HomeMy WebLinkAboutENERGY EFFICIENCY CODEFORMf'R405-2017
FLORIDA ENERGY
EFFICIENCY CODE FOR BUILDING
CONSTRUCTION
Florida Department of Business and Professional Regulation - Residential Performance Method
I
Project Name: WYNNE THE WINDSOR IMPACT
Builder Name: WYNNE DEVELOPMENT
Street: THE WINDSOR
Permit Office: ST. LUCIE COUNTY
qity, State, Zip: FT. PIERCE, FL,
Owner:
Permit Number:
Jurisdiction:
Design Location: FL, Fort Pierce
County:: St. Lucie (Florida Climate Zone 2
1. New construction or existing
New (From Plans)
9. Wall Types (1432.0 sqft.)
Insulation Area
2. Single family or multiple family
Single-family
a. Concrete Block - Ext Insul, Exterior
R=4.1 1224.00 fl:2
b. Frame - Wood, Adjacent
R=l 1.0 208.00 ft'
3. Number of units, if multiple family
1
c. N/A
R= ft2
4. Number of Bedrooms
3
d. N/A
R= ft2
10. Ceiling Types (1753.0 sqft.)
Insulation Area
5. Is this a worst case?
Yes
a. Under Attic (Vented)
R=30.0 1753.00 fl:2
6. Conditioned floor area above grade (fl:2)
1753
b. N/A
R= ft2
Conditioned floor area below grade (fl:2)
0
c. N/A
R= ft2
11. Ducts
R fl:2
7. Windows(151.4 sqft.) Description
Area!
a. Sup: Attic, Ret: Attic, AH: Attic
6 225
a. U-Factor: Sgl, U=0.63
Ill . 36 ft-
SHGC: SHGC=0.25
b. U-Factor: Sgl, U=0.65
40.0� ft2
12. Cooling systems
kBtu/hr Efficiency
SHGC: SHGC=0.21
a. Central Unit
34.8 SEER:15.00
c. U-Factor: N/A
ft2
SHGC:
110
13. Heating systems
kBtu/hr Efficiency
d. U-Factor: N/A
ft2
a. Electric Heat Pump
34.8 HSPF:8.50
SHGC:
Area Weighted Average Overhang Depth: 2.8 ft.
Area Weighted Average SHGC:
0.236
14. Hot water systems
I
a. Electric
Cap: 40 gallons
8. FloorTypes (1753.0 sqft.)
Insulation Ai
EF: 0.970
a. Slab -On -Grade Edge Insulation
R=0.0 1753 - fl:2
b. Conservation features
b. N/A
R= ft2
None
c. N/A
R= ft2
15. Credits
Pstat
Glass/Floor Area: 0.086
Total Prop I sed Modi led Loads: 53.83
PASS
Total Baseline Loads: 53.85
1
1 hereby certify that the plans and specifications co e Ld by
V Zy
Review of the plans and
E S
this calculation are in compliance with the Florida En
specifications covered by this
z *t�
Code.
calculation indicates compliance
with the Florida Energy Code.
vs
PREPM BY' '!4 �2� >�:K_ 1../
DATE.
Af le AK�V
Before construction is COMPleted
this building will be inspected for
compliance with Section 553.908
I hereby certify that this building, as de
,signed,
the Florida Energ Code
is in c ompliance
Florida Statutes.
with
WME
OWNERI���.
BUILDING OFFICIAL:
DATE: VQ5
DATE:
- I
- Compliance requires certification by the air
certified factory -sealed in accordance with I
- Compliance requires an Air Barrier and Insu
envelope leakage test report with envelope le
unit manufacturer that the air handier enclosure qualifies as
.1.
Inspection Checklist in accordance with R402.4.1.1 and this project requires an
no greater than 7.00 ACH50 (R402.4.1.2).
4/16/2018 8:46 PM EnergyGauge@JUSA - FlaRes2017 Section R405.4.1 Compliant Software Page 1 of 5
FORM R405-2017
PROJECT
Title: WYNNE THE WINDSOR IM
Bedrooms: 3
Address Type:
Street Address
Building Type: User
Conditi loned Area: 1753
Lot #
Owner Name:
I
Total Stories: 1
Block/Subdivision:
#of Units: 1
Worst I Case: Yes
PlatBook:
Builder Name: WYNNE DEVELOPMENT
Rotate Angle: 225
Street:
THE WINDSOR
Permit Office: ST. LUCIE COUNTY
Cross entilation: No
County:
St. Lucie
Jurisdiction:
Whole House Fan: No
City, State,
Zip:
FT. PIERCE,
Family Type: Single-family
FL,
New/Existing: New (From Plans)
Comment:
CLIMATE
V
Design Temp
Int Design Temp
Heating
Design Daily Temp
Design Location TMY Site
97.5%
2.5%
Winter
Summer Degree Days Moisture
Range
FL, Fort Pierce FL—VERO—BEACH—MUNI 39
90
70
75
299
62
Low
I BLOCKS
Number Name Area
Volume
I
1 Entire House 1753
14024
SPACES
Number Name Area
Volume Kitchen Occupants
Bedrooms
Infil ID
Finished Cooled
Heated
1 MASTER BEDROO 224
1792 No
0
1
1
Yes
Yes
Yes
2 WIC 63
504 No
0
1
No
Yes
Yes
3 MASTER BATH 56
448 No
0
1
Yes
Yes
Yes
4 M. BATH 61
488 No
0
1
Yes
Yes
Yes
5 LAUDRY 36
288 No
0
1
No
Yes
Yes
6 BEDROOM 2 180
144 1 No
0
1
1
Yes
Yes
Yes
7 DINING/GREAT R 588
470 No
2
1
Yes
Yes
Yes
8 KITCHEN 209
1672 Yes
0
1
Yes
Yes
Yes
9 BATH 50
400 No
0
1
Yes
Yes
Yes
10 HALL 25
200 No
0
1
No
Yes
Yes
11 FOYER 92
736 No
0
1
Yes
Yes
Yes
12 BEDROOM 3 169
135, No
0
1
1
Yes
Yes
Yes
FLOORS
y# Floor Type Space
Perimeter Perimeter R-Value
Area
Joist R-Value
Tile Wood
Carpet
1 Slab -On -Grade Edge Insulatio MASTER BEbRO 37 ft 0
224 ft2
----
0 1
0
2 Slab -On -Grade Edge Insulatio WIC 1 ft 0
63 ft2
----
0 1
0
3 Slab -On -Grade Edge Insulatio MASTER BATH 8 ft 0
56 ft2
----
0 1
0
4 Slab -On -Grade Edge Insulatio M. BAT� 7 ft 0
61 ft2
----
0 1
0
5 Slab -On -Grade Edge Insulatio LAUDR�, 1 ft 0
1
36 ft2
----
0 1
0
4/16/2018 8:46 PM EnergyGauge@ USA - FlaRes2017 Section R405,4,1 Compliant Software Page 2 of 5
FORM R405-2017
FLOORS
v# Floor Type
Space Perimeter Perimeter R-Value
Area
Joist R-Value
Tile
Wood Carpet
6 Slab -On -Grade Edge Insulatio
BEDROOM 2 12 ft
0
180 ft2
----
0
1
0
7 Slab -On -Grade Edge Insulatio
DINING/GREAT 50ft
0
588 ft2
----
0
1
0
8 Slab -On -Grade Edge Insulatio
KITCHEN 11 ft
0
209 ft2
----
0
1
0
9 Slab -On -Grade Edge Insulatio
BATH 5 ft
0
50 ft2
----
0
1
0
10SIab-On-Grade Edge Insulatio
HALL 1 ft
0
25 ft2
----
0
1
0
1 1SIab-On-Grade Edge Insulatio
FOYER 9 ft
0
92 ft2
----
0
1
0
12SIab-On-Grade Edge Insulatio
BEDROOM 3 14 ft
0
169 lit'
----
0
1
0
ROOF
Roof
Gable
Roof
Solar SA
Emitt
Emitt
Deck
Pitch
# Type Materials
Area
Area
Color
Absor. Tested
Tested
Insul.
(deg)
1 Gable or Shed
Metal 1847 ft2
292 fl:2
Light
0.6
No
0.9
No
0
18.4
ATTIC
V#
Type
Ventilation Vent Ratio (1
in)
Area
RBS
IRCC
1 Full attic
Vented
150
1753 ft2
N
N
CEILING
V# Ceiling Type
S 'Pace
R-Value
Ins Type
Area
Framing Frac Truss Type
1 Under Attic (Vented)
MAS7, BEDRO
30
Blown
224 ft2
0.1
Wood
2 Under Attic (Vented)
C
30
Blown
63 ft2
0.1
Wood
3 Under Attic (Vented)
rMASTER BATH
30
Blown
56 ft2
0.1
Wood
4 Under Attic (Vented)
M -1 BATH
30
Blown
61 ft2
0.1
Wood
5 Under Attic (Vented)
LAUDRY
30
Blown
36 ft2
0.1
Wood
6 Under Attic (Vented)
BED ROOM 2
30
Blown
180 ft2
0.1
Wood
I
7 Under Attic (Vented)
DINII� G/GREAT
30
Blown
588 ft2
0.1
Wood
8 Under Attic (Vented)
KITCHEN
30
Blown
209 ft2
0.1
Wood
9 Under Attic (Vented)
BATH
30
Blown
50 fl:2
0.1
Wood
10 Under Attic (Vented)
1HALL
30
Blown
25 ft2
0.1
Wood
11 Under Attic (Vented)
FOYER
30
Blown
92 ft2
0.1
Wood
12 Under Attic (Vented)
BEDROOM 3
30
Blown
169 ft2
0.1
Wood
WALLS
Adjacent
Ornt In Wall 141pe
Lavity Width
Space le Et In
Height
Et In
Area
Sheathing Framing
R-1/ahle Ernction
Solar
Ahqnr
Below
rrarfe%
1 NE=>W Exterior Concrete Block - Ext InsMASTER BE 4.1 16
1
0 8
0
128.0 ft2
0
0
0.5
0
2 SW=>E Exterior Concrete Block - Ext IndMASTER BE 4.1 7
0 8
0
56.0 ft2
0
0
0.5
0
1
3 NW=>S Exterior Concrete Block - Ext IndM ASTER BE 4.1 14
0 8
0
112.0 fl:2
0
0
0.5
0
I
4 NE=>W Exterior Concrete Block - Ext IndMASTER BA 4.1 8
1
0 8
0
64.0 ft2
0
0
0.5
0
1
4/16/2018 8:46 PM EnergyGauge9) USA - FlaRes2017 Section R405.4.1 Compliant Software Page 3 of 5
FORM R405-2017
I
WALLS
9
Adjacent
Ornt In VV:;" 4pe Space
Cavity Width
R--Val-le Et 113
Height
Et In
Area
Sheathing Framing Solar
RA/mIlle Eraction AhSor
Below
r4rarjp%
5
NE=>W Exterior
Concrete Block - Ext InsulM. BAT H
4.1 7
0
8 0
56.0 ft2
0
0
0.5
0
6
NE=>W Exterior
Concrete Block - Ext InQEDRO 9 M 2
4.1 12
0
8 0
96.0 ft2
0
0
0.5
0
7
SW=>E Exterior
Concrete Block - Ext InaJNING/GRE
4.1 30
0
8 0
240.0 ft2
0
0
0.5
0
8
NW=>S Exterior
Concrete Block - Ext IndANING/GRE
4.1 20
0
8 0
160.0 ft2
0
0
0.5
0
9
SW=>E Exterior
Concrete Block - Ext InsuKTCH N
4.1 11
0
8 0
88.0 ft2
0
0
0.5
0
10
NE=>W Exterior
Concrete Block - Ext Insul BAT
4.1 5
0
8 0
40.0 ft2
0
0
0.5
0
11
SE=>N Exterior
Concrete Block - Ext Insul Foy R
4.1 8
0
8 0
64.0 ft2
0
0
0.5
0
12
SW=>E Exterior
Concrete Block - Ext Insul FOYER
4.1 1
0
8 0
8.0 ft2
0
0
0.5
0
I
13
NE=>W Exterior
Concrete Block - Ext InRIEDIRO OM3
4.1 13
0
8 0
104.0 ft2
0
0
0.5
0
14
SW=>E Exterior
Concrete Block - Ext InfiEDR OM 3
4.1 1
0
8 0
8.0 ft2
0
0
0.5
0
15
N=>SW Garage
Frame - Wood BEDROOM 3
11 26
8
208.0 ft2
0.23
0.5
0
DOORS
V
# Ornt
Door Type Spa�e
Storms
U-Value
Width
Height
Area
Ft
In
Ft In
I SE=>N Insulated FOYER
None
.39
3
3
6 8
21.7 ft2
WINDOWS
Orientation shown i the entered orientation (=>) changed to Worst Case.
V
Wall
I
Overhang
# Ornt ID
Frame Panes Nr- RC U-Factor
SHGC
Imp
Area
Depth
Separation
Int Shade
Screening
1 NW=>S 3
Metal Low-E Single Yes
0.63 0.25
N
32.4 ft2
1 ft 0 in
I ft 4 in
Drapes/blinds
Exterior 5
2 NE=>W 5
Metal Low-E Single
0.25
N
6.9 ft2
1 ft 0 in
1 ft 4 in
None
None
3 NE=>W 6
Metal Low-E Single as
0.63 0.25
N
16.2 ft2
1 ft0in
1 ft4in
None
None
4 SW=>E 7
Metal Low-E Single es
0.63 0.25
N
39.8 ft2
1 ft0in
1 ft4in
None
None
5 NW=>S 8
Metal Low-E Single Yes
0.65 0.21
N
40.0 ft2
8 ft 0 in
I ft 4 in
None
None
6 NE=>W 13
Metal Low-E Single Yes
0.63 0.25
N
16.2 ft2
1 ft 0 in
1 ft4 in
Drapes/blinds
Exterior 5
GARAGE
V#
Floor Area Ceiling Area' Exposed Wall Perimeter
Avg. Wall Height
Exposed Wall Insulation
1 806 ft2 806 ft2
26 ft
8 ft
11
INFILTRATION
# Scope Method SL� CFM 50 ELA
EqLA
ACH
ACH
50
1 Wholehouse Proposed ACH(50) .000356 1636.1 89.82
168.92
.2598
7
4/16/2018 8:46 PM EnergyGaugbo USA - FlaRes2017 Section R405.4.1 Compliant Software Page 4 of 5
FnRU R4n.,i-qn17
1HEATING SYSTEM
y #
System Type
Subtype Efficiency
Capacity
Block
Ducts
1
Electric Heat Pump/
Split HSPF:8.5
34.8 kBtu/hr
I
sys#1
I COOLING SYSTEM
y #
System Type
Subtype Efficiency
Capacity
Air Flow
SHR
Block
Ducts
I
Central Unit/
Split SEER: 15 34.8 kBtu/hr cfm
0.85
1
sys#1
1HOT WATER SYSTEM
y #
System Type
SubType
Location EF Cap Use
SetPnt
Conservation
1
Electric
None
Garage 0.97 40 gal 60.9 gal
120 deg
None
SOLAR HOT WATER SYSTEM
V FSEC
Collector
Storage
Cert # Company Name
System Model # Collector Model
# Area
Volume
FEF
None None
ft2
DUCTS
-- Supply
Return ----
Air
CFM 25
CFM25
HVAC #
V #
Location R-Value Area
Locatio I n Area Leakage Type
Handler
TOT
OUT
QN
RLF
Heat Cool
1
Attic
6 225 ft2
Atticl 65 ft2 Default Leakage
Attic
(Default)
(Default)
1 1
1 TEMPERATURES
Prograrnable Thermostat: Y
Ceiling Fans:
Cooling
Jan Feb
Mar
Apr Jun Jul
M:y
Aug
Sep
Oct
Nov
Dec
He
H
Jan Feb
H
Mar
HX
Apr Jun Jul
i im y ri ri
Aug
ri
S
ri
Oct
Nov
HX
Dec
H
Ve
Jan Feb
Mar
Apr May Jun Jul
Aug
S
Oct
Nov
Dec
Thermostat Schedule:
HERS 2006 Reference
Hours
Schedule Type
1
2 3 4 5 6
7
8
9
10
11
12
Cooling (WD)
AM
78
78 8 78 78 78
78
78
80
80
80
80
PM
80
80 78 78 78 78
78
78
78
78
78
78
Cooling (WEH)
AM
78
78 78 78 78 78
78
78
78
78
78
78
PM
78
78 78 78 78 78
78
78
78
78
78
78
Heating (WD)
AM
66
66 66 66 66 68
68
68
68
68
68
68
PM
68
68 68 68 68 68
68
68
68
68
66
66
Heating (WEH)
AM
66
66 66 66 66 68
68
68
68
68
68
68
PM
68
68 68 68 68 68
68
68
68
68
66
66
4/16/2018 8:46 PM EnergyGauge@ USA - FlaRes2017 Section R405.4.1 Compliant Software Page 5 of 5
1
2617 - AIR BARRIER AND INSULATION INSPEC I ION COMPONENT CRITERIA
ITABLE 402.4.1.1
AIR BARRIER AND INSULATION INSPECTION COMPONENT CRITERIA
I
Project Name: WYNNE THE WINDSOR IMPACT Builder Name: WYNNE DEVELOPMENT
Street: THE WINDSOR Permit Office: ST. LUCIE COUNTY
City, State, Zip: FT. PIERCE, FL, Permit Number:
Owner: Jurisdiction:
Design Location: FL, Fort Pierce
COMPONENT
AIR BARRIER UKI I MKIA
INSULATION INSTALLATION CRITERIA
General
I
A continuous air barrier shall be installed in the building envelope.
Air -permeable insulation shall
requirements
The exterior thermal envelope conta I ins a continuous air barrier.
Breaks or joints in the air barrier shall be sealed.
not.be used as a sealing material.
I
The air barrier in any dropped ceiling/soffit shall be aligned with
Ceiling/aftic
The insulation in any dropped ceiling/soffit
the insulation and any gaps in the air barrier shall be sealed.
shall be aligned with the air barrier.
Access openings, drop down stairs or knee wall doors to
unconditioned attic spaces shall belsealed.
Walls
I
The junction of the foundation and sill plate shall be sealed.
Cavities within corners and headers of frame walls
The junction of the top plate and thel top of exteriorwalls shall be
shall be insulated by completely filling the cavity with
sealed.
a material having a thermal resistance of R-3 per inch
Knee walls shall be sealed.
minimum.
Exterior thermal envelope insulation for framed walls
shall be installed in substantial contact and
continuous alignment with the air barrier.
Windows, skylights
The space between window/doorjplmbs and framing, and
and doors
skylights and framing shall be sea I led.
Rim joists
Rim joists shall include the air barrler.
Rim joists shall be insulated.
Floors
The air barrier shall be installed ai any exposed edge of
Floor framing cavity insulation shall be installed to
(including
insulation.
maintain permanent contact with the underside of
above -garage
subfloor decking, or floor framing cavity insulation
and cantilevered
shall be permitted to be in contact with the top side
floors)
of sheathing, or continuous insulation installed on
the underside of floor framing and extends from the
bottom to the top of all -perimeter floor framing
members.
Crawl space walls
Exposed earth in unvented crawi spaces shall be covered with
Where provided instead of floor insulation, insulation
a Class I vapor retarder with ov�rlapping joints taped.
shall be permanently attached to the crawlspace walls.
Shafts, penetrations
Duct shafts, utility penetrations, I and flue shafts opening to
exterior or unconditioned space!shall be sealed.
Batts in narrow cavities shall be cut to fit, or narrow
Narrow cavities
cavities shall be filled by insulation that on
installation readily conforms to the available cavity
spaces.
Garage separation
Air sealing shall be provided be I 'tween the garage and conditioned spac
as.
Recessed lighting
Recessed light fixtures installed' in the building thermal envelope
Recessed light fixtures installed in the building
shall be sealed to the drywall.
thermal envelope shall be airtight and IC rated.
Plumbing and wiring
Batt insulation shall be cut neatly to fit around wiring
and plumbing in exterior walls, or insulation that on
installation readily conforms to available spare shall
extend behind piping and wiring,
Shower/tub
The air barrier installed at exterior walls adjacent to showers and
Exterior walls adjacent to showers and tubs shall
on exterior wall
tubs shall separate them fromithe showers and tubs.
be insulated.
Electricallphone box or
The air barrier shall be installed behind electrical or communication
exterior walls
boxes or air -sealed boxes shall be installed.
HVAC register boots
HVAC register boots that peneltrate building thermal envelope shall
be sealed to the sub -floor or �Irywall.
Concealed
I
When required to be sealed, concealed fire sprinklers shall only be
sprinklers
sealed in a manner that is rec, ornmended by the manufacturer.
Caulking or other adhesive s elalants shall not be used to fill voids
between fire WrjaEler cover P, lates and walls or ceilincs-
a. in addition, inspection of log walls shall be in accordance with the provisions of [CC-400.
1
4/16/2018 8:46 PM EnergyGauge@) USA - FlaRes20117 FBC 6th Edition (2017) Compliant Software Page 1 of 1
FORM R405-2017
ENERGY PERF RMANCE LEVEL (EPL)
DIIS,IPLAY CARD
ESTIMATED ENERGY PERFORMANCE INDEX 100
The lower the EnergyPe,rformance Index, the more efficient the home.
I
THE WINDSOR, FT. PIERCE, FL,
1 . New construction or existing
2. Single family or multiple family
3. Number of units, if multiple family
4. Number of Bedrooms
5. Is this a worst case?
6. Conditioned floor area (ft2)
7. Windows- Description
a. U-Factor: SgI, U=0.63
SHGC: SHGC=0.25
b. U-Factor: SgI, U=0.65
SHGC: SHGC=0.21
c. U-Factor: N/A
SHGC:
d. U-Factor: N/A
SHGC:
Area Weighted Average Overhang Depth:
Area Weighted Average SHGC:
8. Floor Types
a. Slab -On -Grade Edge Insulation
b. N/A
c. N/A
New (From Ph
Single-family
1
3
Yes
1753
Area 1 ft2
111.36
1 ft2
40.7 ft2
ft2
2.850 ft.
0.239 1 1
Insulation
Ai
R=0.0
1753.00 ft2
R=
ft2
R=
ft2
I certify that this home has complied with the FloridE
Construction through the above energy saving featu
in this home before final inspection. Otherwise, a ni
based on installed Code compliant features.
Builder Signature:
Address of New Home-<�-�
9. Wall Types
a. Concrete Block - Ext Insul, Exterior
b. Frame - Wood, Adjacent
c. N/A
d. N/A
10. Ceiling Types
a. Under Attic (Vented)
b. N/A
c. N/A
11. Ducts
a. Sup: Attic, Ret: Attic, AH: Attic
12. Cooling systems
a. Central Unit
13. Heating systems
a. Electric Heat Pump
14. Hot water systems
a. Electric
b. Conservation features
None
15. Credits
Energy Efficiency Code for Building
as which will be installed (or exceeded)
N EPL Display Card will be completed
Date: �-A,-C�
City/FL Z
Insulation
Area
R=4.1
1224.00 ft2
R=1 1.0
208.00 ft2
R=
ft2
R=
ft2
Insulation
Area
R=30.0
1753.00 ft2
R=
ft2
R=
ft2
R ft2
6 225
kBtu/hr Efficiency
34.8 SEER:15.00
kBtu/hr Efficiency
34.8 HSPF:8.50
Cap: 40 gallons
EF: 0.97
Pstat
-tliE S
0
WE
*Note: This is not a Building Energy Rating. If your Index is below 70, your home may qualify for energy efficient
mortgage (EEM) incentives if you obtain a Florida EnergyGauge Rating. Email EnergyGauge tech support at
techsupport@energygauge.com or see the E 9 1 ergyGauge web site at energygauge.com for information and a list of
certified Raters. For information about the Florida Building Code, Energy Conservation, contact the Florida Building
Commission's support staff. i
**Label required by Section R303.1.3 of the Florida Building Code, Energy Conservation, if not DEFAULT.
4/16/2018 8:46 PM EnergyGaugeO USIA - FlaRes2017 - Section R405.4.1 Compliant Software Page 1 of 1
1