SLOWER DOOR'
House infiltratio
Prescriptive and
07 q-z--
ient Services
ilation Division
RECEIVED
1201
Fax: 772-462-6443 APR,: 0 9 70110
PerMitting DepWrper)t. API
'ST FORM . St. Lucie Count� Permitt (OMM
Test Certification St
erformance Method
Date: Permi
Contractor: 61)1
Oe- I e- f m, e
Job Address: at r C je- 1 0 A
#: 1 9 0 + - 0 —) LH-
le. FL 31f
Construction: PqNew Construction — Complete Existing — After Addition
House Infiltration Test Results SLL Climate Zone 2
CFM (50) = Jo58 Test Date:
,Volume 11:3 4
ACH (50) = CFM (50) x 66 / Volume Mechanical Ventilation required less than 3 ACH
Passing results must be & ACH (50) or less yso Pass ( ) Fall
FBC, Energy
The building or dwelling unit shall be tested and verified as having an air leakage rate of not exceeding 2 air changes per
hour in Climate Zone 1, 2 and 3 air changes per hou in Climate Zones 3 through 8. Testing shall be conducted with a
blower door at a pressure of 0.2 inches w. g. (50 Pascals). Testing shall be conducted by either individuals as defined in
Section 553.993(5) or (7), Florida Statutes or inclivid als licensed as set forth in Section 489.105 (3)(f), (g) or (1) or an
approved third party. A written report of the result�of the test shall be signed by the party' conducting the test and
provided to the code official. Testing shall be performed at any time after creation of all penetrations of the building
thermal envelope. I
F13C, Resident1211
Where the air infiltration rate of a dwelling unit is less than 3 air changes per hour when tested with a blower door at a
pressure of 0.2 inch w. c. (50 Pa) in accordance wit `1 1 Section R402.4.1.2 of the Florida Building Code, Energy Conservation
the dwelling unit shall be provided with whole -house mechanical ventilation in accordance with Section M1507.3.
Testine Comoanv
Company Name: Pro -Duct Services
Address: 1915 Rio Vista Drive, Ft. Pierce, FL 34949
I hereby certifV that the above House Infiltration reiults demonstrate compliance with F13C Energy Conservation
requirements in accordance with Se;tiqn R402.4.1.2 Climate Zone 2.
r,
Signature:
Printed Name: Martin Klein
License/Certification #: 5061633