HomeMy WebLinkAboutBUILDING PLAN12 'H, Finish Columns with 5/8" thick cut coral finished stucco bands Gulf Coast Suppig and MFG 5v Crimp Metal roofing FL 3111"1.12 U go. 5v crimp metal roofing attached to plgwood anick using #9 x 1.5" wood screws with self sealing washer at 12" ii.c. max spacing over ASTM D ftgpe 2) 30 lb felt underlayment installed with min. 4 side laps and 6" end (ape fastened with corrosion resistant tin caps and with 1.25" ring shank nails spaced L" o.c. at all laps and two staggered . rows 12" o.c. in field. Attach deck to trusses using attachment detai on this sheet 5/8" thick light textured L_J stucco on tgpical concrete a block construction ------------------------- da, "Co 400 slow III -omqw4mlocp saw Gam lilic 5/8" thick x 8"Lu cut RIGHT ELEVATION coral finished 5tuq I co bands fqUnQja!4I' 146 A69 ST. LUCIE COUNTY BUILDING DIVISION REVIEWED FOR COMPI��E REVIE D Y DA E T �4_ 4ADBP �IT �BEKEPT�DNJOS THW Ill AND ALL ROKW 1111110111� PLAN S E R M S Aft SUItZIOTTO ANY CONRECTION SITE OR NO INSPECTION(S) WILL BE MADE RI DY RU IMPECTORS TH!' T MAI 4CCEVeAN IN OnDER TO r ­� COVL� WITH ALL AMQU C, ­�t CONCEALED FASTENERS OR ATTACHMINn ARE THE RESPONSIBILn OF I HE CONTRAC I OR OF RECORD 12 aiI FILE 00 1 PY 4 [SLOPE _,wom SCALE: 1/4" = 1'-0' Gulf Coast Supplil. and MFG 5v Crimp Metal roofing FL UU51.12 2� a. Sv crimp metal roofing attached to plilwood deck using #9 x 1.5" wiI screws wit . h self strahng washer at 12" o.c. max spacing over ASTM 0 (tgpe 2) 30 lb felt underlagment. installed with min. 4 aide laps and I" end laps fastened with corrosion resistant tin caps and with 1.25" ring shank nails %aced 6" o.c. at all laps and two staggered . rows 12" o.c. in field. Attach ck to trusses using attachment detail an this sheet 12 SLOPE 14 Gulf Coast Supplg and MFG 5v Crimp Metal roofing FL 111:1101.12 24 go. 5v crimp metal roofing attached to plgwood -deck uring #9 x 1.5' wood screws with self sealing washer at 12" o.c. max spacing over ASTM D (tgpe 2) 30 lb felt underlagment installed with min. 4, side.laps and 6" and laps fastened with corrosion resistant tin caps and all 1.25 ring shank nails spaced 4" o.c. at all laps and two staggered rows 12" o.c. in field. Attach deck to trusses using attachment detai on this sheet 12 4 1 SLq�� W-16 T.O.B. �H, 0'-0" Finished Floor - - - - - - - - - - I r S/8" thick light textured = inisfi C c i I 111 11 :1 1 1 1� 5 _10 /8" thick cut coi al Stucco on t9pical concrete Finished stucco bands block construction ELE\/ATION NOTES: REAR ELEVATION - Overhangs at I`0" unless otherwise noted on Roof Fldn - Roof pitch at 4:12 unless otherwise noted - Ang changes to this plan shall be submitted to the architect for approval in writing prior to starting construction. - Return ALL Stucco Bands into Window or Door. 12 5�8" thick x: 8"w cut El coral finished stucco 6,/8" thick light textured Stucco on tgpical concrete block construction Finished Floor -- - - - - - - - - - - - - - - - - - - - - - - - - - - - - LEFT ELEVATkDN SCALE: 114' 1'-0' Product Approval Submittal Affidavit Opening Schedule Swing Doors, Overhead Doors, SUding D Windows & Skylights Opening Type NOA/I NUMIM Product Model # Manufacturer Glass Attachment method TEST EE ir tion D% a a Design Pressure of Approved Tests 1.2.3 t4 FLU 239.3 Single Hung SH-100 Impact PGT 5/141, 114' din. tW2 w/ min. 1 3/8" penetration to be spaced per pr act approval. Contractor *hall adhere to min. edge distances specified in Product approval 80.0 PSF A 16-0330.02 Overhead Garage Door Model 824/811 9'-4" max width IIII max height DAB X x 6' *Tr OPP, )1! 91 Xt A 8 6. Hit SI FI bI �dlr*4Pdl "-.M Vill -Mhmt Left 10-9-21 +1 50.0/-40.0 psf 14614.1 Fiberglass Design Pro/ Smooth Pro Jeld-Wen Elco 1/4' din. ta" with win 1.25' embedment at 3' max from corners and 115' oc, I ther-fter in head and jambs. 50.0 PSIF 1C FLU 251.6 Sliding Glass Door Series 110 SGD PGT 1' nom Tqpe "GSAO lllq' a 411L topcons In/ min. penetration to be aw 2. product approval. Contractor viliall adhere to 11w sift 2 is g distanI specified in Product approval SIF Product NOA/I NMWER Model # Manufacturer Attachment Method S S rat tion DaReT of Design Pressure Approved Tests Mullions FL# 241.1 1' x 2 3/4' x .315' PGT ristall er fastener tgpe and spacings shown in Table iA and IB !n procruct approval on sheet 5 of 22, 1+ 58.0 PSr- Roof FLU 111.51.12 5v Crimp Metal Roofing Gulf Coast S PPIg and manufacturing 116 ga. 5v crimp metal roofing attached to plilwood deck using 49 x 1.5" sood screws with sell sealing washer at 12' o.c. max spacing over ASTM D (tilipe 2) 30 Ib felt underlailiment installed with min. 4 side laps and A" end laps Fastened with corrosion resistant tin caps and with 1.25' ring *Imk nails rced 6" ux. at all lop and two ate red rows 12' o.c. in field. Attach ck to trusses u&N attachment detailgan roof plan 108.5 FSF Siding Stucco an Block Soffit FL# 12198.3 Model T4 12- vented ving] Soffit Kagcan Install using 2" x 2' battens at 40 o.c. screwed to soffit framing using #8 x 3* wood screws at each truss, Install soffit to battens using 0,12" din, x 1.5" Iona ring shark III with 3/8" ad, head, +�S.O/-35.0 5 F Hurricane Panels 24 Gauge Storm Panels Global Protection Products LLC Instal /24ddi. solid set lead anchors with 1/4' dia.-20 x: 1,51 long ISSusinscridu a combo. with Neoprene washer at 12 1/2' o.c. along the bottom and 13' o.c. at the top 45.0 PSIF I have reviewed the above and approved it by, my seal below. ( Architect or Engineer of Record 6/8" thick X 8"Lu Cut --- coral finished stucco bands 2' x .4" top platel 11 1/2" drgwall ceiling an truss bottom cord 1/2" dr9wall on 2" x: 4' studs at 16" o.c. base -board ------- \ 11 11 ,, 2" x 4" P.T. bottom plate ',, 4" concrete slab with fibermesh OR 12 -4 1 SLOPE SCALE. 114" = 1'-0" Gulf Coast Suppig and MFG 5V Crimp Metal roofir;LPI #11451.12 2( go- 5v crim,% metal roofing attached to p[qwood ck using #9 x 1.54 woo screws wit ad. -If sealing washer at 12" o.c. max spacing over ASTM 0 (tope 2) 30 lb felt uriderlagment installed with min. 4 side laps and V' end laps fastened with corrosion resistant tin caps and with 1.2511 ring shank nails %aced 4" o.c. ateall laps and two staggered . rows 12" o,c. in Field- Attach dick to trundles u Ing attachment datai on this sheet 5/8" thick x 8"w cut coral finished stucco bands 1/8" Thick cut coral stucco over paper backed wire lath nailed to substrate through one lager of 15 lb felt using Sid nails. Substrate to be 19/S2' CDX Plgwood nailed at C o.c. in field and edges with 10d ring shank galvanized nails into truss webbing. NOW 10 1 1=0 I a-- 5/8" thick x 8"w cut Fffib 61-, L� I coral finished stucco bands a 64howl, 5/8" thick light textured Finish Columns with stucco on t9PIcal concrete 5/8" thick cut coral block construction frnished stucco bands FRONT ELE\/ATION CXL" #10/10 WWM on 6 all Via clean compacted termite treate� union over fill Interior Non -Bearing Partition Braden It Braden AIA, FA Wonne Building Corp. Architects - Planners 41-1 B S.E. Coconut Avenue THE STERLING Tel : (112) 281-8258 Fax E-mail: : (112) 281-8283 bradenaia0comcast.net Spanish Lakes Stuart. FL 14994 UAAr_0e)e)n`I St. Lucie Countg Florida SCALE: 1/4" = 1'-0' ALL CONTRACTOR WARRANTIES BEGIN WHEN THE CLOSING OCCURS BETWEEN THE BUYER AND WYNNE BUILDING CORP AND WILL CONTINUE FOR ONE YEAR FROM THAT DATE PERMITTING INFORMATION (FORM 100) Florida Buildin Bulldln% 9 Code Residential; (Pth Edition and ASCE 1-10 for Wind Loading Mean Design is: Enclowd Risk Categorg: 11 Wind Velocitg: 145 mph ultimate ocif Height.jr- " Roof Pitch. 4:12 .g Internal Pressure c;ourficient: tO.18 Subjectabilitg to damage from: Weathering: Negligible Termites. Verij Hall Width of Roof End Zone- 3'-4" Wind Speed: IQ mph ultimate Wind Exposure Classification: C 1 4pt Iwo: Adjt,stment factor for Exposure Height. 1.21 x 0.6 = 0.-1 ASO denn 'As 1"W1117N Load Combination: ASCE "I Section 2.4 DL+LL; DL+0AIlI' ; O.LDL+I L Components t Cladding Wind Pressure (NET) Roof Zone: 1. +20.4/-32.6 Pat Roof Zone: 2. +20.1./-51.0 Pat Roof Zone. 3. +20.4/-84.0 Pat Components i Cladding Wall End Zone Width. 'ft4 " Components t Cladding Wind Pressure (NET) ta I one. 4.+35.8/-38.1 PSI Wall Zone. 5.+35.8/-4j.s pet Components t Cladding Wind Pressure (NET) an Garage Door- +II Pat Shear Walls Considered for Structure? yes Continuous Load Path Provided7yes Are Components an Cladding 04-575 Provided?Yes Minimum Soil Searing Pressure..2,500pea, Presumptive: X Bg Test:-pv Thfa Building Shall Have thilIfr-ollowing, APPROVED SHUTTER& A IMPACT GLASICII, NEITHER: ROOF LIVE LOAD. 31 Pat ROOF OF -AD LOAD: 10 Pat ,FLOOR LIVE LOAD:_15- Pat FLOOR DEAD LOAD:_L0_ Pat JOB ADDRESS: 9\ QA-( MODEL: Date Drawn Revisions 3-28-18 RE Drawn bg- PORCH LEFT C.C.U. Checked bU. I ED. R. B. = Roof Zone I Walls Zone 4 = Roof Zone 2 Walls, Zone 5 END ZONE = Corner Zones Roof Zone 3 Sheet I Comm # OF 5 FLOOR FLAN CRASH FOST DETAIL TYPICAL NOTES: SCALE 114" F-0" N.T.S. 1. Contractor to verifg ALL notes and dimensions prior to S4" high bg I" diameter steel crash at. Floor 11 proceeding with work. Flange with 3/8" bolts 2. Contractor to STRICTLY enforce ALL OSHA Requirements. exgunsion into $a (S/8"t 50 kal steel plate) 3. ALL Lumber to be used as Beam, Rafters, etc... to have a minimum 1,400 fiber stress. 4. No dissimilar metals to touch. 2�2" 2 �2' 5. ALL Concrete used for slabs shall be min. 2,500 FBI concrete. �2" ALL Concrete used for vertical filled cells, cont. tie beams etc.. to 0 shall be 3,000 P.S.I. concrete and/or 4,000 F.S.I. grout mix 4. Drgwall at ceilings shall be leveled and attached to bottom chord of trusses with screws per FBC R102.3.5. 10 0 1. ALL wood in contact with concrete shall be pressure treated. r 8. ALL wall dimensions are nominal and not finished wall or stud dimensions. 9. ALL plumbing fixtures to be low flow. 10. Contractor to Provide Drain at water heater in accordance with the current edition of the Florida Plumbing Code. 11. Contractor to Provide a 2'-8" wide door at one bathroom for handicap accessibilitg requirements. 12. Lowest finished floor to be set bg Governing Building Department 5urvegor to set in field. 13. Separation between residence and garage shall be per FBC R302.6 1-4. Door between garage and residence shall be 1-3/4"t 20 min. rated door (�� = Water Heater 15. Wall and Ceiling shall have a flame -spread classification of not greater than 200 Der FBC R302.9.1 16. Wall and ceiling finishes shall have a smoke -developed index of not greater than -450 per FBC R3012.9.2 11. All exposed attic insulation materials installed on attic floors shall have a critical radiant I" 4" P.4. Buck nailed to Masomrq Beam flux not less than 0.12 watt per square centimeter. Exposed foam plastic insulation x block with case hardened nails materials exposed on the underside of the roof deck or on the attic walls shall compIg prior to do r attach em 18. with F.B.C. R314 - see permit info box of code edition G psum board material shall conform to ASTM C31., C19, C415, C614, C(.30, C931 N�O, 7 . . . . . . C1002, C104-1,C:11-1-1, C1118, C12-18, C1395, of C1396 and shall be installed LI accordino to the followinq: (FBC R DrUwall Thickness Location Orientation Framing ember �pacing Max. spacing of fasteners Nail sizing options for installation a drqwall into maximum wood framing members crews 20 x min. t tickness Ceiling Perpendicular 240 11. 124 13ga 1 3/8- long with 19/44' head OR 0.098m diameter x 1 1/4" long annular -ringed or Sd cooler mail Y2 OR Walls Either 161. a. 14" 0.080" dia. x 1 5/8" long with Direction 15/44" head OR Glpsum board mail 0.086" dia. x slam with 9/32m head. 13ga I slam long with 19/44" head Ceiling Perpendicular 2.4n 11. 12# OR 0.098" diameter x 1 3/8' long annular -ringed or 6d cooler nail % OR Walls Either all 14M 2" dia. x 1 -1/8' long with Direction I/ head OR Gipsum board mail 0-0915- dia. x 1/8" with 19/44" head. AREA CALCULATIONS Living A/C 1,414 Front Porch 53 Rear Porch 1% Garage 321 sq. sq. sq. sq. ft. ft, ft. ft. Total Under Roof= 2,124 sq. ft, Total Cubic Ft = 11,192 2* VTR 21' VTR Master( Bath I r 2' Lay. 1 W.C. 2' VTR a. 2' Shop. a" Kit. Sunk Kitchen 2- W.C. Bath #2 Shop. .0. Nclo-sh To Septic c.o. FLUME31NG RISER 1 0 0 Install SGID thru buck into If block with 3/14" tap -con 0 0 1 1/2" penetration at 4" o-c- max. from each corner and 20." o.c. max thereafter at head per product approval I" x 4' F.T. Buck nailed to block with case hardened nails Head prior to door attachment Ln fixed door Use 3/14" tap -con with sliding door 1/2" penetration at 4" o.c. max. from each corner and 20" o.c. max Masomrg Wall thereafter at sill per product a 19. ALL ceramic tile surfaces installed shall conform to ASTM A108.1 thru A108.L, A108.1, A118.1, AIIII A134.1 and A13-1.1 20. Cement, fiber -cement or glass mat 2psum backers in accordance with ASTM C1288, C1325, OR CII-18 and installe I.A.W. manufacturers recommendations shall be used as backer for the wall tile in tub areas and wall panels in shower areas. 21. Insulation including facings such as retarders or vapor permeable members installed within floor-ce[ling assemblies, roof -ceiling assemblies, wall, crawl spaces and attics shall have a flame Spread index not to exceed 25 with an accomPanr� smoke developed index not to exceed -450 when tested in accordance wit STM E 84. Insulation shall compl� with F.B.C. II Gulf Coast Supplg and MFG 5v Crimp Metal roofin�eFl_ u#1,1451.12 24 ijia. Sv crimp metal roofing attached to plgwood ck a ng #9 X 1.5' woo screws with self sealing washer at 12" o.c. max spacing over ASTM 0 (tgpe 2) 30 lb felt underlagmerit installed with min. 4" side laps and 41, end laps fastened with corrosion resistant tin caps and with 1.25' ring shank nails laced 4' o.c. at all laps and two staggered . rows 12" o.c. in field. Attach r k to trusses using attachment detail on this sheet Simpson HETA 20 or equal hurricane anchor at each truss 12 With (10) Od x 1 1/2' nails PRE-E!NGINEERED TRUSSES 24" O.C.) sup opting Max. at 2.4"o.c. TYPICAL 16101ba. upUt (aiiiiap drawings bg manufacturer) Aluminum Drip X X X xl�( X XX XXXX2LI X X '\R-30 blown fiberiplass Edge t Fascia im bottom chord or trusses -1/2" drgwall with smooth finish N�_and 2" x 4" Sub -Fascia ---- Two rows of beem block filled with concrete (1) #5 bar cont. in each row. Substitute Ka9can lull o vent vinyl soffit installed recast lintel filled with concrete and (1) #5 gar cont. for bottom row over openings using 1/0' dra shank x T.5' lorig galv. mail& with 3/8' dia. head per approval - ment chart shoat #1 1/2' driwallnover I" x furrin PI strips a 14 o'c. with II -Poll -insulation on tgpical 8" Block walls 5/8" thick light textured All drgwall to be installed per FBC R102.3.1 stucco on tgpical concrete T and shall meet all pertaining ASTM candes. ba Mortar to be T .1111 T pr ortioned per FBC R4011 0"39 block construction wit IFIBC R401.2.1. and Mortar jont'sipshall comp It ---- Provide Dur-O-Rock at all wet areas (ex. showers, tube etc... #S bar vert- w/ R� 30" overlap ----Fill call with concrete and at each filled call -,_(I) #5 bar vart. (tilpical). Max. spacing shall not exceed 48" unless otherwise mated Wood see foundation plan notes for spacing at openings 4" concrete slab with fibermesh OR 411xv #10/10 WWM on L mil Visqueen over / clean compacted termite treated fill Grade 3: 14" x 14" ConCrete footim with (2) #5 bdrs cont. ang #5 TYFICAL SECTION transverse bars at 48' a.c. Scale : 1/2" = I'-0" Bat -tom' -Track ...... TUpical Flooring Sill Install 5GD thru buck into block with 3/16" tap -con with 1 1/2" penetration at 4" -ax. max. liding E) cor E) et call from each corner and 20-' o-c. max 4. M n r 11 111011 N 7 _C; thereafter at jambs per product approval Jamb UJIndow Schedule Mark t Size Rouqh Open. - Window Description PRESSURE ZONE 1. 4'-5ka"x 5'�3!`a" 54k8"X 43!/4" Single Hung ZONE 4 2. 4'-2�e"x 5'1-3 !4a" 15" X 43 �Jm Single Hung ZONE 4 3. 11 x S'-i2 i 1/2' , 21�2"x 38%" Single Hung ZONE 4 '4' 1'ii'-Sy.mx 'q'712Vm 1 5,4y."x 5q%" Single Hung ZONE 4 ALL 1 Windows to be aluminum windows w/ tint and mullions per elevations. ALL windows to withstand pressures in permit info box on sheet I ALL windows in bathrooms to be tempered Ali rough opening dimensions to be verified bg contractor ,�witfi manufac.tiurer s specs prior to construction Door Schedule lark Size Rough Opening Door Des ription PRESSURE ZONE A 9'-0" X T_ON X 84" Overhead Garage Door ZONE 4 B 3 1-00 X 41�4x 03/4 Fiberglass Panel - Inswing ZONE 4 C V-011 X 14# x-81 �2" Sliding Glass Door ZONE 4 21-04 X Solid Core - Wood L-Pamel -Bi-Fold Finished 24" x 81 �2" -D 2'-t.- X 4'1-8' Solid Core - Wood 4-Panel S`Om X C-8" Solid Core - Wood 4-Pariel - Bi-Fold G 2'-80 x C-8a x 1 N' Solid Core Wood. Steel, or Masoryte Door H 2'-S" X d.1-8n Solid Core - Wo - 4-Paimel 12�' 101-on 0 p�. P A All =71:i �LOJLOJ EGRESS L 12" x 12' Concrete column/ block filled with concrete and 12) #1 bars vert. tied into lintels above Covered Porch Provide screen infill below MASTER UUC BEDROOM jilg'-Om to cl':0" A�F,F. 00 LL-V U -r =.' - F = 9L 8'-0" Vaulted Ceiling Flat Ceiling GRE �T R 0 0 Jim C4 O_ -0. 231, H.B. 0) Vamitv to-ee- bo 2' x 4" knee -wall jila'-Ot to 9'-8" A.F.F� ;4) rr(T- J below counter top qv Vaulted Ceiling CL(:),,. FT [DINING :!J LIKEN a. 7. R 0 0 M CASINP F Ro7 iTsh-elf I Dim/ ATH LU Vanitg to be 34 �2' high /I S'- 0 3/,4 <ITCHE� Vemil Dr4er.. M throL h wall Q L 1-1 2" 7 (1h8-0. A.F.F. r­Flat Ceiling 101-51, 4'- 1 dr _1 - I--- CnLA1K53NNP p er a inets to L) extend over Ref. 10'-2" Q 2- filler-� In Ifti E BATH LEE Rod t Shelf 0 kF R-11 '�`Iat W.H. 0) A/C I Ballard E� I Ey�edtyeteail on this --iI -8 57 > L eNb� Provide auto F _ii' _x 14'- L!J closer Attic Ac"ces"s with I,& J :22" Flat Ceiling 150 Amp Met in e' Panel I Lip, SECOND GARAGE El' RGEN Y BEDROOM-, E RESS COD 0 JILi A.F,F. M Cil 3 Flat Ceiling r- ci 0, r- - - - - - - - - - - - - - - - - EGR Block wall in I "I" to be R E a strucT block (D C VERED 12- x 12- concrete coluitin block filled JJORCIH with concrete and (2) #1 bars vert. tied into lintels aboye /-A\ 2" E131 Ed 'y 3`5" 91-01, 31-51, � 2`8' 2'-811 S'-2- 61-4n >� 31. me 31, < > >� 51-411 e 341-OU J 2'-Iu X vi-an Solid Core - Wood - 4-Panel, Bi-Fold Install windows thru buck into block with 3/16" tap -con with I 112m penetration at 4' o.c. max, from each corner and 20.' o.c. max thereafter ats,dambs and 20" o.c. max. Exterior face at head and per product approval of wall --\ Buck to be I' x 4' PT 21-SR X Ll- an Solid Core - Wood - 4-Panel Bi-Fold L it, 111-411 X IV I an " I 131-FOLD ALL Exterior doors to Withstand pressures stated in permit info box on sheet 41 GARAGE DOOR SPECIFIED IN PRODUCT APPROVAL FORM AND SHALL in in C4 Attach buck to block wall with 1/4' dia. Elco conic screws with min. 1 1/4* penetration at 12" o.c. max and 4" max from each corner thru Exterior face 2" x 6" FT Buck of wall WITHSTAND THE PRESSURES STATED IN PERMIT INFO BOX ON SHEET #1 I"x4" P.T. Buck nailed to _���rlock INSTALL VULKEK BLOCK SEALANT All roucih otieninci dimensions to be verified bg contractor with case hardened nails Detdil at Windows prior to window attachment ON ALL JAMB, HEADER, AND SILL BLOCK PRIOR TO BUCK Detail at Door with manufacturer s specs prior to construction NTS Braden t Braden AIA, FA Wi4nne Building Corp. Date Drawn Revisions Architects 411 - Planners S.E. Coconut Avenue THE STERLING REAR 3-28-18 Drawn bg: Tel B : (112) 281-8258 PORCH C. C. U. Fax : (112) 281-8283 Stanish Lakes LEFT Checked bV: E mail: bradenaia9comcast.net S . Lucie Countg Florida Stuart- FL S499L UAAC000032 hD Qr_ 98 Wood screws thru jamb into buck at each hinge and 15' &c. max and prior to door attachment NTS Sheet 2. oF 5 OD IV - Comm # 341-01, - Z:) 1 771 U �� I U r7N /"� L_ IN �_/ I T__ *:?: I. ALL FOOTING ARE DESIGNED FOR A MINIMUM OF 2,500 PSF SOIL BEARING CAPACITY. IF ANY SUB -SOIL, MUCK OR NON -UNIFORM CONDITIONS EXIST, REPORT TO ARCHITECT AND OBTAIN PROPER ENGINEERING DATA FOR DESIGN. 2. ALL SLABS AND FOOTINGS TO BE A MINIMUM 2,500 PSI AT 28 DAYS ALL COLUMNS, FILLED CELLS, AND BEAMS SHALL BE MIN. 3000 PSI BE 3000 FBI OR 4,000 PSI GROUT MIX AT 28 DAYS 3. POISON SOIL AND COVER W/ 4 MIL. VISQUEEN WITHIN 24 HOURS. NO SOIL POISONING TO BE ACCOMPLISHED OUTSIDE OF FOUNDATION. 4 GROUND FLOOR SLAB TO BE A MINIMUM 4" THICK W1 4X4 10/10 WELDED WIRE MESH REINFORCING ON 4 MIL. POLYETHYLENE VAPOR BARRIER ON TERMITE TREATED, CLEAN MACHINE COMPACTED FILL (MINIMUM 95% DENSITY). LAP POLYETHYLENE 12" MINIMUM. FIBERMESH MIX MAY BE SUBSTITUTED FOR WELDED WIRE MESH. 5- LOT TO BE CLEARED OF ALL SMALL PLANT GROWTH AND DEBRIS BEFORE FILL 15 BROUGHT IN. FILL MATERIAL SHALL CONSIST OF CLEAN GRANULAR SAND CONTAINING LESS THAN 10% MATERIAL PASSING THE US STANDARD NO. 200 MESH SIEVE, PLACE STRUCTURAL FILL IN LOOSE LAYERS OF 12" IN THICKNESS AND COMPACT EACH LIFT TO AT LEAST 95% OF ITS MODIFIED DRY PROCTOR VALUE. 6- GENERAL CONTRACTOR TO VERIFY ALL EXISTING CONDITIONS AND DIMENSIONS. BRING ANY DISCREPANCIES OR OMISSIONS TO THE ATTENTION OF THE ARCHITECT. '1- GARAGE FLOORS TO BE SMOOTH TROWEL FINISH (SLOPPED PER FOUNDATION PLAN). PROVIDE 1-1/2" RECESS FOR OVERHEAD DOOR FOUNDATION FLAN 8. SLOPE ALL PORCH SLABS, COVERED WALK, ETC. AWAY FROM HOUSE TO DRAINS (IF PROVIDED) PER PLANS 9. DESIGN LOADS ARE AS FOLLOWS: ROOF (DL+LL) = 41 PSF WIND VELOCITY = PER PERMIT INFO BOX ON SHEET #1 EXPOSURE =10C11 10. ALL REINFORCING STEEL SHALL BE GRADE LO, MEETING ASTM A-14. A-35 SPECIFICATIONS. ALL ANCHOR TO BE A - 301 STEEL. 11. ALL DOWELS, SLEEVES, CONDUITS, INSERTS, BLOCKOUTS, ANCHOR BOLTS AND FRAMES SHALL BE IN PLACE PRIOR TO POURING CONCRETE. FOR OPENINGS AND SPECIALi FEATURES OMITTED ON THESE PLANS, SEE ARCHITECTURAL OR MECHANICAL PLANS WHERE APPLICABLE. 12. MINIMUM CONCRETE PROTECTION FOR REINFORCING BARS: FOOTING: 3" BEAMS: 1-1/2" 13. LAP ALL REINFORCING STEEL A MINIMUM OF 48 BAR DIAMETERS. 14. USE STRUCTURAL GRADE W0100 WITH A MINIMUM Fb OF 1400 PSI I IS. ALL STANDARD LUMBER SHALL BE SYP WITH A MINIMUM Fb OF 1000 PSI OF NO.2 SOUTHERN FINE, UNLESS NOTED OTHERWISE. 16. ALL LUMBER IN CONTACT WITH ANY CONCRETE OR MASONRY SHALL BE PRESSURE TREATED. FASTENERS TO HAVE MIN. G185 RATING. 1. Ang changes to plans must be submitted to the architect for approval before proceeding with construction. 2. Contractor shall be responsible for verification of all notation and dimensions before starting corstruction. 3. Soil conditions assumed to be 2500 psf. Should ang other conditions be encountered, the architect shall be notified in Writing for revision 4. Verifg all recess thickness at showers, tile, etc.... S. Contractor to provide filled cell With concrete and 1 1*5 bar vert. at 48" O.C. max. Provide (1) filled cell on each side of openings 11to S'-11" wide. Provide (2) filled cells on each side of openings from �' _ t to 9'-11" and Provide (3) filled cells on each side of openings from 10'-0" and up Contractor to see plans for ang other condition used. Foundation walls shall have filled cells at 24" o.c. unless otherwise noted (see section) 4. Contractor to provide for Form Board Surveg — Form Board Surveg to be provided to Truss Compang prior to truss construction 1. Contractor to provide for soil test prior to construction and provide a copy of soil test to architect for review prior to construction 8. ALL Reinforcing steel shall be grade 40, meeting ASTM A-1� and A-36 specifications. ALL Anchors to be A-301 steel. 9. Provide a minimum of 3" concrete protection at footings and 1-1/211 concrete protection at beams for ALL reinforcing bars. #5 bar Vert. wl 30" overlap — at each filled call 4" concrete riab with fibermesh OR 411x6" #10/10 WWM on 10 mil Visqueen over clean compacted termite treated fill Grade\ J 7, 1.4% x Wd concrete monolithic footina with (2) #5 bars cant. U 1-4 " TYPICAL FOOTING DETAIL SCALE 1/2" = 1'-0" 40, concrete slab with fibermesh OR 4 llx4" #10/10 WWM on io mii Visqueen over clean compacted termite treated fill US bar cant. Step per foundation plan C14 lo" (2) 45 bars cant. bottom steel DETAIL AT GARAGE STEFDOWN _J SCALE 1/21, = I,_O;1 12' x 12' concrete column block filled with concrete and (2) 91 bars Vert. tied into lintel& above T o .p of footer 14 below finished ]car 94 30" COLUMN FOO 'Verifg house slab height in field 30"x30"Ag" concrete T_­--column footing with (4) US bars each wag DETAIL SCALE 1/2" ;r Thicken edge to 8"x8" with concrete and one US bar continuous GRADE,, SCALE: 1/4" = 1'-0" Termite Protection for New Construction. Soil treatment used for subterranean termite prevention inside the foundation perimeter shall be done after all excavation, backfilling and compaction is complete. If soil area is disturbed after initial chemical soil treatmen area shalli,be re —treated with a chemical soil treatment including spaces boxed or framed. Treatment must be in accordance With the rules and laws established bg the Florida Department of Agriculture and consumer services. Protective sleeves around metallic pipin% penetrating concrete slab on grade floors shall not e of cellulose containing materials and shall receive application of termicide in annular space between sleeve and pipe. 4" concrete slab with fibermesh OR 4"A." 410/10 WWM on 10 mil Visqueen over clean compacted termite treated fill 7 1-:4 PORCH SLAB EIDGE DETAIL SCALE 1/211 = 11-01, #5 bar Vert. w/ 30" overlap at each filled cell Adjust curb het ht based on gar. Mollolr slope. 45 bar in curb Grade 5FE TYPICAL SECTIONS 4" concrete slab with fibarmeah OR 0XV #10/10 WWM an 10 mil Vi4queen over clear compacted termite treated fill 14% x 1-4"d concrete monolithic 'footine with (2) #5 �bars cant. ARAGE CURB DETAIL SCALE 1/2" = �11-01, 2" x 6" PT wood se6red wt 3/8'dia. x 6' anchor bolt V118" O.C. overhead door track secutied to wood jamb per manufacturer's product approval Garage Door Jamb Detail GARAGE DOOR TO WITHSTAND PRESSURES STATED NTS IN PERMIT INFO BOX ON SHEET 41. SEE PRODUCT APPROVAL FORM FOR MANUFACTURER MAKE AND MODEL. Filled Cell Masonrg Column With One #S From Footing To Tie Beam Conc. Fill To Be 3000 PSI See Floor Plan For Location sin(gle Filled Cell Column NTS Filled Cell Masonrg Column With One #6 From Footing To Beam Each. Conc. Fill To Be 3000 PSI See Floor Plan For Location Double Filled Cell Column- NTS Braden it Braden AIA, FA Architects — Planners 41-1 S.E. Coconut Avenue Tel (112) 281-8268 Fax (112) 281-8283 0B E mail: bradenaia9comcast.net Stuart. FIL 34994 UAAC000032 Ln 1.41-01, 1_3T 10#. PATIO d) ti 1:2 " L-JI I IL-JlLJ 01 1 1 LJ_ I — — — — — — ILI — — — — — — — — - _ILQJlU Rear Patio/Slab to be poured separate lu L from the house slab. 1L 24 24"w x 1.4"d x 21 Thicken footing t under filled cells I.- J under girder bearing. FiGil I I I 1 19 1 1 1-71m— 1 1 1 1 1 IE LIL — — — — — — — — — — — — — — — - I Uri Mear ffatio/b'Ah to be flush with bottom or sliding door recess. Slope 1/2" D 0 H.B_ Vanitg to be 1,6`­�4 �2 high 4" concrete slab with fibermesh OR ,"xL" 1110/10 WWII on I m,1 V,squeen over clean compacted termite treated fill ,4�—O" 0 F — — — — — — — — 4'0 Steel Ballard filled wl Concrete 0 LU 7w� > FS ZJ 0 L to 4) 4� 0-90 E 0 q) E t! E L t! A a Q) .1 1 ,nv-/// I _41 a 0 q) 0, W =x 'a -NIJ V Recess for V _d�_ar_ag;_ 5-oo—r —EICDI FIT - - - - - - - - - 8 L 12" x 12" concrete column block fillet with concrete and (2) 41 bars Vert. ti < into lintels above ->I< Mile Wanne Budding Corp. THE STERLING Sparush Lakes St. Lucie Countg Florida REAR PORCH LEFT V a"- in I za ;D V, FOOTING SCHEDULE Mark Size Description 1 14ffiw X HMD MONOLITHIC FOOTING WITH 2 #5 BARS CONTINUOUS 120W X 12"D MONOLITHIC FOOTING WITH (2) #5 BARS CONTINUOUS 30a x 30" x It aD COLUMN FOOTING WITH (4) #5 BARS EACH WAY 8"W X 8"D THICKEN SLAB EDGE WITH 1 #5 BAR CONTINUOUS Will With x 14"D Curb at Garage MONOLITHIC FOOTING WITH 2 #5 BARS CONTINUOUS - CURB 9 0'-0' Date Drawn Revisions Sheet Comm 3-28-18 Drawn bg: C.C.U. B Checked bg. 0. R. E5. OF 5 ROOF SHEETING ATTACHMENT DETAIL 1. Minimum Nail Size = Sd ring shank (min. 2.5" long) 2, Minimum Screw Size = US x 2" 3. Minimum Sheathing Thickness 19/32" COX Plawood 4. Use nails or screws basqd on presspre for rooF stated in permit info box on these plans for zone 3 K Area Edge Field Fastener Max. Pressure Zone I L 11 L it — Sd ring shank 45 psf Zone 2 It 4 If 8d ring shank- 16 pef ///Zone 3 -.4 44`1 4 U 8d ring shank 84 psf Zone 3a L it in If I #8 wood screw I 112.5 psf Use nails or screws based on gresiure for rgof stated in permit info box on these p ns or zone Concrete / Lintel Column Verifg with Plan 12 If x 12 " ,lumn Block #1 Rebar Rebar -48 Bar Dia. Min. Overlap to Lintel Attachmert NTS Provide US bars with min. 48 bar Provide #5 bar set in pro -cast diameters overlap into beam. Tic filled call steel into continuous lintel into boom where length of beam block steel. the opening calls for it. Provide Cast -Crete SUB-OB/OT precast lintel act in mortar Min. 8" Bearing it i, Provide PT Buck Poured rilied Coll attached Perl.jdamb details into III call 4* Pro -cast Silt% Provide #5 bars with min. 48 bar diameter& overlap in filled call. Tie billed call steel into continuous rooter steel. Concrete rooting ...0 (see footer schedule sizes) DETAIL AT WINDOW OPENING IN CBS WALL Scale: 1/2" = 1'-0" i,,SINGLE PLY REAR GIRDER TRUSS Nail 2" x 4" blockipp to vert. log of true& with 10d x 1.9 nails at 4' cf.c. Install Simpson MOT into wall using 5/8" dia. threaded rod *at min. 12" s, into wet beam and (22) 10d nails into truss TRUSS BLOCKING DETAIL AT GIRDER STRAPPING AT CENTER BEARING POINT 1/8" thick light textured stucco installed per ASTM C 924 over AST11 D tgpe 2 pa er backed wire lath mailed to substrate through one ?a of ASTM D T no Substrate 3�pe 2 felt paper using Scl to be 19/ CD X Plilwood nailed at 6" o.c. in field and edges with 10d ring shank mails into studs. Gulf Coast Suppli; and MFG Sy Crimp Metal roofing FL #114SI.12 2!ja.,Sv crimp metal roofing attached to plilwood deck using #9 x 1.5" w a rews wit , h self sealing washer at 12" o.c. max spacing over ASTM D (tgpe 2) 50 lb felt underiagment installed with min. 4 side laps and 4" end laps fastened with corrosion resistant tin caps and with 1.25" ring shank nails ?aced 6" o.c. at all laps and two sta gored . rows 12" o.c. in field. Attach eck att artai to trusses using achment d , on this sheet Additional Precast Lintel IfBif #5 bar* -ze Lintel Bar Clear "A" Lengthill-ength Span Bars Bars ai CLIKAR 2,43 none 2'-10" 2` 8 31-41, 31-41, 2'-2" 2,#3 none Additional 2.43 none #5 bar& CLEAR -,4. V-2- 2.43 none no Rom or W lock Above 0 2,43 none -4" 2,44 none Is Precast Lintel U. mome Addit I IL ---- it #5 b4 2.31:5 none NOTES: OPM-115AT SPIL-IB/2T T-O- 2,46 none 1. min. coverage of steel-l's" 2. min. bearing required 0 fra. ond=8" ALL reinforcing steel is grade 40, 3. standard for rainf, ateel=ASTM A415 TYPICAL LINTEL SECTION ( PRECAST CONCRETE ) Mari L22 LSI L45 LBO 1­60 Leo 1.40 L40 Ll LIO( L12C L12C LI4C 1-140 L160 L F Simpson HETA 20 or equal lur�lcanfs anchor at eac; truss with (10) 10d x 1 1/2' made - 24" o.c.) supporting Max. 1810lbs. uplift Aluminum Drip Edge 4 Fascia 12" 2" x 4" Sub-Fascil Kagcon full a vent viNI sorlit installed using 1/8' dia shank x 1.5' long gaiv. roaring nails with 3/8' dia. head per product approval - not chart shoot 91 12" x 12' concrete column block Idled with concrete and (2) #71 bars vert. tisj-� into ]Intel& above thicken edge to 8"A' with concrete and one #5 bar continuous BEYOND T?p of footer — 16 below finished floor 12 F Aluminum Drip - Edge t Fascia Flash and Counter flash Na" ledger to _go b [a and true& with 12) IOd I at each web n4� an 3/8' hi-mb lath ntal and vertical sood r sta"os to 'rovids 4. penetration into is mg,mrid 3/40 Penetration o members 5/8" thick light textured stucco on tlipical concrete block construction Varies - see plan #5 bar vert. wl 30" overlap at each filled call Rear Patio/Slab to be flush with bottom of sliding door recess. Stop per foundation plan - el Slope per foundation plan Wood Brace Gable end with 2* x 4' SYP #2 8ft back mailed to bottom of top chords using (2) 10d nails at each trust PRE-ENGINEERED WOOD TRUSSES >. 9 24"o.c. TYPICAL ( shop drawings bg manufacturer LU C4 < W td E Cl) C4 C4 L1J E:al( Brace Gable and with 2' x +' 5YP #2 min. 8ft back nailed to bottom — of top chords using (2) 10d mails at each truss IMAM 04 ,R-30 blown fiberglass < in bottom chord of trusses o 0 in -1/2' drilwall unth smooth finish Two rows of beam block filled with concrete X (1) #6 bar cont. in each row. Substitute -and recast lintel filled with concrete and (1) #5 or cont. for bottom row over openings 1/2" drgwall over I" x furrin Pl-foil at 14" o.c. with R-4.1 _strips insulation on tI Off Block walls All drUwall to be installed per FBC R102.3.1 and shall meet all pertaining ASTM codes. Mortar to be T9pe "IM" onl,� proportioned Der FBC RtO1.1 and Mortar joints shall comDg with PBC R401.2.1. Provide Dur-O-Rock at all wet areas fox. showers. tube etc... Fill call with concrete and (1) #5 bar vart. ftgpical). RCOF -Max acin shall not exceed Strap truss to wall using Simpson MGT with Simpson HETA 20 w into beam (22) 10d either wat nails into act or in epoxv with truss. Add blocking to of 24 o.c.) supporting Max. truss leg per detail on this sheet C-H—E T A 2 0 1810 lbs. uplift MIEW12 MEN lilt =AMI MIMI FAA I GIW noz IVA ®R NOW I MAN AN NEWS 'AV FF All WAS 4 A1 FARA Coast Suoi;flu--and MFG SY Crimp Metal ro hnQw%.jWJIr4-1N1— --Gulf Wo Wg in screws Solt Seallng washer at 12" o.c. ax cl over ASTM 0 x ; n (tUpe 2) 30 lb felt underlagment installed with min. sidegiflaps and V end 4J lao-fastened with c,orrosion resistant tin caos an w 1.25 rinq shank nails a, off ape ana MvRojeaiou ME J Teacck"tobtru'u-'as using attachment detai an this shea IW x �SV A ttic Access FSLOPE RAMAN with tight rim I mom FLAN I � 0 48" unless otherwise noted see foundation plan motes for - OVERHANGS AT 1'-0" UNLESS OTHERWISE NOTED ON THIS SHEET spacing at openings 4" concrete slab with fibermesh OR - ROOF PITCH AT 4:12 UNLESS OTHERWISE NOTED ON THIS SHEET Vx4" #10/10 WWM on 1. ind Visqueen over - TRUSS SHOP DRAWINGS TO BE PROVIDED BY MANUFACTURER Z clean compacted termite treated fill — ANY CHANGES TO THIS PLAN SHALL BE SUBMITTED TO THE biqlmm"lll son so 11410 -- Tubicdl Section dt Front Forch Scale , 1/2" = 1'-0" Braden t Braden AIA, FA Architects - Planners -41"T S.E. Coconut Avenue Tel : (112) 281-8258 Pax : (112) 281-8283 E-mail: brad enad a9 comic ast.net LU :3 UJ E W z" LLI U-n LLI 0) Z F- LLJ I < LU in F- LU ARC I CT FOR At�t-KUV/-\L- IN UJKI I ING PRIOR I V K INL; LUNO I KU�-, IVI - ALL TRUSS TO TRUSS CONNECTIONS BY TRUSS MANUFACTURER - ARCHITECT TO REVIEW TRUSS SHOP DRAWINGS PRIOR TO CONSTRUCTION FOR LAYOUT AND UPLIFT VERIFICATION - CONTRACTOR TO PROVIDE FOR FORM BOARD SURVEY AND TO PROVIDE FORM BOARD SURVEY TO TRUSS COMPANY PRIOR TO TRUSS CONSTRUCTION WQnne Building Corp. Date Drawn Revisions Sheet B-28-18 REAR Orawn bq: THE STERLING PORCH C.C.U. W4 Stanish Lakes LEFT Checked bU. S . Lucie Countg Florida 0. R. S. OF 5 Comm 0 - I pt. PANEL "A" Pales SR Load Wire Description circS circ# Description Wire Load BR Pelva 2 40 1.0 kw #9 A/C camp 1 2 AHU #10 3.5 kv 30 3 4 2 30 4.5 kw #10 40 gal. we 14TR 6 A Range $4 12.0 kw so 2 1 20 1.8 kw #12 Pump 41 10 DrVer Sic 5.0 ke 30 2d I 1 11 12 I . 1 20 1.5 kw $12 13 14 Dishwasher #12 L2 kw 20 1 1 20 1.5 ke #12 Microwave is It, Refrigerator #12 1.2 kw 20 1 1 20 1.6 kw #12 Kitchen S.A.C. 11 Is Racept& #12 - 20 1 1 20 1.5 kw #12 Kitchen S.A.C. 19 20 Racepts #12 - 20 1 1 120 1.2 Its 212 Clothes Washer 21 22 RecoPts #12 - 20 1 1 20 10.81 kw $12 Garage Door Opener 23 24 1 Recepts 412 - 20 1 1 20 1.4 kis #12 25 26 Recept* 912 - 20 1 1 20 1-42 kw #12 21 28 RecePts #12 - 20 1 1 20 #12 General Lighting 21 30 Recepts #12 - 20 1 - 1 20 #12 General Lighting 31 32 Recepts 412 - 20 1 1 - 1 20 #12 General Lighting 33 34 Exterior GFC1 #12 - 20 1 - 1 120 1 #12 1 General Lighting 1 35 1 31 1 Bathroom GF1 912 - 20 1 - 1 20 *2 Smoke Detectors 31 1 38 General Lighting #12 20 1 20 #12 Bathroom G151 9 40 Genera Lighting $12 - 20 1 sbare '41 42 sbare PANEL "A" LOAD CALCULATION SHEET Load Description oty. Watts Total(Watts) General. ........ .......... .. ...... .Fqfr!gqratPr ................................................... Mi.c.rcwaye .... ........... ........... I ..................... Dish.. Washo.r... ...... ................................. .CI.otheP..Dryqr ................................... .Pater-Hapte! ..... I ...... ........ ........................... Water Pump ....... I ...................................... pprpga� 1135 a 51205 2 1,500 3.000 1 12,000 12000 1 1�200 1,200 1 1.500 1,500 1 1,200 1.200 5,000 4,500 1 1,200 1 5,000 1 14,500 I 1 1.800 800 --L--- 810 1 810 Total Watts 31.415 First 10000 Watts 0100% 1 10,000 10.000 Remainder 21,1415 910% 1 0 10,961, Electric Heat or A/C 10,000 945% 1 10,000 10,000 Calculated Load Watts 30.9LL Voltage 240 -T -.0i Calculated Wattage Divided bi; Voltage = Total Amps 29 Panel Size Required 150 Amps 'rElectricdl S�mbol Legend S Single Pole Switch Recessed Can Light ,% Double Pole Switch Eileball Recessed J. Push Button Switch Exhaust Fan Duplex Outlet Coiling Mounted Light Special Receptacle 0- , Wall Mounted Light Wa int= ground fault circuit PC Light with Full Chain (attic) Floor Duplex Outlet @ Computer Connection Jack Carbon Monoxide Detector 4& Flood Light (D Thermostat c:-�-i Electrical Panel 19 , Central Vac [E� Electrical Meter @ Smoke Detector Calling tan R Television Jack Telephone Jack ACoisc A/C 0 Iscorinect CEM I x 4 Florescent Light CED 2 x 4 Florescent Light MSpeaker Hook -Up El Intercom Vgn1-thLLL --- Soffit 149 CFM IOXIOX6 1441 Clsm IOx1OX4 12xI2xIO B/A ATH Meter 150 Amp A k Panel 9 CFM Covered Porch 12x12xIO B/A 9-1 C niter Registers 4\ 1 20 M coiling tan 209 CFM "N [O)d IOx1Ox'T N 1210 L- - - - - - r- - K, I x Attic Access T math light_ 1 4 L- - - - ii- - I FL i :'- - I GARAGE r------------- --- i JUNCTION BOX TO SUPPORT A FAN THERMOSTAT LOCATION �IECH,4`NIC,4L L,4`rl UT B/A BALANCED AIR SCALE: 1/4" 1`01' Electric Notes: 1. Use copper wire onIU, no aluminum. 11, It is not the intent of these plans to show everg minor det if 2. Provide and wire all required smoke detectors. of construction. The contractor shall furnish and install 3. Contractor to verifg location of electrical all items for a complete electrical sgstem and provide all service and provider. the requirements necessarg for the equipment to be placed in -4. ALL �addle fans shall be on a rheostat. proper working order, S. ALL ath and kitchen receptacles to be GFI rotected. 18. All work shall be done in accordance With the N.E.C. and 4. ALL exterior outlets to be WP/GF] protectel' shall complg with all local codes and ordinances, and shall I Recessed cans to be installed per NFPA requirements. meet all standard requirements of the local electric utilitg S. AFCl receptacles are required in all rooms except and telephone compang. Kitchen, Bathrooms, and Garage. 9. A/C Return Air Balance Must complg w/ FBC RM1402 19. The electrical sgstem shall be completelg and effectivel 10. A/C Refri arant lines that are run thru slabs must be sleeved in AVC grounded as required bg the latest edition of the N.E. 11. ALL A/C Equipment shall compIg with energg calculation 20. All material shall be new and shall bear underwriters' 12. All work shall be performed bg a licensed electrical labels where applicable. contractor, the completed s�stem shall be fullU operative. 13. Contractor shall pag for all ees, permits, testin and 21. All equipment and panel sizes shall be verified before inspections including blower testing wher 91 ordering. The contractor shall provide circuit routings to 14. All work shall be coordinated with other tra8es to avoid suit the job conditions. interference with the progress of construction. 15. All required insurance shall be provided for protection :22. Furnish and install all fixtures as called for on the plans against the public liabilitg and propertg damage for the or as selected bg others. duration of the work. 16. Contractor shall uarantee all materials and workmanship 23. All racewags and pipes placed in or through ang concrete free of defects ?or a period of not less than two gears from slab shall be spaced a minimum of three diameters of the the date of acceptance or certificate of occupanc4, or one largest conduit or pipe from ang other service. gear from closing sale of house. Correction of defects shall be completed without additional 2-4. All exposed wire below 9'-l" shall be installed in metal EMT charge and shall include replacements or repair of ang conduit. other phase of installation that mag have been damaged. 25. Orger Vents to be installed per FBC RMIS02 2Clx2O N-vr/ r 70 1 P,1 1 lCell COVERED PORCH DINING ROOM Is CFM ;8x4x14 ATH 1.4t clom IOx&xL SECOND BEDROOM 1\ 12x12x8 �� 15/A disc. I ]so #2/0 Aluminum food MACITC 1%" Conduit I PANEL 2" PVC ( 2" rigid service l3PL 5ar; U copggawire I F to 5 comt. 0 r in Web ELECTRICAL RISER - Contractor shall use AL-CU Landing lugs. NTS - Contractor shall torque lugs I.A.W. manufacturers recommendations which shall be verified prior to construction r H-" , ant thru -14�01ff-1 t- - - - - Exhaust Duct Thru Soffit 4" Exhaust Duct Thru Wall W.P. G Install ou'et under disr. not shown ��orl claritg , FD Meter ELECTRIC;i4L Braden It Braden AIA, FA Architects - Planners ,41-1 S.E. Coconut Avenue Tel : (112) 281-8258 Pax : (112) 281-8283 E mail: bradenaia9comcast.net F L 4 N SCALE: 1/4" 1'-011 Post Light with"-� Attic Ventinci Calculations FBC 2309.1 Total Attic Space = 2124 sq. ft. Venting RdtlO 1/150 = 14.1� sq. ft. required Provide A Continuous Vented Soff it WQnne Building Corp. THE STERLING Spanish Lakes St. Lucia Countg Florida Date Drawn Revisions 3-28-18 REAR Drawn bg: PORCH LEFT C.C:.U. Checked bg: ID. R. B. Photo call 1 1, H.B. Exhaust Duct Thru Soffit E Wire For Front Post Light Sheet Comm # , F - 1 ]�-300 B OF 5 A=LIFE SAFETY WARNING This symbol identifies Life Safety Warnings that should be read given special attention by all persons installing trusses. 330,' Span or less 30' to 60' Span 60 Spreader Bar 0 degrees o r less 112 4— 0 If— Approx 2/3 to_. ij Jne span cpprox. 1/2 of span REFER TO BCSI REFER TO BCSI ­5 be set t�s �Iy if ��alc �sld. Tr.ss must be set this way if crone used. I'll , nn ...,pl,, �, lr,,� ,y �t �t,h. This is an example, truss may not match. � I �p ... t.� "t, t"'�"' t�'s way� �nsist crone operator sets truss this way. MULTIPLE PLY TRUSSES MUST BE =ASTENED TOGETHER PER ENGINEERING BEFORE SETTING. REFER TO ENGINEERING DRAWING TO DETERMINE A IF MULTIPLE PLY. A'I For Truss to Truss Carrying Girder Connections see hanger/connector TNaffs must ]be as shown. Guide tabs oi wn schedule in engineering Dome angle nails. package. Carried Truss SEAT PLATES BY CHAMBERS upset�1/4" heel=3 15/16" PLUMB CUT END 2 x 4 Top Chord WALL HEIGHT 8' END DETAIL: TYPICAL VAULT ul l 15/16" PLUMB CUT END 2 x 4 Top Chord WALL HEIGHT 8' TYPICAL END DETAIL INDICATES LOAD BEARING REQUIRED BY TRUSSES SUPPLIED BY BUILDER AT A HEIGHT OF ll ABOVE FINISHED FLOOR MODEL SHO LID BE SHIPPED AND SUCCESSFULLY SET BEFORE ANY MORE TRUSSES ARE BUILT FOR THAT MOI)EL. AKKANUtz VVII I H CRANE OPERATOR IN ADVANCE FOR A SPREADER BAR OF 18'. 24'IN LENGTH -I Do not stand on trusses until they are braced per BCSI & properly nailed to straps & hangers 17 7 7 7 7 1 I 5PAGIN G��, NOTE ALL TRU55ES ARE TO BE 5ET AT 2'-0: ON CENTER EXCEPT A5 NOTED UNLESS NOTED ELSEWHERE ON THIS LAYOUT, THESE TRUSSES ARE NOT DESIGNED FOR AIR HANDLERS IN THE ROOF OR FOR ANY OTHER AIC REQUIREMENTS. THIS MAY BE IN CONFLICT WITH BUILDING CODE AND AtC DESIGN REQUIREMENTS. CONSULT WITH BUILDING DEPARTMENT AND AIC CONTRACTOR. know an, MIA q 11 2? 11 W, 11 -, ll:; 11 '� All load bearling walls, headers, beams & lintels must be in place at indicated height before trusses A are installed. A J2 34 J6 DON'T LIFT TRUSSES WITH SPANS LONGER THAN 317 BY THE PEAK CONSULT BCSI t*r� INVERTED -Ar WEBS AT CENTER Wff B.C. VANNEL LOAD W/ (2) 500 POINT LOADS PER TRUSS FOR AM 6. 1 PAP 'AP FA V ATA ATA ATA ATA ATA ATA ATA A`TB L; A -F1 A5 A5 A5 I l I 111"Actut;A-1111101111 AGREEMENT- TI==CAIQW=8TMTEcuKMTM Mar logall dooc*don oftlie pripartirutore to &RMUMM Will be made In oft diagran 11111,014 bar =&= fine bow vartialt byfaft A Urivis Vxfttffl nodow k b(doillmiryttle ==%ilm Within ten (10) Mormon get no = we be noweL.1, #0 Much wrow n= ow tomirepolm req*,K arlo autioutb* cow In "Noli by 7PI & wrok do"- chambers Thin Irso ara "lle ou"Wrov fin lob.!lte.a-Mabla for El ORDER So kh or Ill WIN of blIdellinityllbuyer ..Ilemed Morgan; orPMynMolnt=P"CW*"` TOM I b, tmm. "WIS. I -in Ili Par morim sqvjm &.80rature or Inhish wWwthan, w= oweemwd to sif 9, In consideration of Cheipbom Tn" ==092" for this rndum the urroorididanally Forantime pillyroart *=tedai chambers TAM by.any entity reaftV do*.Zill and so bftb**" Including 811101FIG10 IBM If didaft In paroard jor agnme Pay M*IorL. "alodal be made by afto 10. == OW 111110111410111 CMMKrkM Oft 121111 khme; Aimished foreurider Will" to herah Ow Peru" agree Z= be Saint k0cle Cmh*, Flodde, vwm IN wW Much action we It. Deallon rowerallialloo am per -manonig standard And Rilittegreaved Goidilame on R"Powbilltin For Construdlion Uft Mstild PM& Corrected WippITneo" AN8VrPIlWTCA4-2002-* DATEDL, ..A barmaybem"Par"Wsl plialarth*q&darrage, URMPIO Ply ULUM mug be ftstened togitherperengluggring b9lbrilt thgY 870 Sell fallure to do so can rebultin roa col bill Temporary and permanent bracing are rs*dmd and . can am Ift - and Propoi and Is the risponsibillty of the tmm erector. '81104 the contents of the bribirmation packet included an deftgry before setting trusses. .7hXd0@; mustbesetard Waged pickeignbpruientrilwa dourage. TnJ"" knust be set Plumb and square Do not"t bunks or stack of P"ood, FOOffn "rW Or any *lherC,*t*nbaW!2!ds Onftmwa, this can cause 22g!pse. - DO-AW SET TRUSSES USIMG THIS -USE LAYOUT DEUVERED VM TRUSSES TO SE CHAMBERS TRU66 INC 3105 Oleander Aienue FQrt'PI8r* Mdrida =82-64M 800-551-5932 Fort Pierce M-465-2012 Fax M-44154117111 Vero El"Ch 772469-2012 Stuart 11r2-nil Th@Ar0h4rsx;t'% 1(ArQhit*Ct'o reprosontativo-S Pht?P Ofalwl"D ApprovpI 10 NOT m "0@[4bj@ rhiaghu of thle controctor, CO"111600F Shall risr"pst, 046.0hing filq Arlo other cangtruttl4h CV110091, Archil Approvilil covore, g@m@fdl Vogt sihilipa, review Of tru a 11 Stfolrllpinif. and loading on structure fro," gravity Ond uPlIft loads and their re e tive 10 atio APProved B P.A. 92-0/93.2 MITEK 4,2 DESIGN CRITERIA County SAINT LUCIE Building Department ST LUCIE COUNTY Wind Design Criteria ASCE 7-2010 Wind Design Meffliod MVVFRS/C-C hybrid Wind ASCE 7­10 Roofing Material Shingle or Shako Loading in PSF Roof R.D.L. Top Chord Live 20 Top Chord Dead 7 42 Bottom Chord Live 10 Non -Concurrent Bottom Chord Dead 10 3 TOTAL Load 37 7.2 Duration Factor 1.25 Wind Speed 165mph Top Chord C.B. Sheeting by builder. Bottom Chord C.B. Sheeting by builder. Highest Mean Height IZ-00 Building Type ENCLOSED Building Category ll:Non Restrilctive Exposure Category C Barrier Island No Conforms to FBC 2017 R.D.L=Restreiirl Dead Load C.B.=Contriluoug Bracing Verify DESIGN CRITERIA shown above with the building department and your engineer. Design Criteria is the responsibility of the. Building Designer and/or Engineer of Record. Chambers Truss Inc. Drowing Name: M1 1412 Scale: 1/4 = 1' 73 total trusses, 18 different trusses. MI 4: RLC ACAD: RLC Reviewed By-_ Date: 11/14/16 Revilsed: 0=1118 FOR I I I I I I I I I WYNNE DEVELOPMENT CORP. '11K ��l TLV 5'-4- 15'-10* DESCRIPTION: G M A CARLTON 299 ARIAGE RIGHT PAGE 1 of 1 CUSTOMIM lNmA1LS EACH PAM 18 TRUSS DRAWINGS ARE ATTACHED TO LAYOUT M11412 r7j,=)r�tncy