U=0.63 SHGC: SHGC=0.25 b. U-Factor: SgI, U=0.65 SHGC: SHGC=0.21 c. U-Factor: N/A SHGC: d. U-Factor: N/A SHGC: Area Weighted Average Overhang Depth: Area Weighted Average SHGC: 8. Floor Types a. Slab -On -Grade Edge Insulation b. N/A c. N/A New (From Ph Single-family 1 3 Yes 1753 Area 1 ft2 111.36 1 ft2 40.7 ft2 ft2 2.850 ft. 0.239 1 1 Insulation Ai R=0.0 1753.00 ft2 R= ft2 R= ft2 I certify that this home has complied with the FloridE Construction through the above energy saving featu in this home before final inspection. Otherwise, a ni based on installed Code compliant features. Builder Signature: Address of New Home-<�-� 9. Wall Types a. Concrete Block - Ext Insul, Exterior b. Frame - Wood, Adjacent c. N/A d. N/A 10. Ceiling Types a. Under Attic (Vented) b. N/A c. N/A 11. Ducts a. Sup: Attic, Ret: Attic, AH: Attic 12. Cooling systems a. Central Unit 13. Heating systems a. Electric Heat Pump 14. Hot water systems a. Electric b. Conservation features None 15. Credits Energy Efficiency Code for Building as which will be installed (or exceeded) N EPL Display Card will be completed Date: �-A,-C� City/FL Z Insulation Area R=4.1 1224.00 ft2 R=1 1.0 208.00 ft2 R= ft2 R= ft2 Insulation Area R=30.0 1753.00 ft2 R= ft2 R= ft2 R ft2 6 225 kBtu/hr Efficiency 34.8 SEER:15.00 kBtu/hr Efficiency 34.8 HSPF:8.50 Cap: 40 gallons EF: 0.97 Pstat -tliE S 0 WE *Note: This is not a Building Energy Rating. If your Index is below 70, your home may qualify for energy efficient mortgage (EEM) incentives if you obtain a Florida EnergyGauge Rating. Email EnergyGauge tech support at techsupport@energygauge.com or see the E 9 1 ergyGauge web site at energygauge.com for information and a list of certified Raters. For information about the Florida Building Code, Energy Conservation, contact the Florida Building Commission's support staff. i **Label required by Section R303.1.3 of the Florida Building Code, Energy Conservation, if not DEFAULT. 4/16/2018 8:46 PM EnergyGaugeO USIA - FlaRes2017 - Section R405.4.1 Compliant Software Page 1 of 1 1