HomeMy WebLinkAboutENERGY EFFICIENCY CODEFORM R405-2017
FLORIDA ENERGY EFFICIENCYMEI&OR BUILDING CONSTRUCTION
Florida Department of Business and Profession, al Regulation - Residential Performance Method
Project Name: WYNNE T�Wh-GRAND CARLTON Builder Name: WYNNE BUILDING COPR.
Street: k Permit Office: ST. LUCIE COUNTY
skZ
�Tk.4
City, State, Zip: E,�
Permit Number:
Owner: WYNNE BUILDING CROP
Jurisdiction: ST. LUCIE COUNTY
Design Location: FL, Fort Pierce
County:: St. Lucie (Florida Climate Zone 2
I . New construction or existing New (From Plans)
9. Wall Types(1442.0 sqft.)
Insulation Area
2. Single family or multiple family Single-family
a. Concrete Block - Ext Insul, Exterior
R=4.1 1250.00 ft2
b. Frame - Wood, Adjacent
R=1 1.0 192.00 ft'
3. Number of units, if multiple family 1
c. N/A
R= ft2
4. Number of Bedrooms 2
d. N/A
R= ft2
10. Ceiling Types (1446.0 sqft.)
Insulation Area
5. Is this a worst case? Yes
a. Under Attic (Vented)
R=30.0 1446.00 ft2
6. Conditioned floor area above grade (ft2) 1446
b. N/A
R= ft2
Conditioned floor area below grade (ft2) 0
c. N/A
R= ft2
11. Ducts
R ft2
7. Windows(141.3 sqft.) Description Area
a. Sup: Affic, Ret: Attic, AH: Attic
6 250
U Sgl, U=0.36
a -Factor: 101 . 25 ft2
SHGC: SHGC=0.25
b. U-Factor: SgI, U=0.65 40 .00 ft2
12. Cooling systems
kBtu/hr Efficiency
SHGC: SHGC=0.21
a. Central Unit
34.8 SEER:15.00
c. U-Factor: N/A ft2
SHGC:
13. Heating systems
kBtu/hr Efficiency
d. U-Factor: N/A ft2
a. Electric Heat Pump
34.8 HSPF:8.50
SHGC:
Area Weighted Average Overhang Depth: 3.832 ft.
Area Weighted Average SHGC: 0.239
14. Hot water systems
a. Electric
Cap: 40 gallons
8. FloorTypes (1445.5 sqft.) Insulation Area
EF: 0.970
a. Slab -On -Grade Edge Insulation R=0.0 1445.50 ft2'
b. Conservation features
b. N/A R= W"
None
c. N/A R= ft2
15. Credits
Pstat
Glass/Floor Area: 0.098 Total Proposed Modified Loads: 47.17
PASS
Total �Baseline Loads: 48.08
1 hereby certify that the plans and specifications coveredl'by
Review of the plans and
this calculation are in compliance with the Florida Energy
specifications covered by this
Olt
0
Code.
calculation indicates compliance
with the Florida Energy Code
PREPARN B
�:
DATE' �A
Before construction is completed
this building will be inspected for
compliance with Section 553.908
v
I hereby certify that this building, as designed, is in compliance
Florida Statutes.
with the Florida Energy Code.
0 M
OWNER/ E
BUILDING OFFICIAL:
DATE:
DATE:
- Compliance requires certification by the air han�dller unit manufacturer that the air handier enclosure qualifies as
I
certified factory -sealed in accordance with R403..3.2.1.
- Compliance requires an Air Barrier and Insulati6n Inspection Checklist in accordance with R402.4.1.1 and this project requires an
envelope leakage test report with envelope leakqge no greater than 7.00 ACH50 (R402.4.1.2).
4/17/2018 2:46 PM EnergyGaugeO USA - FlaRes2017 Section R405.4.1 Compliant Software Page 1 of 5
FORM R405-2017
I
PRO, I JECT
Title: WYNNE THE GRAND CARL Bedrooms: 2
Address Type:
Street Address
Building Type: User
Conditioned Areaml 1446
Lot #
Owner Name: WYNNE BUILDING CROP Total Stories: 1
Block/Subdivision:
# of Units: I
Worst Case: Yes
PlatBook:
Builder Name: WYNNE BUILDING COPR.
Rotate Angle: 180
Street:
Permit Office: ST. LUCIE COUNTY
Cross Ventilation: No
County:
St. Lucie
Jurisdiction: ST. LUCIE COUNTY
Whole House Fan: No
City, State, Zip:
FT. PIERCE,
Family Type: Single-family
FL,
New/Existing: New (From Plans)
Comment:
CLIMATE
V
Design Temp
Int Design Temp Heating
Design Daily Temp
Design Location
TMY Site 97.5%
2.5%
Winter
Summer Degree Days Moisture
Range
FL, Fort Pierce FL—VERO—BEACH—MUNI 39
90
70
75 299
62
Low
BLOCKS
Number Name
Area Volume
I Entire House
1446 11568
SPACES
Number Name -Area
Volume Kitchen Occupants
Bedrooms
Infil ID Finished Cooled
Heated
I BEDROOM
301 2408 No
0
1
1 Yes
Yes
Yes
2 WIC
63 504 No
0
1 No
Yes
Yes
3 M.BATH
56 448 No
0
1 Yes
Yes
Yes
4 KITCHEN
192 1536 Yes
0
1 No
Yes
Yes
5 BATH
45 360 No
0
1 Yes
Yes
Yes
6 BEDROOM 2
204 1632 No
0
1
1 Yes
Yes
Yes
7 ENTRY
55 440 No
0
1 Yes
Yes
Yes
8 LAUNDRY
42 336 No
0
1 Yes
Yes
Yes
9 GREAT/DINING
488 3904 No
0
1 Yes
Yes
Yes
FLOORS
y# Floor Type
Space Perimeter Perimeter R-Value
Area
Joist R-Value
Tile Wood
Carpet
1 Slab -On -Grade Edge Insulatio
BEDROOM 52 ft 0
301 ft2
----
0 1
0
2 Slab -On -Grade Edge Insulatio
WIC ift 0
63 ft2
----
0 1
0
3 Slab -On -Grade Edge Insulatio
M.BATH 8ft 0
56 ft2
----
0 1
0
4SIab-On-Grade Edge Insulatio
KITCHEN 1ft 0
192 ft2
----
0 1
0
5 Slab -On -Grade Edge Insulatio
BATH 5ft 0
45 ft2
----
0 1
0
6 Slab -On -Grade Edge Insulatio
BEDROOM 2 32.2 ft 0
203.5 ft2
----
0 1
0
7Slab-On-Grade Edge Insulatio
ENTRY 7ft 0
55 ft2
----
0 1
0
4/17/2018 2:46 PM EnergyGauge@) USIA - FlaRes2017 Section R405.4.1 Compliant Software Page 2 of 5
FORM R405-2017
FL60RS
- '
# Floor Type Space Perimeter Perimeter R-Value
Area
Joist R-Value
Tile
Wood Carpet
8 Slab -On -Grade Edge Insulatio LAUNDRY 6ft
0
42 ft2
----
0
1
0
9SIab-On-Grade Edge Insulatio GREAT/DINING 46ft
0
488 ft2
----
0
1
0
ROOF
Roof
Gable
Roof
Solar SA
Emitt
Emitt
Deck
Pitch
# Type Materials Area
Area
Color
Absor.
Tested
Tested
Insul.
(deg)
1 Gable or Shed Metal 1524 ft2
240 ft2
Light
0.6
No
0.9
No
0
18.4
AITTIC
V#
Type Ventilation
Vent Ratio (1 in)
Area
RBS
IRCC
1 Full attic Vented
150
1446 ft2
N
N
16EILING
V# Ceiling Type Space
R-Value
Ins Type
Area
Framing Frac Truss Type
1 Under Attic (Vented) BEDROOM
30
Blown
301 ft2
0.1
Wood
2 Under Attic (Vented) WIC
30
Blown
63 ft2
0.1
Wood
3 Under Attic (Vented) M.BATH
30
Blown
56 ft2
0.1
Wood
4 Under Attic (Vented) KITCHEN
30
Blown
192 ft2
0.1
Wood
5 Under Attic (Vented) BATH
30
Blown
45ft2
0.1
Wood
6 Under Attic (Vented) BEDROOM 2
30
Blown
204 ft2
0.1
Wood
7 Under Attic (Vented) ENTRY
30
Blown
55 ft2
0.1
Wood
8 Under Attic (Vented) LAUNDRY
30
Blown
42 ft2
0.1
Wood
9 Under Attic (Vented) GREAT/DINING
30
Blown
488 ft2
0.1
Wood
WALLS
Adjacent Cavity Width
it Ornt To 1AInli TVpp Space RA/ahle Et In
Height
Et In
Area
Sheathing Framing
R-1/ahle EraCt*on
Solar
AhSor
Below
G rafie%
I NE=>SW Exterior Concrete Block - Ext InsiflEDROOM
4.1 10
0 8
0
80.0 ft2
0
0
0.6
0
2 SW=>NE Exterior Concrete Block - Ext InsfHEDROOM
4.1 28
0 8
0
224.0 ft2
0
0
0.6
0
3 NW=>SE Exterior Concrete Block - Ext InsfHEDROOM1
4.1 14
0 8
0
112.0 ft2
0
0
0.6
0
4 SW=>NE Exterior Concrete Block - Ext InsulM. BATH
4.1 8
0 8
0
64.0 ft2
0
0
0.6
0
5 NE=>SW Exterior Concrete Block - Ext Insul BATH
4.1 5
0 8
0
40.0 ft2
0
0
0.6
0
6 NE=>SW Exterior Concrete Block - Ext InREDROOM12
4.1 16
0 8
0
128.0 ft2
0
0
0.6
0
7 SE=>NW Exterior Concrete Block - Ext IngEDROOM ; �2
4.1 10
0 8
0
80.0 ft2
0
0
0.6
0
8 S=>N Exterior Concrete Block - Ext In9EDROOM. 2
4.1 4
3 8
0
34.0 ft2
0
0
0.6
0
9 SW=>NE Exterior Concrete Block - Ext InfiEDROOM 2
4.1 2
0 8
0
16.0 ft2
0
0
0.6
0
10 SE=>NW Exterior Concrete Block - Ext Insul ENTRY!
4.1 6
0 8
0
48.0 ft2
0
0
0.6
0
11 SW=>NE Exterior Concrete Block - Ext Insul ENTRY,'
4.1 1
0 8
0
8.0 ft2
0
0
0.6
0
12 SW=>NE Exterior Concrete Block - Ext lnsLILAUNDkY
4.1 6
0 8
0
48.0 ft2
0
0
0.6
0
13 NE=>SW Exterior Concrete Block - Ext InsGREAT/01NI
4.1 26
0 8
0
208.0 ft2
0
0
0.6
0
14 NW=>SE Exterior Concrete Block - Ext InsGREAT/DINI
4.1 20
0 8
0
160.0 ft2
0
0
0.6
0
15 N=>S Garage Frame - Wood KITCHEN
11 24
8
192.0 ft2
0.23
0.6
0
4/17/2018 2:46 PM
EnergyGauge@ USA
FlaRes2017 Section R405.4.1 Compliant Software
Page 3 of 5
FORM R405-2017
D6oRs
# Ornt
Door Type Space
Storms U-Value Width
Ft In
Height
Ft In
Area
1 SE=>NW
Insulated ENTRY
None .39 3 1
6 8
20.6 ft2
WINDOWS
Orientation shown is the entered orientation (=>) cha2gedjtoajWjo2rsstLCase.
Wall
V- # Ornt ID Frame
Panes NFRC
I I Overhang
U-Factor SHGC Imp Area Depth Separation Int Shade
Screening
1 NW=>SE 3 Metal
2 SW=>NE 4 Metal
3 SE=>NW 7 Metal
4 NE=>SW13 Metal
5 NW=>SE14 Metal
Low-E Single Yes
Low-E Single Yes
Low-E Single Yes
Low-E Single Yes
Low-E Single Yes
0.36 1 0.25 N 32.9 ft2 1 ft0in 1 ft4 in
0.36 0.25 N 6.9 ft' 1 ftO in I ft 4 in
U.ao 0.25 N 24.0 ft2 6 ft 0 in 1 ft4 in
u.;Jb 0.25 N 37.5 ft2 1 ft 0 in 1 ft 4 in
0.6 1 5 0.21 N 40.0 ft2 8 ft 0 in 1 ft 4 in
Drapesiblinds
None
None
None
Drapes/blinds
Exterior 5
None
None
None
Exterior 5
GARAGE
y # Floor Area
Ceiling Area
i
Exposed Wall Perimeter Avg. Wall Height Exposed Wall Insulation
1 315 ft2
315 ft2
24 ft 8 ft
11
IN FILTRATION
# Scope Method
SLA
CFM f5'0 ELA EqLA ACH ACH 50
1 Wholehouse Proposed ACH(50) .000356
1349 ! .6 74.09 139.34 .2598
7
HEATING SYSTEM
y # System Type
Subtype
Efficiency Capacity
Block
Ducts
1 Electric Heat Pump/ Split
HSPF:8.5 34.8 kBtu/hr
1
sys#1
COOLING SYSTEM
y # System Type
Subtype
Efficiency Capacity Air Flow
SHR Block
Ducts
1 Central Unit/
Split
SEER: 15 34.8 kBtu/hr cfm
0.8 1
sys#1
HOT WATER SYSTEM
y# System Type
SubType Location
EF Cap Use SetPnt
Conservation
I Electric
None Garage
0.97 40 gal 60.9 gal 120 deg
None
SOLAR HOT WATER SYSTEM
FSEC
Cert # Company Name
I I Collector
System Model # Collector Model # Area
Storage
Volume FEF
None None
11 ft2
4/17/2018 2:46 PM EnergyGauge@ USA' FlaRes2017 Section R405.4.1 Compliant Software Page 4 of 5
FORM R405-2017
D6CTS
-- Supply
----
---- Return
Air
CFM 25
CFM25
HVAC #
# Location R-Value
Area
Location
Area
Leakage Type
Handler
TOT
OUT
QN
RLF
Heat Cool
1
Attic 6
250 ft2
Attic
65 ft2
Default Leakage
Attic
(Default) (Default)
1 1
TEMP �RATURES
Prograrnable Thermostat: Y
Ceiling Fans:
Cooling Jan
Heating Jan
Feb
[)q Feb
Mar
Mar
ki
Apr
A pr I
M:y
JM y Jun
'rj Jun
Jul
Jul
ri
A
rl Aug
il 8:p
Oct
Oct
H Nov
Nov
Dec
Dec
Venting Jan
[ ] Feb
Mar
Apr
May
Jun
Jul
Aug
Sep
Oct
X Nov
Dec
Thermostat Schedule:
HERS 2006 Reference
Hours
—
Schedule Type
1
2
3
4
5
6
7
8
9
10
11
12
Cooling (WD)
AM
78
78
78
781
78
78
78
78
80
80
80
80
PM
80
80
78
781
78
78
78
78
78
78
78
78
Cooling (VVEH)
AM
78
78
78
781
78
78
78
78
78
78
78
78
PM
78
78
78
781
78
78
78
78
78
78
78
78
Heating (WD)
AM
66
66
66
1
615
66
68
68
68
68
68
68
68
PM
68
68
68
68
68
68
68
68
68
68
66
66
Heating (VVEH)
AM
66
66
66
66
66
68
68
68
68
68
68
68
PM
68
68
68
68
68
68
68 ,
68
68
68
66
66
4/17/2018 2:46 PM EnergyGauge@ U ; SA - FlaRes2017 Section R405.4.1 Compliant Software Page 5 of 5
4;
2017 - AIR BARRIER AND INSULATION INSPECTION COMPONENT CRITERIA
TABLE 402.4.1.1
AIR BARRIER AND INSULATION INSPECTION COMPONENT CRITERIA
Project Name: WYNNE THE GRAND CARLTON Builder Name: WYNNE BUILDING COPR.
Street: Permit Office: ST. LUCIE COUNTY
City, State, Zip: FT. PIERCE, FL, Permit Number:
Owner: WYNNE BUILDING CROP Jurisdiction: ST. LUCIE COUNTY
Design Location: FL, Fort Pierce
COMPONENT
AIR BARRIER CRITERIA
INSULATION INSTALLATION CRITERIA
General
A continuous air barrier shall be installed in the building envelope.
Air -permeable insulation shall
The exterior thermal envelope contains a continuous air barrier.
not be used as a sealing material.
requirements
Breaks or joints in the air barrier shall be sealed.
Ceiling/attic
The air barrier in any dropped ceiling/soffit shall be aligned with
The insulation in any dropped ceiling/soffit
the insulation and any gaps in the air barrier shall be sealed.
shall be aligned with the air barrier.
Access openings, drop down stairs or knee wall doors to
unconditioned attic spaces shall be sealed. -
Walls
The junction of the foundation and sill plate shall be sealed.
Cavities within corners and headers of frame walls
The junction of the top plate and the top of exterior walls shall be
shall be insulated by completely filling the cavity with
sealed.
a material having a thermal resistance of R-3 per inch
Knee walls shall be sealed.
minimum.
Exterior thermal envelope insulation for framed walls
shall be installed in substantial contact and
continuous alignment with the air barrier.
Windows, skylights
The space between window/doorjambs and framing, and
and doors
skylights and framing shall be sealed.
Rim joists
Rim joists shall include the air barrier.
Rim joists shall be insulated.
Floors
The air barrier shall be installed at any exposed edge of
Floor framing cavity insulation shall be installed to
(including
insulation.
maintain permanent contact with the underside of
above -garage
subfloor decking, or floor framing cavity insulation
and cantilevered
shall be permitted to be in contact with the top side
floors)
of sheathing, or continuous insulation installed on
the underside of floor framing and extends from the
bottom to the top of all perimeter floor framing
members.
Crawl space walls
Exposed earth in unvented crawl spaces shall be covered with
Where provided instead of floor insulation, insulation
a Class I vapor retarder with overlapping joints taped.
shall be permanently attached to the crawlspace walls.
Shafts, penetrations
Duct shafts, utility penetrations, and flue shafts opening to
exterior or unconditioned space shall be sealed.
Batts in narrow cavities shall be cut to fit, or narrow
Narrow cavities
cavities shall be filled by insulation that on
installation readily conforms to the available cavity
spaces.
Garage separation
Air sealing shall be provided between'the garage and conditioned spac
I
as.
Recessed lighting
Recessed light fixtures installed in the' building thermal envelope
Recessed light fixtures installed in the building
shall be sealed to the drywall.
thermal envelope shall be air tight and IC rated.
Plumbing and wiring
Batt insulation shall be cut neatly to fit around wiring
and plumbing in exterior walls, or insulation that on
installation readily conforms to available space shall
extend behind p4ping and wiring,
Shower/tub
The air barrier installed at exterior walls adjacent to showers and
Exterior walls adjacent to showers and tubs shall
on exterior wall
tubs shall separate them from the showers and tubs.
be insulated.
Electrical/phone box or
The air barrier shall be installed behind electrical or communication
exterior walls
boxes or air -sealed boxes shall be installed.
HVAC register boots
HVAC register boots that penetrate building thermal envelope shall
be sealed to the sub -floor or dryw�ll.
Concealed
When required to be sealed, concealed fire sprinklers shall only be
sprinklers
sealed in a manner that is recomr�ended by the manufacturer.
Caulking or other adhesive sealants shall not be used to fill voids
between fire sprinkler cover plates and walls or cemlongs-
a. in addition, inspection of log walls shall be in accordance with the provisions of ICC-400.
4/17/2018 2:46 PIVI EnergyGaugeS USA FlaRes2017 FBC 6th Edition (2017) Compliant Software Page I of 1
PORM R405-2017
ENERGY PERFORMANCE LEVEL (EPL)
I
DISPLAY CARD
ESTIMATED ENERGY P ERFORMANCE INDEX* = 98
The lower the EnergyPerformance Index, the more efficient the home.
I . New construction or existing
2. Single family or multiple family
3. Number of units, if multiple family
4. Number of Bedrooms
5. Is this a worst case?
6. Conditioned floor area (ft)
7. Windows-
Description
a. U-Factor:
SgI, U=0.36
SHGC:
SHGC=0.25
b. U-Factor:
Sgl, U=0.65
SHGC:
SHGC=0.21
c. U-Factor:
N/A
SHGC:
d. U-Factor:
N/A
SHGC:
Area Weighted Average Overhang Depth
Area Weighted Average SHGC:
I FT. PIERCE, FL,
New (From Plans)
Single-family
1
2
Yes
1446
Area
101.25 ft2
40.00 ft2
ft2
ft2
8. Floor Types Insulation
a. Slab -On -Grade Edge Insulation R=0.0
b. N/A R=
c. N/A R=
3.832 ft.
0.239
Area
1445.50 ft2
ft2
ft2
9. Wall Types
a. Concrete Block - Ext Insul, Exterior
b. Frame - Wood, Adjacent
c. N/A
d. N/A
10. Ceiling Types
a. Under Attic (Vented)
b. N/A
c. N/A
11. Ducts
a. Sup: Attic, Ret: Attic, AH: Attic
12. Cooling systems
a. Central Unit
13. Heating systems
a. Electric Heat Pump
14. Hot water systems
a. Electric
b. Conservation features
None
15. Credits
Insulation
R=4.1
R=1 1.0
R=
R=
Insulation
R=30.0
R=
R=
Area
1250.00 ft2
192.00 ft2
ft2
ft2
Area
1446.00 ft2
ft2
ft2
R ft2
6 250
kBtu/hr Efficiency
34.8 SEER:15.00
kBtu/hr Efficiency
34.8 HSPF:8.50
Cap: 40 gallons
EF: 0.97
Pstat
I certify that this home has complied with the Florida Energy Efficiency Code for Building -tliE S�4j,
Construction through the above energy saving features which will be installed (or exceeded) 0&
in this home before final inspection. Otherwise, a new EPIL Display Card will be completed
based on installed Code compliant features.
Builder Signature: Date:
Address of New Home\.6� City/Fl-
01) W-6
*Note: This is not a Building Energy Rating. If your' Index is below 70, your home may qualify for energy efficient
mortgage (EEM) incentives if you obtain a Florida EnlergyGauge Rating. Email EnergyGauge tech support at
techsupport@energygauge.com or see the Energyqauge web site at energygauge.com for information and a list of
certified Raters. For information about the Florida Building Code, Energy Conservation, contact the Florida Building
Commission's support staff. I I
**Label required by Section R303.1.3 of the Florida i building Code, Energy Conservation, if not DEFAULT.
4/17/2018 2:46 PM EnergyGauge@ USA - maKes2ul 7 - Section R405.4.1 Compliant Software Page 1 of 1