Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
PROJECT INFORMATION
Project 'Summary Job: wrightsofte Date: Enfire House By: QUICK CALCS, INC. A;1Jfi0JcJPt11S 317 ST. LUCIE LN., FT PIERCE, FL 34946 Phone: 77 1 2-4 . 66-6799 Pax 772-466-67R . Email: QUICKQpd;lg 6&� For: Notes: I N\ Q01& C�q Weather: Winter Design Conditions Outside db 42 OF Inside db 70 OF Design TD 28 OF Heating Summary Structure 17848 Btuh Ducts 5654 Btuh Central vent (0 cfm) 0 Btuh (none) Humidification Plplqg Equipment load Infiltration Method Construction quality Fireplaces 0 Btuh 0 Btuh 23503 Btuh He%"g Area (ft2) 1 Volume (ft') le-0 I I Air change&hour 0.45 Equiv. AVF (cfm) 94 Heating Equipment Summary Make Carrier Trade CARRIER AIR CONDITIONING Model 25HBC536A*030 AHRI ref 7914585 Efficiency Heat'ng.input Heating output Temperature rise Actual air flow Air flow factor Static pressure Space thermostat Capacity balance point 32 OF Back 48 Fr. PIERCE, FL Pierce, FL, US 8.15 HS1,311 34600 Btu� @ 47-F 27 OF 1 1160 cfml 0.049 cfm/Btuh 0.50 in H20 Input =i 7 W, Output = 23009 Btuh, 100 Calculations approved Summer Design Conditions Outside db 90 OF Inside db 75 OF Design TD 15 OF Daily range L Relative humidity 50 % Moisture difference 61 gr/lb Sensible Cooling -Equipment Load Sizing Structure 17520 Btuh Ducts 8536 Btuh Central vent (0 cfm) 0 Btuh (none) Blower -0 Btuh Use manufacturer's data n Rate/swin multiplier 0.95 Equiomen?sensible load 24753 Btuh Latent Coolirig-Equip'me'rit Load Sizing Structure 3203 Btuh Ducts 2318 Btuh Central vent (0 cfm) 0 Btuh (none) Equipment latent load 5521 Btuh Equipment total load 30274 Btuh Req. total capacity at 0.70 SHR 2.9 ton Cooling Equipment Summary Make - Carrier Trade CARRIER AIR CONDITIONING Cond 25HBC536A*030 Coil FX4DN(B,F)037 AHRI ref 7914585 Efficiency 12.0 EER, 15 SEER Sensible cooling 24360 Btuh Latent cooling 10440 Btuh Total coolin 34800 Btuh Actual air flow 1160 cfm Air flow factor 0.045 cfm/Btuh Static pressure 0 , 50 in H20 Load sensible heat ratio 0.83 to meet all requirements of Manual J 8th Ed. I wrightsoft, Right-Sufte(b Universal 2017 17. 1 b.14 RSU08101 ACM I ... uick Calcs%Documents%THE GRAND CARLTON-1446.rup Calc = M.18 Front Door faces: N 2017-Apr-11 09:29:38 Page 1 wrightsoft Right-J@ Worksheet Job: Endre House Date: By: QUICK CALCS, INC. 317 ST. LUCIE LN., FT PIERCE, FL 34946 Phone: 772-466-6799 Fax 772-466-6796 Ernall: QUICKCALCS@AOL.COM I I Room name Entire House BEDROOM 2 Exposed wall 156.2 ft 49.0 ft 3 Room height 8.7 ft d 8.0 ft heat/cooll 4 5 Room dimensions Room area 1445.5 ft2 1.0 x 297.0 ft 297.0 ft2 TY Construction Ll-value Or H M Nlea (ft2) Load Area (ft-) Load number (Btuh/ftk-0F) (Btu W) or perimeter (ft) (Btuh) or perimeter (ft) (Btuh) Heat Cool Gross N/P/S Het Cool Gross NIPIS Heat Cool 6 'w L_4� 114,4ocs 0. 143 n' .4.001: 2.55 50 465 18 62, 1184 72 72- 28 . 8 183 .4,11&2om .0.770 0. 143 n' e '.'21.56. 4.00 .19.31 2.55 -.38 128 �O 83 815 333 730 212 0'. 0 0 10 0 0 0 1� �:13A4ocs Z. IA-clorn 11DO 1.270 0.390 a e 35.56 10.92 87.29 11.31 24 21 2 21 848 229 2082 238 0 0 0 0 0 0 0 0 W Y-a 13A4ocs 13A4ocs IA-clorn 0143 0143 1.*270 se s s 4.00, 4.00 35.56 2.55 2.55 34.77 34 360 7 34 353 7 136 1414 247 86 899 241 0 216 0 0 216 0 .0 865 0 0 550 0 IL27 '13�4ocs 0.143 vv 4.00 2.55 310 237 949 603 104 72 286 183 1A-clorn 1.270 w 35.56 55.21 32 2 1140 1770 32 2 1140 1-77.0 -4A5-2om:. 12C-Osw :16A�30md .0.770 0.091 -0.032 w - - 21.56 2.5.5 .0; : * 90 .19.31 1.28 2.1n 41.. 192 1446 41 192 1446- 880 489 1295. 788 246 3354 0- 0 297. 0 0, 297- 0 0 266 - -0 0 689 P c F 22A-tp] 0.9139 - 27.69 0.00 1446 p 156 4325 0 297 49 1357 0 6 c)AED emursion 918 627 Envelope loss/gain 14961 13349 4204 4003 12 a) Infiltration 2887 791 848 232 b) Room ventilation 0 0 0 0 113 13 Internal gains: Occupants @ 230 6 1380 3 690 Appliances/other 20DO 0 Subtotal Oines 6 to 13) 17848 175201 5053 4925 Less e)demal load 0 0 0 0 4 1 1 Less transfer Redistribution Subtotal 0 0 17848 0 0 17520 0 0 6053 0 0 4925 Duct loads 32% 49% 5654 8536 32% 49% 1601 2400 r15 Total room load Air required (cfm) 1. 1 23503 11601 26056 1160, . . I I 6653 , 3281 7325 .149r, i Calculations approved by AC C.A. to ryieet all re�quir wrightsc3ift- AMK Right -Suite@ Universal 2017 17.0.14 RSU08101 uIck CalcskDocuments\THE GRAND CARLTON-1446.rup Calc = MJ8 Front Door faces: N I 2017-Apr-11 09:29:38 Page 1 wrightsoft- Right-.J@ Worksheet Job: Entire House Date: QUICK CALCS, INC. By: 317 ST. LUCIE LN., FT PIERCE, FL 34946 Phone: 772-466-6799 Fax 772-466-6796 Email: QUICKCALCS@,AOL.COM 1 2 3 4 5 Room name =ad wall height Room dimensions Room area WIC 0 ft 8.0 ft heat1cool 6.0 x 9.0 ft 1 54.0 ft2 KrrCHEN 0 ft 8.0 ft heat/coot 1.0 x 172.0 ft 17ZO f12 Ty Construction number U-value (Eltuhff?�-*F) Or HTM ERU 2) .(Btu (ft2) or perimeter (ft) Lo ad (Btuh) Area (ft2) or perimeter (ft) Load (Btuh) Heat Cool Gross NIPIS Heat Cool Gross N/PIS Heat Cool 6 1 OAAocs' rO 0.143 a '.4'00 21.56 4.00 2.55 101 2.55 '0 0 0 0 0;,. 0 ;�o �0 0 01 0 1 �O U.. a �0. 0 7 0 "D '0 0 'L13AAocs 1� IIA-clorn 11DO M-40ps IA-clom '13AAocs 1X'clorn 4A5�2orfi 12C-Osw 'A 6A�30md 1.270 0,390 0.143 o.149 1.270 .-0.143 1.270 .0.770 0.091 0.032 0.989 a e se. s s w w w 35.56 10.92 4.00 4.00 35.56 4;00 35.66 21.56 2.55 A90 27.69 87.29 11.31 2.55 2.55 34.77 2.55 55.21 19.31 1.28 2.32 0.00. 0 0 0 0 0 0 0 0 0 54% 54 0 0 0 0 0 .0 0 0. 0 54 0 0 0 0, 0 0 0 0 0 0 48 0 0 0 0 0 0 .0 0 .0 0 125 0 0 0 0 0 0 0 b 0 64 .172 17.2 0 0 0 0 0 0 o 0 64 - 172. 0 0 0 .0 0 0 -0 0 0 163 , ,,.'154 0 0 0 0 0 0 .0 0 82 399 0 -G Z W t13AAoGs -G 16 ; P Ct. 4- 6 6 c)AED emursion -9 -170 Envelope loss/gain 48 117 317 311 ]12 a) Infiltration b) Room ventilation 0 0 0 0 0 0 0 0 11 3 Internal gains: Occupants @ 230 1 Appliances/other 0 0 0 0 0 2000 Subtotal Pines 6 to 13) 1 48 117 317 2311 14 15, Less e)demal load Less transfer Redistribution Subtotal Duct loads 1 32% 49% 0 0 0 48 15 0 0 0 1171 57 32% 49% .0 0 0 317 100 1 0 0 0 2311 1126 Total room load Air required (cfm) L I I 64 . 3 1741 8 _ 418 . 211 3437 153 Of -Ft+- wrigh - I ts'olft Right-S6iteO Universal 2017 17' 0.14 RSU08101 ... uick Caics\Documents\THE GRAND CARLTON-1446.rup CalcLMJa FrontDcorlaces: N 7 2017-Apr-11 09:29:38 Page 2 AL FF wrightsoft, Right-M Worksheet Entire Hodse QUICK CALCS, INC. 317 ST. LUC I E LN., FT PIERCE, FIL 34946 Phone: 772-466-6799 Fax 772-466-6766 Email: QUICKCALCS@AOL.COM Job: bate: By: 1 Room name BATH BEDROOM 2 2 Msed wall 5.0 ft 34.2 ft 3 height 8.0 ft heat/cool 8.0 ft heat/cool 4. 5 Room dimensions Room area 9.0 x 5.0 ft 45.0 ft2 1.0 x 203.5 ft 203.5 ft2 - Ty Constniction LI-value Or H M A, rea (ft2) Load Area (ft2) Load number (BtuWft2L-* F) (Btu 1) �r perimeter (ft) (EBRt h) or perimeter (ft) (Btuh) Heat Cool I Gross N/PIS Heat I Cool Gross N/P/S Heat cool 6 1 'Ll13A4ocs 13A4cc -s' �4M�26� 0* 143 0 ;770 0.143 n e 14M �11`56 4.00 i55 '19 11 E55 40 0 4% 0 160.: 0 102 .0 0 128 '0 80 128 :,.,0: 56 225 326, 0 143 1� -D IIA-clorn .11130 13A4ocs 13A4ocs IA-clorn 13AAocs '1A�ciorn 1.270 0.390 0.143: 0.143 1.270 -0.1143 1;270 e e se s s vi - w 35.56 10.92 .4.00 4.00 36.56 4.00 35.56 87.29 11.31 2.55 2.55 34.77 2.55 55.21 0 0 0 0 0 0- .0 0 0 .0 0 0 0 6 0 0 0 0 0 0 0 0 0 0 0 0 0 .0 24 0 34 32 0 0 0 2 0 .34 32 0 0 .0. 848 0 136 128 0 .0 '0 2082 0 86 81 0 0 W - t-G 12C-Gsw .0.,-7770 0.091 0.032 w - - �211.56 2.55 ---,0.90 �19.311 1.28 Z32 0 0 -45' 0 -45 Wi 0: 0 4U A 0 104 .6 0 204, 6. 0 20.4..- 0 0 162:'.-'- 0 0 472. P F 22A-tPI X. 27.69 o'.cb 45 5 138 0 204, 34 946 0 r . 6 c)AED emursion -16 -85 Envelope loss/gain 339 190 2978 3106 12 a) Infiltration b) Room ventilation 87 0 24 0 593 0 162 0 13 Internal gains: Occupants @ 230 0 0 1 230 Appliances/other 01 0 Subtotal Oines 6 to 13) 425 214 3571 3498 14 .16, Less e)demal load Less transfer io Redistribut n Subtotal Duct loads 320/6 49% 0 0 0 425 135 0 0 0 214 104 320/c 49% 0 0 0 3S71 1131 �0 0 0 3498 17 . 04 -1 Total room load Air required (cfm) 1 1 560 281 3181 14 1 4702 2.1 52203231 Calculafions approved by ACCA to meet all reauirements of Manual J 8th Ed. _,7- -Fi:f- wrightsoft I Aeek Right -Suite@ Universal.2017 17.0.14 RSU08101 ... ujck CaIcs%DocumentMTHE GRAND CARLTON-1446.rup Cale = MJ18 Front Door faces: N 2017-Apr-11 09:29:38 Page 3 wrlightsoft- Right4@ Worksheet Entire H66se � QUICK CALCS, INC. 317 ST. LUCIE LN., FT. PIERCE, FL 34946 Phone: 772-46"799 Fax 772-466-67�6 Emil: QUICKCALCS@,AOL.COM Job: Date: By: I Room name LAUNDRY GREATIDINING 2 Exposed wall 6.0 ft 47.0 ft 3 Room height 8.0 ft heat/cool 9.8 ft heat/cool 4 Room dimensions 7.0 x 6.0 ft 1.0 x 526.0 ft 5 Room area 42.0 ft2 526.0 ft2 Ty Construction U-Value Or HTM A, rea (ft2) Load Area (ft2) Load number (BtutVft2L-'F) (Btuh/ft2) qr perimeter (ft) (Btuh) or perimeter (ft) (Btuh) Heat cool 6ross N/P/S Heat cool Gross N/P/S Heat cool 6 W..' 134�11bcs-. - n 255 '0 0 0 0: 255 217 .4A&2om: 0.iii --�56 1931 0 ..0 0 i 38'-' �A S 15, _552 730 13AAocs 0. 143 a 4.00 2.65 0 0 0 0 0 0 0 0 1A-clom 1.270 e 35.56 87.29 0 0 0 0 0 0 0 0 1� 11DO 0.390 e 10.92 11.31 0 0 0 0 0 0 0 0 W -1,3AAocs 0.143 se 4.00 2.55 0 0 0 0 0 0 z 0 VL13AAocs; S 0.143 s 400 2.55 48 48 192 122 0 0 0 0 1A-clorn 1.270 s 35*56 34.77 0 0 0 0 0 0 0 0 ;'13AAocs 0.143 w 4.'00 2.55 0 .0 0 0 206 165 661' 420 %clorn 1.270 ' w 35.56 5521 -0 0 0 0 0 .0 .0 0 4A546n' 0.770, w 21M 1§31 0 0.: 0, .0 41 41 880%. -:788 P 12C-Osw 0.091 2.55 1.28 56 66 143 72 0 0 0 0 :-C -16A : -30md. -p 6..032 0.90 2;32 *42 -42 38 97 .526 526, ._471� F '22A-tpl 0.9a 27.69 0.00 42 p 0 526 47 13,02 p ..1220 0 6 c)AED enursion -�2 668 - Envelope loss/gain 539 270 4997 43791 12 a) Infiltration 104 M 997 273 b) Room ventilation 0 0 0 13 Intemal gains: Occupants @ 230 0 0 2 460 Appliances/other 0 0 Subtotal Pines 6 to 121) 1 643 298 59941 5112 Less e)demal load 0 0 0 0 Less transfer 0 0 0 0 Redistribution 0 01 0 0 14 Subtotal 643 298 5994 5112 15 Duct loads 32% 49% 204 145 32% 49% 2490 Total room load .1899 7892 7602 Air required (cfm) to meet all Ed. -ItIl- wrightsc3ift Right -Suite@ Universal 2017 17.0.14 RSUD8101 ....Ick CalcsIDocuments%THE GRAND CARLTON-1446.rup Calc = MJ8 Front Door ftces: N 2017-Apr-11 09:29:38 Page 4 + wrightsoft, RighWO Worksheet� Job: Entire Ho use Date: By: QUICK CALCS, INC. 317 ST. LUCIE LN., FT PIERCE, FL 34946 Phone: 772-466-6799 Fax 772-466-6796 E.il: QUICKCALCS@AOL.COM I I 2 3 4 5 Room name Msed wall height Room dimensions Room area FOYER 7.0 ft 8.0 ft heat1cool 1.0 x 50.0 ft 50.0 ftz M. BATH 8.0 ft 8.0 ft heat/cool 7.0 x 8.0 ft 56.0 ft' Ty Construction number U-value (BtulVftl,-*F) Or HTM (Btu 2) �rea (ft') Or perimeter (ft) Load (EBRIt h) Area (ft') or perimeter (ft) Load (Btuh) Heat Cool Gross N/PIS Heat Cooll Gross N/P/S Heat Cool 6 I 6' TL13AAocs D .W -G P �C - F w 1 8A-4ocs 4 1A-clom 11DO .13A46cs 13AAocs 1A-clom �13A4&s 1A-clom. 4A5-2orn 12C-Osw �-�16A ,30ind �22A-tpl 0.143 :0.770 0.143 1.270 0.3,90 0.143 0.143 1.270 0.143 1 ' 270 .0.770, 0.091 6.'03� 0.989 n-' e e e se s s w w w - 4.,00 4.06 35.56 10.92 4.00 4.00 35.56 4.00, 35.56.. 21.56 2.55 �0.190_ 2�.69 '2.55 16.'81 2.55 87.29 11.31 2.55 255 34.77 2.55 55.21 19.31 1.28 2.32 0.66 .8 A 48 0 21 0 0 0 0 0 0 72 :50 �O 8 27 0 21 0 0 0 0 0 0. 72. --50 7 32 0 108 0 229 0 0 0 0 0 0 183 45'. 194 20- 0 69 0 238 0 0 0 '0 0 0. 92 .116 0 0 0 0 0 0 64 7 0 0 0 56 `0 0. 0 0 0 0 57 7 0 0:' 0 0 56 8 0 0 0 0 228 247 0 6 0 -:60 222 "o 0 0 0 - D 145 241 0( .0 0, 0 %iab 0 6 c)AED wcursion -39 -38 - Envelope loss/gain 79 . 2 4961 747 478 12 a) Infiltration b) Room ventilation 121 0 33 0 138 0 38 0 13 Internal gains: Occupants @ 230 Appliances/other 0 0 0 0 0 Subtotal Oines 6 to 13) 913 529 885 51 . 6 14 1151 Less e)demal load Less transfer Redistribution Subtotal Duct loads 1 1 32% 49% 0 0 0 913 289 0 0 0 529 258 32%.. 49% 0 0 0 885 280 0 0 0 516 251 Total room.load Air required (cfm) 1202 .591 787 351 1 1 11661 58 768 341 8th Ed. -,:-- � -Pff- wrightse3ift- I .&-FA Right -Suite@ Universal 2017 17.0.14 RSU08101 ... uick CalcsIDocumentsITHE GRAND CARLTON-1446.rup Calc = MJ8; Front Door faces: N 2017-Apr-11 09:29:38 Page 5 wrightsoft, Duct System Summ�� Entire House QUICK CALCS, INC. 317 ST. LUCIE LN., FT PIERCE, FL 34946 Phone: 772-46"799 Fax 7_72-46"7g6 Ernail: QUICKC4CS@,AqL.COM For: THE GRAND CARLTON I WYNNE DEVELOPMENT, IFT PIERCE, FL External static pressure Pressure losses Available static pressure Supplyt return available pressure Lowest friction rate Actual air flow Total effective length (TEL) Heating 0.50 in H20 0 in H20 ,0.50 in H20 0.250 / 0.250 in H20 0.285 in/100ft 1160 cfm Job: Date: By: Cooling 0.50 in H20 0 in H20 0.50 in H20 0.250 / 0.250 in H20 0.285 in/1 00ft 1160 cfm 176 ft Name Design (Btuh) Htg (Cfm) CIg (Cfm) Design 1#1 R Diam (in) HxW (in) Duct Matl Actual Ln (ft) Ftg.Eqv Ln (ft) Trunk 13ATH h 560 28 14 I 0.1364 4.0 - ox 0 VIFx 22.4 115.0 sti BEDROOM 2 h 4702 232 232 0360 7.0 Ox 0 V1Fx 23.9 115.0 sti BEDROOM -A h 3327 164 163 0 ' 300 6.0 Ox 0 VIFx 31.8 135.0 st2 BEDROOM-B h 3327 164 163 0.1285 6.0 OxO VIFx 40.6 135.0 st2 FOYER h 1202 59 35 0.505 4.0 Ox 0 VIFx 4.0 95.0 GREATIDINING h 3946 195 169 0.300 7.0 Ox 0 VIFx 31.8 135.0 st2 GREATIDINING-A h 3946 195 169 0.300 7.0 Ox 0 VIFx- 31.8 135.0 st2 KITCHEN c 3437 21 153 0.379 6.0 OX0 VIFx 17.0 115.0 stl LAUNDRY h 846 42 20 0.1361 4.0 ox 0 VIFx 23.3 115.0 sti M. BATH -A h 768 58 34 �- 0 0 Ox 0 VIFx 0 0 WIC C 174 3 8 P09 4.0 OxO VIFx 27.0 135.0 st2 Trunk Htg CIg Design Veloc Diam HxW Duct Name Type (cfm) (cfm) FR Upm) (in) (in) Material Trunk st2 Peak AVF 721 672 0.285 918 12.0 0 X 0 VinIFIx 'sti sti Peak AVF 1043 1091 0.285 1 1020 14.0 0 X - 0 VinIFIx wrightsoft, Right -Suite@ Universal 2017 17.0.14 t i $1 ul 2017-Apr-11 09:29:38 117u Page 1 ... uick Calcs\Documents\THE GRAND CARLTON-1446.rup Calc MJ8 Iront Door faces: N Grille Htg CIg TEL Design Veloc Diam HxW Stud/Joist Duct Name Size (in) (cfm) (cfm) (ft) FR (fpm) (in) (in) Opening (in) Mat Trunk rbI OX0 1160 1160 0 0 0 0 Ox 0 VIFx + wrightsoft, , Right -Suite@ Universal 2017 17.0.14 RSt ACCA ... uick Caics\Documents\THE GRAND CARLTON-1446.rup Calc = MJ8 Door faces: N 2017-Apr-11 09:29:38 Page 2