HomeMy WebLinkAboutTRUSSLumber design values are in accordance with ANSI/TPI 1 section 6.3 hese truss designs rely on lumber values established by others. 4 MiTek RE: M1 1412 - CARLTON 299 Site Information: Customer Info: Wynne Development Lot/Block: Address: unknown City: St Lucie County Name Address and License # of Stir Name: Address: City: NO, 43, MITek USA, Inc. 6904 Parke East Blvd. rp Project Name: Carlton 299 Model: Tampa, FL 33610-4115 Subdivision: State: FL ural Engineer of Record, If there is one, for the building. License #: State: General Truss Engineering Criteria Design Loads (individual Truss Design Drawings Show Special Loading Conditions): Design Code: FBC2017ITP12014 Design Program: MiTek 20/20 8.1 Wind Code: ASCE 7-10 Wind Speed: 165 mph Roof Load: 37.0 psf Floor Load: N/A psf This package includes 18 individual, dated Truss Design Drawings and 0 Additional Drawings. With my seal affixed to this sheet, I he�eby certify that I am the Truss Design Engineer and this index sheet conforms to 61 G 15-31.003, section 5 of the Florida Board of Professional Engineers Rules. I No. I Seal# I Truss Name I Date I I No. I Seal# I Truss Name I Date 1 11 IT135696111A 13/22/181 118 1 T1 3569628 1 KJAB 13/22/18 0 12 1 T1 3569612 1 Al 13/22/181 1 1 1 1 1 13 T1 3569613 1 A2 13/22/181 14 T1 3569614 1 A3 13/22/18 15 1 T1 3569615 1 A4 13/22/18 16 1 T1 3569616 1 A5 13/22/18d1 ! 7 1 T1 3569617 1 ATA 13/22/187 18 1 T1 3569618 1 ATB 13/22/181 19 1 T1 3569619 1 ATC 13/22/181 110 1 T1 35696201 BHA 13/22/181 Ill I T1 35696211 G RA 13/22/181 112 IT13569622IJ2 13/22/18 113 T13569623JJ4 13/22/18 114 IT13569624IJ6 13/22/181 115 IT13569625IJ8 13/22/18 116 IT135696261JA8 13/22/18 117 1 T1 3569627 1 KJ8 13/22/181 The truss drawing(s) referenced above hav, e been prepared by MiTek USA, Inc. under my direct supervision based on the parameters provided by Chambers Truss. Truss Design Engineer's Name: Finn�l Walter My license renewal date for the state of Florida is February 28, 2019. i IMPORTANT NOTE: The seal on these truss component designs is a certification that the engineer named is licensed in the jurisdictidn(s) identified and that the designs comply with ANSI/TPI 1. These designs arel based upon parameters shown (e.g., loads, supports, dimensions, shapes an'd design codes), which were given to MiTek. Any project specific information included is for MiTek's customers file reference purpose only, and was not taken into �ccount in the preparation of these designs. MiTek has not independently verified the applicability of the design parameters or the designs for any particular buildin6. E3efore use, the building designer should verify applicability of design parameters and 1properly incorporate these designs into the overall building design per ANSl/TP1 1, Chapter 2. jel't P %% E N 2 )9 13 -STATt OF 41 Z .0 0 00 A, 4 0 Fk N 1�6/0�A Vs 1944 0414 'it Milts%" Walter R Flrm PE No.22839 Mrrek USA, Inc. �L Cert 6634 6904 Parke East Blvd. Tampa FL 33610 Date: March 22,2018 Finn, Walter I of I 1-Job Truss Truss Ty City Ply CARLTON 299 TI 3569611 M 11412 A SPEC,AL�e 1 1 1 1 Job Reference (optional) Chambers Truss, Inc., Fort Pierce, FL 8.130 s Mar 112018 MiTek Industries, Inc. Thu Mar 22 09:07:50 2018 Page I ID:kFvnsnOwY4l9ZhO-nM3lc6ylJgg-Kxmhf24KxO8wioTmEHbuMgbSn-fsl?A78qtMOJZYQn7 6-6-0 9-10-01 13-8�O 19_ _�_o 8 1 36-0-0 5-3 L2 "101 R-6-0 _1)-4-0' 3.10110 �9 44 59-3 i 7-2-12 4.00 [1-2 23 Cr. 2 6 3x6 6X8 3X6 \\ 3 4 24 16 3x4 4x5 256 is 6X8 U6 = 4x5 6 7 14 4x4 — 2. 0 0 r1_2 5x12 MT18HS 26 27 8 3x4 =5�� 9 13 12 7x8 MT18HS � 3x4 zz Scale = 1:63.0 4x10 zz -t 9-10-0 13-J-0 9-53 15 �4�--50 �6-2-00 36-0-0 9-10-0 3-10-0 1 9 5_0_1 1 _8_ 9-10-0 Plate Offsets (X,Y)-- [2:0-0-2,Edqel,[4:0-5-4,0-2-81,[6:0-3-0,Edqel,[8:0-9-0,0-2-8l,f10:0-2-10,Edgel,[15:0-1-12,0-2-121 LOADING (psf) SPACING- 2-0-0 cSI. DEFL. in (loc) I/defl Ud PLATES GRIP TCLL 20.0 Plate Grip DOL 1.25 TC 0.94 Vert(LL) -0.73 13-14 >595 360 MT20 244/190 TCDL 7.0 Lumber DOL 1.25 BC 0.94 Vert(CT) -1.34 13-14 >321 240 MT18HS 244/190 BCLIL 0.0 Rep Stress Incr YES WB 0.91 Horz(CT) 0.45 10 n1a n/a BCDL 10.0 Code FBC2017fTP12014 Matrix ­MS Wind(LL) 1.01 13-14 >428 240 Weight: 161 lb FT 20% LUMBER- BRACING- TOPCHORD 2x4 SP M 30 -Except* TOPCHORD Structural wood sheathing directly applied. 6-8: 2x4 SP M 31 BOTCHORD Rigid ceiling directly applied or 2-2-0 oc bracing. BOTCHORD 2X4 SP M 30 WEBS 2x4 SP No.3 REACTIONS. (lb/size) 2=1386/0-8-0, 10=1386/0-8-0 Max Horz 2=-1 19(LC 10) Max Uplift 2=-846(LC 12), 10=-846(LC 12) FORGES. (lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOPCHORD 2-3=-333812212, 3-4=-3134/2132, 4-5�3441 2388, 5-7�5141/3470, 7-8=-6766/4392, 8-9=-5629/3608, 9-1 O�5945/3856 BOTCHORD 2-16=-1 989/3129, 15-16=-1 777/2918, 14-15= -217713455, 13-14=-3307/5216, 12-13=-3301/5421, 10-12=-3593/5659 WEBS 3-16=-5271480, 4-16=-413/669, 4-15=-535/7E5, 5-15=-975f733, 5-14=-1 19811876, 7-14=-851/667, 7-13=-962/1695, 8-13=-1260i1909, 8-12=-45/349, 9-12=-319/328 NOTES- 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-10; Vult=165mph (3-second gust) Vasd=1281fnph; TCDL--4.2psf; BCDL=3.Opst; h=12ft; B=59ft; L=36ft; eave=5ft; Cat. 11; Exp C; Encl., GCpi=0.18; MWFRS (directional) and C-C xterior(2) -1 -0-0 to 2-7-3, Interior(l) 2-7-3 to 37-0-0 zone; C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) Provide adequate drainage to prevent water poncling. 4) All plates are MT20 plates unless otherwise indicated. 5) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 6) * This truss has been designed for a live load of 20.Opsf on the bottom chord In all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 1 7) Bearing at joint(s) 10 considers parallel to grain value using !ANSVTPI I angle to grain formula. Building designer should verify capacity of bearing surface. I '3) Provide mechanical connection (by others) of truss to bearinig plate capable of withstanding 100 lb uplift at joint(s) except at=1b) 2=846,10=846. Walter P. Finn PE No.22839 MiTek USA, Inc. FL Carl 6634 6904 Parke East Blvd. Tampa FL 33610 Date: March 22,2018 WARNING - Verify design parameters and READ NOTES ON THIS AN D INCLUDED MITEK REFERANCE PAGE Mll-7473 rov. 1010312015 BEFORE USE. Design valid for use only with MITek0 connectors. This design Is bas�d only upon parameters shown, and Is for an Individual building component, not a truss system. Before use, the building designer must verify the apolicability of design parameters and properly Incorporate this design Into the overall building design. Bracing Indicated Is to prevent buckling of IndivIdbal truss web and/or chord members only. Addil(onal temporary and permanent bracing MiTew Is always required for stability and to prevent collapse with possibld personal Injury and property damage. For general guidance regarding the tab 10 lion, storage, delivery. erection and bracing of trusses and l6s systems, seeANSI/IPI I Qualfty Criteria, DSB-89 and 8CS1 Building Component r Co 6904 Parke East Blvd. Safety Information available from Truss Plate Institute. 218 N. Lee Sirbet, Suite 312, Alexandria, VA 22314. Tampa, I'L 33610 J.0 b Trus Truss Typ6 Qly Ply CA LTON 299 TI 3569612 M1 1412 Al SPECIAL Job Refer �narrll)ers I russ, Inc., r-UR Vle[GL, r-L 8-6-0 ID:kFvnsnOwY4[gZhO—nM3lc6ylJ9g-o8K3sN5yiJGnKy2yo?67VUifO?3mYOGNUcwYlzYQn6 24-9-0 28-9-4 36-0.0 �7-O-Q Scale = 1:63.0 oXo 3X8 5X6 4.00 F1-2 4 22 5 23 6 3X4 3X4 7 21 24 , 01 2 13 9 �� I i Wj 12 3X4 11 7x8 MT18HS 10 3X4 11 1 Cb 6 6 14 13 3x6 3X4 SX6 2.00 FI-2 4x10 zz 13-8-0 18-7- 246-0 �8-9-4 36-0-0 8-�—O 5-2-0 411 .4 �_g 12 4-3-4 7-2 -12 - Plate Offsets (X,Y)-- [2:0-0-2, Edge], [8:0-2-1 0,Edgel, [13:0-3-0,0-3-01 LOADING (psf) SPACING- 2-0-0 CS1. DEFL. in (loc) Ildefl Ud PLATES GRIP TCLL 20.0 Plate Grip DOL 1.25 TC 0.61 Vert(LL) -0.58 11 >749 360 MT20 244/190 TCDL 7.0 Lumber DOL 1.25 BC 0.95 Vert(CT) -1.0711-12 >402 240 MT18HS 2441190 BCLL 0.0 Rep Stress Incr YES WB 0.55 Horz(CT) 0.40 8 n/a n/a BCDL 10.0 Code FBC2017/TP[2014 Matdx-MS Wind(LL) 0.80 11 >541 240 Weight: 163 lb FT = 20% LUMBER - TOP CHORD 2X4 SP M 30 BOTCHORD 2x4SPM30 WEBS 2x4 SP No.3 REACTIONS. (lb/sIze) 2=1386/0-8-0, 8=1386/0-8-0 Max Horz 2=-1 41 (1-13 10) Max Uplift 2=-846(LC 12), 8=-846(LC 12) FORCES. (lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or TOPCHORD 2-3=-3356/2159, 3-4=-3358/2292, 4-5=-2798/ 7-8=-5962/3751 BOTCHORD 2-14=-1935/3141, 13-14=-1610/2666,12-13=- 10-11 �3499/5680, 8-1 0=-3492t5669 WEBS 3-14=-4041391, 4-14=-507/777, 4-13=-151/40! 6-11 =-849/1449, 7-11 =-641/463 BRACING- TOPCHORD BOTCHORD WEBS ,ss except when shown. 921, 5-6�4830/3137, 6-7=-535313403, 11-12=-2400/3924, 5-13=-1376/890,5-11�557/1048, Structural wood sheathing directly applied or 2-7-2 oc pudins. Rigid ceiling directly applied or 2-2-0 oc bracing. 1 Row at midpt 5-13 NOTES- 1) Unbalanced root live loads have been considered for this de'llign. 2) Wind: ASCE 7-10; Vult=165mph (3-second gust) Vasd=128mph; TCDL--4.2psf; BCDL=3.Opsf; h=12ft; B=59ft; L=36ft; eave=5ft; Cat. 11; Exp C; Encl., GCpi=0.18; MWFRS (directional) and C-C Exterior(2) -1-0-0 to 2-7-3, Interior(l) 2-7-3 to 37-0-0 zone;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) Provide adequate drainage to prevent water ponding. 4) All plates are MT20 plates unless otherwise indicated. 5) This truss has been designed for a 10.0 psf bottom chord IIv,e load nonconcurrent with any other live loads. 6) * This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 1 7) Bearing at joint(s) 8 considers parallel to grain value using ANSI/TPI I angle to grain formula. Building designer should verify capacity of bearing surface. 1 8) Provide mechanical connection (by others) of truss to bead g plate capable of withstanding 100 lb uplift at joint(s) except Qt=lb) 2=846,8=846. i Walter P. Finn PE No.22839 MiTek USA, Inc. FL Cert 6634 6904 Parke East Blvd. Tampa Fl. 33610 Date: March 22,2018 WARNING - Verify design parameters and RE4D NOTES ON THIS AND INCLUDED MITEKREFERANCE PAGE Mll-7473 rev. 1010312015 BEFORE USE Design valld for use onlywith MITek6 connectors. This design Is bo d only upon parameters shown, and Is for an Individual building component not a truss system. Before use, the building designer mus )7]lcabllity of design parameters and properly Incorporate this design Into the overall building design. Bracing Indicated Is to prevent buckling of Individbal truss web and/or chord members only, Additional temporary and permanent bracing Mel( Is always required for stability and to prevent collapse with possible personal Injury and property damage. For general guidance regarding the fabrication. storage, dellvery� erection and bracing of trusses and truss�systems, seeANSI/TPI I Quality Criteria, DSB-89 and BCS1 Building Component 6904 Parke East Blvd. Safety Information available from Truss Plate Institute. 218 N. Lee Slipet, Suite 312, Mexandria, VA 22314. Tampa, FL 33610 job Truss Truss Typ b City Ply CARLTON 299 TI 3569613 M1 1412 A2 SPECIAL 1 � Job Reference (optional) Chambers Truss, Inc., Fort Pierce, FL 8 130 s Mar 11 2018 MiTek Industries, Inc. Thu Mar 22 09:07:52 2018 Page I I ID:kFvnsnOwY41'gZhCLnM3lc6ylJgg-GKuR4j6bTdOey6dgMidMR5gtzoLPVycQcBMT4BzYQn5 8-6-0 13-10-0 1 �2�O 24-6-0 28-9-4 36-0-0 7-0 M-00 8-6-0 5-4-0 '-o 2-4-0 4-3-4 7-2-12 1-0-4 i 14--N— L4 Scale = 1:63.0 5X6 = 5x6 3x4 4.00F1-2 4 5 6 4x6 zzz 7 3x4 3M 3 8 23 22 12 13 11 9 107 91 3XIO 3x4 11 1 6 7x8 MT1 8HS 4x10 z-- 2.00FI-2 22-2-0 LOADING (pst) TOLL 20.0 TCDL 7.0 BOLL 0.0 BCDL 10.0 SPACING- 2-0-0 Plate Grip DOL 1.25 Lumber DOL 1.25 Rep Stress Incr YES Code FBC2017ITP12014 CS1. TO 0.58 BC 0.94 WB 0.72 Matrix -MS DEFL. Vert(LL) Vert(CT) Horz(CT) Wind(LI-) in (Joe) I/clef! Ud -0.55 11-12 >779 360 -1.03 11-12 >419 240 0.39 9 nfa n/a 0.7711-12 >564 240 PLATES MT20 MT18HS Weight: 167 lb GRIP 244/190 244/190 FT = 20% LIUMBER- BRACING - TOP CHORD 2x4 SP M 30 TOPCHORD Structural wood sheathing directly applied or 2-7-0 oc puffins. BOTCHORD 2x4 SP M 30 BOTCHORD Rigid ceiling directly applied or 2-2-0 oc bracing. WEBS 2x4 SP No.3 REACTIONS. (lb/size) 2=1386/0-8-0, 9=1386/0-8-0 Max Horz 2=1 63(LC 11) Max Uplift 2=-846(LC 12), 9=-846(LC 12) FORCES. (lb) - Max. Comp./Max. Ten. - All forces 250 (lb) o�, less except when shown. TOP CHORD 2-3�3359121129, 3-4=-2661/1761, 4-5=-2445 1690, 5-6�3533/2289, 6-7=-3698/2365, 7-8=-5359/3351, 8-9=-5963/3683 BOTCHORD 2-15=-1909/3146,14-15=-190913146,13-14='-1826/3099,12-13=-3016/5125, 11-12=-3433/5679, 9-1 1=-3426/5(369 1 WEBS 3-15=0/295, 3-14=-807/566, 4-14=-354/620 5-14=-916/581, 5-13=-261/668, ' 6-13=-588/1003, 7-13=-2219/1408, 7-12=-1 1137/1893, B-12=-628/443 NOTES- I 1) Unbalanced roof live loads have been considered for this d I esign. 2) Wind: ASCE 7-10; Vult=165mph (3-second gust) Vasd=12 mph; TCDL--4.2psf; BCDL=3.Opsf; h=12ft; B--59ft; L=36ft; eave=51t; Cat. 11; Exp C; Encl., GCpi=0.18; MWFRS (directional) and C-C Extedor(2) -1-0-0 to 2-7-3, Interior(l) 2-7-3 to 37-0-0 zone;C-C for members and forces & MWIFFIS for reactions shown; Lumt er DOL=1.60 plate grip DOL=1.60 3) Provide adequate drainage to prevent water ponding. 4) All plates are MT20 plates unless otherwise indicated. 5) This truss has been designed for a 10.0 psf bottom chord If I ve load nonconcurrent with any other live loads. 6) * This truss has been designed for a live load of 20.Opsf on'the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide Will fit between the bottom chord and any other members. 1 7) Bearing at joint(s) 9 considers parallel to grain value using ANSI/TPI I angle to grain formula. Building designer should verify capacity of bearing surface. 1 8) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) except at=lb) 2=846,9=846. 1 Walter P. Finn PE No.22839 MjTek USA, Inc. FL Cert 6634 6904 Parke East Blvd. Tampa Fl. 33610 Date: March 22,2018 WARNING- Verify design parameters and READ NOTES ON THIS Al ND INCLUDED MITEK REFERANCE PAGE Mll-7473 rev. 1010312015 BEFORE USE. Design valid for use only with MITek6 connectors. This design Is based only upon parameters shown, and Is for an Individual building component, not a truss system. More use, the building designer Must verify the ol�pllcablllty of design parameters and properly Incorporate this design Into the overall Wilding design. Bracing Indicated Is to buckling of Individual truss web and/or chord members only. Additional temporary and permanent bracing MOW prevent Is always required for stability and to prevent collapse with possl8le personal injury and property damage. For general guidance regarding the fabrication, storage. delivery. erection and bracing of trusses and truss systems, seeANSI/TPI I Quality Criteria, DSB-89 and BCS1 Building Component 6904 Parke East Blvd. Safety Information available from Truss Plate Institute, 218 N. Lee �Ireet, Suite 312, Aexandda, VA 22314. Tampa, FL 33610 ,Ipb Trus I Truss Type A City Ply CARLTON 299 T13569614 M 11412 A3 SPECIAL Job Refer Phambers Truss, Inc., Fort Pierce, FL 8-6-0 6J 30 s Mar 112018 rvii i ur, indusirres, mu. i hu Iviar 22 09:0f:54 20 lu Mue I ID:kFvnsnOwY419ZhO—nM3lc6ylJ9g-CiOCVP7r—EfLBPnXT7fqXWIDjcOvzsni3Srag4zYQn3 4�6-0 4 1 36-0-0 L8 9- 0 T 8-6-0 �2-00 T _0 U4 7 -2-12 Scale: 3/16'=I' 4.00112 5x6 5x6 4 5 5x6 5XB 6 M WB_- 3x4 7 8 22 23 `0 2 12 9 6 10 ;� I 13 4x8 11 7x8 MT18HS 3x4 11 19 0 - 6 L_— �� 15 14 3x4 11 M = _2 4x10 :z 3X5 2.00 F1 28-9-4 LOADING (pso TCLIL 20.0 TCDL 7.0 BCLL 0.0 BCDL 10.0 SPACING- 2-0-0 Plate Grip DOL 1.25 Lumber DOL 1.25 Rep Stress Incr YES Code FBC2017/TP12014 CS1. TC 0.56 BC 0.94 W B 0.74 Matflx-MS DEFL. Vert(LL) Vert(CT) Horz(CT) Wind(LL) in (loc) Well Ud -0.57 11-12 >761 360 -1.05 11-12 >41 0 240 0.40 9 n/a n/a 0.78 11-12 >551 240 PLATES MT20 MT18HS Weight: 167 lb GRIP 244/190 244/190 FT = 20% LUMBER- BRACING- TOPCHORD 2x4 SP M 30 TOPCHORD Structural wood sheathing directly applied or 2-6-15 oc purlins. BOTCHORD 2x4 SP M 30 BOTCHORD Rigid ceiling directly applied or 2-2-0 oc bracing. WEBS 2x4 SP No.3 WEBS 1 Row at midpt 6-13 OTHERS 2x4 SP No.3 REACTIONS. (lb/size) 2=1386/0-8-0,9=1386/0-8-0 Max Horz 2=185(LC 11) Max Uplift 2=-846(LC 12), 9=-846(LC 12) FORCES. (lb) - Max. Comp./Max. Ten. - All forces 250 (11)) or ess excep en shown. TOPCHORD 2-3�3371/2103, 3-4=-2633/1707, 4-5=-2803i 1850, 5-6=-2968/1899, 6-8=-5371/3290, B-9=-5960/3616 BOTCHORD 2-15=-1886/3159,14-15=-1 886/3153 ' 13-14=-1 34312432,12-13=-2958/5146, 11 -1 2=-3368/5675, 9-11 =-336215666 1 WEBS 3-15=0/306,3-14=-866/626, 4-13=-285/671, 5-13=-379[702, 6-13=-2706/1659, 6-12=-109411946, 8-12=-611/435 1 NOTES- 1) Unbalanced roof live loads have been considered for this clIgn. 2) Wind: ASCE 7-10; Vult=165mph (3-second gust) Vasd=128mph; TCDL=4.2psf; BCDL=3.Opsf; h=12ft; B=59ft; L=36ft; eave=5ft; Cat. 11; Exp C; Encl., GCpi=0.18; MWFRS (directional) and C-C Exterior(2) -1-0-0 to 2-7-3, Interior(l) 2-7-3 to 37-0-0 zone;C-C for members and forces & MWFRS; for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) Provide adequate drainage to prevent water ponding. 4) All plates are MT20 plates unless otherwise indicated. 5) This truss has been designed for a 1 . 0.0 psf bottom chord IIV,9 load nonconcurrent with any other live loads. 6) * This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. : 7) Bearing at joint(s) 9 considers parallel to grain value using ANSI/TPI 1 angle to grain formula. Building designer should verify capacity of bearing surface. 1 8) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) except at=lb) 2=846,9=846. Walter P. Finn PE No.22839 MiTek USA, Inc. Fl. Cart 6634 6904 Parke East Blvd. Tampa Fl. 33610 Date: March 22,2018 i AWARNING -Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEKREFERANCE PAGE Mll-7473 rev. 10103,2015 BEFORE USE. -- Design valid for use only with MITek0connectors. This design Is bas�d only upon parameters shown, and Is for on Individual building component, not Del' a tfUSSsyslem, Before use, the building designer must verity the ap6lIcablIlly of design parameters and properly Incorporate this design Into tile overall building design. Bracing Indicated Is to buckling of Individual fruss web and/or chord members only. Addillonal temporary and permanent bracing MiTek' prevent Is always required for stability and to prevent collapse with possibld personal injury and property damage. For general guidance regarding the fabrication. storage. delivery, erection and bracing of trusses and truss systems. seeANSI/TPI I Quality Criteria, DSB-89 and BCS1 Building Component Safety Information available from Truss Plate Institute, 218 N. Lee StrPet, Suite 312. Alexandria. VA 22314. 6904 Parke East Blvd. Tampa, FL 33610 Job Truss Truss yp e Qty Ply CARITON 299 I T1 3569616 MI 1412 'A4 SPECIAII Job Reference (optional) �namDers i russ, inc., r-OR rietCe, M 8-6-0 23 6 3x5 8-6-0 4-4-0 4.00 F1 2 5X6 6 3x4 M 5 24 3x4 3 ID:kFvnsn����IgZhO—nM3lc6�l���gvaail8TIYnCpZMkl'rB33jiNy?MCiFpsl6a7hWzYQn2 24-6-0 ?1-14 36-0-0 7-0- 6-6-0 7-2-12 _0__ 16 '15 3x12 ::=. 3x4 11 5X8 2.00F1_2 25 SX6 Zz: 5x6 WBZZZ 8 3x4 Z�' 9 Srale: 3/16"=I' ��26 � 3 1 0� d' 1 1 1 — 7� MT1 8HS �= 1 211 1 11� �3x4 1 6 WO Z: LOADING (psf) SPACING- 2-0-0 CSI. DEFL. in (loc) Vdefl L/d PLATES GRIP TCLL 20.0 Plate Grip DOL 1.25 TC 0.60 Vert(LL) -0.61 13 >709 360 MT20 244/190 TCDL 7.0 Lumber DOL 1.25 BC 0.93 Vert(CT) -1.13 13 >383 240 MT18HS 244/190 BCLL 0.0 Rep Stress Incr YES WB 0.95 Horz(CT) 0.42 10 nta n/a BCDL 10.0 Code FBC2017frPI2014 Matrix -MS Wind(LL) 0.84 13 >513 240 Weight: 170 lb FT = 20% LIUMBER- BRACING - TOP CHORD 2x4 SP M 30 TOPCHORD Structural wood sheathing directly applied or 2-6-11 oc purfins. BOTCHORD 2x4 SP M 30 BOTCHORD Rigid ceiling directly applied or 2-2-0 oc bracing. WEBS 2x4 SP No.3 WEBS 1 Row at midpt 7-14 OTHERS 2x4 SP No.3 REACTIONS. (lb/size) 2=1386/0-8-0, 10=1386/0-8-0 Max Harz 2=-207(LC 10) Max Uplift 2=-846(LC 12), 1 0=-846(LC 12) FORCES. (lb) -Max. Comp./Max. Ten. -All forces 250 Qb) or less except when shown. TOPCHORD 2-3=-3361/2183, 3-5=-2660/1831, 5-6=-2458/,1735 6 7— 2481/1 19, 7-9=-5407/3513, 9-10=-5950/3765 1 BOTCHORD 2-16=-1931/3146,15-16=-1931/31146,14-l5—Ll489/2515,13-14=-3185/519l, 12-13=-3510/5666, 10-12=-3504/5656 1 WEBS 3-16=0/315, 3-15=-799/546, 5-14=-344/260, 6-14=-731/1202, 7-14=-312012048, 7-13=-1 13011972, 9-13=-559/376 NOTES- 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-10; Vult=l 65mph (3-second gust) Vasd=1 28.mph; TCDL=4.2psf; BCDL=3.Opsf; h=1 2ft; B=59ft; L=36ft; eave=5ft; Cat. 11; Exp C; Encl., GCpI=0. 18; MW FRS (directional) and C-C Exterior(2) -1 -0-0 to 2-7-3, Interior(l) 2-7-3 to 1 B-0-0, Exterior(2) 18-0-0 to 21-7-3 zone;C-0 for members and forces & IvIWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) All plates are MT20 plates unless otherwise indicated. 1 4) This truss has been designed for a 10.0 psf botto� chord live load nonconcurrent with any other live loads. 5) * This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide Will fit between the bottom chord and any other members. 1 6) Bearing at joint(s) 10 considers parallel to grain value using IANSVTPI 1 angle to grain formula. Building designer should verify capacity of bearing surface. 1 7) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) except at=lb) 2=846,10=846. Walter P. Finn PE No.22839 MiTek USA, Inc. FL Cert 6634 6904 Parke East Blvd. Tampa FL 33610 Date: March 22,2018 AwARAft- -verify design parameter. and READ NOTES ON THIS AND INCLUDED MITEK REFERANCE PAGE Mll-7473 rev. 1010312015 BEFORE USE. Design valid for use only wilh MiTeW connectors. This design Is basbd only upon parameters shown, and Is for on Individual building component, not a truss system. Before use, the building designer must verify the api$11cability of design parameters and property Incorporate this design Into the overall building design. Bracing Indicated Is to prevent buckling of lndlvId truss web and/or chord members only. Additional temporary and permanent bracing MiTeW ly,al Is always required for slablllty and to prevent collar I personal Injury and property damage. For general guidance regarding the fabrication, storage. delivery, erection and bracing of trusses and truss systems. seeANSI/TPI I QUGIIIY Criteria. DSB-89 and BCSI Building Component 6904 Parke East Blvd. Safety Information available from Truss Plate Institute, 218 N. Lee SiJeet. Suite 312, AJ exandda, VA 22314. Tampa, FL 33610 4b Tru - s Truss yre ty Ply CARLTON 299 T13569616 M1 1412 A5 SPECIAL r7 1 Job Referep - f—fi-11 L,namuei5 1 lub5' Inc., rUIL r­M[U�, FU 2 0 18 N 5-2-0 4t_ 1 4.00F1_2 5X6 1 6 3X4 t-; 3X6 5 24 SX4 �� 4 3 -7� �1 23 16 3x5 3A ID:kFvnsnOwY4[gZhO-nM3lc6ylJgg-958yw5g5Wsv3RjwwbYilcxrYhPiRRi-?XmKhDzzYanI 24-6-0 '-4 1 36-0-0 7-0- 6-6-0 I_N_ 7-2-12 0- 14 15 4XIO 5X8 2.00 FIT 18-0-0 25 5X6 -- 5X6 WI1 8 3x4 zz� 9 Scale = 1:61.9 13 �26� 10 1 1 41 'X, I;z MTJ 1H 211 lch 6 WO Z7 LOADING (psf) SPACING- 2-0-0 CS1. DEFL. in, (loc) I/defl Ud PLATES GRIP TCLL 20.0 Plate Grip DOL 1.25 TC 0.60 Vert(LL) -0.61 13 >709 360 MT20 244/190 TCDL 7.0 Lumber DOL 1.25 BC 0.93 Vert(CT) -1.13 13 >383 240 MT18HS 244/190 BCLL 0.0 Rep Stress Incir YES WB 0.95 Horz(CT) 0.42 10 - n1a n/a BCDL 10.0 Code FBC2017/TPI2014 Matflx-MS Wind(LL) 0.84 13 >513 240 Weight: 170 lb FT = 20% LUMBER- BRACING - TOP CHORD 2X4 SP M 30 TOPCHORD Structural wood sheathing directly applied or 2-6-11 oc pudins. BOTCHORD 2X4 SP M 30 BOTCHORD Rigid ceiling directly applied or 2-2-0 oc bracing. WEBS 2x4 SP No.3 WEBS 1 Row at midpt 7-14 OTHERS 2x4 SP No.3 REACTIONS. (lb/size) 2=1386/0-8-0, 10=1386/0-8-0 Max Harz 2=-208(LC 10) Max Uplift 2=-846(LC 12), 1 0=-846(LC 12) FORCES. (lb) -Max. Comp./Max. Ten. -All forces 250 (lb) or, less except when shown. TOPCHORD 2-3=-3361/2183, 3-5=-2660/1831, 5-6=-245 1713, 7-9=-5407/3513, 9-1 0=-5950/3764 BOTCHORD 2-16=-1 931/3146, 16-16=-1 931/3146, 14-1 6=-1 489/2515, 13-14=-3184/5190, 12-13=-3510/5666, 10-12=-3504/5656 1 WEBS 3-16=0/315, 3-15=-7991546, 5-14=-355/272, 6-14=-743/1219, 7-14=-3134/2058, 7-13=-1 13011972, 9-13=-560/375 1 NOTES- 1 ) Unbalanced roof live loads have been considered for this d6sign. 2) Wind: ASCE 7-10; Vult=165mph (3-second gust) Vasd=128mph; TCDL--4.2psf; BCDL=3.Opsf; h=12ft; B=59ft; L=36ft; eave=5ft; Cat. 11; Exp C; Encl., GCpl=0.18; MWFRS (directional) and C-C Exlerior(2) -1 -0-0 to 2-7-3, Interior(l) 2-7-3 to 18-0-0, Extedor(2) 18-0-0 to 21-7-3 zone;C-C for members and forces & MWFRS for real ctions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) All plates are MT20 plates unless otherwise indicated. 4) This truss has been designed for a 10.0 psf bottom.chord li�e load nonconcurrent with any other live loads. -6-0 tall by 2-0-0 wide 5) * This truss has been designed for a live load of 20 Opsf on1the bottom chord in all areas where a rectangle 3 will fit between the bottom chord and any other members. 1 6) Bearing at joint(s) 10 considers parallel to grain value using ANSVTPI I angle to grain formula. Building designer should verify capacity of bearing surface. i 7) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at Joint(s) except at=lb) 2=846, 1 0=846� Walter P. Finn PE No.22839 Mi rok USA, Inc.. FL Cort 6634 6904 Parke East Blvd. Tampa FL 33610 Date: March 22,2018 ,& WARNING - Verify design parameters and READ NOTES ON THIS A NO INCLUDED MITEK REFERANCE PAGE 11117-7473 rev. 1010312015 BEFORE USE. Design valid for use only with MiTek8 connectors. This design Is b&ed only upon parameters shown. and Is for an Individual building component, not sot a truss system. Before use. the building designer must verify the aliplIcablilty of design parameters and properly incorporate this design Into the overall building design. Bracing Indicated Is to buckling of Individual truss web and/or chord members only. Additional temporary and permanent bracing MiTeW prevent Is always required for stability and to prevent collapse with possible personal Injury and property damage. For general guidance regarding the 6904 Parke East Blvd. fabrication, storage, delivery. erection and bracing of trusses and truss systems, seeANSI/TPI I Quality Criteria, DSB-89 and BCS1 BuIlding Component Safety Information available from Truss Plate Institute. 218 N. Lee S�,reet, Suite 312, Alexandria, VA 22314. Tampa, FL 33610 �ob Truss Truss Type cily P y ARLTON 299 TI 3569617 M1 1412 ATA commo 7 1 Job Reference (optional) parnoers I russ, Inc., I--0r1 l-lerCe, t-L 4.00F1-2 3x4 11 26 3x6 5 25 3x4 5:� 4 3 24_�� u) 6 17 16 1_ 4X6 = 3X8 3X 3X4 8-1 5x6 6 .. . . .. . — 1--l—, .1 — I — — -- . - . ­ . ID:kFvnsnOwY4l9ZhO-nM3lc6ylJgg-dHhK7RAjH9lw2tV69FDXBBNkPp6jAEjOI03EmPzYQnO 11- 4 27-10-15 36-0-0 Q7-O-Q 4-M4 5-9-1 8-1-1 4-0-d 3x4 11 27287 3x6 8 3x4 Z--- 9 Scale = 1:61.0 29 10 30 31 14 13 12 6 3x8 = 4x6 3x4 11 3x8 22-1-14 LOADING (psf) SPACING- 2-0-0 CS1. DEFL. in (loc) I/defl Ud PLATES GRIP TCLL 20.0 Plate Grip DOL 1.25 TC 0.53 Vert(LL) -0.28 14-15 >999 360 MT20 244/190 TCDL 7.0 Lumber DOL 1.25 BC 0.67 Vert(CT) -0.59 14-15 >730 240 BCLL 0.0 Rep Stress Incr YES WB 0.60 Horz(CT) 0.14 10 n1a n/a BCDL 10.0 Code FBC2017fTP12014 Matrix -MS Wind(LL) 0.34 14-15 >999 240 Weight: 172 lb IFT = 20% LIUMBER- BRACING - TOP CHORD 2x4 SP M 30 TOPCHORD Structural wood sheathing directly applied or 3-2-15 oc puffins. BOTCHORD 2x4 SP M 30 BOTCHORD Rigid ceiling directly applied or 5-2-0 oc bracing. WEBS 20 SP No.3 REACTIONS. (lb/size) 2=143610-8-0, 10=143610-8-0 Max Horz 2=-208(LC 10) Max Uplift 2=-796(LC 12), 1 0=-796(LC 12) FORCES. (lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOPCHORD 2-3�3544/2053, 3-5=-2824/1651, 5-6=-2817,'1766, 6-7=-2817/1766, 7-9=-2824/1651, 9-10=-3544/2053 BOTCHORD 2-17=-181213323,15-17=-1812/3�323,14-151-997/2104,12-14=-1826/3323, 10-12=-1826/3323 1 WEBS 6-14=-569/1002, 7-14=-299/279,9-14=-783/581, 9-12=0/27116-15=-569/1002, 5-15=-300/279,3-15=-782/581, 3-17=0/271 1 NOTES- 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-10; Vult=165mph (3-second gust) Vasd=128 I mph; TCDL--4.2psf; BCDL=3.Opsf; h=12ft; B=59ft; L=36ft; eave=5ft; Cat. 11; Exp C; Encl., GCpl=0.18; MWFRS (directional) and C-C Exterior(2) -1-0-0 to 2-7-3, Interior(l) 2-7-3 to 18-0-0, Exterior(2) 18-0-0 to 21-7-3 zone;C-C for members and forces & MW`FRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) 1 00.01b AC unit load placed on the top chord, 18-0-0 from left end, supported at two points, 6-0-0 apart. 4) This truss has been designed for a 10.0 psf bottom chord lj�e load nonconcurrent with any other live loads. 5) * This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members, with BCDL = 1 O.Opsf. 6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) except at=lb) 2=796,10=796. Walter P. Finn PE No.22839 Mi rek USA, Inc. Fl. Gert 6634 69D4 Parke East Blvd. Tampa Fl. 33610 Date: March 22,2018 I ,&WARNING Verily design parameters and READ N07-ES ON THIS AND INCLUDED MffEKREFERANCE PAGE MU-7473 rev. 10103,2015 BEFORE USE. -- Design valid for use only with MiTekO connectors. This design Is bas , ed only upon parameters shown. and Is for an Individual building component not Dal' a truss system. Before LW, the building designer must verify the apblicability of design parameters and properly Incorporate this design Into the overall building design. Bracing Indicated Is to buckling of Individual truss web and/or chord members only. Additional temporary and permanent bracing Mffek' prevent Is always required for stability and to prevent collapse with posslbl6 fabrication, storage, delivery, erection and bracing of trusses and personal Injury and property damage. For general guidance regarding the truss systems. seeANSI/TPI 1 Quality Criteria, DSB-89 and BCSI Building Component 6904 Parke East Blvd. Safety Information avallable from Truss Plate institute, 218 N. Lee Street. Suite 312, Alexandria. VA 22314. Tampa, FL 33610 �ob Trus Truss yP9 city Ply CARLTON 99 T135696i8 M 11412 ATB COMMON Job Reference (optional) ?namver5 i russ, iric., ru[L rL I I 11-0-0 8-1-1 13-10-2, NEI 4.00 F1_2 3x4 [I 26 27 3x6 3X6 26- 3x4 4 3 C�. 25 2 T 6 L-�E� 17 16 E� 31 is 15 3x5 3X4 11 3X6 6x8 = 1 LOADING (psf]i SPACING- 2-0-0 CS1. TCLL 20.0 Plate Grip DOL 1.25 TC 0.37 TCDL 7.0 Lumber DOL 1.25 BC 0.40 BCLL 0.0 Rep Stress Incr YES WB 0.68 BCDL 10.0 Code FBC2017/TP12014 Matrix -MS LUIMBER- TOP CHORD 2X4 SP M 30 BOT CHORD 2X4 SP M 30 WEBS 2x4 SP No.3 REACTIONS. All bearings 0-8-0 Q. I ov o ivill 1 1 av" —I", ID:kFvnsnOwY4l9ZhO-nM3lc6ylJgg-6UFjKnBL2T9ngl4lizkmhMwyeDWlvgpi-4pnirzYQn? 22-1-14 2 Z� �01 5 36-0-0 -0 4-1-14 i 9_1 8-1-1 Vo__0? 5x6 6 3x4 11 297 3x6 8 3x4 Z--- 9 SGale = 1:60.9 101 Ich 32 14 13 12 6 6x8 3x6 3x4 11 36 DEFL. in (loc) I/defl Lid PLATES GRIP Vert(LL) -0.10 18-21 >999 360 MT20 244/190 Vert(CT) -0.22 18-21 >844 240 Horz(CT) 0.02 15 n1a n1a Wind(ILL) 0.15 18-21 >999 240 Weight: 172 lb FT = 20% BRACING- TOPCHORD Structural wood sheathing directly applied or 6-0-0 oc puffins. BOTCHORD Rigid ceiling directly applied or 6-0-0 oc bracing. WEBS 1 Row at midpl: 6-14 Qb) - Max Horz 2=-208(LC 10) 1 MaxUplift All uplift 100 lb or less atjoint(s) 15 except 2=-433(LC 12),14=-866(LC 12), 10=-240(LC 12) MaxGrav All reactions 250 lb or less atjoint(s) except 2=687(LC 21), 14=1635(LC 1), 10=399(LC 22), 15=349(LC 17) 1 FORCES. (lb) -Max. Comp./Max. Ten. -All forces 250 (lb) or less except when shown. TOPCHORD 2-3=-1 239f757, 3-5=-437/333, 5-6=-4321448, 6-7=-2721773, 7-9=-3761778, 9-1 0=-334/220 1 BOTCHORD 2-1 8=-58711178, 16-1 8=-587/1178, 12-14=11 88/281, 10-12=-1 88/281 WEBS 6-14=-1096/683, 7-14=-303/281, 9-14=-8531614,9-12=-13/307, 6-16-5011665, 5-16=-302/279, 3-16=-890/616, 3-18=-1 6/332 NOTES- 1 ) Unbalanced roof live loads have been considered for this Pesign. 2) Wind: ASCE 7-10; Vult=165mph (3-second gust) Vasd=12.8mph; TCDL--4.2psf; BCDL=3.Opsf; h=12ft; B=59ft; L=36ft; eave=5ft; Cat. 11; Exp C; Encl., GCpi=0.18; MWFRS (directional) and C-0 Extedor(2) -1-0-0 to 2-7-3, Interlor(l) 2-7-3 to 18-0-0, Exterfor(2) 18-0-0 to 21-7-3 zone;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=11.60 plate grip DOL=1.60 3) 100.Olb AC unit load placed on the top chord, 18-0-0 from, left end, supported at two points, 6-0-0 apart. 4) This truss has been designed for a 10.0 psf'bottom chord'live load nonconcurrent with any other live loads. 5) * This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members: with BCDL = 10.Opsf. 6) Provide mechanical connection (by others) of truss to be6ring plate capable of withstanding 100 lb uplift at joint(s) 15 except at=lb) 2=433,14=866,10=240. Walter P. Finn PE No.22839 MiTek USA, Inc. Ft. Carl 6634 6904 Parke East Blvd. Tampa FL 33610 Date: March 22,2018 WARNING - Verify design parameters and RE40 MOTES ON THISI AND INCLUDED MITEK REFERAMCE PAGE M11-7473 rev. 1010312015 BEFORE USE. Design valid for use only with MITekS connectors. This design Is based only upon parameters shown, and Is for an Individual building component not a truss system. Before use, the buililding designer must verity Ih6 applicability of design parameters and properly Incorporate this design Into the overall bullding design. Bracing Indicated Is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing MiTele Is always required for stability and to prevent collapse with possible personal Injury and property damage. For general guidance regarding the fabrication, storage. delivery, erection and bracing of trusses dnd truss systems, seeANSI/TPI I Quality Criteria, DSB-89 and BCSI Building Component 6904 Parke East Blvd. Safety Information available from Truss Plate Institute, 218 N. Lde Street, Suite 312. Alexandra. VA 22314. Tampa, FL 33610 Job Trus Truss ype Q ty Ily CARLTON 299 T1 3669619 M1 1412 ATC COMMO� Job R f r ne (optional) �;nalnDel`S iruss, Inc., ron merce, r-L I . . . .. I .. — — .- -- --.- - — - . ID:kFvnsnOwY41�2�6_'n"M3lc6ylJgg-Zgp5Y7B-pnHelBfVGgF?EZT70dsXe73SDkYLqHzYQn_ 1�0;4 13-10-21 0 ��2.1_14 %719015 36-0-0 1 -1-1 VO-(Y 0 �11 Vo 5-9-1 1 4_1_14 8 2 6 3X5 = 25 4.00 FIT 5X6 6 3x4 11 3x4 11 "X" 2" 29 7 3x6 5 2627 28297 3x6 ZZ� 8 3x4 4 3x4 3 --:� 9 17 '-� 31 32 — 13 is 16 15 14 12 3x4 11 6x8 = 6xe = M 3A 11 I LOADING (pso SPACING- 2-0-0 CSI. DEFL. in (loc) I/def] Ud TCLL 20.0 Plate Grip DOL 1.25 TC 0.37 Vert(LL) -0.10 113-21 >999 360 TCDL 7.0 Lumber DOL 1 ' 25 BC 0.40 Vert(CT) -0.22 18-21 >844 240 BCLI- 0.0 Rep Stress Incr YES S WB 0.68 Horz(CT) 0.02 15 n1a n/a BCDL 10.0 Code FBC2017/TPI201 4�j Malrix-MS WInd(LI-) 0.15 18-21 >999 240 LUMBER - TOP CHORD 2X4 SP M 30 BOT CHORD 2X4 SP M 30 WEBS 2x4 SP No.3 REACTIONS. All bearings 0-8-0 except at=length) 14= (lb) - Max Harz 2=-208(LC 10) MaxUplift All uplift 100 lb or less atioinl Max Grav All reactions 250 lb or less at 15=349(LC 17) FORCES. (lb) - Max. Comp./Max. Ten. - All forces 250 ( TOPCHORD 2-3=-12391757, 3-5=-437/333, 5-6=-432 9-1 0=-334/220 BOTCHORD 2-1 8=-587/1178, 16-18=-587/1178, 12-1 WEBS 6-14=-1096/683, 7-14=-303/281, 9-14=- 5-16=-302/279, 3-16=-890/616, 3-1 8=-1 NOTES- 1) Unbalanced roof live loads have been considered for I 2) Wind: ASCE 7-10; Vult=165mph (3-second gust) Vasi 11; Exp C; Encl., GCpi=0.18; MWFRS (directional) and 21-7-3 zone;C-C for members and forces & MWFRS f 3) 1 00.01b AC unit load placed on the top chord, 18-0-0 1 4) This truss has been designed for a 10.0 psf bottom ch 5) * This truss has been designed for a live load of 20.Op will fit between the bottom chord and any other memb 6) Provide mechanical connection (by others) of truss to 2=433,14--866,10=240. 1-5. Scale = 1:60.9 30 10 11 6 3x5 PLATES GRIP MT20 244/190 Weight: 172 lb FT = 20% BRACING- TOPCHORD Structural wood sheathing directly applied or 6-0-0 oc purlins. BOTCHORD Rigid ceiling directly applied or 6-0-0 oc bracing. WEBS I Row at midpt 6-14 15 except 2=-433(LC 12), 14=-866(LC 12), 1 0=-240(LC 12) it(s) except 2=687(LC 21), 14=1 635(LC 1), 1 0=399(LC 22), or less except when shown. 8, 6-7=-2721773, 7-9=-3761778, 1881281, 10-12=-1 88/281 1614,9-12=-13/307, 6-16=-501/665, , design. 128mph; TCDL--4.2psf; BCDL=3.Opsf; h=12ft; B--59ft; L=36111; eave=5ft; Cat. -C Exterior(2) -1-0-0 to 2-7-3, Interior(l) 2-7-3 to 18-0-0, Exterior(2) 18-0-0 to reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 n left end, supported at two points, 6-0-0 apart. I live load nonconcurrent with any other live loads. on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide ;, with BCDL = 10.0psf. aring plate capable of withstanding 100 lb uplift at joint(s) 15 except at=lb) Walter P. Finn PE No.22839 Mi rek USA, Inc. Fl. Cent 6634 6904 Parke East Blvd. Tampa Fl. 33610 Date: March 22,2018 WARNING - Verily design p.rariilersndREW NOTES ON THIS ANDINGLUDED MITEK REFERANCE PAGE Mll-7473 rev. 101=015 BEFORE USE. Design valid for use only with MiTekO connectors. This desigrl Is based only upon parameters shown. and Is for an Individual building component not Val' a truss system. Before use, the building designer must verify the applicability of design parameters and properly Incorporate this design Into file overall building design. Bracing Indicated Is to prevent buckling ofilridividual truss web and/or chord members only. Additional temporary and permanent bracing MiTek* Is always required for stability and to prevent collapse with possible personal Injury and property damage. For general guidance regarding the fabrication, storage, delivery. erection and bracing of trusses and truss systems, sceANSI/IPI I Quality Criteria, DSB-89 and RCSI Building Component 6904 Parke East Blvd. Safety Information avallable from Truss Plate Institute, 218 N.! Lee Street, Suite 312, Alexandria, VA 22314. Tampa, FL 33610 40b Truss I Truss Type QtY Ply CARLTON 299 T13569620 M11412 BHA COMMON 1 1 1 Job Reference (optional) ; i RAZ — nn-na-nn on in Pa 9 1 Chambers Truss, Inc., Fort Pierce, FL o. i 30 s Iviar I 1 20 18 1 e n us nes, w ID:kFvnsnOwY4l9ZhC�-nM3lc6y]Jgg-IsNTISCca4PVvKEhqOmEmn?CeOgGNYVbSOluLkZYQMz 16-0-0 24-0-0 14 0-0 15-T6% 80-0 2-0 01�1.0f L-0-0 8-0-0 2-0-0 T-0-0 12 36-0-0 �7-00.-' 2--.. 2 S _0_ 41 6-16 .0 B-0-0 .0 8 .0.0 0. Scale: 3116"=I' 5x6 9 12 14 7xi 0 MT1 BHS 5-� 7 16 r, 18 7x10 zz� 1 5 4.00FI-2 T3x61 8 0 3 8 0 17 20 2 21 22 I? 6 27 24 28 26 25 23 0 3X6 11 4x6 6X8 6X8 3x6 11 3X5 3x6 3x6 15-6-0 22-10-15 ?5_10 8 36-0-0 i 10 ::qN0 7-6-0 7-4-15 8-0-0 Plate Offsets (X,Y)-- [2:0-0-2,Edqel,13:0-3-8,Ec�qel.fll:0-8-0,0-3-01,[20:0-3-8,Edgel,[21:0-2-8,Edgel,[25:0-3-8,0-3-01 LOADING (psf) SPACING- 2-0-0 CS1. DEFL. in (loc) I/def] Ud PLATES GRIP TCLL 20.0 Plate Grip DOL 1.25 TC 0.73 Vert(LL) -0.1428-31 >999 360 MT20 244/190 TCDL 7.0 Lumber DOL 1.25 BG 0.56 Vert(CT) -0.25 23-34 >619 240 MT18HS 244/190 BCLL 0.0 Rep Stress Incr NO WB 0.83 Horz(CT) 0.04 21 n1a. n/a BCDL 10.0 Code FBC2017rrPI2014 Matr1x­MS Wind(LL) 0.20 28-31 >909 240 1 Weight: 208 Ib FT = 20% LIUMBER- BRACING - TOP CHORD 2x4 SP M 30 TOPCHORD Structural wood sheathing directly applied or 4-2-12 oc purlins. BOTCHORD 2x4 SP M 30 BOTCHORD Rigid ceiling directly applied or 6-0-0 oc bracing. WEBS 2x4 SP No.3 WEBS 1 Row at micipt 20-25 2 Rows at 1/3 pis 3-26 JOINTS I Brace at Jt(s): 8, 4,14,16, 18 REACTIONS. All bearings 0-8-0 except at=length) 25=0 11-5 (lb) - Max Horz 2=-208(LC 6) 1) MaxUplift All uplift 100 lb or less at joint(, except 2=-583(LO 8), 26=-1 557(LC 8), 25=-1 259(LC 8), 21 =-455(LC 8) MaxGrav All reactions 250 lb orless atj.lint(s) except 2=983(LC 13), 26=2911(LC 13), 25=2457(LC 14), 21 =757(LC 14) FORCES. (lb) -Max. Comp./Max. Ten. -All forces 250 QD) or less except when shown. TOPCHORD 2-3�2242/1142, 20-21=-1473/724,3-4=112131716, 4-6=-213/718, 6-8=-213f718, 8-1 0=-213171 8, 10-11 =-2131718,11-13='�213f7l8,l3-15=-2131718,15-17�213/718, 17-19=-87/610, 19-20=-87/610, 3-5=-1 991422, 5-7�1 12/391, 7-9=-33/344,12-14=0/257, 16-18=-67/301,18-20=-208/363 I BOTCHORD 2-28=-971/2236, 26-28=-922/2090, 25-�6­855/521, 23-25=-516/1204, 21-23=-569/1344 WEBS 8-26=-1333/1008,17-25=-979/75(3, 3-A=-419/1254, 3-26=-3236/1698, 20-23=-458/1210, 20-25�2385/1201, 9-10=-706/56l), 6-7�-307/2411, 15-16=-462/372,18-19-497/418 NOTES- 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-10; Vuft=1 65mph (3-second gust) Vasd=1 28mph; TCDL=4.2psf; BCDL=3.Opsf; h=1 2ft; B=59ft; L--36ft; eave=5ft; Cat. 11; Exp C; Encl., GCpi=0.18; MWFRS (directional); Lunriber DOL=1.60 plate grip, DOL=1.60 3) Provide adequate drainage to prevent water ponding. i 4) All plates are MT20 plates unless otherwise indicated) 5) All plates are 3x4 MT20 unless otherwise Indicated. 1 6) This truss has been designed for a 10.0 psf bottom ci�ord live load nonconcurrent with any other live loads. 7) * This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other mem6ers. 8) Provide mechanical connection (by others) of truss to I bearing plate capable of withstanding 583 lb uplift at joint 2, 1557 lb uplift at joint 26, 1259 lb uplift at joint 25 and 455 lb uplift at j6int 21. 9) Girder carries hip end with 8-0-0 end setback. 10) Graphical purlin representation does not depict the size or the orientation of the purlin along the top and/or bottom chord. Walter P. Finn PE No.22839 I 11) Hanger(s) or other connection device(s) shall be provided sufficient to support concentrated load(s) 967 lb down and 461 lb up at 28-0-0, and 967 lb down and 461 lb up at 8-0-0 on [bottom chord. The design/selection of such connection device(s) is the Mirek USA, Inc.FL Cert6634 6904 Parke East Blvd. Tampa FL 33610 responsibility of others. Date: 12) In the LOAD CASE(S) section, loads applied to the,'face of the truss are noted as front (F) or back (B). March 22,2018 WARNING - Verify design parameters and READ NOTES ON THIS AND INCL.UDED MITEK REFERANCE PAGE M11-7473 rev. 1010312015 BEFORE USE. Design valid for use only with MITek8 connectors. This deslbn is based only upon parameters shown, and Is for an Individual building component, no, a truss system. Before use, the building designer must verily the applicability of design parameters and properly Incorporate this design Into the overall building design. Bracing Indicated Is to buckling Individual lruss web and/or chord members only. Addiflonal temporary and permanent bracing MiTeW prevent pf Is always required for stability and to prevent collapse with possible personal Injuxy and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of lru�ses and truss systems. seeANSI/TPI I Quality Ciriteria, DSB-89 and BCSI Building Component 6904 Parke East Blvd. Safety information available from Truss Plate Institute, 218 IN. Lee Street, Suite 312. Alexandria, VA 22314. Tampa, FL 33610 Job Truss Truss ype, Qty Ply CARLTON 299 i T13569620 M11412 BHA COMMON. 1 1 Job Reference (optional) An non! nn! 0 0 ^ 0 Chambers I russ, Inc., t--ort Flierce, t-L D—u . i 1 H U� . , . ID:kFvnsnOwY4l9ZhO-nM3lc6y[Jgg-V3xrzoDELOXMXUptOSHTJ_YNOQVV6?8kg21 SuAZYQmy LOAD CASE(S) Standard I 1) Dead + Roof Live (balanced): Lumber Increase=1.25, Plate Increase=1.25 Uniform Loads (plf) I Vert: 1-3=-54, 20-22=-54, 28-29=-20, 23-28=47(17=-�7), 23-32=-20, 3-12=-126(F=-79-),12-20=-126(F=-72) Concentrated Loads (lb) Vert: 26=-641 (F) 23=-641 (F) WARNING - Verity deslqn parameters and READ NOTES ON THISAND INCLUDED MITEKREFERANCE PAGE 11,111-7473 rev. 1010312015 BEFORE USE. Design valid for use only with I'villek:0 connectors.iThis design Is based only upon parameters shown, and Is for an Individual building component, not a IRW system. Before use, the building designer must verify the applicability of design parameters and properly Incorporate this design Into the overall building design. Bracing Indicated Is to prevent buckling of Individual Iruss web and/or chord members only. Additional temporary and permanent bracing MiTek' Is always required for stability and to prevent collapse with posslNe personal Injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems. seeANSI/TPI I Quality Criteria, DSB-89 and 8CS1 Building Component 6904 Parke East Blvd. Safety Information available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandra. VA 22314. Tampa, FL 33610 Job Trus Truss Typ� a ty P ly CARLTON 299 T13569621 M11412 GRA HIP Job Refer Phambers Truss, Inc., Fort Pierce, FL 8.130 s Mar 112018 MiTek industries, Inc. Thu Mar 22 09:08.02 2018 Page I ID:kFvnsnOwY4lgZhO-�nM3lc6ylJgg-zFVDA8Es6ifD9eO4xppirC5YMqocrRHuvin?oczYQmx 7-10-0 -0 8-00 ? _2-4-0 ? -g-o 1 36-0-0 37-0- q -A-OO 7-10-0 tl�20-6 ; 1 14-4— 4_4_0 52M 7-10-0 1-0-0 4.00 F1 —2 6 5x8 MT18HS = 5xB MT1 8HS = 3x4 11 5X8 = 3x4 11 A -- -- - -- a__ -- -1 -- -- 7 Scale = 1:61.9 It !�2 I" IC6 6 LOADING (psf) TCLL 20.0 TCDL 7.0 BCLL 0.0 BCDL 10.0 SPACING- 2-0-0 Plate Grip DOL 1.25 Lumber DOL 1.25 Rep Stress Incr NO Code FBC2017/TP12014 cSI. TC 0.71 BC 0.76 WB 0.84 Matrix -MS DEFL. in (loc) Well Ud Vert(LL) -0.21 12-13 >999 360 Vert(CT) -0.44 12-13 >609 240 Horz(CT) 0.06 8 n1a n/a Wind(LL) 0.22 10-21 >999 240 PLATES GRIP MT20 244/190 MT18HS 244/190 Weight: 161 lb FT = 20% LUMBER- BRACING- TOPCHORD 2X4 SP M 30 TOPCHORD Structural wood sheathing directly applied or 3-4-6 oc purlins. BOTCHORD 2x4 SP M 30 BOTCHORD Rigid ceiling directly applied or 5-7-0 oc bracing. WEBS 2x4 SP No.3 *Except* WEBS 1 Row at micipt 3-13,5-13 4-13,6-12:2x6 SP No.2 REACTIONS. (lb/size) 2=398/0-8-0,13=3546/0-t5-u,5=1252/0-8-0 Max Horz 2=-97(LC 6) 1 Max Uplift 2=-292(LC 8),13�2107(1-13 8), 8=-799(LC 8) Max Grav 2=417(LC 17),13=3546(ILC 1 JJ, 8=1256(LC 18) 1 FORCES. (lb) - Max. Comp./Ma)L Ten. - All forces 250 (lb) or less except when shown. TOPCHORD 2-3=-369/211, 3-4=-1 158/2051, 4-5=-1 �158/2051, 5-6=-2318/1425, 6-7=-231811425, 1 7-8=-29B1/1789 I BOTCHORD 2-15=-196/311,13-15�201/342,12-13=-246/452,10-12=-1588/2818. 8-10=-1578/2786 WEBS 3-15=-181/648,3-13=-2568/1568, 4-1�=-640/587,5-13=-2900/1855,5-12=-1172/2196, 6-12=-6111569, 7-12=-558/375, 7-1 0=_1 84/651 NOTES- 1) Unbalanced roof live loads have been considered f6r this design. 2) Wind: ASCE 7-10; Vult=165mph (3-second gust) Vasd=128mph; TCDL=4.2psf; BCDL=3.Opsf; h=12ft; B=59ft; L=36ft; eave=5ft; Cat. 11; Exp C; Encl., GCpi=O.l 8; MW FRS (directional); L1 umber DOL=1.60 plate grip DOL=1.60 3) Provide adequate drainage to prevent water pondin'g. 4) All plates are MT20 plates unless otherwise indlcat�d. 5) This truss has been designed for a 10.0 psf bottom�. chord live load nonconcurrent with any other live loads. 6) * This truss has been designed for a live load of 20.OpSf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other melnibers. 7) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 292 lb uplift at joint 2, 2107 lb uplift at joint 13 and 799 lb uplift at joint 8. 8) Hanger(s) or other connection device(s) shall be provided sufficient to support concentrated load(s) 137 lb down and 301 lb up at 7-10-0, 103 lb down and 170 lb up at 10-0-12, 103 Ill down and 170 lb up at 12-0-12,103 lb down and 170 lb up at 14-0-12,103 lb down and 170 lb up at 16-0-12,103 lb down and .170 lb up at 18-0-12, 103 lb down and 170 lb up at 19-11-4,103 Ill down and 170 lb up at 21-11-4, 103 lb down and 170 lb up at 23-11-4, and 103 lb down and 170 lb up at 25-11-4, and 137 lb down and 301 lb up at 28-2-0 on top chord, and 340 lb down and 223. lb up at 7-10-0, 77 lb down and 1 Ill up at 8-0-12, 77 lb down and 1 lb up at 10-0-12, 77 lb down and 1 lb up at 12-0-12, 77 lb down and I lb up at 14-0-12, 77 lb down and 1 lb up at 16-0-12, 77 lb down and 1 lb up at 18-0-12, 77 lb down and I lb up at 19�1 1-4, 77 lb down and I lb up at 21-11-4, 77 lb down and I lb up at 23-11-4, 77 lb Walter P. Finn PE No.22839 down and I lb up at 25-11-4, and 77 lb down and 1 lb up at 27-11-4, and 340 lb down and 223 lb up at 28-2-0 on bottom chord. MiTek USA, Inc. FL Cert 6634 The design/selection of such connection device(s) is the responsibility of others. 6904 Parke East Blvd. Tampa FL 33610 9) In the LOAD CASE(S) section, loads applied to I : he face of the truss are noted as front (F) or back (B). Date: LOAD CASE(S) Standard March 22,2018 tini inrl nn nnrip 9 WARNING- Verity design parameter. and READ—E. — I — AWINCLUDED MITEK REFERANCE PAGE M17-7473 rev. 10103)2015 BEFORE USE. Design valid for use only wIfh MffekO connectors. 1W design Is based only upon parameters shown, and Is for cin Individual building component not DOI' a truss system. Before use, the building designer must verify the applicability of design parameters and properly Incorporate this design Into the overall building design. Bracing Indicated Is to prevent buckling of Individual truss web and/or chord members only. Additional temporary and permanent bracing Is always required for stability and to prevent collopso with possible personal Injury and property damage. For general guidance regarding the iWiTeW fabrication, storage. delivery. erection and bracing of trusses and truss systems, seeANSI/TP1 1 Quality Criteria, DSB-89 and BCS1 Building Component 6904 Parke East Blvd. Safety Information available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314. Tampa, FL 33610 Job Trus Truss Typb QtY Ply ARLTON 299 T13569621 M 11412 GRA HIP 1 1 Job Reference (optional) Chambers Truss, Inc., Fort Pierce, FL 8.130 s Mar 112018 MiTeK industries, Inc. Thu Mar 22 09:08:02 2018 Page 2 ID:kFvnsnOwY4l9ZhO—nM3lc6ylJgg-zFVDABEs6ifDgeO4xppirC5YMqocrRHuvin?aczYQmx LOAD CASE(S) Standard 1) Dead + Roof Live (balanced): Lumber Increase=1.25, Plate I ncrease=1.25 Uniform Loads (plf) Vert: 1-3=-54, 3-7=-54, 7-9=-54, 16-19=-20 Concentrated Loads (lb) Vert: 3=-137(B) 5=-103(B) 7=-137(B) 14=-49(B) 15=-389(B) 1 0=-389(B) 1 1�49(B) 22=-103(B) 24=-103(B) 26�103(13) 27=-103(B) 28=-103(B) 29=-103(B) 31=-103(B) 33=-103(B) 34=-49(B) 35=-49(B) 36=-49(B) 37=-49(B) 38=-49(B) 39=-49(B) 40=-49(B) WARNING - Verity design parameters and READ NO TES ON THIS AND INCLUDED mrrEK REFERANCE PAGE M11-7473 rev. 1010312015 BEFORE USE Design valld for use only with MITek0 connectors. This design Is based only upon parameters shown. and Is for a) Individual building component not a truss system. Before use, the building designer must verity the applicability of design parameters and property Incorporate this design Into the overall building design. Bracing Indicated Is to prevent bLickling of Individual truss web and/or chord members only. Additional ternporaW and permanent bracing M!Tek' Is always required for stability and to prevent collabse,,Ath possible personal Injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems. seeANSI/TPI I Quality Criteria, DSB-89 and BCSI Building Component 6904 Parke East Blvd. Safety Information avdloble from Truss Plate Institute. 218 N. Lee Street, Suite 312. Alexandria, VA 22314. Tampa, Fl- 33610 4ob Trus Truss yp� aty Ply CARLTON 99 T13569622 M11412 J2 MONO TRUSS I Job Reference (optional) Chambers Truss, Inc., Fort Pierce, FL 8.130 s Mar 11 2018 Mi I eK industries, Inc. Thu Mar 22 Ou:08:02 2018 Page i ID:kFvnsnOwY4lgZhO—nM3lc6ylJgg-zFVDABEs6ifD9eO4xppirC5hkqyNreLuvin?QczYQmx -1-0-0 2-0-0 1-0-0 2-0-0 Scale = 1:7.8 4.00FI-2 '2 6 3x4 = 2-0-0 LOADING (psf) SPACING- 2-0-0 CS1. DEFL. In (loc) I/defl Ud PLATES GRIP TCLL 20.0 Plate Grip DOL 1.25 TC 0.18 Vert(LL) -0.00 7 >999 360 MT20 - 244/190 TCDL 7.0 Lumber DOL 1.25 BC 0.07 Vert(CT) -0.00 7 >999 240 BCLL 0.0 Rep Stress Incr YES WB 0.00 Horz(CT) -0.00 3 n1a rita BCDL 10.0 Code FBC2017/TP12014 Matflx-MP Wind(LL) 0.00 7 >999 240 Weight: 8 lb FT = 20% LUMBER- BRACING- TOPCHORD 2x4 SP No.3 TOPCHORD Structural wood sheathing directly applied or 2-0-0 oc purlins. BOTCHORD 2x4 SP No.3 BOTCHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS. (lb/size) 3=37/Mechanical,2=141/0-8-�,4=22/MechanicaI Max Harz 2=67(LC 12) Max Uplift 3=-27(LC 12), 2=-1 36(LC 12� 4=-3(LC 9) Max Grav 3=40(LC 17), 2=141 (LC 1), 4=31 (LC 3) FORCES. (lb) -Max. Comp./Max. Ten. -All forces 250 k1b) or ILst; except when shown. NOTES- 1) Wind: ASCE 7-10; Vult=165mph (3-second gust) Vasd=128mph; TCDL=4.2psf; BCDL=3.Opsf; h=12ft; B=59ft; L=36ft; eave=5ft; Cat. 11; Exp C; Encl., GCpi--0.18; MWFRS (directional) anid C-C Exterlor(2) zone;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 ; 2) This truss has been designed for a 10.0 psf bottom �chord live load nonconcurrent with any other live loads. 3) * This truss has been designed for a live load of 20!Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will tit between the bottom chord and any other members. 4) Refer to girder(s) for truss to truss connections. 5) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 27 lb uplift at joint 3, 136 lb uplift at joint 2 and 3 lb uplift at joint 4. 1 Walter P. Finn PE No.22839 MiTek USA, Inc. Fl. Cert 6634 6904 Parke East Blvd. Tampa Fl. 33610 Date: March 22,2018 A WARNING - Verify design parameters and RE4DfflOTES ON THIS AND INCLUDED MITEKREFERANCE PAGE M11­7473 rev. 1010312015 BEFORE USE Design valid for use only with maeke connectors. T�s design Is based only upon parameters shown. and Is for an Individual building component not a truss system. Before use. the building designer must verify the applicability of design parameters and properly Incorporate this design Into ]he overall building design. Bracing Indicated Is to prevent buckling of Individual truss web and/or chord members only. Additional temporary and permanent bracing Is always required for stability and to prevent collabse wilh possible personal Injury and property damage. For general guidance regarding the MiTek' fabrication, storage, delivery, erection and bracing of trusses and truss systems, seeANSI/TPI I Quality Criteria, DSB-89 and BCSI Building Component 6904 Parke East Blvd. Safety Information available from Truss Plate Institute. 218 N. Lee Street, Suite 312, Alexandria, VA 22314. Tampa, FL 33610 ,job Truss Truss Typ 6 city Ply CARLTON 299 1 T13669623 M11412 J4 MONO T Russ I Job Reference (optional) .Chambers Truss, Inc., Fort Pierce, FL 8. i 30 5 IV]d[ i i 2Cj 18 IVII I UR 11 1UUW11GG, 1116. 1 1 IU [Viar � V : : Uu I D:kFvnsnOwY4l9ZhC�-nM3lc6ylJ9g-RR3cOU EUt?n4mozGVWKxOPdpOEEya5b 1 BMWYy3zYQmw --"0-0' 4-0-0 4-0-0 Scale = 1: 11. 1 ;Ixq LOADING (pso SPACING- 2-o-6 CS1. DEFL. in (loc) I/deff Ud PLATES GRIP TCLL 20.0 Plate Grip DOL 1.216 TC 0.37 Vert(LL) -0.01 4-7 >999 360 MT20 244/190 TCDI- 7.0 Lumber DOL 1.25 BC 0.37 Vert(CT) -0.02 4-7 >999 240 BCLL 0 Rep Stress Incr YES WB 0.00 Horz(CT) -0.00 3 n/a n/a BCDL 10 Code FBC20117/TP1201 1 4) Matrix -MP Wind(LL) 0.02 4-7 >999 240 Weight: 14 Ib FT = 20% LUMEIER- TOPCHORD 2x4 SP No.3 BOTCHORD 2x4 SP No.3 REACTIONS. (lb/size) 3=87/Mechanicai, 2=204IO-8-0, 4=49/Mechanical Max Harz 2=102(LC 12) 1 Max Uplift 3=-77(LC 12),2=-1 bVkLU I;e), 4=-/kLC 12) Max Grav 3=91 (LC 17), 2=204(LC11), 4=67(LC 3) BRACING- TOPCHORD Structural wood sheathing directly applied or 4-0-0 oc puffins. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. FORCES. (115) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. NOTES- 1) Wind: ASCE 7-10; Vult=165mph (3-second gust) Vasd=128mph; TCDL--4.2psf; BCDL=3.Opsf; h=12ft; B--59ft; L=36ft; eave=5ft; Cat. 11; Exp C; Encl., GCpi=0.18; IMWFRS (directionial) and C-C Exterior(2) -1-0-0 to 2-7-3, Interior(l) 2-7-3 to 3-10-4 zone;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 2) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 3) * This truss has been designed for a live load I �of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 4) Refer to girder(s) for truss to truss connections. 5) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 77 lb uplift at joint 3, 159 lb uplift at joint 2 and 7 lb uplift at joint 4. Walter P. Finn PE No.22839 MiTek USA, Inc. Fl. Cert 6634 6904 Parke East Blvd. Tampa Fl. 33610 Date: March 22,2018 ,& WARNING- Verify dasign parameters andIREAD NOTES ON THIS AND INCLUDED MITEKREFERANCE PAGE Mll-7473 rev. 1010312015 BEFORE USE. Design valid for use only with MiTek(5) connectors. This design Is based only upon parameters shown, and Is for an Individual building component. not a truss system. Before use, the building designer must ve4ty the applicability of design parameters and properly Incorporate this design Into the overall building design. Bracing Indicated Is to prevent buckling of Individual truss web and/or chord members only. Additional temporary and permanent bracing MiTeW Is always required for stability and to pre�ent collapse with possible personal injury and property damage. For general guidance regarding the fabricaffort, storage, dellvery� erection a6d bracing of trusses and truss systems, seeANSI/TPI I Quality Criteria, DSB-89 and BCSI BuIlding Component 6904 Parke East Blvd. Safety Information available from Truss Plate Institute, 218 N. Lee Street. Suite 312, Alexandria, VA 22314. 1 Tampa, FL 33610 4ob Truss Truss ype Qpy ply CARLTON 299 T13569624 M11412 J6 MONO TRUSS 8 Job Reference (optional) K A - A ­40 D� � I �.;narrlt)ers truss, mc., MR rie[UL, rL ... ... ID:kFvnsnOwy4l9ZhO—nM3lc6ylJgg-wec—bqF6eJvxOyYS3DrAwdA VeSsJYrBMOG6UVzYQMV �'___0000 6-0-0 6-0-0 Scale = 1:14.3 1' 1 6-0-0 6-0-0 LOADING (pso SPACING- 2-070 CS1. DEFL. in (loc) I/defl Ud PLATES GRIP TCLL 20.0 Plate Grip DOL 1.25 TC 0.35 Vert(LL) -0.05 4-7 >999 360 MT20 2441190 TCDL 7.0 Lumber DOL 1.�5 BC 0.83 Vert(CT) -0.11 4-7 >652 240 BCLL 0.0 Rep Stress Incr YES WB 0.00 Horz(CT) -0.00 3 n1a n/a BCDL 10.0 Code FBC2017/TP120P4 Matrix -MP Wind(LL) 0.11 4-7 >639 240 Weight: 20 lb FT = 20% LUMBER- BRACING - TOP CHORD 2X4 SP M 30 TOPCHORD Structural wood sheathing directly applied or 6-0-0 oc pudins. BOTCHORD 2x4 SP No.3 BOTCHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS. (lb/size) 3=14LI/Mechanical, 2=275/0-8-0, 4=70/Mechanical Max Horz 2=140(LC 12) 1 Max Uplift 3=-1 29(LC 12), 2=-1 92(LC 12), 4�8([_C 12) Max Grav 3=1 48(LC 17), 2=275( 1 LC 1), 4=1 OO(LC 3) FORCES. (lb) -Max. Comp./Max. Ten. -All forces 250 (lb) or less except when shown. NOTES- 1) Wind: ASIDE 7-10; Vult=l 65Mph (3-second 11; Exp C; Encl., GCpi--0.18; MWFRS (direc: members and forces & MWFRS for reactior 2) This truss has been designed for a 10.0 psf 3) * This truss has been designed for a live JoE will fit between the bottom chord and any ol 4) Refer to girder(s) for truss to truss connecti 5) Provide mechanical connection (by others) i I joint 2 and 8 lb uplift at joint 4. 1 ist) Vasd=1 28m�h; TCDL=4.2psf; BCDL=3.Opsf; h=1 2ft; B=59ft; L=36ft; eave=5ft; Cat. nal) and C-C Extedor(2) -1 -0-0 to 2-7-3, Interior(l) 2-7-3 to 5-10-4 zone;C-C for shown; Lumber DOL=1.60 plate grip DOL=1.60 :ottom chord live load nonconcurrent with any other live loads. of 20.OpSf on the bottom chord In all areas where a rectangle 3-6-0 tall by 2-0-0 wide ir members. of truss to bearing plate capable of withstanding 129 lb uplift at joint 3, 192 lb uplift at Walter P. Finn PE No.22839 MjTek USA, Inc. Fl. Carl 6634 6SO4 Parke East Blvd. Tampa FL 33610 Date: March 22,2018 WARNING- Verify delgnparamefe,.��d READ NOTES ON THIS ANDINcLuDED&TrEKREFERANCE PAGE M11-7473re, 1010312015 BEFORE USE. Design vdld for use only with MITekS connectors. Ihis design Is based only upon parameters shown. and Is for an Individual building component. not a truss system, Before use. the bulidind designer must verify the applicablIlly of design parameters and properly Incorporate this design Into the overall bullding design. Bracing Indicated Is to buckling of Individual truss web and/or chord members only. Additional temporary and permanent bracing WeW prevent Is always rectUred for stablIlly and to prevent collapse will) possible personal Injury and property damage. For general guidance regardIng the 6904 Parke East Blvd. fabrication. storage, delivery, erection and bracing of trusses and truss systems, seeANSI/TPI I Quality Criteria, DSB-89 and BCSI Building Component Tampa, FL 33610 Safety Information available from Tru I ss Plate institute, 218 N. Lee Street. Suite 312, Alexandria, VA 22314. �ob Truss Truss Typ? a py Ply CARLTON 299 T13569625 M11412 J8 MONO T�USS PrRC onal) 4NO . ;-- .-- —, RA— 00 nn-AQ-nA Onlo D,,;; I Phambers Truss, Inc., �-orl Fierce, 1--L 0-0 --11-0-0 1� 1 3x4 ID:kFvnsn0vvY4I�ih'0--n- M,,3-1,c6,y,lJ-g-g,--w,e,,c,�-'bqF . 6eJvxOyYS 3DrA wdAwSeYYJYrBMOG6UVzYQMV Scale = 1: 17.7 LOADING (pSf) SPACING- 2-d-0 CS1. DEFL. in (loc) I/detl Ud PLATES GRIP TCLL 20.0 Plate Grip DOL 1125 TC 0.61 Vert(LL) -0.14 4-7 >676 360 MT20 244/190 TCDL 7.0 Lumber DOL 1�25 BC 0.47 Vert(CT) -0.30 4-7 >31 0 240 BCLL 0.0 Rep Stress Incr YES WB 0.00 Horz(CT) -0.00 3 n1a nta BCDL 10.0 Code FBC2017fTP12dl4 Matrix -MP Wind(LL) 0.26 4-7 >368 240 Weight: 26 lb FT = 20% LLIMEIER- BRACING- TOPCHORD 2X4 SP M 30 TOPCHORD Structural wood sheathing directly applied or 6-0-0 oc purlins. BOTCHORD 2X4 SP M 30 BOTCHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS. (lb/size) 3=188/Mechanical, 2=348/0-8-0,4=99/Mechanical Max Harz 2=178(LC 12) 1 Max Uplift 3=-174(LC 12), 2=-226(LC 12), 4=-13(LC 12) I Max Grav 3=1 95(LC 17), 2=348(LC 1), 4=1 41 (LC 3) FORCES. (lb) - Max. Comp./Max. Ten. - All fo),ces 250 (lb) or less except when shown. NOTES- i 1) Wind: ASCE 7-10; Vult=165mph (3-second bust) Vasd=128mph; TCDL--4.2psf; BCDL=3.Opsf; h=12ft; B=59ft; L=36ft; eave=5ft; Cat. 11; Exp C; Encl., GCpi=0.18; MWFRS (directional) and C-C Extedor(2) -1-0-0 to 2-7-3, Inteflor(l) 2-7-3 to 7-10-4 zone;C-C for members and forces & MWFRS for reactiops shown; Lumber DOL=1.60 plate grip DOL=1.60 2) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 3) * This truss has been designed for a live lo i a)d of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 4) Refer to girder(s) for truss to truss connections. 5) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 174 lb uplift at joint 3, 226 lb uplift at joint 2 and 13 lb uplift at joint 4. Walter P. Finn PE No.22839 MiTek USA, Inc. FL Carl 6634 6904 Parke East Blvd. Tampa FL 33610 Date: hfin re-h 09 ,& INA RIVING - Verify design parameters ! and READ NOTES ON THIS AND INCLUDED MITEKREFERANCE PAGE Mll-7473 rev. 10/03)2015 BEFORE USE. Design valid for use orgy vAh MITek0connectors. Thisdesign Is based only upon parameters shown. and Isfor an Individual building component. not a trusssystem. Before use. the buildirlb designer must verify the applIcabUlly ofdeslgn parometersand property Incorporate this design Into the overall Is to buckling Individual truss web and/or chord members only. Additional temporary and permanent bracing MiTeW building design. Bracing Indicated prevent of Is always required for stability and to'prevent collapse with possible personal Injury and property damage. For general guidance regarding the fabilcation, storage. delivery, erecil6n and bracing of trusses and truss systems, seeANSI/TPI I Qualfly Criteria, DSB-89 and BCSI Building Component 6904 Parke East Blvd. Safety Information available from Truss Plate Institute. 218 N. Lee Street. Suite 312, Alexandra, VA 22314. Tampa, FL 33610 4ob Trus Truss Type City Ply CARLTON 299 T13569626 M11412 JAB MONO TRUSS 11 Job Reference (optional) .L,naMDerS i russ, mc., ME rIURX, rL ID:kFvnsnOwY4lgZhO—nM3lc6y[Jgg-OqAMoAGkPdloO66fdxMPTqi5hlu62?sKbg?fIXZYQmu 7-10-0 7-10-0 2 3X4 = 4.00 F1-2 8 3 4 Scale = 1:17.6 LOADING (psf) SPACING- 2-0710 CS1. DEFL. in (loc) I/defl Ud PLATES GRIP TCLL 20.0 Plate Grip DOL 1.25 TC 0.58 Vert(LL) -0.13 4-7 >721 360 MT20 244/190 TCDL 7.0 Lumber DOL 11.�5 BC 0.45 Vert(CT) -0.28 4-7 >331 240 BCLL 0.0 Rep Stress Incr YES WB 0.00 Horz(CT) -0.00 3 n/a n/a BCDL 10.0 Code FBC2017rrP]2()i,4 Matrix -MP Wind(LL) 0.24 4-7 >392 240 Weight: 26 lb FT = 20% LIUMBER- BRACING- TOPCHORD 2x4 SP M 30 TOPCHORD Structural wood sheathing directly applied or 6-0-0 oc pudins. BOTCHORD 2x4 SP M 30 BOTCHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS. (lb/size) 3=184/Mechanical,2=3,42/0-8-0,4=97/MechanicaI Max Horz 2=175(LC 12) Max Uplift 3=-1 70(LC 12), 2=-223(LC 12), 4=-1 3(LC 12) Max GraV 3=1 91 (LC 17), 2=342((C 1), 4=1 38(LC 3) FORCES. (lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. NOTES- 1) Wind: ASCE 7-10; Vult=165mph (3-second gyst) Vasd=128mph; TCDL--4.2psf; BCDL=3.Opsf; h=12ft; B=59ft; L=36ft; eave=5ft; Cat. 11; Exp, C; Encl., GCpi=0.18; MWFRS (directional) and C-C Exterior(2) -1-0-0 to 2-7-3, Interior(l) 2-7-3 to 7-8-4 zone;C-C for members and forces & MWFRS for reaction6 shown; Lumber DOL=1.60 plate grip DOL=1.60 2) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent With any other live loads. 3) * This truss has been designed for a live loa6 of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 4) Refer to girder(s) for truss to truss connections. 5) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 170 lb uplift at joint 3, 223 lb uplift at joint 2 and 13 lb uplift at joint 4. Walter P. Finn PE No.22839 MiTek USA, Inc. FL Carl 6634 6904 Parke East Blvd. Tampa FL 33610 Date: March 22,2018 I WARMING - Verity design parameters an I d READ NOTES ON THIS AND INCLUDED MffEK REFERANCE PAGE M11-7473 rov. 10/=015 BEFORE USE. Design valld for use only with MiTek(D coknectors. This design Is based only upon parameters shown, and Is for an Individual building component. not a truss system. Before use, the building designer must verify the applicability of design parameters and properly Incorporate this design Into the overall building design. BracIng Indicated Is to prevent buckling of Individual truss web and/or chord members only. Additional temporary and permanent bracing MiTeW Is always required for stability and to prevent collapse with possible personal Injury and property damage. For general guidance regarding the fabricallom storage, delivery; erectionbrid bracing of trusses and truss systems, seeANSVTPI 1 Quality Criteria, DSB-89 and BCSI Building Component 6904 Parke East Blvd. Safety Information available from Truss'Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314. Tampa, FL 33610 4ob Truss Truss Type city Ply CARLTON 299 T13569627 M11412 KJ8 MONO TRUSS 2 Job Refer .Phambers Truss, Inc., Fort Pierce, FIL 8J 30 s [Viar 1 i 20118 Mi i er, inuutstue5, 111u. i Flu lvlaf �4 uw'uo:uu �v lo �age 1 ID:kFvnsnOwY4igZhO—nM3lc6ylJgg-sOkkOWHNAw9fdFhrAeteO2FMER[UnNxUqJICZNzYQmt 7-2-7 11-3-0 7-2-7 4-0-9 1 7-2-7 1 3-10-5 0-2-4 LOADING (psi) SPACING- 2-0110 CS1. DEFL. in (loc) Weil Ud PLATES GRIP TCLL 20.0 Plate Grip DOL 1.25 TC 0.21 Vert(LL) -0.05 6-9 >999 360 MT20 244/190 TCDL 7.0 Lumber DOL 1.�5 BC 0.25 Vert(CT) -0.10 6-9 >999 240 BCLL 0.0 Rep Stress Incr �O WB 0.35 Horz(CT) 0.01 5 n1a n/a BCDL 10.0 Code FBC2017fFP120 i4 Matrix -MS Wind(I-L) -0.04 6-9 >999 240 Weight: 44 Ito FT = 20% LUMBER- BRACING- TOPCHORD 2X4 SP M 30 TOPCHORD BOTCHORD 2X4 SP M 30 BOTCHORD WEBS 2x4 SP No.3 REACTIONS. (lb/size) 4=90/Mechanical,2--46210-11-5,5--406/MechanicaI Max Harz 2=1 78(LC 8) Max Uplift 4=-102(LC 8), 2=-187(LC 8), 5=-116(LC 8) i FORCES. (lb) - Max. Comp./Max. Ten. - All forges 250 (lb) or less except when shown. TOPCHORD 2-3=-866/230 BOTCHORD 2-6=-234/833, 5-6=-234/833 WEBS 3-6--0/287, 3-5=-913/257 Structural wood sheathing directly applied or 6-0-0 oc puffins. Rigid ceiling directly applied or 10-0-0 oc bracing. NOTES- I t 1) Wind: ASCE 7-10; Vult=l 65mph (3-second gust) Vasd=1 28mph; TCDL=4.2psf; BCDL=3.Opsf; h=1 2ft; B=59ft; L--36ft; eave=5ft; Cat. 11; Exp C; Encl., GCpl=0.18; MWFRS (directional); Lumber DOL=1.60 plate grip DOL=1.60 2) This truss has been designed for a 10.0 psti bottom chord live load nonconcurrent with any other live loads. 3) * This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 Wide will fit between the bottom chord and any oiher members. 4) Refer to girder(s) for truss to truss conneciions. 5) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 102 lb uplift at joint 4, 187 lb uplift at joint 2 and 118 lb uplift at joint 5. 1 6) Hanger(s) or other connection device(s) Shall be provided sufficient to support concentrated load(s) 39 lb down and 58 lb up at 2-11-0, 39 lb down and 58 lb up at 2-11 -0, 8 lb down and 101 lb up at 5-8-15, 8 lb down and 101 lb up at 5-8-15, and 42 lb down and 143 lb up at 8-6-14, and 42 lb downiand 143 lb up at 8-6-14 on top chord, and 47 lb down and 28 lb up at 2-11-0, 47 lb down and 28 lb up at 2-11-0, 47 lb down at 5-.8-15, 47 lb down at 5-8-15, and 31 lb down and 14 lb up at 8-6-14, and 31 lb down and 14 lb up at 8-6-14 on bottom chord. The desigrVselection of such connection device(s) Is the responsibility of others. 7) In the LOAD CASE(S) section, loads apoled to the face of the truss are noted as front (F) or back (B). LOAD CASE(S) Standard 1) Dead + Root Live (balanced): Lumber l,ncrease=1.25, Plate Increase=1.25 Uniform Loads (plf) Vert: 1-4=-54, 5-7=-20 Concentrated Loads (lb) Vert: 10=80(F=40, B=40) 11='-2(F=-1, B�1) 12=-83(F�42, B=-42) 13=14(F=7, B=7) 14�20(F=-10, B�10) 15�50(F=-25, B�25) Walter P. Finn PE No.22839 MiTek USA, Inc. FL Cart 6634 6904 Parke East Blvd. Tampa FL 33610 Date: March 22,2018 ,& WARNING - Vedfy d..Ign pra..t. and READ NOTES ON THIS AND INCLUDED MrrEK REFERANCE PAGE 11,111-7473 rev. 1010312015 BEFORE USE Design valld for use only with M]Tek@ connectors. IhIs design is based only upon porameters shown. and Is for an Individual building component. not a truss system. Before use, ]be building designer must vedly the applicability of design parameters and properly Incorporate this design Into the overall building desIgn. Bracing Indicated Is to prevent buckling of Individual truss web and/or chord members only. Additional temporary and permanent bracing MiTek' Is always required for stability and to provent collapse with possible personal Injury and property damage. For general guidance regarding the 6904 Parke East Blvd. fabrication, storage, delivery, erection and bracing of trusses and truss systems, seeANSI/TPI I Quality Criteria. DSB-89 and BCSI Building Component VA 22314. Tampa, FL 33610 Safety Information available from Tru I �s Plate Institute. 218 N. Lee Street. Suite 312, Alexandfla, job Truss Truss Type apy Ply CARLTON 299 �2 T13569628 M11412 KJA8 MONO TRUSS � I Job Reference (ODtiOnal) ,chambers Truss, Inc., Fort Pierce, FIL 8.130 s Mar 11 2018 MiTek Industries, Inc. Thu Mar 22 09:08:06 40 1 o rag ID:kFvnsnOwY4l9ZhO-nM3lc6ylJgg-sOkkOWHNAw9fdFhrAeteO2FMMRInnN6UqJICZNzYQmt 6-10-0 11-0-3 - —100 6-10-0 4-2-3 Scale = 1: 19.9 3x4 = I 3x4 = 6-10-0 1 111-0-3 LOADING (ps ACING- 2-0-0 CS1. DEFL. in (loc) Vdefl Ud PLATES GRIP TOLL 20.9 :Iate Grip DOL 1125 TO 0.20 Vert(LL) 0.06 6-9 >999 240 MT20 244/190 TCDL 7.0 Lumber DOL 11.25 BC 0.23 Vert(CT) -0.08 6-9 >999 240 BCLL 0.0 Rep Stress Incr INO WB 0.34 Horz(CT� 0.01 5 n1a n/a BCDL 10.0 Code FBC2017/TP12014 1 Matrlx-MS - Weight: 43 lb FT = 20% LUMBER- BRACING- TOPCHORD 2x4 SP M 30 TOPCHORD BOTCHORD ?X4 SP M 30 BOTCHORD WEBS 2x4 SP No.3 REACTIONS. (lb/size) 4=106/Mechanical, 2--1447/0-11-5,5=385/Mechanical Max Harz 2=175(LC 8) 1, Max Uplift 4=-107(LC 8), 2=-321 1 i(LC 8), 5=-202(LC 6) FORCES. (1b) - Max. Comp./Max. Ten. - All for i ces 250 (lb) or less except when shown. TOPCHORD 2-3=-846/526 BOTCHORD 2-6=-520/815,5-6=-520/815 WEBS 3-6=0/268, 3-5=-884/565 Structural wood sheathing directly applied or 6-0-0 oc purfins. Rigid ceiling directly applied or 10-0-0 oc bracing. NOTES- 1) Wind: ASCE 7-10; Vult=165mph (3-second gust) Vasd=128mph; TCDL=4.2psf; BCDL=3.Opsf; h=12ft; B=Wt; L--36ft; eave=5ft; Cat. 11; Exp C; Encl., GCpi=0.18; MWFRS (dire�tional); Lumber DOL=1.60 plate grip DOL=1.60 2) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 3) * This truss has been designed for a live l6ad of 20.Opsf on the bottom chord In all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 4) Refer to girder(s) for truss to truss connections. 5) Provide mechanical connection (by otherS) of truss to bearing plate capable of withstanding 107 lb uplift at joint 4, 321 lb uplift at joint 2 and 202 lb uplift at joint 5. 6) Hanger(s) or other connection device(s),shall be provided sufficient to support concentrated load(s) 39 lb down and 58 Ito up at 2-11-0, 39 lb down and 58 lb up at 2-11-0, 8 lb down and 101 lb up at 5-8-15, 8 lb down and 101 lb up at 5-8-15, and 42 lb down and 143 lb up at 8-6-14, and 42 lb down and 143 lb up at 8-6-14 on top chord, and 31 lb up at 2-11-0, 31 lb up at 2-11 -0, 10 lb down and 30 lb up at 5-8-15, 10 lb down and 30 lb up at 5-8-15, and 31 Ib down and 14 lb up at 8-6-14, and 31 lb down and 14 lb up at "-14 on bottom chord. The designtselection of such connection device(s) is the responsibility of others. 7) In the LOAD CASE(S) section, loads applied to the face of the truss are noted as front (F) or back (B). LOAD CASE(S) Standard 1) Dead + Roof Live (balanced): Lumber' Increase=1.25, Plate Increase=1.25 Uniform Loads (plf) Vert: 1-4=-54, 5-7=-20 Concentrated Loads (1b) Vert: 10--80(F=40, B-_40) 1 J=-2(F=-1, B=-1) 12=-83(F�42, B=-42) 13=14(F=7, B=7) 14�20(1`=-1 0, B=-1 0) 15�50(1==-25, B=-25) I Walter P. Finn PE No.22839 MiTek USA, Inc. FL Carl 6634 6904 Parke East Blvd. Tampa Fl. 33610 Date: March 22,2018 WARNING - Verity design paramele�' . and REA 0 NOTES ON THIS AND INCLUDED MITEK REFERANCE PAGE MR-7473 rev. 10/012015 BEFORE USE. Design valid for use only Win MITekG connectors. This design Is based only upon parameters shown, and Is for an Individual building component. not a in= system. Before use, the building designer must verify the applicabHlty of design parameters and properly Incorporate this design Into the overall building design. Bracing Indicated Is to buckling of Individual truss web and/or chord members only. Additional temporary and permanent bracing MiTele prevent Is always required for stability and t6 prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage. dellvery� erection and bracing of trusses and truss systems, seeANSI/TP11 Quality Criteria, DSB-89 and BCS1 Building Component 6904 Parke East Blvd. Safety Information available from Truss Plate Institute, 218 N. Lee Street. Suite 312. Alexandda, VA 22314. Tampa, FL 33610 Symbols PLATE LOCATION AND ORIENTATION 3/�' Center plot e on joint unless x, y offsets are indicated. Dimensions are in ft-in-sixteenths. Apply plates to both sides of truss and fully embed teeth. 0-719, For 4 x 2 orientation, locate plates 0-1/0 from outside edge of truss. This symbol indicates the required direction of slots in connector plates. Plate location details available in MiTek 20/20 software or upon request. PLATE SIZE The first dimension is the plate 4 x 4 width measured perpendicular to slots. Second dimension is the length parallel to slots. LATERAL BRACING LOCATION Indicated by symbol shown and/or t5y­teixflry the -bracing section-of-thg output, Use T or I bracing if indicated. Indicates location where bearings (supports) occur. Icons vary but -reaction section indicates joint number where bearings occur, Min size shown is for crushing only. Industry Standards: ANSI/TP11: National Design Specification for Metal Plate Connected Wood Truss Construction. DSB-89: Design Standard for Bracing, BCSI: Building Component Safety Information, Guide to Good Practice for Handling, Installing & Bracing of Metal Plate Connected Wood Trusses. Numbering System 6-4-8 1 dimensions shown in ft-in-sixteenths I(Drawings not to scale) 2 TOP CHORDS r) Q� 0 R JOINTS ARE GENERALLY NUMBERED/LETTERED CLOCKWISE AROUND THE TRUSS STARTING AT THE JOINT FARTHEST TO THE LEFT. CHORDS AND WEBS ARE IDENTIFIED BY END JOINT NUMBERS/LETTERS. PRODUCT CODE APPROVALS ICC-ES Reports: ESR- 1311, ESR- 1352, ESR 1988 ER-3907, ESR-2362, ESR-1397, ESR-3282 0 a- :2 Trusses are designed for wind loads in the plane of the truss unless otherwise shown. Lumber design values are in accordance with ANSI/TPI-1 section 6.3 These truss designs rely on lumber values established by others. @ 2012 MITek0 All Rights Reserved MiTek Engineering Reference Sheet: Mll-7473 rev. 10/03/2015 A Generd Safety Notes Failure to Follow Could Cause Property Damage or Personal injury 1 . Additional stability bracing for truss system, e.g. diagonal or X-brocing, is always required. See BCSI. 2. Truss bracing must be designed by an engineer, For wide truss spacing, individual lateral braces themselves may require bracing, or alternative Tor I bracing should be considered. 3. Never exceed the design loading shown and never stock materials on Inadequately braced trusses. 4. Provide copies of this truss design to the building designer, erection supervisor, property owner and all other Interested parties. 5. Cut members to bear tightly against each other. 6. Place plates on each face of truss at each joint and embed fully. Knots and wone at joint locations are regulated by ANSI/TPI 1. 7. Design assumes trusses will be suitably protected from the environment In accord with ANSI[TPI 1. 8. Unless otherwise noted, moisture content of lumber shall not exceed 19% at time of fabrication, 9. Unless expressly noted, this design is not applicable for use with fire retardant, preservative treated, or green lumber. 10. Camber is a non-structural consideration and is the responsibility of truss fabricator. General practice Is to comber for dead load deflection. 11. Plate type, size, orientation and location dimensions indicated are minimum plating requirements. 12, Lumber used shall be of the species and size, and In all respects, equal to or better than that specified. 13. Top chords must be sheathed or purlins provided at spacing Indicated on design. 14. Bottom dh-o-rds-require-loteral bracing -at -I 0-ft, spacing — or less, if no ceiling Is installed, unless otherwise noted, 15. Connections not shown are the responsibility of others 16. Do not cut or alter truss member or plate without prior approval of an engineer. 17. Install and load vertically unless Indicated otherwise, 18. Use of green or treated lumber may pose unacceptable environmental, health or performance risks. Consult with project engineer before use. 19, Review all portions of this design (front, back, words and pictures) before use. Reviewing pictures alone is not sufficient. 20. Design assumes manufacture in accordance with ANSI/TPI 1 Quality Criteria.